ALFRED VICTORIA LIMITED Approvals


#2003082

Range of T-type thermostatic blending valves with chromium plated brass bodies. The inlets incorporate a stainless-steel strainer and a check valve cartridge, verified by test (suitable for backflow protection against Fluid Category 2) Maximum working pressure 10.0 bar. Maximum operating temperature 85°C

Section:
2010 Valves
Section Subtitle:
Blending, thermostatic.
WRAS Approval Number:
2003082
Expiry date:
31/03/2025
Note:
A torque value of 35Nm shall be applied to the nuts of model TMV08 when tightening. A torque value of 50Nm shall be applied to the nuts of model TMV09 when tightening.
Size:
See model.
Marking:
ALFRED VICTORIA LTD ON BODY
Installation Requirements:
R001 R010 R040 R120
Model:
TMV08 – 15MM COMPRESSION INLET/OUTLET & TMV09– 22MM COMPRESSION INLET/OUTLET THERMOSTATIC BLENDING VALVES
Factor:
ALFRED VICTORIA LIMITED
Company Name
ALFRED VICTORIA LIMITED
Postcode
B45 9AL

View All Listings by this Company

Print This Approval


#2010080

Range of wall mounted thermostatic blending valves (chromium plated brass) incorporating either a 2 way ceramic disc diverter (models T, SH103X) controlling the flow to either an overhead shower or shower handset with various operating members (See model) or a quarter turn ceramic disc headwork (models VM90, & VM93) with various operating members. The temperature is controlled independently via a thermostatic cartridge incorporating a manual override button. The inlets incorporate approved check valve cartridge(s), however, the complete product has not been fully tested to demonstrate it provides backflow protection and stainless steel strainers. Maximum working pressure 5.0 bar. Maximum operating temperature is 85°C.

Section:
2010 Valves
Section Subtitle:
Blending, thermostatic.
WRAS Approval Number:
2010080
Expiry date:
31/10/2025
Size:
¾” x ½” BSP (M) offset unions.
Marking:
Alfred Victoria logo on body.
Installation Requirements:
R001 R040
Model:
SH103X, SH104X, VM90 & VM93
Factor:
ALFRED VICTORIA LIMITED
Company Name
ALFRED VICTORIA LIMITED
Postcode
B45 9AL

View All Listings by this Company

Print This Approval


#2205030

Wall mounted, thermostatic mixing valve (chromium plated brass body), the flow is controlled by a non-rising spindle headwork with a dome operating member and the temperature is controlled independently via a thermostatic cartridge with a dome operating member and manual override button Both inlets incorporate stainless steel strainers and approved check valve cartridges, however, the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum working pressure 5.0 bar. Maximum operating temperature 55°C.

Section:
2010 Valves
Section Subtitle:
Blending, thermostatic.
WRAS Approval Number:
2205030
Expiry date:
31/05/2027
Size:
½” BSP (M)
Marking:
ALFRED VICTORIA on valve body
Installation Requirements:
R001 R010 R040
Model:
VM37
Factor:
ALFRED VICTORIA LIMITED
Company Name
ALFRED VICTORIA LIMITED
Postcode
B45 9AL

View All Listings by this Company

Print This Approval


#2206054

Range of single hole, single outlet (swivel) combination tap assemblies (chromium plated brass) incorporating ceramic disc headwork with single lever operating members. The spout outlets incorporate plastic aerator. Maximum working pressure 10.0 bar. Maximum operating temperature 65°C.

Section:
0470 Combination Tap Assemblies
Section Subtitle:
Single hole, metal, single outlet, swivel. Taps used in high risk installations, such as kitchen sinks, are considered to be a fluid category 5 risk. Backflow protection is usually provided in the form of an AUK3 tap gap. Where an AUK3 tap gap cannot be maintained, for example where the tap gap is compromised as a result of:- • the tap being lowered in any way; • adjustment to the spout which reduces the distance between the tap outlet and spillover level of the sink; • or the operation of a pull out hose attachment; alternative fluid category 5 backflow protection is required.
WRAS Approval Number:
2206054
Expiry date:
30/06/2027
Size:
Stainless steel braided hoses with a PEX inner hose with 1/2" BSP captive nut end connection
Marking:
Alfred Victoria on front of tap body
Installation Requirements:
R001 R006 R010
Model:
PI77, TS77, G77 & UL12 COMBINATION TAP ASSEMBLIES
Factor:
ALFRED VICTORIA LIMITED
Company Name
ALFRED VICTORIA LIMITED
Postcode
B45 9AL

View All Listings by this Company

Print This Approval


#2206066

Range of single hole, single outlet (swivel) combination tap assemblies (chromium plated brass) with a ceramic cartridge headwork with a single lever operating member The spout outlets incorporate plastic aerator. Maximum working pressure 10.0 bar. Maximum operating temperature 65°C.

Section:
0470 Combination Tap Assemblies
Section Subtitle:
Single hole, metal, single outlet, swivel. Taps used in high risk installations, such as kitchen sinks, are considered to be a fluid category 5 risk. Backflow protection is usually provided in the form of an AUK3 tap gap. Where an AUK3 tap gap cannot be maintained, for example where the tap gap is compromised as a result of:- • the tap being lowered in any way; • adjustment to the spout which reduces the distance between the tap outlet and spillover level of the sink; • or the operation of a pull out hose attachment; alternative fluid category 5 backflow protection is required.
WRAS Approval Number:
2206066
Expiry date:
30/06/2027
Size:
Stainless steel braided hoses with a PEX inner hose with 1/2" BSP captive nut end connection
Marking:
Alfred Victoria on operating member
Installation Requirements:
R001 R006 R010
Model:
W67 & T79
Factor:
ALFRED VICTORIA LIMITED
Company Name
ALFRED VICTORIA LIMITED
Postcode
B45 9AL

View All Listings by this Company

Print This Approval


Show Per Page
5102050Show All

Back To Directory Sections

Page of 1

We use cookies to give you the best possible experience with WRAS. Some are essential to provide website functions and ensure the website is secure. We also use cookies to help us understand how people use the site and to make improvements. Click "Accept All" to enable recommended settings or click "Manage cookies" to adjust your settings. For more details, see our Cookie Policy.