Ideal Standard (UK) Ltd Approvals


#1901006

Single hole, single outlet (swivel) combination tap assembly (chromium plated brass), incorporating a ceramic cartridge headwork and single lever operating member. The spout outlet incorporates a plastic aerator. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C

Section:
0470 Combination Tap Assemblies
Section Subtitle:
Single hole, metal, single outlet, swivel. Taps used in high risk installations, such as kitchen sinks, are considered to be a fluid category 5 risk. Backflow protection is usually provided in the form of an AUK3 tap gap. Where an AUK3 tap gap cannot be maintained, for example where the tap gap is compromised as a result of:- • the tap being lowered in any way; • adjustment to the spout which reduces the distance between the tap outlet and spillover level of the sink; • or the operation of a pull out hose attachment; alternative fluid category 5 backflow protection is required.
WRAS Approval Number:
1901006
Expiry date:
31/07/2024
Size:
Stainless steel braided EPDM lined flexible hose assemblies with 15mm compression end connections.
Marking:
Ideal Standard on operating member.
Installation Requirements:
R001 R006 R010
Model:
B2136AA Calista.
Manufacturer:
Ideal Standard (UK) Ltd
Company Name
Ideal Standard (UK) Ltd
Address
Old Road (Lodge 1) Armitage, Rugeley, Staffordshire
Postcode
WS15 4BT

View All Listings by this Company

Print This Approval


#1904036

Handheld ablution spray set comprising of a plastic (chrome plated) interlocked TPSiV lined shower hose with a NBR ‘O’-ring and a handheld spray with a trigger mechanism. The handheld spray incorporates a plastic flow restrictor on the inlet. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.

Section:
1650 Shower Outlets
WRAS Approval Number:
1904036
Expiry date:
30/04/2024
Size:
½” BSP captive nut.
Marking:
Ideal Standard on handheld spray.
Installation Requirements:
R001 R090
Model:
B0595AA IDEALSPRAY ABLUTION SET
Factor:
Ideal Standard (UK) Ltd
Company Name
Ideal Standard (UK) Ltd
Address
Old Road (Lodge 1) Armitage, Rugeley, Staffordshire
Postcode
WS15 4BT

View All Listings by this Company

Print This Approval


#1904017

Range of deck mounted, two hole, single outlet (fixed) combination tap assemblies (chromium plated brass), incorporating quarter turn ceramic disc headworks and single lever operating members. The spout outlet incorporates a plastic flow straightener and the product is supplied with metal backnuts. Maximum working pressure 10.0 bar Maximum operating temperature 60°C.

Section:
0510 Combination Tap Assemblies
Section Subtitle:
Two hole, metal, single outlet, fixed.
WRAS Approval Number:
1904017
Expiry date:
30/04/2024
Size:
¾” BSP (M)
Marking:
Ideal Standard logo on operating member
Installation Requirements:
R001 R005 R010
Model:
BC332AA – Tyria 2 Hole Dual Control Bath Filler, BC336AA – ENTELLA 2 Hole Dual Control Bath Filler & BC338AA – Sesia 2 Hole Dual Control Bath Filler.
Factor:
Ideal Standard (UK) Ltd
Company Name
Ideal Standard (UK) Ltd
Address
Old Road (Lodge 1) Armitage, Rugeley, Staffordshire
Postcode
WS15 4BT

View All Listings by this Company

Print This Approval


#1905024

Wall mounted exposed thermostatic blending valve (chromium plated brass body) incorporating a half turn ceramic disc headwork controlling the flow with a dome type operating member. The temperature is controlled via thermostatic cartridge with a manual override button and dome type operating member. The inlets incorporate an approved check valve cartridge however, the complete product has not been fully tested to demonstrate it provides backflow protection. Also incorporates stainless steel strainers on the inlets of the valve. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C

Section:
2010 Valves
Section Subtitle:
Blending, thermostatic.
WRAS Approval Number:
1905024
Expiry date:
31/05/2024
Note:
This approval does not include a shower hose and handset.
Size:
15mm Compression.
Marking:
Ideal Standard logo on operating member.
Installation Requirements:
R001 R010 R040
Model:
A4813AA Ceratherm 100 thermostatic exposed shower mixer.
Factor:
Ideal Standard (UK) Ltd
Company Name
Ideal Standard (UK) Ltd
Address
Old Road (Lodge 1) Armitage, Rugeley, Staffordshire
Postcode
WS15 4BT

View All Listings by this Company

Print This Approval


#1905046

Single hole, single outlet (fixed) combination tap assembly (chromium plated brass), incorporating a ceramic cartridge headwork with single lever operating member and a self-cancelling diverter to shower outlet. The spout outlet incorporates a plastic flow straightener and the shower outlet connection incorporates an approved check valve cartridge however, the complete product has not been fully tested to demonstrate it provides backflow protection. The product is supplied with a shower hose and handset (which also incorporates a plastic flow restrictor). Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.

Section:
0465 Combination Tap Assemblies
Section Subtitle:
Single hole, metal single outlet, fixed, self-cancelling diverter to shower outlet. Taps used in high risk installations, such as kitchen sinks, are considered to be a fluid category 5 risk. Backflow protection is usually provided in the form of an AUK3 tap gap. Where an AUK3 tap gap cannot be maintained, for example where the tap gap is compromised as a result of:- • the tap being lowered in any way; • adjustment to the spout which reduces the distance between the tap outlet and spillover level of the sink; • or the operation of a pull out hose attachment; alternative fluid category 5 backflow protection is required.
WRAS Approval Number:
1905046
Expiry date:
31/05/2024
Size:
15mm copper tails
Marking:
Ideal standard on operating member and shower handset.
Installation Requirements:
R001 R006 R009 R030
Model:
B1957AA - Tesi 1H SL
Factor:
Ideal Standard (UK) Ltd
Company Name
Ideal Standard (UK) Ltd
Address
Old Road (Lodge 1) Armitage, Rugeley, Staffordshire
Postcode
WS15 4BT

View All Listings by this Company

Print This Approval


#1905055

Range of single hole, single outlet (fixed) combination tap assemblies (chromium plated brass) incorporating a ceramic cartridge headworks with single lever operating member. The spout outlets incorporate a plastic flow straightener. Model B1811AA is supplied with a lever type pop up waste. Maximum working pressure 10.0 bar. Maximum operating temperature 60 °C

Section:
0450 Combination Tap Assemblies
Section Subtitle:
Single hole, metal single outlet, fixed. Taps used in high risk installations, such as kitchen sinks, are considered to be a fluid category 5 risk. Backflow protection is usually provided in the form of an AUK3 tap gap. Where an AUK3 tap gap cannot be maintained, for example where the tap gap is compromised as a result of: • the tap being lowered in any way; • adjustment to the spout which reduces the distance between the tap outlet and spillover level of the sink; • or the operation of a pull out hose attachment; alternative fluid category 5 backflow protection is required.
WRAS Approval Number:
1905055
Expiry date:
31/05/2024
Note:
No testing performed on pop up waste.
Size:
Stainless steel braided polyethylene lined flexible hose assemblies incorporating ⅜” captive nut end connections.
Marking:
Ideal Standard on operating member.
Installation Requirements:
R001 R006 R009 R010
Model:
B1811AA Ceraflex SL 1 hole basin mixer PUW, B1812AA Ceraflex SL 1 hole basin mixer no waste & B1959AA Ceraflex SL 1 hole bath filler
Factor:
Ideal Standard (UK) Ltd
Company Name
Ideal Standard (UK) Ltd
Address
Old Road (Lodge 1) Armitage, Rugeley, Staffordshire
Postcode
WS15 4BT

View All Listings by this Company

Print This Approval


#1905056

Single hole, single outlet (fixed) combination tap assembly (chromium plated brass), incorporating a ceramic cartridge headwork with a single lever operating member. The spout outlet incorporates a plastic aerator. The product is supplied with a lever type pop-up waste. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.

Section:
0450 Combination Tap Assemblies
Section Subtitle:
Single hole, metal single outlet, fixed. Taps used in high risk installations, such as kitchen sinks, are considered to be a fluid category 5 risk. Backflow protection is usually provided in the form of an AUK3 tap gap. Where an AUK3 tap gap cannot be maintained, for example where the tap gap is compromised as a result of: • the tap being lowered in any way; • adjustment to the spout which reduces the distance between the tap outlet and spillover level of the sink; • or the operation of a pull out hose attachment; alternative fluid category 5 backflow protection is required.
WRAS Approval Number:
1905056
Expiry date:
31/05/2024
Note:
No testing performed on pop-up waste
Size:
Stainless steel braided polyethylene lined hose assemblies incorporating ⅜” captive nut end connections.
Marking:
Ideal Standard logo on top of operating member
Installation Requirements:
R001 R006 R009 R010
Model:
B1708AA Ceraflex Basin Mixer
Factor:
Ideal Standard (UK) Ltd
Company Name
Ideal Standard (UK) Ltd
Address
Old Road (Lodge 1) Armitage, Rugeley, Staffordshire
Postcode
WS15 4BT

View All Listings by this Company

Print This Approval


#1906015

Range of wall mounted bib taps and accessories (chromium plated brass bodies) incorporating a half turn ceramic disc headwork with cross-top operating member. The spout outlets incorporate a flow straightener or a plastic aerator. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C

Section:
1750 Taps
Section Subtitle:
Draw off, metal, bib. a. All cold water fittings located outside the thermal envelope, or those outside the building should be protected against damage by freezing. b. A servicing valve shall be fitted to the supply pipe to this fitting and shall be located within the thermal envelope of the building.
WRAS Approval Number:
1906015
Expiry date:
30/06/2024
Size:
½” BSP (M)
Marking:
ISI on underside of body.
Installation Requirements:
R001 R040
Model:
B1675AA - Nimbus & B1673AA - Nimbus 21 BIB TAPS Accessories (extensions tubes and wall mounts): B1682AA, B1681AA, B1683AA, B1684AA, B1685AA, B1686AA, B1687AA & B1688AA.
Factor:
Ideal Standard (UK) Ltd
Company Name
Ideal Standard (UK) Ltd
Address
Old Road (Lodge 1) Armitage, Rugeley, Staffordshire
Postcode
WS15 4BT

View All Listings by this Company

Print This Approval


#1906020

Wall mounted bib tap (chromium plated brass) incorporating a half turn ceramic disc headwork with cross top operating members. The spout outlet incorporates a hose union spigot connection. Maximum working pressure: 10.0 bar. Maximum operating temperature: 60°C.

Section:
1750 Taps
Section Subtitle:
Draw off, metal, bib. a. All cold water fittings located outside the thermal envelope, or those outside the building should be protected against damage by freezing. b. A servicing valve shall be fitted to the supply pipe to this fitting and shall be located within the thermal envelope of the building.
WRAS Approval Number:
1906020
Expiry date:
30/06/2024
Size:
½” BSP (M)
Marking:
ISI on body
Installation Requirements:
R001 R040
Model:
B1674AA - Nimbus 21 BIB Taps (Pair) with Hose Union
Factor:
Ideal Standard (UK) Ltd
Company Name
Ideal Standard (UK) Ltd
Address
Old Road (Lodge 1) Armitage, Rugeley, Staffordshire
Postcode
WS15 4BT

View All Listings by this Company

Print This Approval


#1907004

Single hole, single outlet (swivel) combination tap assembly (chromium plated brass) incorporating ceramic cartridge headwork with single lever operating member. The spout outlet incorporates a plastic aerator. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C

Section:
0470 Combination Tap Assemblies
Section Subtitle:
Single hole, metal, single outlet, swivel. Taps used in high risk installations, such as kitchen sinks, are considered to be a fluid category 5 risk. Backflow protection is usually provided in the form of an AUK3 tap gap. Where an AUK3 tap gap cannot be maintained, for example where the tap gap is compromised as a result of:- • the tap being lowered in any way; • adjustment to the spout which reduces the distance between the tap outlet and spillover level of the sink; • or the operation of a pull out hose attachment; alternative fluid category 5 backflow protection is required.
WRAS Approval Number:
1907004
Expiry date:
31/07/2024
Size:
Stainless steel braided polyethylene lined flexible hoses incorporating 3/8” BSP captive nut end connections, with optional 15mm compression fittings
Marking:
Ideal Standard on operating member
Installation Requirements:
R001 R006 R009 R010
Model:
B0744AA Tempo
Factor:
Ideal Standard (UK) Ltd
Company Name
Ideal Standard (UK) Ltd
Address
Old Road (Lodge 1) Armitage, Rugeley, Staffordshire
Postcode
WS15 4BT

View All Listings by this Company

Print This Approval



Back To Directory Sections

Page 1 of 5

We use cookies to give you the best possible experience with WRAS. Some are essential to provide website functions and ensure the website is secure. We also use cookies to help us understand how people use the site and to make improvements. Click "Accept All" to enable recommended settings or click "Manage cookies" to adjust your settings. For more details, see our Cookie Policy.