Section Code 2390 : Dish. Washing machines in this section will indicate the category of backflow prevention built into each appliance. The location and the use of the washing machine will determine any additional backflow protection that may be required.
Back To Directory SectionsRange of undercounter commercial dishwashing machines, flow is controlled via solenoid valve that discharges via a Type ‘AA’ air gap. The machine incorporates a salt regenerated water softener. Maximum working pressure 4.0 Bar. Cold water only
Range of hood type commercial dishwashing machines. Flow is controlled via solenoid valve and discharges via a Type ‘AA’ air gap. The machines with ‘SOFT’ in the model incorporate a salt regenerated water softener. Maximum working pressure 4.0 bar. Maximum operating temperature 60°C
Range of front loading commercial dishwashers with flow controlled by solenoid valve and discharged via a type `AB` airgap (verified by test - suitable for backflow protection against fluid category 5). Maximum working pressure 4.0 Bar. Maximum operating temperature 60°C.
Range of commercial dishwashers. Flow is controlled by a solenoid valve and discharges via a type `AB` airgap (verified by test - suitable for backflow protection against fluid category 5). E ES models incorporate a heat recovery system and a double check valve assembly. Maximum working pressure 5.0 bar. Maximum operating temperature 50°C
Range of commercial dish washing machines with flow controlled by solenoid valve and discharged via a type `AB` airgap (verified by test - suitable for backflow protection against fluid category 5). Maximum working pressure 4.0 bar. Cold water use only
Range of under counter and hood type dishwashing machines with flow controlled by solenoid valve and discharged via a type `AB` airgap (verified by test - suitable for backflow protection against fluid category 5). There is a double check valve supplied with every machine. Some models are available with AirConcept and GiO-Module options. Maximum working pressure 5.0 Bar. Models incorporating AirConcept & GiO-Module are cold water use only. All other models have a maximum operating temperature 60°C. Modification November 2019 Supplied with Airbreak to drain.
Range of conveyor type commercial dishwashing machines. Flow is controlled via solenoid valve and discharges via a type `AB` airgap (verified by test - suitable for backflow protection against fluid category 5). The product incorporates a nylon bodied inline strainer with a stainless steel screen as the inlet to the machine. Maximum working pressure 4.0 bar. Maximum operating temperature 60°C
Range of commercial dishwashers, glass washers and washer disinfectors, with solenoid valves incorporating a plastic strainer and plastic flow regulator controlling the flow and discharging via a type `AB` airgap (verified by test - suitable for backflow protection against fluid category 5), one on the cold water supply and hot water supply lines to the washing system and another as part of the steam condenser circuit (applicable models). The appliances are available with or without a water softener (ion exchange), steam condenser and additional water supply. The products are supplied with ¾” BSP (F) x ¾” BSP (M) double check valve assemblies (suitable for backflow protection against Fluid Category 3) for installation on each inlet and optional ¾” BSP (M) x ¾” BSP (F) in-line strainers (incorporating a stainless steel mesh) to be installed after the double check valve assembly. Models with a steam condenser circuit include a ‘Y’-piece connector ¾” BSP (F) inlet x ¾” BSP (M) outlets to install after the double check valve or filter (if fitted) prior to the inlet hoses. Maximum working pressure 10.0 Bar. Maximum operating temperature of product and hot supply 60°C. All other inlets are cold supply only.
Range of pass through commercial dishwashing machines (with a water softener - RA models, or without - R models). Flow is controlled by a solenoid valve, which incorporates a flow restrictor and a strainer, and discharges via a type `AB` airgap (verified by test - suitable for backflow protection against fluid category 5). . The water softener (where fitted) is located downstream of the ‘AB’ air gap. The product is supplied with a grey nylon braided EPDM lined flexible hose assembly with ¾” captive nut end connections incorporating EPDM washers. Maximum working pressure 4.0 bar. Maximum operating temperature 60°C.
Range of commercial dishwashers, glass washers and washer disinfectors, with solenoid valves incorporating a plastic strainer and plastic flow regulator controlling the flow and discharging via a type `AB` airgap (verified by test - suitable for backflow protection against fluid category 5), one on the cold water supply and hot water supply lines to the washing system and another as part of the steam condenser circuit (applicable models). The appliances are available with or without a water softener (ion exchange), steam condenser and additional water supply. The products are supplied with ¾” BSP (F) x ¾” BSP (M) double check valve assemblies (suitable for backflow protection against Fluid Category 3) for installation on each inlet and optional ¾” BSP (M) x ¾” BSP (F) in-line strainers (incorporating a stainless steel mesh) to be installed after the double check valve assembly. Models with a steam condenser circuit include a ‘Y’-piece connector ¾” BSP (F) inlet x ¾” BSP (M) outlets to install after the double check valve or filter (if fitted) prior to the inlet hoses. Maximum working pressure 10.0 Bar. Maximum operating temperature of product and hot supply 60°C. All other inlets are cold supply only.
Range of hood type and undercounter commercial dishwashing machines, flow is controlled by a solenoid valve which incorporates plastic flow regulator and discharges via a Type ‘AB’ air gap (suitable for backflow protection against fluid category 5). The products are supplied with a dual layer PVC supply hose (grey outer/black inner). Maximum working pressure 3.0 Bar. Cold supply only.
Range of front loading dishwashing machines (with a water softener - RA models, or without - R models). Flow is controlled by a solenoid valve, which incorporates a flow restrictor (5.5 lpm) and a strainer, and discharges via a type `AB` airgap (verified by test - suitable for backflow protection against fluid category 5). The water softener (where supplied) is located after the ‘AB’ air gap. The product is supplied with a grey nylon braided EPDM lined flexible hose assembly with ¾” captive nut end connections incorporating EPDM washers. Maximum working pressure 4.0 bar. Maximum operating temperature 60°C.
Range of hood type or undercounter commercial dishwashers. Flow is controlled by a solenoid valve which discharges via a type ‘AA’ air gap. Maximum working pressure 10.0 Bar. Cold water supply only.
Range of commercial dish washing machines. Flow is controlled by a solenoid valve and discharged via a type `AB` airgap (verified by test - suitable for backflow protection against fluid category 5). The product is supplied with stainless steel or nylon braided EPDM inlet hose. Maximum working pressure 4.0 bar. Cold water use only.
Frront loading dishwashing machines without water softener. Flow is controlled by a solenoid valve, which incorporates a flow restrictor (5.5 lpm) and a strainer, and discharges via a type `AB` airgap (verified by test - suitable for backflow protection against fluid category 5). The product is supplied with a grey nylon braided EPDM lined flexible hose assembly with ¾” captive nut end connections incorporating EPDM washers. Maximum working pressure 4.0 bar. Maximum operating temperature 60°C.
Range of pass through commercial dishwashing machines without water softener Flow is controlled by a solenoid valve, which incorporates a flow restrictor and a strainer, and discharges via a type `AB` airgap (verified by test - suitable for backflow protection against fluid category 5). The water softener (where fitted) is located downstream of the ‘AB’ air gap. The product is supplied with a grey nylon braided EPDM lined flexible hose assembly with ¾” captive nut end connections incorporating EPDM washers. Maximum working pressure 4.0 bar. Maximum operating temperature 60°C.
Range of commercial front loading dishwashing machines with flow controlled by solenoid and discharged via type AA air gap arrangement. The products are supplied with a grey coloured PVC supply hose. Maximum working pressure 4.0 bar. Cold water supply only.
Range of commercial conveyor type dishwashers with the flow controlled by a solenoid valve and discharged via three type AB air gaps (pre-wash, rinse and wash) (verified by test - suitable for backflow protection against fluid category 5). The products are supplied with a brass bodied ‘Y’-pattern strainer, brass adaptors ¾”x¾” (M)x(M) and (F)x(F) and dual layer PVC inlet hoes(s) (grey outer/black inner) and EPDM washers. The DR*11**** model has two solenoids and requires three inlet hoses and also includes a brass tee-piece to connect them ¾”x¾”x¾” (M). Maximum working pressure 6.0 bar. Maximum operating temperature 60ºC.
Range of commercial dish washing machines with flow controlled by solenoid valve and discharged via a type `AB` airgap (verified by test - suitable for backflow protection against fluid category 5). Maximum working pressure 4.0 bar. Cold water use only
Range of commercial dish washing machines. Flow is controlled by a solenoid valve and discharged via a type `AB` airgap (verified by test - suitable for backflow protection against fluid category 5). The product is supplied with stainless steel or nylon braided EPDM inlet hose. Maximum working pressure 4.0 bar. Cold water use only.
Range of commercial front loading dishwashing machines with flow controlled by solenoid and discharged via type AA air gap arrangement. The products are supplied with a grey coloured PVC supply hose. Maximum working pressure 4.0 bar. Cold water supply only.
Range of commercial dishwashers with flow controlled by a solenoid valve and discharged via a type AB air gap (verified by test - suitable for backflow protection against fluid category 5). Maximum working pressure 4.0 bar. Cold water use only.
Range of commercial dishwashers with flow controlled by a solenoid valve and discharged via a type AB air gap (verified by test - suitable for backflow protection against fluid category 5). Maximum working pressure 4.0 bar. Cold water use only.
Range of commercial front loading, hood type & utensil washer type dishwashing machines with flow controlled by solenoid and discharged via type AB air gap (verified by test - suitable for backflow protection against fluid category 5) . The products are supplied with a grey coloured PVC supply hose. Maximum working pressure 6.0 bar. Maximum operating temperature 90°C.
Range of undercounter and passthrough commerical dishwashers with flow controlled by a solenoid valve and discharged via a type AB air gap (verified by test - suitable for backflow protection against fluid category 5). The inlet hose incorporates a stainless steel strainer. Maximum working pressure 4.0 bar. Maximum operating temperature 55°C.
Range of commercial dish washing machines with flow controlled by a solenoid valve and discharged via a type `AB` airgap (verified by test - suitable for backflow protection against fluid category 5). Maximum working pressure 4.0 bar. Cold water use only.