Vital Energi Utilities Limited Approvals


#1910338

Electronically controlled Heat interface units (HIU) with twin stainless-steel plate heat exchangers providing space heating and instantaneous hot water. The cold inlet supply to the plate heat exchanger incorporates an isolation valve, in line single check valve assembly, (suitable for backflow protection against Fluid Category 2) and and water hammer arrestor. The space heating circuit incorporates an expansion vessel and a pressure relief valve (set at 3.0 bar). The product is supplied with a filling loop comprising of an in-line double check valve assembly (suitable for backflow protection against Fluid Category 3), which incorporates an isolation valve, a stainless-steel braided EPDM lined flexible hose assembly. The inlet and outlet of all circuits incorporates a lever operated spherical valves with brass bodies. Maximum working pressures and operating temperatures: Primary: 16.0 bar and 90˚C. Domestic hot water (DHW): 10.0 bar and 60˚C. Secondary (space heating): 2.5 bar and 90˚C.

Section:
1465 Heaters
Section Subtitle:
Combination boilers and Water Jacketed Tube heaters. Low volume water content. Heat retained in water heaters will cause expansion of water after closure of draw-off taps and valves. Provision for expansion of water must be made to accommodate excess pressure within the system. Particular care is required where check valves are positioned, or loose jumper valves are thought to be upstream of the heater.
WRAS Approval Number:
1910338
Expiry date:
31/10/2024
Note:
Supplied with a temporary filling loop. The filling loop must be installed with the appropriate backflow prevention device in accordance with clause G24.2, Guidance to the Water Supply (Water Fittings) Regulations 1999.
Size:
¾” BSP (F) inlet/outlet on all circuits.
Marking:
Vtherm on front.
Installation Requirements:
R001
Model:
Vital Energi vTherm
Factor:
Vital Energi Utilities Limited
Company Name
Vital Energi Utilities Limited
Address
Century House Roman Road Blackburn
Postcode
BB1 2LD
Phone
01254 296000
General Email
sales@vitalenergi.co.uk

View All Listings by this Company

Print This Approval


#2001363

Electronically controlled heat interface units (HIU) with twin stainless-steel plate heat exchangers providing space heating and instantaneous hot water. The cold inlet supply to the plate heat exchanger incorporates an isolation valve, in line single check valve assembly, (suitable for backflow protection against Fluid Category 2) and a water hammer arrestor. The space heating circuit incorporates an expansion vessel and a pressure relief valve (set at 3.0 bar). The product is supplied with a filling loop comprising of an in-line double check valve assembly (suitable for backflow protection against Fluid Category 3), which incorporates an isolation valve, a stainless-steel braided EPDM lined flexible hose assembly and an isolation valve. The inlet and outlet of all circuits incorporates lever operated spherical valves with brass bodies. Maximum working pressures and operating temperatures: Primary: 16.0 bar and 90˚C. Domestic hot water (DHW): 10.0 bar and 60˚C. Secondary (space heating): 2.5 bar and 90˚C.

Section:
1465 Heaters
Section Subtitle:
Combination boilers and Water Jacketed Tube heaters. Low volume water content. Heat retained in water heaters will cause expansion of water after closure of draw-off taps and valves. Provision for expansion of water must be made to accommodate excess pressure within the system. Particular care is required where check valves are positioned, or loose jumper valves are thought to be upstream of the heater.
WRAS Approval Number:
2001363
Expiry date:
31/01/2025
Note:
Supplied with a temporary filling loop. The filling loop must be installed with the appropriate backflow prevention device in accordance with clause G24.2, Guidance to the Water Supply (Water Fittings) Regulations 1999.
Size:
¾” BSP (F) inlet/outlet on all circuits.
Marking:
V Therm on face of unit. Data label, Model, Vital Energi, pressure, date of manufacture (YYYY-MM) and other technical information on adhesive label on rear panel inside the appliance.
Installation Requirements:
R001
Model:
Vital Energi vTherm°h Hybrid Indirect Hydraulic Interface Unit with Insulated Casing.
Factor:
Vital Energi Utilities Limited
Company Name
Vital Energi Utilities Limited
Address
Century House Roman Road Blackburn
Postcode
BB1 2LD
Phone
01254 296000
General Email
sales@vitalenergi.co.uk

View All Listings by this Company

Print This Approval


#2206320

Range of in-line non-verifiable single check valve assemblies consisting of a spring loaded resilient trim single check valve cartridge housed within a DZR brass brass body. Maximum working pressure 10.0 bar. Maximum operating temperature 85°C.

Section:
0030 Backflow Prevention Devices
Section Subtitle:
SCHEDULE 2 - Section 6.2 Type EB - Non verifiable single check valve.
WRAS Approval Number:
2206320
Expiry date:
30/06/2027
Size:
see model
Marking:
V Therm, flow arrow, size, PN16 and CR etched on body
Installation Requirements:
R001
Model:
vTherm STVSN0454 – ¾” BSP (M) vTherm STVSN0455 – 1” BSP (M)
Factor:
Vital Energi Utilities Limited
Company Name
Vital Energi Utilities Limited
Address
Century House Roman Road Blackburn
Postcode
BB1 2LD
Phone
01254 296000
General Email
sales@vitalenergi.co.uk

View All Listings by this Company

Print This Approval


Show Per Page
5102050Show All

Back To Directory Sections

Page of 1

We use cookies to give you the best possible experience with WRAS. Some are essential to provide website functions and ensure the website is secure. We also use cookies to help us understand how people use the site and to make improvements. Click "Accept All" to enable recommended settings or click "Manage cookies" to adjust your settings. For more details, see our Cookie Policy.