Fagor Industrial S. Coop Approvals


WRAS Approval Number: 1710112

Range of commercial clothes washing machines. Flow is controlled by a solenoid valve and discharges via a type `AB` airgap (verified by test - suitable for backflow protection against fluid category 5). Maximum working pressure 4.0 Bar. Maximum operating temperature 60°C.

  • Section: 2370 Washing Machines
  • Section Subtitle: Clothes. Washing machines in this section will indicate the category of backflow prevention built into each appliance. The location and the use of the washing machine will determine any additional backflow protection that may be required.
  • WRAS Approval Number: 1710112
  • Expiry date: 31/10/2022
  • Note: This appliance has a fluid category 5 backflow prevention device built in. However, the units incorporate a dispensing tray/drawer prior to the ‘AB’ air gap. Therefore, no detergents, softeners or other products are to be placed within the dispenser tray/drawer that represent a risk greater than Fluid Category 3. It is the responsibility of the end user to ensure that this has been met. The approval holder does not supply or recommend any detergents, softeners or other products for use with the machines. R160 applies to all inlets.
  • Size: Nylon braided EPDM lined flexible hose assemblies with ¾” BSP captive nut end connections.
  • Marking: Fagor on control panel. Fagor on door. Fagor, model, operating info on rear panel.
  • Installation Requirements R001 R160 R574
  • Model
    NNormal Speed: LN-11 TP E, LN-11 TP HW, LN-14 TP E, LN-14 TP HW, LN-18 TP E, LN-18 TP HW, LN-25 TP E, LN-25 TP HW, LN-35 TP E, LN-35 TP HW. Rapid Speed: LR-11 TP E, LR-11 TP HW, LR-14 TP E, LR-14 TP HW, LR-18 TP E, LR-18 TP HW, LR-25 TP E, LR-25 TP HW. High Speed: LA-11 TP E, LA-11 TP HW, LA-14 TP E, LA-14 TP HW, LA-18 TP E, LA-18 TP HW, LA-25 TP E, LA-25 TP HW, LA-35 TP E, LA-35 TP HW. Models added May 2018: LN-11 TP S, LN - 14 TP S, LN-18 TP S, LN-25 TP S, CT-35 TP S, LR-11 TP S, LR-14 TP S, LR-18 TP S, LR-25 TP S, LA-11 TP S, LA-14 TP S, LA-18 TP S, LA-25 TP S LA- 35 TP S Models added February 2019: Normal speed: LN-11 TP2 E, LN-11 TP2 HW, LN-11 TP2 S, LN-14 TP2 E, LN-14 TP2 HW, LN-14 TP2 S, LN-18 TP2 E, LN-18 TP2 HW, LN-18 TP2 S, LN-25 TP2 E, LN-25 TP2 HW, LN-25 TP2 S, LN-35 TP2 E, LN-35 TP2 HW, LN-35 TP2 S Rapid speed: LR-11 TP2 E, LR-11 TP2 HW, LR-11 TP2 S, LR-14 TP2 E, LR-14 TP2 HW, LR-14 TP2 S, LR-18 TP2 E, LR-18 TP2 HW, LR-18 TP2 S, LR-25 TP2 E, LR-25 TP2 HW, LR-25 TP2 S High speed: LA-11 TP2 E, LA-11 TP2 HW, LA-11 TP2 S, LA-14 TP2E, LA-14 TP2 HW, LA-14 TP2 S, LA-18 TP2 E, LA-18 TP2 HW, LA-18 TP2 S, LA-25 TP2 E, LA-25 TP2 HW, LA-25 TP2 S, LA-35 TP2 E, LA-35 TP2 HW, LA-35 TP2 S
  • Factor: Fagor Industrial S. Coop
    Company Name
    Fagor Industrial S. Coop
    Address
    B° Santxolopetegi 22 20560 Onati
    Phone
    +34 943 71 80 30
    General Email
    info@fagorindustrial.com
    View All Listings by this Company

Print This Approval


WRAS Approval Number: 1710355

Range of commercial glass washing machines for glass. Flow is supplied via a flexible hose, controlled by solenoid valve. Maximum working pressure 4.0 bar. Cold water supply only.

  • Section: 1310 Glass/Bottle Washers
  • WRAS Approval Number: 1710355
  • Expiry date: 31/10/2022
  • Size: ½” BSP (M)
  • Marking: Company name (FAGOR), maximum temperature, pressure and other tech information on data label located on side panel.
  • Installation Requirements R001 R009
  • Model
    FAGOR E-VO CONCEPT CO-350 AG Glasswasher FAGOR E-VO CONCEPT CO-350 AG B Glasswasher FAGOR E-VO CONCEPT CO-350 AG DD Glasswasher FAGOR E-VO CONCEPT CO-350 AG B DD Glasswasher FAGOR E-VO CONCEPT CO-400 AG Glasswasher AG stand for : version WRAS requires double check valve B stand for : drain pump DD : detergent doser
  • Manufacturer: Fagor Industrial S. Coop
    Company Name
    Fagor Industrial S. Coop
    Address
    B° Santxolopetegi 22 20560 Onati
    Phone
    +34 943 71 80 30
    View All Listings by this Company

Print This Approval


WRAS Approval Number: 1806351

Range of front loading commercial washing machines with flow controlled by solenoid valves and discharged via a type `AB` airgap (verified by test - suitable for backflow protection against fluid category 5). The products are supplied with a dual layer PVC supply hose (grey outer/black inner). Maximum working pressure 4.0 bar. Maximum operating temperature 60°C (hot water connection). Cold supply only (cold water connection).

  • Section: 2370 Washing Machines
  • Section Subtitle: Clothes. Washing machines in this section will indicate the category of backflow prevention built into each appliance. The location and the use of the washing machine will determine any additional backflow protection that may be required.
  • WRAS Approval Number: 1806351
  • Expiry date: 30/06/2023
  • Note: This appliance incorporates a Fluid Category 5 backflow prevention device. At least a single check valve is required on each of the supplies to this fitting because it is for a non-wholesome water application so the materials of construction have not been fully assessed against the requirements of the Regulations.
  • Size: ¾” captive nut on hose inlet.
  • Marking: Model reference, Fagor and other technical information on adhesive label on rear panel.
  • Installation Requirements R001 R150 R574
  • Model
    "LAP-08 TP2 EV, LAP-08 TP2 EP, LAP-08 TP2 HWV, LAP-08 TP2 HWP, LAP-08 TP2 AEV, LAP-08 TP2 AEP, LAP-08 TP2 AHWV, LAP-08 TP2 AHWP, LAP-08 TP2 EP, LAP-10 TP2 EV, LAP-10 TP2 EP, LAP-10 TP2 HWV, LAP-10 TP2 HWP, LAP-10 TP2 AEV, LAP-10 TP2 AEP, LAP-10 TP2 AHWV, & LAP-10 TP2 AHWP
  • Manufacturer: Fagor Industrial S. Coop
    Company Name
    Fagor Industrial S. Coop
    Address
    B° Santxolopetegi 22 20560 Onati
    Phone
    +34 943 71 80 30
    View All Listings by this Company

Print This Approval


WRAS Approval Number: 1811311

Range of undercounter, commercial dishwashing machines. Flow is controlled via solenoid valve that discharges via a Type ‘AA’ air gap (suitable for backflow protection against fluid category 5). The product is supplied with a PVC (grey) inlet hose. Maximum working pressure 4.0 bar. Cold water only. Model added 2nd September 2019 Maximum operating temperature 60°C

  • Section: 2390 Washing Machines
  • Section Subtitle: Dish. Washing machines in this section will indicate the category of backflow prevention built into each appliance. The location and the use of the washing machine will determine any additional backflow protection that may be required.
  • WRAS Approval Number: 1811311
  • Expiry date: 30/11/2023
  • Note: This appliance incorporates a Fluid Category 5 backflow prevention device. The product is supplied with a double check valve for use on all inlets. At least a single check valve is required on each supply to this fitting because it is for a non-wholesome water application so the materials of construction have not been fully assessed against the requirements of the Regulations.
  • Size: ¾” BSP Captive nut (inlet hose)
  • Marking: Fagor and Fagor logo on operating face of appliance. Fagor and other technical information on date plate.
  • Installation Requirements R001 R150
  • Model
    E-VO CONCEPT+ COP-504 E-VO CONCEPT+ COP-504 B E-VO CONCEPT+ COP-504 DD E-VO CONCEPT+ COP-504 B DD E-VO CONCEPT+ COP-504 CI B E-VO CONCEPT+ COP-504 CI DD E-VO CONCEPT+ COP-504 CI B DD E-VO ADVANCE AD-505 AU Models added 2nd September 2019 E-VO CONCEPT+ COP-504 H E-VO CONCEPT+ COP-504 H B E-VO CONCEPT+ COP-504 H DD E-VO CONCEPT+ COP-504 H B DD E-VO CONCEPT+ COP-504 H CI B E-VO CONCEPT+ COP-504 H CI DD E-VO CONCEPT+ COP-504 H CI B DD E-VO ADVANCE AD-505 H AU E-VO ADVANCE AD-505 H SOFT
  • Factor: Fagor Industrial S. Coop
    Company Name
    Fagor Industrial S. Coop
    Address
    B° Santxolopetegi 22 20560 Onati
    Phone
    +34 943 71 80 30
    General Email
    info@fagorindustrial.com
    View All Listings by this Company

Print This Approval


WRAS Approval Number: 1903307

Range of undercounter commercial dishwashing machines, flow is controlled via solenoid valve that discharges via a Type ‘AA’ air gap. The machine incorporates a salt regenerated water softener. Maximum working pressure 4.0 Bar. Cold water only

  • Section: 2390 Washing Machines
  • Section Subtitle: Dish. Washing machines in this section will indicate the category of backflow prevention built into each appliance. The location and the use of the washing machine will determine any additional backflow protection that may be required.
  • WRAS Approval Number: 1903307
  • Expiry date: 31/03/2024
  • Size: ¾” BSP Captive nut.
  • Marking: Fagor and Fagor logo on front of machine. Fagor and other technical information on data plate.
  • Installation Requirements R001 R160
  • Model
    E-VO ADVANCE AD-505 SOFT
  • Manufacturer: Fagor Industrial S. Coop
    Company Name
    Fagor Industrial S. Coop
    Address
    B° Santxolopetegi 22 20560 Onati
    Phone
    +34 943 71 80 30
    View All Listings by this Company

Print This Approval


WRAS Approval Number: 1903341

Range of hood type commercial dishwashing machines. Flow is controlled via solenoid valve and discharges via a Type ‘AA’ air gap. The machines with ‘SOFT’ in the model incorporate a salt regenerated water softener. Maximum working pressure 4.0 bar. Maximum operating temperature 60°C

  • Section: 2390 Washing Machines
  • Section Subtitle: Dish. Washing machines in this section will indicate the category of backflow prevention built into each appliance. The location and the use of the washing machine will determine any additional backflow protection that may be required.
  • WRAS Approval Number: 1903341
  • Expiry date: 31/03/2024
  • Note: This appliance incorporates a Fluid Category 5 backflow prevention device.
  • Size: PVC lined flexible hose assembly with ¾” captive nut end connections
  • Marking: Fagor on front. Adhesive label on lower panel with Fagor, model & technical information.
  • Installation Requirements R001 R009 R160
  • Model
    E-VO CONCEPT+ COP-144 H E-VO CONCEPT+ COP-144 H B E-VO CONCEPT+ COP-144 H DD E-VO CONCEPT+ COP-144 H B DD E-VO CONCEPT+ COP-144 H HRS E-VO CONCEPT+ COP-144 H HRS B E-VO CONCEPT+ COP-144 H HRS B DD E-VO CONCEPT+ COP-144 H HRS DD E-VO CONCEPT+ COP-174 H E-VO CONCEPT+ COP-174 H B E-VO CONCEPT+ COP-174 H DD E-VO CONCEPT+ COP-174 H B DD E-VO CONCEPT+ COP-174 H HRS E-VO CONCEPT+ COP-174 H HRS B E-VO CONCEPT+ COP-174 H HRS B DD E-VO CONCEPT+ COP-174 H HRS DD E-VO ADVANCE AD-125 H E-VO ADVANCE AD-125 H AU E-VO ADVANCE AD-125 H HRS AU E-VO ADVANCE AD-125 H HRS E-VO ADVANCE AD-125 H HRS SOFT E-VO ADVANCE AD-125 H SOFT
  • Manufacturer: Fagor Industrial S. Coop
    Company Name
    Fagor Industrial S. Coop
    Address
    B° Santxolopetegi 22 20560 Onati
    Phone
    +34 943 71 80 30
    View All Listings by this Company

Print This Approval


WRAS Approval Number: 2001345

Range of conveyor type commercial dishwashing machines. Flow is controlled via solenoid valve and discharges via a type `AB` airgap (verified by test - suitable for backflow protection against fluid category 5). The product incorporates a nylon bodied inline strainer with a stainless steel screen as the inlet to the machine. Maximum working pressure 4.0 bar. Maximum operating temperature 60°C

  • Section: 2390 Washing Machines
  • Section Subtitle: Dish. Washing machines in this section will indicate the category of backflow prevention built into each appliance. The location and the use of the washing machine will determine any additional backflow protection that may be required.
  • WRAS Approval Number: 2001345
  • Expiry date: 31/01/2025
  • Size: ¾” BSP(M)
  • Marking: Fagor (manufacturer) address, model no, ref no, serial no and other techcnial information on side panel. Fagor, concept on front panel.
  • Installation Requirements R001 R160 R574
  • Model
    CCO-120 AG CW I. CCO-120 AG CW D. CCO-120 AG HW I. CCO-120 AG HW D. CCO-160 AG CW I. CCO-160 AG CW D. CCO-160 AG HW I. CCO-160 AG HW D. Where: “AG” stand for: AIR GAP. “CW” stand for: COLD WATER. “HW” stand for: HOT WATER. “I” stand for: CONVEYOR BELT- INLET OF BASKET FROM LEFT. “D” stand for : CONVEYOR BELT- INLET OF BASKET FROM RIGHT.
  • Manufacturer: Fagor Industrial S. Coop
    Company Name
    Fagor Industrial S. Coop
    Address
    B° Santxolopetegi 22 20560 Onati
    Phone
    +34 943 71 80 30
    View All Listings by this Company

Print This Approval


WRAS Approval Number: 2004350

Range of atmospheric steaming ovens. The water supply is controlled via a solenoid valve. The products are supplied with dual layer supply hoses with a grey PVC outer layer and black PVC inner layer. Maximum working pressure 4.0 bar. Cold supply only.

  • Section: 1690 Steaming Ovens
  • WRAS Approval Number: 2004350
  • Expiry date: 30/04/2025
  • Size: ¾” BSP captive nut (to supply hose)
  • Marking: Fagor on control panel.
  • Installation Requirements R001 R160
  • Proviso: Discharge to drain must be via a type `AA` `AB` or `AD` airgap in accordance with EN 1717.
  • Model
    FAGOR CONCEPT ACE-061 electric, FAGOR CONCEPT ACE-061 I electric, FAGOR CONCEPT ACE-101 electric, FAGOR CONCEPT ACE-101 I electric, FAGOR CONCEPT ACE-102 electric, FAGOR CONCEPT ACE-201 electric, FAGOR CONCEPT ACE-201-C electric, FAGOR CONCEPT ACE-202 electric, FAGOR CONCEPT ACE-202-C electric, FAGOR CONCEPT ACG-061 gas, FAGOR CONCEPT ACG-101 gas, FAGOR CONCEPT ACG-102 gas, FAGOR CONCEPT ACG-201 gas, FAGOR CONCEPT ACG-201-C gas, FAGOR CONCEPT ACG-202 gas, FAGOR CONCEPT ACG-202-C gas, FAGOR CONCEPT ACE-0632 gas.
  • Manufacturer: Fagor Industrial S. Coop
    Company Name
    Fagor Industrial S. Coop
    Address
    B° Santxolopetegi 22 20560 Onati
    Phone
    +34 943 71 80 30
    View All Listings by this Company

Print This Approval


WRAS Approval Number: 2012323

Shower kit, intended for use with ovens, incorporating a triple layered hose on a reel and a push-button operated shower handset. The inlet of the shower handset incorporates a single check valve cartridge however, the complete product has not been fully tested to demonstrate it provides backflow protection Maximum working pressure 4.0 bar. Cold water use only.

  • Section: 1530 Miscellaneous Fittings
  • WRAS Approval Number: 2012323
  • Expiry date: 31/12/2025
  • Size: 10mm spigot connection
  • Marking: Fagor logo and model on hose reel cover.
  • Installation Requirements R001 R040
  • Model
    SWH
  • Manufacturer: Fagor Industrial S. Coop
    Company Name
    Fagor Industrial S. Coop
    Address
    B° Santxolopetegi 22 20560 Onati
    Phone
    +34 943 71 80 30
    View All Listings by this Company

Print This Approval


Show Per Page
5102050Show All

Back To Directory Sections

Page of 1