Elco Heating Solutions Limited Approvals


#2104346

Range of free standing direct gas fired unvented cyliners with a enamel coating internal lining and magnesium sacrificial anode. Fitted with a combined temperature and pressure relief valve set at 7 bar. Maximum working pressure 6.5 bar. Maximum operating temperature 80°C.

Section:
1890 Unvented Heating Apparatus
WRAS Approval Number:
2104346
Expiry date:
30/04/2026
Size:
1” BSP(M) x 1”BSP(M)
Marking:
Elco, serial no, gas type, capacity and other techcnial on adhesive on label information on body.
Installation Requirements:
R001 R140
Model:
TUDOR NHREC 20 TUDOR NHREC 40 TUDOR NHREC 65 TUDOR NHREX 18 TUDOR NHREX 26 TUDOR NHREX 36 TUDOR NHREX 60 The AEALN / NHREX family of product has straight exhaust that goes from the burner through the tank up to the top of the water heater The COE family of product has a corkscrew exhaust that goes through the tank and exit at the base of the water heater Each water heater through specific setting can be used with 3 different type of gas: - G 20 = Methane - G 25 = Town Gas - G31 = Propane (LPG)
Factor:
Elco Heating Solutions Limited
Company Name
Elco Heating Solutions Limited
Address
Juniper West, 3 Fenton Way Southshields Business Park Basildon
Postcode
SS15 6SJ
Phone
01268 546 700
General Email
enquiries@elco.co.uk

View All Listings by this Company

Print This Approval


#2007391

Range of modular combined heating interface units providing a combination of either hot water, heating or cooling via a plate heat exchanger depending on model options. Heating and cooling circuits incorporate a safety relief valve (set at 3 bar) and expansion vessel and inlet connection can be either top or bottom entry configuration. Maximum working pressure 16 bar (primary, CWS and HWS) 2.5 bar on heating circuit. Maximum operating temperature 85°C.

Section:
1350 Heat Exchangers
WRAS Approval Number:
2007391
Expiry date:
31/07/2025
Size:
See model.
Marking:
ElCO & NEXUS ECOON LABEL INSIDE BOILER ElCO PRINTED ON FRONT COVER
Installation Requirements:
R001
Proviso:
The filling loop supplied must be installed with the appropriate backflow prevention device in accordance with clause G24.2, Guidance to the Water Supply (Water Fittings) Regulations 1999.
Model:
Nexus S-Therm Eco t ¾” BSP (M) Nexus BiTherm Eco ¾” BSP(M)
Factor:
Elco Heating Solutions Limited
Company Name
Elco Heating Solutions Limited
Address
Juniper West, 3 Fenton Way Southshields Business Park Basildon
Postcode
SS15 6SJ
Phone
01268 546 700
General Email
enquiries@elco.co.uk

View All Listings by this Company

Print This Approval


Show Per Page
5102050Show All

Back To Directory Sections

Page of 1

We use cookies to give you the best possible experience with WRAS. Some are essential to provide website functions and ensure the website is secure. We also use cookies to help us understand how people use the site and to make improvements. Click "Accept All" to enable recommended settings or click "Manage cookies" to adjust your settings. For more details, see our Cookie Policy.