Clearwater Products Approvals


#1910358

Range of single hole, single outlet (swivel) combination tap assemblies with brass bodies (with various finishes) having ceramic cartridge headworks and single lever operating members. The spout outlet incorporates a plastic aerator. Maximum working pressure 8 bar. Maximum operating temperature 60°C

Section:
0470 Combination Tap Assemblies
Section Subtitle:
Single hole, metal, single outlet, swivel. Taps used in high risk installations, such as kitchen sinks, are considered to be a fluid category 5 risk. Backflow protection is usually provided in the form of an AUK3 tap gap. Where an AUK3 tap gap cannot be maintained, for example where the tap gap is compromised as a result of:- • the tap being lowered in any way; • adjustment to the spout which reduces the distance between the tap outlet and spillover level of the sink; • or the operation of a pull out hose attachment; alternative fluid category 5 backflow protection is required.
WRAS Approval Number:
1910358
Expiry date:
31/10/2024
Marking:
Clearwater on main body
Installation Requirements:
R001 R006 R010
Model:
ZO2AB, ZO2BV, ZO2RC, ZO3AB, ZO3BV, ZO3RC, ZO4AB, ZO4BV & ZO4RC Where: AB=Laskine RC=Wire drawing copper BV=ORB black
Factor:
Clearwater Products
Company Name
Clearwater Products
Address
Unit 5603 Shannon Place, Tewkesbury Business Park, Tewkesbury
Postcode
GL20 8SL
Phone
01684 299555

View All Listings by this Company

Print This Approval


#2011024

Range of single hole, single outlet (swivel) combination tap assemblies with brass bodies (various finishes), incorporating either a ceramic cartridge headwork (models SH2CP/SH2BN), or quarter turn ceramic disc headwork (all other models) and single lever operating members. The spout outlets of all models incorporate a plastic aerator. Maximum working pressure 8.0 bar. Maximum operating temperature 60°C.

Section:
0470 Combination Tap Assemblies
Section Subtitle:
Single hole, metal, single outlet, swivel. Taps used in high risk installations, such as kitchen sinks, are considered to be a fluid category 5 risk. Backflow protection is usually provided in the form of an AUK3 tap gap. Where an AUK3 tap gap cannot be maintained, for example where the tap gap is compromised as a result of:- • the tap being lowered in any way; • adjustment to the spout which reduces the distance between the tap outlet and spillover level of the sink; • or the operation of a pull out hose attachment; alternative fluid category 5 backflow protection is required.
WRAS Approval Number:
2011024
Expiry date:
30/11/2025
Size:
M10
Marking:
Clearwater on base of body.
Installation Requirements:
R001 R006 R010
Model:
Rococo: RO81062CP - Chrome plating. RO81062BN - Brush nickel. RO81062AB - Brush gold. RO81062BV - ORB. RO81062RC - Brush brass. Savita: SA2CP - Chrome plating. SA2BN - Brush nickel. Tutti: TU81073CP - Chrome plating. TU81073BS - Brush nickel. TU81073AB - Brush gold. TU81073BV - ORB. TU81073RC - Brush brass. Vitro: VITCP - Chrome plating. VITBS - Brush nickel.
Factor:
Clearwater Products
Company Name
Clearwater Products
Address
Unit 5603 Shannon Place, Tewkesbury Business Park, Tewkesbury
Postcode
GL20 8SL
Phone
01684 299555

View All Listings by this Company

Print This Approval


#2201078

Range of two hole, single outlet (swivel) combination tap assemblies (brass bodies, various finishes - see model), incorporating quarter turn ceramic disc headworks with single lever operating members. The spout outlet incorporates a plastic flow straightener. This product is supplied with metal backnuts. Maximum working pressure 5.0 bar. Maximum working temperature 60°C.

Section:
0550 Combination Tap Assemblies
Section Subtitle:
Two hole, metal, single outlet, swivel. Taps used in high risk installations, such as kitchen sinks, are considered to be a fluid category 5 risk. Backflow protection is usually provided in the form of an AUK3 tap gap. Where an AUK3 tap gap cannot be maintained, for example where the tap gap is compromised as a result of: • the tap being lowered in any way; • adjustment to the spout which reduces the distance between the tap outlet and spillover level of the sink; • or the operation of a pull out hose attachment; alternative fluid category 5 backflow protection is required.
WRAS Approval Number:
2201078
Expiry date:
31/01/2027
Size:
½” BSP (M)
Marking:
Clearwater on front of body
Installation Requirements:
R001 R006 R010
Model:
ELB10CP, ELB10BN, ELB10BB, ELB10BZ & ELB10BC COMBINATION TAP ASSEMBLIES
Factor:
Clearwater Products
Company Name
Clearwater Products
Address
Unit 5603 Shannon Place, Tewkesbury Business Park, Tewkesbury
Postcode
GL20 8SL
Phone
01684 299555

View All Listings by this Company

Print This Approval


#2205097

Range of single hole, single outlet (swivel) combination tap assemblies with brass bodies (various finishes), incorporating a ceramic cartridge headwork with a single lever operating member. This product also incorporates an additional spring-loaded quarter turn ceramic disc headwork with a single lever operating member for filtered cold water discharged from the spout outlet. The spout outlet incorporates a plastic aerator. Maximum working pressure 5.0 bar. Maximum operating temperature 65°C.

Section:
0470 Combination Tap Assemblies
Section Subtitle:
Single hole, metal, single outlet, swivel. Taps used in high risk installations, such as kitchen sinks, are considered to be a fluid category 5 risk. Backflow protection is usually provided in the form of an AUK3 tap gap. Where an AUK3 tap gap cannot be maintained, for example where the tap gap is compromised as a result of:- • the tap being lowered in any way; • adjustment to the spout which reduces the distance between the tap outlet and spillover level of the sink; • or the operation of a pull out hose attachment; alternative fluid category 5 backflow protection is required.
WRAS Approval Number:
2205097
Expiry date:
31/05/2027
Note:
R009 only applies to models with PEX lined hoses
Size:
Stainless steel braided PEX or EPDM lined flexible hose assemblies incorporating ½” BSP captive nut end connections (see models).
Marking:
Clearwater on front of body.
Installation Requirements:
R001 R006 R007 R009 R010
Model:
Models with PEX lined hoses: MAE2CP Chrome plated MAE2BN Brushed MAE2MB Black colour MAE3CP Chrome plated MAE3BN Brushed MAE3MB Black colour MAE3KCP Chrome plated MAE3KBN Brushed MAE3KMB Black colour MAE3KBC-B Brushed Brass MAE2KBC Black MAE2KCP Chrome plated MAE2KBN Brushed MAE2KMB Black colour MAE3KBB Brushed Brass MAE2KBB Brushed Copper Models with EPDM lined hoses: MAE2CP Chrome plated MAE2BC Black colour MAE2BB Chrome plated MAE3BC Brushed MAE3BB Brushed Black HOT1CP Chrome plated HOT1BN Brushed HOT2CP Black colour
Factor:
Clearwater Products
Company Name
Clearwater Products
Address
Unit 5603 Shannon Place, Tewkesbury Business Park, Tewkesbury
Postcode
GL20 8SL
Phone
01684 299555

View All Listings by this Company

Print This Approval


#2301317

Range of single hole, single outlet (swivel) combination tap assemblies (brass bodies - various finishes) incorporating ceramic disc headwork with single lever operating members. The spout outlets incorporate a plastic aerator. Maximum working pressure 5.0 bar.

Non-metallic materials and components comply with BS6920 at 80°C

Section:
0470 Combination Tap Assemblies
Section Subtitle:
Single hole, metal, single outlet, swivel. Taps used in high risk installations, such as kitchen sinks, are considered to be a fluid category 5 risk. Backflow protection is usually provided in the form of an AUK3 tap gap. Where an AUK3 tap gap cannot be maintained, for example where the tap gap is compromised as a result of:- • the tap being lowered in any way; • adjustment to the spout which reduces the distance between the tap outlet and spillover level of the sink; • or the operation of a pull out hose attachment; alternative fluid category 5 backflow protection is required.
WRAS Approval Number:
2301317
Expiry date:
31/01/2028
Size:
Stainless steel braided PEX lined flexible hose assemblies incorporating ½” BSP captive nut end connections.
Marking:
Clearwater (RO81062CP) or CW (LOR10CP) on body.
Installation Requirements:
R001 R040
Model:
RO81062CP, LOR10CP. Models added April 2023; ROC2MB ROC2WH ROC2AB ROC2RC ROC2BN LOR10MB LOR10WH LOR10AB LOR10RC LOR10BN
Factor:
Clearwater Products
Company Name
Clearwater Products
Address
Unit 5603 Shannon Place, Tewkesbury Business Park, Tewkesbury
Postcode
GL20 8SL
Phone
01684 299555

View All Listings by this Company

Print This Approval


#2301361

Range of single hole, single outlet (swivel) combination tap assemblies (chromium plated brass) incorporating ceramic disc headwork with single lever operating members. The spout outlets incorporate a plastic aerator. Maximum working pressure 5.0 bar.

Non-metallic materials and components comply with BS6920 at 80°C

Section:
0470 Combination Tap Assemblies
Section Subtitle:
Single hole, metal, single outlet, swivel. Taps used in high risk installations, such as kitchen sinks, are considered to be a fluid category 5 risk. Backflow protection is usually provided in the form of an AUK3 tap gap. Where an AUK3 tap gap cannot be maintained, for example where the tap gap is compromised as a result of:- • the tap being lowered in any way; • adjustment to the spout which reduces the distance between the tap outlet and spillover level of the sink; • or the operation of a pull out hose attachment; alternative fluid category 5 backflow protection is required.
WRAS Approval Number:
2301361
Expiry date:
31/01/2028
Size:
Stainless steel braided PEX lined flexible hose assemblies incorporating ½” BSP captive nut end connections.
Marking:
CW on body.
Installation Requirements:
R001 R040
Model:
LEITH
Factor:
Hafele Ireland Limited
Company Name
Hafele Ireland Limited
Address
Kilcoole Ind Est Kilcoole Co Wicklow
Postcode
A63 KC58

View All Listings by this Company
Manufacturer:
Clearwater Products
Company Name
Clearwater Products
Address
Unit 5603 Shannon Place, Tewkesbury Business Park, Tewkesbury
Postcode
GL20 8SL
Phone
01684 299555

View All Listings by this Company

Print This Approval


Show Per Page
5102050Show All

Back To Directory Sections

Page of 1

We use cookies to give you the best possible experience with WRAS. Some are essential to provide website functions and ensure the website is secure. We also use cookies to help us understand how people use the site and to make improvements. Click "Accept All" to enable recommended settings or click "Manage cookies" to adjust your settings. For more details, see our Cookie Policy.