Range of wafer type butterfly valves incorporating blue epoxy coated ductile iron bodies, zinc coated iron discs and EPDM seats. Maximum working pressure 16.0 bar. Maximum operating temperature 100ºC.
Range of wafer type butterfly valves incorporating blue epoxy coated cast iron bodies and stainless steel discs. Maximum working pressure 16.0 bar. Maximum operating temperature 100°C.
Range of butterfly valves with blue epoxy coated ductile iron bodies, EPDM seat and a stainless steel disc. Maximum working pressure 16.0 bar. Maximum operating temperature 85°C.
Range of temperature and pressure relief valves incorporating a DZR brass body & EPDM membrane. See model for maximum working pressure. Maximum operating temperature 90°C.
Range of wall mounted, concealed, rough in sets with brass bodies. The product is supplied with a separate trim set incorporating a ceramic cartridge headwork with a single lever operating member. Maximum working pressure 10.0 bar. Maximum operating temperature 85°C.
Quarter turn sanitry ball valve incorporating a brass body and ball, EPDM ‘O’-ring and PTFE seat. Maximum working pressure 12.0 bar. Maximum operating temperature 85°C.
Range of lever operating spherical valves incorporating brass bodies, chrome plated brass ball, PTFE seals and NBR ‘O’-rings. Maximum working pressure 16.0 bar. Maximum operating temperature 85°C.
Range of gate valves with blue epoxy resin coated cast iron (DN65-80) or ductile iron (DN100-200) bodies, EPDM coated ductile iron wedge and EPDM gaskets. The valves are operated via a non-rising spindle with a hand wheel operating member. Maximum working pressure 16.0 bar. Cold water use only.
Range of gate valves incorporating ductile iron epoxy coted bodies and with EPDM ‘O’-ring seals and discs. The valves are operated via a non-rising spindle with a hand wheel operating member Maximum working pressure 16.0 bar. Maximum operating temperature 85°C.
Range of gate valves with blue epoxy coated cast iron bodies, cast iron disc encapsulated in EPDM, stainless steel shaft and EPDM gaskets. The valves are operated via a non-rising spindle with a hand wheel operating member. Maximum working pressure 16.0 bar. Maximum operating temperature 85°C.
Range of gate valves with brass bodies, brass wedges and PTFE seals. The valves are operated via a non-rising spindle with a hand wheel operating member. To be used with copper pipe manufactured to EN1057. Maximum working pressure 16.0 bar. Maximum operating temperature 99°C.
Range of cold-water inlet control groups with DZR brass bodies consisting of an in-line, adjustable pressure reducing valve (PRV) (adjustable in the range of 0.8 bar - 6.0 bar, but factory pre-set at 3.0 or 3.5 bar - see model), strainer and a DZR brass bodied pressure relief valve (SRV) (set at 4.75 bar or 6.0 bar - see model). Products also incorporate an approved single check valve cartridge, verified by test (suitable for backflow protection against Fluid Category 2). Maximum supply pressure 16.0 bar. Maximum operating temperature 80°C.
Range of commercial washing machines with flow controlled by solenoid valve and discharged via a type `AB` airgap (verified by test - suitable for backflow protection against fluid category 5). The products are supplied with three ¾” x ¾” BSP (F) double check valve assemblies (suitable for backflow protection against Fluid Category 3) for installation on each inlet prior to a HDPE inlet hose with ¾” x ¾” captive nut end connections. Maximum working pressure 5.7 Bar. Maximum operating temperature 60°C.
Range of commercial dishwashers with flow controlled by a solenoid valve and discharged via a type AB air gap (verified by test - suitable for backflow protection against fluid category 5). Maximum working pressure 4.0 bar. Cold water use only.
Range of magnetic and electrolytic water conditioners with nickel plated copper bodies. Maximum working pressure 10 bar. MagnaScale2 model has a maximum operating temperature of 85°C. ElectroScale 2 models are for cold water use only.
'Electrocoat BP 116'. Factory applied, black coloured bitumen paint. Apply as per manufacturer's technical data sheet, document number 'ECL/TDS/BP116' dated 10th January 2016. Cure for 30 minutes@55°C and then 10 hours@23°C. For use with water up to 60°C. This material is only approved for the curing conditions that appear on the approval. If the cure conditions are varied from those specified on the approval then the material is not covered by the scope of the approval.
‘Karumel EX4412 Blue & Grey’. Factory applied, blue or grey coloured, epoxy resin based powder coating. Apply and cure as per manufacturer’s instructions reference 'PCA-21062901', issued August 2021. For use with water up to 85°C.
'DELTAPrime 2K SF Primer and DELTAShield HP 500 PW Coating'. Factory applied, grey coloured (once mixed), two-component primer (non-water contact primer) and two-component coating (water contact coating). Mix and apply DELTAPrime 2K SF Primer as per Product Data Sheet ‘October 2019-001’. Cure for 2 hours@25°C. Then mix and apply DELTAShield HP 500 PW Coating as per Product Data Sheet ‘190625’. Cure for 1 minute@25°C. For use with water up to 85°C.
'FY-6 (white coloured) & FY-5 (blue coloured)'. Factory applied epoxy powder coatings. Apply and cure as per manufacturer's instructions ‘fyzj2020925 version 1' dated '2020-9-20'. For use with water up to 85°C.
'S-006TG'. Cream coloured, compression moulded GRP panel. For use with water up to 23°C.
'IPF-GRP-H2O'. Off-white/beige coloured GRP/GRV pipe manufactured by filament winding. For use with water up to 60°C.
'IPF-GRP-H2O'. Off-white/beige coloured GRP/GRV pipe manufactured by filament winding. For use with water up to 60°C.
'XIN-6709-01 hose' manufactured from 'GR-PVC 001N' raw material. Single layered, extruded, black coloured PVC hose. For use with water up to 85°C.
'Ultradur® B4300 G6 HR FC Aqua grey 35413 '. Grey coloured, injection moulded PBT material. For use with water up to 65°C.
'Revolve 6402U'. White coloured (translucent), polyethylene material manufactured by rotational moulding. For use with water up to 85°C.
'Al Bassam High Density Polyethylene Underground Water Tank Panel'. Black coloured, blow moulded HDPE tank panel which is available with three or four layers (of the same material). For use with water up to 65°C.
'Al Bassam High Density Polyethylene Aboveground Water Tank Panel'. Blow moulded HDPE tank panel which comprises of four layers and has a black coloured water contact layer, red and black coloured inner layers and white coloured outer (non-water contact) layer. For use with water up to 65°C.
'BKBB-660'. Black coloured LLDPE 'buoyant body' manufactured by rotational moulding. For use with water up to 23°C.
'NORYL™ 731S-701-01-01-00 black coloured, NORYL™ 731S-801-01-01-00 beige coloured, NORYL™ 731S-845-01-01-00 beige coloured & NORYL™ 731S-960-01-01-00 grey coloured'. Injection moulded PPE materials. For use with water up to 85°C
‘0250-35 (50A), 0260-35 (60A), 0270-44 (70A), 0280-22 (80A) and 0290-11 (90A)’. Black coloured, compression moulded EPDM materials. Shore hardness between 50A & 90A. Tested in-radius size 1.0mm. For use with water up to 23°C.
‘5052911193 (50A), 5062911233 (60A), 5072911255 (70A), 5082911184 (80A) and 5092911126 (90A)’. Black coloured, compression moulded EPDM materials. Shore hardness between 50A & 90A. Tested in-radius size 1.0mm. For use with water up to 23°C.
‘EW45, EW50, EW53, EW54, EW54W, EW55, EW60, EW65, EW70, EW75, EW80, EW81 & EW85’. Black coloured, compression moulded EPDM rubber materials. Shore hardness between 45 & 85. Tested in-radius size 1.4mm. For use with water up to 60°C.
'Flomasta 7619J'. Off-white coloured, PTFE paste intended for use as a thread sealant. For use with water up to 23°C.
'Unecol PVC New Age Solvent Cement'. Translucent, colourless (un-pigmented) solvent cement. Apply as per manufacturer's instructions. Cure for 24 hours at 23°C. For use with water up to 65°C. This material is only approved for the curing conditions that appear on the approval. If the cure conditions are varied from those specified on the approval then the material is not covered by the scope of the approval.
'Marfran E DRW HOF 50A & Marfran E DRW HOF 90A'. Pale yellow coloured (transparent), injection moulded TPS-SEBS materials. Shore hardness between 50A & 90A. Tested in-radius size 1.1mm. For use with water up to 60°C.
single hole, single outlet (swivel) combination tap assemblies (various finishes) with a pull-out spray mechanism. Flow is controlled via a ceramic cartridge headwork with a single lever operating member incorporating an infra-red sensor on the swivel arm which operates a solenoid valve. The spout outlet incorporates a plastic aerator and a hand spray mechanism, and the product is supplied with metal backnuts. Maximum working pressure 5.0 Bar. Maximum operating temperature 60°C.
Side entry BS1212-4 (2016) compact type float operated valves for WC flushing cisterns. The inlet incorporates a plastic strainer and flow restrictor. Maximum working pressure 10.0 bar. Cold water use only.
Bottom Entry BS1212-4 (2016) compact type float operated valves for WC flushing cisterns. Incorporates plastic body and ½’’ BSP inlet. The inlet incorporates a plastic strainer and flow restrictor. Maximum working pressure 10.0 bar. Cold water use only.
Bottom entry BS1212-4 (2016) compact type float operated inlet valve for WC flushing cisterns with a plastic body and adjustable float and a plastic flow regulator at the inlet. Maximum working pressure 10.0 bar. Cold water use only.
Concealed WC dual flushing cistern with a BS 1212-4 (2016) float operated inlet valve providing a Type AG air gap arrangement and a dual flush pneumatic outlet valve. The cistern incorporates an angled servicing valve and a stainless-steel braided EPDM lined flexible hose assembly installed prior to the inlet valve. The flush volume is operated by a two-push button assembly for a 6 or 3 litre flush volume. Maximum working pressure 10.0 bar. Cold water use only.
AQUAECO RANGE OF WC flushing cistern incorporating a side entry compact type float operated inlet valve providing a Type AG air gap with a dual flush drop valve for full flush volumes of up to 6 litres and a reduced flush of up to 4 litres. The cistern is operated by a manual push button and incorporates a servicing valve on the inlet supply. Maximum working pressure 10.0 bar. Cold water use only.
AQUAECO WC flushing cistern incorporating a side entry compact type float operated inlet valve providing a Type AG air gap with a dual flush drop valve for full flush volumes of up to 6 litres and a reduced flush of up to 4 litres. The cistern is operated by a manual push button and incorporates a servicing valve on the inlet supply. Maximum working pressure 10.0 bar. Cold water use only.
AQUAECO WC flushing cistern incorporating a side entry compact type float operated inlet valve providing a Type AG air gap with a dual flush drop valve for full flush volumes of up to 6 litres and a reduced flush of up to 4 litres. The cistern is operated by a manual push button and incorporates a servicing valve on the inlet supply. Maximum working pressure 10.0 bar. Cold water use only.
WC flushing cistern incorporating a side entry compact type float operated inlet valve providing a Type AG air gap with a dual flush drop valve for full flush volumes of up to 6 litres and a reduced flush of up to 4 litres. There is a flow restrictor and stainless-steel strainer on the inlet valve. The cistern is operated by a manual push button. Maximum operating pressure 8.0 bar. Cold water use only.
Range of floor mounted, single hole, single outlet (fixed), combination tap assemblies (chromium plated brass), incorporating a ceramic cartridge headwork with a single lever operating member and a manual diverter to shower outlet. The spout has a waterfall outlet. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.
Spring loaded resilient trim, in-line check valve cartridge with plastic guides and stem and EPDM seals within a plastic housing. For insertion into pipes or fittings with specifically dimensioned bores. Maximum working pressure 16.0 bar & maximum operating temperature 65°C.
Type TK, spring loaded resilient trim, in-line check valve cartridge with plastic guides and stem and EPDM seals within a plastic housing. For insertion into pipes or fittings with specifically dimensioned bores. Maximum working pressure 16.0 bar. Maximum operating temperature 85°C.
Type TK, spring loaded resilient trim, in-line check valve cartridge with plastic guides and stem and EPDM seals within a plastic housing. For insertion into pipes or fittings with specifically dimensioned bores. Maximum working pressure 16.0 bar. Maximum operating temperature 85°C.
Type TK, spring loaded resilient trim, in-line check valve cartridge with plastic guides and stem and EPDM seals within a plastic housing. For insertion into pipes or fittings with specifically dimensioned bores. Maximum working pressure 16.0 bar. Maximum operating temperature 85°C.
Type TK, spring loaded resilient trim, in-line check valve cartridge with plastic guides and stem and EPDM seals within a plastic housing. For insertion into pipes or fittings with specifically dimensioned bores. Maximum working pressure 16.0 bar. Maximum operating temperature 85°C
Range of in-line, non-verifiable single check valve assemblies consisting of a spring loaded, resilient trim, single check valve cartridge housed within a DZR brass body (brass or chrome plated). Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.
Range of inline non verifiable double check valve assemblies with DZR brass bodies. Model S0270L-1 incorporates an isolation valve and is chrome plated. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.
Non-metallic materials and components comply with BS6920 at 60°C
‘Calomax Eclipse’ range of electrically heated counter top or wall mounted catering water boilers. The boilers incorporate a stainless steel cold water feed cistern which has a combined vent/overflow fitted with an insect screen. The water to the cistern is supplied via a solenoid valve which incorporates an approved check valve cartridge, however, the complete product has not been fully tested to demonstrate it provides backflow protection. The water level is electronically controlled via level sensors. The water is dispensed via a manually operated brass bodied (chrome plated)/stainless steel bodied self-closing tap(s) or a push button controlling a solenoid valve prior to the outlet. The counter top models are supplied with a PVC coated flexible inlet hose (¾” BSP (F) x 15mm standpipe) and a push fit adaptor (15mm push fit x ¾ BSP (F)). Maximum working pressure 10.0 bar (to the solenoid valve). Maximum temperature of dispsensed water 90°C for PB3C10 & PB3W5 models and 97°C for all other models. Cold water supply only.
Range of single hole, single outlet (fixed spout with a swivel nozzle) over the rim bidet combination tap assemblies (various finishes). The taps incorporate quarter turn ceramic disc headwork with cross top or lever type operating members. The spout outlets have a plastic aerator and the products are supplied with a lever type pop-up waste. Maximum working pressure 5.0 bar Maximum operating temperature 60°C
Headwork assemblies (stainless steel or brass bodies) incorporating a quarter turn ceramic disc with single lever operating member. The outlet incorporates an approved check valve cartridge however, the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum working pressure 10.0 bar. Maximum operating temperature 65°C.
Headwork assemblies (stainless steel or brass bodies) incorporating a quarter turn ceramic disc with single lever operating member. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C
Range of deck mounted, single hole or two hole, single outlet (swivel) combination tap assemblies (chromium plated brass), incorporating one (UMPM-1DLN-00 model only) or two quarter turn ceramic disk headworks with single lever operating members. The product incorporates a hand held pre-rinse spray with a self-closing trigger on a flexible hose within an overhead spring. Models are available with an additional swivel spout outlet, which incorporates a plastic aerator (see model). The swivel spouts have their own flow control in addition to the main headwork, this is also a quarter turn ceramic disk headwork with a single lever operating member. The UMPM-1DLN-00 model is a single feed and comes with an optional ½” NPSM (M) x ½” BSP (F) brass adapter. The UMPM-2DLN-00 model is supplied with two ½” BSP (F) x ½” BSP (M) single check assemblies (suitable for backflow protection against Fluid category 2), for installation on each inlet hose. The inlets on the UMPM-6DLN-00 & UMPM-7DLN- 00 models incorporate an approved check valve cartridge, however the complete product has not been fully tested to demonstrate it provides backflow protection. The product is supplied with metal backnuts. Maximum working pressure 8.62 bar. Maximum operating temperature 60°C.
Range of wall mounted, two hole, single outlet (swivel) combination tap assemblies (chromium plated brass), incorporating quarter turn ceramic disk headworks with single lever operating members. The product incorporates a hand held pre-rinse spray with a self-closing trigger on a flexible hose within an overhead spring. Models are available with an additional swivel spout outlet, which incorporates a plastic aerator (see model). The swivel spouts have their own flow control in addition to the main headwork, this is also a quarter turn ceramic disk headwork with a single lever operating member. The inlets incorporate an approved check valve cartridge, however the complete product has not been fully tested to demonstrate it provides backflow protection. The product is supplied with metal backnuts. Maximum working pressure 8.62 bar. Maximum operating temperature 60°C.
Range of deck mounted, single hole or two hole, single outlet (swivel) combination tap assemblies (chromium plated brass), incorporating one (UMPK-1DLN-00 model only) or two quarter turn ceramic disk headworks with single lever operating members. The product incorporates a hand held pre-rinse spray with a self-closing trigger on a flexible hose within an overhead spring. Models are available with an additional swivel spout outlet, which incorporates a plastic aerator (see model). The swivel spouts have their own flow control in addition to the main headwork, this is also a quarter turn ceramic disk headwork with a single lever operating member. The UMPK-1DLN-00 model is a single feed and comes with an optional ½” NPSM (M) x ½” BSP (F) brass adapter. The UMPK-2DLN-00 model is supplied with two ½” BSP (F) x ½” BSP (M) single check assemblies (suitable for backflow protection against Fluid category 2), for installation on each inlet hose. The inlets on the UMPK-6DLN-00 & UMPK-7DLN-00 models incorporate an approved check valve cartridge, however the complete product has not been fully tested to demonstrate it provides backflow protection. The product is supplied with metal backnuts. Maximum working pressure 8.62 bar. Maximum operating temperature 60°C.
Range of deck mounted, two hole, single outlet (swivel) combination tap assemblies (chromium plated brass), incorporating quarter turn ceramic disk headworks with single lever operating members. The product incorporates a hand held pre-rinse spray with a self-closing trigger, either on a flexible hose within an overhead spring or as a fixed length flexible hose on a swivel arm (see model). Models are available with an additional swivel spout outlet, which incorporates a plastic aerator (see model). The swivel spouts have their own flow control in addition to the main headwork, this is also a quarter turn ceramic disk headwork with a single lever operating member. The inlets incorporate an approved check valve cartridge, however the complete product has not been fully tested to demonstrate it provides backflow protection. The product is supplied with metal backnuts. Maximum working pressure 8.62 bar. Maximum operating temperature 60°C.
Range of deck mounted, single hole (UMPU-1DLN-00 & UMPU-2DLN-00 models) or two hole (UMPU-6DLN-00 & UMPU-7DLN-00 models), single outlet (swivel) combination tap assemblies (chromium plated brass), incorporating one (UMPU-1DLN-00 model only) or two quarter turn ceramic disk headworks with single lever operating members. The product incorporates a hand held pre-rinse spray with a self-closing trigger on a flexible hose within an overhead spring. Models are available with an additional swivel spout outlet, which incorporates a plastic aerator (see model). The swivel spouts have their own flow control in addition to the main headwork, this is also a quarter turn ceramic disk headwork with a single lever operating member. The UMPU-1DLN-00 model is a single feed and comes with an optional ½” NPSM (M) x ½” BSP (F) brass adapter. The UMPU-2DLN-00 model is supplied with two ½” BSP (F) x ½” BSP (M) single check assemblies (suitable for backflow protection against Fluid category 2), for installation on each inlet hose. The inlets on the UMPU-6DLN-00 & UMPU-7DLN-00 models incorporate an approved check valve cartridge, however the complete product has not been fully tested to demonstrate it provides backflow protection. The product is supplied with metal backnuts. Maximum working pressure 8.62 bar. Maximum operating temperature 60°C.
Range of wall mounted, single hole, single outlet (swivel) combination tap assemblies (chromium plated brass), incorporating a quarter turn ceramic disk headwork with a single lever operating member. The product incorporates a hand held pre-rinse spray with a self-closing trigger on a flexible hose within an overhead spring. Models are available with an additional swivel spout outlet, which incorporates a plastic aerator (see model). The swivel spouts have their own flow control in addition to the main headwork, this is also a quarter turn ceramic disk headwork with a single lever operating member. The inlets incorporate an approved check valve cartridge, however the complete product has not been fully tested to demonstrate it provides backflow protection. The product is supplied with metal backnuts. Maximum working pressure 8.62 bar. Maximum operating temperature 60°C.
Range of wall mounted, two hole, single outlet (swivel) combination tap assemblies (chromium plated brass), incorporating quarter turn ceramic disk headworks with single lever operating members. The product incorporates a hand held pre-rinse spray with a self-closing trigger, either on a flexible hose within an overhead spring or as a fixed length flexible hose on a swivel arm (see model). Models are available with an additional swivel spout outlet, which incorporates a plastic aerator (see model). The swivel spouts have their own flow control in addition to the main headwork, this is also a quarter turn ceramic disk headwork with a single lever operating member. Each inlet incorporates an approved check valve cartridge however, the complete product has not been fully tested to demonstrate it provides backflow protection. The product is supplied with plastic backnuts. Maximum working pressure 8.62 bar. Maximum operating temperature 60°C.
Single-hole single outlet (swivel) combination tap assembly (chromium plated brass) incorporating a ceramic cartridge headwork with a single lever operating member and a pull-out spray. The pull-out spray hose is stainless steel braided and has a. The pull-out spray outlet incorporates a button which changes and/or stops the flow of water, a plastic aerator and check valve cartridge however the complete product has not been fully tested to demonstrate it provides backflow protection.
Range of single hole, single outlet (swivel) pull down spray combination tap assemblies (brass bodies - various finishes - see model), incorporating a ceramic cartridge headwork with a single lever operating member. The connection between the body and the spout incorporates an approved check valve cartridge, however the complete product has not been fully tested to demonstrate it provides backflow protection. The outlet incorporates a plastic aerator. The products are supplied with optional ½” BSP (F) x ⅜ BSP (M) brass adaptors and NBR washers for installation on each inlet hose. Maximum working pressure 6.0 bar. Maximum operating temperature 60°C.
Range of single hole, single outlet (fixed) combination tap assemblies (brass or stainless steel body - various finishes), incorporating a ceramic cartridge headwork with a single lever operating member. The spout outlet incorporates a plastic aerator. The HV3 model is supplied with a pop-up waste. Maximum working pressure 5.0 bar. Maximum operating temperature 65 °C.
Single hole, single outlet (fixed) combination tap assembly (chromium plated brass) incorporating a ceramic cartridge headwork with a single lever operating member. The spout outlet incorporates a plastic flow aerator. The AQE-DIP-301-CP model is supplied with a pop-up waste. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.
Range of single hole, single outlet (fixed) combination tap assemblies (chrome plated brass). Incorporating a ceramic cartridge headwork and single lever operating members however model 922034 is fitted with a non rising spindle headwork and dome type operating members. The spout outlet incorporates a plastic flow straightener on models: 922064, 922034, 922302, 922303, 922304 or flow straightener and aerator kit on models: 922311, 922312, 922313, and some models are supplied with a click waste. Maximum working pressure 6.0 bar. Maximum operating temperature 60°C.
Range of single hole, single outlet (fixed) combination tap assemblies incorporating chromium plated brass bodies, ceramic cartridge headwork with single lever operating member. The spout outlets incorporate either a plastic aerator or flow straightener. The 2565T1EP, 2565T3EP & 3565T5EP models are supplied with a check valve cartridge and filter on the inlets, however, the complete product has not been fully tested to demonstrate it provides backflow protection. The 2565T1, 2565T3 & 2565T5 models have flow restrictors on the inlets. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.
Range of single hole, single outlet (fixed) combination tap assemblies (chrome plated brass) incorporating a ceramic cartridge headwork and either cross top or a single lever operating member. The spout outlets incorporate a plastic flow straightener and the products are supplied with lever operated pop-up waste. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.
Range of single hole, single outlet (fixed) combination tap assemblies (various finishes, see models) incorporating a ceramic cartridge headwork with a single lever operating member. The spout outlet incorporates a plastic aerator. The products are supplied with either a lever type waste (model 39 034) or screw down waste (39 037). Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.
Range of single hole, single outlet fixed combination tap assemblies (chrome plated brass), incorporating a ceramic cartridge headwork with a single lever operating member. The spout outlets incorporate a plastic aerator. Maximum operating pressure 10.0 bar. Maximum operating temperature 60°C.
Range of single hole, single outlet fixed combination tap assemblies (chrome plated brass) incorporating a ceramic cartridge headworks with single lever operating member. The spout outlets incorporate a plastic aerator. Model (PM BAS C) is supplied with a lever type pop-up waste. Maximum operating pressure 7.0 bar. Maximum operating temperature 60°C.
Range of single hole, single outlet fixed combination tap assemblies (chrome plated brass), incorporating a ceramic cartridge headwork with single lever operating members. The spout outlets incorporates a plastic aerator. Maximum operating pressure 10.0 bar. Maximum operating temperature 60°C
Range of single hole, single outlet (fixed) combination tap assemblies (chromium plated brass), incorporating ceramic cartridge headworks with single lever operating members. The spout outlets incorporate a plastic aerator. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.
Range of single hole, single outlet (fixed) combination tap assemblies with brass bodies (various finishes). Incorporating a ceramic cartridge headworks, and various operating members. The spout outlet incorporates a flow straightener and is also supplied with an optional aerator. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.
Range of single hole, single outlet (fixed) combination tap assemblies with brass bodies (various finishes). Incorporating a quarter turn ceramic disc headworks, and various operating members. The spout outlet incorporates a flow straightener. Product is supplied with a pop-up waste. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.
Single hole, single outlet (fixed) combination tap assembly (chromium plated brass), incorporating a ceramic cartridge headwork with a single lever operating member. The spout outlet incorporates a plastic aerator. The product is supplied with optional ⅜” BSP (M) x ½” BSP (F) adaptors each with a fibre gasket for installation on each inlet hose. The product is supplied with a pop-up waste. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.
Single hole, single outlet (fixed) combination tap assembly incorporating a ceramic cartridge headwork with a single lever operating member. The spout outlet incorporates a plastic aerator. Maximum working pressure 10.0 Bar. Maximum operating temperature 60°C.
Range of single hole, single outlet (fixed) combination tap assemblies (brass body with various finishes) incorporating ceramic cartridge headworks with single lever operating members. The spout outlets incorporate a plastic aerator and the products are supplied with a pop up waste. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.
Range of single hole, single outlet (swivel) combination tap assembly (chrome plated brass) incorporating quarter turn ceramic disk head works with cross top operating members. The spout outlet incorporates a plastic flow straightener. The products are supplied with click type pop-up waste. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.
Range of single-hole, single outlet (swivel) combination tap assemblies (brass bodies - various finishes - see model), incorporating a ceramic cartridge headwork with a single lever operating member. The spout outlet incorporates a plastic aerator. Maximum working pressure 10.0 bar. Maximum working temperature 60°C.
Range of single hole, single outlet (swivel) combination tap assemblies (various finishes) incorporating quarter turn ceramic disc headworks with cross-top operating members. The inlet hose assemblies incorporate a servicing valve and is supplied with a single check valve assembly verified by test (suitable for backflow protection against Fluid Category 2). The spout outlets incorporate a plastic flow straightener. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C
Range of single hole, single outlet (swivel) combination tap assemblies (chrome plated brass bodies) incorporating quarter turn ceramic disc headwork with cross-top operating members. The inlet hose assemblies incorporate a servicing valve and is supplied with a single check valve assembly verified by test (suitable for backflow protection against Fluid Category 2). The spout outlets incorporate a plastic aerator. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C
Range of single hole, single outlet (swivel) combination tap assemblies with brass bodies (various finishes).Incorporating quarter turn ceramic disc headworks and various operating members. The spout outlet incorporates a flow straightener and is supplied with an optional plastic aerator. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.
Range of single hole, single outlet (swivel) combination tap assemblies with (chrome plated) brass bodies. Incorporating ceramic cartridge headworks and single lever operating members. The spout outlet incorporates a aerator. Inlets incorporate single check valve cartridge (however the the complete assembly has not been tested to demonstrate it provides adequate backflow protection)Maximum working pressure 5.5 bar. Maximum operating temperature 60°C.
Single hole, single outlet (swivel) combination tap assembly (chromium plated brass). Incorporating ceramic cartridge headworks, single lever operating members and pull down spray with pre-rinse trigger mechanism incorporating an approved check valve cartridge (however, the complete product has not been fully tested to demonstrate it provides backflow protection) Both inlet hoses incorporate an approved check valve cartridge (however, the complete product has not been fully tested to demonstrate it provides backflow protection). The outlet incorporates a plastic aerator. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.
Range of single hole, single outlet (swivel) combination tap assemblies (chrome plated brass), incorporating quarter turn ceramic disc headworks. The inlet hose assemblies incorporate a servicing valve and is supplied with a single check valve assembly verified by test (suitable for backflow protection against Fluid Category 2). The spout outlets incorporate a plastic aerator. Maximum working pressure 10.00 bar. Maximum operating temperature 60°C.
Range of two hole, single outlet (fixed) combination tap assembly (chrome plated brass) incorporating a quarter turn ceramic disc headwork with single lever operating members. The spout outlet incorporates a plastic flow straightener. Supplied with metal backnuts. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.
Two hole, single outlet (fixed) combination tap assembly (chrome plated brass) incorporating quarter turn ceramic disc headworks with single lever operating members. The spout outlet incorporates a plastic aerator. The product is supplied with metal back nuts. Maximum working pressure 10.0 bar. Maximum operating temperature 85°C.
Range of wall mounted, two-hole, single outlet (fixed) combination tap assemblies, comprising of a concealed rough in set with a brass body and a variety of separate trim sets incorporating a ceramic cartridge headwork with a single lever operating member and a spout outlet. The spout outlet incorporates a plastic aerator. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.
Range of wall mounted, two-hole, single outlet (fixed) combination tap assemblies, comprising of a concealed rough in set with a brass body and a variety of separate trim sets incorporating a ceramic cartridge headwork with a single lever operating member and a spout outlet. The spout outlet incorporates a plastic aerator. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.
Range of two-hole single outlet fixed combination tap assemblies incorporating brass bodies (variety of finishes) and quarter turn ceramic disc headwork with either cross top or single lever operating members. The spout outlets incorporate a plastic aerator and the products are supplied with metal back nuts. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.
Two hole, single outlet fixed combination tap assembly (chrome plated brass) incorporating quarter turn ceramic disc headworks with single lever operating members. The spout outlet incorporate a plastic flow straightener and the product is supplied with metal back nuts. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.
Wall mounted, two-hole single outlet fixed combination tap assembly (chrome plated brass) incorporating a ceramic cartridge headwork with single lever operating member. The spout outlet incorporates a plastic flow straightener. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.
Two hole, single outlet fixed combination tap assembly (chrome plated brass) incorporating quarter turn ceramic disc headwork with cross-top operating members. The spout outlet incorporates a plastic flow straightener and the product is supplied with metal back nuts. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.
Range of wall mounted two hole, single outlet (fixed) combination tap assemblies with brass bodies (various finishes). Incorporating ceramic cartridge headworks and single lever operating members. The spout outlet incorporates a plastic aerator. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.
Two hole, single outlet (fixed) combination tap incorporating a brass body (chrome plated), quarter turn ceramic disc headworks and EPDM ‘O’-rings. The spout outlet incorporates a plastic flow straightner. Product is supplied with plastic backnuts. Maximum working pressure 10.0 bar. Maximum operating temperature 60ºC.
Range of two hole, single outlet (fixed) combination tap assemblies (chrome plated brass). Incorporating quarter turn ceramic disc headworks and single lever operating members. The spout outlet incorporates either a plastic flow straightener or aerator depending on model. Maximum working pressure 6.0 bar. Maximum operating temperature 60°C.
Range of two hole, single outlet (fixed) combination tap assemblies (chrome plated brass). Incorporating quarter turn ceramic disc headworks and single lever operating members. (Model 922041 incorporates a non-rising spindle headworks with dome type operating members) The spout outlets incorporate either a plastic flow straightener or aerator depending on model. Maximum working pressure 6.0 bar. Maximum operating temperature 60°C.
Range of two hole wall mounted, single outlet (fixed) combination tap assemblies consisting of a concealed brass alloy body incorporating a ceramic cartridge headwork and a chrome finish set (external part) comprising of a face plate, dome type operating member. Spout outlet incorporates a plastic aerator. Maximum working pressure 5.0 bar. Maximum working temperature 60°C.
Range of two hole, metal, single outlet (fixed) combination tap assemblies (chromium plated brass) incorporating quarter turn ceramic disc headworks with single lever operating member and a manual diverter to the shower outlet. The products are supplied with a shower hose and handset. The spout outlet incorporates a plastic aerator. The product is supplied with metal backnuts. Maximum working pressure 10.0 bar. Maximum operating temperature 70°C.
A two-hole single outlet (fixed) combination tap assembly (chromium plated brass), incorporating quarter turn ceramic disc headworks with single lever operating members and a manual diverter to shower outlet. The spout outlet incorporates a plastic flow straightener. This product is supplied with a shower hose and handset and either plastic or metal back nuts. Maximum working pressure 10.0 bar. Maximum working temperature 65°C.
Deck mounted, two-hole, single outlet (fixed) combination tap assembly (chrome plated brass) incorporating a manual diverter to shower with a single lever operating member. Flow is controlled via a ½ turn ceramic disc headworks with cross top operating members. Maximum working pressure 5.0 bar. Maximum operating temperature 60ºC
Two-hole single outlet fixed combination tap assemblies incorporating a brass body (variety of finishes), quarter turn ceramic disc headwork with single lever operating members and manual diverter to shower outlet. The temperature is controlled independently via a thermostatic cartridge with a cross-top operating member. The products are supplied with a flow regulator, shower handset, shower hose and shower head. The spout outlets incorporate a plastic aerator. The inlets of the tap and the outlet of the shower handset incorporate approved check valve cartridges however, the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.
Range of two-hole deck mounted combination tap assemblies incorporating brass bodies (various finishes) and quarter turn ceramic disc headworks with either cross top or single lever operating members. The products incorporate a manual diverter to a shower outlet with a single lever operating member and the spout outlets incorporate plastic aerator. The products are supplied with a shower handset, shower hose and metal back nuts. Maximum working pressure 5 bar. Maximum working temperature 60°C.
Deck mounted, two-hole, single outlet (fixed) combination tap assembly (chromium plated brass) incorporating quarter turn ceramic disc headworks with single lever operating members and a self-cancelling diverter to the shower outlet. The spout outlet incorporates a plastic flow straightener or an optional aerator. The product is supplied with a shower hose, shower handset and metal backnuts. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.
Range of two hole, single outlet (fixed) combination tap assemblies (various finishes). Incorporating quarter turn ceramic disc headworks, cross top operating members and self cancelling diverter to shower outlet. The spout outlet incorporates a plastic aerator. The product is supplied with a shower hose and handset and metal backnuts. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.
Range of two-hole, single outlet (swivel) combination tap assemblies incorporating brass bodies (various finishes) and quarter turn ceramic disc headwork with either single lever or cross top operating members. The spout outlets incorporate a plastic flow straightener and the products are supplied with metal backnuts. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C
Range of two-hole, single outlet (swivel) combination tap assemblies (chrome plated brass) incorporating quarter turn ceramic disc headworks with single lever or dome type operating members. The spout outlets incorporate a plastic flow straightener and the products are supplied with metal backnuts. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.
Two hole, single outlet (swivel) combination tap assembly (various finishes) incorporating quarter turn ceramic disk headwork with cross-top operating members. The inlets incorporate approved single check cartridges however the complete assembly has not been tested to demonstrate it provides back flow prevention. The spout outlet incorporates a plastic flow straightener. The product is supplied with metal back nuts. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.
Range of wall mounted, two hole, single outlet combination tap assembly with brass bodies (chrome or nickel plated finish, see model) incorporating quarter turn ceramic disc headworks, various operating members, a lockable diverter to the shower outlet and a swivel spout. The shower outlet on the main body incorporates an approved check valve cartridge, however, the complete product has not been fully tested to demonstrate it provides backflow protection The spout outlet incorporates a plastic flow straightener, also supplied with an optional areator. The product is supplied with a shower hose and handset and metal backnuts Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.
Range of wall mounted three-hole, single outlet (fixed) combination tap assemblies with brass bodies (various finishes) incorporating quarter turn ceramic disc headwork with either single lever or cross top operating members. The spout outlets incorporate a plastic aerator. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.
Range of three-hole, metal, single outlet (fixed) combination tap assemblies (chrome plated brass)) incorporating quarter turn ceramic disc headworks and either single lever or cross top operating members (see model). The spout outlets incorporates a plastic aerator and the products are supplied with a lever operated pop-up waste. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.
Range of deck mounted, three-hole, single outlet (fixed) combination tap assemblies with brass bodies (various finishes), incorporating quarter turn ceramic disc headworks with various operating members. The headworks are connected to the spout via stainless steel braided, PEX lined flexible hose assemblies. The spout outlets incorporate a plastic flow straightener and the products are supplied with a lever operated pop-up waste. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.
Range of concealed, wall mounted, three hole, single outlet (fixed) combination tap assemblies (various finishes) incorporating quarter turn ceramic disc headwork and cross top operating members. The spout outlets incorporate a plastic aerator. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.
Range of wall mounted three hole, single outlet (swivel) combination tap assemblies with brass bodies (various finishes). Incorporating quarter turn ceramic disc headworks and various operating members. The spout outlet incorporates a plastic flow straighterner and is also supplied with an optional aerator. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.
Range of three hole, single outlet (swivel) combination tap assemblies with brass bodies (various finishes). Incorporating quarter turn ceramic disc headwork and cross top operating members (models RIV6 CHR & RIV6 GOLD) or dome type operating members (all other models). The spout outlet incorporates a plastic flow straightener and is supplied with an aerator. The products are also supplied with TAQ PEX lined flexible connecting hose assemblies, intended for use between sidebody valves and spout. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.
Functional trim set (chrome plated), comprising of a ceramic cartridge headwork with a single lever operating member and a spout outlet. The spout incorporates a plastic flow regulator on the inlet and a plastic aerator on the outlet. Maximum working pressure 10.0 bar. Maximum working temperature 60°C.
Functional trim set (chrome plated), comprising two quarter turn ceramic disc headworks with either single lever (models ending in 882) or cross top (models ending in 892) operating members and a spout outlet. The spout outlet incorporates a plastic aerator. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.
Range of two hole, single outlet (swivel) combination tap assemblies (various finishes). Incorporating quarter turn ceramic disc headworks with various operating members and manually operated diverter to a shower hose and handset. The spout outlet incorporates a plastic flow straightener and is also supplied with an optional aerator. The outlet to the shower incorporates an approved check valve cartridge, however, the complete product has not been fully tested to demonstrate it provides backflow protection. The product is supplied with metal backnuts. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.
Floor mounted, single hole, single outlet (fixed) combination tap assembly (various finishes), incorporating a ceramic cartridge headwork with single lever operating member and a lockable self-cancelling diverter to shower outlet. The spout outlet incorporates a flow straightener or optional aerator. Both the shower outlet (from the main body) and the inlet to the shower handset incorporate Incorporates an approved check valve cartridge, however, the complete product has not been fully tested to demonstrate it provides backflow protection The product is supplied with a shower hose and handset. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.
Range of wall mounted basin spouts (chromium plated brass). The spout incorporates a plastic flow regulator on the inlet and a plastic aerator on the outlet. Maximum operating temperature 60°C.
Wall mounted bath spout outlet incorporating a brass body (chromium plated) and a plastic flow straightener. Maximum operating temperature 60°C.
Range of copper press fittings with EPDM ‘O’-rings for use with EN1057 copper tube. The joints are achieved by means of a press tool. For above and below ground use (sizes 12mm-54mm only. 66.7mm, 76.1mm, 88.9mm & 108mm for above ground use only) Maximum working pressure 16.0 bar. Maximum operating temperature 85°C.
Range of press fit fittings incorporating copper (GP5 models) or bronze (GP4 models) bodies and EPDM `O`-rings, for use with copper tube to EN 1057. For above ground use only. Maximum working pressure 16.0 bar. Maximum operating temperature 85°C.
Unidelta range of compression fittings with polypropylene bodies with EPDM ‘O’ rings for use with PE100 polyethylene pipe (manufactured to EN12201). Maximum working pressure 16.0 bar. Cold water use only.
Range of copper press fittings with EPDM rubber ‘O’-rings for use with copper pipe (manufactured to EN 1057). Maximum working pressure 16.0 bar. Maximum operating temperature 85°C.
Range of water meters with black epoxy coated cast iron bodies. Maximum working pressure 16.0 bar. Maximum operating temperature 50°C.
Range of water meter couplings with black plastic bodies. Maximum working pressure 16.0 bar. Cold water use only
Range of circulation fittings with gun metal bodies, plastic cones & guides and EPDM ‘O’ rings. The products incorporate a dynamic venturi valve. Maximum working pressure 16.0 bar. Maximum operating temperature 65°C.
Copper corrugated hose. Maximum working pressure 10.0 bar. Maximum working temperature 90°C.
Range of multistage pumps incorporating a stainless-steel housing and impellers. Model MHS170 6M has a maximum working pressure of 7.5 bar. Model MHB145 5M has a maximum working pressure of 6.2 bar. Maximum operating temperature 65˚C.
Shower head incorporating brass body (various finishes) and a flow regulator at the inlet. Maximum operating temperature 85°C.
Shower handset with brass body (various finishes). The inlet incorporates a stainless-steel strainer. Maximum operating temperature 65°C.
Range of shower outlets incorporating brass or stainless-steel bodies (various finishes). Maximum operating temperature 65°C.
Range of shower handsets and hoses with either a brass or stainless-steel body (various finishes). Maximum operating temperature 65°C.
Range of PVC lined flexible shower hoses (chrome plated). H21235-1 incorporates a conical and captive nut, H21235-2 incorporates conical nuts. Model:H21235AB added march 2024 Open outlet use only. Maximum operating temperature 60°C.
Range of shower handsets with plastic body (various finishes). The inlet incorporates a single check valve cartridge, however, the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum operating temperature 60°C.
Shower fixing kit for bar shower valves with stainless steel decorative cover. Maximum operating temperature 65°C.
Range of shower kits comprising of a shower hose, shower handset and shower riser. Both models include a plastic bodied, chromium plated, 3 mode shower handset. The ACY1010 model includes a chrome plated stainless steel inter-locked shower hose with EPDM lining. The ACY 1011 model includes a flexible shower hose comprising of a multi-layered hose (silver external appearance) brass end connections, EPDM washers. Maximum operating temperature: ACY1010: 75°C. ACY1011: 60°C.
Range of overhead shower outlets with chromium plated plastic bodies incorporating stainless steel strainers on the inlets. Models 26 724 xxx & 26 727 xxx incorporate a plastic flow regulator on the inlet. Maximum operating temperature 60°C.
Range of wall mounted bib taps (brass bodies) with a rising spindle headwork and ‘T’ type operating member. The spout outlets incorporate a hose union spigot connection. The inlets and outlets of models D2034.G15 and D2034.G20 incorporate an approved check valve cartridge, however the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum working pressure 16.0 bar. Maximum operating temperature 85°C.
Range of bib taps incorporating brass bodies. The S0311BL-1 and S0311BL-2 models incorporate an approved single check valve cartridge on the inlet and the outlet (hose union), however, the complete product has not been fully tested to demonstrate it provides backflow protection. The S0311BL-1 and S0311BL-2 models also incorporate a drain port. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.
Basin pillar tap (chrome plated brass) incorporating quarter turn ceramic disc headwork with single lever operating members. The spout outlet incorporates a plastic flow straightener and the product is supplied with metal backnuts. Maximum working pressure 10.0 bar Maximum operating temperature 60°C.
Range of pillar taps incorporating brass bodies (chrome plated), quarter turn ceramic disc headworks and cross top operating members. Fittings are supplied with metal backnuts. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.
Pillar tap incorporating brass body, quarter turn ceramic disc headwork and EPDM ‘O’-rings. The spout outlet incorporates a plastic flow straightner. Product is supplied with plastic backnuts. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.
Range of self-closing taps (chromium plated brass) incorporating spring loaded headworks with dome type operating members. The spout outlet of the 9000 model incorporates a plastic flow straightener. The products are supplied with a metal back nut. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C, except for the 9054SA model which is cold water use only.
Multi-layer hose incorporating a PVC inner layer and EPDM ‘O’-rings. Maximum operating temperature is 65°C.
Range of TPE and TPS lined flexible hose assemblies incorporating NBR ‘O’-rings and various end connections. Maximum operating temperature 60°C.
Range of shower hoses incorporating stainless steel interlocking outer with PVC inner liner or PVC outer and PVC inner liner (see model). Maximum operating temperature 65°C.
Range of chromium plated stainless steel or brass interlocked shower hoses with an optional PVC outer layer. Incorporating either a PVC or TPE inner hose and EPDM gaskets. Maximum operating temperature 60°C.
‘PARINOX/STRONGFLEX S-200' range of stainless-steel braided EPDM lined flexible hose with various end connections (see model). Compression connections are for use with copper pipe (manufactured to EN1057). Maximum working pressure 10.0 bar. Maximum operating temperature 70°C.
McDonald Steel Flow ranges of Direct, Indirect, Solar Single, Solar Twin, Slim Direct and Slim Indirect stainless steel insulated unvented hot water storage cylinders with external expansion. The DHW circuit consists of a temperature and pressure relief valve set at 7.0 bar and 90°C, an inlet control group consisting of a pressure reducing valve adjustable between 2.7 and 3.3 bar, an expansion relief valve (SRV) set at 6.0 bar, a strainer and a check valve cartridge, verified by test (suitable for backflow protection against Fluid Category 2) also supplied with a tundish. Maximum supply pressure to the inlet control group 10.0 bar. Maximum working pressures - Primary circuit 6.0 bar, Secondary circuit 5.5 bar. Maximum operating temperature 65˚C.
SSB, SSI SST range of stainless steel unvented cylinders provided with an unvented kit supplied with cylinders containing a temperature and pressure reducing valve set at 3.0 bar and an expansion vessel and single check valve (suitable for fluid category 2) . Available as storage tank, indirect or twin coil. Maximum working pressure of the cylinder 6.0 bar, maximum working pressure of the coil or coils 12.0 bar. Maximum operating temperature 95°C.
Range of wall mounted, exposed, bar type thermostatic shower mixers (chromium plated brass) with a 2-way ceramic disc diverter controlling the flow to either shower outlet. Temperature is controlled independently via a thermostatic cartridge which incorporates a manual override button. The S06 model has dome type operating members and the S15-2 model has cube type operating members. The inlets incorporate a stainless-steel strainer and an approved check valve cartridge; however, the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum working pressure 10.0 bar. Maximum operating temperature 85°C.
Range of wall mounted, concealed, thermostatic mixing vales with brass bodies and chrome plated trim sets, incorporating one or two quarter turn ceramic disc headworks with various operating members (see models). Temperature is controlled independently via a thermostatic cartridge with various operating members (see model) which incorporates a manual override button. Both inlets incorporate an approved check valve cartridge, however, the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum working pressure 6.0 bar. Maximum operating temperature 85°C.
Range of wall mounted thermostatic blending valves (chromium plated brass) incorporating a quarter turn ceramic disc headwork (with various operating members). The temperature is controlled independently via a thermostatic cartridge incorporating a manual override button. The inlets incorporate approved check valve cartridge(s), however, the complete product has not been fully tested to demonstrate it provides backflow protection and stainless steel strainers. Maximum working pressure 5.0 bar. Maximum operating temperature is 85°C.
Range of water filters cartridges with plastic bodies and either carbon block or activated carbon filter media. Maximum working pressure 8.6 bar. Maximum operating temperature 38°C.
Wall mounted exposed thermostatic shower valve incorporating a brass body (various finishes), quarter turn ceramic disc headwork with single lever operating members and manual diverter to shower outlet. The temperature is controlled independently via a thermostatic cartridge with cross top type operating member. The inlets incorporate a single check valve cartridge (however the complete assembly has not been tested to demonstrate it provides adequate backflow protection). The product is supplied with an overhead shower, shower handset, riser rail and shower hose. Maximum working pressure 5.0 bar Maximum operating temperature 60°C.
Range of wall mounted thermostatic shower valves (chrome plated) brass bodies incorporating a single sequential thermostatic cartridge controlling both flow and temperature. Models 86005770 & 86005780 have single lever operating members. Model 86005760 is not supplied with an operating member. both inlets incorporate single check valve cartridges (suitable for backflow protection against fluid category 2). Maximum working pressure 5.0 bar. Maximum operating temperature 60°C
Range of wall mounted thermostatic shower valves incorporating brass bodies (chrome plated) and a quarter turn ceramic disc headwork controlling the flow with single lever, cross top or dome type operating members. The temperature controlled is independently via a thermostatic cartridge incorporating a manual override button with cross top, dome type or single lever operating members. Both inlets incorporate stainless steel strainers and approved single check valve cartridges however, the complete assemblies have not been fully tested to demonstrate that they provide adequate backflow protection). Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.
Wall mounted thermostatic bar shower valve, riser rail, shower handset, shower hose and overhead shower outlet. The valve incorporates a brass body (chrome plated) and ceramic disc headwork with dome type operating member which controls and diverts the flow between the two shower outlets. The temperature is controlled independently via a thermostatic cartridge with a dome type operating member incorporating a manual override button. The inlets incorporate stainless steel filters and a single check valve cartridge however the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.
Thermostatic cartridge with brass body, and EPDM ‘O’-rings. For insertion into specifically dimensioned bores. Maximum working pressure 5.0 bar. Maximum operating temperature 85°C
Wall mounted thermostatic blending valve (chrome plated brass) incorporating a quarter turn ceramic disc headwork with dome type operating members. The temperature is controlled independently via a thermostatic cartridge incorporating a manual override button. The inlets incorporate approved single check valve cartridge, however, the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum working pressure 5.0 bar. Maximum operating temperature is 60°C.
Range of wall mounted, concealed, thermostatic shower blending valves incorporating stainless steel bodies, a 2-way ceramic disc headwork and a single lever operating member controlling the flow. The temperature is controlled independently via a thermostatic cartridge with a single lever incorporating a manual override operating member. Both inlets incorporate an approved check valve cartridge, however, the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.
Range of wall mounted, exposed, thermostatic bar type shower mixing valves (chromium plated brass). The246PG model incorporates a 2-way ceramic disc diverter headwork with a dome type operating member controlling the flow between an overhead shower outlet and a shower handset. The 536PG model incorporates a quarter turn ceramic disc headwork with a dome type operating member controlling the flow to a shower handset. The temperature is controlled independently via a thermostatic cartridge with a dome type operating member which incorporates a manual override button. Both inlets incorporate a combined EPDM washer and stainless-steel strainer, as well as an approved single check valve cartridge, however, the complete product has not been fully tested to demonstrate it provides backflow protection. Both products are supplied with a shower hose and handset, the B36264 model also includes a shower riser to an overhead shower outlet. Maximum working pressure 8.0 bar. Maximum operating temperature 60°C.
Range of wafer and lugged type, concentric butterfly valves with epoxy coated cast iron bodies, austenitic steel discs and EPDM seats. Maximum working pressure 16.0 bar. Cold water use only.
Range of butterfly valves incorporating blue epoxy coated ductile iron bodies & wedges and EPDM sealing gasket. The closing mechanism is controlled by a hand wheel operating member. Maximum working pressure 16.0 bar. Maximum operating temperature 85˚C.
Range of lug type butterfly valves incorporating blue epoxy coated cast iron bodies, stainless steel discs, EPDM seats and lever type operating member. Maximum working pressure 16.0 bar (models 2108 12, 2108 13 and 2108 14). Maximum working pressure 10.0 bar (models 210816 and 2108 18). Maximum operating temperature 100°C.
Range of lug type butterfly valves incorporating blue epoxy coated cast iron bodies, stainless steel discs, EPDM seats and lever type operating member. Maximum working pressure 16.0 bar. Maximum operating temperature 100°C.
Range of shower bars with brass bodies (various finishes), incorporating a manual diverter with cube or dome type operating members, which diverts between an overhead shower and a shower hose and handset. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.
2-way ceramic disc diverter with a plastic body, NBR ‘O’-rings and silicone seals. For insertion into specifically dimensioned bores. Maximum working pressure 10.0 Bar. Maximum operating temperature 85°C.
Range of wall mounted, concealed flow control valves with brass bodies, incorporating either one or two quarter turn ceramic disc headworks with single lever operating members. Maximum working pressure 10.0 bar. Maximum operating temperature 65°C.
‘Europress’ range of in-line pressure reducing valves, with DZR brass bodies and EPDM ‘O’-rings and washer. The outlet pressure is adjustable between 1.0 - 5.5 bar. Operating parameters: 2430012 EUROPRESS model: Maximum inlet supply pressure 25.0 bar. Maximum operating temperature 80°C. 2430034 EUROPRESS & 2430100 EUROPRESS models: Maximum inlet supply pressure 16.0 bar. Maximum operating temperature 99°C.
Range of adjustable pressure reducing valves incorporating a plastic body and EPDM ‘O’-rings and stainless steel strainers. Outlet pressure 1.2 - 8.0 bar. Maximum inlet supply pressure 16.0 bar. Maximum operating temperature 85°C.
Range of pressure relief valves pre-set @ 6.0 bar, incorporating DZR brass bodies, EPDM seal cup and EPDM ‘O’-ring. Maximum operating temperature 99˚C
‘EV220A-W’ range of normally closed solenoid valves with brass bodies, EPDM diaphragms and ‘O’-rings. Maximum working pressure 10.0 bar. Maximum operating temperature 90°C.
Aquatsop leak detection system intended to shut the water supply in the event of a water leak. Consisting of two single normally closed servo controlled solenoid valves with a flow regulator and stainless steel filter at the inlet. A LDPE inner hose with corrugated plastic outer hose. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.
Range of angled isolation valves with brass bodies (brushed chrome plated), for use with copper tube manufactured to EN1057. The inlet incorporates an approved check valve cartridge however, the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.
Range of spherical valves with bronze bodies, DZR brass ball (sizes ½” to 1”) and bronze ball (sizes 1 ¼” to 2”) PTFE seats and various operating member types (see models). Maximum working pressure: 25.0 bar. Maximum operating temperature: 85⁰C.
Range of gate valves incorporating brass bodies and wedges with EPDM ‘O’-rings and a non-rising spindle with a hand wheel operating member. Maximum working pressure 16.0 bar. Maximum operating temperature 85°C.
Range of gate valves incorporating ductile iron epoxy coted bodies and with EPDM ‘O’-ring seals and discs. The valves are operated via a non-rising spindle with a hand wheel operating member Maximum working pressure 16.0 bar. Maximum operating temperature 85°C.
Range of gate valves with blue epoxy coated ductile iron bodies and EPDM coated ductile iron wedges. The valves are operated via a non-rising spindle with a hand wheel operating member. Maximum working pressure 16.0 bar. Maximum operating temperature 85°C.
Range of gate valves with blue epoxy coated ductile iron bodies and EPDM coated ductile iron wedges. The valves are operated via a non-rising spindle with a hand wheel operating member. Maximum working pressure 16.0 bar. Maximum operating temperature 85°C.
Range of gate valves with blue epoxy coated ductile iron bodies and EPDM coated ductile iron wedges. The valves are operated via a non-rising spindle with a hand wheel operating member. Maximum working pressure 16.0 bar. Maximum operating temperature 85°C.
Range of 115 gate valves with blue epoxy coated ductile iron bodies and EPDM coated ductile iron wedges. The valves are operated via a non-rising spindle with a hand wheel operating member. Maximum working pressure 16.0 bar. Maximum operating temperature 85°C.
Range of commercial dishwashers with flow controlled by a solenoid valve and discharged via a type AB air gap (verified by test - suitable for backflow protection against fluid category 5). Maximum working pressure 4.0 bar. Cold water use only.
Range of water conditioners incorporating a static PTFE and zinc anode in a brass or nickel plated bronze body. Between November 2021 and December 2023 the maximum working pressure is: ET/ETD models = 10.0bar, EF/EF-16 models = 16.0 bar, EF-40 models = 40.0 bar. From January 2024 the maximum working pressure is: ET/ETD/EF/EF-16 models = 16.0 bar & EF-40 models = 40.0 bar. Maximum operating temperature 60°C.
Range of electrolytic scale inhibitors incorporating copper bodies. For use with copper pipe complying with BS EN 1057. Maximum working pressure 10.0 bar. Maximum operating temperature 40°C.
Range of UV disinfection units with stainless steel and EPDM seals. The UV lamps are housed inside synthetic quartz tubes Maximum working pressure 6.9 bar. Cold water use only.
Hostaform®, injection moulded POM materials. For use with water up to 85°C: Hostaform® Special Grade: M25AE 10-2013 & M25AE 10-2013 ECO-B (black coloured). Hostaform® Glass Bead Filled Grade: C9021 GV3/30 NATURAL. Hostaform® M30RS Natural & M30RS ECO-B NATURAL. For use with water up to 65°C: Hostaform® Unfilled Grades: T1020 NATURAL. Hostaform® Glass Fibre Filled Grades: C9021 GV1/10 NATURAL, C9021 GV1/20 NATURAL, C9021 GV1/30 NATURAL, C9021 GV1/30 3134 NATURAL & C9021 GV1/30 3134 ECO-B NATURAL. Hostaform® Glass Bead Filled Grades: C9021 GV3/10 NATURAL & C9021 GV3/20 NATURAL. Hostaform® Special Grades: M25IE natural, M25IE ECO-B NATURAL & M30AE. Between April 2021 and 2nd August 2022, these grades were for use with water up to 65°C. Between 3rd August 2022 and 30th April 2026, these grades are for use with water up to 85°C: Hostaform® Unfilled Grades: M15HP NATURAL, M15HP ECO-B NATURAL, C2521 NATURAL, C2521 ECO-B NATURAL, C9021, C9021 ECO-B NATURAL, C 9021 ECO-C 872 NATURAL, C13021 NATURAL, C13021 ECO-B NATURAL, C 13021 ECO-C 872 NATURAL, C13031 NATURAL, C13031 ECO-B NATURAL, C 13031 ECO-C 872 NATURAL, C27021 NATURAL, C27021 ECO-B NATURAL & C 27021 ECO-C 872 NATURAL. Hostaform® Lubricated Grades: C9021 M (Natural colour is grey), C9021 M ECO-B NATURAL, C9021 FCT1 NATURAL, C9021 FCT1 ECO-B NATURAL, C9021 TF NATURAL, C9021 TF ECO-B NATURAL, C9021 K NATURAL, C9021 K ECO-B NATURAL, C13021RM NATURAL & C13021RM ECO-B NATURAL. Hostaform® Special Grade: MR130ACS NATURAL & MR130ACS ECO-B NATURAL. These grades were added January 2022. Between January 2022 and 2nd August 2022, these grades were for use with water up to 65°C. Between 3rd August 2022 and 30th April 2026, these grades are for use with water up to 85°C: Tarnoform® 200 CE natural, 300 CE natural, 400 CE natural, 411 CE natural & 500 CE natural. Between April 2021 and xx February 2023, these grades were for use with water up to 65°C. Between 16th February 2023 and 30th April 2026, these grades are for use with water up to 85°C: Hostaform® Unfilled Grades: C 52021 NATURAL & C 52021 ECO-B NATURAL. Tarnoform® 700 CE. Hostaform® Special Grades: C13031 XAS-G NATURAL, C13031 XAS-G ECO-B NATURAL, M25AE NATURAL, M25AE ECO-B NATURAL & HF M25AE ECO-C 872 NATURAL. For use with water up to 65°C: Grade added February 2023: Hostaform® M25AE 10/5358 DW. Grade added April 2025: Hostaform® MR130 ACS 10/5358 DW Black. For use with water up to 85°C: Grade added April 2025: Hostaform® M25AE 10/5358 DW black.
`POWLAC EY161`. Factory applied, blue coloured epoxy powder coating. Apply as per manufacturer's instructions `no. CKP-2015-0172`. Cure for 5 minutes@180°C. For use with water up to 85°C. If the cure conditions are varied from those specified on the approval then the material is not covered by the scope of the approval.
'ELASTOPOXY PRIMER HP and ELASTOSEAL W Coating'. Factory applied, grey coloured (once mixed), two-component primer (non-water contact primer) and two-component coating (water contact coating). Mix and apply 'ELASTOPOXY PRIMER HP as per Product Data Sheet ‘TSS/TD/280721/C’. Cure for 2 hours@25°C. Then mix and apply ‘ELASTOSEAL W Coating’ as per Product Data Sheet ‘TSS/TDS/260721-B’. Cure for 1 minute@25°C. For use with water up to 85°C.
'SYI-03'. Factory applied, grey coloured, Portland cement mortar. Mix cement, sand and water in a mass ratio of 1:1.5:0.6. Cure for 4 hours@23°C. For use with water up to 65°C. This material is only approved for the mixing and curing conditions that appear on the approval. If the mix and/or cure conditions are varied from those specified on the approval then the material is not covered by the scope of the approval.
'Nu Vista'. Factory applied, grey coloured Portland Slag Cement. Mix water, sand and cement in a mass ratio of 1:2:3. Cure for 1.5 hours@30°C, then 4 hours at 45°C and then 28 days (672 hours)@35°C. For use with water up to 60°C. This material is only approved for the mixing and curing conditions that appear on the approval. If the mixing and/or curing conditions are varied from those specified on the approval then the material is not covered by the scope of the approval.
'TML Dalmia Infra Pro'. Factory applied, grey coloured Portland Slag Cement. Mix water, sand and cement in a mass ratio of 1:2:3. Cure for 1.5 hours@30°C, then 4 hours@45°C and then 28 days (672 hours) @35°C. For use with water up to 60°C. This material is only approved for the mixing and curing conditions that appear on the approval. If the mixing and/or curing conditions are varied from those specified on the approval then the material is not covered by the scope of the approval.
'SC2 Coating'. Factory applied, clear, PTFE based coating. Apply and cure as per manufacturer's instructions 'LDAP-002 issue 1' dated 09-08-2016. For use with water up to 85°C.
'Protecfull SFP 108'. Factory applied, two-component, cream coloured polyurethane coating. Mix part A & part B in a 75:25 volume ratio and apply as per manufacturer's instructions reference '016. Ed.01.21' dated August 24, 2021. Cure for 7 days@23°C. For use with water up to 23°C. This material is only approved for the mixing and curing conditions that appear on the approval. If the mixing and/or curing conditions are varied from those specified on the approval then the material is not covered by the scope of the approval.
'Hempaline Defend 630 Cure 72'. Factory applied, white coloured, two-component epoxy coating. Mix base and curing agent in a 3:1 volume ratio and apply as per manufacturer's product data sheets dated June 2021, Cure for 6 days@20°C. For use with water up to 60°C. This material is only approved for the curing conditions that appear on the approval. If the cure conditions are varied from those specified on the approval then the material is not covered by the scope of the approval.
'EP-I-103'. Factory applied, blue coloured fusion bonded epoxy coating. Apply and cure as per manufacturer's instructions issue 'EPOXY86315', dated 'Nov. 15th, 2020'. For use with water up to 65°C.
'Rilsan (MagnaCoat 5501 F)'. Factory applied, white coloured (opaque), polyamide powder coating. Apply as per manufacturer's instructions dated 02/01/2018. Cure for 10 minutes@230°C. For use with water up to 65°C. This material is only approved for the curing conditions that appear on the approval. If the cure conditions are varied from those specified on the approval then the material is not covered by the scope of the approval.
'SC1 Coating'. Factory applied, clear, PTFE based coating. Apply and cure as per manufacturer's instructions 'LDAP-001 issue 1' dated 09-08-2016. For use with water up to 85°C.
"Bond-It Tanking Slurry". Site applied, grey coloured, two part (powder & water) cementitious waterproof coating. Mix and apply as per manufacturer`s instructions 'Version 9' dated 06/08/20. Cure for 12 days at 7°C. For use with water up to 23°C. This material is only approved for the curing conditions that appear on the approval. If the cure conditions are varied from those specified on the approval then the material is not covered by the scope of the approval.
'568H+L101'. Natural (appears off-white in colour), injection moulded GRP material. For use with water up to 70°C.
`8601-A`. Extruded, dual layered hose consisting of a clear PE liner and black coloured EPDM outer layer. Shore hardness 85. For use with water up to 85°C.
'Plustek PA303G6BK16'. Black coloured, injection moulded PA material. For use with water up to 85°C.
'LATAMID 66 H2 G/30 BLACK F:3352'. Black coloured, injection moulded PA66 material. For use with water up to 65°C.
'Xytrex 116'. Dark grey coloured, hot compression moulded PEEK washer. For use with water up to 85°C.
'AO Roto Water Tank Panel'. White coloured, LLDPE tank panel manufactured by rotational moulding. For use with water up to 60°C.
'Hostalen CRP100 Black & Hostalen CRP100 RESIST CR Black'. Black coloured HDPE materials, manufactured in Saudi Arabia and Germany, for injection moulding and extrusion purposes. For use with water up to 60°C.
'Total 3581 Blue Polyethylene & Total 3581 Black Polyethylene'. Blue or black coloured, polyethylene material manufactured by rotational moulding. For use with water up to 65°C.
'Total 4041 Blue Polyethylene & Total 4041 Black Polyethylene'. Blue or black coloured, polyethylene material manufactured by rotational moulding. For use with water up to 65°C.
'Helisystem CT fitting'. Green coloured, injection moulded PP-RCT fitting. Between July 2021 and September 2022, the fitting was for use with water up to 23°C. Between October 2022 and July 2026, the fitting is for use with water up to 75°C.
'RTP 499 X 129130 A Natural & RTP 499 X 136502 Natural'. Natural (appear grey in colour), injection moulded polystyrene materials. For use with water up to 50°C.
'Chang QI/CFPC'. White coloured PTFE tape manufactured by press strip roller. For use with water up to 60°C.
'Art. 0985077205 Anti-leak Tape'. Site applied, off-white coloured, fibre glass impregnated, polyurethane repair tape. Apply as per manufacturer's technical data sheet version '001' dated 26.07.2021. Cure for 30 minutes@23°C. For use with water up to 23°C. This material is only approved for the curing conditions that appear on the approval. If the cure conditions are varied from those specified on the approval then the material is not covered by the scope of the approval.
'Chemfix 600'. Red coloured chemical anchor resin supplied in a pre-weighed dual cartridge. Apply as per manufacturer's instructions dated '11/11/2020'. Cure for 48 hours@7°C. For use with water up to 23°C. For use only as a resin anchor having been tested at a reduced surface area to volume ratio of 1,000mm² per 1 litre of water. This material is only approved for the curing conditions that appear on the approval. If the cure conditions are varied from those specified on the approval then the material is not covered by the scope of the approval.
`1025 Titan Bladder`. Black coloured, calendared butyl rubber sheet material. Shore hardness 60. Tested in-radius size 0.5mm. For use with water up to 23°C.
'EP7008S 'O' rings and gaskets'. Black coloured, compression moulded EPDM 'O' rings and gaskets. Shore hardness 70. Tested in-radius size between 0.25mm & 3.5mm. For use with water up to 60°C.
'EP1/1/6 BLK' O-rings. Black coloured, injection moulded EPDM 'O' rings. Shore hardness 80. Tested in-radius size 1.75mm. For use with water up to 85°C.
'EP906'. Black coloured, extruded EPDM washer. Shore hardness 90. Tested in-radius size 1.4mm. For use with water up to 85°C.
'ERIKS 55985 Gaskets & ‘O’ rings'. Black coloured, compression moulded EPDM gaskets & ‘O’ rings'. Shore hardness 70A. The gaskets have a tested in-radius size of 1.0mm. The ‘O’ rings have a tested in-radius size of 1.76mm. For use with water up to 85°C.
'LOPI60 & LOPI70'. Black coloured, injection moulded, EPDM 'O' rings. Shore hardness 60 & 70 respectively. Tested in-radius size 0.75mm. For use with water up to 85°C.
'LOPI60 & LOPI70'. Black coloured, injection moulded, EPDM 'O' rings. Shore hardness 60 & 70 respectively. Tested in-radius size 0.75mm. For use with water up to 85°C.
'CEW50, CEW55, CEW60, CEW65, CEW70, CEW75, CEW80, CEW85 & CEW88'. Black coloured, transfer moulded EPDM rubber materials. Shore hardness between 50 & 88. Tested in-radius size 1.15mm. For use with water up to 60°C.
'CVE45, CVE48, CVE50, CVE52, CVE55, CVE60, CVE61, CVE65, CVE69, CVE70, CVE75, CVE78 & CVE80'. Black coloured, extruded, EPDM materials. Shore hardness between 45 & 80. Tested in-radius size 1.5mm. For use with water up to 60°C.
'51M5567'. Black coloured, injection moulded EPDM material. Shore hardness 55. Tested in-radius size 0.5mm. For use with water up to 23°C.
‘AquaFlex® T 5818’. Black coloured, compression moulded EPDM material. Shore hardness 70. Tested in-radius size 1.1mm. For use with water up to 65°C.
'AquaFlex T 5817'. Black coloured, compression moulded EPDM material. Shore hardness 70. Tested in-radius size 1.1mm. For use with water up to 65°C.
'RVK EPDM EP 210107'. Black coloured, compression moulded EPDM material. Shore hardness 70. Tested in-radius size 1.0mm. For use with water up to 65°C.
'TWK4563'. Black coloured, injection moulded EPDM material. Shore hardness 55. Tested in-radius size 0.5mm. For use with water up to 23°C.
'E0265'. Black coloured, compression moulded EPDM material. Shore hardness 80. Tested in-radius size 1.0mm. Between September 2021 and 3rd August 2022, the material was for use with water up to 23°C. Between 4th August 2022 and September 2026, the material is for use with water up to 50°C
'Uneplas Gel Solvent Cement'. Clear, transparent (un-pigmented) solvent cement, (intended to join PVC pipe and fittings). Apply as per manufacturer's instructions review date '2019-09-11'. Cure for 20 days at 7°C. For use with water up to 65°C. This material is only approved for the curing conditions that appear on the approval. If the cure conditions are varied from those specified on the approval then the material is not covered by the scope of the approval.
'Hytrel® HTR6108'. Translucent cream coloured, injection moulded thermoplastic elastomeric material. Shore hardness 61. For use with water up to 85°C.
WC flushing cistern incorporating a side entry compact type float operated inlet valve providing a Type AG air gap with a dual flush drop valve for full flush volumes of up to 6 litres and a reduced flush of up to 4 litres. The cistern is operated by a manual push button and incorporates a servicing valve on the inlet supply. Maximum working pressure 10.0 bar. Cold water use only.
WC flushing cistern incorporating a side entry compact type float operated inlet valve providing a Type AG air gap with a dual flush drop valve for full flush volumes of up to 6 litres and a reduced flush of up to 4 litres. The cistern is operated by a manual push button and incorporates a servicing valve on the inlet supply. Maximum working pressure 10.0 bar. Cold water use only.
WC flushing cistern incorporating a side entry compact type float operated inlet valve providing a Type AG air gap with a dual flush drop valve for full flush volumes of up to 6 litres and a reduced flush of up to 4 litres. The cistern is operated by a manual push button and incorporates a servicing valve on the inlet supply. Maximum working pressure 10.0 bar. Cold water use only.
Type ‘AB’ air gap assembly (verified by test - suitable for backflow protection against Fluid Category 5) with flow controlled via a solenoid valve. Supplied with EPDM inlet hoses that incorporate a single check valve cartridge, however the check valve has not been fully tested to demonstrate it provides backflow protection. Max working pressure 6.0 bar. Maximum operating temperature 60ºC.
Range of check valve cartridges with plastic bodies to be housed in specifically dimensioned bodies. The product incorporates a plastic flow regulator. Maximum working pressure 16.0 bar & maximum operating temperature 65°C.
Type TK, spring loaded resilient trim, in-line check valve cartridge with plastic guides and stem and EPDM seals within a plastic housing. For insertion into pipes or fittings with specifically dimensioned bores. Maximum working pressure 16.0 bar. Maximum operating temperature 85°C.
Spring loaded resilient trim, in-line check valve cartridge with plastic guides and stem and EPDM seals within a plastic housing. For insertion into pipes or fittings with specifically dimensioned bores. Maximum working pressure 16.0 bar & maximum operating temperature 65°C.
Non-rising spindle headwork incorporating a brass body and NBR ‘O’-rings to be inserted into specifically dimensioned bodies. Maximum working pressure 16.0 Bar Maximum operating temperature 85°C.
Range of ceramic disc headworks with brass bodies to be inserted into specifically dimensioned bodies. Maximum working pressure 16.0 bar. Maximum operating temperature 85°C
Range of thermostatic cartridges with plastic bodies, stainless steel strainers and EPDM ‘O’-rings. For insertion into specifically dimensioned bodies. Maximum operating temperature 65°C.
Single hole, single outlet (swivel) combination tap assembly (chromium plated brass), incorporating ceramic cartridge headworks with single lever operating members and pull-down spray handset. The spout outlet incorporates a plastic aerator. The product is supplied with a metal backnut. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.
Single hole, single outlet (fixed) combination tap assembly (chrome plated brass). Incorporating a ceramic cartridge headwork and single lever operating member. The spout outlet incorporates a plastic aerator. Maximum working pressure 5 bar. Maximum operating temperature 60°C.
Range of single hole, single outlet (fixed) combination tap assemblies with brass bodies (various finishes - see model), incorporating ceramic a cartridge headwork with a single lever operating member. The spout outlets incorporate a plastic aerator. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.
Range of single hole, single outlet (fixed) combination tap assemblies (brass bodies with various finishes - see model), incorporating a ceramic cartridge headwork with a single lever operating member. The spout outlet incorporates a plastic aerator. Some models are supplied with a lever operated pop-up waste or click type waste. Maximum working pressure 10.0 Bar. Maximum operating temperature 60°C.
Range of single hole, single outlet (fixed) combination tap assemblies (brass bodies with various finishes - see model), incorporating a ceramic cartridge headwork with a single lever operating member. The spout outlet incorporates a plastic aerator. Some models are supplied with a pop-up waste (see model). Maximum working pressure 10.0 bar. Maximum operating temperature 60°C
Range of single hole, single outlet (fixed) combination tap assemblies (brass bodies with various finishes), incorporating a ceramic cartridge headworks with single lever operating members. The spout outlet incorporates a plastic aerator. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.
Range of single hole, single outlet (fixed) combination tap assemblies (chromium plated brass) incorporating a ceramic cartridge headwork with a single lever operating member. The spout outlet incorporates a plastic aerator. Products are supplied with a pop-up waste. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.
Range of single hole, single outlet (fixed) combination tap assemblies with brass bodies (various finishes), incorporating a ceramic cartridge headwork with a single lever operating member. The spout outlet incorporates a plastic aerator. Some products are supplied with a pop-up waste or a click type waste (see model). Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.
Ragfe of single hole, single outlet (fixed) combination tap assembly with stainless steel bodies (various finishes), incorporating a ceramic cartridge headwork with a single lever operating member. The spout outlet incorporates a plastic aerator with an integral flow regulator. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.
Single hole, single outlet fixed combination tap assembly (chromium plated brass), incorporating a ceramic cartridge headwork with a single lever operating member. The spout outlet incorporates a plastic aerator. Product supplied with an approved click-type pop up waste. Maximum operating pressure 10.0 bar. Maximum operating temperature 60°C.
Range of single hole, single outlet (fixed) combination tap assemblies (various finishes) incorporating a ceramic cartridge headwork with a single lever operating member. The spout outlet incorporates a plastic aerator. The 36 100 xxx model is supplied with a lever operated pop-up waste. Maximum working pressure 10.0 Bar. Maximum operating temperature 60°C.
Floor mounted, single hole, single outlet (fixed) combination tap assembly with brass body (various finishes - see model), incorporating a ceramic cartridge headwork with a single lever operating member and a self-cancelling diverter to shower outlet (activated by pulling the end of the spout surround). The shower outlet incorporates an approved check valve cartridge however, the complete product has not been fully tested to demonstrate it provides backflow protection. The spout outlet incorporates a plastic aerator. The product is also supplied with shower hose and shower handset. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.
Floor-standing single hole, single outlet (fixed) combination tap assemblies with brass bodies (various finishes - see model), incorporating a ceramic cartridge headwork with a single lever operating member and a self-cancelling diverter to shower outlet. The spout outlet incorporates a plastic flow straightener. Maximum working pressure 6.9 bar. Maximum operating temperature 60°C.
Range of single hole, single outlet (swivel) combination tap assemblies (stainless steel – various finishes). The flow of hot and cold water is controlled by a ceramic cartridge headwork with a single lever operating member. The flow of near-boiling water is controlled by a ceramic disc headwork, with spring loaded single lever operating member. Maximum working pressure 5.0 bar. Maximum operating temperature 96°C.
Range of single-hole, single outlet (swivel) combination tap assemblies (brass bodies with various finishes - see model), incorporating either quarter turn ceramic disc or ceramic cartridge headworks with either a wheel type or single lever operating member (see model). The spout outlet incorporates a plastic aerator. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.
Range of single hole, single outlet (swivel), combination tap assemblies (chromium plated brass). Incorporate a quarter turn ceramic disc headworks with single lever operating members (Models Cresta, Sion & Henley) or ceramic cartridge headworks with single lever operating members (model Reno). The inlets incoprorate approved check valve cartridges, however the complete product has not been fully tested to demonstrate it provides backflow protection. The spout outlets incorporate a plastic aerator. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.
Range of single hole, single outlet (swivel) combination tap assemblies (chromium plated brass). Incorporating ceramic disc headworks with single lever operating members. The spout outlets incorporate a plastic aerator. The cold inlet hose incorporates an approved check valve cartridge, however, the complete product has not been fully tested to demonstrate it provides backflow protection Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.
Range of single hole, single outlet (swivel) combination tap assemblies (chromium plated brass), incorporating a ceramic disc headworks with a single lever operating members. The spout outlet incorporates a plastic flow straightener or aerator. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.
Single hole, single outlet (swivel) combination tap assembly (stainless steel body - various finishes, see model), incorporating a ceramic cartridge headwork with a single lever operating member. The spout outlet incorporates a plastic aerator with an integral flow regulator. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.
Single hole, single outlet (swivel), combination tap assembly (chromium plated brass), incorporating a ceramic cartridge headwork with a single lever operating member. The spout incorporates a push to open, push to close ‘detent’ headwork and the spout outlet incorporates a plastic aerator. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.
Two hole, single outlet fixed combination tap assembly (chrome plated brass) incorporating quarter turn ceramic disc headworks with single lever operating members. The spout outlet incorporate a plastic flow straightener and the product is supplied with metal back nuts. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.
Wall mounted, two-hole, single outlet (fixed) combination tap assemblies, comprising of a concealed brass body, and a separate trim set (brass body - various finishes), incorporating a ceramic cartridge headwork with a joystick type operating member and a spout outlet. The spout outlet incorporates a plastic aerator. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.
Two-hole, single outlet (fixed) combination tap assembly with brass body (various finishes) incorporating quarter turn ceramic disc headworks with various operating members. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.
Two-hole, single outlet (fixed) combination tap assembly with brass body (various finishes) incorporating half turn ceramic disc headworks with various operating members. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.
Range of two hole, single outlet (fixed) combination tap assemblies with brass bodies (various finishes) incorporating quarter turn ceramic disc headworks with single lever operating members. The spout outlets incorporate an plastic aerator. The fitting is supplied with metal backnuts. Maximum working pressure 10.0 bar. Maximum operating temperature 60ºC.
Wall mounted two-hole, single outlet (fixed) combination tap assembly with a brass body (chrome trim set) incorporating a ceramic cartridge headwork and single lever operating members. The spout outlets incorporate a plastic aerator. Maximum working pressure 8.0 bar. Maximum operating temperature 60°C.
Range of deck mounted two hole, single outlet (fixed) combination tap assemblies (chromium plated brass) incorporating quarter turn ceramic disc headworks with single lever operating members. The spout outlets are a waterfall type incorporating a stainless steel strainer. The products are supplied with plastic or brass backnuts. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.
Range of wall mounted, two hole, single outlet (fixed) combination tap assemblies (chromium plated brass) incorporating a ceramic cartridge headworks with a single lever operating member. The spout outlets are a waterfall type incorporating a stainless-steel strainer. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.
Range of deck mounted two hole, single outlet (fixed) combination tap assemblies (chromium plated brass), incorporating quarter turn ceramic disc headworks or a ceramic cartridge headwork (SH-T8025A model only) with various operating members (see models). The spout outlet either incorporates a plastic flow straightener or an open outlet (see models). The products are supplied with metal backnuts. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.
Range of deck mounted, two hole, single outlet (fixed) combination tap assemblies (chromium plated brass), incorporating quarter turn ceramic disc headworks with various operating members (see models). The spout outlet either incorporates a plastic flow straightener or an open outlet (see models). The products are supplied with metal backnuts. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.
Range of wall mounted, two-hole, single outlet (fixed) combination tap assemblies (chromium plated brass), incorporating a ceramic cartridge headwork with a single lever operating member. The spout outlet incorporates a plastic flow straightener. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.
Range of two hole, single outlet (fixed) combination tap assemblies (chromium plated brass), incorporating quarter turn ceramic disc headworks or a ceramic cartridge headwork (SH-T8025N model only) with various operating members (see models). The spout outlet either incorporates a plastic flow straightener, plastic aerator or an open outlet (see models). The products are supplied with metal backnuts. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.
Range of two hole, single outlet (fixed) combination tap assemblies with brass bodies (various finishes) incorporating ceramic cartridge headworks with single lever operating members Spout outlets incorporate a plastic aerator. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.
Range of two hole, single outlet, (fixed) combination tap assemblies (chromium plated brass), Models 49723, 26684 & 18193 incorporate a non rising spindle headwork with dome type operating members. The spout outlets incorporate a plastic flow straightener and the products are supplied with metal backnuts. . Maximum working pressure 10.0 bar. Maximum operating temperature 85°C.
Range of wall mounted, two-hole, single outlet (fixed) combination tap assemblies (chromium plated brass), incorporating a ceramic cartridge headwork with a single lever operating member. The spout incorporates a plastic aerator. Maximum working pressure 10.0 bar. Maximum working temperature 60°C.
Two hole, single outlet (fixed) combination tap assembly (chromium plated brass), incorporating quarter turn ceramic disc headworks, single lever operating members and a manual diverter to shower outlet. The spout outlet incorporates a plastic flow straightner. The product is supplied with a shower hose, handset and metal backnuts. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.
Two hole, single outlet, fixed combination tap assembly (chromium plated brass) incorporating quarter turn ceramic disc headworks with single lever operating members and a manual diverter to shower outlet. The spout outlet incorporates a plastic flow straightener. The product is supplied with a shower hose, shower handset and metal backnuts, Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.
Wall mounted, two-hole, single outlet (fixed) combination tap assembly (brass body with various finishes - see model), incorporating a 2 way ceramic disc diverter headwork controlling the flow between the spout or shower outlet with a single lever operating member. Temperature is controlled independently via a thermostatic mixing valve incorporating a single lever operating member with a manual override button. Each inlet incorporates an approved single check valve cartridge; however, the complete product has not been fully tested to demonstrate it provides backflow protection. The spout outlet incorporates a plastic aerator. Maximum working pressure 10.0 Bar. Maximum working temperature 60°C.
Range of two-hole, single outlet (fixed) combination tap assemblies (chromium plated brass), incorporating quarter turn ceramic disc or ceramic cartridge headworks with either single lever or cross top (SH-T8181 model only) operating members and manual diverter to shower outlet. The spout outlet incorporates a plastic flow straightener. The products are supplied with metal back nuts. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.
Range of two-hole, single outlet (fixed) combination tap assemblies (chromium plated brass), incorporating quarter turn ceramic disc or ceramic cartridge headworks various operating members (see models) and a manual diverter to shower outlet. The spout outlet either incorporates a plastic flow straightener, plastic aerator or an open outlet (see models). The products are supplied with metal back nuts. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.
Range of two-hole, single outlet (fixed) combination tap assemblies (chromium plated brass), incorporating quarter turn ceramic disc headworks with either single lever or dome type (SH-T8062 model only) operating members and manual diverter to shower outlet. The spout outlet incorporates a plastic flow straightener. The products are supplied with metal back nuts. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.
Range of two-hole, single outlet (fixed) combination tap assemblies (chromium plated brass), incorporating quarter turn ceramic disc headworks with single lever operating members and a manual diverter to shower outlet. The spout outlets are a waterfall type incorporating a stainless steel strainer. The products are supplied with metal back nuts. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.
A range two-hole wall or floor mounted combination tap assemblies incorporating brass bodies (variety of finishes), and quarter turn ceramic disc headwork with either cross top or single lever operating members. The products incorporate a manual diverter to a shower outlet with a single lever operating member and the spout outlets incorporate plastic aerator. The products are supplied with a shower handset & shower hose. Maximum working pressure 5 bar. Maximum operating temperature 60°C.
Range of two-hole, single outlet (fixed) combination tap assemblies (chromium plated brass) incorporating quarter turn ceramic disc headworks with single lever or cross top operating members and a manual diverter to the shower outlet. The spout outlet incorporates a plastic flow straightener. The product is supplied with metal or plastic backnuts. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.
Range of two-hole, single outlet (fixed) combination tap assemblies (chromium plated brass) incorporating quarter turn ceramic disc headworks with single lever or cross top operating members and a manual diverter to the shower outlet. The product is supplied with metal or plastic backnuts. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.
Range of two-hole, single outlet (fixed) combination tap assemblies (chromium plated brass) incorporating quarter turn ceramic disc headworks with single lever or cross top operating members and a manual diverter to the shower outlet. The product is supplied with metal or plastic backnuts. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.
Two hole, single outlet, fixed combination tap assembly (chromium plated brass) incorporating quarter turn ceramic disc headworks with single lever operating members and a manual diverter to shower outlet. The spout outlet incorporates a plastic flow straightener. The product is supplied with a shower hose, shower handset and metal backnuts, Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.
Two hole, single outlet (fixed) combination tap assembly (chromium plated brass), incorporating quarter turn ceramic disc headworks with single lever operating members and a self-cancelling diverter to shower outlet. The spout outlet incorporates a waterfall outlet. The products are supplied with a shower hose and handset, and metal backnuts. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.
Two-hole, single outlet (fixed) combination tap assemblies (chromium plated brass), incorporating quarter turn ceramic disc headworks with single lever operating members and a self-cancelling diverter to shower outlet. The spout outlet incorporates a plastic flow straightener. The products are supplied with metal back nuts. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.
Two-hole, single outlet (fixed) combination tap assemblies (chromium plated brass), incorporating quarter turn ceramic disc headworks with single lever operating members and a self-cancelling diverter to shower outlet. The spout outlet incorporates a plastic flow straightener. The products are supplied with metal back nuts. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.
Range of two-hole, single outlet (fixed) combination tap assemblies (chromium plated brass), incorporating quarter turn ceramic disc headworks with single lever operating members and a self-cancelling diverter to shower outlet. The spout outlets incorporate either a plastic flow straightener or plastic aerator (SH-T9071 model only). The products are supplied with metal back nuts. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.
Two hole, single outlet (fixed) combination tap assembly with brass body (chrome plated), incorporating quarter turn ceramic disc headworks, single lever operating member and self cancelling diverter to shower outlet. The temperature is controlled independently via a thermostatic cartridge with single lever operating member. The shower outlet incorporates an approved check valve cartridge, however, the complete product has not been fully tested to demonstrate it provides backflow. The spout outlet incorporates a plastic aerator. Maximum working pressure 10.0 bar. Maximum operating temperature 65°C.
Range of two hole, single outlet (fixed) combination tap assemblies with brass bodies (various finishes - see model), incorporating quarter turn ceramic disc headworks with single lever operating members and a locakble self-cancelling diverter to shower outlet. The spout outlets incorporate a plastic aerator. The product is supplied with a shower hose and handset and metal backnuts Maximum working pressure 5.0 bar. Maximum working temperature 60°C.
Range of two-hole, single outlet (fixed) combination tap assemblies (chromium plated brass), incorporating quarter turn ceramic disc headworks with single lever operating members and a lockable diverter to shower outlet. The spout outlet incorporates a plastic flow straightener. The product is supplied with a shower hose, shower handset and metal backnuts Maximum working pressure 5.0 bar. Maximum operating temperature 60°C. .
Range of two hole, single outlet (fixed) combination tap assemblies (chromium plated brass), incorporating quarter turn ceramic disc headworks with single lever operating members and a lockable self-cancelling diverter to shower outlet. The spout outlet incorporates a plastic aerator. The products are supplied with a shower hose and handset, and metal backnuts. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.
Range of wall mounted, three-hole, single outlet (fixed) combination tap assemblies (various finishes - see model), incorporating quarter turn ceramic disc headworks and either single lever or dome type operating members (see model). The spout inlet incorporates an approved check valve cartridge, however, the complete product has not been fully tested to demonstrate it provides backflow protection. The spout outlet incorporates a plastic aerator. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.
Three hole, single outlet (fixed) combination tap assemblies with brass bodies (various finishes) incorporating quarter turn ceramic disc headworks with single lever operating members. Spout outlets incorporate a plastic aerator. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.
Range of three hole, single outlet (fixed) combination tap assemblies (brass bodies with various finishes). Incorporating quarter turn ceramic disc and various operating members. The spout outlet incorporates a plastic aerator (except Broadway and Niagara spout options). The product is supplied with nylon braided EPDM lined flexible hose assemblies incorporating ½” captive nut end connections on both ends or at one end and M10 at the other. The hoses are intended to connect between the side body headworks and the spout junction. The spout junction of the Malmaison and Niagara spout options incorporates a plastic flow regulator. The product is also supplied with either a click type or pop-up waste (see model), and a ½” BSP (F) nut and NBR washer to adapt the side valve inlet connections. Maximum working pressure 3.5 bar. Maximum operating temperature 60°C.
Range of three hole, single outlet (fixed) combination tap assemblies (brass bodies with various finishes). Incorporating quarter turn ceramic disc and various operating members. The spout outlet incorporates a plastic aerator. The product is supplied with nylon braided EPDM lined flexible hose assemblies incorporating ½” captive nut end connections on both ends or at one end and M10 at the other. The hoses are intended to connect between the side body headworks and the spout junction. The product is also supplied with a pop-up waste, and a ½” BSP (F) nut and NBR washer to adapt the side valve inlet connections. Maximum working pressure 3.5 bar. Maximum operating temperature 60°C.
Four hole, single outlet (fixed) combination tap assemblies with brass bodies (various finishes), incorporating quarter turn ceramic disc head work with single lever operating members (model WAI4BSMXX) and self cancelling diverter to shower outlet. The fitting is supplied with Stainless steel braided PEX lined flexible connecting hoses. The spout outlets incorporate a plastic aerator. Product is supplied with a shower hose and handset. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.
Wall mounted, spout outlet (brass body with various finishes - see model) incorporating a plastic aerator. The inlet incorporates an approved single check valve cartridge, however, the complete assembly has not been tested to demonstrate that it provides back flow protection. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.
Range of spout outlets incorporating stainless steel bodies (various finishes) and a plastic aerator. Maximum operating temperature 60°C.
Range of wall mounted spout outlets incorporating brass bodies (various finishes) & plastic aerators. Maximum operating temperature 60°C.
Spout outlet with a brass body (chrome plated). The spout outlet incorporates a combined plastic flow regulator and aerator. Maximum operating temperature 60°C.
Range of wall mounted spout outlets with brass bodies (chrome plated). Product is supplied with various operating members and pop up click waste. Maximum working pressure 5.5 bar. Maximum operating temperature 60°C.
Range of filling loop assemblies consisting of an in-line isolation valve, in-line double check valve assembly which also incorporates an isolation valve (suitable for back flow protection against fluid category 3) and stainless steel braided EPDM lined hose. The isolation valves are operated via a single lever. Maximum working pressure 10.0 bar. Maximum operating temperature 85°C.
‘Profine’ plastic bodied filter head incorporating EPDM ‘O’-rings for use with filter cartridges (not supplied).For use with LLDPE tube (manufactured to DIN 8072). All models can be specified with or without an integral bracket. Maximum working pressure 6.0 bar. Cold water use only.
Range of inline water filter cartridges with polypropylene housing with a carbon block filter. Maximum working pressure 8.5 Bar Cold water use only.
Range of brass, chrome plated brass or DZR brass compression fittings for use with copper pipe only. Maximum working pressure 16.0 bar. Maximum operating temperature 85°C.
Range of M type press fittings with TP2 copper bodies and EPDM ‘O’-rings, for use with TP2 copper pipe to EN1057. Above ground use only. Maximum working pressure 16.0 bar. Maximum operating temperature 85°C.
Copper brazed micro plate heat exchanger with copper and stainless-steel (316/1.4401) plates. Maximum working pressure 25.0 Bar. Maximum operating temperature 100°C
Range of ice making machines. The inlet supply is controlled by a solenoid valve. Inlet hose supplied. Maximum working pressure 5.0 bar. Cold water use only.
Range of water meter assemblies which incorporating DZR brass bodies, spherical valve and pressure reducing valve (1.5 to 6.0 bar range). The products incorporate two approved, in-line single check valve cartridges, (verified by test, suitable for backflow protection against Fluid Category 3). Fitting is also supplied with a pressure guage. Maximum working pressure 10.0 bar. Cold water use only.
Range of meter boxes incorporating a plastic manifold arrangement consisting of a stop valve with non-rising spindle , check valve (however the complete assembly has not been tested to demonstrate it provides adequate backflow) and concentric meter port. Some models incorporate a drain off or blacking plug. Connections can be compression or push fit (see model). For use with PE8-0 pipe to BS EN 12201 and copper to EN 1057. Maximum working pressure 16.0 bar. Cold water use only.
Bath spout incorporating a brass body (various finishes), EPDM ‘O’-rings and a plastic flow straightener. Maximum operating temperature 60°C
Range of pushfit hose connectors with either plastic (white or black) or chrome plated brass bodies and EPDM ‘O’-rings. SHCV prefix models incorporate screwdriver operated servicing valves. All pushfit connections are for use with PEX pipe (manufactured to BS7291-3) and copper pipe (manufactured to EN1057). Barbed end connections are not approved for use with any hose. Chrome plated brass body models are also for use with PB pipe (manufactured to BS7291-2). Maximum working pressure 10.0 bar (servicing valve models only). Barbed end connections are open outlet use only. Cold water use only.
Range of water hammer arrestor’s incorporating brass bodies (various finishes). The 525152 model is supplied with a reinforced captive nut. Maximum working pressure 10.0 bar. Maximum operating temperature 65°C. For products manufactured from June 2023 Maximum operating temperature 85°C
Range of flexible joints incorporating an EPDM (inner & outer) joint with a steel reinforcing ring and two carbon steel flanges. Maximum operating pressure 16.0 bar. Maximum operating temperature 65°C.
Chrome plated brass quick connector with EPDM washer. Maximum operating temperature 60°C.
Range of bidet spray kits comprising of a hand set with self-closing trigger, wall bracket, flexible hose assembly, thermostatic blending valve and isolation valve. Maximum working pressure 5 bar. Maximum working temperature 60°C
“Silent” range of booster pumps with plastic bodies and impellers and NBR ‘O’-rings. The SM900165A & SM600165A models incorporate a non-return valve on the outlet. Maximum working pressure 3.2 bar. Maximum operating temperature 35°C.
‘Para Z’ range of circulating pumps with either stainless steel, bronze or plastic bodies. Maximum working pressure 10.0 bar. Maximum operating temperature 85°C.
‘e-SH’ range of centrifugal booster pumps with a blue polymer coated stainless steel body, stainless steel impeller and EPDM ‘O’-rings. Maximum working pressure 12.0 bar. Cold water use only.
Range of overhead shower outlets incorporating a stainless steel body (various finishes), strainer and flow regulator on the inlets. Maximum operating temperature 60°C.
Range of shower heads with plastic bodies and a brass inlet connection. The inlet of the shower head incorporates an approved check valve cartridge, however, the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum operating temperature 70°C.
Shower handset with a plastic body (various finishes - see model). Maximum operating temperature 60°C.
Shower handset with a plastic body in a variety of finishes (see model). The inlet incorporates a combined EPDM washer and stainless-steel strainer, and a plastic flow regulator. Maximum operating temperature 60°C.
Range of wall mounted and overhead shower outlets, incorporating stainless steel strainers and flow regulators at the inlets. Maximum operating temperature 60°C
Shower outlets incorporating chrome plated ABS bodies. Maximum operating temperature 65°C.
Range of overhead showers and shower handsets with plastic body (various finishes). Overhead shower inlets incorporate a stainless steel strainer Maximum operating temperature 60°C.
Range of shower handsets incorporating plastic bodies (various finishes), plastic flow regulators and stainless steel strainers. Maximum operating temperature 60°C.
Range of shower kits, shower outlets and shower hoses. The shower handsets and overhead shower inlets incorporate a plastic flow regulator. Maximum operating temperature 45°C.
Shower handset with a plastic body in a variety of finishes (see model). The inlet incorporates a combined EPDM washer and stainless-steel strainer, and a plastic flow regulator. Maximum operating temperature 60°C.
Shower kit consisting of a wall mounted elbow (brass body various finishes - see model), shower hose and handset. The outlet of the wall elbow incorporates a single check valve cartridge, however, the complete product has not been fully tested to demonstrate it provides backflow protection. The shower handset inlet incorporates a stainless-steel strainer and a plastic flow regulator. Maximum operating temperature 60°C.
Range of shower outlets and shower handsets. The shower heads have a brass body and ball joint, NBR ‘O’-ring, stainless-steel strainer and silicon nozzles. The shower handset has a brass body, NBR ‘O’-rings, silicon nozzles and incorporate a plastic flow regulator on the inlet. Model ‘100274774 N200000068’ is supplied with a double interlocked hose and a single check valve cartridge (to be installed on the inlet to the hose) however the complete product has not been fully tested to demonstrate it provides backflow protection. Model ‘100274774 N200000068’ has a maximum operating temperature of 60°C. All other models have a maximum operating temperature of 85°C.
Range of bib taps incorporating brass bodies. The BTHUCV1/2 and BTHUCV3/4 models incorporate an approved single check valve cartridge on the inlet and the outlet (hose union), however, the complete product has not been fully tested to demonstrate it provides backflow protection. The BTHUCV1/2 and BTHUCV3/4 models also incorporate a drain port. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.
Range of pillar taps incorporating brass bodies (various finishes), quarter turn ceramic disc headworks and various operating members. Spout outlets incorporate either a plastic aerator or flow straightener (all models apart from STA13-QT). Fittings are supplied with metal backnuts Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.
Range of pillar taps with brass bodies (various finishes) incorporating non-rising spindle headworks using either dome type or cross top operating members. Spout outlets incorporate plastic flow straighteners. The products are also supplied with metal back nuts. Maximum working pressure 10.0 Bar. Maximum operating temperature 85°C.
Self-closing basin pillar tap (chromium plated brass) with spring loaded headwork and dome type operating members. The spout outlet incorporates a chrome plated plastic flow straightener. The product is supplied with metal backnuts. Maximum working pressure 10.0 Bar. Maximum operating temperature 60°C.
Range of flexible shower hoses incorporating a PVC inner lining, corrugated stainless steel outer layer (various finishes) and silicone washers. Maximum operating temperature 65°C.
Range of shower hoses with PVC outer (various finishes - see model), PET reinforcement layer, PVC inner liner and EPDM washers. Maximum operating temperature 65°C.
Range of stainless steel, PVC and nylon braided shower hoses (various finishes), incorporating PVC, EPDM or PEX liners and various end connections.
Range of wall mounted, exposed, thermostatic shower mixing valves with brass bodies (various finishes - see model) incorporating a quarter turn ceramic disc headwork controlling the flow with a dome type operating member. The temperature is controlled independently via a thermostatic cartridge with a dome type operating member that also incorporates a manual override button. Both inlets incorporate a combined NBR washer and stainless-steel strainer, as well as an approved single check valve cartridge, however, the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.
Range of adjustable T-type thermostatic mixing valves with brass bodies (chrome plated). Each inlet incorporates a stainless steel strainer and an approved check valve cartridge, however the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum working pressure 10.0 bar. Maximum operating temperature 85°C.
T-type mixing valve with a DZR brass body (nickel plated), temperature is controlled by a thermostatic cartridge. Each inlet incorporates a combined EPDM washer and stainless steel strainer, and a single check valve cartridge, verified by test (suitable for backflow protection against Fluid Category 2). For use with copper pipe manufactured to EN1057. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.
T-type mixing valve with a DZR brass body (nickel plated), temperature is controlled by a thermostatic cartridge. For use with copper pipe manufactured to EN1057. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.
Range of wall mounted, bar type, thermostatic shower blending valves (chromium plated brass), incorporating a ¼ turn ceramic disc headwork controlling the flow with a dome type operating member. The temperature is controlled independently via a thermostatic cartridge with a dome type operating member incorporating a manual override button. Both inlets incorporate a stainless steel strainer and an approved check valve cartridge, however the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum working pressure 10.0 bar. Maximum operating temperature 65°C.
Range of wall mounted, concealed, thermostatic shower valves with brass bodies and trim sets (various finishes - see models). Flow is controlled as follows (for operating members - see model): Single outlet models: ¼ turn ceramic disc headwork. Double Outlet Models without diverter: ¼ turn ceramic disc headworks. Double Outlet Models with diverter: 2-way ceramic disc diverter headwork. Triple Outlet Models with diverter: ¼ turn ceramic disc headwork and a 2-way ceramic disc diverter headwork. The temperature is controlled independently via a thermostatic cartridge with various operating members (see model) which incorporates a manual override button. The inlets incorporate a single check valve cartridge, however, the complete assembly has not been tested to demonstrate it provides backflow protection. Specific models are supplied with a shower hose and handset (see models). Maximum working pressure 5.0 Bar Maximum operating temperature 60°C
Wall mounted bar type thermostatic mixing valve (chromium plated brass) incorporating a ¼ turn ceramic disc headwork controlling the flow with a dome type operating member and a secondary ceramic disc headwork diverting the flow between the overhead shower and hand shower with a single lever operating member. The temperature is controlled independently via a thermostatic mixing cartridge with a dome type operating member that incorporates a manual override button. Both inlets incorporate single check valve cartridges, however, the complete assembly has not been tested to demonstrate it provides backflow protection. The product is supplied with a fixed overhead shower, shower handset and hose. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.
Wall mounted, concealed, 2-way diverter valve (brass body and chrome trim set) with a single lever operating member. Maximum working pressure 5.0 bar. Maximum operating temperature 65°C.
Manually adjustable pressure reducing valve, which incorporates a DZR brass body and an in-line double check valve assembly on the inlet (verified by test as suitable for backflow protection against Fluid Category 3). The outlet incorporates a shut-off valve. Maximum supply pressure 16.0 bar. Maximum outlet pressure between 1.5 bar and 6.0 bar. Maximum operating temperature 40°C.
Range of 5 way inlet control group assembly incorporating a DZR brass body incorporating a pressure reducing valve, with an adjustable outlet pressure range of either 3.0 bar, 3.5 bar, or 6.0 bar and a safety relief valve set at either 6.0 bar or 8.0bar (depending on model). The product incorporates an inline single check valve cartridge after the balanced cold take off, verified by test (suitable for backflow protection against Fluid Category 2). Maximum supply pressure 10.0 bar. Maximum operating temperature 85°C
Range of adjustable, pilot operated, pressure reducing control valves with black plastic bodies, EPDM diaphragm, EPDM ‘O’-rings and NBR seals. The products are supplied with auxiliary stainless-steel tubing, lever operated spherical valves, integral stainless-steel strainer, pilot valve and a quarter turn ceramic disc valve. Maximum inlet supply pressure 16.0 bar. Maximum outlet pressure 0 - 8.5 bar, 7.0 - 13.5 bar or 12.0 - 16.0 bar (see model). Maximum operating temperature 60°C.
Range of pre-set, spring loaded, angled pressure relief valves with plastic body and EPDM diaphragm. The valves are fitted with rotary type easing gear . For maximum working pressure please refer to model. Maximum operating temperature 99°C.
Range of latching and normally closed (see model) solenoid valves with plastic bodies, NBR diaphragms and ‘O’-rings. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C
Range of servicing valves incorporating brass bodies (chrome plated or natural brass) The P2290 & P2290SI models are spherical valves with brass balls. The 201210 A-80 model is quarter turn with an EPDM seat and ‘O’-ring. The NF721 & NF721SI models are quarter turn with a NBR seat and EPDM ‘O’-ring. The 00711 A-80 is quarter turn with a NBR seat and ‘O’-rings. Maximum working pressure 16.0 bar. Cold water use only.
Range of lever operated spherical valves incorporating brass bodies (chrome plated), brass balls and PTFE seals. Maximum working pressure 40.0 bar. Maximum operating temperature 100°C.
Flow through valve with a brass body and EPDM ‘O’-rings, incorporating a spherical valve and a separate drain port/plug. Maximum working pressure 10.0 bar. Maximum operating temperature 65°C.
Range of gate valves with blue epoxy coated ductile iron bodies and EPDM coated ductile iron wedges. The valves are operated via a non-rising spindle with a hand wheel operating member. Maximum working pressure 16.0 bar. Maximum operating temperature 85°C.
Range of cold water inlet control groups with DZR brass bodies, consisting of a pressure reducing valve, (all models are adjustable between 1.0 and 6.0 bar, but some come pre-set from the factory - see model), a pressure relief valve (set at 6.0 or 8.0 bar - see model) and a single check valve cartridge, verified by test (suitable for backflow protection against Fluid Category 2). The pressure relief valve is fitted with a rotary type easing gear. All products for use with copper pipe manufactured to BS EN 1057. Maximum inlet supply pressure 20.0 bar. Cold water use only.
Range OF JLA commercial washing machines with flow controlled by solenoid valve and discharged via a type `AB` airgap (verified by test - suitable for backflow protection against fluid category 5). The products are supplied with three ¾” x ¾” BSP (F) double check valve assemblies (suitable for backflow protection against Fluid Category 3) for installation on each inlet prior to a HDPE inlet hose with ¾” x ¾” captive nut end connections. Maximum working pressure 5.7 Bar. Maximum operating temperature 60°C.
Range of commercial front loading, hood type & utensil washer type dishwashing machines with flow controlled by solenoid and discharged via type AB air gap (verified by test - suitable for backflow protection against fluid category 5) . The products are supplied with a grey coloured PVC supply hose. Maximum working pressure 6.0 bar. Maximum operating temperature 90°C.
`Hy-MAG` range of electromagnetic water conditioners with blue PTFE coated bodies. Maximum working pressure 16.0 bar. Maximum operating temperature 65°C.
Range of electrolytic water conditioners, with a brass body and zinc alloy anodes. Maximum working pressure 16.0 bar. Maximum operating temperature 85°C.
Range of domestic, salt regenerated ion exchange water softeners. Maximum working pressure 6.0 bar. Cold water use only.
Range of domestic, salt regenerated ion exchange water softeners. Maximum working pressure 6.0 bar. Cold water use only.
'Droople DRP-M90-IMP'. White coloured, injection moulded acetal cogwheel. For use with water up to 65°C.
Injection moulded POM materials. 'POMM90-BK02' is black coloured and for use with water up to 60°C. ‘POMM90-GR05 & POMM90-GR37’ are grey coloured and were added to the approval in November 2022, they are for use with water up to 85°C.
'ABS757BK' (black coloured) & 'ABS757GY' (grey coloured). Injection moulded ABS materials. For use with water up to 65°C.
'BPL HB QD Bitumen Black 60'. Factory applied, black coloured bituminous coating. Apply and cure as per manufacturer's data sheet number '671' dated 'Apr-20'. For use with water up to 60°C.
'42.5 (HSR)'. Factory applied, grey coloured sulphate resistant cement. Mix cement:sand:water in a 1.5:1:0.4 mass ratio. Cure for 8 hours@23°C. For use with water up to 65°C. This material is only approved for the mixing and curing conditions that appear on the approval. If the mixing and/or curing conditions are varied from those specified on the approval then the material is not covered by the scope of the approval.
'SW-02'. Factory applied, grey coloured cement mortar. Mix sand, water & cement in a 1.5:1.0:1.0 weight ratio. Cure for 24 hours@25°C. For use with water up to 65°C. This material is only approved for the mixing and curing conditions that appear on the approval. If the mix and/or cure conditions are varied from those specified on the approval then the material is not covered by the scope of the approval.
'Aquafitting Blue'. Factory applied, blue coloured epoxy coating. Apply and cure as per manufacturer's instructions file number 'DLCHB-CO-001', edition 'A1', issue date '2021-April-11st'. For use with water up to 65°C.
'EPOKIM Painting System'. Factory applied, dark green coloured (once top coat applied), two-component epoxy coating comprising of a primer and top coat. The primer (EPOX code A0768.N05133 + cat.A0918.N00100) consists of a catalyst and hardener which should be mixed in a 100:43 volume ratio before applying two coats in accordance with instructions ‘W1_2021_00’ dated ‘25/10/2021’. Cure (flash-off) for 40 minutes@40°C. The top coat (EPOKIM HS code A0435.N02038 + cat.A0904.N00000) consists of a catalyst and hardener which should be mixed in a 100:16 volume ratio before applying one coat in accordance with instructions ‘W1_2021_00’ dated ‘25/10/2021’. Cure (flash-off) for 10 minutes@20°C. The complete system should then be ‘stoved’ for 60 minutes@70°C. For use with water up to 23°C.
'ENDOPRENE®84-30 THIXO'. Factory applied, cream coloured two-part polyurethane coating consisting of a resin and hardener. Mix and apply as per manufacturer`s technical data sheet (version dated 16/12/2019). Cure for 48 hours at 20°C. For use with water up to 55°C. This material is only approved for the curing conditions that appear on the approval. If the cure conditions are varied from those specified on the approval then the material is not covered by the scope of the approval.
'XFGJ-2'. Factory applied, grey coloured sulphate resistant cement. Mix cement:sand:water in a 1.5:1:0.4 mass ratio. Cure for 8 hours@23°C. For use with water up to 65°C. This material is only approved for the mixing and curing conditions that appear on the approval. If the mixing and/or curing conditions are varied from those specified on the approval then the material is not covered by the scope of the approval.
'Cepox P05/95'. Factory applied, two part, yellow coloured epoxy coating. Mix and apply as per Technical Data Sheet dated 19/11/2021. Cure for 16 hours@70°C. For use with water up to 85°C. This material is only approved for the curing conditions that appear on the approval. If the cure conditions are varied from those specified on the approval then the material is not covered by the scope of the approval.
'Kerjiwal SRC'. Factory applied, grey coloured Sulphate Resisting Cement. Mix cement, sand & water in a volume ratio of 1:1.2:0.5. Cure for 28 days@32°C. For use with water up to 65°C. This material is only approved for the mixing and curing conditions that appear on the approval. If the mix and cure conditions are varied from those specified on the approval then the material is not covered by the scope of the approval.
'MS519'. Factory applied, blue coloured Porcelain Enamel coating. Apply as per manufacturer's instructions dated 2021.6.23. Dry for 2 hours@100°C before firing for 10 minutes@860°C For use with water up to 75°C. This material is only approved for the drying and firing conditions that appear on the approval. If the drying and/or firing conditions are varied from those specified on the approval then the material is not covered by the scope of the approval.
`Belzona 1321`. Site applied, two-part, epoxy amine coating available in grey or blue colours. Mix base and hardener in a 11:1 mass ratio. Apply and cure as per manufacturer’s IFU ‘FN10026’, publication number ’02-09-21’. For use with water up to 23°C. These materials are only approved for the mixing conditions that appear on the approval. If the mixing conditions are varied from those specified on the approval then the materials are not covered by the scope of the approval.
‘Sikalastic®-6100 FX White’ (formerly known as ‘MasterSeal 6100 FX White’) ‘Sikalastic®-6100 FX Grey’ (formerly known as ‘MasterSeal 6100 FX Grey’. Site applied, two-component cementitious coating. Mix ‘Sikalastic®-6100 FX White’ (Coat 1) with water in a mass ratio of 15:5.6. Apply and cure for 1 day@5°C before applying Coat 2. Mix ‘Sikalastic®-6100 FX Grey’ (Coat 2) with water in a mass ratio of 15:5.6. Apply and cure for 5 days@5°C. For use with water up to 23°C. This material is only approved for the mixing and curing conditions that appear on the approval. If the mix and/or cure conditions are varied from those specified on the approval then the material is not covered by the scope of the approval.
'Tesnit BA-60'. Orange coloured aramid fibre/NBR gasket material. For use with water up to 85°C. For use only as a gasket material having been tested at a reduced surface area to volume ratio.
`Novapress 260`. Green coloured, compressed fibre material (bound with NBR), manufactured by calendaring. For use with water up to 85°C. For use only as a jointing/gasket material having been tested at a reduced surface area to volume ratio.
'Acquablu Hose'. Extruded hose comprising of a white coloured (transparent) polyethylene inner layer, off-white coloured chlorobutyl second layer, rayon reinforcement layer and blue coloured bromobutyl outer later. For use with water up to 60°C.
'TUCAI WRAS EPDM hose'. Black coloured, extruded EPDM hose. Shore hardness 80. Tested in-radius size 0.68mm. For use with water up to 70°C.
'Super Lube'. Colourless (transparent) lubricant. Apply as per manufacturer's instructions. For use with water up to 65°C.
'Ultramid A3EG7 FC Aqua Uncoloured'. Natural (appears beige), injection moulded, PA66 polyamide material. For use with water up to 65°C.
'Badadur PBT8 GK30 Graphit 371'. Grey coloured, injection moulded PBT material. For use with water up to 65°C.
'Avaspire AV-621 NT'. Natural (appears beige, opaque), injection moulded PEEK material. For use with water up to 85°C.
'Aion MDPE Pipe'. Blue coloured, extruded MDPE pipe. For use with water up to 65°C.
'Aion HDPE Pipe'. Black coloured (with blue stripe), extruded HDPE pipe. For use with water up to 65°C.
'CONTINUUM DGDA-2610 BK'. Black coloured, compression moulded HDPE (PE100) material. For use with water up to 23°C.
'TASNEE 100 Black'. Black coloured HDPE material manufactured in Saudi Arabia and Germany, for injection moulding and extrusion purposes. For use with water up to 60°C.
'TORELINA A673MWRB'. Dark grey coloured, injection moulded PPS material. For use with water up to 85°C.
'Floraseal'. White coloured PTFE tape manufactured by press strip roller. For use with water up to 60°C.
'Unecol CINTAS'. White coloured PTFE tape manufactured by press strip roller. For use with water up to 60°C.
'S-9028'. Black coloured, compression moulded EPDM rubber material Shore hardness 60 ShA. Tested in-radius size 1.0mm. For use with water up to 60°C.
'EBW-65'. Black coloured, compression moulded EPDM rubber material. Shore hardness 65. Tested in-radius size 0.98mm. For use with water up to 85°C.
'RCI EP 70'. Black coloured, compression moulded EPDM material. Shore hardness 70. Tested in-radius size 0.95mm. For use with water up to 65°C.
'HYPRESS12V'. Black coloured, compression moulded EPDM material. Shore hardness 70. Tested in-radius size 1.1mm. Between June 2021 and August 2022, the material was for use with water up to 23°C. Between September 2022 and June 2026, the material is for use with water up to 65°C.
'S/EP-50, S/EP-60, S/EP-70 & S/EP-80'. Black coloured, compression moulded EPDM materials with a shore hardness of between 50A & 80A. Tested in-radius size 1.05mm. For use with water up to 65°C.
'EPDM-W E267'. Black coloured, compression moulded EPDM material. Shore hardness 80A. Tested in-radius size 1.0mm. For use with water up to 85°C.
'OLDAL VMQ880 65TR – VMQ4303'. Colourless (translucent), extruded VMQ rubber material. Shore hardness 75. Tested in-radius size 1.0mm. For use with water up to 85°C.
'TEC S147 R.-45 ROSSO'. Orange coloured, injection moulded, silicone rubber 'O' rings & gaskets. Shore hardness 45. Tested in-radius size between 0.5mm & 2.6mm. For use with water up to 85°C.
'SB1 Bonding Agent'. Factory applied, black coloured bonding agent intended to bond plastic or brass to rubber. Apply and cure as per manufacturer's instructions 'LDAP-003 issue 1' dated 11-08-2016. For use with water up to 85°C.
'Key Plumb'. Clear, transparent (un-pigmented) solvent cement, (intended to join PVC pipe and fittings). Apply as per manufacturer's instructions. Cure for 20 days at 7°C. For use with water up to 65°C. This material is only approved for the curing conditions that appear on the approval. If the cure conditions are varied from those specified on the approval then the material is not covered by the scope of the approval.
'DESTONE DSC7500G6'. Black coloured, injection moulded polyketone material. For use with water up to 85°C.
'Novodur® SBM-90 Q203'. Natural (appears off-white), injection moulded thermoplastic resin. The natural material may be coloured using the following INEOS Styrolution colourants at the agreed maximum percentage concentrations by weight: Pigment White 6, Black 7, Blue 15:3, Blue 29, Brown 24, Red 101, Violet 15, Green 7, Green 17 & Yellow 53. For use with water up to 60°C.
'Novodur® SBM-90'. Natural (appears off-white), injection moulded thermoplastic resin. The natural material may be coloured using the following INEOS Styrolution colourants at the agreed maximum percentage concentrations by weight: Pigment White 6, Black 7, Blue 15:3, Blue 29, Brown 24, Red 101, Violet 15, Green 7, Green 17 & Yellow 53. For use with water up to 60°C.
Deck mounted single hole, single outlet (fixed) electronically controlled tap assembly (chromium plated brass). The flow is controlled by a solenoid valve activated via an infra-red sensor. The spout outlet incorporates a plastic aerator. Tempearture is controlled from a separate control unit incorporating a thermostatic cartridge, which is operated by a single lever on the side of the unit. The spout connects to the unit via a (transparent) PEX-b pipe. The inlets of the control unit incorporate a stainless steel strainer and an approved check valve cartridge, however, the complete product has not been fully tested to demonstrate it provides backflow protection. The outlet of the unit incorporates a plastic flow regulator. Maximum working pressure 10.0 bar. Maximum operating temperature 65°C.
BS1212-4 (2016) compact type float operated valve for WC flushing cisterns, side entry type. The inlet incorporates a plastic flow restrictor. Maximum working pressure 10.0 bar. Cold water use only.
Range of WC flushing cisterns incorporating a BS 1212-4 (2016) side entry compact type float operated inlet valve providing a Type AG air gap with a dual flush drop valve for full flush volumes of up to 6 litres and a reduced flush of up to 4 litres or 4.5/3 litre flush volumes. The cistern is operated by a manual push button and the product incorporates a servicing valve on the inlet supply. Maximum working pressure 10.0 bar. Cold water use only.
WC flushing cistern incorporating a side entry compact type float operated inlet valve providing a Type AG air gap with a dual flush drop valve for full flush volumes of up to 6 litres and a reduced flush of up to 4 litres. The cistern is operated by a manual push button and incorporates a servicing valve on the inlet supply. Maximum working pressure 10.0 bar. Cold water use only.
Concealed WC dual flushing cistern with a BS 1212-4 (2016) float operated inlet valve providing a Type AG air gap arrangement and a dual flush pneumatic outlet valve. The flush volume is operated by a two-push button assembly for a 6 or 3 litre flush volume. Maximum working pressure 10.0 bar. Cold water use only.
Range of check valve cartridges with plastic bodies to be housed in specifically dimensioned bodies. The product incorporates a plastic flow regulator. Maximum working pressure 16.0 bar & maximum operating temperature 65°C.
Range of single check valve assemblies with DZR brass bodies. Maximum working pressure 16.0 bar. Maximum operating temperature 85°C.
Non- verifiable double check valve assembly consisting of two spring loaded resilient trim in-line check valve cartridges housed in a chrome plated DZR brass body with an integral insolation valve between the cartridges. For use with copper pipes to EN1057. Maximum working pressure 10.0 bar. Maximum operating temperature 85°C.
Range of non-verifiable double check valve assemblies (DZR brass bodies) incorporating spherical valves and either red or blue butterfly handles. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.
A ceramic cartridge headwork with a plastic body and EPDM ‘O’-rings for insertion into specifically dimensioned assemblies. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.
Range of ceramic cartridge headworks incorporating NBR ‘O’ rings and silicone seals. For insertion into specifically dimensioned tap assemblies. Maximum working pressure 10.0 bar. Maximum operating temperature 85°C.
Thermostatic cartridge incorporating brass body (chrome plated), stainless steel strainers and EPDM ‘O’-rings. For insertion into specifically dimensioned tap bodies. Maximum working pressure 10.0 bar. Maximum operating temperature 65°C.
Range of thermostatic cartridges incorporating plastic bodies, stainless steel filters and EPDM ‘O’-rings. For insertion into specifically dimensioned bodies. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.
Range of single hole, single outlet (fixed) combination tap assemblies with brass bodies (various finishes), incorporating a ceramic cartridge headwork with a single lever operating member. The spout outlet has a plastic aerator and model 31 531 XXX is supplied with a pop-up waste. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.
Range of single hole, single outlet (fixed) combination tap assemblies with brass bodies (chrome plated) incorporating a joystick controlled ceramic cartridge headwork. The spout outlets incorporate a plastic aerator. Models 39 031 xxx & 39 035 xxx are supplied with lever operated pop-up wastes and model 39 032 xx is supplied with a pop-up waste kit. Maximum working pressure: 10.0 bar. Maximum operating temperature 60°C.
Range of single hole, single outlet (fixed) combination tap assemblies with brass bodies (various finishes ), incorporating a ceramic cartridge headwork with a single lever operating member. The spout outlet incorporates a plastic aerator. Fittings are supplied with click type wastes. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.
Single hole, single outlet fixed combination tap assembly (chromium plated brass), incorporating a ceramic cartridge headwork with a single lever operating member. The spout outlet incorporates a plastic flow straightener. The product is supplied with a click type pop-up waste. Maximum operating pressure 10.0 bar. Maximum operating temperature 60°C
Range of single hole, single outlet fixed combination tap assemblies (chromium plated brass), incorporating a ceramic cartridge headwork with a single lever operating member. The spout outlet incorporates a plastic aerator. Maximum operating pressure 10.0 bar. Maximum operating temperature 60°C
Range of single hole single outlet fixed combination tap assemblies (chromium plated brass) incorporating ceramic cartridge headworks with single lever operating members. The product incorporates a plastic flow regulator in the spout body, and a plastic aerator in the spout outlet. Certain models are supplied with click type waste (See models). Maximum working pressure 10 bar. Maximum working temperature 60 °C.
Range of single hole, single outlet (fixed) combination tap assemblies (chromium plated brass) incorporating a ceramic cartridge headwork with a single lever operating member. The spout outlet incorporates a plastic aerator. Products are supplied with a pop-up waste. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.
Range of single hole, single outlet (fixed) combination tap assemblies (chromium plated brass) incorporating a ceramic cartridge headwork with a single lever operating member. The spout outlet incorporates a plastic aerator. Products are supplied with a pop-up waste. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.
A range of single-hole, single outlet, (swivel) combination tap assemblies with brass bodies (chrome plated), incorporating ceramic cartridge headworks with single lever operating members. The spout outlet incorporates a plastic aerator. Maximum working pressure 5.0 bar. Maximum working temperature 60°C.
Range of single hole, single outlet (swivel) combination tap assemblies with brass bodies (chrome plated). Incorporating quarter turn ceramic disc headworks with single lever operating members (model 922069) and non-rising spindle headwork with dome type operating members (model 922039. The spout outlet incorporates a plastic flow straightener. Maximum working pressure 6.0 bar. Maximum operating temperature 60°C.
Range of single-hole, single outlet, swivel combination tap assemblies (chromium plated brass), incorporating a ceramic cartridge headworks with a single lever operating member. The spout outlet incorporates a plastic flow straightener. The product is supplied with a fixing kit that incorporates isolation valves with single check valve assemblies (verified by test - suitable for backflow protection against fluid Category 2). Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.
Range of single hole, single outlet (swivel) combination tap assemblies incorporating a ceramic cartridge headworks with single lever operating members. The spout outlet incorporates a flow straightener. Supplied with optional aerator. Maximum working pressure 10.0 bar. Maximum operating temperature 65°C
Single hole, single outlet (swivel) combination tap assembly with brass body (chrome plated), incorporating a ceramic cartridge headwork and single lever operating member. The spout outlets incorporate a plastic flow straightener. Maximum working pressure 10.0 bar. Maximum operating temperature 60ºC.
Single hole, single outlet (swivel) combination tap assembly (stainless steel). Incorporating ceramic cartridge headwork with a single lever operating member. The spout outlet incorporates a plastic aerator. Maximum working pressure 5.5 bar. Maximum operating temperature 60°C.
Single hole, single outlet (swivel) combination tap assembly (chromium plated brass), Incorporating a ceramic cartridge headwork with lever type operating member. The spout outlet incorporates a plastic aerator. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C
Single hole, single outlet (swivel) combination tap assembly with brass body (chrome plated), incorporating quarter turn ceramic disc headworks with a single lever type operating members. The outlet incorporates a plastic flow straightener. Maximum working pressure 5.5 bar. Maximum operating temperature 60°C.
Single hole, single outlet (swivel) combination tap assembly with brass body (chrome plated), incorporating ceramic cartridge headwork and single lever operating member. The spout outlet incorporates a plastic aerator. The cold water inlet incorporates an approved check valve cartridge, however, the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.
Single hole, single outlet (swivel) combination tap assembly (chromium plated brass), incorporating quarter turn ceramic disk headworks with single leaver operating members. The spout outlet incorporates a plastic aerator. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.
Range of single hole, single outlet (swivel) combination tap assemblies (chrome plated brass), incorporating quarter turn ceramic disc headwork. The spout outlet incorporates a plastic flow straightener and the product is supplied with single check valve assemblies (verified by test as suitable for backflow protection against Fluid Category 2) with integral servicing valve for both inlets. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C
Single hole, single outlet (swivel) combination tap assemblies (chromium plated brass), incorporating a ceramic cartridge headwork with a single lever operating member The spout outlets incorporate a plastic aerator. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.
Range of single hole, single outlet (swivel) combination tap assemblies (chromium plated brass) incorporating a ceramic cartridge headwork with a single lever operating member. The spout outlet incorporates a plastic aerator. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.
Single hole, single outlet (swivel) combination tap assembly (chromium plated brass), incorporating quarter turn ceramic disk headworks with single leaver operating members. The spout outlet incorporates a plastic aerator. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.
Range of single hole, single outlet (swivel) combination tap assemblies with brass bodies (various finishes), incorporating ceramic cartridge headworks and single lever operating members. The spout outlet incorporates a plastic aerator. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.
Range of wall mounted, two-hole, single outlet (fixed) concealed combination tap assemblies (chromium plated brass) incorporating a ceramic cartridge headwork with single lever operating members. The spout outlet incorporates a plastic aerator. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.
Two-hole, single outlet fixed combination tap assembly (chromium plated brass) incorporating quarter turn ceramic disc headworks with single lever operating members. The spout outlet incorporates a stainless steel strainer with a plastic flow straightener. The product is supplied with metal back nuts. The inlets incorporate an approved check valve cartridge, however, the complete product has not been fully tested to demonstrate it provides backflow protection Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.
Range of two-hole, single outlet, fixed combination tap assemblies (chromium plated brass) incorporating quarter turn ceramic disc headworks with single lever operating members. The spout outlet incorporates a plastic flow straightener. The product is supplied with metal back nuts. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.
Two-hole, single outlet combination tap assembly (chromium plated brass), incorporating quarter turn ceramic disc headworks with single lever operating members. The spout outlet incorporates a plastic flow straightener. The product is supplied with metal back nuts. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.
Two-hole, single outlet, fixed combination tap assembly (chromium plated brass) incorporating ceramic disc headworks with single lever operating members. The product incorporates a waterfall type spout with a stainless steel mesh strainer. The product is supplied with metal back nuts. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C
Two-hole, single outlet (fixed) combination tap assemblies (chromium plated brass). Incorporating quarter turn ceramic disc headworks with cross-top type operating members and manually operated diverter to shower outlet with a single lever operating member. The product is supplied with a shower hose and handset. The product is also supplied with metal backnuts. Maximum working pressure 10 bar. Maximum operating temperature 60°C
Range of two-hole, single outlet (fixed) combination tap assemblies (chromium plated brass), incorporating quarter turn ceramic disc headworks with single lever operating members or non-rising spindle headworks with dome type operating members (922036 model only) and a self-cancelling diverter to shower outlet. The spout outlet incorporates a plastic flow straightener. The 922308 and 922317 models are also supplied with an optional plastic aerator. The products are supplied with a shower hose and handset and metal back nuts. Maximum working pressure 6.0 bar. Maximum operating temperature 60°C.
Two-hole, single outlet (fixed) combination tap assembly (chromium plated brass), incorporating quarter turn ceramic disc headworks with single lever operating members and a self-cancelling diverter to shower outlet. The spout outlet incorporates a plastic flow straightener. The product is supplied with a shower hose and handset and metal back nuts. Maximum working pressure 6.0 bar. Maximum operating temperature 60°C.
Two hole, single outlet (fixed) combination tap assembly with brass body (various finishes). Incorporating quarter turn ceramic disc headworks, and self cancelling diverter to shower outlet. The inlets incorporate approved check valve cartridges, however, the complete product has not been fully tested to demonstrate it provides backflow protection. The spout outlet incorporates a plastic aerator. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.
Range of wall mounted two hole, single outlet (fixed) combination tap assemblies (chromium plated brass), incorporating a ceramic cartridge headworks with single lever operating member and self-cancelling diverter to shower outlet. The inlets incorporate a stainless steel strainer and an approved check valve cartridge, however, the complete product has not been fully tested to demonstrate it provides backflow protection. The spout outlet incorporates a plastic aerator. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.
Range of floor mounted, two-hole, single outlet (swivel) combination tap assemblies (stainless steel and brass bodies various finishes), incorporating a ceramic cartridge headwork with a single lever operating member. The spout outlet incorporates a plastic aerator. Maximum working pressure 5.0 Bar Maximum operating temperature 70.0°C
Range of two hole, single outlet (swivel) combination tap assemblies with brass bodies (chrome plated). Incorporating non-rising spindle headworks with dome type operating members (model 922040) and ceramic disc headwork with single lever operating members (model 922075). The spout outlet incorporates a plastic flow straightener. Maximum working pressure 6.0 bar. Maximum operating temperature 60°C.
Two-hole, single outlet fixed combination tap assembly (chromium plated brass) incorporating quarter turn ceramic disc headworks with single lever operating members and a lockable self-cancelling diverter to shower outlet. The spout outlet incorporates a plastic flow straightener The product is supplied with a shower hose and handset and metal backnuts. Maximum working pressure 10.0 bar. Maximum working temperature 60°C.
Range of three-hole, single outlet (fixed) combination tap assemblies incorporating brass bodies (various finishes), quarter turn ceramic disc headwork and choice of single lever or dome type operating members. The spout outlets incorporate a plastic aerator. The product is supplied with stainless steel braided PEX lined flexible hose assemblies for connecting the side body headworks and the spout junction. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.
Range of wall mounted, three-hole, single outlet (fixed) combination tap assemblies (chromium plated brass spout and trim set), incorporating quarter turn ceramic disc headworks with dome type operating members. The inlet of the spout incorporates a plastic flow regulator, and the spout outlet incorporates a plastic aerator. Maximum working pressure 10 bar. Maximum operating temperature 60°C.
Range of three-hole, single outlet, (fixed) combination tap assemblies with brass bodies (chromium plated), incorporating quarter turn ceramic disc headworks with dome type operating members. The product is supplied with stainless steel braided PEX lined flexible hose assemblies for connecting the side body headworks and the spout junction. The spout inlet incorporates a plastic flow restrictor, and the spout outlet incorporates plastic aerator. The products are supplied with click type pop-up waste. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.
Range of wall mounted, three-hole, single outlet (fixed) combination tap assemblies (various finishes, see models) incorporating quarter turn ceramic disc headworks with wheel type operating members. The spout outlet incorporates a plastic aerator. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.
Range of three-hole, single outlet (fixed) combination tap assemblies with brass bodies (chrome plated). Incorporating quarter turn ceramic disc headworks and single lever operating members. The spout outlet incorporates a plastic aerator and is connected to the headworks via stainless steel braided PEX lined hose assemblies. Model 65011 and 65012 are supplied with a pop-up waste. Maximum working pressure 5.0 Bar. Maximum operating temperature 60°C.
Range of three hole, single outlet (fixed) combination tap assemblies with brass bodies (various finishes - see model), incorporating quarter turn ceramic disc headworks with various operating members (see models). The products are supplied with two stainless steel braided EPDM lined flexible hose assemblies with ½” captive nut end connections for installation between the side valves and the spout. The spout outlet incorporates a plastic aerator. Maximum working pressure 3.0 bar. Maximum operating temperature 60°C.
Three hole, single outlet (fixed) combination tap assembly with a brass body (various finishes - see model), incorporating quarter turn ceramic disc headworks with single lever operating members. The products are supplied with two stainless steel braided EPDM lined flexible hose assemblies with ½” captive nut end connections for installation between the side valves and the spout. The spout outlet incorporates a combined plastic aerator. Maximum working pressure 3.0 bar. Maximum operating temperature 60°C.
Range of three-hole, single outlet (fixed) combination tap assemblies with brass bodies (chrome plated). Incorporating quarter turn ceramic disc headworks and single lever operating members. The spout outlet incorporates a plastic aerator and is connected to the headworks via stainless steel braided PEX lined hose assemblies. Model 65015 is supplied with a pop-up waste. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.
Range of three hole, single outlet (fixed) combination tap assemblies (chromium plated brass), incorporating quarter turn ceramic disc headworks and single lever operating members. The product is supplied with stainless steel braided PEX lined flexible hose assemblies with M8 x ⅜” captive nut end connections and a combined NBR washer and stainless steel strainer (x2) for installation between the side valves and the brass tee piece to the spout. The inlets of the brass tee piece incorporate an approved single check cartridge, however, the complete product has not been fully tested to demonstrate it provides backflow protection. The product is supplied with two loose fibre gaskets for installation on each inelt hose. The spout outlet incorporates a plastic aerator. Maximum working pressure 5.0 bar Maximum operating temperature 60°C
Rangle of three-hole, single outlet (fixed) combination tap assemblies with brass bodies (various finishes), incorporating ceramic cartridge headworks with single lever operating members and self-cancelling diverter to shower outlet The spout outlets incorporate a plastic aerator is connected to the headworks via stainless steel braided PEX lined hose assemblies. Product is supplied with a shower hose and handset. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.
Four-hole, single outlet (fixed) combination tap assembly (various finishes). Incorporating quarter turn ceramic disc headworks, with various operating members. interconnecting flexible hoses. The spout outlet incorporates a self-cancelling diverter to the shower outlet and a plastic flow straightener with stainless steel mesh strainer. The product is supplied with a shower handset that incorporates a single check valve cartridge; however, the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum working pressure 3.5 bar. Maximum operating temperature 60°C.
Range of four-hole, single outlet (fixed) combination tap assemblies (various finishes). Incorporating quarter turn ceramic disc headworks, with various operating members. interconnecting flexible hoses. The spout outlets incorporate a self-cancelling diverter to the shower outlet and a plastic flow straightener with a stainless-steel mesh strainer. The product is supplied with a shower handset that incorporates a single check valve cartridge; however, the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum working pressure 3.5 bar. Maximum operating temperature 60°C.
Range of four-hole, single outlet (fixed) combination tap assemblies (various finishes). Incorporating quarter turn ceramic disc headworks, with various operating members. interconnecting flexible hoses. The spout outlets incorporate a self-cancelling diverter to shower outlet and a plastic flow straightener with stainless steel mesh. The product is supplied with a shower handset that incorporates a single check valve cartridge; however, the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum working pressure 3.5 bar. Maximum operating temperature 60°C.
Range of floor mounted, single hole, single outlet fixed combination tap assemblies (chromium plated brass with a self-cancelling diverter to shower outlet. The product incorporates a ceramic cartridge headwork and single lever operating member. The spout outlets incorporate an aerator and the product is supplied with a hose and handset. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.
Range of wall elbows incorporating brass bodies (various finishes) and various back plates. Maximum operating temperature 95ºC.
Range of wall mounted spout outlets, (brass bodies with various finishes) incorporating a plastic aerator. Maximum operating temperature: 60°C
Range of wall mounted spout outlets incorporating brass bodies (various finishes) and plastic flow straighteners. Maximum working pressure 5.0 bar. Maximum operating temperature 65°C
‘CD3 Series’ chlorine dioxide dosing system incorporating a single check valve positioned at the point of injection. Maximum working pressure 6.0 bar. Cold water use only.
Range of expansion vessels with EPDM membrane and stainless steel flange connections. Models VB8, VB12, VB18 & VB24 have a maximum working pressure of 16.0 bar. All other models have a maximum working pressure of 10.0 bar. Maximum operating temperature 100°C.
Range of expansion vessels with stainless steel and epoxy coated carbon steel bodies incorporating a butyl rubber membrane. Maximum working pressure 10.0 bar. Maximum operating temperature 99°C.
Range of filling loop assemblies, comprising of a stainless steel braided EPDM lined hose, isolation valve with a DZR brass body and ball and an isolation valve with a DZR brass body and ball incorporating two check valve cartridges, verified by test (suitable for backflow protection against Fluid Category 3). The F1400120012211 model has an isolation valve incorporating two check valve cartridges, verified by test (suitable for backflow protection against Fluid Category 3) at each end of the filling loop. All items except the hoses are nickel plated. Maximum working pressure 10.0 bar. Maximum operating temperature 85°C.
Range of carbon block water filters and housings. Maximum working pressure 10.5 bar. Cold water use only.
Range of water filter housings with plastic heads and bodies (various colours - see model), incorporating NBR ‘O’-rings (158087/088/207/208/218/219/261 models only) or with EPDM ‘O’-rings (all other models). Big Blue for Cartridges - Maximum working pressure 6.9 bar (10” filter housings) and 6.2 bar (20” filter housings). Maximum working temp 38°C. All other models - Maximum working pressure 8.62 bar. Maximum working temp 52°C.
Carbon block filter cartridge with plastic body. The cartridge may be installed with a manifold (filter head) for use with PE tubing manufactured to BS 1972. Maximum working pressure 8.6 bar. Cold water use only
Carbon block filter cartridge with plastic body. The cartridge may be installed with a manifold (filter head) for use with PE tubing manufactured to BS 1972. Maximum working pressure 8.6 bar. Cold water use only
‘Comisa’ range of brass bodied press-fit and threaded fittings for use with `Comisa’ (PE-RT/AL/PE-LMD) multi-layer pipe. Maximum working pressure 10.0 bar. Maximum operating temperature 95°C.
Boss Range of brass, chrome plated brass or DZR brass compression fittings for use with copper pipe only. Maximum working pressure 16.0 bar. Maximum operating temperature 85°C.
Range of under-sink, electrically heated vented water heaters (cased and insulated). Maximum operating temperature 98˚C
Range of wall hung, gas-fired condensing combination boilers providing domestic hot water via a plate heat exchanger. The pressurised central heating system incorporates an expansion vessel and pressure relief valve set at 3.0 bar. The supplies to both domestic hot water and primary are controlled via spherical valves. The primary circuit has a maximum working pressure of 2.5 bar. The secondary circuit has maximum working pressure of 10.0 bar. Maximum supply temperature is 60°C. Maximum operating temperature of secondary circuit is 85°C.
Range of wall hung, gas-fired condensing combination boilers providing domestic hot water via a plate heat exchanger and pressure relief valve set at 3.0 bar. The supplies to both primary hot water and secondary are controlled via spherical valves. The boilers incorporate a filling loop assembly which incorporates a double check valve assembly (suitable for backflow protection against Fluid Category 3). Primary circuit: Maximum working pressure 2.5 bar. Maximum operating temperature 82°C. Secondary circuit: Maximum working pressure 10.0 bar. Maximum operating temperature 60°C
Hydraulic block assembly comprising a flow sensor, primary pump assembly, pressure relief valve preset at 3.0 bar and plate heat exchanger. Maximum working pressures: secondary = 10.0 bar and primary = 2.5 bar. Maximum operating temperature 80°C.
‘Aquila V4 C1’ range of water meters (brass or bronze bodies) with a plastic working chamber, flow regulator and impellor, and either NBR or EPDM ‘O’-rings. The products are supplied with loose NBR/fibre flange gaskets. Maximum working pressure 16.0 bar. Cold water use only.
A range of water meters incorporating brass or plastic bodies (See models), EDPM ‘O’-rings, plastic strainer on the inlet and a plastic impellor. Maximum working pressure 16.0 bar. Maximum working temperature 85°C (brass bodies) or cold water use only (plastic bodies)
Range of water meter manifolds (also known as double box valves) for use with MDPE pipe (manufactured to BS EN 12201). The products incorporate an approved check valve cartridge however, the complete product has not been fully tested to demonstrate it provides backflow protection Maximum working pressure 16 bar. Cold water use only.
Range of flow control valves for domestic hot water with plastic bodies and EPDM ‘O’-rings The products incorporate a motor which adjusts the flow, a flow sensor which measures the flow rate and a plastic filter on the inlet. Maximum working pressure 10.0 bar. Maximum operating temperature 65°C.
Pressure gauge with brass body and a plastic case. Maximum working pressure 16.0 bar. Maximum operating temperature 100°C
Range of flexible joints incorporating an EPDM (inner & outer) joint with a steel reinforcing ring and two carbon steel flanges. Maximum operating pressure 16.0 bar. Maximum operating temperature 65°C.
External pump docking station with a plastic body and NBR ‘O’ rings. Cold water use only.
Range of shower hoses and handsets (various finishes - see model) with EPDM ‘O’-rings. Maximum operating temperature 60°C.
Range of wall mounted shower kits, incorporating a shower handset, shower hose and wall elbow connection. Maximum operating temperature 60°C.
Range of shower columns with chromium plated brass bodies. Maximum operating temperature 60°C.
Range of shower handsets plastic bodies (various finishes) and EPDM ‘O’-rings. All models include a button on the shower face which alters the spray pattern. The product incorporates either a plastic strainer (26 050 & 26 530) or a stainless-steel strainer and a plastic flow regulator (26 051 & 26 531) on the inlet. Maximum operating temperature 60°C.
Shower bracket, incorporating a brass body(various finishes) and EPDM O’-rings. Maximum operating temperature 85°C.
Range of shower handsets incorporating plastic bodies (various finishes). The inlet incorporates an approved single check valve cartridge, however the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum operating temperature 60°C.
Range of shower outlets: swivel ball joint overhead shower heads with brass bodies (chromium plated) and shower handsets with plastic bodies (chromium plated). The overhead showers incorporate a combined EPDM washer and stainless-steel strainer on the inlet. Maximum operating temperature 65°C.
Range of ceiling mounted shower outlets. The inlet to the shower head incorporates a combined NBR gasket and stainless steel filter, as well as a plastic flow regulator which is located after an adjustable ball joint. Maximum operating temperature 60°C.
Shower handset with chrome plated bodies and built in flow restrictors. Maximum operating temperature 60°C.
Shower handset with plastic bodies (chrome plated). Maximum operating temperature 65°C.
Swivel ball joint overhead shower head with brass bodies (chrome plated). The overhead showers incorporate a combined EPDM washer and stainless-steel strainer on the inlet. Maximum operating temperature 65°C.
Range of flow switches with plastic bodies. The VK308/10/15/20/25/32/40/50M and VKS08/10/15/20/25/32/40/50M prefix models are supplied with an inline brass adaptor. The VK305/306/309M and VKS05/06/09M prefix models are supplied with a brass adaptor for direct insertion into a pipe. Maximum working pressure 10.0 bar. Maximum operating temperature 100°C.
Range of bib taps incorporating either brass or DZR brass bodies. The inlet and the outlet of the tap incorporates approved single check valve cartridges however, the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum working pressure 16.0 bar. Maximum operating temperature 85°C.
Range of pillar taps incorporating either stainless steel or brass bodies (various finishes), quarter turn ceramic disc headworks with a single lever operating member. The spout outlet incorporates a plastic aerator. The RB3 models are supplied with a pop-up waste. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.
Range of self-closing combination taps with brass bodies (chrome plated), incorporating a non-concussive headwork with dome type operating members. The inlets incorporate an approved single check valve cartridge, however the complete assembly has not been verified to demonstrate it provides backflow protection. The inlets of model 28681 incorporate a stainless-steel filter. The inlets of model 28682 incorporate a servicing valve and stainless-steel filter. The outlets of all models incorporate a plastic flow straightener. Maximum working pressure 8.0 bar. Maximum operating temperature 60°C.
‘OH RPE’ Range of PE-RT (multi-layer) flexible hoses (white inner/silver outer). The following end connections are available with one or two approved single check valve cartridge(s), however, the complete product has not been fully tested to demonstrate it provides backflow protection: CQC (one) and SQC (one or two). Maximum operating temperature 65°C.
OH Softpex® range of polyethylene lined outlet hoses with stainless steel and polyamide braiding (length 100 to 1000 mm), with various end connections. The hose incorporates an approved check valve cartridge, however, the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum operating temperature 65°C.
Range of indirect and direct unvented storage cylinders consisting of either no coil (GLE) or a factory fitted single (GLC) or twin coil (GLT). The secondary circuit is supplied with a temperature and pressure relief valve set at 7.0 bar@85˚C for 1.0-6.0 bar products and 10.5 bar@95°C for 6.0-10.0 bar products. The products are supplied with an inlet control group (safety kit) consisting of a pressure reducing valve, an expansion relief valve 6.0 bar (1.0-6.0 bar products) or 10.5 bar (6.0-10.0 bar products) and an approved check valve, however, the complete product has not been fully tested to demonstrate it provides backflow protection. Product is also supplied with an expansion vessel. Maximum working pressure 10.0 bar. Maximum operating temperature 85°C
Range of free standing direct gas fired unvented cyliners with a enamel coating internal lining and magnesium sacrificial anode. Fitted with a combined temperature and pressure relief valve set at 7 bar. Maximum working pressure 6.5 bar. Maximum operating temperature 80°C.
Range of two, three, four and five-way manifold assemblies incorporating brass bodies (brushed chrome finish) and EPDM ‘O’-rings. The products are supplied with isolation valves. Maximum working pressure 10.0 bar. Maximum operating temperature 95°C.
Wall mounted, exposed thermostatic shower valve (chromium plated brass) incorporating a thermostatic cartridge that controls the temperature and a shut off valve that controls the flow both with a single lever operating member. The inlets incorporate stainless steel strainers and an approved check valve cartridge, however, the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum working pressure 8.0 bar. Maximum operating temperature 60°C.
Wall mounted, bar type, thermostatic shower blending valves (chromium plated brass), incorporating a quarter turn ceramic disc headwork controlling the flow with a dome type operating member. The temperature is controlled independently via a thermostatic cartridge with a dome type operating member incorporating a manual override button. Both inlets incorporate a stainless-steel strainer and an approved check valve cartridge, however the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum working pressure 10.0 bar. Maximum operating temperature 65°C.
Wall mounted bar type thermostatic shower valve, with a ceramic cartridge headwork controlling the flow between overhead shower and handset with a dome type operating member incorporating a manual override button. The temperature is controlled independently via a thermostatic cartridge with a dome type operating member incorporating a manual override button. Both inlets incorporate a strainer and a single check valve cartridge, however, the complete assembly has not been tested to demonstrate it provides backflow protection. Supplied with hose and handset. Maximum working pressure 10.0 bar. Maximum operating temperature 65°C.
Concealed, thermostatic shower blending valve, incorporating a brass body and a (chrome plated) functional trim set. The functional trim set comprises of two detent headworks (push to on, push to off) as the main flow control for each shower outlet, a ¼ turn ceramic disc valve with a dome type operating member controlling the flow volume, and a thermostatic cartridge controlling the temperature with a dome type operating member incorporating a manual override button. The functional trim set is also supplied with two brass assemblies comprising of a plastic filter, EPDM ‘O’-rings and an approved check valve cartridge, however the complete assembly has not been tested to demonstrate it provides adequate backflow protection. These assemblies are to be inserted into the concealed body. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.
Range of concealed, thermostatic shower blending valves, incorporating a brass body and a (chrome plated) functional trim set. The functional trim set comprises of a quarter turn ceramic disc headwork, or a 2 or 3 way ceramic disc diverter headwork (see model) with a dome type operating member controlling the flow, and a thermostatic cartridge controlling the temperature with a dome type operating member incorporating a manual override button. The functional trim set is also supplied with two brass assemblies comprising of a plastic filter, EPDM ‘O’-rings and an approved check valve cartridge, however the complete assembly has not been tested to demonstrate it provides adequate backflow protection. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.
Concealed, thermostatic shower blending valve, incorporating a brass body and a (chrome plated) functional trim set. The functional trim set comprises of a 2 way ceramic disc diverter headwork with a dome type operating member controlling the flow, and a thermostatic cartridge controlling the temperature with a dome type operating member incorporating a manual override button. The functional trim set is also supplied with two brass assemblies comprising of a plastic filter, EPDM ‘O’-rings and an approved check valve cartridge, however the complete assembly has not been tested to demonstrate it provides adequate backflow protection. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.
Range of wall mounted thermostatic shower panels. Model TFP3001 incorporates a single sequential headwork which controls the flow and temperature using a single lever operating member with an addtional self-closing headwork with dome type operating member which also controls the flow to a fixed shower head. Model TFP3002 incorporates a single sequential headwork which controls the flow and temperature using a single lever operating member to a fixed riser rail shower hose and handset. Model TFP3003 incorporates a self-closing headwork which controls the flow using a dome type operating member to a fixed shower outlet, temperature is pre-set using a thermostatic valve. The inlets on all models incorporate single check valve cartridges, however, the complete product has not been fully tested to demonstrate it provides backflow protection. Supplied with stainless steel strainers, flow restrictors and isolation valves. Maximum working pressure 10.0 Bar. Maximum operating temperature 60°C.
Range of wall mounted, concealed, thermostatic shower blending valves with brass bodies and trim sets (chrome plated). Incorporating a thermostatic cartridge headwork with cubed or dome type operating members. The inlets incorporate a flow regulator and an approved check valve cartridge; however, the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.
Range of wafer and lugged type butterfly valves incorporating blue epoxy coated cast iron bodies, stainless steel discs and EPDM seat. The closing mechanism can be controlled by either a lever, gear or bore shaft. Maximum working pressure 16.0 bar. Maximum operating temperature 85°C.
Range of double flanged and wafer type butterfly valves with cream epoxy coated cast iron bodies, EPDM seats and a range of discs (see models). Maximum working pressure 16.0 bar. Maximum operating temperature 60°C.
Range of wafer and lugged type butterfly valves incorporating blue epoxy coated cast iron bodies, stainless steel discs and EPDM seat. The closing mechanism can be controlled by either a lever, gear or bore shaft. Maximum working pressure 16.0 bar. Maximum operating temperature 85°C.
Range of combined temperature and pressure relief valves incorporating DZR brass bodies, EPDM ‘O’-rings and silicone seat washers. The vales are pre-set at 4.0, 6.0, 7.0 or 10.0 bar (see model). The valves incorporate a manually operated rotational easing gear. Maximum operating pressure 10.0 bar. Maximum operating temperature 90°C.
Range of piston type float operated inlet valves with brass bodies. The valves discharge from a downwards atmospheric discharge arrangement on the underside of the body. Maximum working pressure: 3.0 (1FVA106 & 1FVA104 models only) or 14.0 Bar (all other models) Cold water use only.
Piston type float operated inlet valves with blue epoxy coated ductile iron bodies. The products are supplied with a plastic float and carbon steel (galvanised) lever. The valves discharges from a downwards atmospheric discharge arrangement on the underside of the body. Maximum working pressure 16.0 bar. Cold water use only.
Range of ‘Keraflo Aylesbury’ ceramic disc operated inlet valves with DZR brass bodies and ABS or copper outlets. K and KAX type float mechanism incorporate a polyethylene float and spirit level for installation. The KB type float mechanism is operated by a transfer of weight within the actuator tube, which is connected to a polyethylene buoy and weight via stainless steel chain. Maximum working pressure 10.0 bar. Cold water use only.
Deck mounted flow control valve incorporating a brass body, quarter turn ceramic disc headwork with circular operating members and EDPM ‘O’-rings. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.
Range of adjustable pressure reducing (pilot) valves with stainless steel bodies, EPDM diaphragm and ‘O’-ring. Outlet pressures are adjustable between 1.0 to 5.0 bar (ACV100C model), 1.5 to 10.0 bar (ACV100E model) and 2.0 to 15.0 bar (ACV100F model). Maximum supply pressure 16.0 bar. Cold water use only.
Range of pilot operated pressure reducing control valves with ductile iron bodies (blue polyester or epoxy coating) and EPDM diaphragm. Maximum inlet pressure 25.0 bar. Outlet pressure setting is adjustable in the range of 1.0 – 16.0 bar. Maximum operating temperature 65°C.
Range of pre-set pressure relief valves with bronze bodies and EPDM seating discs. Available with either a manual lever or dome type sealed cap. Pre-set relief pressures: DN15 and DN40 valves: 0.35 bar to 15.9 bar. DN20 valves: 0.35bar to 13.8bar. DN25, DN32 and DN50 valves: 0.35 bar to 12.5 bar. Maximum operating temperature 85°C.
Isolation elbow, incorporating brass bodies (chrome plated) and brass ball (chrome plated), EPDM O-rings and a PTFE seal. The product is supplied with plastic backnuts. Maximum working pressure 5.0 bar. Maximum operating temperature 50°C
Angled valve (chromium plated brass body), NBR rubber seals and a dome type operating member. Maximum working pressure 10.0 bar. Maximum operating temperature 100°C
Range of in-line, “T” type or angled spherical valves incorporating brass bodies and brass ball, EPDM ‘O’-rings/Washers, PTFE seats and single lever or butterfly lever operating members. Some models incorporate port or pressure gauge. Models 0516/03DCVR1, 0516/03DCVR2 & 0516/04TR1 incorporate approved check valve cartridges, verified by test (suitable for backflow protection against Fluid Category 3). Maximum working pressures 10.0 bar Maximum operating temperature 100°C.
Range of brass bodied, straight and angled two and three-port spherical valves. Some models incorporate a screw-down pattern drain valve. Products incorporate a chrome-plated brass ball and EPDM ‘O’-rings. Maximum working pressure 16.0 bar. Maximum operating temperature 85°C.
Range of spherical valves (nickel plated) brass bodies with single lever operating members, (chromium plated) brass ball and PTFE seat. Maximum working pressure 40.0 bar (Models 124-1027 CST, 124-1028 CST and 124-1029 CST) Maximum working pressure 25.0 bar (Models 124-1030 CST and 124-1031 CST) Maximum working pressure 16.0 bar (Models 124-1032 CST and 124-1033 CST) Maximum operating temperature 85°C.
Range of angled isolation ball valves incorporating brushed chrome plated DZR brass bodies, DZR brass ball (chrome plated), stainless steel strainer and approved check valve cartridge, however, the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum working pressure 10.0 bar. Maximum operating temperature 85°C.
Range of pressfit connection spherical valves incorporating DZR brass bodies, PTFE seat and packing, NBR ‘O’-rings and various operating members: lever, lever lockable, T-handle and butterfly. For use with copper pipe (manufactured to BS EN 1057), stainless steel pipe (manufactured to BS EN 10312) and carbon steel pipe (ISO 4200 Groupe 1 Series 3). Maximum working pressure 16.0 bar. Maximum operating temperature 99°C.
Range of automatic thermal balancing valves (DZR Brass) with non-rising spindle headwork, brass disc and EPDM seals. Maximum working pressure 16.0 bar. Maximum operating temperature 100°C.
Range of thermostatic circulation valves incorporating brass bodies and EDPM ‘O’-rings. Some models incorporate a gauge port. Maximum working pressure 16.0 bar. Maximum operating temperature 65°C.
Range of double regulating valves incorporating bronze bodies, brass disc face (½” - ¾” models) or PTFE (1” - 2” models), PTFE plate and NBR ‘O’-rings. Maximum working pressure 25.0 bar. Maximum operating temperature 100°C.
Silver and copper disinfection ion generator with a plastic body, incorporating a plastic flow switch. Maximum working pressure 9.0 bar. For cold water use only
Range of ion exchange water softeners (salt regenerated) for domestic use. Maximum working pressure 6.0 bar. Cold water use only.
‘Inertol BS10’. Factory applied, black coloured bitumen coating. Apply as per manufacturer’s technical data sheet 'no. 786.3' dated 2013-V2'. Cure for 5 hours@23°C or 30 minutes@50°C. For use with water up to 60°C. This material is only approved for the curing conditions that appear on the approval. If the cure conditions are varied from those specified on the approval then the material is not covered by the scope of the approval. Petroleum or asphaltic bitumen, NOT coal tar bitumen. Materials listed in this section are not approved for use for contact with water that is required to be wholesome on large water retaining structures such as lining of pipes, cisterns or water storage tanks.
'GMF-01'. Factory applied, grey coloured cement mortar. Mix sand, water & cement in a 1.5:1.0:1.0 weight ratio. Cure for 24 hours@25°C. For use with water up to 65°C. This material is only approved for the mixing and curing conditions that appear on the approval. If the mix and/or cure conditions are varied from those specified on the approval then the material is not covered by the scope of the approval.
'EARTHSTAHL TYPE OPC'. Factory applied, grey coloured cement mortar. Mix cement, sand & water in a 1.0:1.5:0.5. Cure for 28 days@26°C. For use with water up to 50°C. This material is only approved for the mixing and curing conditions that appear on the approval. If the mixing and/or curing conditions are varied from those specified on the approval then the material is not covered by the scope of the approval.
'EARTHSTAHL TYPE SRC'. Factory applied, grey coloured cement mortar. Mix cement, sand & water in a 1.0:1.5:0.5. Cure for 28 days@26°C. For use with water up to 50°C. This material is only approved for the mixing and curing conditions that appear on the approval. If the mixing and/or curing conditions are varied from those specified on the approval then the material is not covered by the scope of the approval.
'EARTHSTAHL TYPE BFSC'. Factory applied, grey coloured cement mortar. Mix cement, sand & water in a 1.0:1.5:0.5. Cure for 28 days@26°C. For use with water up to 50°C. This material is only approved for the mixing and curing conditions that appear on the approval. If the mixing and/or curing conditions are varied from those specified on the approval then the material is not covered by the scope of the approval.
'Tankguard 412'. White coloured, factory applied, 2 part epoxy coating. Mix and apply as per manufacturer's TDS dated 6 November 2015. Cure for 7 days@23°C. Between 1st November 2021 and 27th July 2022 this coating is for use with water up to 23°C. Between 28th July 2022 and 30th November 2026 this coating is for use with water up to 60°C. This material is only approved for the curing conditions that appear on the approval. If the cure conditions are varied from those specified on the approval then the material is not covered by the scope of the approval.
'Powercron® 6070'. Factory applied, black coloured, electrodeposition coating. Apply and cure as per technical data sheet ‘LT/F-16-128’ dated October 20th 2016. For use with water up to 23°C.
'Flogul® 645 Vert 6013'. Factory applied, green coloured paint. Apply as per manufacturer's data sheet dated '11/09/2018'. Cure for 7 days@20°C. For use with water up to 23°C. This material is only approved for the curing conditions that appear on the approval. If the cure conditions are varied from those specified on the approval then the material is not covered by the scope of the approval.
'JSAW-JAL (Cement-SDC)'. Factory applied, grey coloured, Sulphate Resisting Portland Cement mortar. Mix cement, sand and water in a 1:1.5:0.5 weight ratio. Cure for 2 hours and 30 minutes@45°C and 85 relative humidity. Then cure again for 3 days@30°C and 80% relative humidity. For use with water up to 65°C. This material is only approved for the mixing and curing conditions that appear on the approval. If the mix and cure conditions are varied from those specified on the approval then the material is not covered by the scope of the approval.
'JSAW-JAL (Cement-SIL)'. Factory applied, grey coloured Ordinary Portland Cement mortar. Mix cement, sand and water in a 1:1.5:0.5 weight ratio. Cure for 2 hours and 30 minutes@45°C and 85 relative humidity. Then cure again for 3 days@30°C and 80% relative humidity. For use with water up to 65°C. This material is only approved for the mixing and curing conditions that appear on the approval. If the mix and cure conditions are varied from those specified on the approval then the material is not covered by the scope of the approval.
'JSAW-JAL (Cement-JSL)'. Factory applied, grey coloured Blast Furnace Slag Cement mortar. Mix cement, sand and water in a 1:1.5:0.5 weight ratio. Cure for 2 hours and 30 minutes@45°C and 85 relative humidity. Then cure again for 3 days@30°C and 80% relative humidity. For use with water up to 65°C. This material is only approved for the mixing and curing conditions that appear on the approval. If the mix and cure conditions are varied from those specified on the approval then the material is not covered by the scope of the approval.
`Vulkanite Bio`. Red coloured, compressed fibre gasket material. For use with water up to 65°C. For use only as a jointing/gasket material having been tested at a reduced surface area to volume ratio.
‘Fybar PT 60' (light green on one side and beige on the other). Fibre/NBR gasket material manufactured by calendaring. For use with water up to 85°C. For use only as a jointing/gasket material having been tested at a reduced surface area to volume ratio.
'Ultramid® B3EG7 black 00564' (Black coloured) & 'Ultramid® B3EG7 uncolored' (appears beige). Injection moulded nylon materials. 'Ultramid® B3EG7 uncolored' is for use with water up to 65°C. 'Ultramid® B3EG7 black 00564' is for use with water up to 85°C.
'EcoPaXX® Q-DWX6 BK00002 & EcoPaXX® Q-DWX10 BK00002’ (black coloured). 'EcoPaXX® Q-DWX6 NA99001 & EcoPaXX® Q-DWX10 NA99001’ (natural – appears beige). Injection moulded polyamide materials. For use with water up to 85°C.
'Green Pipes HDPE Pipes'. Black coloured (with blue external stripe), extruded HDPE pipe. For use with water up to 65°C.
'Green Pipes HDPE Fittings'. Black coloured (with blue external stripe), fabricated butt-fusion HDPE fittings. For use with water up to 65°C.
'XD PE Fitting'. Black coloured, injection moulded polyethylene fitting. For use with water up to 60°C.
'iJoint'. Black coloured, injection moulded polypropylene fitting. For use with water up to 60°C.
'Eurocarboran TIPO A Naturale (132.166.120)'. Natural (appears off-white), injection moulded PP material. For use with water up to 85°C.
'EP10/00/2 BLK EPDM 'O' rings'. Black coloured, injection moulded EPDM 'O' rings. Shore hardness 65. Tested in-radius size 1.5mm. For use with water up to 85°C.
`TL-KN-006`. Black coloured, compression moulded EPDM rubber material. Shore hardness 75. Tested in-radius size 1.1mm. For use with water up to 23°C.
Black coloured, compression moulded EPDM components. For use with water up to 85°C. ‘559843, 55985 & 559865’ ‘O’ rings. Shore hardness between 60 & 80. Tested in-radius sizes between 1.31mm & 3.49mm. ‘55985 Gasket’. Shore hardness 70. Tested in-radius size 1.0mm. ‘559865 gasket’. Shore hardness 80. Tested in-radius size 1.50mm. When processing an application for a Product Approval incorporating these components, these are the only shapes of components that are covered by the scope of the approval’.
'Sunaflex T 8157'. Black coloured, compression moulded EPDM rubber material. Shore hardness 60. Tested in-radius size 1.0mm. For use with water up to 23°C.
'EP50, EP55, EP60, EP65, EP70, EP75 & EP80'. Black coloured, transfer moulded EPDM material. Shore hardness between 50 & 80. Tested in-radius size 1.1mm. For use with water up to 85°C.
'006800.3 washer, 006802.6 washer & 006906.4 slab (made using 7741 compound)'. Red coloured, compression moulded VMQ components. Shore hardness 70. The '006800.3 washer’ has a tested in-radius size of 1.16mm. The ‘006802.6 washer’ has a tested in-radius size of 1.15mm. The ‘006906.4 slab' has a tested in-radius size of 1.17mm. For use with water up 85°C.
'TPE-GB6061G (grey coloured) & TPE-GB6061B (blue coloured)'. Injection moulded TPE materials with a shore hardness of 60. TPE-GB6061G has a tested in-radius size of 1.41mm. TPE-GB6061B has a tested in-radius size of 1.38mm. For use with water up to 75°C.
Floor mounted single hole, single outlet (fixed) combination tap assemblies with brass bodies (various finishes - see model). The product incorporates a ceramic cartridge headwork with a single lever operating member and a lockable diverter to shower outlet. The spout outlet incorporates a plastic aerator. The products are supplied with a shower hose and handset. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.
Range of deck mounted, single hole, single outlet (fixed) electronically controlled tap assemblies (brass body - various finishes, see model). Flow is controlled by a solenoid valve activated via an infra-red sensor. The spout outlet incorporates a plastic aerator. The inlet hose incorporates an approved single check valve cartridge, however, the complete assembly has not been tested to demonstrate it provides backflow protection. Maximum working pressure 8.0 bar. Maximum operating temperature 60°C.
Range of deck mounted, single hole, single outlet (fixed) electronically controlled tap assemblies (brass body - various finishes, see model). Flow is controlled by a solenoid valve activated via an infra-red sensor. The product incorporates a manual temperature control operated by a single lever on the side of the body. The spout outlet incorporates a plastic aerator. The inlet hoses incorporate an approved single check valve cartridge, however, the complete assembly has not been tested to demonstrate it provides backflow protection. Maximum working pressure 8.0 bar. Maximum operating temperature 60°C.
A range of wall mounted two hole single outlet (fixed) electronically controlled tap assemblies with brass bodies (various finishes). Flow is controlled by a solenoid valve activated by via an infra-red sensor on the underside of the tap. The inlets of the function block incorporate stainless steel strainers, plastic silencers and approved check valve cartridges, however, the complete product has not been fully tested to demonstrate it provides backflow protection. The spout outlet incorporates a plastic aerator. Maximum working pressure 10.0 bar. Maximum working temperature 60°C.
Range of wall mounted, single hole, single outlet (fixed) electronically controlled tap assemblies comprising of a concealed brass body and a separate spout and trim set (chromium plated brass). Flow is controlled by a solenoid valve activated via an infra-red sensor. The inlets (within the) concealed body incorporate a plastic filter and an approved check valve cartridge, however, the complete product has not been fully tested to demonstrate it provides backflow protection. The spout outlet incorporates a plastic aerator. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.
Wall mounted, single hole, single outlet (fixed) electronically controlled tap assembly (various finishes). The flow is controlled by a solenoid valve activated via an infra-red sensor. The spout outlet incorporates a plastic aerator. Maximum working pressure 6.0 bar. Maximum operating temperature 40°C.
Deck mounted, single hole, single outlet (fixed) electronically controlled tap assembly (various finishes). The flow is controlled by a solenoid valve activated via an infra-red sensor. The spout outlet incorporates a plastic aerator. Product supplied with metal backnuts. Maximum working pressure 6.0 bar. Maximum operating temperature 40°C.
Deck mounted, single hole, single outlet (fixed) electronically controlled tap assembly (various finishes). The flow is controlled by a solenoid valve activated via an infra-red sensor. The spout outlet incorporates a plastic aerator. Product supplied with metal backnuts. Maximum working pressure 6.0 bar. Maximum operating temperature 40°C.
Wall mounted, single hole, single outlet (fixed) electronically controlled tap assembly (various finishes). The flow is controlled by a solenoid valve activated via an infra-red sensor. The spout outlet incorporates a plastic aerator. Maximum working pressure 6.0 bar. Maximum operating temperature 40°C.
Range of BS1212-4 (2016) compact type float operated valves for WC flushing cisterns, bottom or side entry type. The inlet incorporates a strainer. Maximum working pressure 10.0 bar. Cold water use only.
Side entry BS1212-4 (2016) compact type float operated valves for WC flushing cisterns. The inlet incorporates a plastic strainer and flow restrictor. Maximum working pressure 10.0 bar. Cold water use only.
Range of concealed WC flushing cisterns with a side entry BS 1212-4(2016) float operated inlet valve providing a type AG air gap arrangement and a dual flush outlet valve. The flush volume is operated by a two button assembly for a 6 or 3 litre flush volume. The cistern incorporates a servicing valve and a stainless-steel braided EPDM lined flexible hose assembly installed prior to the inlet valve. Maximum working pressure 10.0 Bar, Cold Water use only
Range of concealed WC flushing cisterns incorporating a side entry compact type float operated inlet valve providing a Type AG air gap with a dual flush drop valve for full flush volumes of up to 6 litres and a reduced flush of up to 4 litres. The cistern is operated by a manual push button and incorporates a servicing valve and flexible hose on the inlet supply. Maximum working pressure 10.0 bar. Cold water use only. .
Concealed WC dual flushing cistern with a BS 1212-4 (2016) float operated inlet valve providing a Type AG air gap arrangement and a dual flush pneumatic outlet valve. The flush volume is operated by a two-push button assembly for a 6 or 3 litre flush volume and incorporates a servicing valve and flexible hose on the inlet supply. Maximum working pressure 10.0 bar. Cold water use only.
Range of single check valve assemblies incorporating DZR brass bodies. Maximum working pressure 10 bar. Maximum operating temperature 85°C.
Range of single check valve assemblies incorporating DZR brass bodies. Maximum working pressure 10 bar. Maximum operating temperature 85°C.
Double check valve assembly consisting of two spring loaded resilient trim in-line check valve cartridges housed in a DZR brass body (chrome plated) with a port located between the cartridges. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C
A range of ceramic cartridge headworks with plastic bodies incorporating EPDM `O`-rings and seals for insertion into specifically dimensioned bodies. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.
Range of ceramic cartridge headworks with plastic bodies and silicone gaskets. The products are intended for insertion into specifically dimensioned tap bodies. Maximum working pressure 16.0 bar. Maximum operating temperature 85°C.
Range of ceramic disc headworks with brass bodies to be inserted into specifically dimensioned bodies. Maximum working pressure 16.0 bar. Maximum operating temperature 85°C
A range of single hole, single outlet (swivel) combination tap assemblies with brass bodies (chrome plated), incorporating a ceramic cartridge headwork (models 63465-0001) or a quarter turn ceramic disc headwork (model 63461-0001) with single lever operating members. The products incorporate a pull-out spray with a plastic aerator at the outlet. The pull-out spray hose for model 63465-0001 incorporates an approved check valve cartridge, however, the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum working pressure 5.0 bar. Maximum working temperature 60°C.
Single hole, single outlet (swivel) combination tap assembly (chrome plated brass) incorporating quarter turn ceramic disc headworks with single lever operating members and pull out spray handset. The outlet hose incorporates an approved check valve cartridge, however, the complete product has not been fully tested to demonstrate it provides backflow protection The spout outlet incorporates a plastic aerator. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.
Single hole, single outlet (swivel) combination tap assembly with brass bodies (chrome plated), incorporating a ceramic cartridge headwork with single lever operating members. The product incorporates a pull-out spray with a plastic aerator at the outlet. The pull-out spray hose incorporates an approved check valve cartridge, however, the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum working pressure 5.0 bar. Maximum working temperature 60°C.
Range of single hole, single outlet (swivel) pull down spray combination tap assemblies (brass bodies - various finishes - see model), incorporating a ceramic cartridge headwork with a single lever operating member. The connection between the body and the spout incorporates an approved check valve cartridge, however the complete product has not been fully tested to demonstrate it provides backflow protection. The outlet incorporates a plastic aerator. The products are supplied with optional ½” BSP (F) x ⅜ BSP (M) brass adaptors and NBR washers for installation on each inlet hose. Maximum working pressure 6.0 bar. Maximum operating temperature 60°C.
Wall mounted single-hole, single outlet, fixed, combination tap assembly with a brass body in a variety of finishes (See models). Incorporating a ceramic disc headwork with a dome type operating member. The temperature is controlled separately via a rotary ceramic cartridge headwork that can also be used as a shut off with a dome type operating member. The inlets to the tap incorporate an approved check valve cartridge; however, the complete product has not been fully tested to demonstrate it provides backflow protection. The spout outlet incorporates a plastic aerator and plastic flow regulator. Maximum working pressure 10 bar. Maximum working temperature 60°C.
Range of single hole, single outlet (fixed) combination tap assemblies incorporating brass bodies (various finishes), ceramic cartridge headworks with single lever operating members. The spout outlets incorporates a plastic aerator. Models 100121306, 100121305 & 100123629 are supplied with lever operated pop-up waste. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.
Range of single hole, single outlet (fixed) combination tap assembly (chromium plated brass). Incorporating ceramic cartridge headworks, and single lever operating members. The spout outlet incorporates a plastic aerator. Model 65001 and 65004 supplied with a pop up waste. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.
Range of single-hole, single outlet (fixed) combination tap assemblies (chromium plated brass) incorporating a ceramic cartridge headworks with a single lever operating members. The spout outlets incorporate a plastic aerator. Model A42326VUK is supplied with a lever operated pop-up waste. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.
Range of single hole, single outlet (fixed) combination tap assemblies with brass bodies (chrome plated), incorporating a ceramic cartridge headwork and single lever operating members. The spout outlet incorporates a plastic aerator. Model A42325VUK X-LINE is supplied with a pop-up waste. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.
Range of single hole, single outlet (fixed) combination tap assemblies (chromium plated brass), incorporating a ceramic cartridge headwork with a single lever operating member. The spout outlet incorporates a plastic aerator. The BC428AA and BC430AA models are supplied with a pop-up waste. The products are supplied with loose ⅜” BSP (M) x 15mm compression adaptors for installation on each inlet. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.
Range of single hole, single outlet (fixed) combination tap assemblies (chrome plated brass). Incorporating a ceramic cartridge headwork and single lever operating members however model TPNORMONO2 is fitted with a non rising spindle headwork and dome type operating members. The spout outlet incorporates a plastic flow straightener on models: TPSOUMONO2, TPNORMONO2, TPASHMINI2 & TPASHMONO2. Maximum working pressure 6.0 bar. Maximum operating temperature 60°C.
Range of single hole, single outlet (fixed) combination tap assemblies incorporating brass bodies (chrome plated) ceramic cartridge headwork and single lever operating member. The spout outlet incorporates a plastic aerator. Maximum working pressure 10.0 Bar. Maximum operating temperature 60°C.
Range of single hole, single outlet, fixed combination tap assemblies (brass bodies, various finishes - see model), incorporating a ceramic cartridge headwork with a single lever operating member. The spout outlet incorporates a plastic aerator or flow straightener (63446-7001 and 63455-7001 models only). The 63446-7001 model also incorporates a combined EPDM washer and stainless steel strainer on the spout outlet. The inlet hoses incorporate a combiner washer and stainless-steel strainer. The products are supplied with click type pop-up waste. Maximum working pressure 5.0 bar. Maximum working pressure 60°C.
Range of single hole, metal, single outlet (swivel) combination tap assemblies (chromium plated brass), incorporating a ceramic cartridge headwork with a single lever operating member. The spout outlets incorporate plastic aerators. The 31 609 xxx model is supplied with a pop-up waste. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.
Single hole, single outlet (swivel) combination tap assembly (stainless steel body), incorporating quarter turn ceramic disk headworks. The spout outlet incorporates a plastic aerator Maximum working pressure 5.5 bar. Maximum operating temperature 60°C.
Range of single hole, single outlet (swivel) combination tap assemblies with brass bodies (various finishes, see model), incorporating a ceramic cartridge headwork with a single lever operating member. The spout outlet incorporates a plastic flow straightener. Supplied with single check valves that incorporates a servicing valve. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.
Range of single hole, single outlet (swivel) combination tap assemblies (chromium plated brass), incorporating ceramic cartridge headwork with single lever operating members controls the flow of hot and cold water. A quarter turn ceramic disc headwork with single lever operating member which incorporates a manual override button, controls the flow of near-boiling water (unit not supplied). The spout outlets incorporate a plastic flow straightener. Maximum working pressure: hot and cold water = 5.0 bar, near-boiling supply = 3.0 bar. Maximum operating temperature hot and cold water circuit is 65°C. Maximum operating temperature of near-boiling water circuit 99°C
A single-hole, single outlet, (swivel) combination tap assembly with a brass body (chrome plated), incorporating a ceramic cartridge headworks with single lever operating member and a separate quarter turn ceramic disc headwork for filtered cold water. The quick connector and the brass connector incorporate approved check valve cartridges, verified by test (suitable for back flow protection against Fluid Category 2). The spout outlet incorporates a plastic aerator. Maximum working pressure 5.0 bar. Maximum working temperature 60°C.
Range of single hole, single outlet (swivel) combination tap assemblies (chromium plated brass). Incorporating ceramic disc headworks with single lever operating members. The spout outlets incorporate a plastic aerator. The cold inlet hose incorporates an approved check valve cartridge, however, the complete product has not been fully tested to demonstrate it provides backflow protection Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.
Range of single hole, single outlet (swivel) combination tap assemblies (chromium plated brass), incorporating a ceramic disc headworks with a single lever operating members. The spout outlet incorporates a plastic aerator. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.
Single hole, single outlet (swivel), combination tap assembly (chromium plated brass), incorporating a ceramic cartridge headwork with a single lever operating member. The spout incorporates a push to open, push to close ‘detent’ headwork and the spout outlet incorporates a plastic aerator. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.
Range of single hole, single outlet (swivel) combination tap assemblies (chromium plated brass). Incorporating ceramic disc headworks with single lever operating members. The spout outlets incorporate a plastic aerator. The cold inlet hose incorporates an approved check valve cartridge, however, the complete product has not been fully tested to demonstrate it provides backflow protection Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.
Range of single hole, single outlet (swivel) combination tap assemblies (chromium plated brass), incorporating a ceramic disc headworks with a single lever operating members. The spout outlet incorporates a plastic flow straightener or aerator. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.
Range of single hole, single outlet (swivel) combination tap assemblies (chromium plated brass). Incorporating ceramic cartridge headworks and single lever operating members. The spout outlet incorporates a plastic aerator. Maximum working pressure 6.0 bar. Maximum operating temperature 60°C.
Range of single hole, single outlet (swivel) combination tap assemblies (chromium plated brass), incorporating a ceramic cartridge headwork with a single lever operating member. The spout outlet incorporates a plastic aerator. The 33500626 and 33515626 models are supplied with a pop-up waste. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.
Range of single hole, single outlet (swivel) combination tap assemblies (chromium plated brass), incorporating a ceramic cartridge headwork with a single lever operating member. The spout outlet incorporates a plastic aerator. The inlet hoses incorporate a combiner washer and stainless-steel strainer. Maximum working pressure 5.0 bar. Maximum working pressure 60°C.
Wall mounted, two-hole, single outlet (fixed) combination tap assembly (chromium plated brass) incorporating a ceramic cartridge headwork with a single lever operating member. The spout outlet incorporates a plastic aerator. To be used with rough set 13622180. Maximum working pressure 10.0 Bar. Maximum operating temperature 60°C.
Wall mounted, two-hole, single outlet (fixed) combination tap assembly with brass body (chrome plated), incorporating single sequential headwork with single lever operating member. The inlets incorporate a screwdriver operated servicing valve and an approved check valve cartridge, however, the complete product has not been fully tested to demonstrate it provides backflow protection Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.
Deck mounted, two-hole, single outlet (fixed) concealed combination tap assembly with brass body (chrome plated), incorporating a single sequential headwork with single lever operating member. The inlets incorporate a screwdriver operated servicing valve and an approved check valve cartridge, however, the complete product has not been fully tested to demonstrate it provides backflow protection Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.
Range of concealed two hole, single outlet (fixed) wall mounted tap assemblies, with a brass bodies and chrome plated trim set. Consisting of a rough in set 63397 and external trim 65088 and 65089. Incorproating a ceramic cartridge headworks and single lever operating members.The spout outlet incorporates a plastic aerator. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.
Range of wall mounted, two hole, single outlet (fixed) combination tap assemblies (chromium plated brass or stainless steel), comprising of a concealed rough in set with a brass body and a variety of separate trim sets incorporating a ceramic cartridge headwork with a dome type or single lever operating member and a spout outlet. The spout outlet incorporates a plastic aerator. The products are supplied with click type (click clack) waste. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.
Range of two hole, single outlet (fixed) combination tap assemblies (chrome plated brass). Incorporating quarter turn ceramic disc headworks and single lever operating members. The spout outlets incorporate either a plastic flow straightener or aerator depending on model. Maximum working pressure 6.0 bar. Maximum operating temperature 60°C.
Range of wall mounted, two-hole, single outlet (fixed) combination tap assemblies with (brass bodies, various finishes - see model), incorporating a ceramic cartridge headwork with a single lever operating member. The spout outlets incorporate a plastic aerator. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.
Range of two-hole, single outlet, fixed combination tap assemblies (chrome plated brass), incorporating a single sequential cartridge headwork with a dome type operating member. The spout outlet is connected to the flow control valve via a stainless steel braided PEX lined flexible hose assembly. The spout inlet incorporates a plastic flow regulator, and the spout outlet incorporates a plastic aerator. Maximum working pressure 10.0 bar. Maximum working temperature 60°C.
Range of wall mounted two hole, metal, single outlet (fixed) combination tap assemblies (chromium plated brass), incorporating a 2 way ceramic disc diverter controlling the flow between the spout outlet and the shower outlets with a dome type operating member. Temperature is controlled independently via a thermostatic cartridge with a dome type operating member which incorporates a manual override button. The product incorporates a secondary manual diverter to divert the flow between the overhead shower and the shower hose and handset. The spout outlet incorporates a plastic aerator. The inlets and the outlet to the shower handset all incorporate an approved check valve cartridge, however, the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C
Two-hole, single outlet (fixed) combination tap assembly with brass body (chrome plated), incorporating quarter turn ceramic disc headworks with single lever operating members and a self-cancelling diverter to the shower outlet. The spout outlet incorporates a plastic flow straightener, and the product is supplied with metal backnuts. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.
A two-hole single outlet (fixed) combination tap assembly with brass body (chrome plated), incorporating a quarter turn ceramic disc headwork with single lever operating members and a self-cancelling diverter to a shower outlet. The spout incorporates a waterfall outlet. The inlets incorporate plastic flow restrictors. This product is supplied with a shower hose and handset and metal back nuts. Maximum working pressure 6.0 bar. Maximum operating temperature 60°C.
Two-hole, single outlet (fixed) combination tap assembly (chromium plated brass), incorporating quarter turn ceramic disc headworks with single lever operating members and a self-cancelling diverter to shower outlet. The spout outlet incorporates a plastic flow straightener. The product is supplied with a shower hose and handset and metal back nuts. Maximum working pressure 6.0 bar. Maximum operating temperature 60°C.
Range of two-hole, single outlet (fixed) combination tap assemblies (chromium plated brass), incorporating quarter turn ceramic disc headworks with single lever operating members or non-rising spindle headworks and a self-cancelling diverter to shower outlet. The spout outlet incorporates a plastic flow straightener. The products are supplied with a shower hose and handset and metal back nuts. Maximum working pressure 6.0 bar. Maximum operating temperature 60°C.
Two-hole, single outlet fixed combination tap assembly (chromium plated brass) incorporating quarter turn ceramic disc headworks with single lever operating members and a lockable self-cancelling diverter to shower outlet. The spout outlet incorporates a plastic flow straightener The product is supplied with a shower hose and handset and metal backnuts. Maximum working pressure 10.0 bar. Maximum working temperature 60°C.
Range of three hole, single outlet (fixed) wall mounted, concealed tap assemblies with brass bodies and chrome plated trim set. Consisting of a rough in set 45089 and extermnal trim 65090 and 65091. Incorproating a quarter turn ceramic disc headworks and single lever operating members.The spout outlet incorporates a plastic aerator. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.
Range of three hole, single outlet (fixed) combination tap assemblies incorporating chrome plated brass bodies, quarter turn ceramic disc headwork with lever type operating members. The spout outlets incorporate a plastic aerator. The product is supplied with stainless steel braided PEX lined flexible hose assemblies to connect between the valves and spout Model 23484W-4-CP is supplied with pop up waste. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.
Range of three hole, single outlet (fixed) combination tap assemblies with brass bodies (chrome plated) incorporating quarter ceramic disc headworks and various operating members (see model). The spout outlet incorporates a plastic aerator. The product is supplied a click type waste and stainless steel braided EPDM lined flexible hose assemblies for connecting the side body headworks and the spout junction. Maximum working pressure 5.5 bar. Maximum working temperature 60 °C.
A range of four-hole single outlet fixed combination tap assemblies with brass bodies in a variety of finishes (See models). Incorporating ¼ ceramic disc headworks with single lever operating members and a self-cancelling diverter to a shower outlet. The spout outlet incorporates a plastic aerator. The shower outlet elbow incorporates an approved check valve cartridge; however, the complete product has not been fully tested to demonstrate it provides backflow protection. This product is supplied with a shower hose, shower handset and metal screw clamp type back nuts. The side valves and the spout are connected with a copper tube. Maximum working pressure 10 bar. Maximum working temperature 60 °C.
Expansion vessels incorporating a stainless steel body and EPDM membrane. Maximum working pressure 10.0 bar. Maximum operating temperature 100˚C.
ERA-01 range of SDR11 and SDR17 polyethylene butt welded fittings for use with ERA-02 range of SDR11 and SDR17 PE 100 pipe. SDR11 rated pipe and fittings have a maximum working pressure of 16.0 bar. SDR17 rated pipe and fittings have a maximum working pressure of 10.0 bar. For above and below ground use. Cold water use only.
Range of copper press fittings with EPDM seals for use with EN1057 copper tube. The joints are achieved by means of a press tool. Maximum working pressure 16.0 bar. Maximum operating temperature 99°C.
Range of press-fit end connectors (gunmetal bodies) for use with copper pipe manufactured to BS EN 1057. Maximum working pressure 16.0 bar. Maximum operating temperature 99°C.
‘HE-705X & HE-715X’ ranges of brass crimp fit fittings incorporating EPDM ‘O’-rings for use with copper pipe (manufactured to EN1057-2006). HE-7052/7053/7058/7059 & HE-7152/7153/7158/7159 models also incorporate a NBR gasket. Maximum working pressure 16.0 bar. Maximum operating temperature 85°C.
VSH XPRESS Range of copper press fittings with EPDM rubber ‘O’-rings for use with copper pipe (manufactured to EN 1057). Maximum working pressure 16.0 bar. Maximum operating temperature 85°C.
Range of end feed copper solder fittings for use with copper tube. Maximum working pressure 16.0 bar. Maximum operating temperature 99°C.
Range of air cooled ice making machines . Inlet is controlled via solenoid valve. Maximum working pressure 5.5 bar. Cold water use only.
Aquila V5 range of water meters with black epoxy coated cast iron bodies, plastic turbines, fibre/NBR flange gaskets and either NBR or EPDM ‘O’-rings. Maximum working pressure 16.0 bar. Cold water use only.
Range of ultrasonic water meters with brass bodies incorporating EPDM ‘O’-rings. The inlets incorporate a plastic strainer. The DN15 X 165mm and DN20 X 190mm models incorporate a non-return valve on the outlet. Maximum working pressure 16.0 bar. Maximum operating temperature 50°C.
Range of water meters with a brass body, EPDM ‘O’-rings and seal. The products incorporate an internal plastic strainer and an optional combined plastic and stainless-steel strainer on the inlet. Maximum working pressure 16.0 bar. Cold water use only
Range of water meters with blue epoxy coated iron bodies and EPDM ‘O’-rings. Maximum working pressure 16.0 bar. Maximum operating temperature 85°C.
Range of single-jet water meters with brass bodies and a plastic strainer on the inlet. Maximum working pressure 16.0 bar. Maximum operating temperature 90°C.
MJ (Multi jet) range of water meters with either ductile iron (MJF model) or brass (MJ models) blue epoxy coated bodies and EPDM rubber ‘O’-rings. Maximum working pressure16.0 bar. Maximum operating temperature 85°C.
Range of ‘Resident Valves’ with a DZR brass body consisting of water meter manifold, an isolation valve on the inlet, a pressure reducing valve (adjustable between 1.5 and 6.0 bar) and 2 non-return valves which are located on the outlet of the water meter manifold. The ‘Plus’ models are also supplied with an isolation valve on the outlet, which incorporates a drain tap. Maximum supply pressure 16.0 Bar. Cold water above ground use only.
Range of radial flowmeters incorporating EPDM ‘O’-rings. The type 10088400 model has a black plastic body and threaded inlet. The type 10088402 model has a pale olive green plastic body with a threaded brass inlet incorporating a plastic filter. Maximum working pressure 10.0 bar. Maximum operating temperature 65°C.
Plastic bodied flow sensor with silicone gaskets. Maximum working pressure 17.5 bar. Maximum operating temperature 85°C.
Range of in line regulating valves DZR brass bodies, EPDM ‘O’-rings and PTFE seals. Maximum working pressure 20.0 bar. Maximum operating temperature 85°C.
Y type fittings incorporating brass body and NBR washer. Maximum working pressure 10.0 bar. Maximum operating temperature 85°C.
Thermally activated water saving valve with a plastic body and non-return valves on the hot and cold outlet. Maximum working pressure 5.0 bar. Maximum operating temperature 65°C.
Y type fittings incorporating brass body and NBR washer. Maximum working pressure 10.0 bar. Maximum operating temperature 85°C.
Circulation pump incorporating a plastic body and impellers. Maximum working pressure 15.0 bar. Maximum operating temperature 95°C.
‘Showermate Universal’ range of booster pumps with plastic bodies and impellers, stainless steel shafts, brass manifolds, NBR ‘O’-rings and EPDM seals. The product incorporates a pressure vessel. The outlet(s) incorporate(s) an approved single check valve cartridge however, the complete product has not been fully tested to demonstrate it provides backflow protection The inlet hose(s) supplied with this product incorporate(s) an isolation valve. Maximum working pressure 4.0 bar. Maximum operating temperature 65°C.
Range of cold water in tank booster sets incorporating an ‘AG’ air gap, consisting of a GRP water storage cistern incorporating a float operated inlet valve, with a copper float and submersible pump or pumps (depending on model). The products incorporate an externally mounted stainless-steel manifold with servicing valve(s), expansion vessel, pressure gauge and a digital control panel. The pumps are connected to the external components via a discharge assembly of internal pipework including an in-line non-verifiable single check valve assembly (suitable for backflow prevention of Fluid Category 2). Maximum working pressure 10.0 bar. Cold water use only.
Range of cold water in tank booster sets incorporating an ‘AB’ air gap, consisting of a GRP water storage cistern incorporating a float operated inlet valve, with a copper float and submersible pump or pumps (depending on model). The products incorporate an externally mounted stainless-steel manifold with servicing valve(s), expansion vessel, pressure gauge and a digital control panel. The pumps are connected to the external components via a discharge assembly of internal pipework including an in-line non-verifiable single check valve assembly (suitable for backflow prevention of Fluid Category 2). Maximum working pressure 10.0 bar. Cold water use only.
Range of pumps with stainless steel bodies and plastic impellors. Maximum working pressure 16.0 bar. Maximum operating temperature 95°C.
Range of shower handsets (chromium plated) brass bodies and NBR O-rings. The inlets incorporate stainless-steel strainers and approved check valve cartridges, however, the complete product has not been fully tested to demonstrate it provides backflow protection. Open outlet use only. Maximum operating temperature 60ºC
A range of shower kits and hand showers incorporating metal bodies (chrome plated). Some models are supplied with sliding rails, wall elbows and shower hoses (see models). Maximum working temperature 60°C.
Range of overhead shower outlets with brass bodies in various finishes (See models) incorporating EPDM ‘O’-rings and seals. The inlet to the shower heads incorporate either a plastic steel sieve (26 031 xxx) or a stainless steel (26 032 xxx) has a stainless-steel sieve. The inlet for the shower head incorporates an approved check valve cartridge, however, the complete product has not been fully tested to demonstrate it provides backflow protection (Model 26 031 xxx only). Maximum operating temperature 60°C.
Range of plastic shower handsets (various finishes). Maximum operating temperature 75°C.
Range of overhead shower outlets with stainless steel bodies (various finishes). The inlet incorporates a stainless steel filter and a plastic flow regulator. Maximum working temperature 60°C.
Range of wall mounted shower outlets with a brass bodies (chrome plated). The outlet incorporates a single check valve cartridge however, the complete product has not been fully tested to demonstrate it provides backflow protection Maximum operating temperature 60°C.
Range of overhead shower outlets incorporating metal bodies (various finishes) and flow regulator and strainer on the inlets. Maximum operating temperature 43°C.
Range of overhead shower outlets incorporating metal bodies (various finishes) and flow regulator and strainer on the inlets. Maximum operating temperature 43°C.
Range of shower kits, comprosing of shower handset, shower hose, riser rail and overhead shower outlet depending on kit. Inlets incorporate a flow regulator (models 1.1740.578 & 1740.155) Maximum operating temperature 60°C.
Range of overhead showers with brass and plastic bodies (various finishes - see models). The inlet incorporates a stainless-steel strainer and a plastic strainer. Products to be used with basic sets with brass bodies and EPDM O-rings. Open outlet use only
Non-metallic materials and components comply with BS6920 at 60°C
Range of filter type fixed ‘shower’ outlets and shower handsets with plastic bodies. Maximum operating temperature 45°C.
Range of shower rose outlets (plastic body with various finishes). The inlet incorporates a stainless-steel strainer. Maximum operating temperature 60°C. Open outlet use only.
Range of showers handsets with plastic bodies (various finishes - see model). All models incorporate a stainless steel strainer, the EcoSmart models also incorporate a plastic flow regulator. Maximum operating temperature 60°C.
Range of shower handsets with brass bodies available in various styles and finishes. The inlets incorporate an approved check valve cartridge, however, the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum operating temperature 60°C.
Range of shower handsets, shower heads, shower kits (consisting of wall outlet with bracket, shower hose and shower handset) and a 90-degree wall outlet elbow all with brass bodies (various finishes - see model). Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.
‘Concept’ & ‘Advance’ ranges of atmospheric steaming ovens. The products incorporate a retractable triple layered hose on a reel and a push-button operated shower handset. The inlet of the shower handset incorporates a single check valve cartridge however, the complete product has not been fully tested to demonstrate it provides backflow protection The water supply is controlled via a solenoid valve. The retractable hose has its own dedicated supply also controlled via a solenoid valve. The products are supplied with dual layer supply hoses (grey PVC outer layer/black PVC inner layer) with ¾” captive nut end connections, and chrome plated DZR brass ½” BSP (F) x ¾” BSP (M) double check valve assemblies (suitable for backflow protection against Fluid Category 3) for installation on each inlet. Maximum working pressure 4.0 bar. Cold supply only.
Range of flow switches incorporating brass or stainless steel bodies. Maximum working pressure 25.0 bar. Maximum operating temperature 100°C.
Range of flow sensors with brass or plastic bodies. Flow sensor type series VTY10 (plastic body, G3/4): Maximum working pressure 10.0 bar. Maximum operating temperature 85°C. Flow sensor type series VTY10 (plastic body, Quickfasten OD 22.5mm): Maximum working pressure 10.0 bar. Maximum operating temperature 70°C. Flow sensor type series VTY10 (brass body, G1/2): Maximum working pressure 16.0 bar. Maximum operating temperature 90°C.
Turbine flow sensors with a plastic bodies. Maximum working pressure 10.0 bar. Maximum operating temperature 80°C
Pillar tap (chromium plated brass) , incorporating a quarter turn ceramic disc headwork with a single lever operating member. The spout outlet incorporates a stainless steel aerator and the product is supplied with a metal backnut. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.
Range of pillar taps (chromium plated brass) incorporating quarter turn ceramic disc headworks with a single lever operating members. The spout outlet incorporates a plastic flow straightener. The product is supplied with metal backnuts. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C
Range of pillar taps incorporating brass bodies (chrome plated), non-rising spindle headworks (models TPN0RBAS2 & TPN0RBATH2 or quarter turn ceramic disc headworks (all other models). The spout outlet incorporates a flow straightner. Maximum working pressure 6.0 bar. Maximum operating temperature 60°C.
Self-closing tap (chromium plated brass) incorporating spring loaded headworks incorporating a dome type operating member, with a single lever operating member controlling the temperature. The spout outlet incorporates a plastic aerator. The inlet hoses incorporate a check valve cartridge, however, the complete product has not been fully tested to demonstrate it provides backflow protection Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.
PEX lined flexible hose assemblies with either nylon or stainless-steel braiding and a variety of end connectors. Some models are supplied with screwdriver operated isolation valves. Maximum working pressure 10.0 bar. Maximum operating temperature 85°C.
Flexcore® Range of polyethylene lined flexible hoses incorporating (stainless steel or polyamide braiding and various end connections. Maximum operating temperature 65°C.
Range of shower hoses available in a variety of external sheath materials and finishes (see models) with EPDM washers. Maximum operating temperature 65°C.
EPDM lined flexible hose assemblies with either nylon or stainless-steel braiding and a variety of end connectors. Some models are supplied with screwdriver operated isolation valves. Maximum working pressure 10.0 bar. Maximum operating temperature 85°C.
Range of multi-layer shower hoses with a PVC inner hose, supplied with EPDM ‘O’-rings. Maximum operating temperature 60°C.
Range of multi-layered flexible hoses (TPE inner liner/PVC middle/PVC outer with polyester braiding in-between) and stainless-steel braided EPDM flexible hoses. The hoses are supplied with a variety of end connections incorporating brass barbed hose inserts or white plastic barbed hose inserts. The hoses may also incorporate a servicing valve (see model). The push fit connectors are to be used with copper pipe (Manufactured to EN1057), PB pipe (Manufactured to BS EN21003) & PE-x pipe (manufactured to BS EN7291-3). Products shown with a “P” suffix (eg. WFLX15P, FLX43P) are a prepacked variant of the original product eg. WFLX15, FLX43. Products shown with a “SB” suffix (eg. FLX15P-SB, WFLX28-SB) are a reduced box quantity of an existing product. Maximum working pressure and operating temperature: 12.0 bar @ 20°C and 6.0 bar @ 65°C.
Range of PVC and PEX lined shower hose with EPDM washers. Maximum operating temperature 65°C.
Range of stainless steel flexible connectors, incorporating carbon steel flanged connections (zinc plated) and corrugated stainless steel bellow. Maximum working pressures:16.0 bar (JP23VS NP16 models) or 25.0 bar (JP23VS NP25 models). Maximum operating temperature 100°C.
Range of wall mounted, concealed, blending valve, incorporating brass bodies (chrome plated), quarter turn ceramic disc headworks with single lever operating members and a manual diverter diverting the flow to two outlets. Maximum working pressure 5.0 bar. Maximum operating temperature 65°C.
Range of concealed, wall mounted, electronically controlled blending valves (brass body). The flow is controlled via a solenoid valve actuated via an infra-red sensor. Inlets to the sensor box incorporate stainless steel strainers. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C
Wall mounted, manually operated, concealed blending valves with cast brass bodies with chromium plated faceplates, incorporating a ceramic cartridge headwork with a single lever operating member controlling both flow and temperature. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.
Range of concealed thermostatic blending valves with brass bodies (chrome plated), incorporating a manual diverter to two outlets with an off position (model XB-AZ-037A), two ceramic disc headworks controlling the flow to both outlets (model XB-AZ-035A) or one outlet controlled via a ceramic disc headwork (model XB-AZ-034A). The temperature is controlled via a thermostatic cartridge with various operating members (see models). Inlets incorporate stainless-steel strainers and approved check valve cartridges however, the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum working pressure 10.0 bar. Maximum operating temperature 65°C.
Range of wall mounted, bar-type thermostatic shower valves with brass bodies (chromium plated), incorporating a quarter ceramic disc headwork controlling the flow with a dome type operating member. Temperature is controlled independently via a thermostatic cartridge using a dome type operating member which incorporates a manual override button. Both inlets incorporate a stainless steel strainer and an approved check valve cartridge, however, the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum working pressure 10.0 bar. Maximum operating temperature 65°C.
Range of wall mounted concealed thermostatic blending valves incorporating brass bodies with chrome plated trim sets, incorporating 1,2 or 3 way diverter valves (see models) controlling the flow with a single lever type operating member. Temperature is controlled independently via a thermostatic cartridge with a dome type operating member. The inlets incorporate approved check valve cartridges however, the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.
Range of wall mounted thermostatic shower blending valves incorporating brass bodies and an external trim set (various finishes). Flow is controlled to each shower outlet via individual ‘detent’ (push to on push to off) headworks. The temperature is controlled independently via a thermostatic cartridge with a dome type operating member that incorporates a manual override button. Both inlets incorporate an approved check valve cartridge, however the complete product has not been fully tested to demonstrate it provides backflow protection. The product is supplied with a shower hose, shower handset, riser rail and overhead shower outlet. The product is also supplied with two loose plastic flow regulators for installation between the valve and the shower hose, as well as on the inlet to the overhead shower. Maximum working pressure 5.0 bar. Maximum operating temperatures: shower handset 50°C, all other items 65°C.
Range of wall mounted, thermostatic, shower mixers incorporating brass bodies (various finishes) 2-way ceramic disc diverter headwork to control the flow between two shower outlets with various operating members (see model). The A47203VUK model uses two ‘detent’ (push to on push to off) headworks to control the flow to each outlet. Temperature is controlled independently via a thermostatic cartridge using various operating members (see model) that also incorporates a manual override button. The inlets incorporate a combined EPDM washer and stainless-steel strainer or stainless steel strainer (A47203VUK model) and an approved check valve cartridge, however, the complete product has not been fully tested to demonstrate it provides backflow protection. The inlet of the overhead shower incorporates a combined EPDM washer and stainless-steel strainer. The products are supplied with a shower head, shower hose and handset. Maximum working pressure 10.0 Bar. Maximum operating temperature 60°C.
Wall mounted thermostatic blending valves (chromium plated brass), incorporating ceramic disc headwork with a dome type operating member and a manual diverter which diverts the flow between an over head shower and a bath. The temperature is controlled independently via a thermostatic cartridge incorporating a manual override button with a dome type operating member. The inlets incorporate stainless steel strainers and approved check valve cartridge, however, the complete product has not been fully tested to demonstrate it provides backflow protection. The spout outlet incorporates a plastic aerator. Maximum working pressure 5.0 bar. Maximum operating temperature is 60°C.
Range of deck mounted, flow control valves (brass bodies), incorporating a quarter turn ceramic disc headwork with either a cross top or single lever operating member (see models). The products are supplied with a metal backnuts. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.
In-line adjustable pressure reducing valve assembly with a DZR brass body. The assembly also incorporates a stainless strainer (part of the pressure reducing valve), a spherical valve with a brass ball on the inlet, a single check valve cartridge, verified by test (suitable for backflow protection against Fluid Category 2) on the outlet, and a drain port with a brass plug. The product also includes a port with a plastic plug to accommodate a gauge/sensor (not supplied). Adjustable outlet pressure range between 1.0 and 6.0 bar. Maximum supply pressure 10.0 bar. Maximum operating temperature 85°C.
Monobloc assembly with a DZR brass body comprising of a stainless steel strainer, adjustable pressure reducing valve and two approved check valve cartridges, however, the complete product has not been fully tested to demonstrate it provides backflow protection. The product is supplied with two loose pressure gauges. For use with copper pipe (manufactured to EN1057). The product is also supplied with Maximum inlet supply pressure 6.0 bar. Maximum outlet pressure 0.8 bar to 6.0 bar. Maximum operating temperature 35°C.
Range of pre-set, spring loaded, angled pressure relief valves, with a plastic body and EPDM diaphragm. The B312021 CST model only is pre-set at 4.0 bar, all other models are pre-set at 3.0 bar. The valves are fitted with either rotary type easing gear or hand operated lifting gear. Maximum operating temperature 99°C.
Range of bronze bodied pre-set pressure relief valves (available between 0.2-16 bar on each model) incorporating a manually operated easing gear with brass seat and PTFE or EPDM washers.
Non-metallic materials and components comply with BS6920 at 85°C
Range of bronze bodied pre-set pressure relief valves (available between 0.2-16 bar on each model) incorporating a manually operated easing gear with brass seat and PTFE or EPDM washers. Maximum operating temperature 85°C.
Range of latching and non-latching solenoid valves with brass bodies and an integral stainless-steel strainer. X262513141 (abc) (dd) models have a NBR ‘O’-Ring and diaphragm, all other models have an EPDM ‘O’-Ring and diaphragm. Maximum working pressure: see model. Maximum operating temperatures: X262513141(abc)(dd) models 65°C, all other models 85°C.
Solenoid valve incorporating a plastic body and an EPDM diaphragm. The product incorporates a plastic flow regulator with an EPDM washer, and a plastic filter on the inlet. Maximum working pressure 10.0bar. Maximum operating temperature 60°C.
Range of spherical valves incorporating stainless steel strainers, chrome plated brass ball, housed within DZR brass bodies with a brushed chrome finish. Maximum working pressure 16.0 bar. Maximum operating temperature 85°C
Range of straight, angled, tee and Y shaped isolation valves incorporating brass bodies, NBR ‘O’-rings or PTFE seats depending on model variant. Maximum working pressure 10.0 bar. Maximum operating temperature 85°C.
Range of lever operated spherical valves with a brass body and ball (brushed chrome plated), and PTFE seals. Maximum working pressure 42.0 bar (¼”, 3/8”, ½”, ¾” models) Maximum working pressure 32.0 bar (1”, 1 ¼”, 1 ½”, 2” models) Maximum working pressure 28.0 bar (2 ½” model) Maximum working pressure 16.0 bar (3” & 4” models) Maximum operating temperature 85°C
Range of straight, angled, tee and Y shaped isolation valves incorporating brass bodies, NBR ‘O’-rings or PTFE seats depending on model variant. Maximum working pressure 10.0 bar. Maximum operating temperature 85°C.
Range of quarter turn PVC-U double union spherical valves with EPDM seals and PTFE Seats. Maximum working pressure 16.0 bar. Cold water use only
Range of gate valves incorporating brass bodies, NBR, PTFE and fibre seals. For use with copper pipe (EN 1057) Maximum working pressure 16.0 bar. Maximum working temperature 85°C.
Range of gate valves with bronze bodies and PTFE seals. The valves incorporate a non-rising stem and hand-wheel or lock shield operating members (see models). Maximum working pressure 20.0 bar. Maximum operating temperature 100ºC.
Range of ion exchange water softeners (salt regenerated) for domestic use. Maximum working pressure 6.0 bar. Cold water use only.
'Cage Overmould 214867'. Black coloured, injection moulded ABS component. For use with water up to 70°C.
'ABS-001 (natural - appears off-white), ABS-002 (white), ABS-003 (grey), ABS-004 (blue), ABS-005 (green) & ABS-006 (pink)'. Injection moulded ABS (with Biomaster 612 added) materials. For use with water up to 70°C.
‘Inertol BS10’. Factory applied, black coloured bitumen coating. Apply and cure as per manufacturer’s instructions 'BF-T06', issue number '03' dated 01.12.2021. For use with water up to 60°C. Petroleum or asphaltic bitumen, NOT coal tar bitumen. Materials listed in this section are not approved for use for contact with water that is required to be wholesome on large water retaining structures such as lining of pipes, cisterns or water storage tanks.
‘PAM-MORTAR.D2'. Grey coloured (once mixed), factory applied Blast Furnace Slag Cement Mortar and admixture. Mix cement, sand, water & admixture in a mass ratio of 1:1.25:0.38:0.0008. Apply as per manufacturer’s technical data sheet dated 18/03/2021 (3rd revision) and cure for 48 hours@20°C. For use with water up to 60°C. This material is only approved for the mixing and curing conditions that appear on the approval. If the mixing and/or curing conditions are varied from those specified on the approval then the material is not covered by the scope of the approval.
'V- SRPC Portland Cement'. Factory applied, grey coloured Portland Cement. Mixx Sand:water:cement in a weight ratio of 0.6:1.0:0.22. Cure for 96 hours@26°C and then 576 hours@32°C. For use with water up to 65°C.
'Tecnocoat P-2049'. Factory applied, two component, grey coloured polyurea coating. Mix components A & B in a weight ratio of 1:1 and apply as per manufacturer's TDS 'v. 20-03-2022'. Cure for 48 hours@23°C. Between September 2022 and August 2024, the coating is for use with water up to 23°C. From September 2024, the coating is for use with water up to 60°C. This material is only approved for the mixing, curing & soaking conditions that appear on the approval. If the mix/cure/soak conditions are varied from those specified on the approval then the material is not covered by the scope of the approval.
'Relipoxy 342 Food Grade Epoxy Coating'. Factory applied, brown-red coloured epoxy coating. Apply as per manufacturer's 'Standard Operating Procedure & Guidelines' issue number '116/2021' dated 15th Feb 2021. Cure for 24 hours@30°C. For use with water up to 23°C. This material is only approved for the curing conditions that appear on the approval. If the cure conditions are varied from those specified on the approval then the material is not covered by the scope of the approval.
'Apcoguard SF 157'. Factory applied, grey coloured, two-component epoxy coating. Mix in a 3:1 volume ratio. Apply as per manufacturer's Application Guidelines 'APPPG/SF157/001' dated 'Jan-2021'. Cure for 7 days@25°C. For use with water up to 65°C. This material is only approved for the curing conditions that appear on the approval. If the cure conditions are varied from those specified on the approval then the material is not covered by the scope of the approval.
'Interline 925GF (White)'. Site applied, white coloured, two-component, solvent free epoxy coating. Mix part A (white liquid) with part B (off-white liquid) in a volume ratio of 3:1 and apply as per manufacturer's instructions '2253' dated 29/11/2011. Cure for 7 days@25°C. For use with water up to 60°C. This material is only approved for the mixing and curing conditions that appear on the approval. If the mixing and/or curing conditions are varied from those specified on the approval then the material is not covered by the scope of the approval.
'Interline 925 White'. Site applied, two-component, white coloured epoxy coating. Mix part A (off-white white coloured liquid) and part B (off-white coloured liquid) in a volume ratio of 3:1 and apply as per manufacturer's instructions ref. '2252', issue date 17/12/2020. Cure for 7 days@25°C. Between January 2022 and August 2022, the coating was for use with water up to 23°C. Between September 2022 and January 2027, the coating is for use with water up to 60°C. This material is only approved for the mixing and curing conditions that appear on the approval. If the mix and/or cure conditions are varied from those specified on the approval then the material is not covered by the scope of the approval.
'AXIL-76/T-MD'. White coloured (translucent), extruded silicone rubber hose. Shore hardness 80. Tested in-radius size between 0.75mm & 2.1mm. For use with water up to 85°C.
`BK Standard Lubricant`. Clear (colourless), translucent, soap based lubricant paste. For use with water up to 60°C.
'PlumbSil & PlumbSil HT'. Colourless silicone greases. Apply as per manufacturer's instructions dated 18th Jan 2022. For use with water up to 65°C.
'Hitemp 160'. Natural (appears off-white), extruded bearing material. For use with water up to 65°C.
'Turbine Overmould 208399'. Black coloured, injection moulded, strontium ferrite filled nylon 6 component. For use with water up to 70°C.
'NEWPRO HDPE Pipe'. Black coloured, extruded HDPE pipe. For use with water up to 65°C.
'EPDM60BKFG, EPDM65BKFG, EPDM70BKFG, EPDM75BKFG & EPDM80BKFG'. Black coloured, compression moulded EPDM rubbers. Shore hardness between 60A & 80A. Tested in-radius size 1.0mm. For use with water up to 70°C.
0713.23/60 (shore hardness 60A). 0713.23/65 (shore hardness 65A). 0713.23/70 (shore hardness 70A). 0713.23/75 (shore hardness 75A). 0713.23/80 (shore hardness 80A). 0713.23/85 (shore hardness 85A). Black coloured, compression moulded EPDM rubber materials. Tested in-radius size 1.0mm. For use with water up to 85°C.
'7PD1612 washers'. Black coloured, extruded NBR rubber washers. Tested in-radius size 1.4mm. Shore hardness 70. '7PD1612 'O' rings'. Black coloured, injection moulded NBR rubber `O` rings. Tested in-radius size 0.9mm. Shore hardness 70. Both for use with water up to 60°C.
'SA-LHS'. Black coloured, extruded PVC material. For use with water up to 65°C.
A range of single-hole, single outlet (fixed (model 62816) or swivel (models 63407)) electronically controlled tap assemblies with brass bodies in various finishes (see models). Flow is controlled by a solenoid valve activated via an infra-red sensor and a ceramic cartridge with a single lever operating members controlling both the flow and temperature for all models excluding 62816, which uses a mixer to control the temperature only with a single lever operating member. The spout outlets incorporate plastic aerators. All models (excluding 63407) incorporate a separate approved check valve cartridge on the inlet, verified by test (suitable for backflow protection against Fluid Category 2), The inlets of all models incorporate stainless steel strainers. Maximum working pressure 5.0 bar Maximum working temperature 60°C.
Single-hole, single outlet, swivel electronically controlled tap assembly with a brass body in various finishes (see model). Flow is controlled by a solenoid valve activated via an infra-red sensor and a ceramic cartridge with a single lever operating member controlling both the flow and temperature. The spout outlet incorporates a pull-out spray with a plastic aerator. The inlets incorporate approved check valve cartridges, verified by test (suitable for backflow protection against Fluid Category 2), and a stainless-steel strainer Maximum working pressure 5 bar. Maximum working temperature 60°C.
Range of side entry BS1212-4 (2016) compact type float operated valves for WC flushing cisterns. The inlet incorporates a strainer. Maximum working pressure 10.0 bar. Cold water use only.
Range of concealed WC flushing cisterns incorporating a side entry compact type float operated inlet valve providing a Type AG air gap with a dual flush drop valve for full flush volumes of up to 6 litres and a reduced flush of up to 4 litres. The cistern is operated by a manual push button and incorporates a servicing valve and flexible hose on the inlet supply. Maximum working pressure 10.0 bar. Cold water use only.
Range of concealed WC flushing cisterns incorporating a side entry BS1212-4 (2016) compact type float operated inlet valve providing a Type AG air gap with a dual flush drop valve for full flush volumes of up to 6 litres and a reduced flush of up to 4 litres. The cistern is operated by a manual push button and incorporates a servicing valve and flexible hose on the inlet supply. Maximum working pressure 10.0 bar. Cold water use only.
Range of concealed WC flushing cisterns incorporating a side entry compact type float operated inlet valve providing a Type AG air gap with a dual flush drop valve for full flush volumes of up to 6 litres and a reduced flush of up to 4 litres. The cistern is operated by a manual push button and incorporates a servicing valve and flexible hose on the inlet supply. Maximum working pressure 10.0 bar. Cold water use only.
BS EN 14055 (2018) WC Cistern incorporating a side or bottom entry float operated inlet valve discharging via a Type AG air gap and a lever operated dual flush syphon with full flush volumes of up to 6 litres and a reduced flush of up to 3 litres. Maximum working pressure 10.0 bar. Cold water use only.
WC flushing cistern incorporating a side entry BS1212-4 (2016) compact type float operated inlet valve providing a Type AG air gap with a dual flush drop valve for full flush volumes of up to 6 litres and a reduced flush of up to 3 litres and incorporates a servicing valve and flexible hose on the inlet supply.The cistern is operated by a pnuematic push button Maximum working pressure 10.0 bar. Cold water use only.
Concealed WC dual flushing cistern with a BS 1212-4(2016) float operated inlet valve providing a Type AG air gap arrangement and a dual flush pneumatic outlet valve. The flush valve is operated by a two-push button assembly for a 6 or 3 litre flush volume. Maximum working pressure - 10 Bar, cold water use only.
Range of WC flushing cisterns incorporating a BS 1212-4 (2016) side entry compact type float operated inlet valve providing a Type AG air gap with a dual flush drop valve for full flush volumes of up to 6 litres and a reduced flush of up to 4 litres or 4.5/3 litre flush volumes. The cistern is operated by a manual push button and the product incorporates a servicing valve on the inlet supply. Maximum working pressure 10.0 bar. Cold water use only.
Range of floor mounted, single hole, single outlet (fixed), combination tap assemblies (chromium plated brass), incorporating a ceramic cartridge headwork with a single lever operating member and a manual diverter to shower outlet. The spout outlet incorporates a plastic aerator (SH-T9050N model) or a plastic flow straightener (all other models). Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.
Double check valve assembly consisting of two spring loaded resilient trim in-line check valve cartridges housed in a DZR brass body with a drain port located between the cartridges. For use with copper pipe manufactured to BS EN1057. Maximum working pressure 16.0 bar. Maximum operating temperature 85°C.
Single hole, single outlet (fixed, with swivel nozzle) bidet combination tap assemblies (chromium plated brass) incorporating ceramic cartridge headwork with single lever operating member. The spout outlets incorporate a plastic aerator. Supplied with a pop-up waste. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.
Range of ceramic disc diverter cartridges with plastic bodies and silicon ‘O’-rings, for insertion into specifically dimensioned bores. Maximum working pressure 16.0 bar. Maximum operating temperature 85°C.
Range of ceramic cartridge headworks with plastic bodies and EPDM ‘O’-rings, for insertion into specifically dimensioned bores. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.
Range of four-hole, single outlet (swivel) combination tap assemblies (brass bodies, chrome plated or brushed steel finish) with a spout outlet and flexible hand spray outlet. The hot water is controlled to the spout outlet only (not to the spray outlet) via a quarter turn ceramic disc headwork with single lever operating member. The cold water to the spout outlet and trigger-operated spray outlet is controlled and diverted via a ceramic disc diverter headwork. The product is supplied with Stainless steel braided EPDM lined flexible hose assemblies for connection between the headworks and spout. The spout outlet incorporates a plastic aerator and the products are supplied with metal back nuts. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.
Range of single hole, single outlet (swivel) combination tap assemblies (brass bodies - various finishes - see model), incorporating a ceramic cartridge headwork with a single lever operating member. The product incorporates a pull-down spout with a plastic aerator, which also incorporates an approved single check valve cartridge, however, the complete product has not been fully tested to demonstrate it provides backflow protection. The product is supplied with optional ⅜” BSP (M) x ½” BSP (F) adaptors each with two fibre gaskets for installation on each inlet hose. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.
Range of single hole, single outlet (fixed) combination tap assemblies (brass bodies, various finishes - see model), incorporating a ceramic cartridge headwork with a single lever operating member. The spout outlet incorporates a plastic aerator. The products can be supplied with a pop-up or click type waste (see model). Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.
Range of floor standing single hole, single outlet (fixed) combination tap assemblies (chromium plated brass), incorporating a ceramic cartridge headwork with a single lever operating member. The spout outlet incorporates a plastic aerator. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.
Range of single hole, single outlet (fixed) combination tap assemblies (chromium plated brass), incorporating a ceramic cartridge headwork and a single lever operating member. The spout outlet incorporates a plastic aerator. The V709/V7K09 based models are supplied with a pop-up waste. Maximum working pressure 5.0 Bar. Maximum operating temperature 60°C.
Range of single hole, single outlet (fixed) over the rim (swivel nozzle) bidet combination tap assemblies with brass bodies (various finishes), incorporating a ceramic cartridge headworks and single lever operating members. The spout outlet incorporates a plastic aerator and the product is supplied with a lever type pop-up waste. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.
Range of wall mounted single hole, single outlet (fixed) combination tap assemblies with brass bodies (various finishes), incorporating a ceramic cartridge headwork with a single lever operating member. The spout outlet incorporates a plastic aerator. The external part is supplied with a concealed rough part for connection to water supplies. Maximum working pressure 10.0 bar. Maximum operating temperature 65°C.
Range of single hole, single outlet (fixed) combination tap assemblies with brass bodies (various finishes), incorporating a ceramic cartridge headworks and single lever operating members, and the spout outlet incorporates a plastic aerator. The product can be supplied with or without a pop-up waste arrangement. Maximum working pressure 10.0 bar. Maximum operating temperature 65°C.
Single hole, single outlet fixed combination tap assemblies (Chromium plated brass), incorporating a ceramic cartridge headwork with a single lever operating member. The spout outlet incorporates a plastic aerator. Maximum operating pressure 10.0 bar. Maximum operating temperature 60°C.
Single hole, single outlet (fixed) combination tap assembly (chromium plated brass) incorporating a ceramic cartridge headwork with a single lever operating member. The spout outlet incorporates a plastic flow straightener. The product is supplied with a ⅜” BSP (M) x 15mm compression adapter for installation on each inlet hose. Maximum working pressure 10.0 bar. Maximum operating temperature 65°C.
Single-hole, single outlet, fixed combination tap assembly (chromium plated brass), incorporating a ceramic cartridge headwork with a single lever operating member and a waterfall type spout outlet. The inlet hoses incorporate a combiner washer and stainless-steel strainer. The products are supplied with two loose brass ½” BSP (M) x ½” BSP (F) adaptors for installation on each inlet hose. These adaptors incorporate an approved single check valve cartridge, verified by test (suitable for back flow protection against Fluid Category 2). The product is supplied with click type pop-up waste. Maximum working pressure 5.0 bar. Maximum working pressure 60°C.
Range of single hole, single outlet (fixed) combination tap assemblies (brass bodies, various finishes - see model), incorporating a ceramic cartridge headwork with a single lever operating member. The spout outlet incorporates a plastic aerator. The products can be supplied with waste outlets (see models). Maximum working pressure 10.0 bar. Maximum operating temperature 65°C.
Non-metallic materials and components comply with BS6920 at 70°C
Range of single hole, single outlet (fixed) combination tap assemblies with brass bodies (various finishes), incorporating ceramic cartridge headworks with single lever operating members. The spout outlets incorporate a plastic aerator. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.
Floor mounted single hole, single outlet (fixed) combination tap assembly (chromium plated brass), incorporating a ceramic cartridge headwork with a single lever operating member and a self-cancelling diverter to a shower outlet. The spout incorporates a plastic flow regulator and the shower outlet incorporates an approved check valve cartridge, however, the complete product has not been fully tested to demonstrate it provides backflow protection. This product is supplied with a shower hose and handset which incorporates an approved check valve cartridge, however, the complete product has not been fully tested to demonstrate it provides backflow protection. The spout outlet incorporates a plastic aerator. Maximum working pressure 10.0 bar. Maximum working temperature 60°C.
Single hole, single outlet (swivel) combination tap assembly (brass body, various finishes), incorporating a ceramic cartridge headwork with a single lever operating member. The spout outlet incorporates a plastic aerator. Maximum working pressure 10.0 Bar Maximum operating temperature 60.0°C
A range of single hole, single outlet (swivel) combination tap assemblies (brass bodies, various finishes - see model), incorporating quarter turn ceramic disc headworks with single lever operating members. The spout outlet incorporates a plastic aerator. The product is also supplied with an alternative spout outlet that incorporates a plastic flow straightener and a stainless-steel strainer. The products are supplied with a loose brass ½” BSP (M) x ½” BSP (F) adaptor for installation on the cold inlet. This adaptor incorporates a single check valve cartridge, verified by test (suitable for backflow protection against Fluid Category 2). Maximum working pressure 5.0 bar. Maximum working temperature 60°C.
Range of single hole, single outlet (swivel) combination tap assemblies with brass bodies (chrome plated), incorporating ceramic cartridge headworks with single leaver operating members. The spout outlet incorporates a plastic aerator. Maximum working pressure 5.5 bar. Maximum operating temperature 60°C.
Single hole, single outlet (swivel) combination tap assembly (chromium plated brass), incorporating quarter turn ceramic disk headworks with single leaver operating members. The spout outlet incorporates a plastic aerator. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.
Single hole, single outlet (swivel) combination tap assembly with brass body (chrome plated), incorporating quarter turn ceramic disc headworks with a single lever type operating members. The outlet incorporates a plastic flow straightener. Maximum working pressure 5.5 bar. Maximum operating temperature 60°C.
Range of single hole, single outlet (swivel) combination tap assemblies (chrome finish), incorporating a ceramic cartridge headwork with a single lever operating member. The spout outlet incorporates a plastic flow straightener. The product is supplied with a fixing kit that incorporates isolation valves with single check valve assemblies (verified by test - suitable for backflow protection against fluid Category 2). Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.
Range of single hole, single outlet (swivel) combination tap assemblies with brass bodies (chrome plated), incorporating ceramic cartridge headworks with single leaver operating members. The spout outlet incorporates a plastic aerator. Maximum working pressure 5.5 bar. Maximum operating temperature 60°C.
Range of single hole, single outlet (swivel) combination tap assemblies, brass bodies (various finishes) incorporating quarter turn ceramic disc headworks with cross top operating members. The spout outlet incorporates a plastic aerator. Supplied with a pop-up waste. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.
Range of floor mounted single hole, single outlet (swivel), combination tap assembly (chromium plated brass), incorporating a ceramic cartridge headwork with a single lever operating member and a manual diverter to shower outlet. The spout outlet incorporates a plastic aerator. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.
Range of two-hole, single outlet fixed combination tap assembly (chromium plated brass) incorporating quarter turn ceramic disc headworks with single lever operating members. The spout outlets incorporate a plastic flow straightener. The product is supplied with metal back nuts. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.
Range of two hole, single outlet, (fixed) combination tap assemblies (chromium plated brass), incorporates a quarter turn ceramic disc headwork with single lever operating members. The spout outlets incorporate a plastic flow straightener and the products are supplied with metal backnuts. . Maximum working pressure 10.0 bar. Maximum operating temperature 85°C.
Range of two-hole, wall mounted (fixed) combination tap assemblies with brass bodies (chrome plated), incorporating quarter turn ceramic disc headworks with single lever operating members and manual override button. The products incorporate a manual diverter to a shower outlet with a single lever operating member and the spout outlets incorporate plastic aerator. The products are supplied with a shower handset, shower hose and metal back nuts. Maximum working pressure 5.0 bar. Maximum working temperature 60°C.
Deck mounted, two-hole, single outlet (fixed) combination tap assembly (brass body with various finishes - see model), incorporating a 2 way ceramic disc diverter headwork controlling the flow between the spout or shower outlet with a single lever operating member. Temperature is controlled independently via a thermostatic mixing valve incorporating a single lever operating member with a manual override button. Each inlet incorporates an approved single check valve cartridge; however, the complete product has not been fully tested to demonstrate it provides backflow protection. The spout outlet incorporates a plastic aerator. The product is supplied with plastic backnuts. Maximum working pressure 10.0 Bar. Maximum working temperature 60°C.
Two hole, single outlet (fixed) combination tap assembly (chromium plated brass) incorporating quarter turn ceramic disc headwork, single lever operating members and self- cancelling diverter to shower outlet. The spout outlet incorporates a plastic flow straightener & the products are supplied with metal backnuts. The product includes a shower hose and handset. Maximum working pressure 10.0 bar. Maximum working temperature 70°C.
Range of two hole, single outlet (swivel) combination tap assemblies (brass bodies, various finishes - see model), incorporating quarter turn ceramic disc headworks with single lever operating members. The spout outlet incorporates a plastic aerator. The product is also supplied with an alternative spout outlet that incorporates a plastic flow straightener and a stainless-steel strainer. This product is supplied with metal backnuts. Maximum working pressure 5.0 bar. Maximum working temperature 60°C.
Two-hole, single outlet swivel combination tap assembly in various finishes (see model) incorporating quarter turn ceramic disc headworks with a cross top operating members. The spout outlet incorporates a plastic aerator. Supplied with a pop-up waste. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.
Range of two-hole, single outlet (fixed) combination tap assemblies (chromium plated brass), incorporating quarter turn ceramic disc headwork with single lever operating members and a lockable manual diverter to shower outlet. The spout outlet incorporates a plastic flow straightener. The product is supplied with hose, handset and metal backnuts. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.
Wall mounted three-hole, single outlet (fixed) combination tap assembly with a brass body (chrome plated) incorporating a quarter turn ceramic disc headwork with single lever operating members. The spout outlets incorporate a plastic aerator. Maximum working pressure 8.0 bar. Maximum operating temperature 60°C.
A range of three hole, single outlet (fixed) combination tap assemblies with brass bodies (chromium plated), incorporating quarter turn ceramic disc headworks and various operating members (see models). The side valves and the spout are connection via stainless steel braided EDPM lined flexible hose assemblies incorporating ½” BSP captive nut end connections. Inlet to the main body incorporates a flow regulator. The products are supplied with metal back nuts and pop-up wastes. Maximum working pressure 5.5 bar. Maximum working temperature 60°C.
Range of three-hole, single outlet (fixed) combination tap assemblies (chrome plated brass). Incorporating a quarter turn ceramic disc headwork, and dome type operating members (model RAKPER3011C) or cubed type operating members (model RAKPES3011C). Supplied with stainless steel braided EPDM lined hoses, intended for connection between the valves and the spout assembly The spout outlet incorporates a plastic aerator. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.
Range of wall mounted four-hole, single outlet, fixed, bath shower mixers (chromium plated brass) incorporating a ceramic disc diverter headwork controlling the flow to 2 outlets. The temperature is controlled independently via a thermostatic cartridge with a manual override button. The RAKPES3306C model has cube type operating members and the RAKPER3306C model has dome type operating members. The spout outlet incorporates a plastic aerator. Maximum working pressure 5.0 Bar. Maximum operating temperature 60°C.
Range of five-hole, single outlet (fixed) combination tap assemblies with brass bodies (chrome plated) incorporating quarter turn ceramic disc headworks with cross top operating members for model (ELW-135) all other models have single lever operating members and a manual diverter to shower outlet. The product is supplied with stainless steel braided EPDM lined flexible hose assemblies to connect between the side valves and spouts. Spout outlet incorporates a plastic flow straightener Product is supplied with a shower hose and handset. Maximum working pressure 5.0 bar. Maximum operating temperature 65°C.
Range of combined bath fillers and overflow waste assemblies (plated brass covers and plastic hoses) with pop-up wastes. Maximum operating temperature 65ºC. Open outlet use only.
Range of basin spout outlets with brass bodies (various finishes), the outlet incorporates either a metal aerators, plastic aerators or open outlet (depending on model). Maximum working pressure 3.5 bar. Maximum operating temperature 60°C
Range of wall mounted spout outlets with either stainless steel or brass bodies (various finishes - see model), incorporating a plastic aerator and EPDM ‘O’-rings. Maximum working temperature 60°C.
Range of spout outlets (chromium plated) brass bodies. Model 13 800 782 incorporates a plastic aerator. Maximum operating temperature 60°C
Range of wall mounted spout outlets with a chromium plated brass bodies and NBR ‘O’-rings. The outlets incorporate a plastic aerator. Maximum operating temperature 85°C.
Range of expansion vessels with EPDM membrane and stainless steel flange connections. Maximum working pressure of 10.0 bar. Maximum operating temperature 100°C.
Filling loop assemblies consisting of a brass bodied spherical valve, stainless steel braided EPDM lined flexible hose (051603F-BAGR4 model) or copper pipe (0516-ATAGBAG model) and a combined double check valve assembly incorporating a spherical valve with a DZR brass body, verified by test (suitable for backflow protection against Fluid Category 3). Maximum working pressure 10.0 bar. Maximum operating temperature 60°C
Filling loop assemblies comprising of a stainless steel braided, EPDM lined hose, double check valve assembly with isolation valve verified by test (suitable for backflow protection against fluid category 3) and either a straight or tee isolation valve. Maximum working pressure 10.0 bar. Maximum operating temperature 85ºC.
>B< Range of copper push-fit fittings for use with copper tube manufactured to EN 10226-1. Maximum working pressure 16.0 bar. Maximum operating temperature 85°C.
‘Unidelta Deltapress’ range of brass press-fit fittings for use with ‘Unidelta Flexall’ PE-RT/AL/PE-RT pipe. Maximum working pressure 10.0 bar. Maximum operating temperature 95°C.
Range of brass, chrome plated brass or DZR brass compression fittings for use with copper pipe only. Maximum working pressure 16.0 bar. Maximum operating temperature 85°C.
Range of PVC-u solvent weld and threaded union fittings incorporating an EPDM ‘O’-ring. For use with PVC-u pipe manufactured to ISO 1452 and DIN 8063. Maximum working pressure 10.0 bar. Cold water use only.
‘Xpress’ range of press fit fittings with copper or brass bodies and EPDM ‘O’-rings. For use with copper tube manufactured to EN1057. For above ground ground use only. Maximum working pressure 16.0 bar. Maximum operating temperature 100°C.
‘Endex’ range of copper alloy and copper end feed fittings for use with copper pipe. For above ground use only. Maximum working pressure 16.0 bar. Maximum operating temperature 99°C.
Center Brand range of brass and copper end feed fittings for use with copper pipe. For above ground use only. Maximum working pressure 16.0 bar. Maximum operating temperature 99°C.
Single low-level horizontal mount float switch with stainless-steel body and float. Maximum operating temperature 100°C.
Range of WC pressure flushing valves with a solenoid valve controlling the flow. The valves are operated via an infra-red sensor or push-button assembly. The solenoid valve also incorporates a lever operated isolation valve. Maximum working pressure – 5.0 Bar. Cold water use only
Range of stainless-steel plate heat exchangers with EPDM gaskets. The primary circuit, (excluding the E2 prefix models), incorporates a drain valve and a pump (excluding STP prefix models including an ‘N’ as the 14th figure). Operating parameters: Maximum working pressure of the secondary circuit: 6.0 bar or 10.0 bar (see model). Maximum working pressure of the primary circuit: E4 models: 6.0 bar. C3, E3, E2, i2: 10.0 bar. Models added February 2023 – Econoplate STP3, STC3, STP2, STC2 & STP4: 10.0 bar. Maximum operating temperature: Primary 140°C & Secondary 85°C.
Domestic hot water heat recovery unit incorporating a stainless-steel plate heat exchanger and cylinder. Maximum working pressure 3.0 bar. Maximum operating temperature 60°C.
Range of under-sink, electrically heated vented water heaters (cased and insulated). Maximum operating temperature 98˚C
Greenstar Heatslave II range of floor standing oil-fired condensing combination boilers providing domestic hot water via a plate heat exchanger and pressurised central heating system, which incorporates an expansion vessel and pressure relief valve set at 3.0 bar. The cold water inlet incorporates a screwdriver operated spherical valve followed by a plastic flow regulator inserted within the pipework. Maximum working pressure: Primary circuit 2.5 bar. Secondary circuit 10.0 bar. Maximum operating temperature 82°C.
"Greenstar" range of indirect heat interface units and "Flow 8000" (added December 2024) range of direct heat interface units providing heating and instantaneous hot water. The heating system incorporates an expansion vessel. The products are sold with or without a prefix kit (see model), which comprises of a mounting bracket that includes spherical valves for all circuits. The "Greenstar" indirect models include a pressure relief valve (set at 3.0 bar) on the space (central) heating circuit. Greenstar models: Maximum working pressure district heating 10.0 bar. Maximum working pressure space heating 2.5 bar. Maximum working pressure secondary hot water 10.0 bar. Maximum operating temperature 60°C (secondary) and 90°C (primary). Flow 8000 models (added December 2024): Maximum working pressure district and space heating 10.0 bar. Maximum working pressure secondary hot water 10.0 bar. Maximum operating temperature 60°C (secondary) and 90°C (primary).
Range of in-line water meters with brass bodies and plastic inlet filters. Maximum working pressure 16.0 bar. Maximum operating temperature 50°C (SJ & ELECTO-SJ models) Maximum operating temperature 30°C (AP VARIO and AP RADIO models)
Water meter with a DZR brass body, stainless steel temperature sensors and EPDM ‘O’-rings. The inlet incorporates a plastic strainer. Maximum working pressure 16.0 bar. Maximum operating temperature 85°C.
Range of water meter manifolds (plastic body). Model WB31520CG incorporates a single check valve cartridge and model WB31520CGDCV two single check valve cartridges, however, the complete product has not been fully tested to demonstrate it provides backflow protection Maximum working pressure 16.0 bar. Cold water use only.
‘EVE Whole house’ twin impeller booster pump with a plastic body and impellers and EPDM ‘O’-rings. The inlet and outlet hoses incorporate a screwdriver operated isolation valve. The pump body outlets incorporate a non-return valve. The product is supplied with two loose combined EPDM and stainless steel inlet washers and two loose EPDM outlet washers. Maximum working pressure 3.0 bar. Maximum operating temperature 65°C.
‘ECOCIRC XL N’ & ‘ECOCIRC XL PLUS N’ range of circulation pumps with stainless steel bodies, plastic impellers, and EPDM ‘O’-rings. Maximum working pressure 10.0 bar. Maximum operating temperature 85°C.
Range of vertical multistage pumps with stainless-steel bodies, stainless-steel impellers, shaft and outer sleeve. Maximum working pressures: T (oval flange): 16.0 bar. V (Victaullic & grooved), C (clamp flanges) & F (round flange) versions: 26.0 bar. Maximum operating temperature 100°C.
Range of multistage pumps with brass suction and discharge bodies, stainless steel housing, shaft and impeller, and EPDM ‘O’-rings and seals. Maximum working pressure: 6.0 bar (41491 & 41492 models) or 9.0 bar (41493 & 41494 models). Maximum operating temperature 65°C.
Wall mounted shower head and arm (chromium plated brass) incorporating a NBR seal and TPE gasket. The inlet to the shower head from the shower arm incorporates a stainless-steel strainer and an approved check valve cartridge, however, the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum working temperature 60°C.
Range of shower handsets and shower kits. Shower kits 2.1703.391, 2.1703.015 & 2.1703.016 incorporate a shower handset, shower hose and riser rail. Shower handset inlets incorporate a flow regulator. Maximum operating temperature 60°C.
Range of shower outlets incorporating brass bodies (various finishes) and NBR ‘O’-rings. Maximum operating temperature 85°C.
Range of shower outlets and shower kits. Shower outlets consisting of wall and ceiling mounted shower heads and hand shower. The inlets incorporate stainless steel flow regulators and approved check valve cartridges, however, the complete product has not been fully tested to demonstrate it provides backflow protection. The shower kits can consist of shower hose, shower handset, riser rail and wall outlet elbow with bracket (depending on model). Shower handset inlet incorporates a stainless-steel strainer. Both the outlet of the wall elbow and inlet of shower handset incorporates an approved check valve cartridge, however, the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum operating temperature 60°C.
Range of filter type fixed ‘shower’ outlets and shower handsets with plastic bodies. Maximum operating temperature 45°C.
Range of filter type fixed ‘shower’ outlets and shower handsets with plastic bodies. Maximum operating temperature 45°C.
Range of shower outlets incorporating brass bodies (various finishes) and NBR ‘O’-rings. Maximum operating temperature 85°C.
Shower outlet incorporating brass body (gold effect finish), incorporating a flow regulator and EPDM O-rings. Maximum operating temperature 60ºC.
Shower head with a brass body (various finishes), incorporating EPDM O- rings and a stainless-steel strainer at the inlet. Maximum operating temperature 60.0°C
Shower handset incorporating a chrome plated plastic body and EPDM ‘O’-rings. Maximum operating temperature 60°C.
Range of Y type strainers with blue epoxy coated ductile iron bodies and EPDM ‘O’-rings. Maximum working pressure 25.0 bar. Maximum operating temperature 85°C
Range of in-line `Y` patterned strainers with bronze bodies and stainless-steel strainer. Maximum working pressure 16.0 bar. Maximum operating temperature 100°C. Closed circuit up to 110°C
Range of pillar taps with brass bodies (various finishes) incorporating non-rising spindle headworks using either dome type or cross top operating members. Spout outlets incorporate plastic flow straighteners. The products are also supplied with metal back nuts. Maximum working pressure 10.0 Bar. Maximum operating temperature 85°C.
Range of deck mounted self-closing pillar taps (chromium plated brass), incorporating a spring-loaded headwork with a dome type operating member. The spout outlet incorporates a plastic flow straightener. During January and February 2022, the products are supplied with metal back nuts. From March 2022, the products are supplied with plastic backnuts. Maximum working pressure 10.0 bar. Maximum working temperature 60°C.
Range of TPE lined flexible shower hoses incorporating a conical nut. Maximum operating temperature 60°C.
Range of plastic shower hoses (chrome effect finish) incorporating a PVC inner liner, with EPDM ‘O’-rings and/or washers. Models H3DN6-XXX101C and H3DV2-XXX101A incorporate stainless steel strainers. Maximum operating temperature 60°C.
Range of TPE and TPS lined flexible hose assemblies incorporating NBR ‘O’-rings and various end connections. Maximum operating temperature 60°C.
Range of PET (Polyethylene terephthalate) braided flexible hoses incorporating PEX liner and EPDM ‘O’-rings. Maximum working pressure 5.0 bar. (10.0 bar for models added September 2025). Maximum operating temperature 70°C.
Range of plastic shower hoses (chrome effect finish) incorporating a PVC inner liner, with EPDM ‘O’-rings and/or washers. Maximum operating temperature 60°C.
Range of stainless steel braided HDPE lined flexible hose assemblies incorporating EPDM ‘O’-rings and/or washers depending on end connection. Maximum working pressure 10.0 bar. Maximum operating temperature 85°C
Range of stainless-steel braided EPDM lined flexible hose assemblies with various end connections. SCFA models incorporate a spherical valve. Maximum working pressure 16.0 bar. Maximum operating temperature 85°C.
A range of wall mounted self-closing shower valves (chromium plated brass), incorporating a spring loaded headwork with a dome type operating member. Model TF222CP250 is supplied with metal back nut. Maximum working pressure 10.0 bar. Maximum working temperature 60°C.
Range of thermostatic blending valves with brass bodies, EPDM ‘O’-rings and chromium plated dome type operating members. The inlets incorporate plastic strainers and approved check valve cartridges, however, the complete product has not been fully tested to demonstrate it provides backflow protection Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.
Range of wall mounted, thermostatic shower blending valves, with a brass body (various finishes - see model), incorporating a thermostatic cartridge controlling the temperature with various operating members (see model). Both inlets incorporate a combined EPDM washer with a stainless steel strainer and an approved single check valve cartridge, however, the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum working pressure 5.0 bar. Maximum operating temperature 65°C.
Wall mounted, bar type thermostatic shower mixer (chromium plated brass), incorporating a quarter turn ceramic disc headwork controlling the flow with a dome operating member. The temperature is controlled independently via a thermostatic cartridge with a dome operating member. The outlet incorporates a single check valve cartridge assembly; however, the complete product has not been fully tested to demonstrate it provides backflow protection. The inlet connections incorporate an eccentric isolation valve and flow regulator. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.
Range of wall mounted, concealed or exposed thermostatic shower valves (chromium plated brass), incorporating a single sequential headwork controlling both flow and temperature via a single lever operating member. Each inlet elbow incorporates a combined TPE washer and stainless-steel strainer. The main valve body inlets each incorporate approved check valve cartridge, however, the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum working pressure 10.0 bar. Maximum operating temperature 65°C.
Range of electronic, thermostatic mixing valves which incorporate a solenoid valve on the inlet and various outlet configurations dependant on model. All models are supplied with a user interface that controls flow and temperature. The inlets of models 1.1503.678, 1.1503.682, 1.1503.690, 1.1503.698 & 1.1621.099 incorporate a single check valve cartridge, however, the complete product has not been fully tested to demonstrate it provides backflow protection Model 1.1503.702 – Rada Sense W KIT T3 Washbasin is supplied with a wall mounted spout outlet. Model 1.1503.706 – Rada Sense S KIT T3 Shower is supplied with a fixed shower outlet. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C
Range of wall mounted thermostatic bar shower valves incorporating a thermostatic cartridge controlling the temperature with a dome operating member incorporating a manual override button. The flow to the handset or overhead shower is via a ceramic disc headwork with a dome operating member. Inlets Incorporate approved check valve cartridges, however, the complete product has not been fully tested to demonstrate it provides backflow protection. RRK models are also supplied with shower hose, handset, overhead shower head and riser rail. Maximum working pressure 5.0 bar. Maximum operating temperature 65ºC.
A range of wall mounted thermostatic blending valves with brass bodies (various finishes). The temperature is controlled via a thermostatic cartridge and dome operating member and flow is controlled via a quarter turn ceramic headwork. Product can come with one, two or three push type cartridges that divert the flow to various outlets (see model) The inlets incorporate approved check valve cartridges however, the complete product has not been fully tested to demonstrate it provides backflow protection Maximum working pressure 10.0 bar. Maximum working temperature 60°C.
Range of concealed thermostatic shower valves with brass bodies incorporating a quarter turn ceramic disc headwork controlling the flow to the shower outlet model VQ20 incorporates a single shower outlet (x1 headwork) and model VQ21 incorporates a double shower outlet (x2 headworks). The temperature is controlled independently via a thermostatic cartridge. Both inlets incorporate approved single check valve cartridges, however, the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum working pressure 10.0 bar. Maximum operating temperature 65°C.
Range of wall mounted bar type thermostatic shower mixers with brass bodies (various finishes), incorporating a ceramic disc headwork which controls and diverts the flow to a hand shower or overhead shower using a dome type operating member. The temperature is controlled independently via a thermostatic cartridge with a dome type operating member with a manual override button. Both inlets incorporate a stainless-steel strainer and an approved check valve cartridges, however, the complete product has not been fully tested to demonstrate it provides backflow protection. Products are supplied with an overhead shower, shower hose and shower handset. Maximum working pressure: 5.0 Bar. Maximum operating temperature: 60ºC.
Range of T type thermostatic blending valves with (nickel plated) DZR brass bodies. The inlets incorporate a stainless-steel strainer and single check valve cartridge verified by test (suitable for backflow protection against Fluid Category 2) Models HEAT160030 & HEAT160035 also incorporate a servicing valve at the inlet. Maximum working pressure 5.0 bar. Maximum operating temperature 85°C
Concealed electronic thermostatic shower valve with a plastic body, the flow is controlled via two motorised valves for hot and cold supply. Both inlets incorporate a plastic strainer and an approved check valve cartridge; however, the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum working pressure 7 bar. Maximum working temperature 65°C.
Range of wall mounted concealed thermostatic shower valves (brass body) incorporating a quarter turn ceramic disc headworks controlling the flow with a range of single lever, dome or hand wheel operating members. The temperature is controlled independently via a thermostatic cartridge. Both inlets incorporate stainless-steel strainers and approved check valve cartridges, however, the complete product has not been fully tested to demonstrate it provides backflow protection. Model are available in various configurations, please see model. Maximum working pressure 5.0 bar. Maximum operating temperature 65°C.
Range of handwheel & gear operated butterfly valves with blue epoxy coated ductile iron bodies and discs and EPDM rubber seat. Maximum working pressure 16.0 bar. Cold water use only. Maximum operating temperature 85°C (from Sept 2021)
Ceramic disc diverter cartridge with on/off function incorporating a plastic body, NBR ‘O’-rings and silicone seals. For insertion into specifically dimensioned bores. Maximum working pressure 10.0 bar. Maximum operating temperature 95°C.
Manual diverter valve controlling the flow to a hand shower or overhead shower, housed within a brass body (various finishes). Incorporating a stainless-steel strainer and approved check valve cartridge on the inlet, however, the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum operating temperature 70°C.
Single inlet, flow control valve with a brass body, incorporating a ‘detent’ (push to on push to off) headwork controlling the flow. The product is supplied with a trim sets in various finishes (see model) Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.
Range of pressure reducing valves with DZR brass bodies. The capillary union and compression models are for use with copper pipe (manufactured to BSEN 1057). The inlets incorporate a stainless strainer. Reliance 315i Commercial Pressure Reducing Valves: Maximum supply pressure 21.0-25.0 bar - outlet adjustment range: 2.5 bar min. outlet pressure, 6.0 bar maximum outlet pressure. Maximum supply pressure 16.0-20.0 bar - outlet adjustment range: 2.0 bar min. outlet pressure, 6.0 bar maximum outlet pressure. Maximum supply pressure 11.0-15.0 bar - outlet adjustment range: 1.5 bar min. outlet pressure, 6.0 bar maximum outlet pressure. During January 2022 these products were for cold water use only. Between February 2022 and January 2027 the products are for use with water up to 65°C. Models added May 2025: Maximum supply pressure 25.0 Bar. Outlet adjustment range: 5.0 bar min, 10.0 bar maximum outlet pressure. Maximum operating temperature 65°C.
‘Easiset 320 series’ adjustable (in-line) pressure reducing valves with DZR brass bodies. Compression and pushfit models are for use with copper pipe (manufactured to BS EN 1057:2006+A1:2010). From March 2022 the pushfit models can also be used with PB pipe (manufactured to BS EN 7291-2:2010) and PEX pipe (manufactured to BS EN 7291-3:2010). Maximum inlet supply pressure: 16.0 bar all models with copper pipe. From March 2022: SBPRED320001 & SBPRED320005 models: 12.0 bar with PEX & PB pipe. SBPRED320050 & SBPRED320055 models: 6.0 bar with PEX & PB pipe. Maximum outlet pressure 1.5 bar to 5.5 bar. Maximum operating temperature: COLD WATER EASISET 320 SERIES: 45°C with copper pipe, and from March 2022: cold water use only with PEX & PB pipe. HOT WATER EASISET 320 SERIES: 80°C with copper pipe, and from March 2022: 80°C with PEX & PB pipe.
Range of in-line manually adjustable pressure reducing valves with blue epoxy coated cast iron bodies, stainless steel cartridges, EPDM diaphragm and seals. Adjustable outlet pressures in the range of: D15S-50A - DS15S-100A = 1.5 to 7.5 bar. D15S-150A - DS15S-200A = 1.5 to 8.0 bar. Models added April 2023: D15SN-50A - DS15SN-100A = 0.5 to 2.0 bar. Maximum supply pressure 16.0 bar. D15S-150A and D15S-200A models: Cold water use only. All other models have non-metallic material suitable for up to 60°C.
Range of adjustable, pilot operated, pressure reducing control valves with black plastic bodies, EPDM diaphragm, EPDM ‘O’-rings and NBR seals. The products are supplied with auxiliary stainless-steel tubing, lever operated spherical valves, integral stainless-steel strainer, pilot valve and a quarter turn ceramic disc valve. Maximum inlet supply pressure 16.0 bar. Maximum outlet pressure 0 - 8.5 bar, 7.0 - 13.5 bar or 12.0 - 16.0 bar (see model). Maximum operating temperature 60°C.
Pressure relief valve pre-set at 6.0 bar, with a brass body and EPDM seat washer. Maximum operating temperature 115°C.
Range of pressure relief valves pre-set at 3.0 bar with brass bodies and a EPDM membrane. Valve incorporates a manually operated easing gear. Maximum operating temperature 85°C.
Solenoid valve with a plastic body, EPDM membrane and plastic or stainless steel strainer. From March 2023 the product may also be supplied with a Ø 28.61mm x ¾” BSP (M) plastic adaptor. From December 2023 the product may also be supplied with a plastic filter. Maximum working pressure 10.0 bar. Maximum operating temperature 70°C.
Non-metallic materials and components comply with BS6920 at 70°C
Range of solenoid valves with a plastic body and an EPDM diaphragm. Available as either inline (126 suffix models) or 90° outlet (115 suffix models). The inlet of the existing 62.009.115 (¾” BSP (M) inlet x ⅜” BSP (M) outlet) model incorporates a plastic strainer and a plastic flow regulator. The products are also supplied with an optional stainless-steel strainer for installation on the inlet. Maximum working pressure 10.0 bar. Maximum operating temperatures: Existing model 62.009.115: ¾” BSP (M) inlet x ⅜” BSP (M) outlet: 90°C. Models added November 2023: Cold water use only. From March 2025 all models: 90°C.
A range of screwdriver operated spherical valves with brass bodies and brass ball, EDPM ‘O’-rings and fibre washers. Maximum working pressure 16.0 bar, Maximum working temperature 85°C.
Range of inline and angled screwdriver or lever handle operated spherical valves with (chromium plated) brass bodies, chromium plated brass ball, NBR ‘O’-rings. For use with copper pipe manufactured to EN 1057 Maximum working pressure 16.0 bar at 30°C and 5 bar at 99°C Maximum working pressure 6.0 bar. Maximum operating temperature 90°C (model TX480 only)
Range of ‘T’-handle, spherical vales with PVC-u bodies, EPDM ‘O’-rings and either a TPE seat seal (UCB01 model) or PTFE seat seal (all other models). For use with PVC-u pipe manufactured to ISO 1452 and DIN 8063. Maximum working pressure 10.0 bar. Cold water use only.
Range of gate valves with a DZR brass body and disc, and PTFE washers. The products are operated by a non-rising spindle headwork with a hand wheel operating member. For use with copper pipe manufactured to EN1057. Maximum working pressure 16.0 bar. Maximum operating temperature 85°C.
Range of gate valves with blue epoxy coated ductile iron bodies and EPDM coated ductile iron wedges. The valves are operated via a non-rising spindle with a hand wheel operating member. Maximum working pressure 16.0 bar. Maximum operating temperature 85°C.
Range of lock shield or handwheel operated gate valves with brass bodies, gate & PTFE seals, for use with copper tube manufactured to EN1057. Maximum working pressure 16.0 bar. Maximum operating temperature 85°C.
Range of regulating valves with blue epoxy coated ductile iron bodies incorporating EPDM gaskets and hand wheel operating member. Maximum working pressure 25.0 bar. Maximum operating temperature 85°C.
‘Tornado’ & ‘Ninjo’ ranges of freestanding and undercounter bedpan washers with flow controlled via a solenoid and discharged via type `AB` airgap (verified by test - suitable for backflow protection against fluid category 5). Maximum working pressure 8.0 bar. Maximum operating temperature 60°C
Range of commercial front loading washing machines with flow controlled by solenoid valve and discharged via a type AD air gap arrangement (verified by test - suitable for backflow protection against fluid category 5). The product is supplied with a single check valve assembly (suitable for backflow protection against Fluid Category 2) and PEX lined rubber inlet connections hoses. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C
Range of commercial front loading washing machines with flow controlled by solenoid valve and discharged via a type AD air gap arrangement (verified by test - suitable for backflow protection against fluid category 5). The product is supplied with a single check valve assembly (suitable for backflow protection against Fluid Category 2) and PEX lined rubber inlet connections hoses. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C
Range of UV disinfection units incorporating 316L stainless steel bodies and quartz sleeves. Maximum working pressure 10.0 bar. Maximum operating temperature 35°C.
'Jerlac Two-Pack Epoxy Blue – 746 & Jerlac Two-Pack Epoxy Red – 747'. Factory applied, blue or red coloured, two-component epoxy coatings. Mix resin and hardener in a 3:1 volume ratio and apply as per manufacturer's instructions. Cure for 7 days@30°C. For use with water up to 60°C. This material is only approved for the mixing and curing conditions that appear on the approval. If the mixing and/or curing conditions are varied from those specified on the approval then the material is not covered by the scope of the approval.
`3M™ Scotchkote™ Fusion-Bonded Epoxy Coating 134`. Factory applied, green coloured, epoxy coating. Pre-heat substrate to 232°C, before dip coating as per manufacturer’s data sheet and application guide ‘78-8141-8528-2 Rev A’ dated February 2016, for 3 seconds. Cure for 10 minutes at 232°C. For use with water up to 23°C. This material is only approved for the application and curing conditions that appear on the approval. If the application and/or cure conditions are varied from those specified on the approval then the material is not covered by the scope of the approval.
Resicoat factory applied, epoxy powder coatings. The coatings are electrostatically applied by spray onto a panel pre-heated for 15 minutes@225°C and then post cured for 15 minutes@220°C. For use with water up to 85°C. The following grades are manufactured at GERMANY, REUTLINGEN: Resicoat R4 blue: R4-ES HJ601R, R4-ES HJ605R, R4-ES HJ606R, R4-FB HJC04R, R4-FB HJC06R, R4-FB HJC08R, R4-FB HJC12R, R4-FB HJC33R, R4-FB HJC34R, R4-FB HJC36R, R4-ES HJF01R, R4-ES HJF09R, R4-ES HJF10R, R4-ES HJF13R PAM blue, R4-ES HJF14R, R4-ES HJF22R, R4-ES HJF23R, R4-ES HJF24R, R4-ES HJF26R, R4-ES HJF42R, R4-ES HJG05R, R4-ES HJG07R, R4-ES HJG08R, R4-ES HJH01R & R4-FB HJC26R. Resicoat R4 red/red-brown: R4-FB HGC07R, R4-FB HGC17R, R4-ES HGF03R, R4-ES HGF04R, R4-ES HGF10R, R4-ES HGF17R, R4-ES HGF20R, R4-ES HGH02R. Resicoat R4 black: R4-ES HNF04R & R4-FB HNC01R. Resicoat R4 green: R4-FB HKC71R. Resicoat R8 blue: R8-ES HJF97R, R8-FB HJC37R, R8-FB HJC38R, R8-ES HJG13R, R8-FB HJC50R, R8-FB HJC51R, R8-FB HJC52R, R8-FB HJC53R, R8-FB HJC54R, R8-ES HJF1KR, R8-ES HJF2KR, R8-ES HJF3KR, R8-ES HJF4KR, R8-ES HJF5KR, R8-ES HJF6KR, R8-ES HJG29R & R8-ES HJ609R. Resicoat R8 blue grades added in July 2024: R8-FB HJC55R, R8-ES HJF4MR & R8-ES HJF5LR. Resicoat R8 red/red-brown: R8-FB HGC12R, R8-ES HGF66R, R8-ES HGF67R & R8-ES HGF68R. Resicoat R8 red added in February 2025: R8-ES HGF65R. Resicoat R8 black: R8-ES HNC03R & R8-ES HNF43R. Resicoat R2 blue: R2-ES HJF5BR & R2-ES HJF4ER. The following grades are manufactured at USA, NASHVILLE: Resicoat R4 blue: R4-ES HJ606R, R4-ES HJF10R, R4-ES HJF24R & R4-ES HJF42R. Resicoat R4 red/red-brown: R4-FB HGC17R & R4-ES HGF17R. Resicoat R4 green: R4-ES HKF47R. The following grades are manufactured at CHANGZHOU, CHINA: Resicoat R2 blue: R2-ES HJF5BR. Resicoat R4 blue: R4-FB HJC03R, R4-FB HJC06R, R4-FB HJC08R, R4-FB HJC15R, R4-FB HJC23R, R4-FB HJC29R, R4-ES HJF01R, R4-ES HJF10R, R4-ES HJF13R, R4-ES HJF14R, R4-ES HJF22R, R4-ES HJF24R & R4-ES HJF42R. Resicoat R4 red/red-brown: R4-ES HGF03R, R4-ES HGF04R & R4-ES HGF17R. Resicoat R4 black: R4-ES HNF04R. Resicoat R8 blue grades added in February 2025: R8-FB HJC50R, R8-ES HJF3KR, R8-ES HJF97R The following grades are manufactured at IZMIR, TURKEY: Resicoat R2 blue: R2-ES HJF3D4 & R2-ES HJF4D4. Resicoat R4 blue: R4-ES HJF1C4 & R4-ES HJF2C4. Resicoat R8 blue added in February 2025: R8-ES HJF5M4 The following grades are manufactured at THANE, INDIA: Resicoat R2 blue: R2 HJC43N, R2 HJF2HN, R2 HJF5BR. These materials are only approved for the curing conditions that appear on the approval. If the cure conditions are varied from those specified on the approval then the materials are not covered by the scope of the approval.
'Polyurea FA 1044'. Factory applied, two-component, beige coloured polyurea coating. Mix parts A and B in a 1:1 volume ratio apply as per manufacturer's TDS '07/2015 Rev.00'. Cure for 96 hours@25°C. For use with water up to 23°C. This material is only approved for the mixing and curing conditions that appear on the approval. If the mixing and/or curing conditions are varied from those specified on the approval then the material is not covered by the scope of the approval.
Resicoat factory applied, epoxy powder coatings. The coatings are electrostatically applied by spray onto a panel pre-heated for 15 minutes@225°C and then post cured for 15 minutes@220°C. For use with water up to 85°C. Resicoat R4 blue R4-FB HJC06R & R4-ES HJF26R. Resicoat R4 red/red-brown R4-ES HGF03R. Resicoat R4 black R4-FB HNC01R. Resicoat R4 black: R4-ES HNF04R.
‘PVEF undercoat with Fluiglide Topcoat’. Factory applied, cream coloured (once mixed and applied), coating system comprising of ‘Polyglass VEF’, two-component glassflake vinyl ester undercoat and ‘Fluiglide’, two-component polyester topcoat. Mix and apply ‘Polyglass VEF’ in accordance with Corrocoat ‘product reference 2/23’ dated ‘5th June 2007’ and last reviewed ‘March 2022’. Cure for 24 hrs@20°C (±1°C). Mix and apply ‘Fluiglide’ in accordance with Corrocoat ‘product reference ‘4/01’, valid from ‘23rd October 1995’ and last reviewed ‘March 2022’. Cure for a minimum of 6 days@20°C (with a lower tolerance of -1°C). These materials are only approved for the curing conditions that appear on the approval. If the cure conditions are varied from those specified on the approval then the materials are not covered by the scope of the approval.
'SG100'. Off-white coloured (opaque) silicone grease. Apply as per manufacturer's instructions. For use with water up to 65°C.
'SIL500'. Off-white coloured (opaque) silicone grease. Apply as per manufacturer's instructions. For use with water up to 65°C.
'Zytel® RSFG30G50L BK595'. Black coloured, injection moulded glass fibre reinforced nylon (polyamide 610) material. For use with water up to 85°C.
'Tecomid NB40 GR30 NL HC QW'. Off-white coloured (translucent), injection moulded PA6 material. For use with water up to 85°C.
'4MID 9B22130 W-A BNL100'. Off-white coloured (translucent), injection moulded PA6 material. For use with water up to 85°C.
'Akoalit PB 4268 White & Akoalit PB 4267 Grey'. White or grey coloured, extruded polybutylene material. For use with water up to 85°C.
'DBS0420-DBS0640'. Orange coloured HDPE ball float, manufactured by blow moulding. For use with water up to 23°C.
'CPI Electrofusion fittings'. Black coloured, injection moulded HDPE fittings. For use with water up to 65°C.
'CPI HDPE Pipes'. Black coloured (with blue external stripes), extruded HDPE pipes. For use with water up to 65°C.
‘Kingbull PE100 blue pipe (391721)'. Blue coloured, extruded polyethylene pipe. ‘Kingbull PE100 black pipe’ (0103102). Black coloured (with external blue stripe), extruded polyethylene pipe. Both for use with water up to 65°C.
'LSPE-BE001 PE Pipe (Blue)'. Blue coloured, extruded polyethylene pipe. For use with water up to 60°C.
'Georg Fischer HDPE PE100 Black Machined Fabricated Fittings and Segmented Fabricated Fittings'. Black coloured, HDPE PE100, machined fabricated fittings. Black coloured, with or without blue stripe, extruded and fabricated, HDPE PE100 fabricated segmented fittings. For use with water up to 60°C.
‘Kingbull PE100 blue pipe (391721)'. Blue coloured, extruded polyethylene pipe. ‘Kingbull PE100 black pipe’ (0103102). Black coloured (with external blue stripe), extruded polyethylene pipe. Both for use with water up to 65°C.
'HDPE 100 Black POLIMAXX P901BK'. Black coloured, extruded HDPE pipe. For use with water up to 65°C.
'HDPE 100 Blue POLIMAXX P901BL'. Blue coloured, extruded HDPE pipe. For use with water up to 65°C.
WOTLON MPPO 1000-GF2 BK006. WOTLON MPPO 1000-GF2 GY003. WOTLON MPPO 1000-GF2 NC001. WOTLON MPPO 1000-GF3 BK006 WOTLON MPPO 1000-GF3 GY003 WOTLON MPPO 1000-GF3 NC001 Natural (NC grades - appears beige in colour), black coloured (BK grades) and grey coloured (GY grades), injection moulded MPPO materials. For use with water up to 85°C.
'Rainson PP IOCL 3030MG Blue & Rainson PP IOCL 3030MG Black'. Injection moulded polypropylene materials. 'Rainson PP IOCL 3030MG Blue' is for use with water up to 23°C. 'Rainson PP IOCL 3030MG Black' is for use with water up to 65°C.
'AKORROS® B208A'. Brown coloured, extruded hard rubber Shore hardness 78. Tested in-radius size 1.11mm. For use with water up to 60°C.
'LOPI80 'O'-rings'. Black coloured, injection moulded EPDM 'O' rings. Shore hardness 80. Tested in-radius size 2.26mm. For use with water up to 85°C.
'LOPI80 'O'-rings'. Black coloured, injection moulded EPDM 'O' rings. Shore hardness 80. Tested in-radius size 2.26mm. For use with water up to 85°C.
'9711/2 Black'. Black coloured, compression moulded EPDM 'O' rings. Shore hardness 75. Tested in-radii sizes between 0.88mm & 2.85mm. Between October 2021 and July 2022, the components were for use with water up to 23°C. Between August 2022 and October 2026, the components are for use with water up to 85°C.
'EWDRI 50, EWDRI 55, EWDRI 60, EWDRI 65, EWDRI 70 & EWDRI 80'. Black coloured, compression moulded EPDM rubber materials. Shore hardness between 50 & 80. Tested in-radius size 0.69mm. 'EWDRI 50' is for use with water up to 70°C. 'EWDRI 55, EWDRI 60, EWDRI 65, EWDRI 70 & EWDRI 80' are for use with water up to 60°C.
'CHEMILINE AH001 FB 026'. Black coloured, niltrile rubber material manufactured by calendaring and curing. Shore hardness 70A. Tested in-radius size 1.1mm. For use with water up to 65°C.
‘NGP 60 T (Translucent – off-white), NGP 60 T/R (Transy Red), NGP 60 BK (Black), NGP 60 GY (Grey) & NGP 60 W (White)’. Extruded, platinum cured, silicone rubber tubing. Shore hardness 60. Tested in-radii sizes between 0.75mm & 1.5mm. For use with water up to 85°C
‘Silopren LSR 2030, 2040, 2050, 2060, 2070 & 2080’. Natural (appears clear), compression moulded silicone rubbers with a shore hardness between 30 and 80. Tested in-radius size 1.0mm. For use with water up to 85°C.
Range of wall mounted, single hole, single outlet (fixed) electronically controlled tap assemblies (chromium plated brass or stainless steel bodies). The flow is controlled by a solenoid valve activated via an infra-red sensor. The spout outlets incorporate a plastic aerator. Maximum working pressure 6.0 bar. Maximum operating temperature 60°C
Range of single hole, single outlet, fixed, electronically controlled tap assemblies with brass bodies (various finishes), incorporating an electronic cartridge controlling the flow which is activated via an infrared sensor (either battery or mains powered). Models 31 171 xxx & 31 173 xxx incorporates a manually operated temperature control. The inlet adapters incorporate stainless steel filters and single check valve cartridges verified by test (suitable for backflow protection against Fluid Category 2 ). The spout outlets incorporate a plastic aerator. Maximum working pressure 8.0 bar. Maximum operating temperature 60°C.
Concealed WC dual flushing cistern with a BS 1212-4 (2016) float operated inlet valve providing a Type AG air gap arrangement and a dual flush pneumatic outlet valve. The flush volume is operated by a two-push button assembly for a 6 or 3 litre flush volume. Maximum working pressure 10.0 bar. Cold water use only.
Concealed WC dual flushing cistern with a BS 1212-4 (2016) float operated inlet valve providing a Type AG air gap arrangement and a dual flush outlet valve. The flush volume is operated by a two push button assembly for a 6 or 3 litre flush volume. Incorporating a servicing valve on the inlet supply. Maximum working pressure 10.0 bar. Cold water use only.
Range of check valve cartridges with plastic bodies to be housed in specifically dimensioned bores. Maximum working pressure 16.0 bar. Maximum operating temperature 65°C
Double check valve assembly consisting of two spring loaded resilient trim in-line check valve cartridges housed in a DZR brass body. For use with copper pipe manufactured to EN1057. Maximum working pressure 16.0 bar. Maximum operating temperature 85°C.
Range of wall mounted, electrically heated catering water boilers. The boilers incorporate stainless steel storage tanks with stainless steel vent and overflow and silicon washers and gaskets, fed via a solenoid valve. The water is discharged via a self-closing tap with single lever operating member. The solenoid valve incorporates a plastic strainer at the inlet. Maximum working pressure 7.0 bar. Maximum operating temperature 98°C.
Range of single hole, single outlet (fixed) over the rim (swivel nozzle) bidet combination tap assemblies with brass bodies (various finishes), incorporating a ceramic cartridge headworks and a single lever operating member. The spout outlet incorporates a plastic aerator. The product is supplied with a pop-up waste. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.
Range of ceramic cartridge headworks with plastic bodies and EPDM ‘O’-rings, for insertion into specifically dimensioned bores. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.
Range of ceramic disc and non-rising spindle headworks headworks incorporating brass bodies and NBR ‘O’-rings. For insertion into any specifically dimensioned bores. Maximum working pressure 16.0 bar. Maximum operating temperature 85°C.
Range of ceramic cartridge headworks with plastic bodies and EPDM rubber ‘O’-rings for insertion into specifically dimensioned bores. Maximum working pressure 16.0 bar. Maximum operating temperature 85°C.
Ceramic disc 2-way diverter headworks with plastic bodies to be inserted into specifically dimensioned bores. Maximum working pressure 25.0 bar. Maximum operating temperature 65°C.
Range of ceramic cartridge headworks with plastic bodies and silicone seals for insertion into specifically dimensioned bores. Maximum working pressure 10 bar. Maximum operating temperature 85°C. (Model: 35D-10DP) Maximum operating temperature 65°C.
Range of deck mounted, single hole, single outlet (fixed) electronically controlled combination tap assemblies with stainless steel bodies (in various finishes). The flow is controlled by a solenoid valve activated via an infra-red sensor. The solenoid housing attaches to the main tap body via (black) LLDPE tubing. The spout outlets incorporate a plastic aerator. Maximum working pressure 6.0 bar. Maximum operating temperature 60°C
Range of single hole, single outlet (fixed) combination tap assemblies (chromium plated brass) incorporating ceramic cartridge headworks and single lever operating members. The spout outlet incorporates a plastic aerator. A42734 & A42735 range are supplied with lever type pop-up wastes. Maximum working pressure 10.0 bar. Maximum operating temperature 60ºC.
Single hole, single outlet fixed combination tap assembly (Chrome plated brass), incorporating a ceramic cartridge headwork with a single lever operating member. The spout outlet incorporates a plastic aerator. Maximum operating pressure 10.0 bar. Maximum operating temperature 60°C
Single hole, single outlet fixed combination tap assembly (Chrome plated) brass body, incorporating a ceramic cartridge headwork with a single lever operating. The spout outlet incorporates a plastic aerator. The product is supplied with a click-type waste. Maximum operating pressure 10.0 bar. Maximum operating temperature 60°C
Single hole, single outlet fixed combination tap assembly (chrome plated brass) body, incorporating a ceramic cartridge headwork with a single lever operating member. The spout outlet incorporates a plastic aerator. Maximum operating pressure 10.0 bar. Maximum operating temperature 60°C.
Single hole, single outlet (fixed) combination tap assembly (chromium plated brass), incorporating a ceramic cartridge headwork with a single lever operating member. The spout outlet can incorporate either a plastic flow straightener or a plastic aerator. When supplied with a plastic flow straightener there is a combined EPDM washer and stainless steel strainer behind it. The products are available either as a version with a pop-up waste or one with a click type waste. Maximum working pressure 5.0 bar. Maximum operating temperature 70°C.
Range of single hole, single outlet (fixed) combination tap assemblies with brass bodies (various finishes – see model), incorporating a ceramic cartridge headwork with a single lever operating member. The spout outlet incorporate a plastic aerator. The A42722VUK model is supplied with a pop-up waste. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.
Range of single hole, single outlet fixed combination tap assemblies, incorporating brass bodies (various finishes). Model 3034-CR has a non-rising spindle headwork with cross top operating members. All other models have a ceramic cartridge headwork with single lever operating member. The spout outlets incorporate a plastic aerator. Maximum operating pressure 5.0 bar. Maximum operating temperature 60°C.
Range of single hole, single outlet fixed combination tap assemblies, incorporating brass bodies (various finishes), ceramic cartridge headwork with a single lever operating member and waterfall spout outlet. The waterfall spout outlets of models 3110-CR, 3110M-CR & 3260-CR incorporate a stainless-steel mesh. Maximum operating pressure 5.0 bar. Maximum operating temperature 60°C.
Single hole, single outlet fixed combination tap assembly with a brass body (various finishes), incorporating a ceramic cartridge headwork with a single lever operating member. The spout outlet incorporates a plastic flow straightener. The product is supplied with a lever type pop-up waste. Maximum working pressure 5.0 Bar Maximum operating temperature 65°C
Range of single hole, single outlet (swivel) combination tap assemblies with brass bodies (various finishes), incorporating a quarter turn ceramic disc headworks with single leaver operating members. The spout outlet incorporates a plastic aerator. Maximum working pressure 5.5 bar. Maximum operating temperature 60°C.
Range of single hole, single outlet (swivel) combination tap assemblies with brass bodies (various finishes), incorporating a ceramic cartridge or quarter turn ceramic disc headworks (see model) with single lever operating members. The spout outlet incorporates a flow straightener or optional aerator. Maximum working pressure 5.0 bar. Maximum operating temperature 65°C.
Range of single hole, single outlet (swivel) combination tap assemblies with brass bodies (various finishes), incorporating a ceramic cartridge headwork and a single lever operating member. The spout outlet incorporates a plastic aerator. Maximum working pressure 5.0 bar. Maximum operating temperature 85°C.
Single hole, single outlet (swivel) combination tap assemblies (chromium plated brass), incorporating quarter turn ceramic disk headworks with a single lever operating members. The spout outlet incorporates a plastic aerator. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.
Range of single hole, single outlet (swivel) combination tap assemblies (chromium plated brass) incorporating quarter turn ceramic disk headworks with single lever operating members. The spout outlet incorporates a plastic aerator. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.
Single hole, single outlet (swivel) combination tap assembly with a brass body (various finishes), incorporating a ceramic cartridge headwork with a single lever operating member. The spout outlet incorporates a plastic aerator. Maximum working pressure 5.0 bar. Maximum operating temperature 65°C.
Range of single hole, single outlet (swivel) combination tap assemblies with brass bodies (various finishes), incorporating a ceramic cartridge headwork with single lever operating members. The spout outlet incorporates a plastic aerator. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.
Single hole, single outlet (swivel) combination tap assembly incorporating a brass body (chrome plated) and ceramic cartridge headwork with single lever operating members. The spout outlet incorporates a plastic aerator. Maximum working pressure 5.0 bar. Maximum operating temperature 65°C.
Range of wall mounted, single hole, single outlet (swivel) combination tap assemblies (chromium plated brass or PVD brass finishes), incorporating a ceramic cartridge headwork with a single lever operating member. The spout outlets incorporate a plastic aerator. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C
Range of single hole, single outlet (swivel) combination tap assemblies (various finishes). Incorporating a ceramic cartridge headwork with a single lever operating member. The spout outlet incorporates a plastic aerator. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.
Range of single hole, double outlet (swivel) combination tap assemblies (chromium plated brass), incorporating a ceramic cartridge headwork with a single lever operating member. The cold water inlet hose Incorporates approved check valve cartridge(s), however, the complete product has not been fully tested to demonstrate it provides backflow protection The spout outlet incorporates a plastic aerator. Maximum working pressure 5.5 bar. Maximum operating temperature 60°C.
Single hole, double outlet (swivel) combination tap assembly (chromium plated brass), incorporating ceramic disc headworks with a single lever operating members.The spout outlet incorporates a plastic flow straightener. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.
Wall mounted, concealed, two-hole, single outlet fixed combination tap assembly (chrome plated brass) body incorporating a ceramic cartridge head work with a single lever operating member. The spout outlet incorporates a plastic aerator. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.
Wall mounted, concealed two-hole, single outlet fixed combination tap assembly (chrome plated brass) body incorporating a ceramic cartridge headwork with a single lever operating member. The spout outlet incorporates a plastic flow straightener. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.
Range of two hole, single outlet, (fixed) combination tap assemblies (chromium plated brass), incorporating a quarter turn ceramic disc headwork with single lever operating members. The spout outlets incorporate a plastic flow straightener and the products are supplied with metal backnuts. Maximum working pressure 10.0 bar. Maximum operating temperature 85°C.
Range of two hole, single outlet, (fixed) combination tap assemblies (chromium plated brass), With a quarter turn ceramic disc headwork with single lever operating members. Models M4306, M4306E & M4306F incorporate a non rising spindle headwork with dome type operating members. Model M4306G incorporate a non rising spindle headwork with cross top operating members. The spout outlets incorporate a plastic flow straightener and the products are supplied with metal backnuts. . Maximum working pressure 10.0 bar. Maximum operating temperature 85°C.
Range of two-hole, single outlet (fixed) combination tap assemblies (chromium plated brass) incorporating quarter turn ceramic disc headworks with cubed or dome operating members. The spout outlet incorporates a plastic flow straightener. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.
Wall mounted two-hole, metal, single outlet, fixed combination tap assembly (chromium plated brass), with a quarter turn ceramic disc headwork controlling the flow with a dome operating member. The temperature is controlled independently via a thermostatic cartridge with a dome operating member incorporating a manual override button. The spout incorporates a plastic flow straightener. Both inlets incorporate stainless steel strainer and an approved check valve cartridge, however, the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum operating pressure 5.0 bar. Maximum operating temperature 60° C
Range of wall mounted two-hole, metal, single outlet (fixed) combination tap assemblies (chromium plated brass), incorporating a ceramic disc diverter headwork controlling the flow between the spout outlet and the shower outlet with a dome type operating member. Temperature is controlled independently via a thermostatic cartridge with dome type operating members that incorporates a manual override button. The spout outlet incorporates a plastic aerator. Each inlet incorporates a stainless-steel strainer and an approved check valve cartridge, however, the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum working pressure 10.0 Bar Maximum operating temperature 60°C
Range of deck mounted, two hole, single outlet (fixed) combination tap assemblies with brass bodies (chrome plated). Incorporating quarter turn ceramic disc headworks, dome type operating members and self cancelling diverter to shower outlet. The temperature is controlled independently via a thermostatic cartridge with a dome type operating member that also incorporates a manual override button. Both inlets incorporate approved check valve cartridges, however, the complete product has not been fully tested to demonstrate it provides backflow protection. The spout outlet incorporates a plastic aerator. Models TL30024CP and TR30024CP are supplied with a shower riser rail, shower hose and shower handset. Maximum working pressure 5.0bar. Maximum operating temperature 60°C.
Range of wall mounted, two hole, single outlet (fixed) combination tap assemblies with brass bodies (chrome plated). Incorporating non-rising spindle headworks, dome type operating members and lockable, self cancelling diverter to shower outlet. The temperature is controlled independently via a thermostatic cartridge with a dome type operating member that also incorporates a manual override button. Both inlets incorporate stainless-steel strainer and approved check valve cartridges, however, the complete product has not been fully tested to demonstrate it provides backflow protection. The spout outlet incorporates a plastic aerator. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.
Wall mounted, two-hole, single outlet (swivel) combination tap assemblies (chromium plated brass), incorporating ceramic cartridge headwork with single lever operating members. The spout outlets incorporate a plastic aerator. Maximum working pressure 5.0 bar. Maximum operating temperature 65°C.
Deck mounted two hole, single outlet (fixed) combination tap assembly (chromium plated brass), incorporating quarter turn ceramic disc headworks with single lever operating members and a lockable self- cancelling diverter to the shower outlet. Temperature is controlled independently via a thermostatic cartridge with a dome type operating member that incorporates a manual override button. Both inlets incorporate stainless-steel strainers and a single check valve cartridge (however, the complete product has not been fully tested to demonstrate it provides backflow protection). The spout outlet incorporates a plastic flow straightener and a stainless steel mesh Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.
Range of wall mounted, two-hole, single outlet (fixed) combination tap assemblies (chromium plated brass) incorporating a lockable self-cancelling diverter to shower outlet. The flow is controlled by a quarter turn ceramic disc headwork with a dome operating member (model XB-SL-007 incorporates a manual override button) and the temperature is controlled independently via a thermostatic cartridge with a dome operating member and manual override button. Both inlets incorporate stainless-steel strainers and a single check valve cartridge (however, the complete product has not been fully tested to demonstrate it provides backflow protection). The spout outlet incorporates plastic aerator. Maximum working pressure 10 bar. Maximum operating temperature 60°C.
Range of wall mounted three-hole, single outlet (fixed) combination tap assemblies with brass bodies (various finishes) incorporating a quarter turn ceramic disc headwork with various operating members (see model). The spout outlets incorporate a plastic flow straightener (models GEO-109-C/P & GEO-109/220/CP) or a plastic aerator (all other models) Maximum working pressure 5.0 bar. Maximum operating temperature 65°C.
Range of three hole, single outlet (fixed) combination tap assemblies, brass bodies (various finishes) incorporating quarter turn ceramic disc headworks with various styles of operating members. The spout outlet incorporates a plastic aerator and is connected to the headworks via stainless steel braided EPDM lined hose assemblies. The product is supplied with either a lever type pop up (HIRONDELLE models) or click type waste (ICON-X & CORVAIR models). Maximum working pressure 3.5 Bar. Maximum operating temperature 60°C.
Range of wall mounted, three-hole, single outlet (fixed) combination tap assemblies (chromium plated brass). Incorporating quarter turn ceramic disc headworks and single lever operating members. The spout outlet incorporates a plastic aerator. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.
Range of wall mounted concealed, three-hole, single outlet (fixed) combination tap assemblies (brass body). Incorporating quarter turn ceramic disc headworks with dome or cube type operating members (see models). The spout outlet incorporates a plastic aerator. Maximum working pressure 10 bar. Maximum operating temperature 60°C.
Range of five-hole, single outlet (fixed) combination tap assembly (chromium plated) brass bodies incorporating a quarter turn ceramic disc headworks to control the flow with single lever operating members. The product is supplied with stainless steel braided EPDM lined flexible interconnecting hose assemblies to connect between the valves and a lockable self-cancelling diverter that controls flow between spout and shower handset. The spout outlet incorporates a plastic flow straightener. The product is supplied with a shower hose and handset. Maximum working pressure 10 bar. Maximum operating temperature 65°C.
Range of wall mounted spout outlets (brass bodies, various finishes) incorporating a plastic aerator. Maximum operating temperature 60°C.
A range of spout outlets with PVC lined stainless steel interlocked tube covered by silica gel. Model WD-PVC-09-10 is a double outlet. Maximum working temperature 65°C.
Range of dosing pumps with plastic bodies. Models PM004 & PM005 have a maximum operating pressure of 6.0 bar. All other models have a maximum operating pressure of 10.0 bar. Cold water use only.
Filling link assembly with a nylon body and EPDM ‘O’-rings. The product incorporates a screwdriver operated shut off valve and two check valve cartridges, verified by test (suitable for backflow protection against Fluid Category 3). The product is also supplied with two screwdriver operated angled spherical valves and a mounting bracket. Maximum working pressure 10.0 bar. Cold water use only.
Filling loop assemblies comprising of a stainless steel braided, EPDM lined hose, double check valve assembly with isolation valve verified by test (suitable for backflow protection against fluid category 3) and either a straight or tee isolation valve. Maximum working pressure 10.0 bar. Maximum operating temperature 85ºC.
‘Numepress’ range of stainless-steel crimp fittings incorporating EPDM and ‘O’-rings. For use with stainless steel tube. Maximum working pressure 16.0 bar. Maximum operating temperature 95°C.
Range of DZR brass couplings incorporating EPDM ‘O’-rings for use with Uponor Ecoflex Aqua and Uponor Ecoflex VIP Aqua PE-Xa pipe. For above and below ground use. Maximum working pressure 10.0 bar. Maximum operating temperature 95°C.
>B< Press range of stainless-steel SUS316L fittings for use with 316L stainless steel tube manufactured to EN10312. For above and below ground use. Maximum working pressure 16.0 bar. Maximum operating temperature 85°C.
WC dual flush drop valve comprising of a plastic body, silicone seating washer and an internal overflow. The valve is operated via a push button assembly (not included) for either full or reduced flush. Cold water use only.
Range of plate heat exchanger with stainless steel bodies. Maximum working pressure10 bar. Maximum operating temperature 100°C.
‘POD’ range of indirect and direct heat interface units providing space heating and instantaneous hot water. The heat transfer is generated via plate heat exchangers. The domestic hot water (DHW) circuit incorporates an adjustable temperature mixing valve. The indirect models incorporate an expansion vessel (on the CW inlet of the DHW circuit) and a pressure relief valve set at 3.0 bar (on the space heating circuit). The indirect models only are supplied with a temporary filling loop, which comprises of a stainless steel braided EPDM lined flexible hose assembly and a lever operated spherical valve for connection to the primary circuit. The angled cold water inlet incorporates an isolation valve and a branch to connect to the filling loop, which includes a double check valve assembly (verified by test, suitable for backflow protection against Fluid Category 3). Maximum working pressure for indirect units: Primary circuit: 16.0 bar. Space heating: 2.5 bar. Secondary circuit (DHW): 10.0 bar. Maximum working pressure for direct units: Primary circuit: 10.0 bar. Space heating: 10.0 bar. Secondary circuit (DHW): 10.0 bar. Maximum operating temperature for domestic hot water 65°C. Maximum operating temperature for central heating and primary circuit 85°C.
Range of wall mounted, gas-fired, condensing combination boilers providing domestic hot water via a plate heat exchanger. The pressurised central heating system incorporates an expansion vessel and a pressure relief valve set at 3.0 bar. The inlets to the domestic hot water and primary circuits each have a screwdriver operated angled spherical valve. Both include a ½” BSP (M) connection for a filling link. The Greenstar CDi models only are supplied with an integral charging link (CAB device) verified by test (suitable for backflow protection against Fluid Category 3). Maximum working pressure of the primary circuit is 2.5 bar. Maximum working pressure of the secondary circuit is 10.0 bar. Maximum operating temperature of primary circuit is 82°C. Maximum operating temperature of secondary circuit is 60°C.
Range of commercial ice making machines with flow controlled via solenoid valve. Maximum working pressure 8 bar. Cold water use.
‘RSM’ range of ultrasonic water meters with blue epoxy coated ductile iron bodies, stainless steel transducer and EPDM ‘O’-rings. Maximum working pressure 16.0 bar. Maximum operating temperature 50°C.
Range of water meters with blue epoxy coated iron bodies and EPDM ‘O’-rings. Maximum working pressure 16.0 bar. Maximum operating temperature 85°C.
Range of water meter manifolds with gun metal bodies and ball valve with either a quarter turn stop valve or screw down stop valve. The products incorporate an approved check valve cartridge however, the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum working pressure 16.0 bar. Cold water use only.
Range of three or four-hole single outlet (swivel) combination tap assemblies with brass bodies (various finishes). Four hole models Incorporate quarter turn ceramic disc headworks with single lever operating members and a self-cancelling diverter to a shower outlet.. Three hole models Incorporate a ceramic cartridge headwork with a single lever operating member and a self-cancelling diverter to a shower outlet. The spout outlet incorporates a plastic aerator and is connected to the headworks via stainless steel braided PEX lined hose assemblies. The product is supplied with a shower hose and shower handset. Maximum working pressure 5.0 bar. Maximum working temperature 60°C.
Range of concealed thermostatic mixing valves with DZR brass bodies incorporating a thermostatic cartridge controlling the temperature. The inlets incorporate asingle check valve cartridges, however, the complete product has not been fully tested to demonstrate it provides backflow protection Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.
Permanent filling/ pressurisation device for primary heating and chilled water closed circuits in domestic and non-domestic premises. The mains and closed circuit system pressures are continuously checked by two pressure sensors and their differential monitored by microprocessors. In the event of a fall in system pressure, and only if the mains pressure is adequate, a solenoid valve operates to allow water into the system. At all other times a second solenoid valve drains the fill chamber to waste, via tundish (meeting the requirements of an air gap to drain), and allowing air to be admitted via an automatic air vent to create an atmospheric disconnection across the transfer chamber. Maximum working pressure 6.0 Bar. Cold water use only.
Range of pressure transmitters with stainless steel bodies. Maximum working pressure 10.0 to 200.0 bar (please refer to model). Maximum operating temperature 100°C.
Range of spout outlets with brass bodies (various finishes) incorporating an aerator. Product is supplied with either a lever type pop up (HIRONDELLE models) or click type waste (ICON-X & CORVAIR models). Maximum working pressure 3.5 bar. Maximum operating temperature 60°C.
Spout end flow control device (aerator with ‘switchable’ spray formation). Maximum operating temperature 65°C.
Range of multistage pumps with brass suction and discharge bodies, stainless steel housing, shaft and impeller, and EPDM ‘O’-rings and seals. Maximum working pressure: 6.0 bar (46553 - Stuart CH 4-30 & 46554 - Stuart CH 4-40 models) or 9.0 bar (46555 - Stuart CH 4-50 &46556 - Stuart CH 4-60 models). Maximum operating temperature 65°C.
Range of booster pumps with stainless steel bodies, plastic impellers, and NBR ‘O’-rings. The products incorporate a temperature sensor, pressure sensor, pressure vessel and a non-return valve integral to the pump chamber. Maximum working pressure 6.5 bar. Maximum operating temperature 75°C.
Range of brushless DC centrifugal pumps with a plastic body. Maximum working pressure 1.0 Bar. Maximum operating temperature 70°C.
Range of single and twin shower booster pumps with brass bodies, DZR brass impellers, NBR ‘O’-ring and EPDM seals. Maximum working pressure 6.0 bar. Maximum operating temperature 60°C.
Wall mounted outlet bracket incorporating a brass body (various finishes) and EPDM ‘O’-rings. Maximum operating temperature 60°C.
Ranges of overhead shower outlets with brass bodies, chrome plated plastic shower handsets, shower sets and shower kits. The shower sets comprise of a chrome plated plastic shower handset and shower hose. The shower kits comprise of a chrome plated plastic shower handset, brass wall elbow and either stainless steel interlocked, or PVC coated, shower hoses. The inlets of the shower handsets incorporate a plastic flow regulator at the inlet. Shower kits with ½” (M) inlets are also supplied with a brass wall elbow which incorporate a plastic flow regulator and an approved single check valve cartridge (however, the complete product has not been fully tested to demonstrate it provides backflow protection). Maximum operating temperature 60°C.
Range of shower outlets (celing or wall mounted arms - see model) with chrome plated brass bodies and silicone nozzles. The products incorporate a swivel joint connection to the shower head which incorporates a combined NBR washer and stainless steel strainer. All models, except for the 15199 model, include a plastic flow regulator on the inlet to the shower head. Maximum operating temperature 60°C.
Range of overhead shower outlets with brass bodies (various finishes, see model), incorporating stainless steel strainer and flow regulator on the inlets. Maximum operating temperature 60°C.
Range of shower handsets with plastic bodies incorporating an integral filters. The inlet incorporates a combined washer and a strainer, plastic flow regulator and an approved check valve cartridge, however, the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum operating temperature 60°C
Range of shower handsets with chrome plated ABS plastic bodies. Maximum operating temperature 65°C
Wall mounted overhead shower outlets with (chrome plated) brass bodies and EPDM ‘O’-rings. Maximum operating temperature 65°C.
Range of shower arms, ceiling arms, water intakes and wall mounted outlet brackets (all models excluding INOX are chrome plated brass, INOX models are stainless steel). Maximum operating temperature 60.0°C
Range of wall mounted hose union taps (brass body or DZR brass body - see model) incorporating a non-rising spindle headwork with a ‘T’-type operating member. The 1BCB001 & 1BCB701 models incorporate two approved single check valve cartridges, however the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum working pressure 14.0 Bar. Maximum operating temperature 85°C.
Page 2 of 9
We use cookies to give you the best possible experience with WRAS. Some are essential to provide website functions and ensure the website is secure. We also use cookies to help us understand how people use the site and to make improvements. Click "Accept All" to enable recommended settings or click "Manage cookies" to adjust your settings. For more details, see our Cookie Policy.