Emas Makina Sanayi A.S. Approvals


#1905007

EMAS range of combination boilers with instant hot water and central heating system with a stainless-steel plate heat exchanger. Hot water is produced via heat from a centralised heating system (not supplied). The unit incorporates a pressure relief valve set at 3.0 bar and an expansion vessel on the central heating circuit. The inlet and outlet of the primary and secondary circuits fitted with isolation valves. Maximum working pressure: primary circuit 2.5 bar & secondary circuit 10.0 bar. Maximum operating temperature: primary circuit 70˚C & secondary circuit 50˚C.

Section:
1465 Heaters
Section Subtitle:
Combination boilers and Water Jacketed Tube heaters. Low volume water content. Heat retained in water heaters will cause expansion of water after closure of draw-off taps and valves. Provision for expansion of water must be made to accommodate excess pressure within the system. Particular care is required where check valves are positioned, or loose jumper valves are thought to be upstream of the heater.
WRAS Approval Number:
1905007
Expiry date:
31/05/2024
Size:
Primary: ¾” BSP (M) inlet and outlet. Secondary: ½” BSP (M) inlet and outlet.
Marking:
E.C.A (manufacturer’s brand), model and technical information on adhesive label on side of boiler. E.C.A logo on front of boiler.
Installation Requirements:
R001 R360
Model:
Proteus Premix 24 HM Proteus Premix 28 HM Proteus Premix 30 HM Proteus Premix 35 HM
Manufacturer:
Emas Makina Sanayi A.S.
Company Name
Emas Makina Sanayi A.S.
Address
Organize Sanayi Bolgasi 3 Kisim Mustafa Kemal Bulvari N013 Turkey

View All Listings by this Company

Print This Approval


#1905089

PREMIX range of combination boilers with instant hot water and central heating system with a stainless-steel plate heat exchanger. Hot water is produced via heat from a centralised heating system (not supplied). The unit incorporates a pressure relief valve set at 3.0 bar and an expansion vessel on the central heating circuit. The inlet and outlet of the primary and secondary circuits fitted with isolation valves. Maximum working pressure: primary circuit 2.5 bar & secondary circuit 10.0 bar. Maximum operating temperature: primary circuit 70˚C & secondary circuit 50˚C.

Section:
1465 Heaters
Section Subtitle:
Combination boilers and Water Jacketed Tube heaters. Low volume water content. Heat retained in water heaters will cause expansion of water after closure of draw-off taps and valves. Provision for expansion of water must be made to accommodate excess pressure within the system. Particular care is required where check valves are positioned, or loose jumper valves are thought to be upstream of the heater.
WRAS Approval Number:
1905089
Expiry date:
31/05/2024
Size:
Primary: ¾” BSP (M) inlet and outlet. Secondary: ½” BSP (M) inlet and outlet.
Marking:
E.C.A (manufacturer’s brand), model and technical information on adhesive label on side of boiler. E.C.A logo on front of boiler.
Installation Requirements:
R001 R360
Model:
PROTEUS PREMIX 14 HM, PROTEUS PREMIX 20 HM, CONFEO PREMIX 14 HM, CONFEO PREMIX 20 HM, CONFEO PREMIX 24 HM, CONFEO PREMIX 28 HM, CONFEO PREMIX 30 HM & CONFEO PREMIX 35 HM
Factor:
Emas Makina Sanayi A.S.
Company Name
Emas Makina Sanayi A.S.
Address
Organize Sanayi Bolgasi 3 Kisim Mustafa Kemal Bulvari N013 Turkey

View All Listings by this Company

Print This Approval


#2101041

Gas fired water heaters incorporating a heat exchanger and flow sensor. The inlet incorporates a plastic strainer. The products are supplied with isolation valves for installation on the cold inlet and hot outlet. Maximum working pressure 10.0 bar. Maximum operating temperature 60˚C

Section:
1400 Heaters
Section Subtitle:
Gas fired, closed outlet. Heat retained in water heaters may cause expansion of water after closure of draw-off taps and valves. Provision for expansion of water must be made to prevent excess pressure within the system.
WRAS Approval Number:
2101041
Expiry date:
31/01/2026
Size:
15mm Compression
Marking:
ECA on front of body. ECA. Model & technical information on adhesive label on side of body.
Installation Requirements:
R001 R140
Model:
8116180100 – Phoenix PH 11LT Water Heater.
Manufacturer:
Emas Makina Sanayi A.S.
Company Name
Emas Makina Sanayi A.S.
Address
Organize Sanayi Bolgasi 3 Kisim Mustafa Kemal Bulvari N013 Turkey

View All Listings by this Company

Print This Approval


#2205321

Range of electric combination boilers providing heating and instantaneous hot water. The heating system incorporates an expansion vessel and pressure relief valve (set at 3.0 bar). The DHW inlet and outlet incorporate spherical servicing valves. Fittited with a CAB device keyless filling link, verifired by test, suitable for category 3 backlfow protection. Maximum working pressure on central heating circuit 2.5 bar & Domestic Hot Water 10bar. Maximum operating temperature 80°C

Section:
1465 Heaters
Section Subtitle:
Combination boilers and Water Jacketed Tube heaters. Low volume water content. Heat retained in water heaters will cause expansion of water after closure of draw-off taps and valves. Provision for expansion of water must be made to accommodate excess pressure within the system. Particular care is required where check valves are positioned, or loose jumper valves are thought to be upstream of the heater.
WRAS Approval Number:
2205321
Expiry date:
31/05/2027
Size:
15mm compression x 22mm compression.
Marking:
E.C.A on front casing. Manufacturer, address, model no, QR code and other technical information on side panel.
Installation Requirements:
R001 R140
Model:
8116270010 - Arceus/Cure plus/Electus EK 12 MT UK, 8116271010 - Arceus/Cure plus/Electus EK 15 MT UK, 8116272010 - Arceus/Cure plus/Electus EK 18 MT UK 8116273010 - Arceus/Cure plus/Electus EK 24 MT UK & 8116274010 - Arceus/Cure plus/Electus EK 27 MT UK
Manufacturer:
Emas Makina Sanayi A.S.
Company Name
Emas Makina Sanayi A.S.
Address
Organize Sanayi Bolgasi 3 Kisim Mustafa Kemal Bulvari N013 Turkey

View All Listings by this Company

Print This Approval


Show Per Page
5102050Show All

Back To Directory Sections

Page of 1

We use cookies to give you the best possible experience with WRAS. Some are essential to provide website functions and ensure the website is secure. We also use cookies to help us understand how people use the site and to make improvements. Click "Accept All" to enable recommended settings or click "Manage cookies" to adjust your settings. For more details, see our Cookie Policy.