Stainless steel bodied sensor with EPDM ‘O’-ring. Maximum operating temperature 90°C.
Range of circulating pumps, with plastic or stainless steel bodies (cast EN 1.4308 or plate EN 1.4301) and a plastic impeller. Maximum working pressure 10.0 bar (stainless steel bodied pumps), 3.0 bar (plastic bodied pumps). Maximum operating temperature 95°C.
Range of single stage circulating pumps with plastic impellers and stainless steel housing, (red external coating - all models, and from July 2023 a yellow external coating on the 1½" model with 130mm port length). From December 2023 the UPS25 prefix models can be supplied with EPDM inlet/outlet gaskets and the UPS32 prefix models can be supplied with fibre/NBR inlet/outlet gaskets. Maximum working pressure 10.0 bar. Maximum operating temperature 95°C (s/steel plate EN 1.4301/1.4401 models) or 99°C (s/steel cast EN 1.4308 models).
Range of single stage centrifugal pumps with bronze housings or plastic housings (see model) and plastic impellers. Maximum working pressure 6.0 bar (UP(S)(O) 15-XX CES87 130 model only), 10.0 bar (all other models). Maximum operating temperature 95°C.
Range of single stage end suction pumps with stainless steel or cast iron pump housings, EPDM ‘O’-rings and wear rings available in low-lead bronze/brass or stainless steel. Cast iron models are coated in black cathodic paint (textured finish) or black epoxy (smooth finish). The pumps are available with carbon graphite/silicon carbide mechanical shaft seal. Impellors are available in cast iron with black cathodic paint, low-lead bronze or stainless steel. The pumps are available with fixed flange, as well as loose flange (model dependent). Maximum working pressure 10.0 or 16.0 bar depending on model. Maximum operating temperatures: Stainless steel and cast iron with (smooth) epoxy coating pumps 85°C. Cast iron pumps with (textured) cathodic paint coating are cold water use only.
Pressure manager pump control unit with a plastic body. The outlet incorporates a non-return valve. Maximum working pressure 10.0 bar. Cold water use only.
‘Alpha’ range of circulator pumps with either a composite (plastic) or stainless steel body, plastic impellor and EPDM ‘O’-rings. The Alpha 1 model B CIL3 has a black motor housing. The Alpha 1 model B and the Alpha 2 model E stainless steel body models have either a black or red motor housing. All other models have a red motor housing. The 1”-1½” models are supplied with EPDM gaskets for the inlet and outlet. The 2” model has fibre/NBR gaskets. Maximum working pressure 10.0 bar. Maximum operating temperature 95°C.
Range of differential (DPI) or relative (RPI) pressure sensors (with or without temperature transmitter) with stainless steel bodies and EPDM ‘O’-rings. The DPI2 model consists of a sensor and fitting for a capillary tube which is used for measuring the differential pressure between either sides of the sensor. Maximum working pressure 30.0 Bar. Maximum operating temperature 100°C.
TP series 200 range of single stage pumps with electrocoated cast iron or bronze bodies, stainless steel impellers and EPDM ‘O’-rings. (TPE models are only available with electrocoated cast iron bodies). The products can incorporate the following shaft seal variations: BQQE (silicon carbide-silicon carbide) & BQBE (Silicon carbide-carbon). The TPE pumps are available with or without a sensor. Maximum working pressure 16.0 bar (TP and TPE40-XXX/2 and TP and TPE40 XXX/2 models). All other models 10.0 bar. Maximum operating temperature: Bronze models are 85°C, cast iron models are cold water use only.
CR(I)(N)(E) ranges of multistage centrifugal pumps incorporating stainless steel impellers, intermediate chamber and outer sleeve. CR(E) versions have cast iron bases and pump heads coated with black cathodic paint. CRI(E) and CRN(E) versions have stainless steel bases and pumpheads. The pumps are available with the following shaft seals HQQ*, HUU*, HUB*, HQB*, where * can be E for EPDM and V for FKM. Maximum working pressures: CR1, 3 or 5 (2-36 stages) Oval flange: 16.0 bar. CR1, 3 or 5 (2-36 stages) DIN/ANSI/JIS flange: 25.0 bar CRI/N1, 3 or 5 (2-36 stages) Flexi clamp with oval flange connection: 16.0 bar CR/I/N1, 3 or 5 (2-36 stages) DIN/ANSI/JIS flange, PJE, Flexi clamp or Triclamp: 25.0 bar CR10 (1-16 stages) Oval flange or DIN/ANSI/JIS flange: 16.0 bar. CR10 (17-22 stages) DIN/ANSI/JIS flange: 25.0 bar. CRI10 (1-16 stages) PJE, Flexi clamp, Flexi clamp with oval connection, Triclamp or DIN/ANSI/JIS flange: 16.0 bar. CRI10 (17-22 stages) PJE, Flexi clamp, Triclamp or DIN/ANSI/JIS flange: 25.0 bar CRN10 (1-22 stages) PJE, Flexi clamp, Flexi clamp with oval connection, Triclamp or DIN/ANSI/JIS flange: 25.0 bar. CR15 or 20 (1-7 stages) Oval flange: 10.0 bar. CR15 or 20 (1-10 stages) DIN/ANSI/JIS flange: 16.0 bar. CR15 or 20 (11-17 stages) DIN/ANSI/JIS flange: 25.0 bar. CRI15 or 20 (1-7 stages) Flexi clamp with oval flange connection: 10.0 bar CRI15 or 20 (1-10 stages) PJE, Flexi clamp, Triclamp or DIN/ANSI/JIS flange: 16.0 bar. CRI15 or 20 (11-17 stages) PJE, Flexi clamp, Triclamp or DIN/ANSI/JIS flange: 25.0 bar. CRN15 or 20 (1-17 stages) PJE, Flexi clamp, Flexi clamp with oval connection, Triclamp or DIN/ANSI/JIS flange: 25.0 bar. CR models: Cold water use only. CRI/CRN models: Cold water use only and from April 2023 99°C.
Page 1 of 4
We use cookies to give you the best possible experience with WRAS. Some are essential to provide website functions and ensure the website is secure. We also use cookies to help us understand how people use the site and to make improvements. Click "Accept All" to enable recommended settings or click "Manage cookies" to adjust your settings. For more details, see our Cookie Policy.