Range of spring loaded, resilient trim, in-line check valve cartridges with plastic guide, stem and body with silicone or EPDM 'O'-rings. Maximum working pressure 16.0 bar. Maximum operating temperature 85°C for models 30.4010.0 and 40.4011.0. Maximum operating temperature 60°C for models 30.4043.0 and 30.4094.0.
Adaptor, with DZR brass body (chrome plated), which incorporates a single check valve cartridge verified by test (as suitable for backflow protection against Fluid Category 2). Maximum working pressure 16.0 bar. Maximum operating temperature 85°C.
Single check valve assembly with a brushed nickel coated DZR brass body, incorporating a screwdriver operated isolation valve and EPDM ‘O’ rings. Maximum working pressure 10.0 bar. Maximum operating temperature 85ºC.
Non-verifiable double check valve assembly incorporating DZR brass (chrome plated) body two spring loaded, resilient trim in-line check valve cartridges & a drain port located between the cartridges. Maximum working pressure 10.0 bar. Maximum operating temperature 65°C.
Range of non verifiable double check valve assemblies consisting of two spring loaded resilient trim in-line check valve cartridges housed in a DZR brass body. The products incorporate a drain port between the cartridges. Maximum working pressure 16.0 bar. Maximum operating temperature 85°C.
Range of non-verifiable double check valve assemblies, consisting of two spring loaded resilient trim in-line check valve cartridges housed in DZR brass bodies (brushed chrome plated) with a drain port located between the cartridges either at the top or bottom. Models incorporate an isolation valve with either lever or butterfly handles. Maximum working pressure 10.0 bar. Maximum operating temperature 85°C.
Range of single hole, single outlet (fixed) over the rim (swivel nozzle) bidet combination tap assemblies (chromium plated brass) incorporating a ceramic cartridge headwork and either single lever or dome type operating members. The spout outlet incorporates a plastic aerator. Maximum working pressure 5.0 bar. Maximum operating temperature 85°C
Range of quarter turn ceramic disc headworks with brass bodies, EPDM rubber ‘O’-rings and silicone rubber washers. Maximum working pressure 10.0 bar. Maximum operating temperature 85°C.
Range of ceramic cartridge headworks with a plastic body and EPDM ‘O’-rings to be inserted into specifically dimensioned bodies. Maximum working pressure 10.0 bar. Maximum operating temperature 85°C.
Range of ceramic disc headworks with brass bodies and EPDM seals. Maximum working pressure 16.0 bar. Maximum operating temperature 85°C.
Range of ceramic cartridge, ceramic disc, non-rising spindle, or push button cartridge (see models) headworks to be installed in specifically dimensioned bodies. Maximum working pressure 25.0 bar. Maximum operating temperature 65°C.
Range of ceramic cartridge headworks with NBR ‘O’-rings and silicone seals or silicone ‘O’-rings and seals (depending on model). For insertion into specifically dimensioned tap assemblies. Maximum working pressure 10.0 bar. Models 35H-F, 40D-F & 40H-F have a maximum operating temperature of 60°C. All other models have a maximum operating temperature of 85°C.
Range of CA43 thermostatic cartridges incorporating plastic bodies and stainless steel filters. For insertion into specifically dimensioned bodies. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.
Range of single hole, single outlet (fixed) combination tap assemblies with brass bodies (various finishes), incorporating ceramic cartridge headworks with single lever operating members. The spout outlets incorporate a plastic aerator. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.
Range of single hole, single outlet (fixed) combination tap assemblies (chromium plated brass) incorporating a ceramic cartridge headwork with a single lever operating member. The spout outlets incorporate either a plastic flow straightener or aerator. The product is supplied with a click type waste. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.
Range of single hole, single outlet (fixed) combination tap assemblies (chromium plated brass), incorporating a ceramic cartridge headwork with either a dome type or single lever operating members. The spout outlet incorporates a plastic aerator. Maximum working pressure is 5.0 bar. Maximum operating temperature 60°C.
Single hole, single outlet fixed combination tap assembly (chromium plated brass), incorporating a ceramic cartridge headwork with a single lever operating member. The spout outlet incorporates a plastic flow straighteners Maximum operating pressure 5.0 bar. Maximum operating temperature 60°C
Single hole, single outlet fixed combination tap assemblies (chromium plated brass), incorporating a ceramic cartridge headwork with a single lever operating. The spout outlet incorporates a plastic flow straightener. Product is supplied with a pop up waste. Maximum operating pressure 5.0 bar. Maximum operating temperature 60°C
Range of single hole, single outlet (fixed) combination tap assemblies (in black or chrome finishes) with brass bodies. Incorporating ceramic cartridge headworks, and single lever operating members. The spout outlet incorporates a plastic aerator. Some models are supplied with a pop-up waste. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.
Single hole, single outlet (fixed) combination tap assembly incorporating ceramic cartridge headwork and single lever operating member. The spout outlet incorporates a plastic aerator. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.
Range of single hole, single outlet (fixed) combination tap assemblies with brass bodies (various finishes) incorporating ceramic cartridge headworks and single lever operating members. The spout outlets incorporate a plastic aerator. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.
Range of single hole, single outlet (fixed) combination tap assemblies incorporating ceramic cartridge headworks and single lever operating members. The spout outlets incorporate a plastic aerator. Models 53003 and 53005 are supplied with a pop-up waste. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.
Range of single hole, single outlet fixed combination tap assemblies (chromium plated brass), incorporating a ceramic cartridge headwork with a single lever operating members. The spout outlet incorporates a plastic flow straightener. Products are supplied with a click type waste. Maximum operating pressure 5.0 bar. Maximum operating temperature 60°C
Range of single hole, single outlet (fixed) combination tap assemblies with brass bodies (chrome plated), incorporating a ceramic cartridge headwork with a single lever operating member. The spout outlets of models SAVV2313 & SEV313 incorporate a plastic aerator, model SPA2113/EX incorporates a stainless steel filter. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.
Single hole, single outlet (fixed) electronically controlled tap assemblies (chromium plated brass). Flow is controlled by a solenoid valve activated via infra-red sensor. Solenoid housing incorporated a filter mesh. The product is supplied with a stainless steel braided EPDM lined flexible hose assembly to connect between the tap body and the solenoid valve. The spout outlets incorporate a plastic aerator. Maximum working pressure 5.0 Bar. Maximum operating temperature 60°C.
Range of single hole, single outlet (fixed) combination tap assemblies (brass bodies - various finishes), incorporating a ceramic cartridge headwork with a single lever (Absolute range) or dome type (Engineer & Illustrious range) operating member. The spout outlet incorporates a plastic aerator. Maximum working pressure 3.0 bar. Maximum operating temperature 60.0°C
Range of single hole, single outlet (fixed) combination tap assemblies (chromium plated brass) incorporating a ceramic cartridge headwork with single lever operating member. The spout outlets incorporate a plastic aerator and the inlets incorporate a stainless steel strainer. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.
Range of single hole, single outlet (fixed) combination tap assemblies (chromium plated brass), incorporating a ceramic cartridge headwork with a single lever operating member. The spout outlet incorporates a plastic flow straightener with an optional aerator. Fittings are supplied with a pop-up waste. Maximum working pressure 5.0 Bar. Maximum operating temperature 60°C.
Floor mounted, single outlet (fixed) combination tap assembly (chromium plated brass) incorporating a ceramic cartridge headwork with a single lever operating member and a self-cancelling diverter to shower outlet. The shower outlet incorporates an approved check valve cartridge however, the complete product has not been fully tested to demonstrate it provides backflow protection. The spout outlet incorporates a plastic aerator. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.
Range of single hole, single outlet (fixed) combination tap assembly with a brass body (various finishes), incorporating a ceramic cartridge headwork and single lever operating member with self- cancelling diverter to shower outlet. The spout outlet incorporates a plastic aerator. The diverter outlet incorporates an approved check valve cartridge however, the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.
Range of single hole, single outlet (swivel) combination tap assemblies with brass bodies (various finishes), incorporating ceramic cartridge headworks and single lever operating members. The spout outlet incorporates a plastic aerator. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.
Single hole, single outlet (swivel) combination tap assembly (chromium plated brass) incorporating quarter turn ceramic disc headwork with single lever operating members. The spout outlet incorporates a plastic aerator. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.
Range of single hole, single outlet (fixed) combination tap assemblies (chromium plated brass), incorporating ceramic cartridge headworks and single lever operating members. The spout outlets incorporate a plastic aerator. Model 1002137653_N199998998 is supplied with a pop up waste. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.
Single hole, single outlet (swivel) combination tap assembly (chromium plated brass), incorporating a ceramic cartridge headwork with a single lever operating member. The spout outlet incorporates a plastic aerator. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.
Single hole, wall mounted single outlet (swivel) combination tap assembly (chromium plated brass). Incorporating arising spindle headworks and cross top operating member. Maximum working pressure 8.6 bar. Maximum operating temperature 85°C.
Single hole, single outlet (swivel) combination tap assembly (chromium plated brass), incorporating ceramic cartridge headwork and single lever operating member. The spout outlet incorporates a plastic aerator. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.
Range of single hole, single outlet (swivel) combination tap assemblies (chromium plated brass), incorporating ceramic cartridge headworks and single lever operating members. The spout outlet incorporates a plastic aerator. The inlets incorporate an approved check valve cartridge, however, the complete product has not been fully tested to demonstrate it provides backflow protection Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.
Range of single hole, single outlet (swivel) combination tap assemblies (chromium plated brass). Incorporating ceramic cartridge headworks and single lever operating members. The spout outlet incorporates a plastic aerator. Maximum working pressure 6.0 bar. Maximum operating temperature 60°C.
Single hole, single outlet (swivel) combination tap assembly (chromium plated brass), incorporating quarter turn ceramic disc headwork with single lever operating members. The spout outlet incorporates a plastic flow straightener. Maximum working pressure 10.0 bar. Maximum working temperature 60°C.
Range of single hole, single outlet (swivel) combination tap assemblies with brass bodies (various finishes), incorporating either a ceramic cartridge headwork (models SH2CP/SH2BN), or quarter turn ceramic disc headwork (all other models) and single lever operating members. The spout outlets of all models incorporate a plastic aerator. Maximum working pressure 8.0 bar. Maximum operating temperature 60°C.
Range of single hole, double outlet (swivel) combination tap assemblies with brass bodies (various finishes). Incorporating a non-rising spindle headwork with a dome type operating members. Maximum working pressure 10.0 bar. Maximum operating temperature 65°C.
Two hole, single outlet (fixed) combination tap assembly (chromium plated brass & matt black finishes) incorporating quarter turn ceramic disc headwork with single lever operating members. The spout outlets incorporate a metal strainer and either a plastic aerator or alternative flow straightener. The product is supplied with metal backnuts. Maximum working pressure 10.0 bar. Maximum operating temperature 70°C.
Range of deck mounted, two hole, single outlet (fixed) combination tap assemblies with brass bodies (various finishes), incorporating quarter turn ceramic disc headworks with single lever operating members or non-rising spindle headworks with cross top operating members (model CR26 & CR26/501). The spout outlet incorporates a plastic flow straightener (models CR26 & CR26/501 do not incorporate a flow straightener). The products are supplied with plastic backnuts. Maximum working pressure 10.0 bar. Maximum operating temperature 65°C.
Range two hole, single outlet (fixed) combination tap assembly (chromium plated brass), incorporating quarter turn ceramic disk headworks with single lever operating member. The spout outlet incorporates a plastic flow straightener. The product is supplied with plastic (model VSN208) metal (model DAR108) backnuts. Maximum working pressure 6.0 bar. Maximum operating temperature 60°C.
Range of two hole, single outlet (fixed) combination tap assemblies (various finishes). Incorporating quarter turn ceramic disc headworks with single lever, dome or cross top operating members and manual diverters to shower outlets. The spout outlets incorporate plastic flow straighteners. This approval includes a hose, handset and wall bracket and the products are supplied with plastic backnuts. Maximum working pressure 6.0 bar. Maximum operating temperature 60°C.
Range of deck Mounted bar type thermostatic combination tap assemblies (chromium plated brass), incorporating a ½ turn ceramic disc headwork controlling the flow with either dome type (AR2 THBSM C & BWY AR2 THBSM C) or single lever (AR2 THLBSM C) operating members. The temperature is controlled independently via a thermostatic cartridge with either dome type (AR2 THBSM C & BWY AR2 THBSM C) or single lever (AR2 THLBSM C) operating members incorporating a manual override button. The product also incorporates a manual diverter between the spout outlet and shower outlet. The inlets incorporate a stainless steel strainer and an approved check valve cartridge however, the complete product has not been fully tested to demonstrate it provides backflow protection. The spout outlet incorporates a stainless steel strainer and a plastic flow straightener. Maximum working pressure 10.0 bar. Maximum operating temperature 65°C.
Range of wall mounted two-hole, single outlet (fixed) bath shower mixers with brass bodies (various finishes), incorporating a manual diverter controlling and diverting the flow between the spout outlet and an overhead shower. Temperature is controlled independently via a thermostatic cartridge with dome type operating member with manual override button. The spout outlets incorporate a plastic aerator. Each inlet incorporates an approved check valve cartridge, however, the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.
Range of two-hole, single outlet (fixed) combination tap assemblies (chromium plated brass), incorporating three quarter turn ceramic disc headworks controlling the flow and temperature with cross top operating members and a manually operated diverter to shower outlet with cross top operating members. Model T2DB is supplied with a shower handset and hose and model B2TDS is supplied with a shower pipe and arm. The spout outlets incorporate a plastic aerator or flow straightener. Products are supplied with metal backnuts. The inlets incorporate an approved check valve cartridge however, the complete products have not been fully tested to demonstrate it provides backflow protection Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.
Wall mounted, two-hole, single outlet (fixed) combination tap assembly (chromium plated brass) incorporating quarter turn ceramic disc headworks controlling the temperature with cross top operating members and a manually operated diverter to shower outlet controlling the flow with cross top operating members. The product is supplied with a shower pipe and arm. The spout outlets incorporate a plastic aerator or flow straightener. The inlets incorporate an approved check valve cartridge, however, the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.
Range of two hole, single outlet (fixed) combination tap assemblies (various finishes). Incorporating ceramic disc headworks, single lever operating members and self-cancelling diverter to shower outlet. The spout outlet incorporates a plastic flow straightener. The products are supplied with a shower hose, shower handset and plastic back nuts. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.
Two-hole, single outlet (fixed) combination tap assembly (chromium plated brass), incorporating quarter turn ceramic disc headwork with single lever operating members and a self-cancelling diverter to shower outlet. The spout outlet incorporates a plastic flow straightener and the product is supplied with a shower hose, shower handset and metal backnuts Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.
Two-hole, single outlet (fixed) combination tap assembly (chromium plated brass), incorporating quarter turn ceramic disc headwork with single lever operating members and a self-cancelling diverter to shower outlet. The spout outlet incorporates a plastic flow straightener. The product is supplied with a shower hose, shower handset and metal backnuts. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.
Two hole, single outlet (fixed) combination tap assembly (chromium plated brass), incorporating ceramic disc headworks with single lever operating members and a self-cancelling diverter to the shower outlet. The spout outlet incorporates a plastic flow straightener or optional aerator. The product is supplied with a shower hose, shower handset and metal backnuts. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.
Range of wall mounted two hole, single outlet (fixed) combination tap assemblies (chromium plated brass), incorporating a ceramic cartridge headworks with single lever operating member and self-cancelling diverter to shower outlet. The inlets incorporate a stainless steel strainer and an approved check valve cartridge, however, the complete product has not been fully tested to demonstrate it provides backflow protection. The spout outlet incorporates a plastic aerator. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.
Two hole, single outlet (fixed) combination tap assembly brass body(in various finishes), incorporating quarter turn ceramic disc headwork with single lever operating members and a self-cancelling diverter to shower outlet. The inlet to the shower handset incorporates an approved check valve cartridge, however, the complete product has not been fully tested to demonstrate it provides backflow protection. The spout outlet incorporates a plastic flow straightener and the product is supplied with a shower hose, shower handset and plastic backnuts. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.
Deck mounted, two-hole, single outlet (fixed) combination tap assembly (chromium plated brass) incorporating quarter turn ceramic disc headworks with single lever operating members and a self-cancelling diverter to the shower outlet. The spout outlet incorporates a plastic flow straightener or an optional aerator. The product is supplied with a shower hose, shower handset and metal backnuts. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.
Range of wall mounted, two-hole, single outlet (swivel) combination tap assemblies (chromium plated brass), incorporating ceramic cartridge headwork with single lever operating members. The spout outlets incorporate a plastic flow straightener. The inlet offset unions incorporate a servicing valve and the inlets to the taps incorporate a plastic flow restrictor. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.
Range of deck mounted two hole, double outlet (swivel) combination tap assemblies with brass bodies (various finishes), incorporating quarter turn ceramic disc (DLV305B, DLT305B) or rising spindle (CR305 “Bridge”, CR305/501 “Bridge” & GEO305) headworks. Models GEO305, DLT305B and DLV305B incorporate single lever type operating members. Models CR305 and CR305/501 incorporate cross top operating members. The products are supplied with plastic back nuts. Maximum operating pressure 10.0 bar. Maximum operating temperature 65°C.
Wall mounted two hole, double outlet (swivel) combination tap assembly (chromium plated brass) with quarter turn ceramic disc headworks and single lever type operating members. The product is supplied with plastic back nuts. Maximum operating pressure 10.0 bar. Maximum operating temperature 65°C.
Two hole, wall mounted, double outlet (swivel) combination tap assembly (chromium plated brass). Incorporating rising spindle headworks on the tap body controlling the supply to the pull out hand held pre rinse outlet. An additional rising spindle headwork with a cross top operating member controls the flow to the spout outlet. Maximum working pressure 8.6 bar. Maximum operating temperature 85°C.
Range of three hole, metal, single outlet (fixed) combination tap assemblies available with various finishes (see models). Incorporating quarter turn ceramic disc headwork with various operating members (see models). The spout outlet incorporates a plastic aerator. Products are supplied with metal backnuts & lever type pop-up waste. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.
Three-hole, single outlet, fixed combination tap assembly with a brass body (various finishes), incorporating quarter turn ceramic disc headwork with single lever operating members. The spout outlets incorporate a plastic aerator and the products are supplied with lever type pop-up waste and metal backnuts. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.
Range of three-hole, concealed, metal, single outlet (fixed) combination tap assemblies (chromium plated brass) incorporating quarter turn ceramic disc headwork with wheel, dome, cross top or single lever operating members. The spout outlet comes in various lengths and incorporates a plastic aerator. Maximum working pressure 3.0 bar. Maximum operating temperature 60°C.
Range of concealed wall mounted bath shower mixers (brass body) incorporating a manual diverter to bath or shower handset. Flow is controlled by cartridge headworks using single lever type or dome operating members. Temperature is independently controlled via a single lever or dome type operating member incorporating a manual override button. Manual diverter is also controlled by single lever or dome operating members. The spout outlets incorporate a plastic aerator. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.
Two hole, single outlet (swivel) combination tap assembly (chromium plated brass), incorporating non-rising spindle headwork with cross top operating members and manually operated diverter to shower outlet. The spout outlet incorporates a plastic flow straightener (optional aerator is also supplied) and the product is supplied with a shower hose, shower handset and metal backnuts. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.
Wall mounted bath spout incorporating a brass body (various finishes) and a plastic aerator. Maximum operating temperature 60°C.
Range of spout outlets incorporating brass bodies and NBR ‘O’-rings. The spout outlets incorporate a plastic flow straightener. Models AX-SIR-140/RO/DIV and AX-BOK-140/SQ/DIV incorporate a self-cancelling diverter. Maximum operating temperature 60°C.
`Wellmate` range of expansion vessels with plastic bodies and rubber diaphragms Maximum working pressure 8.6 Bar, cold water use only.
‘Purity’ range of plastic filter heads with EPDM ‘O’-rings. Maximum working pressure 8.6 bar. Cold water use only.
Uponor S-Press press fittings, Uni-X & Uni-C compression fittings for use with Uponor MLC pipe. Maximum working pressure 10.0 bar, maximum operating temperature 70°C.
‘ISR’ range of copper, DZR brass or gunmetal capillary, lead free solder ring and threaded fittings for use with copper pipe. For above ground use only. Maximum working pressure 16.0 bar. Maximum working temperatures 99°C.
‘CB ISR’ range of capillary fittings with internal solder rings, DZR brass or gunmetal capillary, lead free solder ring and threaded fittings for use with copper pipe. For above ground use only. Maximum working pressure 16.0 bar. Maximum working temperatures 99°C.
Range of copper and bronze capillary brazed fittings for use with copper pipe manufactured to EN1057:2006 +A1:2010. Maximum pressure 10.0 Bar (54mm up to and including 108mm) Maximum pressure 2.0 Bar (Over 108mm up to and including 159mm) Maximum operating temperature 100°C.
Range of press fittings incorporating copper or copper alloy bodies and EPDM O’-rings for use with copper tube to EN1057. Maximum working pressure 16.0 bar. Maximum operating temperature 85°C.
Range of end feed copper fittings for use with copper tube. Maximum working pressure 16.0 bar. Maximum operating temperature 95°C.
Range of stainless-steel plate heat exchangers with copper brazing. Maximum working pressure 30.0 Bar. Maximum operating temperature 100°C.
Range of copper brazed stainless-steel heat exchangers. Maximum working pressure 30.0 bar. Maximum operating temperature 100°C.
Range of stainless steel, copper brazed plate type heat exchangers. Maximum working pressure 30.0 bar. Maximum operating temperature 100°C.
Electronically controlled heat interface units (HIU) with twin stainless-steel plate heat exchangers providing space heating and instantaneous hot water. The cold inlet supply to the plate heat exchanger incorporates an isolation valve. The space heating circuit incorporates an expansion vessel and a pressure relief valve (set at 3.0 bar). The inlet and outlet of all circuits incorporates lever operated spherical valves with brass bodies. 274.xx9x.696 models all have the following additional items over the 274.xx1x.696 models: Heatmeter on the primary circuit, a flushing bypass between the primary and space heating circuits and a safety relief valve (set at 10.0 bar) on the cold supply to the heat exchanger of the domestic hot water circuit. Maximum working pressures and operating temperatures: Primary: 16.0 bar and 90˚C. Domestic hot water (DHW): 9.5 bar and 60˚C. Secondary (space heating): 2.5 bar and 85˚C.
Uponor Combi Port range of indirect heat interface units providing heating and instantaneous hot water. The heating system incorporates an expansion vessel and pressure relief valve (set at 3.0 bar).Some units have optional ball valve sets. Primary side heating 85°C and 2.5 bar. Secondary side, space heating 60°C and 2.5 bar. Secondary side DHW 60°C and 4.0 bar.
Range of copper brazed, stainless steel heat exchangers in various sizes (4-300 plates, see model). Models size X8T-SC-S Maximum working pressure primary circuit: 32.0 bar Maximum working pressure secondary circuit: 26.0 bar Maximum operating temperature: 99°C Models size 10T-SC-M Maximum working pressure primary circuit: 41.0 bar Maximum working pressure secondary circuit: 36.0 bar Maximum operating temperature: 99°C Models size 15T-SC-M Maximum working pressure primary circuit: 45.0 bar Maximum working pressure secondary circuit: 45 bar Maximum operating temperature: 99°C Models size 16DW-SC-S Maximum working pressure primary circuit: 16.0 bar Maximum working pressure secondary circuit: 16.0 bar Maximum operating temperature: 99°C Models size 16DW-SC-M Maximum working pressure primary circuit: 45.0 bar Maximum working pressure secondary circuit: 45.0 bar Maximum operating temperature: 99°C Models size 220-SC-S Maximum working pressure primary circuit: 25.0 bar Maximum working pressure secondary circuit: 25.0 bars Maximum operating temperature: 99°C Models size 320HT-SC-S Maximum working pressure primary circuit: 33.0 bar Maximum working pressure secondary circuit: 29.0 bar Maximum operating temperature: 99°C Models size 320LT-SC-S Maximum working pressure primary circuit: 33.0 bars Maximum working pressure secondary circuit: 29.0 bars Maximum operating temperature: 99°C
Range of wall mounted combination boilers providing domestic hot water via a plate heat exchanger and pressurised central heating system. Incorporating a pressure relief valve and expansion vessel. Primary circuit has a maximum working pressure of 3.5 bar and operating temperature of 85°C. Secondary circuit has a maximum working pressure of 10.0 bar and operating temperature of 60°C.
Air break to drain, incorporating brass bodies with a grey epoxy powder coating. Maximum operating temperature 60°C.
Wall mounted chrome plated brass elbow fitting. Maximum working pressure 5.0 bar. Maximum operating temperature 70°C.
Hygienic flush box providing a timed flush facility. The supply is via a single check valve cartridge however, the complete product has not been fully tested to demonstrate it provides backflow protection, flow sensor, spherical ball valve and strainer. The products incorporate a type `AB` airgap (verified by test - suitable for backflow protection against fluid category 5). The units have multiple interface user functions for timed flush, wireless technology and data storage. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.
Maincor Manifold having a brushed chrome plated body with 2 ,3 or 4 ports each with an isolation valve with red or blue indicators for hot and cold feeds. Supplied with a blanking plug and nut. Maximum working pressure 6.0 bar. Maximum operating temperature 75°C.
Range of flow measurement devices (DZR brass) bodies incorporating two test ports. Maximum working pressure 25.0 bar. Maximum operating temperature 85°C.
Range of interlocked EPDM lined shower hoses assemblies with EPDM gaskets. Maximum operating temperature is 85°C. bar.
Range of shower handsets incorporating ABS bodies (chrome plated), EPDM seals and ‘O’-rings. Maximum operating temperature 65°C.
Wall mounted vandal resistant shower head with (chrome plated brass finish). The inlet incorporates an approved check valve cartridge however, the complete product has not been fully tested to demonstrate it provides backflow protection. The outlet incorporates a plastic aerator. Open outlet use only. Maximum operating temperature 60°C.
A range of shower handsets with chromium plated plastic bodies and a plastic strainer and flow regulator in the inlet. Models may incorporate dark grey alternative shower plate. Maximum operating temperature 85°C.
Overhead, ceiling mounted shower outlet with chromium plated brass body (various finishes). Maximum operating temperature 60°C.
Shower handset incorporating a plastic body (chrome plated), brass wall connector (chrome plated) and shower hose. The inlet to the shower and wall connector incorporates approved check valve cartridges, however, the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum operating temperature 60°C.
Range of over head shower outlets incorporating brass bodies and an adjustable ball joint. The inlet incorporates a combined NBR washer and stainless-steel filter. Maximum operating temperature 60°C.
Range of wall mounted shower kit with brass bodies (various finishes) consisting of a shower rail with an overhead shower rose, incorporating a manual diverter to shower handset. Shower handset incorporates an approved check valve cartridge, however, the complete product has not been fully tested to demonstrate it provides backflow protection. Models AOOSCPUK and AOOSBKUK consist of just a shower handset. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.
Range of shower outlets with brass bodies (various finishes) and NBR ‘O’ rings. The inlets incorporate a flow regulator. Maximum operating temperature 60°C. Open outlet use only.
Range of wall mounted shower outlets (chromium plated brass). Models ARMW02 and ARMW05 are supplied with metal backnuts. Maximum operating pressure 10.0 bar. Maximum operating temperature 65°C.
Range of in-line `Y`-patterned strainers with either brass or DZR brass bodies (see model) incorporating a stainless steel mesh strainer and a PTFE washer. Maximum working pressure 25.0 Bar. Maximum operating temperature 99.0°C
Range of Y-patterned strainers incorporating ductile iron, blue epoxy coated bodies and stainless steel screen. Maximum working pressure 16.0 bar. Maximum operating temperature 85°C
Range of Y-patterned strainers incorporating ductile iron, blue epoxy coated bodies and stainless steel screen. Maximum working pressure 16.0 bar. Maximum operating temperature 85°C
Drain off valve with brass body (chrome plated) and NBR ‘O’-rings. Maximum working pressure 16.0 bar. Maximum operating temperature 99°C.
Range of drain off taps incorporating DZR brass bodies, non-rising spindle operating mechanism and EPDM ‘O’-rings and seat washer. D340 range incorporates a lockshield mechanism and the D341 range incorporates a key operated mechanism. Maximum working pressure 16.0 bar. Maximum operating temperature 85°C.
Pillar tap with brass body (various finishes), incorporating a quarter turn ceramic disc headwork and cross top operating member. The spout outlet incorporates an aerator. Maximum working pressure 10.0 bar. Maximum operating temperature is 60°C.
Basin pillar taps (chrome plated brass) with quarter turn ceramic disc headwork and single lever or cross top operating members. The spout outlets incorporate a plastic flow straightener. The product is supplied with plastic backnuts. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.
Range of wall mounted taps (chromium plated brass) incorporating non-rising spindle headworks with cross top operating members. Maximum working pressure 10.0 bar. Maximum operating temperature 65°C.
Range of pillar taps (chromium plated brass) incorporating non rising spindle headworks and cross top operating members. The spout outlets incorporate a plastic flow straightener. The products are supplied with metal backnuts. Maximum working pressure 10.0 bar. Maximum operating temperature 65°C.
Range of pillar taps (chromium plated brass) incorporating non rising spindle headworks and cross top operating members. The spout outlets incorporate a plastic flow straightener. The products are supplied with metal backnuts. Maximum working pressure 10.0 bar. Maximum operating temperature 65°C.
Range of wall or floor mounted, self-closing taps (chromium plated brass) with spring loaded headworks and either dome type, foot pedal or stick operating members. The outlet of model 9003S incorporates a plastic flow straightener. Maximum working pressure 5.0 bar. Maximum operating temperature 60⁰C.
‘TAQ PEX’ range of PEX lined flexible hose assemblies with either stainless steel braiding or grey polymeric (PET - Polyethylene terephthalate) braiding (ACB suffix models). Models have either EPDM ‘O’-rings and/or EPDM or silicone washers (depending on end connection). Models are also available with an optional washer incorporating a stainless steel strainer. Maximum working pressure 10.0 bar. Maximum operating temperature 85°C.
Range of concealed flow controls (brass body with various different finishes) incorporating two, quarter turn ceramic disc headworks with single lever operating members controlling the flow to an external outlet (not supplied). Model BK2 is a flow control with adjustable bracket and collection box. Model BK2A is a flow control with bracket. Model BK2B is a flow control. Maximum working pressure 10.0 bar. Maximum operating temperature 70°C
Range of manually operated, wall mounted, concealed blending valves (chromium plated brass), incorporating a ceramic cartridge headwork, controlling both flow and temperature, with a single lever operating member. All models incorporate integrated shower connections and hoses. Model 36111970 is supplied with a mounting bracket. The inlets of all models incorporate an approved check valve cartridge however, the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.
Range of wall mounted concealed thermostatic shower valves (brass bodies), incorporating a ceramic disc controlling the flow. The temperature is controlled independently via a thermostatic cartridge, using dome type operating members incorporating a manual override button. The inlets incorporate an approved single check valve cartridge however, the complete assembly has not been fully tested to demonstrate that it provides adequate backflow protection. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C
Range of wall mounted thermostatic shower valves with brass bodies (chromium plated) incorporating a ceramic disc controlling the flow to the overhead shower using a dome type operating member. The temperature is controlled independently via a thermostatic cartridge with a dome type operating member incorporating a manual override button. Inlets incorporate stainless steel strainers and approved single check valve cartridges however, the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C
Shower kit consisting of a wall mounted thermostatic blending valve with a brass body (chrome plated), incorporating quarter turn ceramic disc headwork which controls the flow with dome operating members, temperature is controlled independently via a thermostatic cartridge with dome type operating member which incorporate a manual override button.. Each inlet incorporates an approved check valve cartridge, however, the complete product has not been fully tested to demonstrate it provides backflow protection. The product is supplied with shower hose, shower handset, riser rail. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.
Wall mounted (vertical) thermostatic blending valve (chromium plated brass) incorporating a non-rising spindle headwork controlling the flow with a dome type operating member. The temperature is controlled independently via a thermostatic cartridge with a dome type operating member that also incorporates a manual override button. The inlets incorporate stainless steel strainers and an approved check valve cartridge however, the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum working pressure 10.0 bar. Maximum operating temperature 65°C.
Range of two hole wall mounted thermostatic bar type mixing valves with a chrome plated brass body, incorporating a quarter turn ceramic disc headwork with dome type operating member. The temperature is controlled independently via a thermostatic cartridge with dome type operating member that incorporates a manual override button. Inlets incorporate stainless steel strainers and approved check valve cartridges however, the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum working pressure 8.0 bar. Maximum operating temperature 60°C.
Range of wall mounted thermostatic blending valves with chrome plated brass bodies and ceramic disc headwork with a dome type operating member. Temperature is controlled independently via a thermostatis cartridge also with a dome type operating member. Inlets incorporate single check valve cartridges however, the complete assembly has not been tested to demonstrate it provides adequate backflow protection. Supplied with a shower, hose, handset and rail. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.
Shower kit consisting of a wall mounted thermostatic blending valve incorporating a brass body (chrome plated), quarter turn ceramic disc headwork controlling the flow, the temperature is controlled via a thermostatic cartridge which incorporates a manual override button and dome type operating members. Each inlet incorporates a combined EPDM washer with stainless steel strainer and an approved check valve cartridge, however, the complete product has not been fully tested to demonstrate it provides backflow protection. The product is supplied with shower hose, shower handset, riser rail. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.
Range of wall mounted bar type thermostatic shower mixers (chromium plated brass) incorporating a ceramic disc headworks controlling the flow, temperature is controlled via a thermostatic cartridge with dome type or cube type (model WCTS). All operating members incorporate a manual override button. Inlets incorporate approved single check valve cartridges (however, the complete assemblies have not been fully tested to demonstrate that they provide adequate backflow protection) and stainless steel strainers. All products are supplied with a shower hose, shower handset, riser rail & soap tray. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.
Thermostatic blending valve with brass body (various finishes), incorporating two push cartridges to control the water to the 2 outlets independently. The temperature is controlled also controlled independently via a thermostatic cartridge with a dome operating member incorporating a manual override button. Both inlets incorporate an approved check valve cartridge, however, the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.
Range of concealed thermostatic shower blending valves (brass) incorporating quarter turn ceramic disc headworks controlling the flow with single lever/cross/dome operating members. Model 3551197090 has one headwork controlling the flow to a single outlet. Models 355249790 & 3552197090 have two headworks independently controlling the flow to two outlets. Model 3553497090 has three headworks independently controlling the flow to three outlets. The temperature is controlled independently via a thermostatic cartridge with a single lever operating member. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.
T-type thermostatic mixing valve with brass body, EPDM ‘O’-rings and stainless-steel strainers. The inlets incorporate stainless-steel strainers and an approved check valve cartridge verified by test (as suitable for backflow protection against Fluid Category 2). Maximum working pressure 10.0 bar. Maximum operating temperature 60°C
Range of handwheel & gear operated butterfly valves with blue epoxy coated ductile iron bodies and discs and EPDM rubber seat. Maximum working pressure 16.0 bar. Cold water use only. Maximum operating temperature 85°C (from Sept 2021)
Range of combined pre-set temperature and pressure relief valves incorporating Bronze bodies, DZR brass seat and plunger, EPDM ‘O’-rings, PTFE seal and silicone diaphragm. The valves incorporate a manually operated lever easing gear. The valves are factory pre-set between 0.4 bar and 12.5 bar. Maximum operating temperature 90°C.
Range of single hole, single outlet, manually operated flow control valve (brass bodies) incorporating a quarter turn ceramic disc headwork housed and supplied with either single lever, dome type or cross top (see model) operating members. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C
Range of flow control valves incorporating quarter turn ceramic disc headworks housed within a brass bodies. Maximum working pressure 6.0 bar. Maximum operating temperature 60°C
Range of adjustable in-line pressure reducing valves with bronze bodies and manually operated pressure reducing mechanism. Outlet pressure adjustable between 1.5 to 6.0 bar. Maximum supply pressure 16.0 bar. Maximum operating temperature 60°C.
Range of adjustable, in-line pressure reducing valves incorporating gunmetal bodies and EPDM diaphragm & ‘O’-rings. Maximum inlet supply pressure 16.0 bar. Maximum outlet pressure 1.5 to 5.5 bar. Cold water use only.
Range of latching solenoid valves with brass bodies, incorporating stainless steel strainer with EPDM O rings and diaphragms Maximum working pressure 12.0 Bar or 16.0 Bar on (SCPH262C020 & SCPXH262C020BW TPL 21896 Only). Maximum operating temperature 85.0°C
Spherical valves incorporating bronze bodies with lever operating members, chromium plated brass ball and PTFE seat. Maximum working pressure 25.0 bar, Maximum operating temperature 85°C.
Range of electrically actuated ball valves incorporatingstainless steel bodies and ball with PTFE seat. Various closure options are available depending on model. Maximum working pressure 10.0 bar. Maximum operating temperature 100°C.
Range of lever operated spherical valves incorporating brass bodies and brass ball (various finishes) to be used with PEX pipe (manufactured to BS7291 part 3), Polybutylene Pipe (manufactured to BS7291 Part 2) and copper pipe (manufactured to EN1057). Maximum working pressure 6.0 bar (for PEX and Polybutylene pipe). Maximum working pressure of 20.0 bar (for copper pipe). Maximum operating temperature 95˚C.
Range of gate valves with DZR brass bodies and brass wedge. Valves are operated via a non-rising spindle headwork. Maximum operating pressure 20.0 Bar. Maximum operating temperature 100°C.
Range of gate valves with blue epoxy coated ductile iron bodies, EPDM coated ductile iron wedges. The valves operate via a non-rising spindle headwork with hand wheel operating member. Maximum working pressure 16.0 bar. Maximum operating temperature 85°C.
Range of gate valves (gunmetal) with gunmetal bronze wedges, brass spindle and PTFE seals. Maximum working pressure 20.0 bar. Maximum operating temperature 100°C.
Range of gate valves incorporating bronze bodies and wedges with PTFE seals. The valves are operated via a non-rising spindle with a hand wheel operating member. Maximum working pressure 20.0 bar. Maximum operating temperature 85°C.
Range of gate valves with blue epoxy coated ductile iron bodies, EPDM coated ductile iron wedges. The valves operate via a non-rising spindle headwork with hand wheel operating member. Maximum working pressure 16.0 bar. Maximum operating temperature 85°C.
Range of screw down stop valves with brass bodies and PTFE seals. For use with copper pipe to EN1057. Maximum working pressure 16.0 bar. Maximum operating temperature 65ºC.
Range of under-counter or counter-top drinking water dispensers delivering still ambient, still chilled & sparkling water. HygienePlus®. Models incorporate a built-in filter system. The flow is controlled by a solenoid valve which is either operated by a touch or a touch pad. The water is dispensed via a tap arrangement on under-counter versions or an integrated outlet on counter-top versions. The inlets incorporate an approved check valve cartridge assembly however, the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum working pressure 6.0 bar. Cold water use only.
'Polyplumb' (grey coloured) & 'Polyfit' (white coloured) fittings. Injection moulded acetal fittings. For use with water up to 65°C.
'Birla SRPC - Electrocement'. Factory applied, grey coloured, cement mortar. Mix cement, sand & water in a mass ratio of 0.6:1.0:0.22. Cure for 24 hours@27°C. For use with water up to 60°C. This material is only approved for the mixing & curing conditions that appear on the approval. If the mix and/or cure conditions are varied from those specified on the approval then the material is not covered by the scope of the approval.
'Electrocement CEM1-SR3 - Dalmia SRPC'. Factory applied, grey coloured sulphate resisting Portland cement mortar. Mix cement, sand and water in a mass ratio of 0.6:1.0:0.22. Cure for 4 days at 26°C, and then at 32°C for a further 24 days OR 24 hours@27°C. For use with water up to 60°C. This material is only approved for the curing conditions that appear on the approval. If the cure conditions are varied from those specified on the approval then the material is not covered by the scope of the approval.
'Kubotaseal BM'. Factory applied, black coloured asphaltic bituminous coating. Apply as per manufacturer's PDS reference `11004T-1.4' dated Feb, 20, 2020. Cure 6 hours@20°C. For use with water up to 60°C. Materials listed in this section are not approved for use for contact with water that is required to be wholesome on large water retaining structures such as lining of pipes, cisterns or water storage tanks. This material is only approved for the curing conditions that appear on the approval. If the cure conditions are varied from those specified on the approval then the material is not covered by the scope of the approval.
'XX-CM1'. Factory applied, grey coloured cement mortar. Mix and apply as per manufacturer's safety data sheet 'A1: 26-01-2020'. Cure for 5 hours@30°C and then steam cure for 6 hours@30°C. For use with water up to 65°C. This material is only approved for the curing conditions that appear on the approval. If the cure conditions are varied from those specified then the material is not covered by the scope of the approval.
'XX-CM2'. Factory applied, grey coloured cement mortar. Mix and apply as per manufacturer's safety data sheet 'A1: 26-01-2020'. Cure for 5 hours@30°C and then steam cure for 6 hours@30°C. For use with water up to 65°C. This material is only approved for the curing conditions that appear on the approval. If the cure conditions are varied from those specified then the material is not covered by the scope of the approval.
'XX-CM3'. Factory applied, grey coloured sulphate resistant cement mortar. Mix and apply as per manufacturer's safety data sheet 'A1: 26-01-2015'. Cure for 5 hours@30°C and then steam cure for 6 hours@30°C. For use with water up to 65°C. This material is only approved for the curing conditions that appear on the approval. If the cure conditions are varied from those specified then the material is not covered by the scope of the approval.
'Interline 925P Off White'. Site applied, two-component, white coloured (once mixed) epoxy coating comprising of Part A (white coloured, opaque paint) and Part B (brown coloured, translucent liquid). Mix Parts A and B in a 4.93:1 mass ratio. Cure for 7 days@30°C. For use with water up to 60°C. This material is only approved for the mixing and curing conditions that appear on the approval. If the mixing and/or curing conditions are varied from those specified on the approval then the material is not covered by the scope of the approval.
'Jotapipe IL6001 50S'. Factory applied, blue coloured, fusion bonded epoxy coating. Apply as per technical data sheet dated '10 September 2019'. Cure for 15 minutes@230°C. For use with water up to 85°C. This material is only approved for the curing conditions that appear on the approval. If the cure conditions are varied from those specified on the approval then the material is not covered by the scope of the approval.
'Interline 925P Light Grey'. Site applied applied, two-component, grey coloured (once mixed) epoxy coating comprising of Part A (grey coloured, opaque paint) and Part B (brown coloured, translucent liquid). Mix Parts A and B in a 4.93:1 mass ratio. Cure for 7 days@30°C. For use with water up to 60°C. This material is only approved for the mixing and curing conditions that appear on the approval. If the mixing and/or curing conditions are varied from those specified on the approval then the material is not covered by the scope of the approval.
'Interline 925 White with Ceilcote 680M Primer'. Site applied, white coloured (once mixed), two-component epoxy coating comprising of a two-component primer and two-component top-coat. The primer (Ceilcote 680M) comprises of Part A (uncoloured liquid) and Part B (uncoloured liquid). Mix Parts A and B in a 3:1 volume ratio. Cure for 10 days@30°C. The top-coat (Interline 925 White) comprises of Part A (white coloured, opaque paint) and Part B (white coloured, opaque paste). Mix Parts A and B in a 4.99:1 mass ratio. Cure for 7 days@30°C. For use with water up to 23°C. This material is only approved for the mixing and curing conditions that appear on the approval. If the mixing and/or curing conditions are varied from those specified on the approval then the material is not covered by the scope of the approval.
'MES Precast Tank Concrete Mix'. Factory made, grey coloured concrete & additive. Mix ingredients in the following percentages: Cement 19.10 %, Water 7.56 %, Coarse Aggregate 38.76 %, Fine Aggregate 34.46 %, Plastiment 186 0.03 % & ViscoCrete 0.12 %. Cure for 7 days@10°C. For use with water up to 23°C. This material is only approved for the mixing and curing conditions that appear on the approval. If the mixing and/or curing conditions are varied from those specified on the approval then the material is not covered by the scope of the approval.
'Novapress Ambition’ (grey coloured) and ‘Novaform 660' (light green on one side and beige on the other). Fibre/NBR gasket materials manufactured by calendaring. For use with water up to 85°C. For use only as a jointing/gasket material having been tested at a reduced surface area to volume ratio.
'Aldex C800 Na (16-50 US mesh resin), Aldex C800x10 Na (16-50 US mesh resin), Aldex C800F (Na) (30-70 US mesh resin) & Aldex C800F (K) (30-70 US mesh resin)'. Ion exchange resins which are black coloured except C800F (Na) which is brown coloured. For use with water up to 23°C.
'TP1'. Factory applied, colourless solid lubricant. Apply as per manufacturer's instructions 'LDAP-005', issue 1, dated 11/11/2016. For use with water up to 85°C.
'Ultramid S3EG6 Balance Aqua Uncoloured'. Uncoloured (appears beige), injection moulded PA6/10 material. For use with water up to 85°C.
'Grivory GV XE 10726 Black 9225'. Black coloured, injection moulded, glass reinforced polyamide material. For use with water up 23°C.
'TECHNYL ® SAFE A 219WFC V30 BK’ (black coloured) & ‘TECHNYL ® SAFE A 219WFC V30 NC’ (natural, appears off-white). Injection moulded, glass fibre reinforced polyamide 6.6 materials. For use with water up to 85°C.
'RADILON® DT RV300RKC2 106 NT to RADILON® DT RV500RKC2 106 NT and RADILON® DT RV300RKC2 306 BK to RADILON® DT RV500RKC2 306 BK'. Natural (appears off-white in colour) or black, injection moulded glass fibre filled PA6.12 materials. For use with water up to 85°C.
‘TECHNYL ® SAFE D 219WFC V30 BK’ & ‘TECHNYL ® SAFE D 219WFC V50 BK’. Black coloured, injection moulded, glass fibre reinforced polyamide 6.10 materials. For use with water up to 85°C.
'Grilon BG-35/2 natural & Grilon BG-35/2 black 9697'. Natural (appears white coloured, opaque) and black coloured, injection moulded PA6-GF35 materials. For use with water up to 85°C.
'Revolve M-2638 Black'. Black coloured, polyethylene material manufactured by rotational moulding. For use with water up to 85°C.
'Revolve 4068/N-250 (white coloured), M-586 (black coloured), M-638 (black coloured), M-694 (black coloured) & M-695 (black coloured)'. Polyethylene materials manufactured using rotational moulding. For use with water up to 85°C.
'SAB A16 Compression Fittings'. Black coloured, compression fitting bodies, injection moulded from polypropylene (PP-B). For use with water up to 60°C.
'Supreme S16 Compression Fittings'. Black coloured, compression fitting bodies, injection moulded from polypropylene (PP-B). For use with water up to 60°C.
'EP1/1/5 BLK EPDM Diaphragm'. Black coloured, compression moulded EPDM diaphragm. Shore hardness 70. Tested in-radius size 0.65mm. For use with water up to 85°C.
'DLYY E6202'. Black coloured, compression moulded EPDM material. Shore hardness 60. Tested in-radius size 1.0mm. For use with water up to 23°C.
'WN60/1 BLK 'O' rings'. Black coloured, injection moulded NBR 'O' rings. Shore hardness 60. Tested in-radius size 1.31mm. For use with water up to 60°C.
`WN 22/1/9 BLK` 'O' rings. Black coloured, injection moulded, nitrile rubber 'O' rings. Shore hardness 70. Tested in-radius size 0.89mm. For use with water up to 65°C.
'SIL60 RED 'O' rings and seals'. Red coloured, injection moulded silicone rubber 'O' rings and seals. Shore hardness 60. The 'O' rings have a tested in-radius size of 1.77mm. The seals have a tested in-radius size of 0.90mm. For use with water up to 85°C.
'Griffon WDF-05'. Site applied, blue coloured solvent cement. Apply as per manufacturer's instructions '6311380 20200708'. Cure for 30 minutes@12°C. For use with water up to 23°C. This material is only approved for the curing conditions that appear on the approval. If the cure conditions are varied from those specified on the approval then the material is not covered by the scope of the approval.
'Hytrel® 6359FG & 4068FG'. Cream coloured, injection moulded, thermoplastic polyester elastomeric materials. For use with water up to 85°C.
`Aqua Clean Mera` range of bidets incorporating an electronically operated seat, flow is controlled by solenoid valve and discharges via a type `AB` airgap (verified by test - suitable for backflow protection against fluid category 5). Maximum working pressure 10.0 bar. Cold water supply only.
'EcoFITTOM Fittings'. Blue coloured PVC fittings which are manufactured by extrusion and molecular orientation. For use with water up to 60°C.
'TOM PVC-O Pipe'. Blue coloured PVC pipe which is manufactured by extrusion and molecular orientation. For use with water up to 60°C.
Range of single hole, single outlet (fixed) electronically controlled tap assemblies (either stainless steel or brass bodies in a variety of finishes). Flow is controlled via two solenoid valves (housed in a control box) activated via an infra-red sensor, the inlets to the control box incorporate stainless steel strainers. The temperature is controlled independently via a ceramic cartridge with a dome type operating member. The spout outlet incorporates a plastic aerator. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.
Range of side entry BS1212-4 (2016) delayed action or non-delayed action type float operated valves for WC flushing cisterns. The inlet incorporates an optional flow restrictor. Maximum working pressure 10.0 bar. Cold water use only.
BS EN 14055: 2018 concealed WC cistern incorporating a side or bottom entry compact type float operated inlet valve providing a Type AG air gap with a pneumatic or cable operated drop valve capable of full flush volumes of up to 6 litres and reduced flush of up to 4 litres. The cistern is operated by a manual push button. Maximum working pressure 10.0 bar. Cold water use only.
BS EN 14055: 2018 concealed WC cistern incorporating a side entry compact type float operated inlet valve providing a type `AB` airgap (verified by test - suitable for backflow protection against fluid category 5) with a pneumatic or cable operated drop valve capable of full flush volumes of up to 6 litres and reduced flush of up to 4 litres. The cistern is operated by manual push button. Maximum working pressure 10.0 bar. Cold water use only.
Range of deck mounted, three-hole, single outlet (fixed) combination tap assemblies (chromium plated brass), incorporating a ceramic cartridge headwork and manually operated diverter valve, both models RAKSOR3013C and RAKPOR3013C use single lever operating members and model RAKAMA3013C has a dome type operating member. The spouts incorporate a plastic aerator. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.
Spring loaded, resilient trim, in-line check valve cartridge with plastic guide, stem, body and EPDM O-rings. Maximum working pressure 16.0 bar. Maximum operating temperature 85°C.
Spring loaded resilient trim in-line check valve cartridge with plastic guide, stem and housing, stainless steel spring and EPDM ‘O’-rings. For insertion into specifically dimensioned bores. Maximum working pressure 16.0 bar. Maximum operating temperature 85°C.
Range of spring loaded, resilient trim, in-line check valve cartridgse, with plastic guides & jumper and NBR or EPDM seals within a plastic housing. For insertion in pipes and fittings with specifically sized bores. Maximum working pressure 16.0 bar. Models NV20/DN20-EPDM 31.0004.0 & NV20/DN20-pr 31.0071.0 have a maximum operating temperature of 60°C. Models NV20/DN20 31.4221.0 & NV20/DN20-HT 31.0011.0 have a maximum operating temperature of 85°C.
Range of spring loaded, resilient trim, in-line check valve cartridge, with plastic guides & jumper and NBR or EPDM seals within a plastic housing. For insertion in pipes and fittings with specifically sized bores. Maximum working pressure 16.0 bar. Model 31.4220.0. has a maximum operating temperature of 85°C. Model 31.0003.0 has a maximum operating temperature of 60°C.
Range of spring loaded, resilient trim, in-line check valve cartridges, with plastic guides & plunger and EPDM or Silicone seals within a plastic housing. For insertion in pipes and fittings with specifically sized bores. Maximum working pressure 16.0 bar. Maximum operating temperature 60°C
Range of spring loaded, resilient trim, in-line check valve cartridges with plastic guide, stem and body with NBR or EPDM 'O'-rings. Maximum working pressure 16.0 bar. Maximum operating temperature 60°C for model NV15/DN15-EPDM 31.0002.0. All other models have a maximum operating temperature of 85°C.
Range of non-verifiable double check valve assemblies consisting of two spring loaded resilient trim in-line check valve cartridges housed in a DZR brass body, compression models are nickle plated. A drain port is provided between the cartridges. Compression models are to be used with copper pipe to EN1057. Maximum working pressure 16.0 Bar. Maximum operating temperature for the D220W range 85°C. Maximum operating temperature of the D200CW range 60°C.
‘Parker 500’ assisted bathing unit. Flow is controlled via a thermostatic mixing valve, the inlet of which incorporates a stainless steel strainer and single check valve cartridge (suitable for backflow protection against Fluid Category 2) and feeds either a bath spout outlet or shower handset which incorporates a self-closing trigger. The inlet to the shower handset incorporates a plastic flow restrictor and a single check valve cartridge however, the complete product has not been fully tested to demonstrate it provides backflow protection. There is a combined spherical valve and strainer on the inlet to the bathing unit which incorporates a single check valve cartridge (suitable for backflow protection against Fluid Category 2). The ‘shepherds crook’ type shower outlet is protected via an AUK3 airgap arrangement. Maximum working pressure 6.0 bar. Maximum operating temperature 80°C
One-piece (white) HDPE plastic storage cistern with lid. Maximum operating temperature 60°C.
An aerator attachment for a mixer tap with a black plastic body and NBR O-rings. The outlet incorporates a stainless-steel strainer. This product incorporates swivel joint and a mechanism that alters the flow from jet to spray. Maximum working temperature 60°C.
Range of ceramic cartridge headworks with plastic bodies incorporating silicone seals for insertion into specifically dimensioned bodies. Maximum working pressure 10.0 bar. Maximum operating temperature 65°C
Ceramic cartridge headwork with plastic body and silicone seals, for insertion into specifically dimensioned tap assemblies. Maximum working pressure 10.0 bar. Maximum operating temperature 85°C.
Range of quarter turn and half turn ceramic disc headworks with brass bodies and silicone rubber gaskets for insertion into specifically dimensioned assemblies. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.
Range of non-rising spindle headworks incorporating brass bodies, NBR rubber `O`-rings and silicone rubber gaskets. Model CL1/2M-360T 360° incorporates a non -rising spindle headwork, model CL1/2K-180T-10 incorporate a half turn ceramic disc headwork and other models incorporate a quarter turn ceramic disc headwork. Maximum working pressure 10.0 bar. Maximum operating temperature 85°C.
Range of non-rising headworks incorporating brass bodies, NBR ‘O’-rings and EPDM gaskets. The products are intended for insertion into specifically dimensioned tap assemblies. Maximum working pressure 16.0 bar. Maximum operating temperature 85°C.
Single hole, single outlet (fixed) combination tap assemblies (chromium plated brass), incorporating a quarter turn ceramic disc headworks and single lever operating members, with a pull out spray retained within a holster. The spout outlet incorporates a plastic aerator. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.
Range of single hole, single outlet (fixed) combination tap assemblies (chromium plated brass). incorporating a ceramic cartridge and single lever operating member with a spring loaded, pull down trigger operated spray. The spout outlet incorporates a plastic aerator. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.
Single hole, single outlet fixed combination tap assembly (chromium plated brass), incorporating a ceramic cartridge headwork with a single lever operating member. The spout outlet incorporates a plastic flow straightener and the product is supplied with a click type waste. Maximum operating pressure 5.0 bar. Maximum operating temperature 60°C
Range of single hole, single outlet (fixed) combination tap assemblies (chromium plated brass) incorporating a ceramic cartridge headwork with a single lever operating member. The spout outlet of model 825JK incorporates a plastic aerator. Products are supplied with a click type waste. Maximum operating pressure 5.0 bar. Maximum operating temperature 60°C
Range of single hole, single outlet (fixed) combination tap assemblies with brass bodies (various finishes) incorporating a ceramic cartridge headwork with single lever operating members. The spout outlets incorporate a plastic aerator. Product is supplied with a pop-up waste. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.
Single hole, single outlet (waterfall spout) combination tap assembly with brass body (various finishes), incorporating a ceramic cartridge headwork with single lever operating member. The inlets incorporate a stainless-steel strainer and the product is supplied with a pop-up waste. Maximum working pressure 10.0 bar. Maximum operating temperature 60ºC.
Range of single hole, single outlet (fixed) combination tap assemblies (chromium plated brass), incorporating ceramic cartridge headworks with single lever operating members. The spout outlets incorporate a plastic aerator. Products come with pop up wastes. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.
Range of single hole, single outlet (fixed) combination tap assemblies with brass bodies (various finishes), incorporating a ceramic cartridge headworks and single lever operating member. The spout outlets incorporate a plastic aerator. Some models are supplied with a pop-up waste. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.
Range of single hole, single outlet (fixed) combination tap assemblies (chromium plated brass) incorporating a ceramic cartridge headwork with a single lever operating member. The spout outlets incorporate either a plastic flow straightener or aerator. The product is supplied with a click type waste. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.
Range of single hole, single outlet (fixed) combination tap assemblies (chromium plated brass), incorporating a ceramic cartridge headwork with a single lever operating member. The spout outlet incorporates a plastic flow straightener with an optional aerator. Fittings are supplied with a pop-up waste. Maximum working pressure 5.0 Bar. Maximum operating temperature 60°C.
Range of single hole, single outlet (fixed) combination tap assemblies (chromium plated brass), incorporating a ceramic cartridge headwork with a single lever operating member. The spout outlet incorporates a plastic flow straightener with an optional aerator. Fittings are supplied with a pop-up waste. Maximum working pressure 5.0 Bar. Maximum operating temperature 60°C.
Range of single hole, single outlet (fixed) combination tap assemblies (chromium plated brass), incorporating ceramic cartridge headworks and single lever operating members. The tap body incorporates plastic flow regulator and the product is also supplied with a click type pop-up waste. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.
Range of single hole, single outlet (fixed) combination tap assemblies (chromium plated brass), incorporating ceramic cartridge headworks, single lever operating members. The spout outlets incorporate a plastic aerator and the products are supplied with a pop up waste. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.
Range of single hole, single outlet (fixed) combination tap assemblies (chromium plated brass). Incorporating ceramic cartridge headworks, and single lever operating members. The spout outlets incorporate a plastic aerator and some models are supplied with a pop-up waste. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.
Single hole, single outlet (swivel) combination tap assembly (chromium plated stainless steel) incorporating quarter turn ceramic disc headworks and single lever operating members. The spout outlet incorporates a plastic aerator. Maximum working pressure 8.0 bar. Maximum operating temperature 60°C.
Range of single hole, single outlet (swivel) combination tap assemblies with brass bodies (various finishes), incorporating ceramic cartridge headworks and single lever operating members. The spout outlets incorporate a plastic aerator. Maximum working pressure 8.0 bar. Maximum operating temperature 60°C.
Range of single hole, single outlet (swivel) combination tap assemblies (chromium plated brass), incorporating ceramic cartridge headworks and single lever operating members. The spout outlet incorporates a plastic aerator. The inlets incorporate an approved check valve cartridge, however, the complete product has not been fully tested to demonstrate it provides backflow protection Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.
Single hole, single outlet (swivel) comination tap assembly (chromium plated brass), incorporation a ceramic disc headwork with lever type operating members.The spout outlets incorporate a metal strainer and either a plastic aerator or alternative flow straightener. Maximum working pressure 10.0 bar. Maximum operating temperature 70°C
Range of single hole, single outlet (swivel) combination tap assemblies (chromium plated brass), incorporating a ceramic cartridge headwork with a single lever operating member. The spout incorporates a plastic aerator, model BM1400 Blanco Crest incorporates a plastic flow straightener. Maximum operating pressure 5.0 bar. Maximum operating temperature 60˚C.
Range of single-hole, single outlet, (swivel) combination tap assemblies with brass bodies (various finishes), incorporating quarter turn ceramic cartridge headworks with single lever operating members. The spout outlets incorporate a plastic aerator and the inlets incorporate a stainless-steel strainer. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.
A range of single-hole, single outlet, (swivel) combination tap assemblies with brass bodies (chromium plated). Incorporating ceramic cartridge headworks with single lever operating members. The spout outlets incorporate a plastic aerator. Maximum working pressure 5.0 bar, Maximum working temperature 60 °C.
Range of single hole, single outlet, (swivel) combination tap assemblies with brass bodies (chromium plated), incorporating ceramic cartridge headworks and single lever operating members. The spout outlet incorporates a plastic aerator. The inlet hoses incorporate a combined stainless-steel strainer and silicone washer. Maximum working pressure 5.0 bar. Maximum working temperature 60°C.
Range of single hole, single outlet (swivel) combination tap assemblies with brass bodies (various finishes). Models SM056, SM056F, SM056/501, SM056/NI & SM056/BZ incorporate ceramic cartridge headworks with single lever operating members. Models SM057 & SM057/501 incorporate non-rising spindle headworks with cross top operating members. The spout outlet incorporates a plastic flow straightener. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.
Range of single hole, double outlet (swivel) combination tap assemblies (chromium plated brass). All models can be specified with either a non rising spindle headwork or a quarter turn ceramic disc headwork with dome (Tevere), cross top (Monaco) or single lever (Miura) operating members. The spout outlet incorporates a plastic flow straightener. Maximum working pressure 10.0 bar. Maximum operating temperature 65°C.
Range of wall mounted, two-hole, single outlet (fixed) combination tap assemblies with brass bodies (various finishes), incorporating ceramic cartridge headworks, and single lever operating members. The spout outlet incorporates a plastic aerator. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.
Range of wall mounted, concealed two-hole, single outlet (fixed) combination tap assemblies (brass bodies, various finishes) incorporating ceramic cartridge headwork with single lever operating members. The spout outlets incorporate a plastic aerator, some also incorporate a flow regulator. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C
Range two hole, single outlet (fixed) combination tap assembly (chromium plated brass), incorporating quarter turn ceramic disk headworks with single lever or cross top (model MOT108) operating members. The spout outlets incorporates a plastic flow straightener. The products are supplied with plastic backnuts. Maximum working pressure 6.0 bar. Maximum operating temperature 60°C.
Two-hole, singe outlet (fixed) combination tap assembly (chromium plated brass). Incorporating a quarter turn ceramic disc headworks with single lever type operating members. The outlet incorporates a plastic flow straightener. Product is also supplied with plastic back nuts. Maximum working pressure 10.0 bar. Maximum operating temperature 60ºC.
Range of deck mounted, two hole, single outlet (fixed) combination tap assemblies (various finishes), incorporating a non-rising spindle headwork with cross top operating members and a manual diverter to shower outlet. The product is supplied with a shower hose and handset. Maximum working pressure 10.0 bar. Maximum operating temperature 65°C.
Two-hole, single outlet (fixed) combination tap assembly with brass body (chromium plated). The flow is controlled via a quater turn ceramic disc headworks and single lever operating members and a manually operated diverter to shower outlet. Supplied with metal backnuts. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.
Two-hole, single outlet (fixed) combination tap assembly (chromium plated brass). The flow is controlled via non-rising spindle headworks with cross top operating members and a manually operated diverter to shower outlet. Supplied with hose and handset. The spout outlet incorporates a plastic flow straightener. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.
Two-hole, single outlet (fixed) combination tap assembly (chromium plated brass). The flow is controlled via non-rising spindle headworks with cross top operating members and a manually operated diverter to shower outlet. Supplied with hose and handset. The spout outlet incorporates a plastic flow straightener. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.
Two-hole, single outlet (fixed) combination tap assembly (chromium plated brass), incorporating quarter turn ceramic disc headwork with single lever operating members and a self-cancelling diverter to shower outlet. The spout outlet incorporates a plastic flow straightener. The product is supplied with a shower hose, shower handset and metal backnuts. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.
Two-hole, single outlet (fixed) combination tap assembly (chromium plated brass), incorporating quarter turn ceramic disc headwork with single lever operating members and a self-cancelling diverter to shower outlet. The spout outlet incorporates a plastic flow straightener and the product is supplied with a shower hose, shower handset and metal backnuts Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.
Two hole, single outlet (fixed) combination tap assembly (chromium plated brass), incorporating ceramic disc headworks with single lever operating members and a self-cancelling diverter to the shower outlet. The spout outlet incorporates a plastic flow straightener or optional aerator. The product is supplied with a shower hose, shower handset and metal backnuts. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.
Deck mounted, two-hole, single outlet (fixed) combination tap assembly (chromium plated brass) incorporating quarter turn ceramic disc headworks with single lever operating members and a self-cancelling diverter to the shower outlet. The spout outlet incorporates a plastic flow straightener or an optional aerator. The product is supplied with a shower hose, shower handset and metal backnuts. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.
Deck mounted, two-hole, single outlet (fixed) combination tap assembly (chromium plated brass) incorporating quarter turn ceramic disc headworks with single lever operating members and a self-cancelling diverter to the shower outlet. The spout outlet incorporates a plastic flow straightener or an optional aerator. The product is supplied with a shower hose, shower handset and metal backnuts. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.
Two-hole, single outlet (fixed) combination tap assembly (chromium plated brass), incorporating quarter turn ceramic disc headwork with single lever operating members and a self-cancelling diverter to shower outlet. The spout outlet incorporates a plastic flow straightener. The product is supplied with a shower hose, shower handset and metal backnuts. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.
Two-hole, single outlet, (fixed) combination tap assembly with brass body (various finishes), incorporating a ceramic cartridge headwork with single lever operating members and a self-cancelling diverter to shower outlet. The spout outlet incorporates a plastic aerator and the shower outlet incorporates an approved check valve cartridge, however, the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.
Range of wall mounted, two-hole, single outlet (swivel) combination tap assemblies (chromium plated brass), incorporating ceramic cartridge headworks and single lever operating members. The spout outlet incorporates a plastic flow straightener. The inlet offset unions incorporate an isolation valve. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.
Range of deck mounted, two-hole, single outlet (fixed), combination tap assemblies (chromium plated brass). The flow is controlled by quarter turn ceramic disc headwork, with dome operating members, which also diverts the flow between multiple shower outlets. The temperature is controlled by a thermostatic cartridge with dome type operating members and manual override button. The products incorporate a lockable diverter to shower outlet and the spout outlets incorporate a plastic flow straightener. Both inlets incorporate stainless steel strainers and approved check valve cartridges, however, the complete products have not been fully tested to demonstrate that they provide backflow protection. Model TLVBSM is supplied with a shower hose and shower handset. Model TLVBSM2B is supplied with a shower hose, shower handset, riser rail and soap dish. Both models are supplied with metal back nuts. Maximum working pressure 5.0 Bar. Maximum operating temperature 60°C.
Range of two hole, double outlet (swivel) combination tap assemblies (chromium plated brass). All models can be specified with either a non rising spindle headwork or a quarter turn ceramic disc headwork with dome (Tevere), cross top (Monaco) or single lever (Miura) operating members. The spout outlet incorporates a plastic flow straightener. The product is supplied with metal backnuts. Maximum working pressure 10.0 bar. Maximum operating temperature 65°C.
Range of three hole, deck mounted, single outlet (fixed) combination tap assemblies (various finishes, see model) incorporating quarter turn ceramic disc headwork with either cross top or single lever operating members and interconnecting flexible hoses. The spout outlets incorporate a plastic aerator. Products are supplied with a pop-up waste. Maximum working pressure 4.1 bar. Maximum operating temperature 60°C.
Range of wall mounted three hole, single outlet (fixed) combination tap assemblies with brass bodies (various finishes) incorporating quarter turn ceramic disc headworks and single lever operating members. The spout outlets incorporate a plastic aerator. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.
Range of three hole, single outlet (fixed) combination tap assemblies with brass bodies (various finishes). Incorporating quarter turn ceramic disc headworks and single lever operating members and interconnecting flexible hoses. The spout outlets incorporate a plastic aerator. Maximum working pressure 10.0 Bar. Maximum operating temperature 60°C.
Three hole, single outlet (fixed) combination tap assemblies (various finishes), incorporating quarter turn ceramic disc headworks with single lever operating members. The spout outlets incorporate a plastic aerator and is connected to the headworks via stainless steel braided PEX lined hose assemblies. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.
Three hole, single outlet (fixed) combination tap assemblies with a brass body (various finishes), incorporating quarter turn ceramic disc headworks with single lever operating members and a self-cancelling diverter to shower outlet. The spout outlet incorporates a plastic flow aerator. Maximum working pressure 10.0 Bar. Maximum operating temperature 60ºC.
Range of three hole, single outlet (swivel) combination tap assembly (chromium plated brass) incorporating quarter turn ceramic disc headwork with single lever operating members. The spout outlet incorporates a plastic aerator. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.
Four-hole, single outlet (fixed) combination tap assembly (chromium plated brass), incorporating a ceramic cartridge headwork with a single lever type operating member and a self-cancelling diverter to shower outlet. The spout outlet incorporates a plastic flow straightener. The product is supplied with a shower hose & handset. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.
Range of five hole, single outlet (swivel) combination tap assemblies (chromium plated brass). Incorporating a ceramic cartridge headwork controlling the flow to the shower handset and two quarter turn ceramic disc headworks controlling the flow to the spout outlet, all with single lever operating members. The spout outlets incorporate a plastic aerator. The inlet to the shower handsets incorporate an approved check valve cartridge, however, the complete product has not been fully tested to demonstrate it provides backflow protection. The product is supplied with a shower hose and handset. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.
Range of combined bath fillers and overflows with a plastic body and a variety of different trims. The outlet incorporates a plastic flow regulator and the products are supplied with a cable operated pop-up waste. Maximum operating temperature 65°C.
Range of floor mounted, single hole, single outlet fixed combination tap assemblies (chromium plated brass with a self-cancelling diverter to shower outlet. The product incorporates a ceramic cartridge headwork and single lever operating member. The spout outlets incorporate an aerator and the product is supplied with a hose and handset. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.
Wall mounted fixed spout outlet (chromium plated brass) with a plastic aerator. Maximum operating temperature 60°C
Wall mounted bath spout outlet with a brass body (chrome plated) and a plastic aerator. The spout outlet are supplied with a single lever type operating member. Maximum operating temperature 60°C.
Wall mounted bath spout outlet incorporating a brass body (chromium plated) and a plastic aerator. The product is supplied with a single lever type operating member. Maximum operating temperature 60°C.
Wall mounted spout outlet incorporating brass body (chrome plated) and NBR ‘O’-rings. Maximum working pressure 10.0 bar. Maximum operating temperature 85°C.
‘HydroDOS’ chlorine dioxide dosing system with PVC-u pipework and EPDM ‘O’-rings. The product incorporates a water meter, strainer, isolation valves and a drain cock with hose spigot. Maximum working pressure 6.0 bar. Cold water use only.
Filling loop assembly, consisting of a stainless steel braided EPDM lined flexible hose, a lever operated brass spherical valve and a DZR brass double check valve assembly that incorporates a lever operated spherical valve. Maximum working pressure 10.0 bar. Maximum operating temperature 23°C.
Range of LK press fittings with brass bodies and stainless steel sleeves for use with LK Universal PEX pipe. Jointing is achieved by hydraulic compression. Maximum working pressure 10.0 bar. Maximum operating temperature 95°C.
Range of Aquaterra PP-RCT socket fusion fittings for use with Aquaterra PP-RCT SDR 6 pipe and Aquaterra PP-RCT SDR 7.4 pipe (manufactured to EN ISO 15874). Maximum working pressure 10.0 bar. Maximum working temperature 85°C.
Viega ‘Raxofix’ press connection fittings for use with viega Raxofix PE-Xc/Al/PE-Xc pipes. For above ground use only. Maximum working pressure 10 bar. Maximum operating temperature 70°C
Viega ‘Raxofix’ press connection fittings for use with viega Raxofix PE-RT/Al/PE-RT pipes. For above ground use only. Maximum working pressure 10.0 bar. Maximum operating temperature 70°C
‘Maincor’ range of pipe adaptors and ‘Multi-Fit’ straight connectors (brass bodies) for use with ‘Maincor PERT/Al/PERT MLC’ pipe. 12mm pipe and fittings have a maximum working pressure of 6.0 bar. 16mm & 20mm pipe and fittings have a maximum working pressure of 10.0 bar Maximum operating temperature 95°C
Range of brass caplillary fittings for use with EN1057 copper tube. Maximum working pressure 10.0 bar. Maximum operating temperature 85°C.
Range of brass caplillary fittings for use with EN1057 copper tube. Maximum working pressure 10.0 bar. Maximum operating temperature 85°C.
Range of brass compression fittings for use with copper pipe to EN1057. Maximum working pressure 16.0 bar. Maximum operating temperature 100°C.
Range of copper end feed fittings for use with copper tube. For above and below ground use. Maximum working pressure 25.0 bar. Maximum operating temperature 99°C.
Range of gas fired water heaters incorporating stainless steel strainers on the inlets. Maximum working pressure 10.0 Bar Maximum working temperature 85˚C
RINNAI range of wall mounted combination boilers.The unit incorporates a stainless-steel plate heat exchanger pressure relief valve set at 3.0 bar and an expansion vessel on the primary circuit. Maximum working pressure of primary circuit is 2.5 bar and secondary circuit is 10.0 bar. Maximum operating temperature 60˚C.
Quick connector for connecting mixed water outlets to flexible hoses. Maximum operating temperature 60°C.
Range of pump docking manifolds with plastic bodies and NBR, EPDM and FKM ‘O’-rings. Maximum working pressure 8.0 bar. Cold water use only.
Stainless steel bodied sensor with EPDM ‘O’-ring. Maximum operating temperature 90°C.
Range of isolation valves incorporating brass bodies and EPDM ‘O’-rings. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.
Range of central heating pumps incorporating polyether sulphone impellers, copper-tin alloy body, carbon graphite axial bearings and EPDM O-rings. Maximum working pressure 16.0 bar. Maximum operating temperature 99°C.
CM(E)(C) range of electronically operated pumps available in stainless steel, (‘EN 1.4301/AISI304’ or ‘EN 1.4401 /AISI316’) and cast iron. (CMEC models were added October 2023). The pumps are supplied with Sic-Sic mechanical shaft seals and FKM or EPDM seals. Cast iron models: Maximum working pressure 10.0 bar. Cold water use only. Stainless steel models: Maximum working pressure 16.0 bar. Maximum operating temperature 60°C for self-priming models, 99°C for all other models.
Range of submersible pumps with stainless steel bodies, impellers and shaft. The XPW range incorporates a strainer cowl on the suction end of the pump. The XPWA range features a stainless head which provides a threaded connection instead of the strainer. Cold water use only.
Range of inline circulating pumps with bronze bodies, plastic impeller and EPDM rubber seals. Maximum working pressure 10.0 bar. Maximum operating temperature 100°C.
Dutypoint ‘VS’ range of cold water supply booster sets, incorporating 2 to 8 pumps with a modular stainless steel manifold system. The booster sets also incorporate spherical valves, non-return valves, pressure switches/sensors and expansion vessels.. Maximum working pressure 10.0 bar. Cold water use only.
Range of positive displacement diaphragm pumps with plastic bodies, EPDM ‘O’-rings and TPE diaphragm. The product incorporates an integral bypass relief valve. For use with John Guest LLDPE Pipe. Maximum working pressure 11.03 Bar (Bypass) and 7.0 Bar (Operating).
Range of shower handsets with a chromium plated plastic body. The inlets incorporate a flow regulator. Maximum operating temperature 60°C.
Ceiling mounted shower outlet consisting of a (chrome plated) brass shower arm and a (chrome plated) stainless steel shower rose with an integral ball joint and silicone nozzles . The connection between the shower arm and the ball joint incorporates a combined EPDM washer and stainless steel strainer. The connection between the ball joint and the overhead shower incorporates a plastic flow regulator. Maximum operating temperature 60°C.
Range of overhead shower outlets with brass bodies (various finishes), with a ball joint, EPDM ‘O’-rings and a NBR seal. The inlet incorporates a plastic flow regulator. Maximum operating temperature 60°C.
Range of Grohe Euphoria 110’ hand showers with chromium plated plastic bodies. The inlet of model 27.221 incoporates a plastic flow regulator. Maximum operating temperature 60°C.
Range of shower handsets, various finishes. All models incorporate a stainless-steel strainer in the inlet. The inlet of model 26 090 also incorporates a plastic flow regulator. Maximum operating temperature 60°C.
Range of shower handsets and shower heads chrome plated plastic bodies and built in combined flow restrictors/approved check valve cartridge however, the complete product has not been fully tested to demonstrate it provides backflow protection. Models added March 2023 are available in various finishes, see model.
Non-metallic materials and components comply with BS6920 at 60°C
Range of shower handsets and shower heads with chromium plated ABS bodies (models A111101 & A121510WT is not chromium plated). Maximum operating temperature 75°C.
Range of overhead shower outlets with chromium plated plastic bodies. Models SD1062 and SD1064 incorporate stainless steel strainers in the inlets. Maximum working temperature 75°C.
A self-closing shower handset with a plastic body, the inlet incorporates a plastic flow restrictor and an approved check valve cartridge, however, the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum working pressure 6.0 bar. Maximum operating temperature 85 °C.
Range of shower handsets with chromium plated plastic bodies. Maximum operating temperature 75°C.
Shower handset incorporating a chromium plated plastic body. Maximum operating temperature 65°C.
Range of drain off taps incorporating DZR brass bodies, non-rising spindle operating mechanism and EPDM ‘O’-rings and seat washer. FIG 371 range incorporates a lockshield mechanism and the FIG 370 range incorporates a key operated mechanism. Maximum working pressure 16.0 bar. Maximum operating temperature 85°C.
Range of wall mounted non concussive shower valves with either a concealed or exposed brass body and chrome plated trim. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.
Range of self-closing basin taps (chromium plated brass) with spring loaded headwork and dome type operating members. The spout outlets incorporate a plastic aerator and the products are supplied with metal backnuts. Maximum working pressure 5.0 bar. Maximum operating temperature 60⁰C.
Range of stainless steel braided PE-X lined flexible hose assemblies incorporating NBR washers and various end connections. Maximum working pressure 10.0 bar. Maximum operating temperature 85°C.
Range of stainless steel braided EPDM lined hose assemblies with EPDM O-rings and some models incorporate a servicing valve. Maximum working pressure 6.0 bar. Maximum operating temperature 65°C.
Wall mounted, exposed manual blending valve with brass body (various finishes) incorporating a ceramic cartridge headwork, which controls both temperature and flow and has a single lever operating member. Both inlets incorporate an approved check valve cartridge, however, the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum working pressure 10.0 bar. Maximum operating temperature 70°C.
Range of wall mounted, flow control valves with brass bodies and various trim sets (various finishes). Flow is controlled to the outlets via a push to on push to off ‘detent’ headwork. Maximum Working Pressure 10.0 bar. Maximum operating temperature 70°C.
Range of thermostatic mixing valves incorporating brass bodies (chrome plated). The flow is controlled by quarter turn ceramic disc headwork, with dome or cube type operating members, which also diverts the flow between multiple shower outlets. The temperature is controlled by a thermostatic cartridge with dome or cube type operating members. Both inlets incorporate stainless steel strainers and approved check valve cartridges, however, the complete products have not been fully tested to demonstrate that they provide backflow protection. The products are supplied with a shower hose, shower handset and overhead shower outlet. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.
Range of two way and three way concealed thermostatic shower valves, incorporating brass bodies and ceramic disc headwork with dome type operating members which controls the flow and diverts to various shower outlets. Temperature is controlled by a thermostatic cartridge incorporating a manual over ride button. Inlets incorporate stainless steel filters and an approved single check valve cartridge (however the complete assembly has not been tested to demonstrate it provides adequate backflow protection). Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.
Range of concealed thermostatic mixing valves, incorporating quarter turn ceramic disc headworks, with dome type operating members, controlling the flow to multiple shower outlets. The temperature is controlled independently via a thermostatic cartridge with dome type operating member. The inlets incorporates stainless steel strainers an approved check valve cartridge however, the complete product has not been fully tested to demonstrate it provides backflow protection Maximum working pressure 5.0 bar. Maximum operating temperature 60°C
Range of wall mounted, bar type thermostatic shower valves (chromium plated brass), incorporating a ceramic disc headwork which controls and diverts the flow between two outlets (shower to shower) and off position with a cube type operating member (model C76086-05 ) or dome type operating member (model C26037-03). The temperature is controlled independently via a thermostatic cartridge with a cube type operating member incorporating a manual override button (model C76086-05 ) or dome type operating member incorporating a manual override button (model C26037-03). Both inlets incorporate stainless steel filters and a single check valve cartridge however the complete assembly has not been tested to demonstrate it provides adequate backflow protection. The valves are supplied with a shower hose, shower handset and fixed overhead shower rose. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.
Wall mounted, bar type thermostatic shower mixers (chromium plated brass), incorporating a quarter turn ceramic disc headwork controlling the flow with single lever operating members. The temperature is controlled independently via a thermostatic cartridge with single lever operating members. Both inlets incorporate a stainless steel strainer and a single check valve cartridge, however the complete assembly has not been tested to demonstrate it provides adequate backflow protection. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.
Range of 1, 2 or 3 outlet concealed wall mounted bar type thermostatic mixer valve (various finishes) incorporating a quarter turn ceramic disc headwork controlling the flow using a single lever or cross top operating member depending on the model type. The temperature is controlled independently via a thermostatic cartridge also using a cross top or single lever type operating member (Depending on model). Inlets incorporate stainless steel strainers and approved single check valve cartridges, however, the complete product has not been fully tested to demonstrate it provides backflow protection. some models are supplied with a shower handset and hose. Maximum working pressure 5.0 bar. Maximum operating temperature 65.0°C
Range of thermostatic mixing valves with between 1 and 6 outlets. Flow is controlled by a solenoid valve and temperature is thermostatically controlled. Models Mira Activate 1.1903.091, 1.1903.092 & 1.1903.093 incoporate a built-in pump which is set 12 litres per minute. The valves can be supplied with a shower rail, hose, handshower and/or ceiling mounted shower outlet. The inlets of the valves incorporate an isolation valve, stainless steel strainer and a single check valve cartridge however, the complete assembly has not been tested to demonstrate it provides adequate backflow protection. Valves with ‘HP’ in model have a maximum working pressure of 5.0 bar. All other valves have a maximum working pressure of 1.0 bar. Maximum operating temperature 50°C.
Range of wall mounted bar type thermostatic shower mixers (chromium plated brass) incorporating a ceramic disc headworks controlling the flow. Temperature is controlled via a thermostatic cartridge with single lever type operating members which incorporate manual override buttons. The inlets incorporate a stainless-steel strainer and an approved check valve cartridge; however, the complete products have not been fully tested to demonstrate that they provide backflow protection. Products are supplied with a shower hose, shower handset, riser rail and soap dish. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.
Range of lugged butterfly valves with blue, black or red epoxy coated ductile iron bodies and nickel plated ductile iron discs and an EPDM sealing ring. D71XLK models are lever operated, the D371XLK are handwheel operated. Maximum working pressure 16.0 bar. Maximum operating temperature 85°C.
Range of handwheel & gear operated butterfly valves with blue epoxy coated ductile iron bodies and discs and EPDM rubber seat. Maximum working pressure 16.0 bar. Cold water use only.
2-way ceramic disc rotary diverter valve with a plastic body and silicon seals. For insertion into specifically dimensioned bodies. Maximum working pressure 10.0 bar. Maximum operating temperature 65°C.
Range of ‘J2 10 series’ of equilibrium float valves with cast iron (epoxy coated) bodies and EPDM seals. Available with either standard or extended arms. Maximum working pressure 10 bar. Cold water use only.
Range of flow control valves with blue epoxy coated ductile Iron bodies and EPDM ‘O’-rings. Auxiliary components include stainless steel tube with fittings and ball valves. Maximum working pressure 16.0 bar. Maximum operating temperature 50°C.
Range of in-line adjustable pressure reducing valves with Nickel plated DZR brass bodies and EPDM gaskets. Maximum inlet supply pressure 16.0 bar. Outlet pressure in the range of 0.5 bar to 6.0 bar. Maximum operating temperature 80°C.
Range of in-line adjustable pressure reducing valves, with DZR brass bodies and EPDM seat washers & ‘o’ rings and stainless-steel filters. Various models supplied with pressure gauge (please see model list). Maximum inlet supply pressure 16.0 bar. Outlet pressure range: 0.8-6.0 bar. Maximum operating temperature 80°C.
Range of pilot operated pressure reducing valves with blue epoxy coated ductile iron bodies, stainless steel filter, EPDM ‘O’-rings and diaphragm. The valve has an adjustable pressure reducing facility controlled via a pilot valve, with auxiliary components including stainless steel tubing and fittings, and stainless-steel spherical valves. Maximum inlet supply pressure 16.0 bar. Outlet pressure setting is adjustable in the range of 0.6 - 6.0 bar. Maximum operating temperature 50°C.
Range of pilot operated pressure reducing valves with blue epoxy coated ductile iron bodies, stainless steel filter, EPDM ‘O’-rings and diaphragm. The valve has an adjustable pressure reducing facility controlled via a pilot valve, with auxiliary components including stainless steel tubing and fittings, and stainless steel spherical valves. Maximum inlet supply pressure 16.0 bar. Outlet pressure setting is adjustable in the range of 0.6 - 6.0 bar. Maximum operating temperature 50°C.
Range of motorised spherical valves with stainless steel bodies, ball and PTFE seals Maximum working pressure 16.0 bar. Maximum operating temperature 99˚C.
Range of spherical valves with a brass body brass ball (chrome plated), PTFE gaskets, EPDM ‘O’-rings and a single lever operating member. Maximum working pressure 10.0 bar. Maximum working temperature 100°C.
Range of spherical ball valves with lever or tee operating member, brass bodies, chromium plated brass ball and PTFE seat. Maximum working pressure 50.0 bar: ¼” (DN 8), 3/8” (DN 10) & ½” (DN 15). Maximum working pressure 40.0 bar: ¾” (DN 20) & 1” (DN 25). Maximum working pressure 30.0 bar: 1¼” (DN 32) & 1½” (DN 40). Maximum working pressure 25.0 bar: 2” (DN 50). Maximum operating temperature 60°C.
Range of in line spherical valves incorporating chrome plated brass bodies, chrome plated brass ball, NBR ‘O’-rings and PTFE seals. Model 825212 incorporates a single lever operating member, models 825015 and 8250152 have no operating members. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.
Range of spherical valves incorporating brass bodies and balls (nickel plated), EPDM rubber ‘O’-rings, PTFE seats and red or blue coloured lever type operating members. Maximum working pressure 10.0 bar. Maximum operating temperature 65°C.
Range of gate valves incorporating bronze bodies and wedges with PTFE seals. The valves are operated via a non-rising spindle with a hand wheel operating member. Maximum working pressure 20.0 bar. Maximum operating temperature 85°C.
Range of gate valves with blue epoxy coated ductile iron bodies, EPDM coated ductile iron wedges. The valves operate via a non-rising spindle headwork with hand wheel operating member. Maximum working pressure 16.0 bar. Maximum operating temperature 85°C.
Range of gate valves with blue epoxy coated ductile iron bodies, EPDM coated ductile iron wedges. The valves operate via a non-rising spindle headwork with hand wheel operating member. Maximum working pressure 16.0 bar. Maximum operating temperature 85°C.
Range of gate valves incorporating a blue epoxy coated ductile iron body. EPDM coated ductile iron wedges and a non-rising spindle headwork. Maximum working pressure 16.0 bar. Maximum operating temperature 45°C. As of September 2024 Maximum operating temperature 23°C.
Range of screw down stop valves incorporating brass bodies and EPDM gaskets. Maximum working pressure 16.0 bar. Maximum working temperature 80°C.
Range of screw down angle valves (chromium plated brass) incorporating a dome (triangular) type operating member with a NBR rubber washer. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.
Range of bedpan washers with the flow controlled by a solenoid valve and discharged via a type `AB` airgap (verified by test - suitable for backflow protection against fluid category 5). Maximum working pressure 6.0 bar. Maximum operating temperature 60°C
Range of ultra-violet disinfection units consisting of a stainless-steel body and quartz tubes with EPDM O rings. Maximum working pressure 16.0 bar. Maximum operating temperature 50.0°C
'Aixin Powder Coating RAL 5015 Blue'. Factory applied, blue coloured EP coating comprising of base, hardener, pigment, filler and additive agent. The base, hardener, pigment, filler and additive agent were mixed in a 60:12:10:17:1 mass ratio. Cure for 15 minutes@200°C. For use with water up to 85°C. This material is only approved for the mixing and curing conditions that appear on the approval. If the mixing and/or curing conditions are varied from those specified on the approval then the materials are not covered by the scope of the approval.
'Eurokote® 46-60 Red Brown'. Factory applied, red-brown coloured epoxy coating. Apply as per manufacturer's technical data sheet dated 19/11/2019. Cure for 7 days@20°C. For use with water up to 60°C. This material is only approved for the curing conditions that appear on the approval. If the cure conditions are varied from those specified on the approval then the material is not covered by the scope of the approval.
'EPY2-II'. Factory applied, blue coloured epoxy powder coating. Apply as per manufacturer's user instruction 'REV-202012-2' dated '11.12.2020'. Cure for 7 minutes@180°C. For use with water up to 65°C. This material is only approved for the curing conditions that appear on the approval. If the cure conditions are varied from those specified on the approval then the material is not covered by the scope of the approval.
'SC4'. Factory applied, clear PTFE coating, intended for use with `O` rings, seals & gaskets. Apply as `Superior Group Quality Management System Procedure Reference 8.6’ referenced in document `LDAP-008 issue 1` released 01/05/2020. For use with water up to 85°C
'SYI-03'. Factory applied, grey coloured, Portland cement mortar. Mix cement, sand and water in a mass ratio of 1:1.5:0.6. Cure for 4 hours@23°C. For use with water up to 65°C. This material is only approved for the mixing and curing conditions that appear on the approval. If the mix and/or cure conditions are varied from those specified on the approval then the material is not covered by the scope of the approval.
'HPL 2510 PW'. Factory applied, two-component epoxy coating comprising of a base and hardener. Mix base and hardener in a weight ratio of 2.78:1. Cure for 7 days@30°C. For use with water up to 65°C. This material is only approved for the mixing and curing conditions that appear on the approval. If the mix and/or cure conditions are varied from those specified on the approval then the material is not covered by the scope of the approval.
‘Crystic 3846 BE (transparent, brown coloured) & Crystic 491 EPA (ME)’ Transparent, brown coloured and translucent, pale yellow coloured, contact moulded GRP materials. For use with water up to 23°C.
'Badadur PBT9 GF30 graphit 371 (grey coloured) & Badadur PBT9 GF30 Alpinweiss 230c (white coloured). Injection moulded Polybutylene terephthalate (30% glass fibres) materials. For use with water up to 65°C.
'Magnum 3G Compression Fitting Body'. Black coloured, injection moulded polypropylene fitting body. For use with water up to 60°C.
'kSil GP40 - GP-70'. Extruded, silicone rubber material available in translucent (which appears off-white), black, white, red and blue colours. Shore hardness between 40 & 70. Tested in-radii sizes between 0.15mm & 6.0mm. For use with water up to 85°C.
Range of single hole, single outlet (fixed) electronically operated, tap assemblies (chromium plated brass). Flow is controlled via solenoid valve and actuated by a touch sensor. The spout outlets incorporate a plastic aerator, supplied with stainless steel strainers. Maximum working pressure 8.0 bar. Maximum operating temperature 60°C.
Single hole, single outlet (fixed) combination tap assembly (stainless steel). The flow is controlled by a solenoid valve that is actuated via an infra-red sensor on the spout. The inlet to the solenoid valve incorporates a stainless steel strainer. The spout outlet incorporates a plastic aerator. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.
Range of wall mounted, two hole, single outlet (fixed) mains electric or battery controlled tap assemblies (chromium plated brass) incorporating approved check valve cartridges however, the complete product has not been fully tested to demonstrate it provides backflow protection . The flow is controlled via a solenoid valve activated via an infra-red sensor. The inlet to the solenoid incorporates a stainless-steel strainer. The tap is supplied with spherical valves for both hot and cold inlets. The spout outlet incorporates a plastic aerator. Maximum working pressure 5.0 bar. Maximum operating temperature 65°C.
Single hole, single outlet, fixed electronically controlled tap assemblies with brass bodies (chrome plated), incorporating a solenoid valve controlling the flow which is activated via an infrared sensor. The spout outlet incorporates a plastic aerator, and the product is supplied with a metal backnut. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.
Range of wall mounted, electronically controlled spout outlets with stainless steel bodies. Flow is controlled via a solenoid valve activated via an infra-red sensor. Models AT07-102 and AT07-103 are supplied with a plastic aerator. Maximum working pressure 8.0 bar. Maximum operating temperature 60°C.
Side entry BS1212-4 (2016) compact type float operated valve for WC flushing cisterns. The inlet incorporates a strainer. Maximum working pressure 10.0 bar. Cold water use only.
Side entry BS1212-4 (2016) compact type float operated valve for WC flushing cisterns. The inlet incorporates a plastic filter. Maximum working pressure 10.0 bar. Cold water use only.
Range of bottom entry BS1212-4 (2016) compact type float operated valves for WC flushing cisterns with delayed action. . The inlet incorporates a flow restrictor. Maximum working pressure 10.0 bar. Cold water use only.
Range of bottom entry BS1212-4 (2016) compact type float operated valves for WC flushing cisterns. The inlet incorporates a plastic strainer. Maximum working pressure 10.0 Bar. Cold water use only.
WC flushing cistern incorporating a side entry compact type float operated inlet valve providing a Type AG air gap with a dual flush drop valve for full flush volumes of up to 6 litres and a reduced flush of up to 4 litres. The cistern is operated by a manual push button and incorporates a servicing valve on the inlet supply. Maximum working pressure 10.0 bar. Cold water use only.
WC flushing cistern incorporating a side entry compact type float operated inlet valve providing a Type AG air gap with a dual flush drop valve for full flush volumes of up to 6 litres and a reduced flush of up to 4 litres. The cistern is operated by a manual push button and incorporates a servicing valve on the inlet supply. Maximum working pressure 10.0 bar. Cold water use only.
WC flushing cistern incorporating a side entry compact type float operated inlet valve providing a Type AG air gap with a dual flush drop valve for full flush volumes of up to 6 litres and a reduced flush of up to 4 litres. The cistern is operated by a manual push button and incorporates a servicing valve on the inlet supply. Maximum working pressure 10.0 bar. Cold water use only.
Spring loaded, resilient trim, in-line check valve cartridges with plastic body. For insertion into pipes and fittings with specifically dimensioned bores. Maximum working pressure 10.0 bar. Maximum operating temperature 85°C.
OV & OF ranges of spring loaded, resilient trim, in-line check valve cartridges within a plastic housing. For insertion in pipes and fittings with specifically sized bores. Maximum working pressure 16.0 bar. Models OF10/DN8 - 31.4208.0 & OF10/DN8-EPDM - 31.0059 have a maximum operating temperature of 60°C. Model OV10/DN8 – 31.4210.0 has a maximum operating temperature of 85°C.
Range of non-verifiable double check valve assemblies consisting of two spring loaded resilient trim in-line check valve cartridges housed in a DZR brass body, compression models are nickle plated. A drain port is provided between the cartridges. Compression models are to be used with copper pipe to EN1057. Maximum working pressure 16.0 Bar. Maximum operating temperature for the Hattersley Fig 250W range 85°C. Maximum operating temperature of the Hattersley Fig 250CW is 60°C
Range of single hole bidet taps with brass bodies (various finishes) and swivel spout outlets. The products incorporate a ceramic cartridge headwork with single lever operating members. The spout outlets incorporate a plastic aerator and the products are supplied with a lever operated waste. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.
Range of ceramic disc diverter valve headworks with plastic bodies for use in specifically dimensioned bodies. Maximum working pressure 10.0 bar. Maximum operating temperature 85°C.
Single hole, single outlet (swivel) combination tap assembly (chromium plated brass) incorporating a ceramic cartridge headwork with a single lever operating member. The product incorporates a pull-out spout with a plastic aerator, which also incorporates an approved single check valve cartridge, however, the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.
Range of single hole, single outlet (fixed) combination tap assemblies (chromium plated brass bodies), incorporating ceramic cartridge headworks with single lever operating members. The spout outlet of models SAV2113/SHD113/SEV113 incorporates plastic aerators. SPA2113 and SPA2313 incorporate a stainless steel mesh at the spout. SAVV2113, SHD113, SEV113, SPA2113, SWO2113 are supplied with a pop-up waste. Maximum working Pressure 10.0 bar. Maximum operating temperature 65ºC.
Range of single hole, single outlet, (fixed) combination tap assemblies with brass bodies (chromium plated), incorporating a ceramic cartridge headworks with single lever operating members. The spout outlet incorporates a plastic aerator and is also supplied with an optional flow straightener. Some products are supplied with a lever type pop-up waste (see models). Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.
Single hole, single outlet fixed combination tap assembly (chrome plated brass), incorporating non-rising spindle headworks. The spout outlet incorporates a plastic flow straightener. Supplied with a pop-up waste. Maximum operating pressure 5.0 bar. Maximum operating temperature 60°C
Single hole, single outlet fixed combination tap assembly (chrome plated brass), incorporating non-rising spindle headworks with cross type operating members. The spout outlet incorporates a plastic flow straightener. Supplied with a pop-up waste. Maximum operating pressure 5.0 bar. Maximum operating temperature 60°C
Single hole, single outlet (fixed) combination tap assembly (chromium plated brass) incorporating ceramic cartridge headwork with single lever operating member. The spout outlet incorporates a plastic aerator. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C
Single hole, single outlet (fixed) combination tap assembly (chromium plated brass) incorporating ceramic cartridge headworks and single lever operating members. The spout outlet incorporates a plastic aerator. Maximum working pressure 10.0 bar. Maximum operating temperature 70ºC.
Range of single hole, single outlet (fixed) combination tap assemblies (chromium plated brass), incorporating ceramic cartridge headworks with single lever operating members. The spout outlets incorporate a plastic aerator. Models 23472W-4-CP and 23475W-4-CP are supplied with a pop-up waste. Maximum working pressure 5.0 bar. Maximum operating temperature 60ºC.
Range of single hole, single outlet (fixed) combination tap assemblies incorporating brass bodies (chrome plated) and ceramic cartridge headwork with single lever operating members. The spout outlets incorporate a plastic aerator. Models 74013W-4AB-CP and 74026W-4AB-CP are supplied with a pop up waste . Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.
Range of wall mounted single hole, single outlet (fixed) combination tap assemblies with brass bodies (various finishes) incorporating a touchless operation method which operates a solenoid valve which controls the flow and is connected via a hose to the spout outlet. The spout outlets incorporate a plastic aerator. Maximum working pressure 3.0 bar. Maximum operating temperature 60°C.
Single hole, single outlet fixed combination tap assembly (chrome plated brass), incorporating a ceramic cartridge headwork with a single lever operating. The spout outlet incorporates a plastic aerator or flow straightener. Maximum operating pressure 5.0 bar. Maximum operating temperature 60°C
Range of single hole, single outlet (fixed) combination tap assemblies (various finishes), incorporating a ceramic cartridge headwork with single lever operating member. The spout outlets incorporate a plastic aerator. Models 10 102 xxx & 10 103 xxx are supplied with a lever operated pop-up waste. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.
Range of single hole, single outlet, (fixed) combination tap assemblies (chromium plated brass), incorporating a ceramic cartridge headworks with a single lever operating member. The inlets incorporate plastic strainers and an approved check valve cartridge however, the complete product has not been fully tested to demonstrate it provides backflow protection. The inlets of ‘2820’ incorporate a spherical valve. The spout outlets incorporate a plastic flow straightener and the products are supplied with a pop-up waste. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.
Range of single hole, single outlet (fixed) combination tap assemblies (chromium plated brass), incorporating ceramic cartridge headworks with a single lever operating member. The inlets of model 2820 incorporates a flow restrictor and spherical valves. The spout outlets incorporate a plastic flow straightener and the products are supplied with a pop-up waste. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.
Range of single-hole single outlet (fixed) combination tap assemblies with brass bodies (various finishes) incorporating ceramic cartridge headwork with single lever operating members. The spout outlets incorporate a plastic aerator and some models are supplied with pop-up wastes. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.
Range of wall mounted single hole, single outlet (fixed) combination tap assemblies with brass bodies (various finishes) incorporating a touchless operation method which operates a solenoid valve which controls the flow and is connected via a hose to the spout outlet. The spout outlets incorporate a plastic aerator. Maximum working pressure 3.0 bar. Maximum operating temperature 60°C.
Range of single hole, single outlet (swivel) combination tap assemblies with brass bodies (various finishes), incorporating ceramic cartridge headworks and single lever operating members. The spout outlets incorporate a plastic aerator. Maximum working pressure 8.0 bar. Maximum operating temperature 60°C.
Single hole, single outlet (swivel) combination tap assembly (chrome plated brass), incorporating quarter turn ceramic disc headwork. The spout outlet incorporates a plastic flow straightener and the product is supplied with single check valve assemblies (verified by test as suitable for backflow protection against Fluid Category 2) with integral servicing valve for both inlets. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C
Single hole, single outlet (swivel) combination tap assembly (chrome plated brass), incorporating quarter turn ceramic disc headwork. The spout outlet incorporates a plastic flow straightener and the product is supplied with single check valve assemblies (verified by test as suitable for backflow protection against Fluid Category 2) with integral servicing valve for both inlets. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C
Range of single hole, single outlet (swivel) combination tap assemblies (chrome plated brass), incorporating quarter turn ceramic disc headwork. The spout outlet incorporates a plastic flow straightener and the product is supplied with single check valve assemblies (verified by test as suitable for backflow protection against Fluid Category 2) with integral servicing valve for both inlets. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C
Range of single hole, single outlet (swivel) combination tap assemblies (brushed nickle or chrome plated brass), incorporating a ceramic cartridge headwork with a single lever operating member. The spout outlet incorporates a plastic flow straightener. Supplied with single check valve assemblies (verified by test as suitable for backflow protection against Fluid Category 2) with integral servicing valve for both inlets. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C
Range of single hole, single outlet (swivel) combination tap assemblies (chrome plated or brushed nickel coated brass), incorporating quarter turn ceramic disk headworks and single lever operating members . The spout outlet incorporates a plastic aerator. Supplied with single check valves with integral servicing valve for both inlets. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C
Range of single hole, single outlet (swivel) combination tap assemblies (stainless steel bodies). The flow of hot and cold water is controlled by a ceramic cartridge headwork with single lever operating member. The flow of filtered water (filter not supplied) is controlled by a quarter turn ceramic disc headwork with a single lever operating member The spout outlets incorporate a plastic aerator. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.
Single hole, single outlet (swivel) combination tap assembly (chromium plated brass) incorporating quarter turn ceramic disc headworks with single lever operating members. The spout outlet incorporates a plastic aerator. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.
Range of single hole, single outlet, (swivel) combination tap assemblies incorporating brass bodies (chromium plated) and quarter turn ceramic disc headworks with single lever operating members. The spout outlets incorporate a plastic aerator. Maximum working pressure 6.0 bar. Maximum operating temperature 60°C.
Single hole, single outlet (swivel) combination tap assembly (chromium plated brass) incorporating ceramic cartridge headwork with single lever operating members. The spout outlet incorporates a plastic aerator. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.
Single hole, single outlet (swivel) combination tap assembly (chromium plated brass), incorporating a ceramic cartridge headwork with a single lever operating member. The spout outlet can incorporate either a plastic flow straightener or a plastic aerator. When supplied with a plastic flow straightener there is a combined EPDM washer and stainless steel strainer behind it. Maximum working pressure 10.0 bar. Maximum operating temperature 70°C.
Range of single hole, single outlet (swivel) combination tap assemblies (chromium plated brass) incorporating ceramic cartridge headworks with single lever operating members. The spout outlets incorporate a plastic aerator. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C
A range of single-hole, single outlet, (swivel) combination tap assemblies (various finishes), incorporating ceramic cartridge headworks with single lever operating members. The spout outlets incorporate a plastic aerator. Models 71554XXX and 71564XXX are supplied with pop-up wastes. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.
A single-hole single outlet swivel combination tap assembly (chromium plated brass) incorporating a ceramic cartridge headwork with a single lever operating member. The outlet incorporates a plastic aerator. Maximum working pressure 10.0 bar. Maximum working temperature 60°C.
A range of single hole single outlet (swivel) combination tap assemblies (chromium plated brass) incorporating either ceramic cartridge or quarter turn ceramic disc headwork with a single lever, cross top or dome type operating member. The spout outlets incorporate either a plastic flow straightener or aerator. Model SH-T81072 is supplied with metal back nuts. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C
Range of single hole, single outlet (swivel) combination tap assemblies (chromium plated brass) incorporating a rising spindle headwork with a single lever operating member. The spout outlets incorporate a plastic flow straighter and the products are supplied with metal backnuts. Maximum working pressure 10.0 bar. Maximum operating temperature 65°C.
Wall mounted, single hole, single outlet (swivel) combination tap assembly (chromium plated brass), incorporating a rising spindle headwork with a single lever operating member. The spout outlets incorporate a plastic flow straighter and the products are supplied with metal back nuts. Maximum working pressure 10.0 bar. Maximum operating temperature 65°C.
Single hole, single outlet (swivel) combination tap assemblies (chromium plated brass), incorporating a ceramic cartridge headwork with a single lever operating member The spout outlets incorporate a plastic aerator. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.
Range of single hole, single outlet (swivel) combination tap assemblies (various finishes) with ceramic cartridge headworks and single lever operating members. The discharge is via the hand spray outlet or the infra-red controlled outlet on the swivel arm. The cold Inlet has a single check valve assembly (suitable for protection against fluid category 2 backflow). The spouts incorporate a plastic aerator. Maximum operating pressure 5.0 bar. Maximum operating temperature 60°C.
Range of single hole, double outlet (fixed) combination tap assemblies (various finishes) with electronically controlled functions to allow the tap to dispense boiling water, chilled water or sparkling water from under counter units (not supplied). The spout outlet of ‘Arc’ models incorporates a plastic flow straightener. All models incorporate a separate vent outlet within the tap spout for the near-boiling water circuit. Near-boiling circuit has a maximum operating temperature 100°C. Hot-water circuit has a maximum operating temperature of 65°C.
Wall mounted, two hole, single outlet (fixed) combination tap assemblies (chromium plated brass). Incorporating ceramic disk headwork and dome type operating members. The spout outlets incorporate a plastic aerator. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.
Range of single hole, deck mounted, single outlet (fixed) electronically controlled combination tap assemblies with brass bodies (various finishes), flow is controlled by a solenoid valve activated via an infra-red sensor. Some models have a pre set temperature.. Inlets incorporate stainless steel strainers and single check valve cartirdges however, the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum working pressure 5.0 bar. Maximum operating temperature 85°C.
Range of two hole, wall mounted single outlet (fixed) electronically controlled combination tap assemblies with brass bodies (various finishes), flow is controlled by a solenoid valve activated via an infra-red sensor. Some models have a pre set temperature. Inlets incorporate stainless steel strainers and approved check valve cartridges however, the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum working pressure 5.0 bar. Maximum operating temperature 85°C.
Two hole, single outlet fixed combination tap assembly (chrome plated brass) incorporating a ceramic cartridge headwork and a single lever operating member. The tap body and spout oulet are connected via a stainless steel braided EPDM lined flexible hose. The spout outlet incorporates a plastic aerator. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.
Two hole, single outlet (fixed), combination tap assembly (chromium plated brass) incorporating quarter turn ceramic disc headworks with single lever operating members. The spout outlet incorporates a plastic flow straightener and the product is supplied with metal backnuts. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.
Wall mounted, two-hole, single outlet (fixed) combination tap assembly (chromium plated brass), incorporating a quarter turn ceramic cartridge headwork with single lever operating member. Both inlets incorporate eccentric isolation valves and plastic flow regulators. The spout outlets incorporate plastic flow straighteners. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.
Range of two-hole, single outlet, (swivel) combination tap assemblies (chrome plated brass) incorporating a ceramic cartridge headwork with single lever type operating members. The spout outlets incorporate a plastic aerator. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.
Range of two-hole, single outlet (swivel) combination tap assemblies (chromium plated brass), incorporating rising spindle headwork with single lever operating members. The spout outlets incorporate a plastic flow straightener. Maximum working pressure 10.0 bar. Maximum operating temperature 65°C.
Range of wall mounted, three-hole, single outlet (fixed) combination tap assemblies (brass body with various finishes) incorporating quarter turn ceramic disc headworks with cross top type operating members. The spout outlets incorporate a plastic aerator. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.
Range of wall mounted, concealed, three hole, single outlet (fixed) combination tap assemblies with brass bodies (various finishes, see model). Incorporating a ceramic cartridge headwork with single lever operating member and a self-cancelling diverter, diverting the flow between the shower outlet and the bath outlet. The spout outlet incorporates a flow straightener and Incorporates approved check valve cartridge however, the complete product has not been fully tested to demonstrate it provides backflow protection. Also supplied with shower handset and hose. Handset incorporates a flow regulator. Maximum working pressure 5.0 Bar. Maximum operating temperature 60°C.
Range of four-hole, single outlet (fixed) combination tap assemblies (various finishes), incorporating quarter turn ceramic disc headworks with single lever or cross top operating members and a self-cancelling diverter to shower outlet. The spout outlets incorporate a plastic aerator. The products are supplied with a shower hose and the hose connector incorporates approved check valve cartridge however, the complete product has not been fully tested to demonstrate it provides backflow protection. Not supplied with a shower handset. Maximum working pressure 5.0 bar Maximum operating temperature 60°C
A range of combined bath filler and overflow with a plastic body with a variety of different trims. The products are supplied with a cable operated pop-up waste. For open outlet use only. Maximum operating temperature 65°C.
Bath spout with brass body (chromium plated). The outlet incorporates a plastic aerator. Maximum operating temperature 60°C.
Range of chemical dosing equipment which incorporate self-closing valves with a plastic body. The outlet of the injector incorporates a connection for injection of chemicals via venturi action. Maximum working pressure 9.0 bar. Maximum operating temperature – 60ºC
Range of water filter systems with optional distributor heads. The inlets incorporate a non-return valve. Maximum working pressure 6.9 bar. Cold water use only.
Range of complete water filter heads and compatible filter cartirdges with plastic bodies and EPDM ‘O’-rings. The FX filters are carbon block based and the VH-IEN filters use an ion exchange resin. Maximum working pressure 8.6 bar. Cold water use only.
‘Numepress’ range of stainless-steel crimp fittings incorporating EPDM and ‘O’-rings. For use with stainless steel tube. Maximum working pressure 16.0 bar. Maximum operating temperature 95°C.
‘Epsilon Series’ polypropylene bodied compression fittings with EPDM ‘O’-rings for use with Elysee PE80 blue pipes. The fittings are supplied with a pipe liner. Above and below ground use. Maximum working pressure 12.5 bar. Cold water use only.
Range of press fittings with a stainless steel body and EPDM ‘O’ rings for use with stainless steel 316L pipe manufactured to EN10312. For above ground use only. Maximum working pressure 16.0 bar. Maximum operating temperature 85°C.
Range of brass and copper fittings for use with EN 1057 copper tube. For above ground use only. Maximum working pressure 18.6 bar. Maximum operating temperature 100°C.
Dual flush, WC outlet valves. Model A2706 is operated via a push button assembly for either full or reduced flush. Models A2415L & A2415M are not supplied with a operating button. Maximum operating temperature. Cold water use only.
Range of waste water heat recovery systems incorporating a twin wall copper coil (iZi models) or stainless steel (PiPe models). Maximum working pressure 10.0 bar. Cold water use only.
Range of indirect heat interface units with copper brazed stainless-steel heat exchangers, providing heating and instantaneous hot water. The products incorporate an expansion vessel on the cold-water supply to the plate heat exchanger and a safety relief valve on the space heating circuit set @ 3.0 bar. The domestic hot water and space heating circuit are both fitted with drain valves incorporating cover caps. Maximum working pressures: Domestic hot water 10.0 bar. Space Heating 2.5 bar. District Heating 3.0 bar. Maximum operating temperature 85˚C.
Range of stainless-steel heat exchangers. Maximum working pressure of primary Circuit 3.0 bar. Maximum working pressure of secondary Circuit 10.0 bar. Maximum operating temperature 80˚C
Electronically controlled heat interface units (HIU) with twin stainless-steel plate heat exchangers providing space heating and instantaneous hot water. The cold inlet supply to the plate heat exchanger incorporates an isolation valve and a water hammer arrestor. The space heating circuit incorporates an expansion vessel and a pressure relief valve (set at 3.0 bar). The product is supplied with a filling loop assembly consisting of an elbow shaped copper pipe, isolation valve and double check valve assembly (suitable for backflow protection against fluid category 3) which incorporates an isolation valve. The cold mains inlet and the domestic hot water outlet each incorporate a brass bodied spherical valve with a butterfly handle. Maximum working pressures and operating temperatures: Primary: 16.0 bar and 90˚C. Domestic hot water (DHW): 10 bar and 65˚C. Secondary (space heating): 2.5 bar and 85˚C.
Range of RINNAI continuous flow water heaters with stainless steel plate heat exchangers providing heating and instantaneous hot water .The hot water is generated via a plate heat exchanger. Also supplied is a drain valve and a flow sensing device. Maximum working pressure - 10 bar Maximum working pressure - 85˚C
Gas fired water heaters incorporating a heat exchanger and flow sensor. The inlet incorporates a plastic strainer. The products are supplied with isolation valves for installation on the cold inlet and hot outlet. Maximum working pressure 10.0 bar. Maximum operating temperature 60˚C
Range of wall mounted combination boilers providing domestic hot water via a plate heat exchanger and pressurised central heating system, incorporating a pressure relief valve set at 3.0 bar and expansion vessel on the primary circuit. The inlet of the replenishing valve between the primary and secondary circuits incorporate a plastic strainer. Maximum working pressure 2.5 bar (primary) and 6.0 bar (secondary). Maximum operating temperature 85˚C.
LCB700 range of internal and external oil-fired condensing combination boilers providing domestic hot water and pressurised central heating via a plate heat exchanger. The products are supplied with a temporary filling loop which incorporates a combined isolation valve and double check valve assembly (suitable for backflow protection against Fluid Category 3), stainless steel braided EPDM lined flexible hose assembly and an isolation valve. The primary (space heating) circuit incorporates an expansion vessel and a pressure relief valve (set at 3.0 bar). Operating parameters: Primary (space heating) circuit: Maximum working pressure 2.5 Bar. Maximum operating temperature 105°C. Secondary (DHW) circuit: Maximum working pressure 10.0 Bar. Maximum operating temperature 85°C.
Range of heat interface units (HIU) with either twin or single stainless steel copper brazed plate heat exchangers (depending on model) providing heating and hot water (twin unit) hot water only, or heating only. The hot water is generated via a plate heat exchanger. The primary (space heating) circuit incorporates an expansion vessel and a pressure relief valve (set at 3.0 bar). The product incorporates a CAb backflow prevention device (suitable for backflow protection against Fluid Category 3) for filling the heating circuit. The inlet and outlet of all circuits incorporate a lever operated spherical valve. Maximum working pressures and operating temperatures: Primary (district heating): 10.0 bar and 85˚C. Domestic hot water (DHW): 10.0 bar and 60˚C. Secondary (space heating): 2.5 bar and 80˚C.
Range of water meters with plastic or brass bodies. The inlets incorporate a plastic strainer. Maximum working pressure 16.0 bar. RTKD range has a maximum operating temperature of 50°C. RTKD-L range has a maximum operating temperature of 30°C.
Ultrasonic water meter with a blue epoxy coated ductile iron body and EPDM ‘O’ rings. Maximum working pressure 16.0 Bar. Maximum operating temperature 50°C.
Range of flow sensors with brass bodies. Maximum working pressure 16.0 bar. Maximum operating temperature 90°C
Thermostatic element with copper shell, polyethylene tube and PTFE gasket. Maximum working pressure 16.0 bar. Maximum operating temperature 100°C.
Range of threaded fittings with either plain brass, nickel plated brass or chrome plated brass bodies. Maximum operating pressure 16.0 bar. Maximum operating temperature 99°C.
Wallgate CWC Series 250 WC pan with direct acting flush valve and DFKIT03 air break (DC device). WC flushing mechanism has a solenoid valve controlling the flow, the valves are operated via an infrared sensor or a piezo control button, this mechanism is fitted with a DC pipe interrupter, the DFKIT03 is fitted with a flow regulator. Maximum working pressure 2.0 bar. Cold water use only.
Range of circulation valves and flow sensor valves with EPDM seals and O-rings. Maximum working pressure 10.0 bar. Maximum operating temperature 90ºC.
Range of pumps with either brass or stainless-steel bodies, stainless steel impellor and NBR ‘O’ rings. 20 & 33 brass series have a maximum working pressure of 16.0 bar. 33 stainless-steel series has a maximum working pressure of 20.0 bar. 22, 24 ,26, 38, 31, 32 & 34 series have a maximum working pressure of 20.0 bar. Cold water use only.
Shower handset (various finishes) with built in flow restrictor. Maximum operating temperature 60°C.
Range of shower handsets with a chrome plated body. Maximum operating temperature 60°C.
PVC lined, chrome plated shower hose. Maximum operating temperature 60°C.
Range of shower outlets with chromium plated bodies. Models P60901 and P61400 have check valves fitted at the inlets however, the complete products have not been fully tested to demonstrate they provide backflow prevention. Maximum operating temperature 70°C. Open outlet use only.
Wall mounted shower intake, having a brass body (chrome plated). The outlet incorporates a single check valve cartridge (however the complete assembly has not been tested to demonstrate it provides adequate backflow protection) Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.
Range of shower outlets incorporating brass bodies (various finishes). Maximum operating temperature 60°C.
Range of wall or ceiling mounted shower arms with brass bodies (various finishes). Maximum operating temperature 65°C.
Shower outlets, with NBR and EPDM ‘O’-rings and silicone nozzles. The shower handset has a plastic body with a chrome plated brass outer body and the overhead shower outlet and shower arm have chrome plated brass bodies The inlet of the shower handset incorporates an approved check valve cartridge, however, the complete product has not been fully tested to demonstrate it provides backflow protection. The inlet of the overhead shower consists of socket and ball joint. The inlets of both products incorporates a combined NBR gasket and stainless steel strainer. Maximum operating temperature 60°C.
Range of overhead shower heads and arms incorporating brass or ABS body. The inlet of models KSAB4K and HEAH06BK incorporates a stainless-steel strainer and plastic flow regulator. Maximum operating temperature 60°C.
Range of wall or ceiling mounted overhead shower outlets (chromium plated brass) and shower arm. Maximum operating temperature 60°C.
Range of shower outlets with chromium plated bodies with check valves fitted at the inlets however, the complete products have not been fully tested to demonstrate they provide backflow prevention. Maximum operating temperature 70°C. Open outlet use only.
In-line, Y-patterned strainer with stainless steel body and EPDM ‘O’-ring. Maximum working pressure 16.0 bar. Maximum operating temperature 100°C.
Range of in-line “Y” patterned strainers with brass bodies incoroporating NBR ‘O’-rings and stainless steel filters. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.
Range of inline strainers incorporating DZR brass bodies and a stainless steel mesh. Maximum working pressure 25.0 bar. Maximum operating temperature 85°C.
Range of flow switches with brass bodies incorporating EPDM ‘O’-rings, acting as a leak detection system that actuates an integral spherical valve to shut off the water supply. The inlet incorporates a stainless steel strainer. The outlet incorporates an approved check valve cartridge, however, the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum working pressure 16.0 bar. Maximum operating temperature 30°C.
Drain cock elbow incorporating a DZR brass body with EPDM ’O’-rings (ZELB250445 model) or NBR ‘O’-rings (ZELB250446 model added July 2022). Both models are for use with copper pipe (manufactured to BS EN 1057). Maximum working pressures: ZELB250445 model - 10.0 Bar. ZELB250446 - 16.0 bar. Maximum operating temperature 85°C.
Range of pillar taps (chrome plated brass) with non-rising spindle headworks and cross type operating members. The spout outlets incorporate a plastic flow straightener and the products are supplied with metal backnuts. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.
Range of pillar taps (chrome plated brass) incorporating non-rising spindle headwork with cross type operating members. The spout outlet incorporates a plastic flow straightener. The product is supplied with metal backnuts. Maximum working pressure 7.0 bar. Maximum operating temperature 60°C.
Range of pillar taps with brass bodies (chromium plated) incorporating quarter turn ceramic disc headwork with single lever operating members. The spout outlets incorporate a plastic aerator. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.
Range of stainless steel or ACB braided, PE-RT lined flexible hose assemblies, incorporating various end connections. The 15mm & 22mm compression models may incorporate an isolation valve. The 15mm pushfit incorporates an isolation valve. Models added April 2022 have a maximum operating pressure of 6.0 bar, a maximum operating temperature of 65°C and are for use with copper pipe manufactured to BS EN 1057. All other models have a maximum operating pressure of 10.0 bar and a maximum operating temperature of 85°C
‘Platinox SLP’ range of stainless steel braided silicone lined flexible hose assemblies with a variety of end connections (see size). Maximum working pressure 10.0 bar. Maximum operating temperature 70°C.
Range of vertical cased and insulated direct and indirect unvented stainless steel hot water storage cylinders. The storage cylinders incorporate an internal air bubble to accommodate the expansion of hot water. The DHW circuit has a factory fitted temperature and pressure relief valve set at 10.0@90˚C. The inlet control group includes a pressure reducing valve set at 3.0 bar, single check valve cartridge (verified by test and suitable for backflow protection against Fluid Category 2) and a expansion valve set at 8.0 bar. The products are supplied with a tundish and a motorised valve to be installed on the primary indirect circuit. Maximum supply pressure to the pressure reducing valve is 12.0 bar. Maximum working pressure of primary circuit is 6.0 bar. Maximum secondary circuit is 9.5 bar. Maximum operating temperature 85°C.
Range of 2, 3 and 4 port manifold assemblies with either DRZ brass or brushed chrome plated brass bodies incorporating screw down isolation valves with dome type operating members. Maximum working pressure 10.0 Bar Maximum operating temperature 85.0°C
Range of wall mounted, concealed, manual blending valves (chromium plated brass) incorporating a ceramic cartridge headwork, with a single lever operating member, controlling both flow and temperature. Model 36011660 is supplied with a shower hose and handset. The outlets incorporate an approved check valve cartridge however the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.
Range of deck mounted, manually operated blending valves with brass bodies (various finishes), incorporating ceramic cartridge headworks with either single lever (6900XX/METAL only) or dome type (all other models). The product is supplied with a shower hose and handset. Maximum working pressure 3.0 bar. Maximum operating temperature 60°C.
Range of wall mounted concealed shower valves (chromium plated brass) incorporating a ceramic cartridge headwork with single lever operating member. The shower outlet incorporates an approved single check valve cartridge however, the complete assembly has not been fully tested to demonstrate that it provides adequate backflow protection. Products are supplied with overhead shower outlet and shower hose. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.
Wall mounted bar type thermostatic shower valve (chromium plated brass) incorporating quarter turn ceramic disc headwork controlling the flow with dome type operating members. The temperature is controlled independently via a thermostatic cartridge with single lever type operating member and manual override button. Both inlets incorporate stainless steel strainers and an approved single check valve cartridge however, the complete product has not been fully tested to demonstrate it provides backflow protection. Supplied with shower hose and handset. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.
Wall mounted thermostatic mixing valves (chromium plated brass), flow is controlled via a quarter turn ceramic disc headwork with dome type operating members. The temperature is controlled by a thermostatic cartridge with dome type operating members which incorporate a manual override button. The inlets incorporate a stainless-steel strainer and an approved check valve cartridge; however, the complete products have not been fully tested to demonstrate that they provide backflow protection. Products are supplied with a shower hose, shower handset and riser rail. Maximum working pressure 5.0 bar. Maximum operating temperature 65°C.
Range of thermostatic mixing valves incorporating brass bodies (various finishes). Flow is controlled via a detent headworks and depending on model can be either a 2 or 3 headwork option supplying shower or bath outlets. The temperature is controlled independently via a thermostatic cartridge. Inlets incorporate a plastic strainer and a single check valve cartridge (however the complete unit has not been tested to demonstrate it provides adequate backflow protection). Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.
Range of ‘right hand’ or ‘left hand’ tempering valves having a plastic body incorporating a thermostatic element. The cold inlet incorporates a single check valve cartridge, however the complete product has not been fully tested to demonstrate it provides backflow protection Maximum working pressure 3.0 bar. Maximum operating temperature 60°C.
Range of wall mounted thermostatic mixers incorporating a brass body (chromium plated) and ceramic disc headwork with dome type operating members The temperature is controlled independently via a thermostatic cartridge with dome type operating member and manual override button. Both inlets incorporate a stainless steel strainers and an approved single check valve cartridge, however the complete product has not been fully tested to demonstrate it provides backflow protection. Model 1.1900.018 is supplied with a shower handset and riser rail. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.
Wall mounted, exposed, thermostatic bar type shower mixing valve (chromium plated brass) incorporating a quarter turn ceramic disc headwork with a dome type operating member, which controls the flow to a top mounted outlet. Temperature is controlled independently via a thermostatic cartridge with a dome type operating member incorporating a manual override button. Both inlets incorporate a combined NBR washer and stainless steel strainer and an approved single check valve cartridge, however the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C
Wall mounted thermostatic bar type shower valve incorporating a ceramic cartridge headwork, with single lever operating member, which controls and diverts the flow between the two shower outlets. The temperature is controlled independently via a thermostatic cartridge with a single lever operating member which incorporates a manual override button. Both inlets incorporate a stainless-steel strainer and an approved check valve cartridge, however, the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.
Range of wafer, lugged and flanged butterfly valves incorporating blue epoxy coated ductile iron bodies, EPDM seats and DI-FBE nylon coated stainless steel discs. Maximum working pressure 16.0 bar. Cold water uses only.
Range of ceramic disc diverter valve headworks with plastic bodies for use in specifically dimensioned bodies. Maximum working pressure 10.0 bar. Maximum operating temperature 85°C.
Range of equilibrium float operated valves with a stainless steel body and float (chrome plated), and a silicone seat. Maximum operating pressure 10.0 bar. Cold water use only.
Range of wall mounted flow control valves and trim kits (various finishes) with brass bodies incorporating a quarter turn ceramic disc headwork with various operating members (see model). The outlet of all models, except for the 38 882 xxx AXOR Uno model, incorporates a single check valve cartridge, (verified by test suitable for backflow protection against Fluid Category 2). Maximum working pressure 10.0 bar. Maximum operating temperature 70°C.
Range of spring loaded, resilient trim, non-return valves (blue epoxy coated cast iron body), with bronze bushing, stainlesss steel spring and disc, and EPDM seat. Maximum working pressure 16.0 bar. Maximum operating temperature 85°C.
Range of non return valves with bronze bodies and discs, and an EPDM washer. Maximum working pressure 20.0 bar. Maximum operating temperature 85°C.
Range of in-line adjustable pressure reducing valves, with DZR brass bodies and EPDM seat washers & ‘o’ rings and stainless-steel filters. Maximum inlet supply pressure 16.0 bar. Outlet pressure range: 0.8-6.0 bar. Maximum operating temperature 80°C.
Range of combined thermal balancing and pressure reducing valves with gun metal bodies, stainless-steel strainer, pressure gauge and temperature gauge. Maximum inlet supply pressure 16.0 bar. Outlet pressure range of 1.5 bar – 5.5 bar. Maximum operating temperature 85°C.
Range of latching solenoid valves with brass bodies and EPDM diaphragm Maximum working pressure 13.0 bar. Maximum operating temperature 55°C.
Solenoid valves with a plastic body and silicone diaphragm and ‘O’ rings. Maximum working pressure 8.0 bar. Cold water use only.
Spherical valve with brass body and ball, PTFE seat, EPDM and NBR ‘O’-rings. The valve incorporates a branch which is intended to connect to the primary circuit of a combination boiler. Maximum working pressure 10.0 Bar. Cold water use only.
Spherical valve incorporating a brass body and ball, PTFE seat, EPDM and NBR ‘O’-rings. Maximum working pressure 10.0 bar. Cold water use only.
Range of spherical valves incorporating DZR brass bodies and balls (nickel plated), EPDM ‘O’-rings, PTFE seats and red or blue coloured lever type operating members. Maximum working pressure 16.0 bar for compression models Maximum working pressure 40.0 bar for 1¼”-2” RP Female & pressfit models Maximum working pressure 50.0 bar ½”-1” RP Female & pressfit models. Maximum operating temperature 85°C.
Range of spherical valves incorporating brass bodies and balls (chrome plated), EPDM ‘O’-rings and PTFE seats. Model 124-3200 has a maximum working pressure 50.0 bar. Models 124- 3201 and 124-3202 have a maximum working pressure 40.0 bar. Model 124-3203 has a maximum working pressure 25.0 bar. Models 124-3204 and 124-3205 have a maximum working pressure 16.0 bar. Maximum operating temperature 100°C.
Range of PVC-U double union ball valves incorporating EPDM O-rings. Maximum working pressure 16.0 bar. (Cold water use only).
Range of screw down stop valves with plastic bodies to be used with PEX, MDPE and copper pipe. For above ground use only. Maximum working pressure 16.0 bar, cold water use only.
Front loading, commercial washing machine. Flow is supplied via solenoid valves and the unit incorporates a type `AB` airgap (verified by test - suitable for backflow protection against fluid category 5). Maximum working pressure 10.0 bar. Maximum operating temperature 70°C.
'Dicoat Medium Temp Black'. Factory applied, black coloured bitumen coating. Apply as per manufacturer's user instructions reference 'SPL/RD/UI/2019100121', issue no. '01' dated 08.07.2020. Cure for 7 days@30°C. Between 1st January 2021 to 22nd November 2021, the material is for use with water up to 50°C. Between 23rd November 2021 and 31st January 2026, the material is for use with water up to 60°C. This material is only approved for the curing conditions that appear on the approval. If the cure conditions are varied from those specified on the approval then the material is not covered by the scope of the approval.
'81661723' washers. Black coloured, resin impregnated carbon graphite washer components manufactured by isotactic pressing, sintering and grinding. For use with water up to 85°C.
'RS-0004'. White coloured, compression moulded seal ring manufactured from 'ADR 96' ceramic material. For use with water up to 85°C.
`Suns-02`. Grey coloured, factory applied cement mortar. Mix, apply and cure as per user instructions 'doc: SUNS-U110320, version B` dated 2015-12. Cure for 24 hours@25°C. Between 1st May 2021 and 30th March 2022, the cement mortar is suitable for use with water up to 23°C. Between 31st March 2022 and 31st May 2026, the cement mortar is suitable for use with water up to 60°C
'BSS-P'. Factory applied, blue coloured epoxy powder coating. Apply as per manufacturer's user instruction's 'BSS-D0001' dated '2020-12-10'. Cure for 7 minutes@180°C. For use with water up to 65°C. This material is only approved for the curing conditions that appear on the approval. If the cure conditions are varied from those specified on the approval then the material is not covered by the scope of the approval.
'XH-S'. Factory applied, grey coloured sulphate resistant Portland cement. Mix sand, cement and water in a 1.5:1.0:0.5 weight ratio. Cure for 3 hours@23-25°C. For use with water up to 65°C. This material is only approved for the curing conditions that appear on the approval. If the cure conditions are varied from those specified on the approval then the material is not covered by the scope of the approval.
'V-PET#1600 GRAY AG'. Factory applied, grey coloured epoxy powder paint. Apply as per manufacturer's instructions ref '20210201-1' dated 2021/2/1. Cure for 10 minutes@200°C. For use with water up to 60°C. This material is only approved for the curing conditions that appear on the approval. If the cure conditions are varied from those specified on the approval then the material is not covered by the scope of the approval.
'High Build Solvent Free Epoxy Coating Red'. Factory applied, red coloured epoxy coating. Apply as per manufacturer's user instructions reference 'SPL/RD/UI/202006119', issue no, '01' dated 20.08.2020. Cure for 24 hours@30°C. For use with water up to 50°C. This material is only approved for the curing conditions that appear on the approval. If the cure conditions are varied from those specified on the approval then the material is not covered by the scope of the approval.
'JIZJ-1'. Factory applied, light grey coloured Portland cement mortar. Mix cement, sand and water in a ratio of 1:1.7:0.55. Cure for 5 hours and 30 minutes@23°C. For use with water up to 65°C. This material is only approved for the mixing and curing conditions that appear on the approval. If the mix and/or cure conditions are varied from those specified on the approval then the material is not covered by the scope of the approval.
'HSXX CM-1'. Factory applied, grey coloured cement mortar. Mix, apply and cure as per manufacturer's Technical Data Sheet issue number '001' dated '2020.08.01'. For use with water up to 65°C.
'KOPATCH PC300-D/BLUE'. Factory applied, two component, dark blue coloured epoxy resin coating. Mix parts A & B in a volume ratio of 2:1. Cure for 7 days@20°C. For use with water up to 60°C. This material is only approved for the mixing and curing conditions that appear on the approval. If the mix and/or cure conditions are varied from those specified on the approval then the material is not covered by the scope of the approval.
'Ferolite NAM 30'. Green coloured fibre/NBR gasket material manufactured by calendaring. Shore hardness 42A. For use with water up to 65°C. For use only as a jointing/gasket material having been tested at a reduced surface area to volume ratio.
'Ferolite NAM 32'. Green coloured fibre/NBR gasket material manufactured by calendaring. Shore hardness 38A. For use with water up to 65°C. For use only as a jointing/gasket material having been tested at a reduced surface area to volume ratio.
'S-006'. Cream coloured, compression moulded GRP panel. For use with water up to 23°C.
‘Tecomid NA40 GR30 BK005 HS QW, Tecomid NA40 GR35 BK005 HS QW, Tecomid NA40 GR40 BK005 HS QW, Tecomid NA40 GR45 BK005 HS QW & Tecomid NA40 GR50 BK005 HS QW’. Black coloured, glass-fibre reinforced PA66 materials. For use with water up to 23°C.
'FYPBK-01 PE Pipes Black & Blue'. Extruded, HDPE pipes which are either black coloured (with blue, external stripe) or blue coloured. For use with water up to 65°C.
'FYFBK-01 PE Fittings Black & Blue'. Injection moulded, HDPE fittings which are either black coloured or blue coloured. For use with water up to 65°C.
‘Tecomid HT NT40 GR30 BK009 01 QW, Tecomid HT NT40 GR35 BK009 01 QW, Tecomid HT NT40 GR40 BK009 01 QW, Tecomid HT NT40 GR45 BK009 01 QW, Tecomid HT NT40 GR50 BK009 01 QW, Tecomid HT NT40 GR55 BK009 01 QW & Tecomid HT NT40 GR60 BK009 01 QW’. Black coloured, injection moulded glass-fibre reinforced PPA materials. For use with water up to 85°C.
'H600071'. Black coloured, compression moulded EPDM material. Shore hardness 55. Tested in-radius size 1.25mm. For use with water up to 65°C.
'51M6767'. Black coloured, injection moulded EPDM material. Shore hardness 67. Tested in-radius size 0.5mm. For use with water up to 60°C.
'TWK3628'. Black coloured, injection moulded EPDM material. Shore hardness 67. Tested in-radius size 0.5mm. For use with water up to 60°C.
'01/T60FKM, 01/T70FKM & 01/T80FKM 'O' rings and gaskets'. Green coloured, injection moulded FKM 'O' rings and gaskets. Shore hardness between 60 & 80. 'O' rings have a tested in-radii size of between 2.0mm & 3.5mm. Gaskets have a tested in-radii size of between 2.5mm & 3.5mm. For use with water up to 23°C.
‘ELASTOSIL® R plus 4303/60 mH (60), ELASTOSIL® R plus 4303/70 mH (70) and ELASTOSIL® R plus 4303/80 mH (80)’. Extruded, natural (appears white in colour) platinum cured HTV silicone rubber with a shore hardness of between 60 & 80. Tested in-radius size 2.0mm. The rubbers may also be coloured using the following ELASTOSIL® Color Pastes PT in a maximum of 1% content: PT Carbon black RAL 9005. PT Red brown RAL 3013. PT Red RAL 3000 F. PT Yellow RAL1016 PT Yellow RAL 1026 F PT Yellow RAL 1021. PT Grey RAL 7040. PT Dark blue 5010. PT Ultramarine blue RAL 5002. PT Violet RAL 4001. PT Green RAL 6017. PT Black RAL 9017. PT White RAL 9010. PT Yellow RAL 1033. PT Orange RAL 2004 F. PT Violet RAL 4002. PT Blue RAL 5022. PT Helio green RAL 6004. For use with water up to 85°C.
'THERMOLAST K TF5DWE'. Natural (appears white coloured), injection moulded TPE-S material. Shore hardness 55A. Tested in-radius size 1.0mm. For use with water up to 60°C. The natural material may be coloured using the following pigments present in their maximum permissible concentration: Blue 1, orange 2, yellow 3, red 1 & 2 and brown - for use with water up to 60°C. Black and white – for use with water up to 23°C.
Range of single hole, single outlet (fixed) electronically operated tap assemblies incorporating brass bodies (various finishes). Flow is controlled via solenoid valve and actuated by a touch sensor. The hose inlet incorporates a flow restrictor and the spout outlets incorporate a plastic aerator. Maximum working pressure 7.5 bar. Maximum operating temperature 60°C.
Bottom entry BS1212-4 (2016) compact type float operated valve for WC flushing cisterns. The inlet incorporates a flow restrictor. Maximum working pressure 10.0 bar. Cold water use only.
Bottom entry BS1212-4 (2016) compact type float operated valves for WC flushing cisterns. The inlet incorporates a strainer. Maximum working pressure 10.0 bar. Cold water use only.
BS EN 14055 (2018) WC Cistern incorporating a side or bottom entry float operated inlet valve discharging via a Type AG air gap and a dual flush Syphon of full flush volumes of up to 6 litres and a reduced flush of up to 4 litres. The cistern is operated by a lever. Maximum working pressure 10.0 bar. Cold water use only.
BS EN 14055 (2018) concealed WC cistern incorporating a side or bottom entry compact type float operated inlet valve discharging via a type AG airgap and a dual or single flush pneumatic or dual flush cable operated drop valve capable of full flush volumes of up to 6 litres with a reduced flush of up to 4 litres. The cistern is operated by manual push button/push plate. The side entry inlet valve is mounted internally and is supplied via a stainless steel braided EPDM lined flexible hose assembly which incorporates a servicing valve. Maximum working pressure 10.0 bar. Cold water use only.
BS EN 14055 (2018) WC Cistern incorporating a side or bottom entry float operated inlet valve discharging via a Type AG air gap and a dual flush Syphon of full flush volumes of up to 6 litres and a reduced flush of up to 4 litres. The cistern is operated by a lever. Maximum working pressure 10.0 bar. Cold water use only.
Concealed WC dual flushing cistern with a vertical BS 1212-4 (2016) float operated inlet valve providing a Type AG air gap arrangement and a pneumatically operated dual flush outlet valve. The flush volume is operated by a two push button assembly for a 6 or 3 litre flush volume. The inlet supply incorporates a servicing valve. For use with cold water only. Maximum working pressure 10.0 bar.
Concealed WC dual flushing cistern with a vertical BS 1212-4 (2016) float operated inlet valve providing a Type AG air gap arrangement and a pneumatically operated dual flush outlet valve. The flush volume is operated by a two push button assembly for a 6 or 3 litre flush volume. The inlet supply incorporates a servicing valve. Maximum working pressure 10.0 bar. Cold water use only.
BS EN 14055 (2018) concealed WC cistern incorporating a side entry compact type float operated inlet valve discharging via a type `AB` airgap (verified by test - suitable for backflow protection against fluid category 5) and a dual or single flush pneumatic or dual flush cable operated drop valve capable of full flush volumes of up to 6 litres with a reduced flush of up to 4 litres. The cistern is operated by manual push button/push plate. One of the side entry inlet valves is mounted internally and is supplied via a stainless steel braided EPDM lined flexible hose assembly which incorporates a servicing valve. Maximum working pressure 10.0 bar. Cold water use only.
BS EN 997:2018 Roca Wall Hung W.C. pan (Ceramic), Thomas Dudley ‘A’ frame incorporating a Thomas Dudley Vantage Concealed cistern. The cistern incorporates a side entry compact type float operated inlet valve providing a Type AG air gap with a dual or single flush pneumatic drop valve capable of full flush volumes of up to 6 litres and a reduced flush of up to 4 litres. The cistern can be operated by a manual push button / push plate options. The inlet valve is mounted internally and supplied via a stainless steel braided EPDM lined flexible hose assembly which incorporates a servicing valve. Maximum working pressure 10.0 bar. Cold water use only.
BS EN 997:2018 Vitra wall hung W.C. pan (Ceramic), Thomas Dudley ‘A’ frame incorporating a Thomas Dudley Vantage Concealed cistern. The cistern incorporates a side entry compact type float operated inlet valve providing a Type AG air gap with a dual or single flush pneumatic drop valve capable of full flush volumes of up to 6 litres and a reduced flush of 3 litres. The cistern can be operated by manual a push button / push plate options. The inlet valve is mounted internally and supplied via a stainless steel braided EPDM lined flexible hose assembly which incorporates a servicing valve Maximum working pressure 10.0 bar. Cold water use only.
BS EN 997:2018 Vitra wall hung W.C. pan (Ceramic), Thomas Dudley ‘A’ or Illusion Compact Universal frame incorporating a Thomas Dudley Vantage Concealed cistern. The cistern incorporates a side entry compact type float operated inlet valve providing a Type AG air gap with a dual or single flush pneumatic drop valve capable of full flush volumes of up to 6 litres and a reduced flush of 3 litres. The cistern can be operated by manual a push button / push plate options. The inlet valve is mounted internally and supplied via a stainless steel braided EPDM lined flexible hose assembly which incorporates a servicing valve. Maximum working pressure 10.0 bar. Cold water use only.
Range of three hole, deck mounted, single outlet (fixed) combination bidet tap assemblies (chromium plated brass), incorporating quarter turn ceramic disc headworks with single lever or cross top operating members. The spout outlet incorporates a plastic aerator. Product is supplied with pop up waste & metal backnuts. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.
Range of quarter turn ceramic disc headworks incorporating brass bodies and NBR ‘O’-rings. Housed in a brass body. Maximum working pressure 3.5 bar. Maximum operating pressure 60°C.
Range of single hole, single outlet (swivel) combination tap assemblies (brass bodies - various finishes - see model), incorporating a ceramic cartridge headwork with a single lever operating member. The product incorporates a pull-out spout outlet with a plastic aerator and an approved check valve cartridge, however, the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum working pressure 8.0 bar. Maximum operating temperature 60°C.
Range of single hole, single outlet (swivel) combination tap assemblies (various finishes) with ceramic cartridge headworks and single lever operating members. The spout outlet incorporates a pull-out spray with plastic aerator. The cold Inlet incorporates approved check valve cartridge, however, the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum operating pressure 5.0 bar. Maximum operating temperature 60°C.
Single-hole, single outlet, (fixed) combination tap assembly with brass bodies (chrome plated), incorporating non-rising spindle headworks with cross top operating members. The spout incorporates a plastic flow straighter this product is also supplied with an additional aerator. Model CL4 is supplied with a pop-up waste. Maximum working pressure 10.0 bar. Maximum working temperature 60°C.
Range of single hole, single outlet (fixed) combination tap assemblies (chromium plated brass). Incorporating a ceramic cartridge headworks, and single lever operating member. The spout outlet incorporates a plastic aerator. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.
Range of wall mounted, single hole, single outlet (fixed) combination tap assemblies with chromium plated, DZR brass bodies. The products incorporate a single sequential headwork with a single lever operating member or a push button. The spout outlets incorporate a plastic flow straightener. The inlets incorporate an approved check valve cartridge however, the complete products have not been fully tested to demonstrate it provides backflow protection. Products are supplied with metal back nuts. Maximum working pressure 8.0 bar. Maximum operating temperature 60°C.
Range of single hole, single outlet (fixed) combination tap assemblies incorporating chromium plated or stainless steel plated brass bodies, ceramic cartridge headwork with a single lever operating member. The spout outlets incorporate a plastic aerator. Some models are supplied with a click type waste (fully tested). Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.
Range of single hole, single outlet (fixed) combination tap assemblies (chromium plated brass bodies), incorporating ceramic cartridge headworks with single lever operating members incorporates plastic aerators supplied with a pop-up waste. Maximum working Pressure 10.0 bar. Maximum operating temperature 65ºC.
Range of single hole, single outlet (fixed) combination tap assemblies (chromium plated brass), incorporating a ceramic cartridge headwork with single lever operating members. The spout outlet incorporates a plastic aerator. The product is supplied with a click type waste. Maximum working pressure 5.0 bar. Maximum operating temperature 70°C.
Range of single hole, single outlet (fixed) combination tap assemblies (chromium plated brass), incorporating a ceramic cartridge headwork with a single lever operating member. The spout outlet incorporates a plastic aerator. Maximum working pressure 8.0 bar. Maximum operating temperature 60°C.
Range of single hole, single outlet (swivel) combination tap assemblies (chrome plated brass), incorporating a two quarter turn ceramic disk headworks and cross top operating members. The spout outlet incorporates a flow straightener. Supplied with single check valves (suitable for backflow protection against Fluid Category 2) with integral servicing valve for both inlets. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.
Range of single hole, single outlet (swivel) combination tap assemblies (chrome plated or brushed nickel coated brass), incorporating two quarter turn ceramic disk headworks and lever operating members. The spout outlet incorporates a plastic aerator. Supplied with single check valves (suitable for backflow protection against Fluid Category 2) with integral servicing valve for both inlets. Maximum working pressure 5.0 bar. Maximum operating temperature 65°C.
Range of single hole, single outlet (swivel) combination tap assemblies (various finishes) incorporating a ceramic cartridge headwork controlling the hot and cold flow. The 63264 model also incorporates a push to open, push to close, ‘detent’ headwork intended to control a filtered water supply. The spout outlets incorporate a plastic aerator. The cold water inlet hose is supplied with a chrome plated brass adaptor (½” BSP (F) x ½” BSP (M)) incorporating a check valve cartridge verified by test (suitable for backflow protection against Fluid Category 2). The 63264 model is also supplied with brass tee piece (½” BSP (F) x ½” BSP (M) x spigot (for quick connector)) for connection prior to the brass adaptor containing the check valve cartridge. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.
Range of single hole single outlet (swivel) combination tap assmeblies with quarter turn ceramic disc headworks and single lever operating members. The outlet incorporates a plastic aerator. Maximum working pressure 5.5 bar. Maximum operating temperature 60°C.
Range of single hole, single outlet (swivel) combination tap assemblies with (chromium plated) brass bodies, incorporating quarter turn ceramic disc headworks or ceramic cartridge headworks (see models) with single lever operating members. The swivel spout of the TMO35SSCM model is (chromium plated) stainless steel. The spout outlets incorporate a plastic aerator. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.
Two hole, single outlet (fixed) combination tap assembly (chrome plated brass) incorporating two quarter turn ceramic disc headwork with single lever operating members. The spout outlet incorporates a plastic flow straightener and the product is supplied with metal back nuts. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.
Two hole, single outlet (fixed) combination tap assembly (chrome plated brass) incorporating a single sequential headwork which controls flow and temperature with a single lever operating member. Both inlets incorporate eccentric isolation valves, flow restrictors and single check valve cartridges, however the complete product has not been fully tested to demonstrate it provides backflow protection. The spout outlet incorporates a plastic aerator and the product is supplied with metal back nuts. Maximum working pressure 10.0 bar. Maximum operating temperature 65°C.
Wall mounted two hole, single outlet (fixed) combination tap assembly (chrome plated brass) incorporating a single sequential headwork which controls flow and temperature with a single lever operating member. Both inlets incorporate eccentric isolation valves, flow restrictors and single check valve cartridges, however the complete product has not been fully tested to demonstrate it provides backflow protection. The spout outlet incorporates a plastic aerator and the product is supplied with metal back nuts. Maximum working pressure 10.0 bar. Maximum operating temperature 65°C.
Deck mounted two hole, single outlet (fixed) combination tap assembly (chromium plated brass) incorporating ceramic cartridge headworks with single lever operating members. The spout outlet incorporates a plastic aerator. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.
Range of wall mounted, two hole, single outlet (fixed) combination tap assemblies (various finishes) incorporating a ceramic cartridge headwork with single lever operating member. The spout outlets incorporates a plastic aerator. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.
Range of two hole, single outlet, (fixed) combination tap assemblies (chromium plated brass), incorporating a quarter turn ceramic disc headwork with single lever operating members. The spout outlets incorporate a plastic flow straightener and the products are supplied with metal backnuts. Maximum working pressure 10.0 bar. Maximum operating temperature 85°C.
Range of two hole, single outlet, (fixed) combination tap assemblies (chromium plated brass), Models M33136 & M1006 incorporate a quarter turn ceramic disc headwork with single lever operating members. Models M4306, M4306E & M4306F incorporate a non rising spindle headwork with dome type operating members. Model M4306G incorporate a non rising spindle headwork with cross top operating members. The spout outlets incorporate a plastic flow straightener and the products are supplied with metal backnuts. . Maximum working pressure 10.0 bar. Maximum operating temperature 85°C.
Two hole, double outlet swivel combination tap assembly (chrome plated brass), incorporating two quarter turn ceramic disc headworks with lever operating members. The product is supplied with metal backnuts. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.
Two hole, double outlet swivel combination tap assembly (chrome plated brass), incorporating quarter turn ceramic disc headworks with lever operating members. The product is supplied with metal backnuts. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.
Wall mounted, two hole, double outlet swivel combination tap assembly (chrome plated brass), incorporating quarter turn ceramic disc headworks with lever operating members.. The product is supplied with metal backnuts. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.
Three hole, single outlet (swivel) combination tap assembly with brass body (various finishes) incorporating quarter turn ceramic disc headwork with single lever operating members. The spout outlet incorporates a plastic aerator. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.
Range on inline filter cartridges incorporating plastic bodies. The filter media varies between models and includes active carbon, silver impregnated active carbon, silver carbon block & weak/strong cationic resin. Maximum working pressure 6.0 bar. Cold water use only.
Uponor S-Press (black and grey) composite fittings, Uponor S-Press composite PPSU reducers with S-Press PLUS composite PPSU nipples, Uponor RS fittings & Uponor S Press Metal Press fittings for use with for use with Uponor MLC pipe. Maximum working pressure and operating temperature: 10.0 bar@70°C Maximum working pressure and operating temperature: 16.0 bar @ Cold water use only.
Range of Eco Duo copper press fittings with EPDM ‘O’-rings for use with Eco-Duo copper tube. The joints are achieved by means of a crimping tool. For above ground use only. Maximum working pressure 16.0 bar. Maximum operating temperature 85°C.
Aquaflow polypropylene bodied compression fittings with EPDM ‘O’-rings for use with Elysee PE80 blue pipes. The fittings are supplied with a pipe liner. Above and below ground use. Maximum working pressure 12.5 bar. Cold water use only.
Range of polypropylene push-fit fittings and inserts for use with MDPE pipe (manufactured to BS EN 12201). For above and below ground use. Maximum working pressure 16.0 bar. Cold water use only.
Range of polypropylene push-fit fittings with inserts for use with MDPE Pipe (manufactured to BS EN 12201-2) on one side of the fitting and PB (BS 7291), PEX (BS 7291) or Copper (BS EN 1057) on the other. Models UTS147-DB, UTS197-DB & UTS251-DB are for above and below ground use. All other models are for above ground use only. Maximum working pressure when using 20mm pipe is 16.0 bar. Maximum working pressure when using 25mm & 32mm pipe is 12.5 bar. Cold water use only.
Range of brass press fittings with EPDM ‘O’-rings for use with EN ISO 21003 pipe. Maximum working pressure 10.0 bar. For cold water use only.
Shower waste water heat recovery unit, consisting of a PVC-U waste pipe with an internal copper tube which provides a double wall separation between the waste water and cold mains supply. Maximum working pressure 10.0 bar. Maximum operating temperature 30°C.
Electronically controlled heat interface units (HIU) with twin stainless-steel plate heat exchangers providing space heating and instantaneous hot water. The cold inlet supply to the plate heat exchanger incorporates an isolation valve and a water hammer arrestor. The space heating circuit incorporates an expansion vessel and a pressure relief valve (set at 3.0 bar). The product is supplied with a filling loop assembly consisting of an elbow shaped copper pipe, isolation valve and double check valve assembly (suitable for backflow protection against fluid category 3) which incorporates an isolation valve. The cold mains inlet and the domestic hot water outlet each incorporate a brass bodied spherical valve with a butterfly handle. Maximum working pressures and operating temperatures: Primary: 16.0 bar and 90˚C. Domestic hot water (DHW): 10 bar and 65˚C. Secondary (space heating): 2.5 bar and 85˚C.
Range of ice making machines which incorporate a solenoid valve to control the flow. Maximum working pressure 5.0 bar. Cold water use only.
Range of commercial ice making machines which incorporate a solenoid valve controlling the flow. Maximum working pressure 7.8 bar. Cold water use only.
Range of rotating piston, volumetric in-line water meters with brass bodies. Maximum working pressure 16.0 bar. Cold water use only.
Water meter incorporating a brass inner body, a plastic outer body and liquid silicone ‘O’-rings. Maximum working pressure 16.0 bar. Maximum operating temperature 50°C.
Range of pressure transmitters with stainless steel bodies. Maximum working pressures: DST-P140 model 25.0 bar, all other models 50.0 bar. Maximum operating temperature 90°C.
Keraflo range of a servo ceramic valves with DZR brass body. Maximum working pressure 6.0 bar. Cold water use only.
Wall mounted outlet with detachable shower hose connector (42037UK model) and wall mounted shower outlet (42018UK model). The 42018UK model is supplied with an optional, detachable shower hose connector assembly which incorporates an integral plastic flow regulator and an approved check valve cartridge however, the complete product has not been fully tested to demonstrate it provides backflow protection. Model 42037UK has a maximum operating temperature of 80°C. Model 42018UK has a maximum operating temperature of 60°C.
Wall bracket with a brass body (chrome plated) and EPMD ‘O’-rings. Maximum operating temperature 85°C.
Range of booster sets with a stainless steel manifold system connecting 2 or 3 wholesome water pumps (For 2HELIX & 3HELIX models only). The set also includes spherical valves, and a non-return valve Maximum working pressure: 10.0 Bar Maximum operating temperature: 40°C
Range of single stage centrifugal pumps with bronze housings or plastic housings (see model) and plastic impellers. Maximum working pressure 6.0 bar (UP(S)(O) 15-XX CES87 130 model only), 10.0 bar (all other models). Maximum operating temperature 95°C.
MBC 12-22WM & MBC 12-28WM models are wall mounted mains supply booster sets. They are supplied with two spherical isolation valves, a spherical bypass valve and two single check valve assemblies (suitable for backflow protection against Fluid Category 2). The check valve assemblies are to be installed in accordance with the manufacturers instructions, one upstream of the pump inlet and one after the bypass valve. The booster pump incorporates a plastic strainer on the inlet and a plastic flow regulator on the outlet and is housed within a wall mounted cabinet. MJ3 VM & MJ3 HM models are mains supply booster sets intended to be mounted on an expansion vessel (not supplied as part of the approval). They comprise of a pump, a suction and discharge manifold with bypass arrangement, and a spherical bypass valve which incorporates an approved check valve cartridge, however, the complete product has not been fully tested to demonstrate it provides backflow protection. The booster pump incorporates a plastic strainer on the inlet and a plastic flow regulator on the outlet. Maximum working pressure 6.0 bar. Cold water use only.
Range of shower handsets and shower heads with chrome plated bodies and built in flow restrictors. Maximum operating temperature 60°C.
Range of wall mounted handshower, hose and elbow sets with metal bodies (various finishes), incorporating an approved check valve cartridge, however, the complete product has not been fully tested to demonstrate it provides backflow protection. Handsets incorporate an approved check valve cartridge , however, the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum operating temperature 60°C
Range of shower kits incorporating a chrome plated plastic shower handset, shower hose and riser rail. Maximum operating temperature 65°C.
Range of shower handsets and overhead showers with metal chromium plated bodies with. Models 20123 and 15185 are fitted with check valves at the inlets however, the complete products have not been fully tested to demonstrate they provide backflow prevention. Model 20127 is supplied with a flexable hose connection. Maximum operating temperature 60°C.
Shower kit consisting of a shower hose, handset and raiser rail (EKIT01/A model) or shower handset only (AIR1HSCPWHUK model). Maximum operating temperature 60°C.
Range of hand held shower outlets incorporating plastic bodies and over head showeroutlets incorporating brass bodies. Model 46127 includes a handset and hose with a single check valve fitted at the inlet and outlet to the shower hose (however the complete assembly has not been tested to demonstrate it provides adequate backflow protection). model 46154 includes a single check valve in the shower handset (however the complete assembly has not been tested to demonstrate it provides adequate backflow protection). Over head shower (model 46150) outlets have an adjustable elbow connection. Maximum operating temperature 60°C.
Range of shower outlets incorporating brass bodies (various finishes) and EPDM ‘O’-rings. Maximum operating temperature 65°C.
Range of shower arms and brackets with brass bodies (various finishes). Shower brackets incorporate single check valves cartridge, however the complete assembly has not been tested to demonstrate it provides adequate backflow protection. Maximum operating temperature 85°C.
Range of shower handsets with chromium plated plastic bodies. Maximum operating temperature 75°C.
Range of wall mounted hose union taps (brass, chrome plated brass or DZR brass body) incorporating a non-rising spindle headwork with a butterfly handle operating member. Maximum working pressure 16.0 bar. Maximum operating temperature 85°C.
Range of pillar taps (chrome plated brass) with quarter turn ceramic disc headwork and single lever operating members. The spout outlet incorporates a plastic flow straightener. The product is supplied with metal backnuts. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.
Bath pillar taps (chrome plated brass) with ¼ turn ceramic disc headworks with single lever operating members. The product is supplied with metal backnuts. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.
Range of pillar taps incorporating brass bodies (chrome plated), non-rising spindle headworks (models 922031 & 922033) or quarter turn ceramic disc headowks (all other models). The spout outlet incorporates a flow straightner. Maximum working pressure 6.0 bar. Maximum operating temperature 60°C.
Range of pillar taps incorporating brass bodies (chrome plated), non-rising spindle headworks (model 922038) or quarter turn ceramic disc headowks (model 922068). The spout outlet incorporates an flow straightener Maximum working pressure 6.0 bar. Maximum operating temperature 60°C.
Self-closing basin tap assembly (chromium plated brass) incorporating spring loaded headwork and dome type operating members. The inlet incorporates a plastic flow restrictor and the spout outlet incorporates a plastic flow straightener. The product is supplied with a metal backnut. Maximum working pressure 10.0 bar. Maximum operating temperature 70ºC.
Range of multi-layer shower hoses with a PVC inner hose, supplied with EPDM ‘O’-rings. Maximum operating temperature 60°C.
‘PANASIA 051 series’ of stainless steel braided EPDM lined flexible hose assemblies with brass or chrome plated brass end connections. Maximum working pressure and operating temperatures: 16.0 bar and cold water use only. 10.0 bar @ 85°C.
Range of stainless steel braided, EPDM lined flexible hose assemblies. Maximum working pressure 10.0 bar. Maximum operating temperature 90°C.
Range of EPDM braided hoses (various options) and optional end connections. Maximum working pressure 10.0 bar. Maximum operating temperature 85°C.
Range of stainless-steel braided EPDM lined flexible hose assemblies, incorporating EPDM ‘O’-rings. Maximum working pressure 10.0 bar. Maximum operating temperature 85°C.
Range of stainless steel and ACB braided hoses with and EPDM liner and various end connections. Maximum working pressure 10.0 bar. Maximum operating temperature 85ºC. Hoses with plastic push fittings: maximum working pressure 6.0 bar. Maximum operating temperature 65ºC.
Range of multi-layer shower hoses with a PVC inner hose, supplied with EPDM ‘O’-rings. Maximum operating temperature 60°C.
Range of “Tempest” Indirect and direct unvented storage cylinders consisting of factory fitted single or twin coil circuit with either a primary or solar coil. The secondary circuit is factory fitted with a temperature and pressure relief valve set at 7.0 bar@90˚C. The product is supplied with an inlet control group (safety kit) consisting of a pressure reducing valve adjustable between 2.7 and 3.3 bar, strainer, an expansion relief valve set at 6.0 bar and a check valve cartridge (verified by test - suitable for backflow protection against Fluid Category 2). A tundish and expansion vessel are also provided. Maximum supply pressure to the inlet control group 10.0 bar. Maximum working pressures: Secondary circuit 3.0 bar, Primary Circuit 3.0 bar & Solar circuit 5.5 bar. Maximum operating temperature 65°C.
Whitewolf Alpha ranges of Direct, Indirect, Solar Single, Solar Twin, Slim Direct and Slim Indirect stainless steel insulated unvented hot water storage cylinders with external expansion. The DHW circuit consists of a temperature and pressure relief valve set at 7.0 bar and 90°C, an inlet control group consisting of a pressure reducing valve adjustable between 2.7 and 3.3 bar, an expansion relief valve (SRV) set at 6.0 bar, a strainer and a check valve cartridge, verified by test (suitable for backflow protection against Fluid Category 2) also supplied with a tundish. Maximum supply pressure to the inlet control group 10.0 bar. Maximum working pressures - Primary circuit 6.0 bar, Secondary circuit 5.5 bar. Maximum operating temperature 65˚C.
502 series of automatic air venting valves with brass bodies, plastic float and EPDM ‘O’-rings. Maximum working pressure 10.0 bar. Maximum operating temperature 115°C. Model added September 2021 (501500) has a maximum operating temperature of 120°C. All other models have a maximum operating temperature of 115°C.
Automatic air venting valve with brass bodies, stainless steel float and EPDM ‘O’-rings. Maximum working pressure 16.0 bar. Maximum operating temperature 120°C.
Wall mounted manually operated, concealed blending valves (cast brass body) with a ceramic cartridge headwork controlling both flow and temperature with as single lever operating member and a manual diverter to shower outlets with a single lever operating member. Maximum operating pressure 5.0 bar. Maximum operating temperature 65°C.
Range of wall mounted, concealed, manual blending valves incorporating brass bodies and quarter turn ceramic disc headworks. Maximum working pressure 10.0 bar. Maximum operating temperature 90°C.
Range of wall mounted, concealed, manually operated blending valves with brass bodies (various finish trim kits - see model) incorporating a ceramic cartridge headwork with a single lever operating member. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.
Wall mounted, manually operated blending valve, (brass body with a chromium plated brass trim set), incorporating a ceramic cartridge headwork with a single lever operating member controlling temperature and flow, and a manual diverter controlling the flow to the shower hose and handset or a secondary shower outlet. The product is supplied with a shower hose and handset. The handshower outlet connection and the shower handset inlet both incorporate an approved check valve cartridge, however the complete assembly has not been fully tested to demonstrate that it provides backflow protection. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.
3 outlet concealed wall mounted thermostatic mixer valve incorporating a quarter turn ceramic disc headwork controlling the flow. The temperature is controlled independently via a thermostatic cartridge. Inlets incorporate stainless steel strainers and approved single check valve cartridges, however, the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum working pressure 5.0 bar. Maximum operating temperature 65.0°C
Range of concealed thermostatic mixing valves with brass bodies and exposed trim sets (various finishes). Incorporating a ceramic disc headwork controlling and diverting the flow between shower outlets and an independent thermostatic cartridge controlling the temperature. The inlet incorporates a single check valve cartridge (however the complete assembly has not been tested to demonstrate it provides adequate backflow protection). Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.
Range of wall mounted, concealed, thermostatic shower valves with brass bodies and various trim plates (see model). V-BOX Therm. 2 way Shower Mixers incorporate a 2-way ceramic disc diverters/headworks (2 on, 1 off) controlling the flow with a single lever operating member. V-BOX Therm. 1 way Shower Mixers incorporate a quarter turn ceramic disc headwork controlling the flow with a single lever operating member. The temperature is controlled independently via a thermostatic cartridge with a single lever operating member which incorporates a manual override button. Each inlet incorporates an approved check valve cartridge, however, the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.
Non-metallic materials and components comply with BS6920 at 60°C
Thermostatic mixing valve with a brass body within a plastic outer case. Flow is controlled via an electronically operated ceramic cartridge via a motor. Temperature is controlled via a temperature sensor that electronically adjusts the ceramic cartridge via a motor. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.
Range of wall mounted bar type thermostatic shower valves (chromium plated brass) incorporating a 2-way ceramic disc diverter headwork controlling the flow between an overhead shower outlet or a shower handset with dome or cube type operating members. The temperature is controlled independently via a thermostatic cartridge with dome or cube type operating member that also incorporates a manual override button. Both inlets incorporate stainless steel strainers and approved single check valve cartridges, however, the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.
Range of wall mounted concealed thermostatic shower valves with DZR brass (F4000/HF concealed part) or brass bodies. Flow is controlled by either a 3-way (2 on, 1 off) or 4-way (3 on, 1 off) ceramic disc shower to shower diverter headwork (see model) with a dome type operating member. The temperature is controlled independently via a thermostatic cartridge with a dome type operating member that also incorporates a manual override button. The inlets incorporate a single check valve cartridge, however, the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.
Wall mounted thermostatic shower valves with brass bodies (chromium plated) incorporating a ½ turn ceramic disc controlling the flow to the handshower. The temperature is controlled independently via a thermostatic cartridge with a dome type operating member incorporating a manual override button. Inlets incorporate stainless steel strainers and approved single check valve cartridges however, the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.
Range of wall mounted concealed thermostatic shower valves with DZR brass (CPHF4000HF concealed part) or brass bodies. Flow is controlled by either a 3-way (2 on, 1 off) or 4-way (3 on, 1 off) ceramic disc shower to shower diverter headwork (see model) with a dome type operating member. The temperature is controlled independently via a thermostatic cartridge with a dome type operating member that also incorporates a manual override button. The inlets incorporate a single check valve cartridge, however, the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.
Adjustable T-type thermostatic mixing valve (chromium plated brass). Each inlet incorporates a stainless-steel strainer and a single check valve cartridge, verified by test (suitable for backflow protection against Fluid Category 2). Maximum working pressure 5.0 bar. Maximum operating temperature 60ºC.
Range of wall mounted, thermostatic blending valves with brass bodies (various finishes), incorporating a quarter turn ceramic disc headwork controlling the flow with a single lever operating member. The temperature is controlled independently via a thermostatic cartridge with a single lever operating member which incorporates a manual override button. The inlets incorporate an approved check valve cartridge, however, the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.
Range of wall mounted thermostatic bar type mixing valves incorporating chrome plated brass bodies, ceramic disc headwork with dome type operating members controlling the flow. The temperature is independently controlled by a thermostatic cartridge with dome type operating member which incorporates a manual override button.The inlets incorporate stainless-steel strainers and an approved single check valve cartridges however, the complete product has not been fully tested to demonstrate it provides backflow protection. Product is supplied with a shower hose, shower handset and riser rail. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.
Wall mounted, concealed thermostatic shower valve incorporating quarter turn ceramic disc headwork with dome type operating members controlling the flow to multiple shower outlets. The temperature is controlled independently via a thermostatic cartridge with dome type operating member. The inlets incorporate an approved check valve cartridge however the complete product has not been fully tested to demonstrate it provides backflow protection Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.
Range of wall mounted thermostatic shower valves, riser rail, shower handset, shower hose and overhead shower outlet. The valve incorporates a brass body (various finishes) and ceramic disc headwork with dome type operating member which controls and diverts the flow between the two shower outlets. The temperature is controlled independently via a thermostatic cartridge with a dome type operating member incorporating a manual override button. Inlets incorporate stainless steel filters and a single check valve cartridge however the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum working pressure 8.0 bar. Maximum operating temperature 60°C.
Range of butterfly valves with a plastic body, PVDF disc & EPDM sealing ring. The closing mechanism is controlled by a single lever operating member. Maximum working pressure 16.0 Bar. Maximum operating temperature 80°C. Maximum working pressure: (DN200 - 250): 10.0 bar (DN300): - 6.0 bar
Range of handwheel operated butterfly valves with blue epoxy coated ductile iron bodies and discs, and EPDM seals. Maximum working pressure 10.0 or 16.0 bar (see model). Maximum operating temperature 65°C.
Range of butterfly valves incorporating epoxy coated cast iron bodies, zinc coated iron discs and EPDM seats. Maximum working pressure 16.0 bar. Maximum operating temperature 100°C.
Range of lug type butterfly valves incorporating blue epoxy coated cast iron bodies, EPDM seats and stainless steel discs. Maximum working pressure 16.0 bar. Maximum operating temperature 100°C.
Range of wafer type butterfly valves incorporating blue epoxy coated cast iron bodies, EPDM seats and stainless steel discs. Maximum working pressure 16.0 bar. Maximum operating temperature 100°C.
Range of wafer or lugged butterfly valves incorporating blue epoxy coated ductile iron bodies, EPDM seats and stainless steel or ductile iron discs (nickel plated). The products are supplied with either bare shaft or with lever or gear operating members. Maximum working pressure 16.0 bar. Maximum operating temperature 100°C.
Range of butterfly valves incorporating blue epoxy coated ductile iron bodies and discs, EPDM seats and EPDM ‘O’-rings. Maximum working pressure: 16.0 bar. Maximum operating temperature 60°C.
Range of butterfly valves with blue epoxy coated ductile iron bodies, ductile iron or stainless steel discs with EPDM seats and a lever operating member. Maximum working pressure 16.0 bar. Maximum operating temperature 80°C.
Range of butterfly valves incorporating blue epoxy coated ductile iron bodies and discs and an EPDM rubber seat. Maximum operating pressure 16.0 bar. Maximum operating temperature 80°C.
Range of butterfly valves incorporating blue epoxy coated ductile iron bodies, stainless-steel discs and EPDM seats. Maximum working pressure 16.0 bar. Maximum operating temperature 85ºC.
Range of combined pre-set temperature and pressure relief valves incorporating Bronze bodies, DZR brass seat and plunger, EPDM ‘O’-rings, PTFE seal and silicone diaphragm. The valves incorporate a manually operated lever easing gear. The valves are factory pre-set between 0.4 bar and 12.5 bar. Maximum operating temperature 90°C.
Concealed 2-way or 3-way ceramic disc diverter valve with shut off mechanism incorporating a brass body. Maximum working pressure 5.5 bar. Maximum operating temperature 60°C.
Range of float operated valves incorporating brass bodies and EPDM seats. Maximum working pressure 14.0 bar. Maximum operating temperature 85°C.
Range of pilot operated float control valves with blue epoxy coated ductile iron bodies, NBR ‘O’-rings and gaskets. The products have flow control facility controlled via a float operated pilot valve. Supplied with auxiliary components including stainless steel pipe, spherical valves, Y-pattern strainer and a needle valve. Maximum working pressure 8.0 bar. Cold water use only.
Range of concealed flow control valves with a brass body and trim set (various finishes). The product incorporates a ceramic disc headwork with a single lever operating member divertering the flow between 2 shower outlets or a bath spout outlet. The diverter has an off position as you change between each outlet. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.
Range of deck mounted flow control valves with brass bodies (chrome plated trim sets and various operating members - see models) incorporating quarter turn ceramic disc headworks. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.
Range of flow control valves incorporating brass bodies, quarter turn ceramic disc headworks and NBR ‘O’-rings. Maximum working pressure 5.5 bar. Maximum operating temperature 60°C.
Range of spring loaded, resilient trim, non-return valves (blue epoxy coated cast iron body), with bronze bushing, stainlesss steel spring and disc, and EPDM seat. Maximum working pressure 16.0 bar. Maximum operating temperature 85°C.
Wafer type spring loaded, resilient trim, non-return valve with stainless steel bodies, springs and guides, and an EPDM seat. Not suitable for backflow protection. Maximum working pressure 16.0 bar. Maximum operating temperature 100°C.
Range of non-return, swing gate valves with blue epoxy coated ductile iron bodies and EPDM rubber seals. Maximum working pressure 10.0 or 16.0 bar (see model). Maximum operating temperature 65°C.
Range of in-line adjustable pressure reducing valves with Nickel plated DZR brass bodies and EPDM gaskets. Maximum inlet supply pressure 16.0 bar. Outlet pressure in the range of 0.5 bar to 6.0 bar. Maximum operating temperature 80°C.
Range of in-line adjustable pressure reducing valves, with DZR brass bodies and EPDM seat washers & ‘o’ rings and stainless-steel filters. Various models supplied with pressure gauge (please see model list). Maximum inlet supply pressure 16.0 bar. Outlet pressure range: 0.8-6.0 bar. Maximum operating temperature 80°C.
Range of in-line, manually adjustable pressure reducing valves with blue epoxy coated ductile iron bodies and EPDM gaskets and ‘O’-rings (all models) and an EPDM diaphragm (VRCD-M models only). VRCD models: Outlet pressure range: 1.5 - 6.0 bar or 5.0 to 12.0 bar. VRCD-M models: Outlet pressure range: 1.5 - 6.0 bar. Maximum supply pressure 16.0 bar. Cold water use only.
Range of in-line adjustable pressure reducing valves, with DZR brass bodies and EPDM seat washers & ‘o’ rings and stainless-steel filters. Various models supplied with pressure gauge (please see model list). Maximum inlet supply pressure 16.0 bar. Outlet pressure range: 0.8-6.0 bar. Maximum operating temperature 80°C.
Range of in-line, manually adjustable pressure reducing valves with blue epoxy coated ductile iron bodies and EPDM gaskets and ‘O’-rings (all models) and an EPDM diaphragm (VRCD-M models only). VRCD models: Outlet pressure range: 1.5 - 6.0 bar or 5.0 to 12.0 bar. VRCD-M models: Outlet pressure range: 1.5 - 6.0 bar. Maximum supply pressure 16.0 bar. Cold water use only.
Range of normally closed solenoid valves with brass bodies, stainless steel spring, EPDM seal and diaphragm. Maximum working pressure - WZS1DF prefix models 7.84532 bar, WSLP1DF prefix models 9.80665 bar. Maximum operating temperature 85°C.
A range of normally closed servo-assisted diaphragm solenoid valves with brass bodies and EDPM diaphragms. Models 23C, 23D, 23E & 23F have a maximum working pressure of 16.0 bar. Models 23G, 23H & 23I have a maximum working pressure of 10.0 bar. Cold water use only
Range of normally closed solenoid valves with a plastic body and silicone rubber diaphragm & ‘O’-rings. Models ending ‘007’ have a maximum working pressure of 0.25 bar. All other models have a maximum working pressure of 0.06 bar. Maximum operating temperature 90°C.
Range of solenoid valves with plastic bodies and EPDM diaphragms. The inlet incorporates a plastic strainer and an integrated flow meter sensor. Both the inlet and the outlet incorporate a white plastic flow restrictor. The products are also supplied with an optional EPDM outlet gasket, for installation over the outlet spigot. Maximum working pressure 10.0 bar (to diaphragm). Maximum operating temperature 85°C.
Range of spherical valves with nickel plated DZR brass bodies with either red or blue, lever or butterfly operating member, brass ball and PTFE seat. Maximum working pressure 25.0 bar. Maximum operating temperature 100°C.
Range of spherical valves incorporating brass bodies (model Cim287RB5 nickel plated) brass balls (chrome plated), PTFE seats, EPDM ‘O’-rings and butterfly handle operating members. Maximum working pressure 16.0 bar. Maximum operating temperature 100°C.
Range of spherical valves incorporating brass bodies and balls (chrome plated), EPDM ‘O’-rings and PTFE gaskets. Products are supplied with either red or blue butteryfly operating member or screw driver operated. Maximum working pressure 50.0 bar. Maximum operating temperature 100°C.
Range of spherical valves incorporating chrome plated brass bodies and balls, and PTFE seats. The products are supplied with either butteryfly or lever handles. Maximum working pressures - see model. Maximum operating temperature 100°C.
Range of spherical valves with brass bodies, brass ball (chrome plated) and PTFE gaskets. Products are supplied with either blue or red lever or butterfly type operating members. Maximum working pressure 50.0 bar (½ models). Maximum working pressure 40.0 bar (¼”, ¾” and 1” models). Maximum working pressure 25.0 bar (1¼” models). Maximum working pressure 16.0 bar (1½” to 4” models). Maximum operating temperature 100°C. Models added March 2022: Maxmimum working pressure of 10.0 bar. Maxmimim operating temperature 60°C (models AI-360115 & 124-3001)
Range of gate valves incorporating bronze bodies, wedges and PTFE seals. The valves are operated via a non-rising spindle with a hand wheel operating member. For use with copper pipe manufactured to EN1057. Maximum working pressure 16.0 bar. Maximum operating temperature 100°C.
Range of gate valves incorporating cast iron bodies (blue epoxy coated), EPDM rubber coated wedges and non-rising spindles with hand wheel operating member. Maximum working pressure 10.0 bar (Z45X-10Q model). Maximum working pressure 16.0 bar (Z45X-16Q models). Maximum operating temperature 80°C.
Range of gate valves incorporating DZR brass bodies and wedges, non-rising spindles and handwheel operating members. Maximum working pressure 16.0 bar. Maximum operating temperature 85°C.
Range of gate valves incorporating ductile iron epoxy coted bodies and with EPDM ‘O’-ring seals and discs. The valves are operated via a non-rising spindle with a hand wheel operating member Maximum working pressure 16.0 bar. Maximum operating temperature 85°C.
Range of commercial conveyor type dishwashers with the flow controlled by a solenoid valve and discharged via three type AB air gaps (pre-wash, rinse and wash) (verified by test - suitable for backflow protection against fluid category 5). The products are supplied with a brass bodied ‘Y’-pattern strainer, brass adaptors ¾”x¾” (M)x(M) and (F)x(F) and dual layer PVC inlet hoes(s) (grey outer/black inner) and EPDM washers. The DR*11**** model has two solenoids and requires three inlet hoses and also includes a brass tee-piece to connect them ¾”x¾”x¾” (M). Maximum working pressure 6.0 bar. Maximum operating temperature 60ºC.
Range of ion generating water conditioners incorporating UPVC pipework and fittings, flow meter and stainless steel electrode pens contained within the electrode chamber. Maximum working pressure 9.0 bar. Cold water use only.
Range of ion exchange water softeners (salt regenerated) for domestic use. Maximum working pressure 6.0 bar. Cold water use only.
'H-3500-6351-9221'. Grey coloured silicon carbide washers manufactured by isotactic pressing, sintering and grinding. For use with water up to 85°C.
'SRC RZ S&M&BDN 20'. Factory applied, grey coloured sulphate resistant cement mortar. Mix cement and sand in a 1:2.2 mass ratio. Combine that mix and water in a 1:0.45 mass ratio. Cure for 24 hours@25°C and 95% relative humidity. For use with water up to 60°C. This material is only approved for the mixing and curing conditions that appear on the approval. If the mix and/or cure conditions are varied from those specified on the approval then the material is not covered by the scope of the approval.
'EP01'. Factory applied, blue coloured epoxy powder coating. Apply and cure as per manufacturer's instructions 'V6.3' issued March 2019. For use with water up to 65°C.
'V-PET #1600 Gray F'. Factory applied, grey coloured epoxy resin powder coating. Apply as per manufacturer`s instructions ref. no. '20210216-1' dated 2021/2/16. Cure for 10 minutes@200°C. For use with water up to 60°C. This material is only approved for the mixing & curing conditions that appear on the approval. If the mix and/or cure conditions are varied from those specified on the approval then the material is not covered by the scope of the approval.
‘Promag’. Factory applied coating system, black coloured, consisting of two component primer and three component polyurethane top coat. Mix primer in a ratio 2:1 by weight (component A:B), apply and cure for 2 hours at 23°C, then mix topcoat in a ratio 100:5.6:2.4 by weight (component A:B:C) before applying and curing for 20 seconds at 23°C. This approval covers the following manufacturing sites: France and China. For use with water up to 23°C.
'EP-621'. Factory applied, blue coloured epoxy powder coating. Apply and cure as per manufacturer's instructions file no: 'TJR-QM-CO-032', 'edition A1' dated '2021-Feb.-26th'. For use with water up to 65°C.
'HEMPADUR 35600 Cream and Red'. Factory applied, cream or red coloured (when mixed), two-component epoxy coatings consisting of a base and curing agent. Mix the base and curing agent in a 14.8:5.2 volume ratio. Cure for 8 days@25°C. For use with water up to 60°C. This material is only approved for the mixing and curing conditions that appear on the approval. If the mix and/or cure conditions are varied from those specified on the approval then the material is not covered by the scope of the approval.
'Balinit DLC-Star.' Factory applied, grey coloured CrN + a-C:H coating. Apply as per manufacturer's instructions reference 'VS200295' dated 18.03.2021. Cure for 6 hours@200°C. For use with water up to 85°C. This material is only approved for the curing conditions that appear on the approval. If the cure conditions are varied from those specified on the approval then the material is not covered by the scope of the approval.
`BFSC MAS S&MDN 20`. Factory applied, grey coloured, blast furnace slag cement mortar. Mix sand and cement in a mass ratio of 2.35:1. Add water to give a mass ratio of 1:0.45 (cement:water). Cure first time for 7 hours@70°C. Cure second time for 12 hours@70°C. For use with water up to 60°C. This material is only approved for the mixing and curing conditions that appear on the approval. If the mix and/or cure conditions are varied from those specified on the approval then the material is not covered by the scope of the approval.
'Flogul® 645 Bleu 5005 (blue coloured) & Flogul® 645 Noir (black coloured)'. Factory applied, PVDC coatings to be applied in accordance with manufacturer's data sheet dated '11/09/2018'. Cure for 7 days@20°C. Flogul® 645 Bleu 5005 is for use with water up to 23°C. Flogul® 645 Noir is for use with water up to 60°C. These materials are only approved for the curing conditions that appear on the approval. If the cure conditions are varied from those specified on the approval then the materials are not covered by the scope of the approval.
'RUNBAO Epoxy resin coating 5017' (light blue), 'RUNBAO Epoxy resin coating 5005' (blue) & 'RUNBAO Epoxy resin coating 3016' (red). Factory applied electro-statically sprayed epoxy resin coating. Apply and cure as per manufacturer's instructions version 'YZRB-2015V1.0' dated '2015-06-01'. Between January 2021 and 9th December 2021, the materials were suitable for use with water up to 23°C. Between 10th December 2021 and 31st January 2026, the materials are suitable for use with water up to 85°C.
'YHCM-01'. Factory applied, grey coloured sulphate resisting cementitious mortar. Mix sand, cement & water in a ratio of 1: 2.5: 0.3. Cure for 4 hours@20°C. For use with water up to 60°C. This material is only approved for the mixing and curing conditions that appear on the approval. If the mix and/or cure conditions are varied from those specified on the approval then the material is not covered by the scope of the approval.
'OCPOL 611'. Beige coloured (translucent), Isophthalic Unsaturated Polyester Resin with glass fibre material manufactured using hand-lay method. For use with water up to 70°C.
'ResinTech CG10-F-UPS'. Gold coloured ion exchange resin. For use with water up to 65°C.
'Krytox™ Oils; GPL 104, 143AB, VPF 1525, VPF 1531, AUT 1045, GPL 105, GPL 106, 143AC, 143AD & GPL 107'. Clear (colourless), perfluoropolyether oils. 'Krytox™ Greases; GPL 204, 240AB, AUT 2045, GPL 205, GPL 206, 240AC, 240AD & GPL 207'. White coloured, Polytetrafluoroethylene thickened perfluoropolyether greases. All are suitable for use with water up to 85°C.
'RP380s & RP361'. Off-white coloured (opaque) silicone greases. Apply as per manufacturer's instructions. For use with water up to 65°C.
'Badamid B70 GF40 UV WL Black'. Black coloured, injection moulded, glass filled PA6 material. For use with water up to 65°C.
'PA66+50%GF 1620G50 BK015'. Black coloured, injection moulded PA66 (with 50% glass fibre) material. For use with water up to 85°C.
Grivory GV-2H natural & GV-2H black 9915. GV-2 FWA natural & GV-2 FWA black 9225. GV-4H natural & GV-4H black 9915. GV-4 FWA natural & GV-4 FWA black 9225. GV-5H natural & GV-5H black 9915. GV-5 FWA natural, GV-5 FWA black 9225 & Grivory XE 4275 black 9225. GV-6H natural & GV-6H black 9915. GV-6 FWA natural & GV-6 FWA black 9225. Injection moulded, natural (appears white) or black coloured, glass reinforced nylon materials. For use with water up to 23°C.
‘ELGEF PE-100 electrofusion fittings’, Black coloured, injection moulded polyethylene electrofusion fittings. For use with water up to 65°C.
'MMP PE100 Pipe'. Black coloured (with blue coloured external stripes), extruded PE100 pipes manufactured from 'Sabic P6006' or 'Borouge HE3490-LS'. For use with water up to 85°C.
'Popular HDPE Pipe'. Black coloured (blue external stripes), extruded HDPE pipe. For use with water up to 60°C.
'3301 black (330160415BLK)'. '3301 black (330130415BLK)' was added to the approval in November 2023. Black coloured, single sided polyethylene foam tapes with acrylic adhesive system. For use with water up to 23°C.
‘Union Pipes Industry – K.S.A. HDPE Pipe’, manufactured from ‘P6006’ by Union Pipes Industry Co. Ltd, Rabigh, Saudi Arabia. Black coloured, extruded HDPE pipe. For use with water up to 60°C.
'BORFIT HDPE fittings'. Black coloured, injection moulded HDPE fittings. For use with water up to 60°C.
'HE3490-ELS-H'. Black coloured, extruded polyethylene material. For use with water up to 60°C.
`Revolve N-525 (6056) Natural (appears white coloured) & BH3239 Black (black coloured)`. Polyethylene materials manufactured by rotational moulding. For use with water up to 85°C.
`Revolve N-650/6068 Natural (appears cream coloured) & M-668 Black (black coloured)`. Polyethylene materials manufactured by rotational moulding. For use with water up to 85°C.
'Revolve 6405U Natural (appears white coloured) & Revolve M-1585 Black (black coloured)'. Polyethylene materials manufactured by rotational moulding. For use with water up to 85°C.
‘Revolve N-840 (HD3850) & Revolve M-750 DR Black’. Revolve N-840 (HD3850) is a white coloured polyethylene material & Revolve M-750 DR Black is a black coloured polyethylene material. Both are manufactured by rotational moulding. For use with water up to 85°C. Please note that ‘Revolve N-840 (HD3850)’ was formerly known as ‘Revolve N-840 (6850)’.
'XYRON WG732 AWY2266, WG732 AWY2269, WG732 AWY6628, WG722 AWY6627, W5002 AWY1208, W5002 AWY2267, W5002 AWY6629, W5002 AWY3326, WG722 AWY2261, WG732 AWY3325, WG722 AWY3324 & WG733 ABY3315'. Injection moulded, black, grey or beige coloured PPE materials manufactured in Thailand & China. For use with water up to 85°C.
'Popular PPRC 100 Pipe'. Green coloured, extruded PPR pipe. For use with water up to 60°C.
'ALTECH PP-H FC 3013/500.01 GB13 NC0001-00 (1004864600000)'. Natural (appears white coloured), injection moulded PP-H material. For use with water up to 50°C.
'Hostalen PP H5416T'. White coloured (translucent), extruded polypropylene material. For use with water up to 60°C.
‘PX70N-0201 washers, ‘O’ rings, bushes gaskets & discs’. Black coloured, injection moulded EPDM components with a shore hardness of 70. The washers have a tested in-radius size of 3.0mm. The ‘O’ rings have a tested in-radius size of 3.5mm. The bushes gaskets have a tested in-radius size of 2.0mm. The discs have a tested in-radius size of 2.65mm. All are for use with water up to 85°C.
'60 EPDM 334 black 60 ShA' (shore hardness 60) and '70 EPDM 335 black 70 ShA' (shore hardness 70). Black coloured compression moulded EPDM materials. Tested in-radius 1.07mm. For use with water up to 85°C.
'WRC-70 'O' rings and gaskets'. Black coloured, injection moulded NBR rubber 'O' rings and gaskets. Tested in-radius size between 0.5mm & 2.6mm. Shore hardness 70. For use with water up to 23°C.
‘40SIL310P, 45SIL310P, 50SIL310P(W), 55SIL310P, 60SIL310P, 65SIL310P, 70SIL310P, 75SIL310P & 80SIL310P'. Compression moulded, silicone rubber ‘O’ rings in natural, white, black, red, blue & yellow with tested in-radii sizes of between 0.5mm & 3.4mm. For use with water up to 85°C.
'XR0130012 (30SH), XR0140012 (40SH), XR0150012 (50SH), XR0160012 (60SH) & XR0170012 (70SH)'. Translucent, colourless, compression moulded silicone rubber materials. Shore hardness between 30 & 70. Tested in-radius size 1.5mm. For use with water up to 85°C.
Floor mounted, single hole, single outlet (fixed) combination tap assembly (chromium plated brass), incorporating a ceramic cartridge headwork with single lever operating member and a lockable diverter to shower outlet. The spout outlet incorporates a plastic aerator. The product is supplied with a shower hose and handset. Both the shower outlet (from the main body) and the inlet to the shower handset incorporate an approved check valve cartridge, however, the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.
Range of single hole, single outlet (swivel) combination tap assemblies (various finishes) with a pull-out spray mechanism. Flow is controlled via a ceramic cartridge headwork with a single lever operating member incorporating an infra-red sensor on the swivel arm which operates a solenoid valve. The spout outlet incorporates a plastic aerator and a hand spray mechanism, and the product is supplied with metal backnuts. Maximum working pressure 5.0 Bar. Maximum operating temperature 60°C.
Range of deck mounted, electronically operated combination tap assemblies (chromium plated brass). The flow is controlled by a solenoid valve which is actuated via an infrared sensor on the spout. The spout outlet incorporates a plastic aerator. Maximum working pressure 8.0 bar. Maximum operating temperature 60°C.
Side entry BS1212-4 (2016) compact type float operated valve for WC flushing cisterns. Maximum working pressure 10.0 bar. Cold water use only.
Range of bottom entry BS1212-4 (2016) compact type float operated valve for WC flushing cisterns. The inlet incorporates a plastic strainer. Maximum working pressure 10.0 Bar. Cold water use only.
WC flushing cistern incorporating a bottom entry BS1212-4 (2016) compact type float operated inlet valve providing a Type AG air gap with a dual flush drop valve for full flush volumes of up to 6 litres and a reduced flush of up to 3 litres. The cistern is operated by a pnuematic push button. Maximum working pressure 10.0 bar. Cold water use only.
Range of concealed WC cistern in white plastic incorporating a BS 1212-4:2016 side entry float operated inlet valve providing a Type AG air gap arrangement and a single or dual flush outlet valve. The full flush can be set at 6 litres and the reduced flush can be set at 3 litres. The inlet supply incorporates a servicing valve. Maximum operating pressure 10.0 bar. Cold water use only.
Range of concealed WC cistern in white plastic incorporating a BS 1212-4:2016 side entry float operated inlet valve providing a Type AG air gap arrangement and a single or dual flush outlet valve. The full flush can be set at 6 litres and the reduced flush can be set at 3 litres. The inlet supply incorporates a servicing valve. Maximum operating pressure 10.0 bar. Cold water use only.
BS EN 14055: 2018 concealed WC flushing cistern incorporating a side entry compact type float operated inlet valve providing a Type AB air gap and lever operated syphon capable of full flush volumes of up to 6 litres and reduced flush of up to 4 litres. Maximum working pressure 10.0 bar. Cold water use only.
Range of thermostatic cartridges incorporating brass bodies, stainless steel strainers and EPDM ‘O’-rings. For insertion into specifically dimensioned tap bodies. Maximum working pressure 10.0 bar. Maximum operating temperature 85°C.
Range of deck mounted combination tap assemblies (chromium plated brass) incorporating rising spindle headwork with single lever operating members, swivel spout outlet and separate pull-down spray outlet (with self-closing trigger assembly). The spout outlets incorporate a plastic flow straightener and the products are supplied with metal backnuts. Models 98008-M001 & 98008-1 are single hole, single outlet. Model 98007-1 is two-hole, single outlet. Model 98001-2 is single hole, double outlet. Maximum working pressure 10.0 bar. Maximum operating temperature 65°C.
Range of wall mounted combination tap assemblies (chromium plated brass) incorporating rising spindle headwork with single lever operating members, swivel spout outlet and separate pull-down spray outlet (with self-closing trigger assembly). The spout outlets incorporate a plastic flow straightener and the products are supplied with metal backnuts. Model 98011-1 is single hole, single outlet. Models 98002-1 & 98002-M001 are two-hole, single outlet. Model 98002MN-2 is two-hole, double outlet. Maximum working pressure 10.0 bar. Maximum operating temperature 65°C.
Range of single hole, single outlet (swivel) combination tap assemblies (various finishes) with ceramic cartridge headworks and single lever operating members. The spout outlet incorporates a pull-out spray with plastic aerator. The cold Inlet incorporates approved check valve cartridge, however, the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum operating pressure 5.0 bar. Maximum operating temperature 60°C.
Single hole, single outlet (fixed) combination tap assembly (chromium plated brass). Incorporating a single sequential headwork with a single lever operating member. The spout outlet incorporates a plastic aerator. Product is supplied with a T-Type thermostatic mixing valve. Maximum working pressure 5.0 Bar. Maximum operating temperature 60°C.
Range of single hole, single outlet (fixed) combination tap assemblies incorporating chromium plated or stainless steel plated brass bodies, ceramic cartridge headwork with a single lever operating member. The spout outlets incorporate a plastic aerator. Some models are supplied with a click type waste (fully tested). Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.
Range of single hole, single outlet (fixed) combination tap assemblies (chrome plated brass), incorporating a thermostatic sequential headwork with a single lever operating member. The spout outlet incorporates a plastic aerator. Maximum operating pressure 10.0 bar. Maximum operating temperature 60°C.
Range of single hole, single outlet (swivel) combination tap assemblies (chrome plated or brushed nickel coated brass), with quarter turn ceramic disk headworks and cube operating members. The spout outlet incorporates a plastic flow straightener. Supplied with single check valves (suitable for backflow protection against Fluid Category 2) with integral servicing valve for both inlets. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.
Single hole, single outlet (swivel) combination tap assembly (chrome plated brass) with non-rising spindle headworks and cross top operating members. The spout outlet incorporates a plastic flow straightener. Maximum working pressure 7.0 bar. Maximum operating temperature 60°C.
Single hole, single outlet (swivel) combination tap assembly (chrome plated brass), incorporating quarter turn ceramic disk headwork’s with single lever operating members. The spout outlet incorporates a plastic flow straightener. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.
Single hole, single outlet (swivel) combination tap assembly (chrome plated brass), incorporating non-rising spindle headworks with dome operating members. The spout outlet incorporates a plastic flow straightener. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.
Range of single hole, single outlet (swivel) combination tap assemblies (various finishes) incorporating a ceramic cartridge headwork controlling the hot and cold flow. MAL models incorporate a quarter turn ceramic disc headwork to control a filtered water supply. The spout outlets incorporate a plastic aerator. The inlets incorporate a check valve cartridge verified by test (suitable for backflow protection against Fluid Category 2). Maximum working pressure 5.0 bar. Maximum operating temperature 60ºC.
Range of single hole, single outlet (swivel) combination tap assemblies (various finishes) with ceramic cartridge headworks and single lever operating members. The discharge is via the hand spray outlet or the infra-red controlled outlet on the swivel arm. The cold Inlet has a single check valve assembly (suitable for protection against fluid category 2 backflow). The spouts incorporate a plastic aerator. Maximum operating pressure 5.0 bar. Maximum operating temperature 60°C.
Two-hole, single outlet (fixed) combination tap assembly with a brass body (chromium plated), incorporating quarter turn ceramic disc headworks with single lever operating members. The spout outlet is a waterfall design. The inlets incorporate plastic flow restrictors. The product is supplied with metal backnuts. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.
Range of two hole, single outlet (fixed) combination tap assemblies (chromium plated brass), incorporating quarter turn ceramic disc headworks with single lever operating members. The spout outlets incorporate a plastic aerator. The products are supplied with metal backnuts. Maximum working pressure 8.0 bar. Maximum operating temperature 60°C.
Two hole, single outlet (fixed) combination tap assembly (chromium plated brass), incorporating quarter turn ceramic disc headworks with single lever operating members. The spout outlets incorporate a plastic aerator. The products are supplied with metal backnuts. Maximum working pressure 8.0 bar. Maximum operating temperature 60°C.
Two-hole, single outlet (fixed) combination tap assembly with a brass body (chromium plated), incorporating quarter turn ceramic disc headworks with single lever operating members. The spout outlet is a waterfall design. The inlets incorporate plastic flow restrictors. The product is supplied with metal backnuts. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.
Range of two hole, single outlet (fixed) combination tap assemblies (chromium plated brass). Models 91742, 95660 incorporate a non-rising spindle headwork with dome type operating members. Model 21775 incorporate a non-rising spindle headwork with cross top operating members. Model 77174 incorporate a quarter turn ceramic disc headwork with single lever operating members. The fitting incorporates a manual diverter to the shower outlet The spout outlet incorporates a plastic flow straightener and the products are supplied with a shower hose, shower handset and metal backnuts. Maximum working pressure 10.0 bar. Maximum operating temperature 70°C.
Two-hole, single outlet (fixed) combination tap assembly (chromium plated brass), incorporating quarter turn ceramic disc headwork with single lever operating members and a self-cancelling diverter to shower outlet. The spout outlet incorporates a plastic flow straightener and the product is supplied with a shower hose, shower handset and metal backnuts Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.
Range of two hole, single outlet (swivel) combination tap assemblies (chrome plated brass) incorporating quarter turn ceramic disk headworks and lever operating members. The spout outlet incorporates a plastic flow straightener. Supplied with metal back nuts. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.
Two hole, single outlet swivel combination tap assembly (chrome plated brass), incorporating non-rising spindle headworks with dome operating members. The spout outlet incorporates a plastic flow straightener. The product is supplied with metal backnuts. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.
Two hole, single outlet (swivel) combination tap assembly (chrome plated brass) incorporating non rising spindle headworks with cross top operating members. The spout outlet incorporates a plastic flow straightener. Supplied with metal back nuts. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.
Range of deck mounted thermostatic shower mixers with brass bodies (chrome plated), incorporating ceramic disc headworks with dome type operating members controlling the flow and a lockable self-cancelling diverter to shower outlet. Temperature is controlled independently via a thermostatic cartridge with a dome type operating member that also incorporates a manual override button. Spout outlet incorporates a plastic flow straightener. Both inlets incorporate a single check valve cartridge (however, the complete product has not been fully tested to demonstrate it provides backflow protection) and stainless-steel strainers. Model DYN106 is supplied with a shower hose and shower handset, all other models are supplied with a shower hose, shower handset, riser rail and soap dish. Maximum working pressure 5.0 Bar. Maximum operating temperature 60°C.
Two hole, single outlet (fixed) combination tap assembly (chromium plated brass) incorporating quarter turn ceramic disc headworks with single lever operating members and a lockable self- cancelling diverter to the shower outlet. The waterfall spout outlet incorporates a stainless-steel aerator. The product is supplied with metal backnuts, as well as a shower hose and handset. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C
Range of wall mounted, three-hole, single outlet (fixed) combination tap assemblies (brass body with various finishes) incorporating quarter turn ceramic discs. No operating members supplied. Maximum working pressure 5.5 bar. Maximum operating temperature 60°C.
Three-hole, single outlet (fixed) combination tap assembly with brass body (various finishes), incorporating quarter turn ceramic disc headworks with dome (cube) type operating members. Each inlet incorporates an approved check valve cartridge; however, the complete product has not been fully tested to demonstrate it provides backflow protection. The spout outlets incorporate a plastic aerator. Product is supplied with stainless steel braided, PEX lined connection hoses and pop-up waste. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.
Range of wall mounted, three-hole, single outlet (fixed) combination tap assemblies with brass bodies (various finishes), incorporating quarter turn ceramic disc headworks and dome type operating members. The spout outlet incorporates a plastic aerator. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.
Range of wall mounted (swivel) spout outlets with chromium plated brass bodies, EDPM ‘O’-rings and a plastic flow straightener. DJ suffix models have a double swivel arm. Maximum operating temperature 65°C.
Expansion vessels with a stainless steel body and EPDM membrane. Maximum working pressure 15.0 bar. Maximum operating temperature 100°C.
Range of brass compression fittings for use with copper pipe (manufactured to IS EN 1057). Maximum working pressure 10.0 bar. Maximum operating temperature 99°C.
Range of brass compression fittings for use with copper pipe manufactured to EN1057. Maximum working pressure 16.0 bar. Maximum operating temperature 100°C.
Range of Irish compression fittings with brass bodies, nut and olives for use with Irish copper pipe manufactured to EN1057:2006+A1:2010. Maximum working pressure 16.0 bar. Maximum operating temperature 99°C.
Range of compression fittings incorporating polypropylene bodies, plastic pipe liners, plastic grip rings and EPDM seals. For use with both PE80 & PE100 pipe manufactured to BS EN 12201. For above and below ground use. Maximum working pressure 12.5 bar (PE80 pipe 20mm - 63mm). Maximum working pressure 16.0 bar (PE100 pipe 20mm - 63mm). Maximum working pressure 10.0 bar (PE100 pipe 75mm - 110mm). Cold water use only.
Range of crimp fittings with a bronze body incorporating EPDM O-rings. For use with copper pipe manufactured to EN 1057. Maximum working pressure 16.0 bar. Maximum operating temperature 85°C
Range of capillary end feed bronze fittings for use with copper tube (manufactured to BS EN 1057). 15mm – 54mm fittings have a maximum working pressure of 25.0 bar. 67mm – 108mm fittings have a maximum working pressure of 16.0 bar. Maximum operating temperature 100°C.
Electronically controlled heat interface units (HIU) with twin stainless-steel plate heat exchangers providing space heating and instantaneous hot water. The cold inlet supply to the plate heat exchanger incorporates an isolation valve and a water hammer arrestor. The space heating circuit incorporates an expansion vessel and a pressure relief valve (set at 3.0 bar). The product is supplied with a filling loop assembly consisting of an elbow shaped copper pipe, isolation valve and double check valve assembly (suitable for backflow protection against fluid category 3) which incorporates an isolation valve. The cold mains inlet and the domestic hot water outlet each incorporate a brass bodied spherical valve with a butterfly handle. Maximum working pressures and operating temperatures: Primary: 16.0 bar and 90˚C. Domestic hot water (DHW): 10 bar and 65˚C. Secondary (space heating): 2.5 bar and 85˚C.
Copper heat transformer. Maximum working pressure 11.0 bar. Maximum operating temperature 95°C.
Range of domestic hot water units incorporating instantaneous or semi-instantaneous plate heat exchanger assemblies. The product incorporates a motorised control valve, managed primary and secondary pumps (see model), and a drain valve on both circuits. Maximum working pressures: 10.0 bar primary, 9.5 bar secondary. Maximum operating temperatures: 110°C primary, 85°C secondary.
Range of unvented electric storage water heaters consisting of a mild steel, glass/enamel coated tank, heating element and pressure relief valve set at 6.0 bar. Maximum working pressure 5.5 bar. Maximum operating temperature 75°C.
Ranges of wall hung, gas-fired condensing combination boilers providing domestic hot water via a plate heat exchanger and pressurised central heating system incorporating an expansion vessel and pressure relief valve set at 3.0 bar. The supplies to both domestic hot water and primary are controlled via spherical valves. Products are supplied with a rigid filling loop or keyless filling link. Maximum working pressure of the primary circuit is 2.5 bar & maximum supply pressure of the secondary circuit is 8.0 bar. Cold water supply only. Maximum operating temperature 95°C.
Q4000 range of water meters incorporating stainless steel bodies, FKM rubber gasket and grey epoxy resin liner. Maximum working pressure 16.0 bar. Cold water use only.
H4000 range of helical rotor bulk water meters, with blue epoxy coated cast iron bodies and NBR ‘O’-rings. Maximum working pressure 16.0 Bar. Cold water use only.
Range of flow meters incorporating black epoxy coated ductile iron bodies and EPDM ‘O’-rings. Maximum working pressure 16.0 bar. Maximum operating temperature 50°C.
Range of 2,3 or 4 way manifolds incorporating a nickel plated brass body with non-rising spindle stop valves. Maximum working pressure 10.0 bar. Maximum operating temperature 95°C.
Range of shower outlet elbows with brass bodies (chrome plated,with exception of model 27.076.LS0). Some models incorporate a shower handset holder. The outlet incorporates a check valve cartridge, however, the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum operating temperature 60°C.
Range of in-line flow sensors with a plastic body, turbine and impeller case. Maximum working pressure 25.0 bar. Cold water use only.
Range of compact wall outlet assemblies with plastic bodies (chromium plated) and EPDM ‘O’-rings. Maximum working pressure 5.0 bar. Maximum operating temperature 55°C.
Screw down elbow servicing valve with brass body (brushed chrome) which is intended to connect to an appliance, e.g. washing machine, dishwasher to the water supply. Maximum working pressure 10.0 bar. Maximum operating temperature 70°C.
Range of threaded fittings with either plain brass, nickel plated brass or chrome plated brass bodies. Maximum operating pressure 16.0 bar. Maximum operating temperature 99°C.
Concealed wall insulation unit with a brass body and EPDM ‘O’-rings. Maximum working pressure 10.0 bar. Maximum operating temperature 80°C.
Range of isolation valves with a brass body (various surface finishes - see model) and either a quarter turn ceramic disc (PEX-230-C/P and PEX-231-C/P models) or a non-rising spindle (all other models) with various operating members (see model) and NBR ‘O’-rings. The inlet of the PEX-230-C/P and PEX-231-C/P models incorporates a stainless-steel strainer. Maximum working pressure 10.0 bar. Maximum operating temperature 85°C.
Range of inline circulating pumps with bronze bodies, plastic impeller and EPDM rubber seals. Maximum working pressure 10.0 bar. Maximum operating temperature 100°C.
Range of booster pumps with plastic bodies and impellers, EPDM ‘O’-rings and stainless steel inlet manifolds. The product incorporates a non-return valve. The ESYBOX MAX single models are also supplied with an optional 2” BSP (M) x 1¼” BSP (F) plastic inlet adaptor. Maximum working pressure 12.0 bar. Cold water use only.
Multistage, vertical booster pumps with a brass body and stainless steel pump housing, stainless steel impellers and EPDM ‘O’-rings. The 41782 (MV90 4M VSD) model includes a pressure transducer. Maximum working pressure 6.0 bar. Cold water use only.
Range of multistage centrifugal pumps with stainless steel bodies and impellers, and EPDM ‘O’-rings. Maximum operating pressure 11.0 bar. Maximum working temperature 90°C.
Range of horizontal self-priming multistage pumps with stainless steel bodies, stainless steel impellers, shaft and outer sleeve. Maximum working pressure 10.0 Bar Maximum operating temperatures: EH Three phase models 85°C, EH Single phase models 55.0°C and EHsp models 35°C.
Range of self-priming pumps with stainless steel bodies and impellers, and EPDM ‘O’-rings. Maximum working pressure 7.0 bar. Cold water use only. From November 2021 maximum operating temperature 60°C
Range of single stage end suction pumps with stainless steel or cast iron pump housings, EPDM ‘O’-rings and wear rings available in low-lead bronze/brass or stainless steel. Cast iron models are coated in black cathodic paint (textured finish) or black epoxy (smooth finish). The pumps are available with carbon graphite/silicon carbide mechanical shaft seal. Impellors are available in cast iron with black cathodic paint, low-lead bronze or stainless steel. The pumps are available with fixed flange, as well as loose flange (model dependent). Maximum working pressure 10.0 or 16.0 bar depending on model. Maximum operating temperatures: Stainless steel and cast iron with (smooth) epoxy coating pumps 85°C. Cast iron pumps with (textured) cathodic paint coating are cold water use only.
Range of inline circulating pumps with bronze bodies, plastic impeller and EPDM rubber seals. Maximum working pressure 10.0 bar. Maximum operating temperature 100°C.
Range of booster pumps with stainless steel bodies and impellers, EPDM ‘O’-rings and a ceramic/graphite/EPDM shaft seal. Maximum working pressure 6.0 bar. Maximum operating temperature 40°C.
Range of booster pumps with stainless steel bodies and impellers, EPDM ‘O’-rings and a ceramic/graphite/EPDM shaft seal. Maximum working pressure 7.0 bar. Cold water use only. From November 2021 maximum operating temperature 60°C
Range of shower handsets incorporating chromium plated plastic or chromium plated brass bodies (see model). Inlets incorporate a plastic flow regulator. Maximum operating temperature 60°C.
Range of overhead shower outlets incorporating brass bodies (chrome plated) and EPDM gaskets. Inlets have stainless filters incorporated within a ball joint. Maximum operating temperature 85°C
Range of overhead shower outlets (chrome plated plastic bodies). Inlets incorporate a strainer. Maximum operating temperature 85°C
Range of shower outlets with brass bodies (various finishes) incorporating NBR ‘O’-rings (280R/W model) or EPDM ‘O’-rings (286P/W model). The inlet of the 286P/W model incorporates a plastic flow regulator. Maximum operating temperature 60°C.
Range of wall mounted shower outlets (brass bodies), shower hoses and handsets available in various finishes (see model). The shower outlet incorporates an approved check valve cartridge, however, the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum operating temperature 60°C.
Shower head (various finishes) with a built in flow restrictor. Maximum operating temperature 60°C.
Range of shower handsets with chrome plated bodies and built in flow restrictors. Maximum operating temperature 60°C.
Range of rim/deck mounted shower handsets with brass bodies (various finishes). The inlet (except for the D5A A02 60A/W model) incorporates an approved check valve cartridge, however, the complete product has not been fully tested to demonstrate it provides backflow protection. The inlet of the D5A A02 60A/W model incorporates a plastic flow restrictor. The products are supplied with a shower hose and a stainless steel braided EDPM lined flexible hose assembly (for connection prior to the shower hose). Maximum working temperature 60°C.
Range of shower rose outlets (plastic body with various finishes). The inlet incorporates a stainless-steel strainer. Maximum operating temperature 60°C. Open outlet use only.
Range of shower outlets with brass bodies (various finishes) incorporating NBR ‘O’-rings. Maximum operating temperature 60°C.
Range of ceiling tubes (brass bodies - various finishes) intended for use with shower heads. Maximum operating temperature 85°C.
Range of inline ‘Y’- patterned strainers with brass bodies & stainless steel filters. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.
Range of flow switches with brass bodies incorporating EPDM ‘O’-rings, acting as a leak detection system that actuates an integral spherical valve to shut off the water supply. The inlet incorporates a stainless steel strainer. The outlet incorporates an approved check valve cartridge, however, the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum working pressure 16.0 bar. Maximum operating temperature 30°C.
Range of bib taps incorporating either brass or DZR brass bodies. The inlet and the outlet of the tap incorporates approved single check valve cartridges however, the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum working pressure 16.0 bar. Maximum operating temperature 85°C.
Range of wall mounted hose union taps (brass, chrome plated brass or DZR brass body) incorporating a non-rising spindle headwork with a butterfly handle operating member. Maximum working pressure 16.0 bar. Maximum operating temperature 85°C.
Range of pillar taps (chrorme plated brass) with ¼ turn ceramic disc headworks and lever operating members. The spout outlet incorporates a plastic flow straightener. The product is supplied with metal backnuts. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.
Range of pillar taps (chrorme plated brass) with ¼ turn ceramic disc headworks and lever operating members. The spout outlet incorporates a plastic flow straightener. The product is supplied with metal backnuts. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.
Range of pillar taps with brass bodies (chrome plated), incorporating quarter turn ceramic disc headwork with single lever operating members. The spout outlets incorporate a plastic flow straightener or aerator. The product is supplied with metal backnuts. Maximum working pressure 10.0 bar. Maximum operating pressure 85°C.
Range of pillar taps (chrorme plated brass) with ¼ turn ceramic disc headworks and lever operating members. The spout outlet incorporates a plastic flow straightener. The product is supplied with metal backnuts. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.
Range of pillar taps (chrorme plated brass) with ¼ turn ceramic disc headworks and lever operating members. The spout outlet incorporates a plastic flow straightener. The product is supplied with metal backnuts. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.
Range of TPE and TPS lined flexible hose assemblies incorporating NBR ‘O’-rings and various end connections. Maximum operating temperature 60°C.
Range of chromium plated stainless steel or brass interlocked shower hoses with an optional PVC outer layer. Incorporating either a PVC or TPE inner hose and EPDM gaskets. Maximum operating temperature 60°C.
Range of stainless steel braided or nylon braided EPDM lined hose assemblies available with a variety of end connectors. Maximum working pressure 10.0 bar. Maximum operating temperature 90°C.
Elite ranges of Direct, Indirect, Solar Single, Solar Twin, Slim Direct and Slim Indirect stainless steel insulated unvented hot water storage cylinders with external expansion. The DHW circuit consists of a temperature and pressure relief valve set at 7.0 bar and 90°C, an inlet control group consisting of a pressure reducing valve adjustable between 2.7 and 3.3 bar, an expansion relief valve (SRV) set at 6.0 bar, a strainer and a check valve cartridge, verified by test (suitable for backflow protection against Fluid Category 2) also supplied with a tundish. Maximum supply pressure to the inlet control group 10.0 bar. Maximum working pressures - Primary circuit 6.0 bar, Secondary circuit 5.5 bar. Maximum operating temperature 65˚C.
Flowcyl ranges of Direct, Indirect, Solar Single, Solar Twin, Slim Direct and Slim Indirect stainless steel insulated unvented hot water storage cylinders with external expansion. The DHW circuit consists of a temperature and pressure relief valve set at 7.0 bar and 90°C, an inlet control group consisting of a pressure reducing valve adjustable between 2.7 and 3.3 bar, an expansion relief valve (SRV) set at 6.0 bar, a strainer and a check valve cartridge, verified by test (suitable for backflow protection against Fluid Category 2) also supplied with a tundish. Maximum supply pressure to the inlet control group 10.0 bar. Maximum working pressures - Primary circuit 6.0 bar, Secondary circuit 5.5 bar. Maximum operating temperature 65˚C.
Nucyl ranges of Direct & Indirect stainless steel insulated unvented hot water storage cylinders with external expansion. The DHW circuit consists of a temperature and pressure relief valve set at 7.0 bar and 90°C, an inlet control group consisting of a pressure reducing valve adjustable between 2.7 and 3.3 bar, an expansion relief valve (SRV) set at 6.0 bar, a strainer and a check valve cartridge, verified by test (suitable for backflow protection against Fluid Category 2) also supplied with a tundish. Maximum supply pressure to the inlet control group 10.0 bar. Maximum working pressures - Primary circuit 6.0 bar, Secondary circuit 5.5 bar. Maximum operating temperature 65˚C.
Range of free standing direct gas fired unvented cyliners with a enamel coating internal lining and magnesium sacrificial anode. Fitted with a combined temperature and pressure relief valve set at 7 bar. Maximum working pressure 6.5 bar. Maximum operating temperature 80°C.
Range of “POWERflow” Indirect and direct unvented storage cylinders consisting of factory fitted single or twin coil circuit with either a primary or solar coil. The secondary circuit is factory fitted with a temperature and pressure relief valve set at 4.5 bar at 90˚C and an expansion relief valve set at 3.5 bar. The product is supplied with a pressure reducing valve set at 2.1 bar, expansion vessel, tundish and an approved check assembly (suitable for backflow protection against Fluid Category 2). Primary circuit max working pressure: 3.5 bar Secondary circuit max working pressure: 3.0 bar Solar Coil max working pressure: 3.5 bar Primary and Secondary circuit maximum operating temperature 75.0°C Solar Coil max operating temperature 80.0°C
Range of air venting valves incorporating an epoxy coated, iron body and a drain point. Maximum working pressure 16.0 bar. Maximum operating temperature 60˚C.
Range of air venting valves with a blue epoxy coated ductile iron body and carbon steel cover, NBR ‘O’-rings and EPDM seals. Maximum working pressure 10.0 bar or 16.0 bar (see model). Maximum operating temperature 65°C.
Range of air venting valves incorporating an epoxy coated, iron body and a drain point. Maximum working pressure 16.0 bar. Maximum operating temperature 60˚C.
Concealed, wall mounted, manual shower blending valve incorporating a brass body, ceramic cartridge headwork and a self-cancelling diverter to a second shower outlet. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.
Wall mounted, concealed, manual blending valve with DZR brass body and chrome plated trim set, incorporating a quarter turn ceramic disc headwork controlling the flow and a ceramic cartridge controlling the temperature independently, bothwith dome type operating members. The inlets incorporate approved check valve cartridges, however, the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.
Wall mounted thermostatic shower valve (chromium plated brass bodies), incorporating a quarter turn ceramic disc headwork diverting the flow between overhead shower and handset with dome type operating member. Temperature is controlled independently via a thermostatic cartridge with a dome type operating member that incorporates a manual override button. The product incorporates a fixed riser and overhead shower and is supplied with a shower hose and handset. Both inlets incorporate stainless steel strainers and approved check valve cartridges, however, the complete products have not been fully tested to demonstrate that they provide backflow protection. Maximum working pressure: 5.0 Bar Maximum operating temperature: 60°C
Wall mounted thermostatic shower valve (chromium plated brass bodies), incorporating a quarter turn ceramic disc headwork diverting the flow between overhead shower and handset with dome type operating member. Temperature is controlled independently via a thermostatic cartridge with a dome type operating member that incorporates a manual override button. The product incorporates a fixed riser and overhead shower and is supplied with a shower hose and handset. Both inlets incorporate stainless steel strainers and approved check valve cartridges, however, the complete products have not been fully tested to demonstrate that they provide backflow protection. Maximum working pressure: 5.0 Bar Maximum operating temperature: 60°C.
Wall mounted thermostatic shower valve (chromium plated brass bodies), incorporating a quarter turn ceramic disc headwork diverting the flow between overhead shower and handset with cube type operating member. Temperature is controlled independently via a thermostatic cartridge with a cube type operating member that incorporates a manual override button. The product incorporates a fixed riser and overhead shower and is supplied with a shower hose and handset. Both inlets incorporate stainless steel strainers and approved check valve cartridges, however, the complete products have not been fully tested to demonstrate that they provide backflow protection. Maximum working pressure: 5.0 Bar Maximum operating temperature: 60°C.
Wall mounted thermostatic shower valve (chromium plated brass bodies), incorporating a quarter turn ceramic disc headwork diverting the flow between overhead shower and handset with cube type operating member. Temperature is controlled independently via a thermostatic cartridge with a cube type operating member that incorporates a manual override button. The product incorporates a fixed riser and overhead shower and is supplied with a shower hose and handset. Both inlets incorporate stainless steel strainers and approved check valve cartridges, however, the complete products have not been fully tested to demonstrate that they provide backflow protection. Maximum working pressure: 5.0 Bar Maximum operating temperature: 60°C.
Range of wall mounted, exposed, thermostatic bar type shower mixing valves (chromium plated brass). The F061 & 081 prefix models incorporate a 2-way ceramic disc diverter headwork with dome (F06 prefix models) or cubed type (F08 prefix models) operating members controlling the flow either shower outlet. The F062 & 082 prefix models incorporate a ¼ turn ceramic disc headwork with dome (F06 prefix models) or cubed type (F08 prefix models) operating members controlling the flow to a single shower outlet. The temperature is controlled independently via a thermostatic cartridge. The inlets incorporate stainless steel strainers and approved check valve cartridges however, the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum working pressure 5.0 bar. Maximum operating temperature 80°C.
Wall mounted, exposed, thermostatic bar type shower mixing valve (chromium plated brass) incorporating a 2-way ceramic disc diverter headwork with a dome type operating member, which diverts the flow between outlets. Temperature is controlled independently via a thermostatic cartridge with a dome type operating member incorporating a manual override button. Both inlets incorporate a combined NBR washer and stainless steel strainer and an approved single check valve cartridge, however the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.
Wall mounted thermostatic shower valves with a chromium plated brass body incorporating a spindle headwork controlling the flow and a separate thermostatic cartridge controlling the temperature, both using single lever operating members. Both inlets incorporate flow regulators, strainers and a single check valve cartridge, however, the complete product has not been fully tested to demonstrate it provides backflow protection. Supplied with shower hose, shower handset and riser rail. Maximum working pressure 10.0 bar. Maximum operating temperature 65°C.
Range of wall mounted, thermostatic blending valves with brass bodies (chrome plated), incorporating a quarter turn ceramic disc headwork controlling the flow with a dome type or single lever operating member. The temperature is controlled independently via a thermostatic cartridge with a dome type or single lever operating member which incorporates a manual override button. The inlets incorporate a combined NBR washer and stainless strainer and an approved check valve cartridge, however, the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum working pressure 5.0 bar. Maximum operating temperature 80°C.
‘Ausimix’ compact range of ‘T’-type thermostatic blending valves with nickel plated DZR brass bodies. Each inlet incorporates a stainless-steel strainer and a single check valve cartridge, verified by test (suitable for backflow protection against Fluid Category 2). The SBHEAT110780, SBHEAT110785, HEAT110780 & HEAT110785 models also have angled isolation valves at both inlets. Maximum working pressures and operating temperatures: Existing push fit models: For use with PEX pipe (manufactured to BS7291 part 3) and Polybutylene pipe (manufactured to BS7291 part 2): 12.0 bar, cold water use only. 6.0 bar @ 95°C. For use with copper pipe: Maximum working pressure 10.0 bar. Maximum operating temperature 95°C. Compression models added October 2023: For use with copper pipe to BSEN1057:2006: Maximum working pressure 10.0 bar. Maximum operating temperature 85°C.
Range of wall mounted, thermostatic, shower mixers incorporating brass bodies (various finishes) 2-way ceramic disc diverter headwork to control the flow between two shower outlets with various operating members (see model). The A47203VUK model uses two ‘detent’ (push to on push to off) headworks to control the flow to each outlet. Temperature is controlled independently via a thermostatic cartridge using various operating members (see model) that also incorporates a manual override button. The inlets incorporate a combined EPDM washer and stainless-steel strainer or stainless steel strainer (A47203VUK model) and an approved check valve cartridge, however, the complete product has not been fully tested to demonstrate it provides backflow protection. The inlet of the overhead shower incorporates a combined EPDM washer and stainless-steel strainer. The products are supplied with a shower head, shower hose and handset. Maximum working pressure 10.0 Bar. Maximum operating temperature 60°C.
Wall mounted thermostatic blending valve (chromium plated brass) incorporating ceramic disc headwork controlling the flow. Temperature is controlled independently via a thermostatic cartridge incorporating a manual override button. The product is supplied with dome type operating members. The inlets incorporate a stainless steel strainer and single check valve cartridge (however the complete assembly has not been tested to demonstrate it provides adequate backflow). Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.
Range of wall mounted, exposed, thermostatic shower mixing valves with brass bodies (various finishes - see model) incorporating a quarter turn ceramic disc headwork controlling the flow with a dome type operating member. The temperature is controlled independently via a thermostatic cartridge with a dome type operating member that also incorporates a manual override button. Both inlets incorporate a combined NBR washer and stainless-steel strainer, as well as an approved single check valve cartridge, however, the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.
Range of handwheel operated butterfly valves with blue epoxy coated ductile iron bodies, EPDM seat and stainless-steel disc. Maximum working pressure 16.0 bar. Maximum operating temperature 85°C.
Range of butterfly valves incorporating blue epoxy coated ductile iron bodies, stainless-steel discs and EPDM seats. Maximum working pressure 16.0 bar. Maximum operating temperature 85ºC.
Range of wafer and lugged type butterfly valves incorporating blue epoxy coated cast iron bodies, stainless steel discs and EPDM seat. The closing mechanism can be controlled by either a lever, gear or bore shaft. Maximum working pressure 16.0 bar. Maximum operating temperature 85°C.
Concealed flow control valve with a brass body incorporating a quarter turn ceramic disc headwork with a single lever operating member. Maximum working pressure 5.0 bar. Maximum operating temperature 65°C.
Range of adjustable, in-line pressure reducing valves with DZR brass bodies. Adjsutable between 1.0 bar and 5.5 bar outlet pressure. Compression models are for use with copper pipe to EN1057. Maximum inlet supply pressure 16.0 bar. Maximum operating temperature 80°C.
Range of pressure reducing valves with DZR brass bodies (CW602N or CW511L), EPDM ‘O’-rings and a stainless steel strainer. Available with a variety of end connections (see model). Models with compression, pressfit and pushfit connections are for use with copper pipe. Maximum inlet supply pressure 16.0 bar. Maximum outlet pressure between 1.5 bar and 6.0 bar. Maximum operating temperature 80°C.
Range of manually adjustable pressure reducing valves with DZR brass bodies and EPDM ‘O’- rings. Maximum inlet pressure 15.0 bar, adjustable outlet range of 2.2 to 4 bar. Maximum operating temperature 60°C.
Range of adjustable, pilot operated pressure reducing control valves with ductile iron bodies (blue epoxy coated) EPDM diaphragm and NBR ‘O’-rings. The products are supplied with auxiliary stainless-steel tubing, fittings, strainer, pilot valve and needle valve. Maximum inlet supply pressure 16.0 bar. Maximum outlet pressure 1.5 bar - 8.0 bar. Maximum operating temperature 80°C.
Range of plastic bodied solenoid valves incorporating a stainless steel spring and armature with an EPDM diaphragm. Maximum working pressure 10.0 bar. Maximum operating temperature 85°C.
Range of normally closed and normally open plastic solenoid valves with EPDM ‘O’-rings and sealing rings. Pushfit connections for use with John Guest LLDPE pipe or copper pipe. The 47.004.103 model acts as a diverter between two outlets, where one outlet is always open. Maximum working pressures see model section. Maximum operating temperatures: 65°C - 47.00X.1XX models with John Guest LLDPE pipe only. 90°C - 47.004.103 model with John Guest LLDPE pipe only. Models added January 2021: Cold water use only - 47.00X.2XX (4mm & 8mm) with John Guest LLDPE pipe only. 90°C - 47.00X.2XX (6mm) with John Guest LLDPE pipe only. 90°C - 47.00X.2XX (6mm & 8mm) with copper pipe only.
Isolation valve incorporating a brass body (chromium plated) and brass ball (chromium plated). Maximum working pressure 10.0 bar. Cold water use only.
Range of lever operating spherical valves incorporating brass bodies (nickel plated), brass ball (chromium plated) and PTFE seat. Maximum working pressure 16.0 bar. Maximum operating temperature 85°C.
‘Aladdin Easyfit Isolator Pro’ valve incorporating a stainless steel body and self cutting blade to enable a connection to a pressurised or wet systems. For use with copper pipe to BS2871 – EN1057. Maximum working pressure 16.0 bar. Maximum operating temperature 85°C.
Range of gate valves incorporating ductile iron epoxy coted bodies and with EPDM ‘O’-ring seals and discs. The valves are operated via a non-rising spindle with a hand wheel operating member Maximum working pressure 16.0 bar. Maximum operating temperature 85°C.
Range of non-rising gate valves with blue epoxy coated ductile iron body and EPDM rubber coated wedge. Maximum working pressure 16.0 bar. Maximum operating temperature 80°C
Range of gate valves with blue epoxy coated ductile iron bodies, a ductile iron wedge encapsulated in EPDM rubber, PTFE seals and EPDM gaskets and ‘O’-rings. The valves are operated via a non-rising spindle with a hand wheel operating member. Maximum working pressure 16.0 bar. Maximum operating temperature 80°C.
Range of gate valves with brass bodies, brass wedges and PTFE packing glands. The valves are operated via a non-rising spindle with a hand wheel operating member. Maximum working pressure 16.0 bar. Maximum operating temperature 65°C.
5 way manifold assembly with a DZR brass body incorporating a pressure reducing valve, with an adjustable outlet pressure range between 1.0 and 6.0 bar and a safety relief valve set at 6.0 bar. The product incorporates an inline single check valve cartridge after the balanced cold take off, verified by test (suitable for backflow protection against Fluid Category 2). Maximum supply pressure 16.0 bar. Maximum operating temperature 40°C
‘Series 116’ range of automatic thermal balancing valves (DZR Brass) with non-rising spindle headwork, brass disc and EPDM seals. Some models can be supplied with a thermometer (see model). The outlet of the 116144, 116154, 116244 & 116254 models (added January 2024) incorporate a check valve cartridge, verified by test (suitable for backflow protection against fluid category 2). Maximum working pressure 16.0 bar. Maximum operating temperature 100°C.
Range of water conditioners. The WFL38 model has a brass body, all other models are stainless steel. Operating parameters: GRANDER® Inline units - Maximum working pressure 10.0 bar. Maximum operating temperature 95°C. GRANDER® Flexible unit - Maximum working pressure 6.0 bar. Maximum operating temperature 75°C. GRANDER® Apartment unit & Immersion units - Maximum working pressure 10.0 bar. Maximum operating temperature 90°C.
Range of ion exchange water softeners (salt regenerated) for domestic use. Maximum working pressure 6.0 bar. Cold water use only.
Range of polyethylene pressure vessels with spun (blue) fibre glass casing. Maximum working pressure 10.0 bar. Maximum operating temperature 50°C.
‘Hostaform® C9021 ECO-B NATURAL, C9021, M15HP, C2521, C13021, C13031, C27021 ECO-B NATURAL, C27021, C52021 & M90JG’. Injection moulded, natural (which appear to be white) acetal materials available in the following colours: Black 14 DW (formerly known as Black 14), White 22, Grey 33, Grey 36, Grey 39, Red 46, Red 47, Yellow 56, Brown 65, Green 76, Blue 87, RAL 2010, RAL 4008 & RAL 5005. Customer specific colours may also be provided with a nomenclature following the structure ‘xx/yyyy DW’ where ‘yyyy’ denotes the specific colour shade, ‘DW’ denotes ‘Drinking Water’ & ‘xx’ denotes 10 – black, 20 - white (incl. Cream, 30 – grey, 40 – red (incl. Pink), 50 – yellow, 60 – brown (incl. Beige), 70 – Green & 80 – blue. For use with water up to 65°C.
'Deep High Build Liquid Bitumen Paint'. Factory applied, black coloured bitumen paint. Apply and cure as per manufacturer's instructions reference 'DI/BP/2021/011' dated April 15, 2021. For use with water up to 60°C.
'Sealcoat Black'. Black coloured, factory applied petroleum bituminous coating. Apply as per manufacturer's instructions for use reference 'PC 819' dated March, 26, 2021. Cure for 18 hours at 30°C. For use with water up to 23°C. This material is only approved for the curing conditions that appear on the approval. If the cure conditions are varied from those specified on the approval then the material is not covered by the scope of the approval. Petroleum or asphaltic bitumen, NOT coal tar bitumen. Materials listed in this section are not approved for use for contact with water that is required to be wholesome on large water retaining structures such as lining of pipes, cisterns or water storage tanks.
'P658RC & CY10C washers'. P658RC is a black coloured, polyester resin impregnated carbon washer. CY10C is a dark grey coloured, phenolic resin impregnated carbon washer. For use with water up to 85°C.
'Unitech DIP Sulphate Cement'. Factory applied, grey coloured sulphate cement. Mix as per work instructions issue no. 'QAP-MOS-UNITECH 212-13- rev1', dated 21st December 2020. Cure for 6 hours@40°C. For use with water up to 65°C. This material is only approved for the curing conditions that appear on the approval. If the cure conditions are varied from those specified on the approval then the material is not covered by the scope of the approval.
'JIZJ-2'. Factory applied, grey coloured Sulphate resistant Portland cement. Mix cement, sand & water in a 1:1.7:0.55 mass ratio. Cure for 5.5 hours@65°C. For use with water up to 65°C. This material is only approved for the mixing and curing conditions that appear on the approval. If the mixing and/or curing conditions are varied from those specified on the approval then the materials are not covered by the scope of the approval.
'BGDI01 Sulphate Resistant Cement & BGDI02 Portland Cement'. Factory applied, grey coloured cements. Mix 1 part cement, 2 parts sand and 0.25 parts water. Cure for 10 hours@23°C. For use with water up to 65°C. These materials are only approved for the mixing and curing conditions that appear on the approval. If the mixing and/or curing conditions are varied from those specified on the approval then the materials are not covered by the scope of the approval.
'PMSP5065-M'. Factory applied, blue coloured Vitreous Enamel coating. Apply and cure as per user instructions reference 'PEM 37' dated '14/10/2020'. For use with water up to 85°C.
'Parasakti Sulphate Resisting Portland Cement'. Factory applied, grey coloured Sulphate Resistant cement mortar. Mix cement, sand and water in a 1: 1.5: 0.5 ratio. Cure for 28 days@5°C. For use with water up to 65°C. This material is only approved for the mixing and curing conditions that appear on the approval. If the mixing and/or curing conditions are varied from those specified on the approval then the materials are not covered by the scope of the approval.
'Rashmi Cement 43 Grade OPC'. Factory applied, grey coloured Ordinary Portland cement mortar. Mix cement, sand and water in a 1: 1.5: 0.5 ratio. Cure for 28 days@5°C. For use with water up to 65°C. This material is only approved for the mixing and curing conditions that appear on the approval. If the mixing and/or curing conditions are varied from those specified on the approval then the materials are not covered by the scope of the approval.
'LSR Soft Touch Coating – Kohler NC001'. Factory applied, three-component, clear silicone coating. Mix coating, catalyst and thinner in a 100:2:500 mass ratio, stir for 10 minutes and then apply. Cure for 10 minutes@160°C, humidity 60%. For use with water up to 70°C. This material is only approved for the mixing and curing conditions that appear on the approval. If the mixing and/or curing conditions are varied from those specified on the approval then the materials are not covered by the scope of the approval.
‘EUROKOTE® 46-20’. Factory applied, red-brown coloured, two-part epoxy resin coating. Mix and apply as per manufacturer's technical data sheet 'Doc. 087' dated 01/07/2011. Cure for 7 days@20°C. For use with water up to 23°C. This material is only approved for the curing conditions that appear on the approval. If the cure conditions are varied from those specified on the approval then the material is not covered by the scope of the approval.
'Kubotapowder TK1413F'. Factory applied, grey coloured epoxy resin coating. Apply as per manufacturer's instructions 'GR-294E' dated 2018/10/01. Cure for 20 minutes@180°C. For use with water up to 60°C. This material is only approved for the curing conditions that appear on the approval. If the cure conditions are varied from those specified on the approval then the material is not covered by the scope of the approval.
'WB-108'. Factory applied, two-component, grey coloured epoxy coating. Mix, apply and full cure (7 days@20°C) as per manufacturer's technical data sheet 'file no. TWJ-WB-108', 'edition: A1' dated 01/12/2020. For use with water up to 65°C.
'EPOXY TB BT Grey RAL 7016'. Factory applied, grey coloured, fusion bonded epoxy coating. Apply as per Technical Data Sheet 'document version:1' dated 'June 22, 2021'. Cure for 10 minutes@160°C. For use with water up to 65°C. This material is only approved for the curing conditions that appear on the approval. If the cure conditions are varied from those specified on the approval then the material is not covered by the scope of the approval.
'Acrylatik'. Site applied, Acrylate primers available in white, red, blue and black colours. Apply as per manufacturer's instructions 'Appendix No. 1, TU 2316-002-92 872914-2016' dated '11.02.2016'. Cure for 20 minutes@20°C and then 20 minutes@90°C. For use with water up to 23°C. This material is only approved for the curing conditions that appear on the approval. If the cure conditions are varied from those specified on the approval then the material is not covered by the scope of the approval.
'Superfast Potable Water (SFPW)'. Site applied, grey coloured (once mixed), two-component epoxy putty. Mix Part A (white coloured putty) with Part B (cream coloured putty) in a 1:1 mass ratio and apply as per manufacturer's instructions 'SOP Number RM1 version 1.0', dated '06/10/2022'. Cure for 24 hours@20°C. For use with water up to 23°C. This material is only approved for the mixing and curing conditions that appear on the approval. If the mixing and/or curing conditions are varied from those specified on the approval then the materials are not covered by the scope of the approval.
'Solico Ivory GRP Panel'. Beige coloured, compression moulded GRP panel. For use with water up to 60°C.
'Extralite Pipe'. Light green/brown coloured GRP pipe manufactured by filament winding. For use with water up to 60°C.
'Extralite Fitting'. Brown coloured GRP fitting manufactured by hand lay-up. For use with water up to 60°C.
'ajpipe GRP Pipe'. Beige coloured GRP pipe manufactured by continuous filament winding. For use with water up to 23°C. From February 2024, the pipe is for use with water up to 60°C.
'JUSTLINK® JLPEX'. Single layered, off-white (translucent), extruded PEX hose. For use with water up to 60°C.
'Purolite® A600E/9149'. Yellow coloured ion exchange resin. For use with water up to 23°C.
'Purolite® A860S'. White coloured ion exchange resin. For use with water up to 23°C.
'FS Sill Tech Grease'. Off-white coloured (opaque) silicone grease. Apply as per manufacturer's instructions. For use with water up to 65°C.
'SAGITTA VP 763 Silicone Grease'. White coloured, opaque silicone grease. Apply as per manufacturer's instructions. For use with water up to 85°C.
‘4TECH 9G22130 W-A ABK, 4TECH 9G22135 W-A ABK, 4TECH 9G22140 W-A ABK, 4TECH 9G22145 W-A ABK, 4TECH 9G22150 W-A ABK, 4TECH 9G22155 W-A ABK & 4TECH 9G22160 W-A ABK’. Black coloured, glass-fibre reinforced PA66 materials. For use with water up to 23°C.
‘4MID 9A22130 HW-A ABK, 4MID 9A22135 HW-A ABK, 4MID 9A22140 HW-A ABK, 4MID 9A22145 HW-A ABK & 4MID 9A22150 HW-A ABK’. Black coloured, glass-fibre reinforced PA66 materials. For use with water up to 23°C.
'Mapex® AN4920SN FWB50 & GITOP® G3A2 M01FWB'. Black coloured, injection moulded, glass fibre reinforced PA66 materials. For use with water up to 85°C.
'Grilon BG-30/2 natural (appears cream in colour) & Grilon BG-30/2 black 9697 (black coloured)'. Injection moulded PA-GF30 materials. Grilon BG-30/2 black 9697 is for use with water up to 85°C. Between 1st October 2020 and 10th May 2022, Grilon BG-30/2 natural was for use with water up to 23°C. Between 11th May 2022 and 31st October 2025 Grilon BG-30/2 natural is for use with water up to 60°C.
AKROMID® A3 GF 25 8 HU natural (8120) AKROMID® A3 GF 30 8 HU natural (8102) AKROMID® A3 GF 33 8 HU natural (8128) AKROMID® A3 GF 35 8 HU natural (8121) AKROMID® A3 GF 40 8 HU natural (8122) AKROMID® A3 GF 43 8 HU natural (8130) AKROMID® A3 GF 45 8 HU natural (8123) AKROMID® A3 GF 50 8 HU natural (8124) AKROMID® A3 GF 55 8 HU natural (8125) AKROMID® A3 GF 60 8 HU natural (8126) AKROMID® A3 GF 25 8 HU black (8118) AKROMID® A3 GF 30 8 HU black (8112) AKROMID® A3 GF 33 8 HU black (8129) AKROMID® A3 GF 35 8 HU black (8113) AKROMID® A3 GF 40 8 HU black (8114) AKROMID® A3 GF 43 8 HU black (8131) AKROMID® A3 GF 45 8 HU black (8115) AKROMID® A3 GF 50 8 HU black (8116) AKROMID® A3 GF 55 8 HU black (8119) AKROMID® A3 GF 60 8 HU black (8117) Natural (appears white) and black coloured, injection moulded, glass fibre reinforced PA66 materials. For use with water up to 85°C.
'POLYNT 1349 TAEQ20 to be used in conjunction with POLYCOR LP PA FC CLEAR 0200'. POLYNT 1349 TAEQ20 is a polyester resin and LP PA FC CLEAR 0200 is a factory applied, gel coat (when used together the material appears light pink in colour). Apply as per manufacturer's TDS ‘7206 updated 10.10.17’. Cure for 24 hours@25°C. For use with water up to 23°C. This material is only approved for the curing conditions that appear on the approval. If the cure conditions are varied from those specified on the approval then the material is not covered by the scope of the approval.
'Dhara HDPE Black Pipe'. Black coloured (with blue outer stripes), extruded HDPE pipe. For use with water up to 65°C.
'Dhara MDPE Blue Pipe'. Blue coloured, extruded MDPE pipe. For use with water up to 65°C.
'LSPE-BE002 PE Pipe (Deep Blue)'. Blue coloured, extruded polyethylene pipe. For use with water up to 60°C.
'LSPE-BE002 PE Fitting (Deep Blue)'. Blue coloured, injection moulded polyethylene fitting. For use with water up to 60°C.
'LSPE-BK001'. Black coloured, extruded polyethylene pipe. For use with water up to 60°C.
'LSPE-BK001'. Black coloured, injection moulded polyethylene fitting. For use with water up to 60°C.
'ajpipe HDPE Pipe'. Black coloured (with blue external stripes), extruded PE100 pipe. For use with water up to 50°C. From January 2024 the pipe is for use with water up to 60°C.
'100 US Gallon Dubai Polytank Panel'. Triple layered, rotationally moulded LLDPE tank panel comprising of a white coloured inner layer, black coloured middle layer and white coloured outer layer. For use with water up to 65°C.
'Radius Systems Socket Fittings and Saddle Fittings'. Black coloured, injection moulded PE fittings. For use with water up to 60°C.
'HTP-5056 Hexagonal Tube Settler'. Pale blue coloured, extruded polypropylene 'tube settler' component. For use with water up to 23°C.
'3P-PIPE Green PPR Pipe'. Green coloured, extruded PPR pipe. For use with water up to 65°C.
'Classic-Chromline UK Multilayer hose'. Extruded, hose which appears silver and comprises of a cream coloured PVC inner layer, white coloured polyester filament layer, black coloured PVC layer, silver coloured acrylic layer and a transparent PVC outer layer. For use with water up to 60°C.
'Dubai Polymer UPVC Pipes HP2CLASSe'. Grey coloured, extruded UPVC pipe. For use with water up to 65°C.
`Butyl Liner 72612`. Black coloured, calendared butyl rubber sheet material. Shore hardness 60. Tested in-radius size 0.5mm. For use with water up to 23°C.
'EP10/7/7 BLK gaskets & 'O' rings'. Injection moulded, black coloured EPDM gaskets & 'O' rings. Shore hardness 70. The gaskets have an in-radius size of 0.75mm and for use with water up to 85°C. The ‘O’ rings have an in-radius size of 1.5mm and between 1st July 2021 and 21st September 2021, the ‘O’ rings were for use with water up to 23°C. Between 22nd September 2021 and 28th February 2026, the ‘O’ rings are for use with water up to 85°C.
'EUW-70'. Black coloured, injection moulded EPDM diaphragm. Shore hardness 70. Tested in-radius size 0.95mm. For use with water up to 60°C.
'60EP124p'. Black coloured, compression moulded EPDM 'O' rings. Shore hardness 60. Tested in-radius size 1.5mm. For use with water up to 85°C.
'EP6008'. Black coloured, compression moulded EPDM 'O' rings. Shore hardness 60. Tested in-radius size 0.8mm. For use with water up to 85°C.
`EP11/01/13 BLK 'O' rings & seals`. Black coloured, injection moulded 'O' rings & seals. Shore hardness 60. The 'O' rings have a tested in-radius size of 1.8mm. The seals have a tested in-radius size of 0.75mm. For use with water up to 85°C.
'EP60-WAUK-FR'. Black coloured, compression moulded EPDM sheet material. Shore hardness 60. In-radius size 1.35mm. For use with water up to 23°C.
'EP210107'. Black coloured, compression moulded EPDM material. Shore hardness 70. Tested in-radius size 1.0mm. For use with water up to 65°C.
'OYRTEP7011PWRC'. Black coloured, compression moulded EPDM material. Shore hardness 70. Tested in-radius size 1.5mm. For use with water up to 65°C.
'Unecol Sellador Roscas Metalicas'. Yellow coloured, anaerobic adhesive. Apply as per manufacturer's instructions "Technical Datasheet WS27 - Issue 1 30-6-17". For use with water up to 85°C. This product is to be applied and cured in strict accordance with the manufacturer's instructions.
'Durethan BKV30F 901510 SR1'. Black coloured, injection moulded thermoplastic resin. For use with water up to 65°C.
'THERMOLAST K TF5WHA, TF6WHB, TF6WHA, TF7WHB, TF7WHA, TF8WHB & TF8WHA'. Injection moulded, natural (appears off-white translucent) TPE materials with a shore hardness of between 55 and 85. Tested in-radius size 1.0mm. The materials may be coloured using one, or any combination of, the following Kraiburg pigments (up to and including the maximum level included): Black (maximum level 3%). White (maximum level 2%). Blue (maximum level 2%). Orange (maximum level 2%). Yellow 1 (maximum level 2%). Yellow 2 (maximum level 2%). Yellow 3 (maximum level 2%). Green (maximum level 2%). Red 1 (maximum level 2%). Red 2 (maximum level 2%). Brown (maximum level 2%). For use with water up to 65°C.
Range of single hole, single outlet (swivel) combination tap assemblies (various finishes) with a pull-out spray mechanism. Flow is controlled via a ceramic cartridge headwork with a single lever operating member incorporating an infra-red sensor on the swivel arm which operates a solenoid valve. The spout outlet incorporates a plastic aerator and a hand spray mechanism, and the product is supplied with metal backnuts. Maximum working pressure 5.0 Bar. Maximum operating temperature 60°C.
Side entry BS1212-4 (2016) compact type float operated valve for WC flushing cisterns. The inlet incorporates a flow restrictor. Maximum working pressure 10.0 bar. Cold water use only.
Side entry BS1212-4 (2016) compact type float operated valve for WC flushing cisterns. The inlet incorporates a flow restrictor. Maximum working pressure 10.0 bar. Cold water use only.
Side entry BS1212-4 (2016) compact type float operated valve for WC flushing cisterns. The inlet incorporates a flow restrictor. Maximum working pressure 10.0 bar. Cold water use only.
Range of BS1212-4 diaphragm type inlet valves incorporating a plastic body for use in either side or bottom entry WC cisterns. The valves incorporate an up and over discharge, plastic arm and float. The inlet is fitted with a plastic flow regulator and strainer. Maximum working pressure 10 bar. Cold water use only.
Spring loaded resilient trim, in-line check valve cartridge with plastic guides and stem and NBR seals within a plastic housing. For insertion into pipes or fittings with specifically dimensioned bores. Maximum working pressure 16.0 bar & maximum operating temperature 65°C.
Spring loaded resilient trim, in-line check valve cartridges incorporating plastic guides and stem, NBR or EPDM seals within a plastic housing. For insertion into pipes or fittings with specifically dimensioned bores. Maximum working pressure 16.0 Bar. Maximum operating temperature 65°C.
Range of single check valve cartridges incorporating a plastic body, stainless steel spring, NBR or EPDM seals. Maximum working pressure 16.0 bar. Maximum operating temperature 65°C.
Spring loaded resilient trim, in-line check valve cartridge with plastic guides and stem and silicone seals within a plastic housing. For insertion into pipes or fittings with specifically dimensioned bores. Maximum working pressure 16.0 bar Maximum operating temperature 65°C.
Robocheck-1 in-line single check valve assembly with a DZR brass body (brushed chrome). Maximum working pressure 16.0 bar. Maximum operating temperature 85°C.
Single hole bidet tap with brass body (various finishes) fixed spout outlet and a ceramic disc headwork (various operating members). The outlet incorporates an aerator and the product is supplied with a pop-up waste. Maximum working pressure 3.5 bar. Maximum operating temperature 60°C.
Single hole, single outlet (swivel), combination tap assembly (chromium plated brass) incorporating a ceramic cartridge headwork with single lever operating member. The product incorporates a pull-out spout outlet with a plastic aerator. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.
Range of wall mounted, two hole, single outlet (swivel) combination tap assemblies (chromium plated brass), incorporating a quarter turn ceramic disk headwork with a single lever operating member. The product incorporates a hand held pre-rinse spray with a self-closing trigger on a flexible hose within an overhead spring. Models are available with an additional swivel spout outlet, which incorporates a plastic aerator (see model). The swivel spouts have their own flow control in addition to the main headwork, this is also a quarter turn ceramic disk headwork with a single lever operating member. The inlets incorporate an approved check valve cartridge, however the complete product has not been fully tested to demonstrate it provides backflow protection. The product is supplied with metal backnuts. Maximum working pressure 8.62 bar. Maximum operating temperature 60°C.
Range of wall mounted, two hole, single outlet (swivel) combination tap assemblies (chromium plated brass), incorporating quarter turn ceramic disk headworks with single lever operating members. The product incorporates a hand held pre-rinse spray with a self-closing trigger, either on a flexible hose within an overhead spring or as a fixed length flexible hose on a swivel arm (see model). Models are available with an additional swivel spout outlet, which incorporates a plastic aerator (see model). The swivel spouts have their own flow control in addition to the main headwork, this is also a quarter turn ceramic disk headwork with a single lever operating member. Each inlet incorporates an approved check valve cartridge however, the complete product has not been fully tested to demonstrate it provides backflow protection. The product is supplied with metal backnuts. Maximum working pressure 8.62 bar. Maximum operating temperature 60°C.
Range of deck mounted, single hole, single outlet (swivel) combination tap assemblies (chromium plated brass), incorporating a quarter turn ceramic disk headwork with a single lever operating member. The product incorporates a hand held pre-rinse spray with a self-closing trigger, either on a flexible hose within an overhead spring or as a fixed length flexible hose on a swivel arm (see model). Models are available with an additional swivel spout outlet, which incorporates a plastic aerator (see model). The swivel spouts have their own flow control in addition to the main headwork, this is also a quarter turn ceramic disk headwork with a single lever operating member. The product is supplied with metal backnuts. UK-1DPXX models only are a single feed and come with an optional ½” NPSM (M) x ½” BSP (F) brass adapter. Maximum working pressure 8.62 bar. Maximum operating temperature 60°C.
Range of single hole, single outlet fixed combination tap assemblies (chrome plated brass), incorporating a ceramic cartridge headwork with a single lever operating member. Model BTZ 1HF C incorporates a plastic flow straightener. Model BTZ SMBAS C incorporates a plastic aerator. Maximum operating pressure 5.0 bar. Maximum operating temperature 60°C
Range of single hole, single outlet (fixed) combination tap assemblies with brass bodies (various finishes) incorporating ceramic cartridge headworks and single lever operating members. The spout outlets incorporate a plastic aerator. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.
Range of single hole, single outlet (fixed) combination tap assemblies (chromium plated brass), incorporating a ceramic cartridge headwork with a single lever operating member. The spout outlet incorporates a plastic aerator. Maximum working pressure 8.0 bar. Maximum operating temperature 60°C.
Single hole, single outlet (fixed) combination tap assembly (chromium plated brass). Incorporating ceramic cartridge headworks, and single lever operating members. The spout outlet incorporates a plastic aerator and the product is supplied with a pop up waste. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.
Range of single hole, single outlet (fixed) combination tap assemblies with brass bodies (various finishes - see model), incorporating ceramic a cartridge headwork with a single lever operating member. The spout outlets incorporate a plastic aerator. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.
Single hole, single outlet (fixed) combination tap assembly with a brushed stainless-steel body, incorporating a ceramic cartridge headwork with a single lever operating member. The spout outlet incorporates a plastic aerator. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.
Range of single-hole, single outlet (fixed) combination tap assemblies with brass bodies (various finishes), incorporating a ceramic cartridge headwork with a single lever operating member. The spout outlet incorporates a plastic aerator. Some models are supplied with click type or pop-up wastes. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.
Range of single hole, single outlet (fixed) combination tap assemblies (brass bodies - various finishes), incorporating a ceramic cartridge headwork with a single lever operating member. The spout outlet incorporates a plastic aerator. The 36 110 000 model is supplied with a pop-up waste. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.
Single hole, single outlet (fixed) combination tap assembly (chromium plated brass), incorporating quarter turn ceramic disc headworks with cross top operating members. The spout outlet incorporates a plastic aerator. The product is supplied with a pop-up waste. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.
Range of single hole, single outlet (fixed) combination tap assemblies (chromium plated brass), incorporating a ceramic cartridge headwork with a single lever operating member. The products are supplied with a brass ⅜” BSP (M) x 15mm compression adapter. The spout outlets incorporate a plastic aerator. The A6259AA model is supplied with pop-up waste. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.
Range of single hole, single outlet (swivel) combination tap assemblies with brass bodies (various finishes). Incorporating ceramic cartridge headworks and single lever operating member. The spout outlet incorporates a plastic aerator. Maximum working pressure 5.5 bar. Maximum operating temperature 60°C.
Single hole, single outlet (swivel) combination tap assembly with brass body (chrom plated). Incorporating quarter turn ceramic disc headworks and single lever operating members. The spout outlet incorporates a plastic aerator. Maximum working pressure 5.5 bar. Maximum operating temperature 60°C.
Range of single hole, single outlet (swivel) combination tap assemblies (chrome plated brass), incorporating ceramic disc headworks with single lever operating members. The spout outlet incorporates a plastic flow straightener. The product is supplied with single check valves with integral servicing valve for both inlets (suitable for backflow protection against Fluid Category 2). Maximum working pressure 10.0 bar. Maximum operating temperature 60°C
Range of single hole, single outlet (swivel) combination tap assemblies (chrome plated brass), incorporating a ceramic cartridge headwork with a single lever operating member. The spout outlet incorporates a plastic aerator. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C
Range of single hole single outlet (swivel) combination tap assmeblies with quarter turn ceramic disc headworks and single lever operating members. The outlet incorporates a plastic aerator. Maximum working pressure 5.5 bar. Maximum operating temperature 60°C.
Range of single hole, single outlet (swivel) combination tap assemblies (chromium plated brass) incorporating a ceramic cartridge headwork with a single lever operating member. The spout outlet incorporates a plastic aerator. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.
Single hole, single outlet (swivel) combination tap assembly (chromium plated brass), incorporating a ceramic cartridge headwork with a single lever operating member. The spout outlet incorporates a plastic aerator. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.
Range of single hole, single outlet (swivel) combination tap assemblies with brass bodies (various finishes), incorporating quarter turn ceramic disc headworks with either single lever or cross top operating members. The spout outlet incorporates a plastic flow straightener. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.
Single hole, single outlet (swivel), combination tap assembly (chromium plated brass), incorporating a ceramic cartridge headwork with a single lever operating member. The spout outlet incorporates a plastic aerator. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.
Range of single hole, metal, single outlet (swivel) also with end swivel spout, combination tap assembly (brass or stainless steel body - various finishes), incorporating a ceramic cartridge headwork with a single lever operating member. The spout outlet incorporates a plastic aerator. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.
Range of single hole, metal, single outlet (swivel) also with end swivel spout, combination tap assembly (brass or stainless steel body - various finishes), incorporating a ceramic cartridge headwork with a single lever operating member. The spout outlet incorporates a plastic aerator. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.
Range of single hole, metal, single outlet (swivel) combination tap assemblies (brass body - various finishes) incorporating quarter turn ceramic disc headworks with single lever operating members. The spout outlets incorporate a plastic aerator. The VOLA KV6 and VOLA KV7 models also have an end swivel spout. The VOLA HV7 and VOLA KV7 models are supplied with a pop-up waste. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.
Range of single-hole, single outlet (swivel) combination tap assemblies (brass bodies - various finishes - see model), incorporating a ceramic cartridge headwork with a single lever operating member. The spout outlet incorporates a plastic aerator. Maximum working pressure 10.0 bar. Maximum working temperature 60°C.
Two hole, single outlet fixed combination tap assembly (chrome plated brass) incorporating ¼ turn ceramic disc headworks with single lever operating members. The spout outlet incorporates a plastic flow straightener. This product is supplied with metal backnuts. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.
Range of wall mounted, two hole, single outlet (fixed) combination tap assemblies (chromium plated brass or stainless steel - INOX models), comprising of a concealed rough in set with a brass body and a variety of separate trim sets incorporating a ceramic cartridge headwork with a dome type or single lever operating member and a spout outlet. The spout outlet incorporates a plastic aerator. The products are supplied with click type (click clack) waste. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.
Wall mounted, two hole, single outlet (fixed) combination tap assembly (chromium plated brass), incorporating a ceramic cartridge headwork with a single lever operating member. The spout outlet incorporates a plastic aerator. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.
Range of two hole, single outlet (fixed) combination tap assemblies (chromium plated brass), incorporating quarter turn ceramic disc headworks with single lever operating members. The spout outlet incorporates a plastic flow straightener. The products are supplied with metal back nuts. Maximum working pressure 5.0 bar. Maximum working temperature 60°C.
Range of two hole, single outlet (fixed) combination tap assemblies (chromium plated brass), incorporating quarter turn ceramic disc headworks with single lever operating members. The spout outlet incorporates a plastic flow straightener. The products are supplied with plastic back nuts. Maximum working pressure 5.0 bar. Maximum working temperature 60°C. A two hole single outlet (fixed) combination tap assembly with brass body (chromium plated). Incorporating a quarter turn ceramic disc headworks with a single lever operating member. The outlet incorporates a plastic flow straightener. This product is supplied with plastic back nuts. Maximum working pressure 5.0 bar. Maximum working temperature 60°C.
Range of two-hole, single outlet (fixed) combination tap assemblies (chrome plated brass), incorporating quarter turn ceramic disc headworks with single lever operating members. The spout outlet incorporates a plastic flow straightener. The product is supplied with metal backnuts. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.
Range of wall mounted, two-hole, single outlet (fixed) combination tap assemblies, comprising of a concealed rough in set with a brass body and a variety of separate trim sets incorporating a ceramic cartridge headwork with a single lever operating member and a spout outlet. The spout outlet incorporates a plastic aerator. Maximum working pressure 10.0 Bar. Maximum operating temperature 85°C.
Range of wall mounted two hole, metal, single outlet (fixed) combination tap assemblies (chromium plated brass), incorporating a 2 way ceramic disc diverter controlling the flow between the spout outlet and the shower outlets with a dome type operating member. Temperature is controlled independently via a thermostatic cartridge with a dome type operating member which incorporates a manual override button. The product incorporates a secondary manual diverter to divert the flow between the overhead shower and the shower hose and handset. The spout outlet incorporates a plastic aerator. The inlets and the outlet to the shower handset all incorporate an approved check valve cartridge, however, the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C
Deck mounted, two-hole, single outlet (fixed) combination tap assembly (chrome plated brass) incorporating a manual diverter to shower with a single lever operating member. Flow is controlled via a ½ turn ceramic disc headworks with cross top operating members. Maximum working pressure 5.0 bar. Maximum operating temperature 60ºC
Wall mounted, exposed, two-hole single outlet, fixed, combination tap assemblies (brass body – various finishes) incorporating two ‘detent’ (push to on push to off) headworks, one controlling the flow to the bath outlet and the other to the shower outlet. The temperature is controlled independently via a thermostatic cartridge with a single lever operating member incorporating a manual override button. Both inlets and the shower outlet incorporate an approved check valve cartridge, however the complete product has not been fully tested to demonstrate it provides backflow protection. The inlets also incorporate a stainless-steel strainer. The spout outlet incorporates a plastic aerator. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.
Range of two-hole, single outlet (swivel) combination tap assemblies (chromium plated brass), incorporating quarter turn ceramic disc headworks with various operating members (see model). The spout outlets of the SH-T80541 & SH-T80542 models incorporate a plastic flow straightener, all other models incorporate a plastic aerator. The products are supplied with plastic backnuts. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.
Two hole, single outlet (swivel) combination tap assembly (chromium plated brass), incorporating a ceramic cartridge headwork with a single lever operating member. The spout outlet incorporates a plastic aerator. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.
Range of two-hole, single outlet (swivel) combination tap assemblies (brass body - various finishes), incorporating quarter turn ceramic disc headworks with either single lever or wheel operating members. The spout outlet incorporates a plastic aerator. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C
Two-hole, single outlet fixed combination tap assembly (chromium plated brass) incorporating quarter turn ceramic disc headworks with single lever operating members and a lockable self-cancelling diverter to shower outlet. The spout outlet incorporates a plastic flow straightener The product is supplied with a shower hose and handset and metal backnuts. Maximum working pressure 10.0 bar. Maximum working temperature 60°C.
Two-hole, single outlet fixed combination tap assembly (chromium plated brass) incorporating quarter turn ceramic disc headworks with single lever operating members and a lockable self-cancelling diverter to shower outlet. The spout outlet incorporates a plastic flow straightener The product is supplied with a shower hose and handset and metal backnuts. Maximum working pressure 10.0 bar. Maximum working temperature 60°C.
Two-hole, single outlet fixed combination tap assembly (chromium plated brass) incorporating quarter turn ceramic disc headworks with single lever operating members and a lockable self-cancelling diverter to shower outlet. The spout outlet incorporates a plastic flow straightener The product is supplied with a shower hose and handset and metal backnuts. Maximum working pressure 10.0 bar. Maximum working temperature 60°C.
Range of two hole, single outlet (fixed) combination tap assemblies with brass bodies (various finishes - see model), incorporating quarter turn ceramic disc headworks with single lever operating members and a locakble self-cancelling diverter to shower outlet. The spout outlets incorporate a plastic aerator. The product is supplied with a shower hose and handset and metal backnuts Maximum working pressure 5.0 bar. Maximum working temperature 60°C.
Range of wall mounted three hole, single outlet (fixed) combination tap assemblies with brass bodies (in various finishes). Incorporating quarter turn ceramic disc headworks and various operating members. The spout outlet incorporates a plastic aerator. Maximum working pressure 3.5 bar. Maximum operating temperature 60°C.
Range of three hole, single outlet (fixed) combination tap assemblies with brass bodies (various finishes - see model), incorporating quarter turn ceramic disc headworks with various operating members (see model). The products are supplied with stainless steel braided EDPM lined flexible hose assemblies incorporating ¾” captive nut end connections for installation between the headworks and the spout. The spout outlet incorporates either a plastic flow straightener or plastic aerator (see model). The invincible range is supplied with a plastic back nut, all other models are supplied with metal back nuts. Maximum working pressure 3.0 bar. Maximum working temperature 60°C.
Three hole, single outlet (fixed) combination tap assembly with a brass body (various finishes - see model), incorporating quarter turn ceramic disc headworks with dome type operating members. The products are supplied with stainless steel braided EDPM lined flexible hose assemblies incorporating ¾” captive nut end connections for installation between the headworks and the spout. The spout outlet incorporates a plastic aerator. The product is supplied with metal back nuts. Maximum working pressure 3.0 bar. Maximum working temperature 60°C.
Range of three-hole, single outlet (swivel) combination tap assembly (chromium plated brass), incorporating quarter turn ceramic disc headworks with single lever (20815882 model) or cross top (20815892 model) operating members. The product is supplied with stainless steel braided PEX lined flexible hose assemblies for installation between the side valves and the spout. The spout outlets incorporate a plastic aerator. The side valves are supplied with plastic backnuts. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.
Three hole, wall mounted, concealed basin mixer with a brass body (chrome plated) consisting of a rough in set 45089 and extermnal trim 46090. Incorproating a quarter turn ceramic disc headworks and single lever operating members.The spout outlet incorporates a plastic aerator. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.
Bath spout outlet with a brass body (various finishes) and a plastic aerator. Maximum operating temperature 60°C.
Range of deck mounted spout outlets (chrome plated brass). The spout incorporates a plastic flow regulator on the inlet and a plastic aerator on the outlet. Maximum working temperature 60°C.
Range of expansion vessels incorporating composite plastic bodies and butyl diaphragms. Maximum working pressure 8.6 bar. Cold water use only.
Filling link assembly, incorporating a sliding manifold with EPDM ‘O’-rings, isolation valves and an isolation valve with a double check valve assembly (verified by test as suitable for backflow protection against Fluid Category 3). Maximum working pressure 10.0 bar. Cold water use only.
Water filter with polypropylene body. Maximum working pressure 8.6 bar. Cold water use only.
Range of brass compression fittings for use with copper pipe IS EN 1057. Maximum working pressure 10.0 bar. Maximum operating temperature 99°C.
Range of press fittings incorporating brass or PVDF bodies and EPDM ‘O’-rings. For use with Henco standard PE-Xc/AL/PE-Xc pipe. Maximum working pressure 10.0 bar. Maximum operating temperature 95°C.
Range of press fittings incorporating stainless steel bodies and EPDM ‘O’-rings. Maximum working pressure 16.0 bar. Maximum operating temperature 85°C.
Range of SUS316L & SUS304 stainless steel press fittings for use with stainless steel pipe manufactured to EN 10312. Maximum working pressure 16.0 bar. Maximum operating temperature 85°C.
Range of WC dual flush drop valves comprising of a plastic body, silicone seal and an internal overflow. The valve is operated via a push button or lever assembly for either full or reduced flush. Cold water use only.
Range of wastewater heat recovery systems incorporating a double wall stainless steel corrugated pipe. Maximum working pressure 16.0 bar. Cold water use only.
Range of wastewater heat recovery systems incorporating stainless steel corrugated pipe. Maximum working pressure 16.0 bar. Cold water use only.
Range of vertical vented cased copper cylinders with indirect coils. The secondary circuit incorporates a thermostatic mixing valve. The inlet consists of a ball valve with strainer, inline non verifiable single check valve and mini shock arrestor. Cylinder are supplied with a factory fitted immersion heater. Maximum working pressure - secondary 6.0 bar, primary 2.2 bar. Maximum operating temperature - secondary is 60°C, primary 85°C
‘E-WATER BLOCK’ self-closing valves with black plastic bodies and stainless-steel filters. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.
Appliance inlet group assembly comprising of EPDM gaskets, a plastic bodied Y-pattern strainer, ¾” BSP (F) x ½” BSP (F) brass adaptor, a chrome plated DZR brass bodied double check valve assembly (suitable for backflow protection against Fluid Categry3), a ½” BSP (F) x ¾” BSP (M) brass adaptor, a dual layer hose with a PVC outer (grey) and PVC liner (black), a solenoid valve which incorporates a plastic strainer and a flow regulator within the inlet. Maximum working pressure 6.0 bar. Maximum operating temperature 60°C.
Range of cast iron (blue epoxy coated) (G versions only) or stainless steel (all other versions - F, N, R, T) vertical multistage pumps with stainless steel impellers, shaft and outer sleeve and EPDM 'O'-rings and seals. The pumps incorporate a ceramic/carbon graphite/EPDM and stainless steel mechanical shaft seal (QBEGG). Maximum working pressures: 1-22SV models: 1SV27-1SV37 (F VERSION) - PN16 (25mm). 3SV23-3SV33 (F VERSION) - PN16 (25mm). 5SV23-5SV33 (F VERSION) - PN16 (32mm). 10SV27-10SV21 (F VERSION) - PN16 (40mm). 15SV11-15SV17 (F VERSION) - PN16 (50mm). 22SV12-22SV17 (F VERSION) - PN16 (50mm). 1SV02-1SV25 (F VERSION) - PN25 (25mm). 3SV02-3SV21 (F VERSION) - PN25 (25mm). 5SV02-5SV16 (F VERSION) - PN25 (32mm). 10SV01-10SV13 (F VERSION) - PN25 (40mm). 15SV01-15SV10 (F VERSION) - PN25 (50mm). 22SV01-22SV10 (F VERSION) - PN25 (50mm). N VERSIONS ALL MODELS - PN25 (25-50mm). R VERSION ALL MODELS - PN25 (25-50mm). T VERSION ALL MODELS - PN16 (25-50mm). 33-125SV models: 33SV1-33SV5, 33SV6/2AG150T/D & 33SV6/2AN150T/D (G or N VERSION) - PN16 (65mm). 46SV1-46SV5 (G or N VERSION) - PN16 (80mm). 66SV1-66SV5 (G or N VERSION) - PN16 (100mm). 92SV1-92SV4 (G or N VERSION) - PN16 (100mm). 125SV1-125SV6 (G VERSION) - PN16 (125mm). 33SV7-33SV10, 33SV6/1AG150T/D, 33SV6/1AN150T/D, 33SV6G150T/D & 33SV6N150T/D (G VERSION) - PN25, (N VERSION) - PN16 (65mm). 46SV6-46SV9 (G VERSION) - PN25, (N VERSION) - PN16 (80mm). 66SV6-66SV8 (G VERSION) - PN25, (N VERSION) - PN16 (100mm). 92SV5-92SV7 (G VERSION) - PN25, (N VERSION) - PN16 (100mm). 125SV7-125SV8 (G VERSION) - PN25 (125mm). 33SV10-33SV13 (G VERSION) - PN40 (65mm). 46SV10-46SV13 (G VERSION) - PN40 (80mm). Cold water use only. VERSION) - PN25 (100mm). 92SV5-92SV7 (G or N VERSION) - PN25 (100mm). 125SV7-125SV8 (G or N VERSION) - PN25 (125mm). 33SV10-33SV13 (G VERSION) - PN40 (65mm). 46SV10-46SV13 (G VERSION) - PN40 (80mm). Cold water use only.
Range of booster pumps with stainless steel bodies and impellers (AISI 304: AL-RED models or AISI 316: CP models), EPDM ‘O’-rings and a ceramic/graphite/EPDM shaft seal. Maximum working pressure: CP(m) 100-130-132-150-158 and AL-RED(m) 600-610-620 models: 6.0 bar. All other models: 8.0 bar. Maximum operating temperature 90°C.
Range of shower heads and a shower handset. The shower heads have a stainless steel body and ball joint, silicon ‘O’-rings and nozzles, and the inlet incorporates a combined NBR washer and stainless steel filter. The shower handset has a stainless steel body, NBR ‘O’-rings and silicon nozzles. All products incorporate a plastic flow regulator on the inlet. Maximum operating temperature 60°C.
Range of wall mounted or ceiling mounted shower arms with brass bodies (various finishes) Maximum operating temperature 90°C.
Handshower with a chrome plated plastic body. The inlet incorporates a single check valve cartridge, however, the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum operating temperature 60°C.
Range of wall or ceiling mounted shower arms and a wall mounted shower outlet + holder. The products incorporate a stainless steel bodies (various finishes). Maximum operating temperature 60°C.
Dolphin Blue Flexi hose range of wall outlets and brackets incorporating stainless steel bodies (various finishes) and EPDM ‘O’-rings. Maximum operating temperature 85°C
Dolphin Blue range of handheld shower outlets with a stainless bodies (various finishes) and EPDM ‘O’-rings. The inlet incorporates a single check valve cartridge however, the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum operating temperature 85°C
Range of wall mounted shower elbows with brass bodies (chrome plated) incorporating single check valves cartridges fitted on the outlet (however, the complete product has not been fully tested to demonstrate it provides backflow protection).Maximum operating temperature 65°C.
Range of shower outlets with brass or stainless steel bodies (chrome plated) fitted with NBR ’O’-rings. Maximum operating temperature 65°C.
Range of shower arms with a brass body and various finishes. Maximum operating temperature 60°C.
Range of shower handsets with plastic bodies and EPDM ‘O’-rings. Maximum operating temperature 65°C.
Range of wall mounted compact shower panels with push button timed flow control. The inlet incorporates a plastic flow regulator and a stainless-steel strainer. Maximum working pressure 4.0 Bar Maximum operating temperature 60°C
Concealed installation set for use with wall mounted overhead shower outlets (brass body – various finishes). The inlet to the shower outlet incorporates a stainless-steel strainer, a plastic flow regulator and an approved check valve cartridge, however, the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum operating temperature 60°C.
Range of shower hoses and handsets (various finishes - see model) with EPDM ‘O’-rings. Maximum operating temperature 60°C.
Range of Y pattern strainers incorporating blue epoxy coated ductile iron bodies and stainless steel mesh filter. With PN16 flanges to BS EN 1092-2. Maximum working pressure 16.0 bar. Cold water use only.
Range of bib taps with DZR brass bodies. The inlet and the outlet of the tap incorporates approved single check valve cartridges however, the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum working pressure 16.0 bar. Maximum operating temperature 85°C.
Bib tap incorporating brass bodies. The inlet and the outlet of the tap incorporates approved single check valve cartridges however, the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum working pressure 16.0 bar. Maximum operating temperature 85°C.
Range of wall mounted hose union tap brass body incorporating a non-rising spindle headwork with a butterfly handle operating member. Maximum working pressure 16.0 bar. Maximum operating temperature 85°C.
Range of wall mounted hose union taps brass body incorporating a non-rising spindle headwork with a butterfly handle operating member. Maximum working pressure 16.0 bar. Maximum operating temperature 85°C.
Range of pillar taps (chrome plated brass) with quarter turn ceramic disc headworks and single lever operating members. The spout outlet incorporates a plastic flow straightener. The product is supplied with metal backnuts. Maximum working pressure 10.0 Bar Maximum operating temperature 60°C.
Range of pillar taps (chromium plated brass) incorporating quarter turn ceramic disc headworks with single lever or cross top operating members. The spout outlets incorporate a plastic aerator (AX-IRO-106-CP, AX-MET-106-CP & AX-MET-1369-CP models only) or a plastic flow straightener (AX-IRO-136-CP model only). The products are supplied with metal backnuts. Maximum working pressure 5.0 bar. Maximum operating pressure 60°C.
Pillar taps (chromium plated brass) incorporating quarter turn ceramic disc headwork with single lever or cross top operating members. The spout outlets incorporate a plastic aerator or flow straightener. The product is supplied with metal backnuts. Maximum working pressure 5.0 bar. Maximum operating pressure 60°C.
Pillar tap incorporating a ceramic cartridge headwork (chrome plated brass body) with a single lever operating member. The spout outlet incorporates a flow straightener and flow regulator. The product is supplied with plastic backnuts Maximum working pressure 10 bar. Maximum operating temperature 60°C
Range of pillar taps with brass bodies (various finishes - see model) incorporating quarter turn ceramic disc headworks with single lever operating members. The spout outlet incorporates a plastic flow straightener. The 4102BD18 models incorporate a plastic flow restrictor on the inlet. The products are supplied with plastic and brass backnuts. Maximum working pressure 10.0 bar. Maximum operating temperature 65°C.
Range of pillar taps with brass bodies (various finishes), incorporating quarter turn ceramic disc headworks with either cross top or single lever operating members. The spout outlet incorporates a plastic flow straightener. The product is supplied with metal backnuts. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.
Range of pillar taps (chromium plated brass), incorporating quarter turn ceramic disc headworks with single lever, dome type or cross top operating members and plastic backnuts. The spout outlets incorporate a plastic flow straightener. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.
Range of pillar taps (chromium plated brass), incorporating quarter turn ceramic disc headworks with single lever, dome type or cross top operating members and plastic backnuts. The spout outlets incorporate a plastic flow straightener. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.
Range of self-closing tap assemblies (chrome plated brass) with spring loaded headworks and dome type or single lever (745440 model only) operating members. The spout outlet incorporates a plastic flow straightener. The product is supplied with plastic backnuts. Maximum working pressure 5.0 Bar. Maximum operating temperature 60°C.
Range of wall mounted, self-closing tap assemblies (chrome plated brass) with spring loaded headwork and dome type operating members. The spout outlet incorporates a plastic flow straightener. Maximum working pressure 5.0 Bar. Maximum operating temperature 60°C.
Range of shower hoses incorporating a PVC inner liner & EPDM washers. Maximum operating temperature 60°C.
Range of chromium plated brass interlocked shower hoses incorporating either a PVC or TPE inner hose and EPDM gaskets. Maximum operating temperature 60°C.
Range of chromium plated brass interlocked shower hoses incorporating either a PVC or TPE inner hose and EPDM gaskets. Maximum operating temperature 60°C.
Range of stainless-steel interlocked shower hoses (various finishes) incorporating a PVC liner and EPDM gaskets. Maximum operating temperature 65°C.
UWILL range of PVC and PEX lined shower hoses (model UW-MS1003 is PEX lined), (models UW-MS1003 and UW-MS1005) incorporate corrugated interlocking metal hoses with various finishes. All hoses incorporate EPDM washers. Maximum operating temperature 65°C.
Range of stainless steel and ACB braided hoses with and EPDM liner and various end connections. Maximum working pressure 10.0 bar. Maximum operating temperature 85ºC. Hoses with plastic push fittings: maximum working pressure 6.0 bar. Maximum operating temperature 65ºC.
Range of shower hoses incorporating NBR gaskets, either EPDM or PVC liners and stainless steel interlocked casing . Maximum operating temperature 60°C.
Shower hose incorporating a stainless steel interlocked casing and PVC liner. Supplied with NBR gaskets. Maximum operating temperature 65°C.
Range of air release valves with blue epoxy coated ductile iron bodies and EPDM seals. Maximum working pressure 16.0 bar. Maximum operating temperature 65°C.
Range of deck mounted, concealed, manually operated blending valves with brass bodies or stainless-steel bodies (various finishes), incorporating a ceramic cartridge headwork with a single lever operating member. Maximum working pressure 5.0 bar. Maximum operating temperature 70°C.
Range of wall mounted thermostatic blending valves with brass bodies (various finishes). Incorporating quarter turn ceramic disc headworks and single lever operating member. The temperature is controlled independently via a thermostatic cartridge, single lever operating member and a manual override button. Inlets incorporate a strainer and single check valve cartridges however the complete assembly has not been tested to verify it provides backflow protection. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.
Flow control valve incorporating a ceramic cartridge headwork fitted within a chrome plated brass body and a single lever operating member. Product is supplied with a Stainless steel braided PEX lined hose assembly that connects to the outlet. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.
Range of wall mounted thermostatic shower valves with brass bodies (various finishes). Incorporating ceramic disc headwork with a dome type operating member which also divertes the flow between an over head shower and a shower handset. The temperature is controlled independently via a thermostatic cartridge and dome type operating member with a manual override button.The inlets incorporate a single check valve cartridge (however the complete assembly has not been tested to demonstrate it provides adequate backflow protection) and a filter. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C
Range of wall mounted thermostatic shower valves, riser rail, shower handset, shower hose and overhead shower outlet. The valve incorporates a brass body (various finishes) and ceramic disc headwork with dome type operating member which controls and diverts the flow between the two shower outlets. The temperature is controlled independently via a thermostatic cartridge with a dome type operating member incorporating a manual override button. Inlets incorporate stainless steel filters and a single check valve cartridge however the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum working pressure 8.0 bar. Maximum operating temperature 60°C.
Range of wall mounted, exposed, thermostatic bar type shower mixing valves (chromium plated brass). The DC3002 & DC3007 prefix models incorporate a 2-way ceramic disc diverter headwork with dome (DC3001 models) or cubed type (DC3006 & DC3007 models) operating members controlling the flow either shower outlet. The DC3001 model incorporate a ¼ turn ceramic disc headwork with dome (DC3001 & DC3002 models) or cubed type (DC3006 & DC3007 models) operating members controlling the flow to a single shower outlet. The temperature is controlled independently via a thermostatic cartridge. The inlets incorporate stainless steel strainers and approved check valve cartridges however, the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum working pressure 5.0 bar. Maximum operating temperature 80°C.
Wall mounted, thermostatic shower blending valves with brass bodies (enclosed within a white and chrome plated case), incorporating a quarter turn ceramic disc headwork controlling the flow with a dome type operating member. The temperature is controlled independently via a thermostatic cartridge with a dome type operating member which incorporates a manual override button. The product also incorporates three ‘detent’ (push to on push to off) diverters, controlling the flow to the shower handset or overhead shower, (which has two outlet patterns). The product is supplied with a shower riser, overhead shower outlet, shower hose and handset. The inlets incorporate a combined EPDM washer and stainless strainer and an approved check valve cartridge, however, the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum working pressure 8.0 bar. Maximum operating temperature 60°C.
Wall mounted, exposed thermostatic shower valve (chromium plated brass) incorporating a thermostatic cartridge that controls the temperature and a shut off valve that controls the flow both with a single lever operating member. The inlets incorporate stainless steel strainers and an approved check valve cartridge, however, the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum working pressure 8.0 bar. Maximum operating temperature 60°C.
Wall mounted, bar type, thermostatic shower mixer (chromium plated brass), incorporating a ½ turn ceramic disc headwork controlling the flow with a dome type operating member. The temperature is controlled independently via a thermostatic cartridge with a dome type operating member incorporating a manual override button. Both inlets incorporate an approved check valve cartridge, however the complete product has not been fully tested to demonstrate it provides backflow protection. The TR10032CP model is supplied with a riser rail, shower hose and handset. The TR10010CP is the valve only. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.
Range of wall mounted, exposed, thermostatic bar type shower mixing valves (chromium plated brass). The B36264 model incorporates a 2-way ceramic disc diverter headwork with a dome type operating member controlling the flow between an overhead shower outlet and a shower handset. The B38130 model incorporates a quarter turn ceramic disc headwork with a dome type operating member controlling the flow to a shower handset. The temperature is controlled independently via a thermostatic cartridge with a dome type operating member which incorporates a manual override button. Both inlets incorporate a combined EPDM washer and stainless-steel strainer, as well as an approved single check valve cartridge, however, the complete product has not been fully tested to demonstrate it provides backflow protection. Both products are supplied with a shower hose and handset, the B36264 model also includes a shower riser to an overhead shower outlet. Maximum working pressure 8.0 bar. Maximum operating temperature 60°C.
Range of wall mounted, exposed, thermostatic shower blending valves (chromium plated brass) with one or two outlets (see model). Flow is controlled by one or two quarter turn ceramic disc headwork with a single lever operating member. The temperature is controlled independently via a thermostatic cartridge with a.cross top operating member. Each inlet incorporates a check valve cartridge, verified by test (suitable for backflow protection against Fluid Category 2). Maximum working pressure 6.0 bar. Maximum operating temperature 85°C.
Range of wall mounted, concealed, thermostatic shower blending valves with brass bodies and trim sets (various finishes). The temperature is controlled via a thermostatic cartridge with a cross top or single lever operating member. The inlets incorporate an approved check valve cartridge, however the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.
Series 900 range of wafer and lugged type, concentric butterfly valves with orange epoxy coated cast iron bodies, austenitic steel discs and EPDM seats. Maximum working pressure 16.0 bar. Cold water use only.
Range of handwheel operated butterfly valves with blue epoxy coated cast iron bodies and discs, with an EPDM seat (D341X-16Q models) or EPDM sealing ring (D343X-16Q models). Maximum working pressure 16.0 bar. Maximum operating temperature 85°C.
Page 1 of 9
We use cookies to give you the best possible experience with WRAS. Some are essential to provide website functions and ensure the website is secure. We also use cookies to help us understand how people use the site and to make improvements. Click "Accept All" to enable recommended settings or click "Manage cookies" to adjust your settings. For more details, see our Cookie Policy.