Heaters

Section Code 1380 : Electric, thermal storage, mains fed, closed outlet. Heat retained in water heaters will cause expansion of water after closure of draw-off taps and valves. Provision for expansion of water must be made to accommodate excess pressure within with system. Particular care is required where check valves are positioned, or loose jumper valves are thought to be upstream of the heater.

Back To Directory Sections

WRAS Approval Number: 1806315

‘Extra Life Series’ above and under sink range of electrically heated unvented water heaters (cased and insulated) incorporating a blue enamel lined steel tank. Maximum working pressure 8.0 bar. Maximum operating temperature 75°C.

  • Section: 1380 Heaters
  • Section Subtitle: Electric, thermal storage, mains fed, closed outlet. Heat retained in water heaters will cause expansion of water after closure of draw-off taps and valves. Provision for expansion of water must be made to accommodate excess pressure within with system. Particular care is required where check valves are positioned, or loose jumper valves are thought to be upstream of the heater.
  • WRAS Approval Number: 1806315
  • Expiry date: 30/06/2023
  • Size: ½” BSP (M) inlet and outlet
  • Marking: Eldom on front case. Eldom Invest Ltd, address, model number and other technical information on adhesive label on front case.
  • Installation Requirements R001 R040
  • Model
    Extra Life Series: Above sink under pressure (NMP) 72324NMP - 7 litres. 72325NMP - 10 litres. 72326NMP - 15 litres. Under sink under pressure (PMP) 72324PMP - 7 litres. 72325PMP - 10 litres. 72326PMP - 15 litres.
  • Manufacturer: ELDOMINVEST LTD.
    Company Name
    ELDOMINVEST LTD.
    View All Listings by this Company

Print This Approval


WRAS Approval Number: 1905042

‘Zip Aquapoint IV’ range of wall mounted directly heated unvented storage vessels (cased and insulated) incorporating an enamel lined cylinder and safety kit. The cylinder is factory fitted with a temperature and pressure relief valve. An inlet manifold is supplied incorporating a 6.0 bar expansion relief valve, a pressure reducing valve pre-set at 3.0 bar, a check valve cartridge, verified by test (suitable for backflow protection against Fluid Category 2) and a stainless-steel strainer. An expansion vessel is also supplied. Maximum working pressure 5.5 bar. Maximum operating temperature 70°C.

  • Section: 1380 Heaters
  • Section Subtitle: Electric, thermal storage, mains fed, closed outlet. Heat retained in water heaters will cause expansion of water after closure of draw-off taps and valves. Provision for expansion of water must be made to accommodate excess pressure within with system. Particular care is required where check valves are positioned, or loose jumper valves are thought to be upstream of the heater.
  • WRAS Approval Number: 1905042
  • Expiry date: 31/05/2024
  • Size: ½” BSP (M) inlet and outlets.
  • Marking: Zip and technical information (including maximum working pressure and capacity) on adhesive label on body.
  • Installation Requirements R001
  • Model
    Zip Aquapoint IV range consisting of models: AP430S - 30L Direct, AP450S - 50L Direct, AP480S - 80L Direct & AP4100S - 100L Direct.
  • Factor: Zip Heaters UK Ltd T/A Zip Water UK
    Company Name
    Zip Heaters UK Ltd T/A Zip Water UK
    View All Listings by this Company

Print This Approval


WRAS Approval Number: 2003062

Gledhill ATLANTIC Ondeo range of under and over sink, closed outlet electric water heaters. Incorporating an enamel lined cylinder and pressure relief valve (set at 6.0 bar). Maximum operating pressure 5.5 bar. Maximum operating temperature 85˚C

  • Section: 1380 Heaters
  • Section Subtitle: Electric, thermal storage, mains fed, closed outlet. Heat retained in water heaters will cause expansion of water after closure of draw-off taps and valves. Provision for expansion of water must be made to accommodate excess pressure within with system. Particular care is required where check valves are positioned, or loose jumper valves are thought to be upstream of the heater.
  • WRAS Approval Number: 2003062
  • Expiry date: 31/03/2025
  • Size: ½” BSP (M) inlet and Outlet.
  • Marking: ATLANTIC, model number and technical information including capacity on adhesive label on unit.
  • Installation Requirements R001
  • Model
    821451-Below Sink 10Ltr water heater, 821452-Below Sink 15lLtr water heater, 821449-Above Sink 10Ltr water Heater, 821450-Above Sink 15Ltr water Heater.
  • Manufacturer: ATLANTIC INTERNATIONAL
    Company Name
    ATLANTIC INTERNATIONAL
    View All Listings by this Company

Print This Approval


WRAS Approval Number: 2004049

Range of water heaters incorporating a pressure relief valve pre-set at 6.0 bar. Maximum working pressure 5.5 bar. Maximum operating temperature 75ºC.

  • Section: 1380 Heaters
  • Section Subtitle: Electric, thermal storage, mains fed, closed outlet. Heat retained in water heaters will cause expansion of water after closure of draw-off taps and valves. Provision for expansion of water must be made to accommodate excess pressure within with system. Particular care is required where check valves are positioned, or loose jumper valves are thought to be upstream of the heater.
  • WRAS Approval Number: 2004049
  • Expiry date: 30/04/2025
  • Size: ½” BSP (M) X ½” BSP (M).
  • Marking: Hyco on body. Product code and technical information on adhesive label on body.
  • Installation Requirements R001
  • Model
    SF10SS SF15SS SF1012SS SF1512SS
  • Factor: Hyco Manufacturing Ltd.
    Company Name
    Hyco Manufacturing Ltd.
    View All Listings by this Company

Print This Approval