SIKA Systemtechnik GmbH Approvals


#2007318

Range of flow sensors incorporating either brass, plastic or stainless steel bodies & EPDM ‘O’-rings. Maximum working pressure 10.0 bar for models VVXA, VVXC, VVXB. Maximum working pressure 16.0 bar for models VVXD & VVXE. Maximum operating temperature 90°C.

Section:
1530 Miscellaneous Fittings
WRAS Approval Number:
2007318
Expiry date:
31/07/2025
Size:
See model
Marking:
SIKA, technical information & date of manufacture (WWYY) on body.
Installation Requirements:
R001
Model:
VVX Series: VVXA - plastic (¾” BSP (M) & ½” NPT (M)) VVXC - plastic (Quick-Fasten, 1” BSP (M) & ¾"NPT (M)) VVXB - plastic (1 ¼” BSP (M) & 1” NPT (M)) VVXD - brass (½” BSP (M) & 1 ½” NPT (M)) VVXD - stainless steel (½” BSP (M) & 1 ½" NPT (M)) VVXE - brass (2” BSP (M) & 2" NPT (M)) VVXE - stainless steel (2” BSP (M) & 2" NPT (M)) Explanation of the 4th number: A is for type VVX15 C is for type VVX20 B is for type VVX25 D is for type VVX32 E is for type VVX40
Factor:
SIKA Systemtechnik GmbH
Company Name
SIKA Systemtechnik GmbH
Address
Struthweg 7-9, D 34260 Kaufungen
Phone
+ 49 5605 803 650

View All Listings by this Company

Print This Approval


#2012341

Range of flow sensors with brass bodies. Maximum working pressure 16.0 bar. Maximum operating temperature 90°C

Section:
1530 Miscellaneous Fittings
WRAS Approval Number:
2012341
Expiry date:
31/12/2025
Size:
¾” BSP (M).
Marking:
Sika, part number and other information on adhesive label on cable. Flow arrow on body
Installation Requirements:
R001
Model:
Flow sensors type series VTY15 Models: VY1545abcdefgh ab:for body material (MA = Brass CW617N-DW, MK = Brass CW724R, K5 = without body, only the internal turbine system) cd: for sensor and signal output (HN = Hall sensor-NPN, 00 = without sensor) ef: for electrical cable connection (various - in combination can be 00…99 or AA…ZZ, examples 05 = 500mm, 12=1200mm, X1=80mm with Molex plug connector) gh: for process connection (A4 = G3/4 male thread, YY = without, only possible with ab = K5) VY1545abyyyyyzz ab: for body material (MA = Brass CW617N-DW, MK = Brass CW724R, K5 = without body, only the internal turbine system) yyyyy: for name of customer (5 digits, e.g. SCHMI, MUELL, …) zz: for consecutive number (2 digits, 01…99)
Manufacturer:
SIKA Systemtechnik GmbH
Company Name
SIKA Systemtechnik GmbH
Address
Struthweg 7-9, D 34260 Kaufungen
Phone
+ 49 5605 803 650

View All Listings by this Company

Print This Approval


#2111301

Range of flow switches with plastic bodies. The VKX15M prefix models are supplied with an inline brass adaptor. The VKX05M prefix models are supplied with a brass adaptor for direct insertion into a pipe. Maximum working pressure 10.0 bar. Maximum operating temperature 100°C.

Section:
1718 Switches
Section Subtitle:
Flow control.
WRAS Approval Number:
2111301
Expiry date:
30/11/2026
Size:
VKX15M prefix models with an inline brass adaptor: ½” BSP (M), ¾” BSP (M), ID 15mm, ID 22mm. VKX05M prefix models with direct insertion brass adaptor: ½” BSP (M), OD 15mm.
Marking:
SIKA, logo and flow arrow on body. Part no, technical data, date of manufacture WWYY on adhesive label attached to cable. Sika on the inline brass adaptor (VKX15M models).
Installation Requirements:
R001
Model:
Type series VKX Model keycode #1: VKXabMcdefghij ab: for design and nominal pipe size: 15 = nominal pipe size of the pipe section, 05 = direct insertion installation in the pipe with threaded adapter. M: magnet version. c: for magnet version: 0…9 = various magnet positions. d: for material of paddle system: P = plastic. e: for electrical output signal: Various - can be 0…9, examples 1 = reedswitch (normally open) closes at increasing flow, 9 = reedswitch (normally closed) opens at decreasing flow. f: for cable and plug version: Various – can be 0…9 or A…Z, examples 0 = PVC-2x0,75 mm², Z = PVC-2x0,5 mm². g: for body material: P = plastic. hi: for process connection: A3 = G1/2 male, A4 = G3/4 male, L3 = internal soldering ends ID 15mm, L4 = internal soldering ends ID 22 mm, R2 = Threaded adapter G1/2 male, D1 = Soldering adapter OD 15 mm. j: for material of pipe section, soldering and threaded adapter: 0 = without, 1 = brass. Model keycode #2: VKXabMcyyyyyzz ab: for design and nominal pipe size: 15 = nominal pipe size of the pipe section, 05 = direct insertion installation in the pipe with threaded adapter. M: magnet version. c: for magnet version: 0…9 = various magnet positions. yyyyy: for name of customer (5 digits, e.g. SCHMI, MUELL, …). zz: for consecutive number (2 digits, 01…99). VKXabMcyyyyyzz are customized versions, but technically identical with VKXabMcdefghij regarding all parts/components in contact with wholesome water.
Factor:
SIKA Systemtechnik GmbH
Company Name
SIKA Systemtechnik GmbH
Address
Struthweg 7-9, D 34260 Kaufungen
Phone
+ 49 5605 803 650

View All Listings by this Company
Manufacturer:
SIKA Dr. Siebert & Kuhn GmbH & Co.KG
Company Name
SIKA Dr. Siebert & Kuhn GmbH & Co.KG
Address
Struthweg 7-9 34260 Kaufungen
Phone
+49 56058030

View All Listings by this Company

Print This Approval


#2111302

Range of flow switches with plastic bodies. The VK308/10/15/20/25/32/40/50M and VKS08/10/15/20/25/32/40/50M prefix models are supplied with an inline brass adaptor. The VK305/306/309M and VKS05/06/09M prefix models are supplied with a brass adaptor for direct insertion into a pipe. Maximum working pressure 10.0 bar. Maximum operating temperature 100°C.

Section:
1718 Switches
Section Subtitle:
Flow control.
WRAS Approval Number:
2111302
Expiry date:
30/11/2026
Size:
VK3xxM/VKSxxM prefix models with an inline brass adaptor: VK308M/VKS08M: ¼” BSP (F). VK310M/VKS10M: ⅜” BSP (F). VK315M/VKS15M: ½” BSP (F), ½” BSP (M), ¾” BSP (M). VK320M/VKS20M: ¾” BSP (F). VK325M/VKS25M: 1” BSP (F). VK332M/VKS32M: 1¼” BSP (F). VK340M/VKS40M: 1½” BSP (F). VK350M/VKS50M: 2” BSP (F). VK305M/306M and VKS05M/06M prefix models with direct insertion brass adaptor: ½” BSP (M). VK309M and VKS09M prefix models with direct insertion brass adaptor: OD 15mm.
Marking:
SIKA, address, model, date of manufacture batch code (WWYY) and other technical information on adhesive label attached to cable (VK3 models) or switch box (VKS models). Sika on the inline brass adaptor (VK3xxM prefix models with an inline brass adaptor only).
Installation Requirements:
R001
Model:
Type series VK3 and VKS. Model keycode #1: VK3abMcdefghij and VKSabMcdefghij. ab: for design and nominal pipe size: 08…50 = nominal pipe size of the pipe section, 05, 06, 09 = direct insertion installation in the pipe with threaded or soldering adapter. M: magnet version. c: for magnet version: 0…9 = various magnet positions. d: for material of paddle system: P = plastic, 5 = brass/stainless steel. e: for electrical output signal: Various - can be 0…9, examples 1 = reedswitch (normally open) closes at increasing flow, 9 = reedswitch (normally closed) opens at decreasing flow. f: for cable and plug version: Various – can be 0…9 or A…Z, examples 0 = PVC-2x0,75 mm², Z = PVC-2x0,5 mm². g: for body material: P = plastic. hi: for process connection: 1I = G1/4 female, 2I = G3/8 female, 3I = G1/2 female, 3A = G1/2 male, 4A = G3/4 male, 4I = G3/4 female, 5I = G1 female, 6I = G1 1/4 female, 7I = G1 1/2 female, 8I = G2 female, 2R = Threaded adapter G1/2 male, 1D = Soldering adapter OD 15 mm. j: for material of pipe section, soldering and threaded adapter: 0 = without, 1 = brass. Model keycode #2: VK3abMcyyyyyzz and VKSabMcyyyyyzz ab: for design and nominal pipe size: 08…50 = nominal pipe size of the pipe section, 05, 06, 09 = direct insertion installation in the pipe with threaded or soldering adapter. M: magnet version. c: for magnet version: 0…9 = various magnet positions. yyyyy: for name of customer (5 digits, e.g. SCHMI, MUELL, …). zz: for consecutive number (2 digits, 01…99). VK3abMcyyyyyzz and VKSabMcyyyyyzz are customized versions, but technically identical with VK3abMcdefghij and VKSabMcdefghij regarding all parts/components in contact with wholesome water.
Factor:
SIKA Systemtechnik GmbH
Company Name
SIKA Systemtechnik GmbH
Address
Struthweg 7-9, D 34260 Kaufungen
Phone
+ 49 5605 803 650

View All Listings by this Company
Manufacturer:
SIKA Dr. Siebert & Kuhn GmbH & Co.KG
Company Name
SIKA Dr. Siebert & Kuhn GmbH & Co.KG
Address
Struthweg 7-9 34260 Kaufungen
Phone
+49 56058030

View All Listings by this Company

Print This Approval


#2112314

Range of flow switches incorporating brass or stainless steel bodies. Maximum working pressure 25.0 bar. Maximum operating temperature 100°C.

Section:
1718 Switches
Section Subtitle:
Flow control.
WRAS Approval Number:
2112314
Expiry date:
31/12/2026
Size:
VH308M/VHS08M prefix models:¼” BSP (F), VH310M/VHS10M prefix models:⅜” BSP (F), VH305M/VHS05M/VHS06M prefix models: ½” BSP (M), VH315M/VHS15M prefix models: ½” BSP (F), ½” BSP (M), ¾” BSP (M), VH320M/VHS20M prefix models: ¾” BSP (F), VH325M/VHS25M prefix models: 1” BSP (F), VH332M/VHS32M prefix models: 1¼” BSP (F), VH340M/VHS40M prefix models: 1½” BSP (F), VH350M/VHS50M prefix models: 2” BSP (F).
Marking:
SIKA logo (Sika), model no., date of manufacture (WWYY) and other technical data on adhesive label on switch head (VHS models) or attached to cable (VH3 models). Flow arrow on switch head.
Installation Requirements:
R001
Model:
Type series VH3 and VHS Model keycode #1: VH3abMcdefghij and VHSabMcdefghij ab: for design and nominal pipe size: 05 (brass or s/steel models), 06 (brass models only) = direct insertion installation in the pipe with threaded adapter. M: magnet version. c: for magnet version: 0…9 = various magnet positions. d: for material of paddle system: 1 = brass, 3 = stainless steel, 5 = brass/stainless steel. e: for electrical output signal various - can be 0…9, examples 1 = reedswitch NO closes at increasing flow, 9 = reedswitch NC opens at decreasing flow) f: for cable and plug version: Various – can be 0…9 or A…Z, examples 0 = PVC-2x0,75 mm², Z = PVC-2x0,5 mm². g: for body material 1 = brass, 3 = stainless steel. hi: for process connection (3A & 4A not available on stainless steel models). 1I = G1/4 female, 2I = G3/8 female, 3I = G1/2 female, 3A = G1/2 male, 4A = G3/4 male, 4I = G3/4 female, 5I = G1 female, 6I = G1 1/4 female, 7I = G1 1/2 female, 8I = G2 female, 2R = Threaded adapter G1/2 male. j: for material of pipe section and threaded adapter: 0 = without, 1 = brass, 3 = stainless steel. Model keycode #2: VH3abMcyyyyyzz and VHSabMcyyyyyzz ab: for design and nominal pipe size: 08…50 = nominal pipe size of the pipe section. 05 (brass or s/steel models), 06 (brass models only) = direct insertion installation in the pipe with threaded adapter. M: magnet version. c: for magnet version: 0…9 = various magnet positions. yyyyy: for name of customer (5 digits, e.g. SCHMI, MUELL, …). zz: for consecutive number (2 digits, 01…99). VH3abMcyyyyyzz / VHSabMcyyyyyzz are customized versions, but technically identical with VH3abMcdefghij / VHSabMcdefghij regarding all parts/components in contact with wholesome water.
Factor:
SIKA Systemtechnik GmbH
Company Name
SIKA Systemtechnik GmbH
Address
Struthweg 7-9, D 34260 Kaufungen
Phone
+ 49 5605 803 650

View All Listings by this Company
Manufacturer:
SIKA Dr. Siebert & Kuhn GmbH & Co.KG
Company Name
SIKA Dr. Siebert & Kuhn GmbH & Co.KG
Address
Struthweg 7-9 34260 Kaufungen
Phone
+49 56058030

View All Listings by this Company

Print This Approval


#2111343

Range of flow sensors with brass or plastic bodies. Flow sensor type series VTY10 (plastic body, G3/4): Maximum working pressure 10.0 bar. Maximum operating temperature 85°C. Flow sensor type series VTY10 (plastic body, Quickfasten OD 22.5mm): Maximum working pressure 10.0 bar. Maximum operating temperature 70°C. Flow sensor type series VTY10 (brass body, G1/2): Maximum working pressure 16.0 bar. Maximum operating temperature 90°C.

Section:
1718 Switches
Section Subtitle:
Flow control.
WRAS Approval Number:
2111343
Expiry date:
30/11/2026
Size:
Brass body: ½” BSP (M). Plastic body: ¾” BSP (M), OD 22.5mm.
Marking:
SIKA, address, model, date of manufacture batch code (WWYY) and other technical info on adhesive label on cable. SIKA and flow arrow on body.
Installation Requirements:
R001
Model:
Type series VTY10 Model keycode #1: VY1030abcdefgh ab: for body material: MA = brass body CW617N-DW, K5 = plastic body. cd: for sensor and signal output HN = Hall sensor-NPN, 00 = without sensor. ef: for electrical cable connection: Various - in combination can be 00…99 or AA…ZZ, examples 05 = 500mm, 12=1200mm, X1=80mm with Molex plug connector. gh: for process connection A3 = G1/2 male thread, A4 = G3/4 male thread, Q1 = quick fasten, YY = without, only possible with ab = K5. Model keycode #2: VY1030abyyyyyzz or VY1030ayyyyyzz ab: for body material: MA = brass body CW617N-DW, K5 = plastic body. Or a: for body material: M = brass body CW617N-DW. yyyyy: for name of customer (5 digits, e.g. SCHMI, MUELL, …). zz: for consecutive number (2 digits, 01…99). VY1030abyyyyyzz and VY1030ayyyyyzz are customized versions, but technically identical with VY1030abcdefgh regarding all parts/components in contact with wholesome water.
Factor:
SIKA Systemtechnik GmbH
Company Name
SIKA Systemtechnik GmbH
Address
Struthweg 7-9, D 34260 Kaufungen
Phone
+ 49 5605 803 650

View All Listings by this Company
Manufacturer:
SIKA Systemtechnik GmbH.
Company Name
SIKA Systemtechnik GmbH.
Address
Lindenallee 1, 34225 Baunatal

View All Listings by this Company

Print This Approval


#2206802

Range of flow sensors with brass or plastic bodies (see model). Maximum working pressure 16.0 bar. Maximum operating temperature 90°C.

Section:
1718 Switches
Section Subtitle:
Flow control.
WRAS Approval Number:
2206802
Expiry date:
29/06/2027
Size:
VY2060MA, MK or M prefix models: 1” BSP (M). VY2060K5 or K prefix models: 24.05mm OD.
Marking:
VY2060MA, MK or M prefix models: SIKA & flow arrow on body; SIKA and date of manufacture (WWYY) on adhesive label on cable. VY2060K5HN or KHN prefix sensor only models: SIKA and date of manufacture (WWYY) on adhesive label on cable. VY2060K5 or K prefix internal turbine models: Sika logo, model and date of manufacture (WWYY) on body.
Installation Requirements:
R001
Model:
Type series VTY20 Model keycode #1: VY2060abcdefgh ab: for body material: MA = brass body CW617N-DW, MK = brass body CW724R, K5 = plastic body (without turbine body, only the internal turbine system) cd: for sensor and signal output HN = Hall sensor-NPN, 00 = without sensor. ef: for electrical cable connection: Various - in combination can be 00…99 or AA…ZZ, examples 05 = 500mm, 12=1200mm, X1=80mm with Molex plug connector. gh: for process connection A5 = G1 male thread, YY = without, only possible with ab = K5. Model keycode #2: VY2060abyyyyyzz or VY2060ayyyyyzz ab: for body material: MA = brass body CW617N-DW, MK = brass body CW724R, K5 = plastic body (without turbine body, only the internal turbine system) Or a: for body material: M = brass body CW617N-DW. K = plastic body (without pipe section, only the internal turbine system) yyyyy: for name of customer (5 digits, e.g. SCHMI, MUELL, …). zz: for consecutive number (2 digits, 01…99). VY2060abyyyyyzz and VY2060ayyyyyzz are customized versions, but technically identical with VY2060abcdefgh regarding all parts/components in contact with wholesome water.
Factor:
SIKA Systemtechnik GmbH
Company Name
SIKA Systemtechnik GmbH
Address
Struthweg 7-9, D 34260 Kaufungen
Phone
+ 49 5605 803 650

View All Listings by this Company
Manufacturer:
SIKA Systemtechnik GmbH.
Company Name
SIKA Systemtechnik GmbH.
Address
Lindenallee 1, 34225 Baunatal

View All Listings by this Company

Print This Approval


#2309314

Range of flow sensors with brass or plastic bodies (see model). Maximum working pressure 16.0 bar. Maximum operating temperature 90°C.

Section:
1718 Switches
Section Subtitle:
Flow control.
WRAS Approval Number:
2309314
Expiry date:
30/09/2028
Size:
VY2590MA prefix models: 1¼” BSP (M). VY2590K5 prefix models: 27.88mm OD.
Marking:
VY2590MA prefix models: Sika logo and flow arrow on brass body. Sika logo, model number and other technical information on adhesive label on cable. VY2590K5 prefix models: Sika logo, model number (VK2590K50000YY), flow arrow and date of manufacture (WW/YY) on plastic turbine body.
Installation Requirements:
R001
Model:
Type series VTY25 Model keycode #1: VY2590abcdefgh ab: for body material: MA = brass body CW617N-DW, K5 = plastic body (without turbine body, only the internal turbine system) cd: for sensor and signal output HN = Hall sensor-NPN, 00 = without sensor. ef: for electrical cable connection: Various - in combination can be 00…99 or AA…ZZ, examples 05 = 500mm, X1=80mm with Molex plug connector. gh: for process connection A6 = G1¼ male thread - nominal size DN25, YY = without, only possible with ab = K5. VY2590MAHNefA6 (Flow sensor with brass turbine body) ef: for electrical cable connection: Various - in combination can be 00…99 or AA…ZZ, examples 05 = 500mm, X1=80mm with Molex plug connector. VY2590K50000YY (Only internal turbine) Model keycode #2: VY2590abyyyyyzz ab: for body material: MA = brass body CW617N-DW, K5 = plastic body (without turbine body, only the internal turbine system) yyyyy: for name of customer (5 digits) zz: for consecutive number (2 digits, 01…99). VY2590abyyyyyzz are customized versions, but technically identical with VY2590abcdefgh regarding all parts/components in contact with wholesome water.
Factor:
SIKA Systemtechnik GmbH.
Company Name
SIKA Systemtechnik GmbH.
Address
Lindenallee 1, 34225 Baunatal

View All Listings by this Company
Manufacturer:
SIKA Systemtechnik GmbH
Company Name
SIKA Systemtechnik GmbH
Address
Struthweg 7-9, D 34260 Kaufungen
Phone
+ 49 5605 803 650

View All Listings by this Company

Print This Approval


Show Per Page
5102050Show All

Back To Directory Sections

Page of 1

We use cookies to give you the best possible experience with WRAS. Some are essential to provide website functions and ensure the website is secure. We also use cookies to help us understand how people use the site and to make improvements. Click "Accept All" to enable recommended settings or click "Manage cookies" to adjust your settings. For more details, see our Cookie Policy.