Toolstation Ltd. Approvals


#2001107

Deck mounted, single hole, single outlet (fixed) pillar taps, incorporating a non-rising spindle headwork with dome type operating members. The spout outlet incorporates a plastic flow straightener and the product is supplied with metal back nuts. Maximum working pressure 10.0 bar. Maximum operating temperature 70°C.

Section:
1800 Taps
Section Subtitle:
Pillar.
WRAS Approval Number:
2001107
Expiry date:
31/01/2025
Size:
½” BSP male
Marking:
ebb & flo (Trademark of Toolstation) on rear of tap body.
Installation Requirements:
R001 R006
Model:
52398 CONTRACT PILLAR TAPS
Approval Holder:
Toolstation Ltd.
Company Name
Toolstation Ltd.
Address
Travis Perkins PLC Ryehill House Rye Hill Close Lodge Farm Industrial Estate Northampton
Phone
07392109053
General Email
benjamin.cockerill@travisperkins.co.uk

View All Listings by this Company

Print This Approval


#2002804

Self closing basin tap (chromium plated brass) with spring loaded headwork and dome type operating members. The spout outlets incorporate a plastic flow straightener and the products are supplied with metal backnuts. Maximum working pressure 10.0 bar, Maximum operating temperature 85°C.

Section:
1820 Taps
Section Subtitle:
Self closing.
WRAS Approval Number:
2002804
Expiry date:
28/02/2025
Size:
½” BSP (M)
Marking:
ebb & flo on tap base
Installation Requirements:
R001 R006
Model:
60081 Non Concussive Basin & 35537 Non Concussive COMBINATION TAP ASSEMBLIES
Approval Holder:
Toolstation Ltd.
Company Name
Toolstation Ltd.
Address
Travis Perkins PLC Ryehill House Rye Hill Close Lodge Farm Industrial Estate Northampton
Phone
07392109053
General Email
benjamin.cockerill@travisperkins.co.uk

View All Listings by this Company

Print This Approval


#1912069

Range of in-line servicing valves (brass or nickel-plated brass body and ball) with EPDM gaskets and a screwdriver operating member. Maximum working pressure 16.0 bar. Maximum operating temperature 85°C.

Section:
2260 Valves
Section Subtitle:
Spherical, metal.
WRAS Approval Number:
1912069
Expiry date:
31/12/2024
Size:
22mm compression inlet/outlet
Marking:
TS, SIZE, FLOW ARROW, BATCH CODE & V ON BODY EN1254-2 & SIZE ON NUT
Installation Requirements:
R001
Model:
Screwdriver operated. 42958 (Nickel plated Brass)
Approval Holder:
Toolstation Ltd.
Company Name
Toolstation Ltd.
Address
Travis Perkins PLC Ryehill House Rye Hill Close Lodge Farm Industrial Estate Northampton
Phone
07392109053
General Email
benjamin.cockerill@travisperkins.co.uk

View All Listings by this Company

Print This Approval


#1912070

Range of wall mounted hose union taps (various body materials) incorporating a non-rising spindle headwork with a butterfly handle operating member. The spout outlets incorporate a hose union connector. Maximum working pressure 16.0 Bar. Maximum operating temperature 85°C.

Section:
1780 Taps
Section Subtitle:
Hose union. a. All cold water fittings located outside the thermal envelope, or those outside the building should be protected against damage by freezing. b. A servicing valve shall be fitted to the supply pipe to this fitting and shall be located within the thermal envelope of the building. Where in existing house installations a hosepipe is to be used from an existing hose union tap located outside a house and which is not provided with backflow protection, either: a. The existing hose union tap should be provided with a double check valve (Type EC or ED) located inside the building; or b. The tap should be replaced with a hose union tap that incorporates a double check valve (type HUK1); or c. A hose union backflow prevention (Type HA) or a double check valve should be continuously fitted to the outlet of the tap; or d. Is legally installed in any premises.
WRAS Approval Number:
1912070
Expiry date:
31/12/2024
Size:
½” BSP (M)
Marking:
TS, SIZE, BATCH CODE, EN1213 7 V ON BODY
Installation Requirements:
R001 R040
Model:
60635 (natural brass).
Approval Holder:
Toolstation Ltd.
Company Name
Toolstation Ltd.
Address
Travis Perkins PLC Ryehill House Rye Hill Close Lodge Farm Industrial Estate Northampton
Phone
07392109053
General Email
benjamin.cockerill@travisperkins.co.uk

View All Listings by this Company

Print This Approval


#2005045

Range of double check valve assemblies consisting of two spring loaded in-line check valve cartridges housed in a DZR brass body with a drain port between the cartridges. Maximum working pressure 10.0 bar. Maximum operating temperature 85°C.

Section:
0034 Backflow Prevention Devices
Section Subtitle:
SCHEDULE 2 - Section 6.2 Type ED - Non-verifiable double check valve.
WRAS Approval Number:
2005045
Expiry date:
31/05/2025
Note:
Not for use with water injected with CO2 gas.
Size:
See model.
Marking:
TS, CR FLOW ARROW & SIZE ON BODY SIZE ON END NUT
Installation Requirements:
R001
Model:
86881: 15mm compression inlet/outlet, 61921: 22mm compression inlet/outlet,
Approval Holder:
Toolstation Ltd.
Company Name
Toolstation Ltd.
Address
Travis Perkins PLC Ryehill House Rye Hill Close Lodge Farm Industrial Estate Northampton
Phone
07392109053
General Email
benjamin.cockerill@travisperkins.co.uk

View All Listings by this Company

Print This Approval


#2007077

Single hole, single outlet (fixed) combination tap assembly (chromium plated brass), incorporating a ceramic cartridge headwork with a single lever operating member. The spout outlet incorporates a plastic flow straightener. The product is supplied with a click type waste. Maximum working pressure 10 bar. Maximum operating temperature 70°C.

Section:
0450 Combination Tap Assemblies
Section Subtitle:
Single hole, single outlet, fixed. Taps used in high risk installations, such as kitchen sinks, are considered to be a fluid category 5 risk. Backflow protection is usually provided in the form of an AUK3 tap gap. Where an AUK3 tap gap cannot be maintained, for example where the tap gap is compromised as a result of: • the tap being lowered in any way; • adjustment to the spout which reduces the distance between the tap outlet and spillover level of the sink; • or the operation of a pull out hose attachment; alternative fluid category 5 backflow protection is required.
WRAS Approval Number:
2007077
Expiry date:
31/07/2025
Size:
Stainless steel braided EPDM lined flexible hose assemblies with ½” captive nut end connections.
Marking:
ebb & flo (brand of Toolstation) on tap body.
Installation Requirements:
R001 R006 R010
Model:
20761
Approval Holder:
Toolstation Ltd.
Company Name
Toolstation Ltd.
Address
Travis Perkins PLC Ryehill House Rye Hill Close Lodge Farm Industrial Estate Northampton
Phone
07392109053
General Email
benjamin.cockerill@travisperkins.co.uk

View All Listings by this Company

Print This Approval


#2010403

Single hole, single outlet (swivel) comination tap assembly (chromium plated brass), incorporation a non-rising spindleheadwork with crosstop type operating members. The spout outlets incorporate a metal strainer and either a plastic aerator or alternative flow straightener. Maximum working pressure 10.0 bar. Maximum operating temperature 70°C.

Section:
0470 Combination Tap Assemblies
Section Subtitle:
Single hole, single outlet, swivel. Taps used in high risk installations, such as kitchen sinks, are considered to be a fluid category 5 risk. Backflow protection is usually provided in the form of an AUK3 tap gap. Where an AUK3 tap gap cannot be maintained, for example where the tap gap is compromised as a result of:- • the tap being lowered in any way; • adjustment to the spout which reduces the distance between the tap outlet and spillover level of the sink; • or the operation of a pull out hose attachment; alternative fluid category 5 backflow protection is required.
WRAS Approval Number:
2010403
Expiry date:
31/10/2025
Size:
Stainless steel braided EPDM lined hose assembly with ½” BSP captive nut.
Marking:
ebb & flo on tap base
Installation Requirements:
R001 R006 R010
Model:
49944
Approval Holder:
Toolstation Ltd.
Company Name
Toolstation Ltd.
Address
Travis Perkins PLC Ryehill House Rye Hill Close Lodge Farm Industrial Estate Northampton
Phone
07392109053
General Email
benjamin.cockerill@travisperkins.co.uk

View All Listings by this Company

Print This Approval


#2010404

Single hole, single outlet (swivel) comination tap assembly (chromium plated brass). Incorporation a ceramic disc headwork with dome type operating members. The spout outlets incorporate a metal strainer and either a plastic aerator or alternative flow straightener. Maximum working pressure 10.0 bar. Maximum operating temperature 70°C.

Section:
0470 Combination Tap Assemblies
Section Subtitle:
Single hole, single outlet, swivel. Taps used in high risk installations, such as kitchen sinks, are considered to be a fluid category 5 risk. Backflow protection is usually provided in the form of an AUK3 tap gap. Where an AUK3 tap gap cannot be maintained, for example where the tap gap is compromised as a result of:- • the tap being lowered in any way; • adjustment to the spout which reduces the distance between the tap outlet and spillover level of the sink; • or the operation of a pull out hose attachment; alternative fluid category 5 backflow protection is required.
WRAS Approval Number:
2010404
Expiry date:
31/10/2025
Size:
Stainless steel braided EPDM lined hose assembly with ½” BSP captive nut.
Marking:
ebb & flo on base of tap
Installation Requirements:
R001 R006 R010
Model:
88081 COLWELL MONO MIXER COMINATION TAP ASSEMBLY
Approval Holder:
Toolstation Ltd.
Company Name
Toolstation Ltd.
Address
Travis Perkins PLC Ryehill House Rye Hill Close Lodge Farm Industrial Estate Northampton
Phone
07392109053
General Email
benjamin.cockerill@travisperkins.co.uk

View All Listings by this Company

Print This Approval


#2001141

Range of deck mounted, single hole, single outlet (fixed) pillar taps, incorporating a non-rising spindle headwork with cross top operating members. The spout outlet incorporates a plastic flow straightener and the product is supplied with metal back nuts. Maximum working pressure 10.0 bar. Maximum operating temperature 70°C.

Section:
1800 Taps
Section Subtitle:
Pillar.
WRAS Approval Number:
2001141
Expiry date:
31/01/2025
Size:
½” BSP male
Marking:
ebb & flo on tap body.
Installation Requirements:
R001 R006
Model:
64284 Cross head Kitchen PILLAR TAPS
Approval Holder:
Toolstation Ltd.
Company Name
Toolstation Ltd.
Address
Travis Perkins PLC Ryehill House Rye Hill Close Lodge Farm Industrial Estate Northampton
Phone
07392109053
General Email
benjamin.cockerill@travisperkins.co.uk

View All Listings by this Company

Print This Approval


#2010405

Single hole, single outlet (swivel) comination tap assembly (chromium plated brass), incorporation a ceramic disc headwork with lever type operating members.The spout outlets incorporate a metal strainer and either a plastic aerator or alternative flow straightener. Maximum working pressure 10.0 bar. Maximum operating temperature 70°C

Section:
0470 Combination Tap Assemblies
Section Subtitle:
Single hole, single outlet, swivel. Taps used in high risk installations, such as kitchen sinks, are considered to be a fluid category 5 risk. Backflow protection is usually provided in the form of an AUK3 tap gap. Where an AUK3 tap gap cannot be maintained, for example where the tap gap is compromised as a result of:- • the tap being lowered in any way; • adjustment to the spout which reduces the distance between the tap outlet and spillover level of the sink; • or the operation of a pull out hose attachment; alternative fluid category 5 backflow protection is required.
WRAS Approval Number:
2010405
Expiry date:
31/10/2025
Size:
Stainless steel braided EPDM lined hose assembly with ½” BSP captive nut.
Marking:
ebb & flo on base of tap
Installation Requirements:
R001 R006 R010
Model:
26251 Seaton Mono Mixer Kitchen COMINATION TAP ASSEMBLY
Approval Holder:
Toolstation Ltd.
Company Name
Toolstation Ltd.
Address
Travis Perkins PLC Ryehill House Rye Hill Close Lodge Farm Industrial Estate Northampton
Phone
07392109053
General Email
benjamin.cockerill@travisperkins.co.uk

View All Listings by this Company

Print This Approval



Back To Directory Sections

Page 1 of 5

We use cookies to give you the best possible experience with WRAS. Some are essential to provide website functions and ensure the website is secure. We also use cookies to help us understand how people use the site and to make improvements. Click "Accept All" to enable recommended settings or click "Manage cookies" to adjust your settings. For more details, see our Cookie Policy.