Non-verifiable single check valve assembly with chrome plated DZR brass body. Maximum working pressure 14.0 bar. Maximum operating temperature 85ºC.
Range of double check valve assemblies consisting of two spring loaded in-line check valve cartridges housed in a DZR brass or chrome plated DZR brass (CP02-8511 suffix models) body with a drain port between the cartridges. Maximum working pressure 10.0 bar. Maximum operating temperature 85°C.
Tundish with a black metal body and a straight through pattern. The tundish complies with the requirements of an air gap to drain. Maximum operating temperature 99°C.
All pressure, single fixed, dual fixed and variable flow rate ranges of constant flow regulators. Maximum operating temperature (Grey, Natural & White) 85°C. Models UDC ll, N & N-cart have a maximum operating temperature of 60°C.
Range of ceramic cartridge headwork with a plastic body and silicone seals and ‘O’-rings for insertion into specifically dimensioned tap assemblies. Maximum working pressure 4.0 bar. Maximum operating temperature 85°C.
Range of either ¼ turn ceramic disc or non-rising spindle headworks with brass bodies model ML-PW1001 has NBR ‘O’-rings model ML-PW2001 has NBR and silicone ‘O’-rings for insertion into specifically dimensioned bodies. Maximum working pressure 6.0 bar. Maximum operating temperature 85°C.
Non-rising spindle headwork with brass body incorporating NBR ‘O’-rings, To be inserted into specifically dimensioned bodies. Maximum working pressure 10.0 bar. Maximum operating temperature 85°C.
Quarter turn ceramic disc headwork (model FCN0538) and non-rising spindle headwork (model FLG0398) with brass bodies and NBR ‘O’-rings. Maximum working pressure 16.0 bar. Maximum operating temperature 85°C.
Range of ceramic cartridge headworks with plastic bodies and EPDM ‘O’-rings for insertion into specifically dimensioned tap assemblies. Maximum working pressure 10.0 bar. Maximum operating temperature 85°C.
Single hole single outlet (swivel) pull out spray combination tap assembly (chromium plated brass) with ¼ turn ceramic disc headwork and single lever operating members. The spout outlet incorporates a plastic flow aerator and an approved check valve cartridge however, the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum working pressure 10.0 bar. Maximum operating temperature 70°C.
Single hole, single outlet (fixed) combination tap assembly (chromium plated brass) incorporating a sequential headwork controlling both flow and temperature with single lever type operating member. The spout outlet incorporates a plastic flow straightener. Maximum working pressure 5.0 Bar. Maximum operating temperature 85°C.
Single hole, single outlet (fixed) combination tap assembly (chromium plated brass) incorporating a ceramic cartridge headwork with a single lever operating member. The spout outlet incorporates a plastic flow straightener. The product is supplied with a click type waste. Maximum working pressure 5.0 Bar. Maximum operating temperature 70°C.
Single hole, single outlet (fixed) combination tap assemblies (chromium plated brass) incorporating non-rising spindle headworks with cross top operating members. The product is supplied with a click type waste. Maximum working pressure 10.0 bar. Maximum operating temperature 70°C.
Range of single hole, single outlet (fixed) combination tap assemblies (various finishes, see model), incorporating a ceramic cartridge headwork with a single lever operating member. The spout outlets incorporate a plastic aerator. Each hose inlet incorporates an EPDM seal with a stainless steel mesh filter. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C
Range of single hole, single outlet (fixed) combination tap with brass bodies (various finishes, see model). Incorporating a ceramic cartridge headworks and a single lever operating member. The spout outlet incorporates a plastic straightener. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.
Single hole, single outlet (fixed) combination tap assembly (chromium plated brass). Incorporating a ceramic cartridge headwork and a single lever operating member. The spout outlet incorporates a plastic aerator. Maximum working pressure 5.0 bar. Maximum operating temperature 70°C.
Single hole, single outlet (fixed) over the rim (swivel nozzle) bidet combination tap assembly with a brass body (various finished and styles), incorporating a quarter turn ceramic disc headwork with cross top operating members. The spout outlet incorporates a plastic aerator and the product is supplied with a pop-up waste. Maximum working pressure 3.5 bar. Maximum operating temperature 60°C.
Range of single hole, single outlet (fixed) combination tap assemblies with brass bodies (various finishes), incorporating a ceramic cartridge headworks and single lever operating members, and the spout outlet incorporates a plastic aerator. The product can be supplied with or without a pop-up waste arrangement. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.
Range of single hole, single outlet (fixed) combination tap assemblies (chromium plated brass) with a solenoid valve controlling the flow and activated via an infra-red sensor. The spout outlet incorporates a plastic aerator. Maximum working pressure 10.0 bar. Maximum working temperature 60°C.
Range of single hole, single outlet (fixed) combination tap assemblies (chromium plated brass bodies, except for /501 suffix model which is gold plated), incorporating quarter turn ceramic disc headworks or a ceramic cartridge headwork (ELAN113 & DAR113 models only), all with single lever operating members, except GE04 models which have cross top operating members. The spout outlet incorporates a plastic flow straightener, except the DAR113 model which has a plastic aerator. The DLT113 models are supplied with a pop-up waste. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.
Range of single hole, single outlet (fixed) combination tap with brass bodies (various finishes, see model). Incorporating a ceramic cartridge headworks and a single lever operating member. The spout outlet incorporates a plastic straightener. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.
Deck mounted, single hole, single outlet (fixed) combination tap assembly (chromium plated brass) incorporating a ceramic cartridge headwork with a single lever operating member. The spout outlet incorporates a plastic flow straightener. Maximum working pressure 5.0 bar. Maximum operating temperature 60ºC.
Range of single hole, single outlet (swivel) combination tap assemblies (chromium plated brass), incorporating a ceramic cartridge headwork with a single lever operating member. The spout outlet incorporates a plastic flow straightener. Maximum working pressure 5.0 bar. Maximum operating temperature 70°C
Single hole, single outlet (swivel) combination tap assembly (chromium plated brass), incorporating ceramic cartridge headwork with single lever operating member. The spout outlet incorporates a plastic flow straightener. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C
Range of single hole, single outlet (swivel) combination tap assembly (chrome plated brass) incorporating a ceramic cartridge headwork with a single lever operating member. The spout outlets incorporate a plastic aerator. Maximum working pressure 10.0 bar. Maximum operating temperature 60ºC.
Range of single hole, single outlet (swivel) combination tap assemblies (chromium plated brass), incorporating a quarter turn ceramic disc headworks and single lever operating members. The spout outlet incorporates a plastic aerator. Inlets incorporate an approved check valve cartridge however, the complete assembly has not been tested to demonstrate it provides adequate backflow protection. Maximum working pressure 5.5 bar. Maximum operating temperature 60°C.
Range of single hole, single outlet (swivel) combination tap assembles with brass bodies (various finishes), incorporating a non-rising spindle headworks and cross top operating members. The spout outlet incorporates a plastic flow straightener. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.
Range of single hole, single outlet (swivel) combination tap assemblies (chrome plated brass), incorporating a ceramic cartridge headwork with a single lever operating member. The spout outlet incorporates a plastic aerator. Supplied with approved single check valve with integral servicing valve for both inlets verified by test (suitable for backflow protection against Fluid Category 2) . Maximum working pressure 5.0 bar. Maximum operating temperature 60°C
Two hole single outlet (swivel) combination tap assembly (chromium plated brass body) with non rising spindle headwork and cross top operating members. Outlet incorporates a plastic flow straightener and the fitting is supplied with metal backnuts. Maximum working pressure 10.0 bar. Maximum operating temperature 70°C.
Range of single hole, single outlet (swivel) combination tap assemblies incorporating brass bodies (various finishes) and ceramic cartridge headwork with single lever operating member. The spout outlets incorporate a plastic aerator. Maximum working pressure 5.0 bar. Maximum operating temperature 65°C.
Range of two hole, single outlet (fixed) combination tap assemblies (chromium plated brass), incorporating quarter turn ceramic disc headworks with single lever operating members. The spout outlet incorporates a plastic flow straightener. The product is supplied with plastic backnuts. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.
Two-hole, single outlet (fixed) combination tap assembly (chromium plated brass), incorporating quarter turn ceramic disc headworks with single lever operating members. The products are supplied with metal backnuts and the spout outlets incorporate a plastic aerator or a plastic flow straightener (supplied with both). Maximum working pressure 5.0 Bar Maximum operating temperature 60°C.
Wall mounted concealed single lever basin mixer (brass body), having a ceramic cartridge headwork which control the flow and temperature with a lever type operating member. The spout outlet (chromium plated brass) incorporates an aerator. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.
Two-hole, single outlet (fixed) combination tap assemblies (chromium plated brass), incorporating ceramic cartridge headwork with single lever operating member. The spout outlets incorporate a plastic aerator and the products are supplied with metal backnuts. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.
Wall mounted two-hole, single outlet (fixed) combination tap assemblies incorporating brass bodies (various finishes) and ceramic cartridge headwork with a single lever operating member. The spout outlets incorporate a plastic aerator. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.
Range of two hole single outlet (fixed) combination tap assembly (chromium plated brass) incorporating a non-rising spindle headwork with cross top operating members and a manually operated diverter to shower outlet. Products are supplied with a hose and handset and metal backnuts. Maximum working pressure 10.0 bar. Maximum operating temperature 70°C.
Two hole metal single outlet (fixed) combination tap assembly (chromium plated brass) incorporating quarter turn ceramic disc headwork with single lever operating members and a self-cancelling diverter to shower outlet. The spout outlet incorporates a plastic flow straightener and the product is supplied with metal backnuts, hose and handset. Maximum working pressure 10.0 bar. Maximum operating temperature 70°C.
Range of wall mounted, two-hole, single outlet (swivel) combination tap assemblies (chromium plated brass), incorporating ceramic cartridge headwork with single lever operating members. The spout outlets incorporate a plastic flow straightener. The inlet offset unions incorporate a servicing valve and the inlets to the taps incorporate a plastic flow restrictor. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.
Two hole, single outlet swivel combination tap assembly (chrome plated brass), incorporating non-rising spindle headworks with dome type operating members. The spout outlet incorporates a plastic flow straightner. The product is supplied with Metal backnuts. Maximum working pressure 8.0 bar. Maximum operating temperature 60°C.
Range of three hole, metal, single outlet (fixed) combination tap assemblies available with various finishes (see models). Incorporating quarter turn ceramic disc headwork with various operating members (see models). The spout outlet incorporates a plastic aerator. Products are supplied with metal backnuts & lever type pop-up waste. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.
Range of wall mounted, three-hole, single outlet (fixed) combination tap assemblies incorporating brass bodies (various finishes) and quarter turn ceramic disc headworks with dome type or single lever operating members. The spout outlets incorporate a plastic aerator. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.
Range of deck mounted, four hole, single outlet (fixed) combination tap assemblies (chromium plated brass). Incorporating quarter turn ceramic disc headworks and either single lever (AE89TF) or cross top (AE88TF) operating members. The product includes a self-cancelling diverter to shower outlet, metal backnuts and an approved handshower. The product also incorporates an approved check valve on the shower outlet inlet, and a flow regulating approved check valve on the handshower, however, neither complete products have been fully tested to demonstrate backflow protection. Maximum working pressure: 3.5 bar. Maximum operating temperature 60ºC.
Range of floor mounted, single outlet, combination tap assemblies with brass bodies (various finishes), incorporating ceramic cartridge headworks and self-cancelling diverter to shower outlet. The spout outlets incorporate plastic aerators. The product is supplied with a shower hose and handset. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.
Range of wall mounted spout outlets (chromium plated brass) incorporating a plastic flow regulator at the inlet. Model 13800670 incorporates a plastic aerator at the outlet. Maximum operating temperature 60°C.
Floor standing spout outlet (chromium plated brass) and concealed body (cast brass body) Maximum operating temperature 60°C.
Range of spout outlets with brass bodies (various finishes), EPDM ‘O’-rings and a plastic aerator. Maximum operating temperature 60°C.
Range of expansion vessels with stainless steel bodies and rubber diaphragms. Maximum working pressure 10.0 bar. Cold water use only.
Filling loop assembly consisting of an in-line isolation valve, an in-line double check valve assembly which incorporates an isolation valve (suitable for back flow protection against fluid category 3) and a stainless steel braided EPDM lined hose. The isolation valves are operated via a single lever. Maximum working pressure 10.0 bar. Maximum operating temperature 90°C.
Range of water filters comprising of plastic filter cartridges with carbon blocks and plastic filter heads for use with 'John Guest LLDPE' pipe. Maximum working pressure 8.6 bar. Cold water use only.
Range of water filters comprising of polypropylene housings and caps. The filter head incorporates an approved single check valve cartridge however, the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum working pressure 7.0 bar. Cold water use only.
Range of brass press fittings with EPDM ‘O’-rings for use with Rifeng B1 PEX/AL/PEX multilayer pipe. Maximum working pressure 10.0 bar. Maximum operating temperature 95°C.
Range of brass press fittings with EPDM ‘O’-rings for use with EBRILLE multilayer pipe. Maximum working pressure 10 bar. Maximum operating temperature 95°C.
‘ISR’ range of copper, DZR brass or gunmetal capillary, lead free solder ring and threaded fittings for use with copper pipe. For above ground use only. Maximum working pressure 16.0 bar. Maximum working temperatures 99°C.
Range of brass compression fittings for use with copper pipe. Above ground use only. Maximum working pressure 16.0 bar. Maximum operating temperature 85°C.
Range of press-fit fittings with brass bodies and EPDM `O`-rings for use with copper pipe manufactured in accordance with EN1057. Maximum working pressure 16.0 bar (sizes 12mm to 34mm). Maximum working pressure 10.0 bar (sizes 35mm to 54mm). Maximum operating temperature 90°C.
Range of WC dual flush drop valves with an ABS body and silicon seal. The valves are operated via a push button assembly for either full or reduced flush and incorporate an internal adjustable height overflow. Cold water use only.
Range of commercial glass washing machines with flow controlled via a solenoid valve. The products are supplied with a dual layer supply hose (Grey PVC outer/Black PVC inner) with ¾” captive nuts at either end and a loose double check valve assembly (suitable for backflow protection against Fluid Category 3) for installation prior to the inlet hose. Maximum working pressure 4.0 Bar. Cold water use only.
Copper plate heat exchanger with copper connections, incorporating 72 fins. Maximum working pressure Heating circuit 3.0 bar, Sanitary circuit 8.0 bar Maximum operating temperature 99°C
An in-line ultra-sonic water meter with brass or plastic bodies (see model). Maximum working pressure 16.0 bar. Maximum operating temperature 70°C.
Range of water meters with black nylon bodies and NBR ‘O’-rings. Maximum working pressure 16.0 bar. Cold water use only.
Crane brass pressure test point. Maximum working pressure 25.0 bar. Maximum operating temperature 85°C.
Hattersley brass pressure test point. Maximum working pressure 25.0 bar. Maximum operating temperature 85°C.
‘Cart’ range of plastic flow regulators within a plastic housing and either silicone, EPDM or NBR sealing gaskets and optional stainless steel filter. Maximum working pressure 5.0 bar. Maximum operating temperature 85°C.
Wall plate elbow (105° angle) with a brass body. Maximum operating temperature 100°C
Manifold with a brass body and 5 outlets. Maximum working pressure 15.0 bar. Maximum operating temperature 100°C.
Range of axial expansion joints with either threaded or flanged end connections. Maximum working pressure 16.0 bar. Maximum operating temperature 100°C.
Wall mounted shower arm with brass body (various finishes). Maximum operating temperature 85°C.
Range of domestic water pressure booster pumps with brass impellors, plastic bodies and an accumulator. Models are supplied with a pressure reducing valve, isolation valve, inline strainer and non-return valve. Maximum working pressure 4.5 bar. Maximum operating temperature 35°C.
Range of vertical multistage pumps with stainless-steel bodies, stainless-steel impellers, intermediate chambers, shaft and outer sleeve. Cold water use only. Maximum working pressure 12.0 bar.
Range of circulator pumps with stainless steel bodies and plastic impellers. Maximum working pressure 10.0 bar. Maximum operating temperature 65°C.
Range of submersible pumps incorporating stainless-steel bodies and plastic impellers. Maximum working pressure 23.0 bar or 36.0 bar (please refer to model). Maximum operating temperature 35°C.
‘DUSO’ timed-flow control shower column with black plastic spray plate. The product is operated by a hydraulically actuated push paddle control. Maximum working pressure 5.0 bar. Maximum operating temperature 50°C.
Range of, wall mounted shower outlets (chromium plated brass). Inlets incorporate a plastic flow regulator. Maximum operating temperature 60°C.
Shower outlet incorporating chromium plated brass body and a plastic flow regulator at the inlet. Maximum operating temperature 60°C
Range of shower handsets with ABS bodies (various finishes, see model). The spray outlet is either multifunction or single function depending on series (see note). Open outlet use only. Maximum operating temperature 60°C.
Range of shower handsets with chromium plated ABS bodies. Some models incorporate multi-spray patterns (all excluding H01011, H03021, H04011, H21011, H34021). Maximum operating temperature 60 °C.
Range of Wall Mounted Elbow, Hose and Handsets (chromium plated brass). The wall elbow and shower handset both incorporate an approved check valve cartridge, however, the complete product has not been fully tested to demonstrate it provides backflow protection. The handset also incorporates a flow regulator built into the check valve. Maximum operating temperature 60ºC.
Wall mounted shower outlet (chromium plated brass) with EPDM and NBR rubber ‘O’-rings. Open Outlet use only. Maximum operating temperature 85 °C
Range of shower handsets in chromium plated brass on model MH1 or chromium plated ABS on model MH1A. Model MH2 is supplied with an approved flow regulator. Maximum operating temperature 65°C.
Range of shower handsets and holder outlets consisting of a shower handset, hose and a wall mounted holder and outlet or a shower handset only. The shower handset and wall mounted holder incorporates an approved check valve cartridge however, the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum working pressure 5.0 bar (wall mounted holder). Shower hose and handset is open outlet use only. Maximum operating temperature 60°C.
Range of ceiling mounted shower arms with brass bodies (various finishes) having a threaded connection at the outlet and incorporating EPDM ‘O’-rings. Maximum operating temperature 60°C.
Shower outlet having brass bodies (various finishes) and NBR ‘O’-rings Maximum operating temperature 60°C.
Shower kit consisting of a shower handset (matt black or chrome plated plastic), riser rail and PVC lined multi-layered shower hose with brass connections, EPDM 'O'-rings and strainer. Maximum operating temperature 60°C
Range of shower handsets with chromium plated ABS bodies. Some models incorporate multi-spray patterns. Maximum operating temperature 60 °C.
Range of showerbob Edge handsets with chromium plated ABS bodies. Maximum operating temperature 60 °C.
Wall mounted shower kit incorporating a plastic shower handset (various finishes), shower hose and riser rail. Maximum operating temperature 60°C.
Deck mounted, pull-out shower hose and handset. The inlet of the shower handset incorporates an approved check valve cartridge, however, the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum operating temperature 85°C.
Wall mounted shower set comprising of an inlet connection, shower handset, shower holder and EPDM lined shower hose. Maximum working pressure 5.0 bar. Maximum operating temperature 70⁰C
Range of wall mounted shower outlets with brass bodies (various finishes). The 24 004 xxx, 24 014 xxx and 35 279 xxx models are supplied with ceiling mounted shower arm. The 24 005 xxx, 24 015 xxx, 35 275 xxx and 35 280 xxx supplied with wall mounted shower arm. The 24 005 xxx, 24 015 xxx, 35 275 xxx & 35 280 xxx models incorporate stainless steel strainers on the inlet. The 24 014 xxx & 24 015 xxx models incorporate plastic flow regulators on the inlet. Maximum operating temperature 60°C.
Range of in-line ‘Y’-patterned strainers with flanged cast iron bodies (blue epoxy powder coated) and stainless steel mesh strainers. The strainers also incorporate a drain plug. Maximum working pressure 25.0 bar. Maximum operating temperature 85°C.
Range of in-line `Y`-patterned strainers with bronze bodies incorporating stainless steel mesh strainers and PTFE washers. Maximum working pressure 20.0 bar. Maximum operating temperature 85°C.
Range of in-line `Y`-patterned strainers with bronze bodies incorporating stainless steel mesh strainers and PTFE washers. Maximum working pressure 20.0 bar. Maximum operating temperature 85°C.
Range of in-line `Y`-patterned strainers with bronze bodies incorporating stainless steel mesh strainers and PTFE washers. Maximum working pressure 20.0 bar. Maximum operating temperature 85°C.
Range of in-line `Y`-patterned strainers with bronze bodies incorporating stainless steel mesh strainers and PTFE washers. Maximum working pressure 20.0 bar. Maximum operating temperature 85°C.
Range of in-line `Y`-patterned strainers with bronze bodies incorporating stainless steel mesh strainers and PTFE washers. Maximum working pressure 20.0 bar. Maximum operating temperature 85°C.
521 Range of pressure switches with stainless steel bodies (1.4305 / AISI 303 or 1.4404 / AISI 316L see model) and EPDM ‘O’-rings. Maximum working pressure range 0-60.0 bar (see model). Maximum operating temperature 99°C
Flow through valve (chromium plated brass) incorporating EPDM ‘O’-rings, PTFE seals, a drain valve, isolation valve and water mixing feature for connection to expansion vessels. Maximum working pressure 10.0 bar. Cold water use only.
Range of pillar taps (chromium plated brass) incorporating quarter turn ceramic disc headwork with either cross top, single lever or dome type operating members. The DLT SPEC103 model is supplied with metal backnuts. All other models are supplied with plastic backnuts. The spout outlets incorporate a plastic flow straightener. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.
Range of single hole, single outlet (fixed) combination tap assemblies (chromium plated brass) incorporating quarter turn ceramic disc headworks, and various operating members. The spout outlet incorporates a plastic flow straightener. Fittings are supplied with either brass or plastic backnuts depending on model. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.
Range of pillar taps having brass bodies (chromium plated) and non-concussive headworks with dome type operating members. The outlet incorporates a plastic aerator and the product is supplied with plastic backnuts. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.
Range of basin pillar taps (chromium plated brass or gold effect finish /501 model) with rising spindle headworks and cross top operating members. The spout outlet incorporates a plastic flow straightener. The products are supplied with plastic backnuts. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.
Range of pillar taps (chrome plated brass) with non-rising headworks with dome type operating members (TRDCBSNT, TRDCSPTC, TRDCBTHT) or quarter turn ceramic disc headworks with single lever operating members (TRDCLBSN, TRDCLBTH, TRDSLBHT, TRDSLBST). The spout outlet incorporates a plastic flow straightener. The product is supplied with Metal backnuts. Maximum working pressure 7.0 bar. Maximum operating temperature 60°C.
Range of pillar taps (chromium plated brass) with ¼ turn ceramic disc headworks and single lever operating members. The spout outlet incorporates a plastic flow straightener. The product is supplied with metal backnuts. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.
Range of pillar taps with brass bodies (chromium plated) with a non-rising spindle headwork and brass backnuts. Outlets incorporate a plastic flow straightener. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C
Range of stainless steel or nylon braided, PEX lined flexible hose assemblies with various brass end connections. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.
Range of stainless steel braided, PEX lined hoses incorporating various brass end connection configuration options. Maximum working pressure 10.0 bar. Maximum operating temperature 70°C.
Range of stainless-steel braided hoses incorporating a TPSiV liner. Maximum working pressure 10.0 bar. Maximum operating temperature 85°C.
Range of indirectly heated stainless-steel storage cylinders. The secondary circuit is factory fitted with a temperature and pressure relief valve set at 7.0 bar@90˚C. A safety kit (manifold) consisting of a check valve, strainer, an expansion relief valve set at 6.0 bar and a pressure reducing valve set at 3.5 bar is provided. A tundish, expansion vessel and an approved filling loop is also supplied Maximum working pressure secondary circuit 5.5 bar. Maximum operating pressure primary circuit 2.5 bar. Maximum operating temperature 70˚C.
Range of concealed flow controls (brass body with various different finishes) incorporating two, quarter turn ceramic disc headworks with single lever operating members controlling the flow to an external outlet (not supplied). Model BK2 is a flow control with adjustable bracket and collection box. Model BK2A is a flow control with bracket. Model BK2B is a flow control. Maximum working pressure 10.0 bar. Maximum operating temperature 70°C
Wall mounted exposed thermostatic blending valve (chromium plated brass body) incorporating a half turn ceramic disc headwork controlling the flow to either the overhead shower or hand shower with a dome type operating member. The temperature is controlled via thermostatic cartridge with a manual override button and dome type operating member. The inlets incorporate stainless steel strainers and approved check valve cartridge, however, the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.
Range of wall mounted, concealed thermostatic shower valves with brass bodies (various finishes), incorporating quarter turn ceramic disc headworks controlling the flow with a single lever operating member. The temperature is controlled independently via a thermostatic cartridge with cross top operating members incorporating a manual override button, the inlets incorporate approved check valve cartridges, however, the complete product has not been fully tested to demonstrate it provides backflow protection and a stainless-steel strainer. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.
Range of concealed thermostatic shower valves (brass bodies) incorporating quarter turn ceramic disc headwork controlling the flow with cross top, dome type or single lever operating members. The temperature is controlled independently via a thermostatic cartridge with cross top, dome type or single lever operating members. Product also incorporates a two position manual diverter. Both inlets incorporate an approved single check valve cartridge however, the complete product has not been fully tested to demonstrate it provides backflow protection and stainless steel strainers. Maximum working pressure 5.0 bar. Maximum operating temperature 80°C.
Range of wall mounted two hole, shower outlet thermostatic shower mixing valves (chromium plated brass). Flow is controlled by a quarter turn ceramic disc headwork and temperature is independently controlled via a thermostatic cartridge with cross top, dome type or single lever operating members. Inlets incorporate stainless steel strainers and approved single check valve cartridges however, the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum working pressure 5.0 bar. Maximum operating temperature 80°C.
Range of wall mounted bar type thermostatic shower valves (chromium plated brass) incorporating quarter turn ceramic disc headwork controlling the flow with single lever type operating members. The temperature is controlled independently via a thermostatic cartridge also using single lever type operating member. Both inlets incorporate stainless steel strainers and approved single check valve cartridge however, the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum working pressure 5.0 bar. Maximum operating temperature 65°C.
Range of wall mounted thermostatic mixing valves (chromium plated brass) incorporating a sequential headwork controlling both flow and temperature using a single lever operating member. Inlets incorporate servicing valves and approved check valve cartridges however, the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum working pressure 5.0 bar. Maximum operating temperature 65°C.
Single hole, single outlet combination tap assembly (chromium plated brass) incorporating a sequential headworks with single lever operating member to control both the flow and temperature. The outlet incorporates a plastic flow straightener. The product also incorporates a single check valve assembly (verified by test as suitable for backflow protection against Fluid Category 2). Maximum working pressure 10.0 bar. Maximum operating temperature 60ºC.
Wall mounted exposed bar type thermostatic blending valve (chromium plated brass) with a half turn ceramic disc headwork controlling the flow and a thermostatic cartridge controlling the temperature, both with cubed type operating members incorporating manual override buttons. Each inlet incorporates a stainless-steel strainer and an approved check valve cartridge however, the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum working pressure 5.0 bar. Maximum operating temperature 60.0°C
Wall mounted, concealed, thermostatic mixing valves with brass bodies (various finishes). The flow is controlled independently via a quarter turn ceramic disc headwork with single lever operating members. The temperature is controlled independently via a thermostatic cartridge with single lever operating member which incorporates a manual override button Both inlets incorporate approved check valve cartridge however, the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum working pressure 5.0 bar. Maximum operating temperature 85°C.
Wall mounted, thermostatic mixing valve (various finishes), incorporating a ceramic cartridge diverter controlling the flow between the 3 outlets and the off position. The temperature is controlled independently via a thermostatic cartridge with single lever operating members which incorporate a manual override button. Both inlets incorporate an approved check valve cartridge however, the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum working pressure 5.0 bar. Maximum working temperature 85°C.
Wall mounted, thermostatic shower valve (chromium plated brass). The flow is controlled by a quarter turn ceramic disc headwork with a dome type operating member. The temperature is controlled by a thermostatic cartridge with dome type operating member incorporating a manual override button. Both inlets incorporate an approved check valve cartridge however, the complete product has not been fully tested to demonstrate it provides backflow protection. The product is supplied with a stainless steel braided, PVC lined shower hose, chrome plated plastic shower handset and riser rail. The inlet of the shower handset incorporates a plastic flow restrictor. Maximum working pressure 5.0 bar. Maximum operating temperature 65°C
Thermostatic blending valve incorporating a thermostatic cartridge controlling the temperature and ceramic disc headwork controlling the flow with dome type operating members. The inlets incorporate an approved check valve cartridge, however, the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum working pressure 5.0 bar. Maximum operating temperature 85°C
Range of wafer and fully lugged butterfly valves (lever or handwheel operation) with a cast iron body (blue epoxy coated), EPDM seat and stainless steel disc. Maximum working pressure 25.0 bar. Maximum operating temperature 85°C.
Combined pressure and temperature relief valves with DZR brass bodies, stainless steel springs, silicone diaphragm and PTFE washers. The valves incorporate lever easing gear. The valves are factory pre-set at 6.0 bar (PTEM510001), 7.0 bar (PTEM510002) or 10.0 bar (PTEM510003). Maximum operating temperature 95°C.
Manually operated regulating valves with gunmetal bodies, controlled via a non-rising spindle. Valves incorporate PTFE gasket and EPDM ‘O’-rings. Maximum working pressure 16.0 bar. Maximum operating temperature 85°C.
Range of spring loaded, resilient trim, non-return valves with cast iron bodies (blue epoxy powder coated) with stainless steel discs and an EPDM seal. Maximum working pressure 25.0 bar. Maximum operating temperature 85°C.
Range of spring loaded, resilient trim, non-return valves with epoxy coated ductile iron bodies, stainless steel discs and EPDM seats. Maximum working pressure 16.0 bar. Maximum operating temperature 85⁰C
536 series range of adjustable, in-line pressure reducing valves with DZR brass bodies and EPDM ‘O’-rings. The inlet incorporates a stainless steel strainer. Models are supplied with a pressure gauges. Outlet pressure setting ranges between 6.0 and 10.0 bar. Maximum inlet supply pressure 25.0 bar. Maximum operating temperature 80°C.
‘Predator pressure reducing valve’ range of manually adjustable pressure reducing valves with DZR brass bodies, EPDM’O’-rings and a stainless steel filter. The products are adjustable between 1.0 and 6.0 bar and are supplied with an optional pressure gauge. Maximum supply pressure 20.0 bar. Maximum operating temperature 80°C.
Range of pre-set pressure relief valves incorporating DZR brass bodies and an EPDM diaphragm, (for pre-set pressures see model). The valve is fitted with hand operated rotating easing gear. Maximum working pressure is the same as the pre-set pressure (see model). Maximum operating temperature 85°C.
Range of lever or screw driver operated in-line spherical valves (chromium plated brass body), brass ball and EPDM sealing ring. Maximum working pressure 10.0 bar. Maximum operating temperature 85°C.
Range of in-line spherical valves (brushed chrome DZR brass body) with lever (250400) or butterfly (250300 & 29284) operating members, DZR brass ball (chromium plated brass) and PTFE seats and washers. Maximum working pressure 10.0 bar. Maximum operating temperature 100°C.
“In-Line Thermal Disinfection Unit” comprising of a manual diverter incorporating two spherical valves controlling both the hot and cold flow. Maximum working pressure 10.0 bar. Maximum operating temperature 85°C.
Aangled spherical valve (screwdriver operated) with DZR brass bodies, PTFE seats and NBR seals. Maximum working pressure 10.0 bar. Maximum operating temperature 100°C.
AI-373 range of lever handle operated brass bodied spherical valves having a chromium plated brass ball and EPDM ‘O’-rings. Maximum working pressure 25.0 bar. Maximum operating temperature 100°C.
Screwdriver operated spherical valves with DZR brass bodies, PTFE seats and NBR seals. The fittings incorporate two approved single check valve cartridges however, the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.
Range of spherical valves with single lever or butterfly operating member, bronze bodies, bronze ball (models 229F-15, 229F-20, 229F-25 229F-32, 229F-40 & 229F-50) all other models have a brass ball and PTFE seats. Maximum working pressure 40.0 bar (model: 229F-15, 229F-20, 229F-25, 229F-32, 229F-40, 229F-50) Maximum working pressure 32.0 bar (model: 254-8, 254-10, 254-15, 254-20, 254-25) Maximum working pressure 25.0 bar (model: 254-32, 254-40, 254-50, PB6715, PB6722, PB6728) Maximum working pressure 16.0 bar (model: 254-65, 254-80, 254-100) Maximum operating temperature 85 ºC.
Range of lever operated spherical valves incorporating brass bodies, brass or stainless-steel balls, PTFE seats and EPDM ‘O’ rings. Pressfit connections are for use with copper pipe. Maximum working pressure 16.0 bar. Maximum operating temperature 85.0°C
Range of EFFAST spherical valves with plastic bodies incorporating EPDM ‘O’-rings. The inlet incorporates a plastic flow regulator. Cold water use only. Maximum working pressure 15.0 bar. 4” – 10.0 bar
Range of PVC-U of double union spherical valves having PTFE seats and EPDM ‘O’-rings. Maximum working pressure 16.0 bar. Cold water use only.
Range of ABS double union spherical valves with plastic bodies and EPDM ‘O’-rings for use with ABS class E pipe to BS5391. Maximum working pressure 15.0 bar. Cold water use only.
Range of gate valve with ductile iron bodies, wedge and bonnet (blue epoxy powder coated) and EPDM `O` rings and gaskets. Valves are operated via a non-rising spindle headwork. Maximum working pressure 16.0 bar. Maximum operating temperature 60°C.
Range of non-rising spindle gate valves with DZR brass bodies, with PTFE stem packing and gaskets. Operating members are either handwheel operated or lockshield. Maximum working pressure 20.0 bar. Maximum operating temperature 100°C.
Range of non-rising spindle gate valves with DZR brass bodies, with PTFE stem packing and gaskets. Operating members are either handwheel operated or lockshield. Maximum working pressure 20.0 bar. Maximum operating temperature 100°C.
Range of screw down stop valves with brass bodies (Models: M34040000, M34060000, M34080000, M34150000, M35200000, M34220000, M35250000 and M34280000) Bronze bodies (models: M34100000, M34120000, M34160000, M34350000, M34420000, M34540000, M35152000, M35152500 and M35222500) Fittings incorporate EPDM seat washers and PTFE seals. Maximum working pressure 16.0 bar. Maximum operating temperature 99°C.
Range of manually operated balancing valves (DZR Brass) with a non-rising spindle balancing mechanism, DZR brass discs and EPDM gasket & ‘O’-rings. Maximum working pressure 20.0 bar. Maximum operating temperature 99ºC.
Range of water conditioners incorporating Ball valves. TurboMAG models Simplex, Duplex Skid, Duplex Wall and Quadplex Skid incorporate approved check valve cartridges however, the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum working pressure 10.0 bar.
UV Home’ range of UV disinfection units with 304L or 316L stainless steel bodies (see model) and EPDM ‘O’-rings. Maximum working pressure 6.0 bar or 10.0 bar (see model). Maximum operating temperature 35°C.
`Talbot, Atplas, Ebco & S Booth` ranges of injection moulded, acetal fittings. Talbot fittings available in: F10 black, F20 blue, F20 black, F10 natural, F20 natural & F10 & F20 black. Atplas fittings available in: F10 natural, F20 natural, F10 & F20 natural & F20 red. Ebco fittings available in: F10 natural, F20 natural, F20 blue, F20 red, F20 yellow & F20 black. S Booth fittings available in: F20 natural. For use with water up to 60°C.
'Delrin®100P NC010, 100P BK602, 500P NC010, 500P BK602, 900P NC010 and 900P BK602'. Black coloured and natural (appears white coloured), injection moulded acetal material. For use with water up to 23°C.
'Estaform K1050 GF Naturale'. Off-white coloured, injection moulded POM material. For use with water up to 60°C.
'CY103'. Dark grey coloured, cold pressed, phenolic resin impregnated carbon graphite seal ring. For use with water up to 85°C.
'CD 101'. Grey coloured, compression moulded silicon carbide ceramic disc. For use with water up to 85°C.
'M-AC010'. Factory applied, blue coloured epoxy powder coating. Apply and cure as per manufacturer's user manual 'rev. 2.0' dated 12/03/2019. For use with water up to 85°C.
'Luberpox-2K-DS-Lackfarbe IV805X3/IW 80'. Factory applied, blue coloured, two-component epoxy coating comprising of a base and hardener. Mix base and hardener in a 5:1 weight ratio. Cure for 7 days@23°C. For use with water up to 23°C. This material is only approved for the mixing and curing conditions that appear on the approval. If the mixing and/or curing conditions are varied from those specified on the approval then the materials are not covered by the scope of the approval.
EUROKOTE® 711.92BF bleu 5012, EUROKOTE® 711.92BF bleu 5015, EUROKOTE® 711.92BF bleu 5005 CR, EUROKOTE® 711.92BF bleu 5005 & EUROKOTE® 711.92BF bleu 5017. EUROKOTE® 711.92BF noir 9005. EUROKOTE® 711.92 bleu 5012, EUROKOTE® 711.92 bleu 5015, EUROKOTE® 711.92 bleu 5005, EUROKOTE® 711.92 bleu 5005 CR & EUROKOTE® 711.92 bleu 5017. EUROKOTE® 711.92 noir 9005. EUROKOTE® 711.92 BF Brun Rouge & 711.92 Brun Rouge Factory applied, blue, black or red coloured epoxy coatings. Apply as per manufacturer's technical data sheets. Cure for 2 minutes@200°C. For use with water up to 85°C. These materials are only approved for the curing conditions that appear on the approval. If the cure conditions are varied from those specified on the approval then the materials are not covered by the scope of the approval.
'Abcite 1060 DW Blue & Abcite X60 DW Blue'. Factory applied, blue coloured thermoplastic powder coatings applied by dipping in a fluidised bed. Pre-heat substrate the coating is to be applied to for 12 minutes@280°C. Post-heat for 5 minutes@160°C. For use with water up to 23°C. These materials are only approved for the pre-heat and post-heat conditions that appear on the approval. If the pre-heat and/or post-heat conditions are varied from those specified on the approval then the materials are not covered by the scope of the approval.
'Endolac® 245.10'. Factory applied, black coloured bituminous paint. Apply as per manufacturer's data sheet 'Version dated 05/09/2013'. Cure for 7 days at 20°C. For use with water up to 50°C. This material is only approved for the curing conditions that appear on the approval. If the cure conditions are varied from those specified on the approval then the material is not covered by the scope of the approval.
'Kopatch PC300'. Factory applied, blue coloured, two-component epoxy coating. Mix part A (blue coloured liquid) and part B (colourless liquid) in a 5:1 mass ratio. Cure for 7 days@25°C. For use with water up to 23°C.
'Novapress Ambition’ (grey coloured) and ‘Novaform 660' (light green on one side and beige on the other). Fibre/NBR gasket materials manufactured by calendaring. For use with water up to 85°C. For use only as a jointing/gasket material having been tested at a reduced surface area to volume ratio.
'Tesnit BA-U'. Blue coloured fibre/NBR material. In March 2023, 'Tesnit BA-U', yellow coloured fibre/NBR material was added to the approval. Both blue and yellow are manufactured by calendaring and are for use with water up to 85°C. For use only as a jointing/gasket material having been tested at a reduced surface area to volume ratio.
'Tesnit BA-50'. Green coloured NBR/fibre material manufactured by calendering. For use with water up to 85°C. For use only as a jointing/gasket material having been tested at reduced surface area to volume ratio.
'AF-300 B Pro'. Blue coloured NBR/fibre gasket material. For use with water up to 85°C. For use only as a jointing/gasket material having been tested at reduced surface area to volume ratio
'BK GRP Tank Panel'. Beige coloured, compression moulded GRP panel. For use with water up to 50°C.
'Sanibiw Dynamic'. Multi-layered, extruded hoses comprising of an off-white, transparent silicone inner layer, white, opaque PES yarn reinforcement layer and black coloured, silicone outer layer. The inner layer has a tested in-radius size of between 0.4mm & 0.8mm. For use with water up to 85°C.
'TP1'. Factory applied, colourless solid lubricant. Apply as per manufacturer's instructions 'LDAP-005', issue 1, dated 11/11/2016. For use with water up to 85°C.
'Loxeal Olio 1000'. Clear, silicone oil based lubricant. For use with water up to 70°C.
'Berusil SM 2000'. Clear, liquid lubricant. Apply as per manufacturer's instructions. For use with water up to 85°C.
'Jinghong-MAG (also known as Jinhong-Mag)'. Sintered ferrite magnetic washer encapsulated in a grey coloured Parylene film. For use with water up to 50°C.
'Hydropriv PE100 Pipe'. Black coloured (with blue external stripes), extruded PE100 pipe. In January 2024, blue coloured, extruded PE100 'Hydropriv PE100 Pipe' was added to the approval. Both pipes are for use with water up to 23°C.
'PE002'. Blue coloured, extruded HDPE pipe. Between May 2020 and 2nd December 2021, the pipe was for use with water up to 23°C. Between 3rd December 2021 and 31st May 2025, the pipe is for use with water up to 60°C.
'Plastazote LD15 to LD70'. Extruded, LDPE foams available in natural (appears white coloured) or black. 'Plastazote HD30 to HD110'. Extruded, HDPE foams available in natural (appears white coloured) or black. 'Evazote EV30 to EV50'. Extruded, EVA foams available in natural (appears white coloured) or black. For use with water up to 50°C. From January 2023, the following grades are for use with water up to 85°C: ‘LD70, Plastazote HD30 to HD110' & Evazote EV30 to EV50'.
'Fortron ICE 504L SD 3039 black (DW)'. Black coloured, injection moulded PPS material. For use with water up to 85°C.
'LARTON G/40 NAT.:0169F1'. Brown coloured, injection moulded PPS material. For use with water up to 85°C.
'TTD10'. White coloured (opaque), extruded PTFE tape. For use with water up to 85°C.
'Chemfix CH+'. Grey coloured, two-component chemical anchor resin. Mix in a 10:1 volume ratio. Apply as per manufacturer's instructions dated 05/07/2014. Cure for 7 days@7°C. For use with water up to 23°C. For use only as a resin anchor having been tested at a reduced surface area to volume ratio of 1,000mm² per 1 litre of water. This material is only approved for the mixing and curing conditions that appear on the approval. If the mix and cure conditions are varied from those specified on the approval then the material is not covered by the scope of the approval.
'EP60/1 BLK'. Black coloured, compression moulded EPDM diaphragm seal. Shore hardness 60. Tested in-radius size 0.75mm. For use with water up to 85°C.
'EP70 Black EPDM Diaphragm Seals'. Black coloured, compression moulded EPDM diaphragm seals. Shore hardness 70. Tested in-radius size 1,0mm. For use with water up to 85°C.
'EP1/1/5 BLK EPDM Diaphragm'. Black coloured, compression moulded EPDM diaphragm. Shore hardness 70. Tested in-radius size 0.65mm. For use with water up to 85°C.
'EP6700 (shore hardness 67), EP7500 (shore hardness 75) & EP8300 (shore hardness 83)'. Black coloured, compression moulded EPDM materials. Tested in-radius size 0.97mm. For use with water up to 23°C
'0530.19.V.X BELL'. Black coloured, compression moulded FKM seal. Shore hardness 70. Tested in-radius size 4.6mm. For use with water up to 23°C.
'NBR 70 M066'. Black coloured, injection moulded NBR 'O' ring. Shore hardness 70. Tested in-radius size 3.0mm. For use with water up to 23°C.
'01/B80NBR 'O' rings' and gaskets. Black coloured, injection moulded NBR 'O' rings and gaskets. Shore hardness 80. Tested in-radii sizes between 0.5mm & 2.0mm. For use with water up to 23°C.
‘ELASTOSIL® R’ solid silicone rubber materials. The number in brackets indicates shore hardness. Tested in-radius size 1.0mm. The following grades are natural and are for use with water up to 85°C. E indicates ELASTOSIL® AUX Crosslinker E. C1 indicates ELASTOSIL® AUX Crosslinker C1. Grades for extrusion and press moulding: R 401/20 E (shore hardness 20), R 401/30 E (30), R 401/40 E (40), R 401/50 E (50), R 401/55 E (55), R 401/60 E (60), R 401/70 E (70), R 401/80 E (80) & R 401/90 E (90). R 402/60 E (shore hardness 60), R 401/65 E (65) & R 401/75 E (75). R 420/30 E (shore hardness 30), R 420/40 E (40), R 420/50 E (50), R 420/60 E (60) & R 420/70 E (70). Grades for press moulding: R 401/20 C1 (shore hardness 20), R 401/30 C1 (30), R 401/40 C1 (40), R 401/50 C1 (50), R 401/55 C1 (55), R 401/60 C1 (60), R 401/70 C1 (70), R 401/80 C1 (80) & R 401/90 C1 (90). R 402/60 C1 (shore hardness 60) & R 402/75 C1 (75). Grades for press moulding added November 2022: R 420/30 C1 (shore hardness 30), R 420/40 C1 (40), R 420/50 C1 (50), R 420/60 C1 (60) & R 420/70 C1 (70). R 420/30 C1 & R 420/70 C1. The products may be coloured using the following ELASTOSIL® pigment pastes, also for use with water up to 85°C: PT Yellow RAL 1021. PT Red RAL 3000 F. PT Red brown RAL 3013. PT Light brown RAL 8003. PT Dark brown RAL 8015. PT Green RAL 6017. PT Ultramarineblue RAL 5002. PT Light blue RAL 5015. PT Grey RAL 7040. PT Carbon black RAL 9005. PT Black RAL 9017. PT White RAL 9010. ELASTOSIL® pigment pastes, for use with water up to 85°C added November 2022: PT Yellow RAL 1016.
ELASTOSIL® LR liquid silicone rubber material. The number in brackets indicates shore hardness. Tested in-radius size 0.8mm. The following grades are natural and are for use with water up to 85°C. Grades for injection moulding: LR 3071/40-60 A & B (40 - 60). LR 3003/10-80 A & B (10 - 80). LR 3004/20-70 A & B (20 - 70). The products may be coloured using the following ELASTOSIL® pigment pastes, also for use with water up to 85°C: FL yellow RAL 1016. FL orange RAL 2004. FL Red Brown RAL 3013. FL dark blue RAL 5010 & FL light blue RAL 5015. FL grey RAL 7000. FL carbon black RAL 9005. FL black RAL 9011. FL white RAL 9010. FL Red RAL 3000 F. FL Orange 2004 F. FL Light Blue 5015 F. FL Black 9005 F. FL green RAL 6010. ELASTOSIL® R plus platinum catalysed HTV silicone rubber. The number in brackets indicates shore hardness. Tested in-radius size 0.8mm. The following grades are natural and are for use with water up to 85°C. Grades for injection and press moulding: R plus 4001/40-80 (40 - 80). Grades for extrusion: R plus 4305/40-80 (40 - 80). The products may be coloured using the following ELASTOSIL® pigment pastes, also for use with water up to 85°C: PT yellow RAL 1016. PT orange RAL 2004. PT dark blue RAL 5010 & PT light blue RAL 5015. PT carbon black RAL 9005. PT white RAL 9010.
'WEICONLOCK AN 306-20'. Green coloured anaerobic adhesive. For use with water up to 85°C. This product is to be applied and cured in strict accordance with the manufacturer's instructions
Range of single hole, single outlet (fixed) electronically controlled tap assemblies (either stainless steel or brass bodies in a variety of finishes). Flow is controlled via two solenoid valves (housed in a control box) activated via an infra-red sensor, the inlets to the control box incorporate stainless steel strainers. The temperature is controlled independently via a ceramic cartridge with a dome type operating member. The spout outlet incorporates a plastic aerator. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.
BS1212-4 (2016) compact type float operated valve for WC flushing cisterns, bottom entry type with plastic ½’’ BSP inlet. The inlet incorporates a stainless steel strainer and a plastic flow restrictor. Cold water use only. Maximum working pressure10.0 bar
Rainwater harvesting back up device used to top up rainwater harvesting tanks with mains water. The device is fed by a solenoid valve and discharges via a type `AB` airgap (verified by test - suitable for backflow protection against fluid category 5). Maximum working pressure 10.0 bar. Cold water use only.
Range of double check valve assemblies consisting of two spring loaded in-line check valve cartridges housed in a DZR brass body with a drain port between the cartridges. Maximum working pressure 10.0 bar. Maximum operating temperature 85°C.
Non-verifiable double check valve assembly with DZR brass or chrome plated body, incorporating two spring loaded, resilient trim in-line check valve cartridges. Maximum working pressure 10.0 bar. Maximum operating temperature 100°C.
Commercial pasta cooker. Flow is controlled by a solenoid valve and discharges via a stainless-steel spout outlet Maximum working pressure 3.0 bar. Cold water supply only.
Single hole, single outlet (fixed) over the rim bidet combination tap assembly (various finishes). Incorporating ceramic cartridge and single lever operating members. The spout outlet incorporates a plastic aerator and the product is supplied with a pop-up waste. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.
Single hole bidet tap with brass body (various finishes) swivel spout outlet and a ceramic disc headwork (various operating members). The outlet incorporates an aerator and the product is supplied with a pop-up waste. Maximum working pressure 3.5 bar. Maximum operating temperature 60°C.
Range of ceramic cartridge assemblies with plastic bodies for insertion into specifically dimensioned bodies. Maximum working pressure 10.0 bar. Maximum operating temperature 85°C
Range of ceramic disc diverter cartridges with flow control having plastic bodies for use in specifically dimensioned bodies. Maximum working pressure 16.0 bar. Maximum operating temperature 85°C
Non rising spindle headwork with EPDM seals and brass body. For insertion into specifically dimensioned tap assemblies. Maximum working pressure 10.0 bar. Maximum operating temperature 85°C
Two way ceramic disc headwork with a plastic body and EPDM ‘O’-rings. For insertion into specifically dimensioned bodies. Maximum working pressure 10.0 bar. Maximum operating temperature 85°C.
Ceramic cartridge headwork (sequential) incorporating a plastic body and silicone seals. For insertion into specifically dimensioned tap assemblies. Maximum working pressure 5.0 bar. Maximum operating temperature 85°C.
Range of ceramic cartridge headworks with a plastic body and NBR seals to be housed in specifically dimensioned bodies. Maximum working pressure 12.0 bar. Maximum operating temperature 85°C.
Range of ceramic cartridge headworks with plastic bodies and EPDM ‘O’-rings. For insertion into specifically dimensioned tap assemblies. Maximum working pressure 12.0 bar. Maximum operating temperature 85°C.
Thermostat with a wax senor having a brass body and stainless steel guide. For insertion into specifically dimensioned bodies. Maximum working pressure 16.0 bar. Maximum operating temperature 85°C
Range of thermostatic mixing cartridges with plastic bodies incorporating NBR ‘O’-rings and stainless-steel filters, for insertion into specifically dimensioned bores. Maximum working pressure 5.0 bar. Maximum operating temperature 85°C.
Thermostatic cartridge with a plastic body, silicone ‘O’-rings and stainless-steel filters. For insertion into specifically dimensioned bores. Maximum working pressure 3.0 bar. Maximum operating temperature 85°C.
Single hole single outlet (swivel) pull out spray combination tap assembly (chromium plated brass) with ¼ turn ceramic disc headwork and single lever operating members. The spout outlet incorporates a plastic flow aerator and an approved check valve cartridge however, the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum working pressure 10.0 bar. Maximum operating temperature 70°C.
Single hole, single outlet (swivel) combination tap assemblies (chromium plated brass). Incorporating ceramic cartridge headworks and single lever operating member. The flexible spout outlet incorporates a plastic aerator and an approved check valve cartridge, however, the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.
Range of single hole, single outlet (fixed) combination tap assemblies with brass bodies (various finishes) incorporating a ceramic cartridge headwork with a single lever operating member. The spout outlet incorporates a plastic aerator. Maximum operating pressure 5.0 bar. Maximum operating temperature 60°C.
Range of single hole, single outlet fixed combination tap assemblies (chromium plated brass), incorporating a ceramic cartridge headwork with a single lever operating member. The spout outlet incorporates a plastic aerator (COB BAS C) or flow straightener (COB SMBAS C). Model COB BAS C is supplied with a click type waste. Maximum operating pressure 5.0 bar. Maximum operating temperature 60°C.
Single hole, single outlet fixed combination tap assemblies (chromium plated brass), incorporating a ceramic cartridge headwork with a single lever operating. The spout outlet incorporates a flow straightener. Maximum operating pressure 5.0 bar. Maximum operating temperature 60°C
Single hole, single outlet fixed combination tap assemblies (chromium plated brass), incorporating a ceramic cartridge headwork with a single lever operating member. The spout outlet incorporates a plastic aerator. Product is supplied with a click type waste. Maximum operating pressure 5.0 bar. Maximum operating temperature 60°C.
Single hole, single outlet (fixed) combination tap assembly (chromium plated brass), incorporating a ceramic cartridge headwork with a single lever operating member. The spout outlet incorporates a plastic flow straightener. Maximum operating pressure 5.0 bar. Maximum operating temperature 65°C.
Single hole, single outlet (fixed) combination tap assembles with brass bodies (various finishes), incorporating ceramic cartridge headworks with single lever operating member. The spout outlet incorporates a plastic aerator. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.
Range of single hole, single outlet (fixed) combination tap assemblies with brass bodies (various finishes), incorporating ceramic cartridge headworks with single lever operating members. The outlet incorporates a plastic aerator. Some models are supplied with a pop up or click type waste, see model.
Range of single hole, single outlet (fixed) combination tap assemblies with brass bodies (chromium plated or unlaquered brass), incorporating ceramic cartridge headworks and single lever operating members. The outlets incorporates a plastic aerator. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.
Range of single hole, single outlet (fixed) combination tap assemblies (chromium plated brass) incorporating ceramic cartridge headwork, and single lever operating members. The spout outlets incorporate a plastic flow straightener. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.
Single hole, single outlet (fixed) combination tap assembly (chromium plated brass), incorporating ceramic cartridge headwork with single lever operating members. The spout outlet incorporates a plastic flow straightener and the product is supplied with a click waste. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.
Single hole, single outlet (fixed) combination tap assembly (chromium plated brass), incorporating a ceramic cartridge headwork with a single lever operating member. The spout outlet incorporates a plastic flow straightener. The product is supplied with a click type waste. Maximum working pressure 10 bar. Maximum operating temperature 70°C.
Range of single hole, single outlet (fixed) combination tap assemblies with brass bodies (various finishes - see model), incorporating a ceramic cartridge headwork with either a single lever or dome type operating member. The spout outlet incorporates an aerator. The product can be supplied with a pop-up waste (see model). Maximum working pressure 10.0 bar. Maximum operating temperature 65°C
Deck mounted drinking fountain tap having a stainless steel body with an integeral shroud over the outlet. Outlet incorporates a stainless steel cover and strainer. Maximum working pressure 10.0 bar. Maximum operating temperature 85°C.
Range of single hole, single outlet (swivel) combination tap assemblies incorporating a brass body (chrome, nickel or black finish) and ceramic cartridge headworks with single lever operating members. The spout outlets incorporate a plastic aerator. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.
Range of single hole, single outlet (swivel) combination tap assemblies (chromium plated or brushed nickel brass), incorporating a ceramic cartridge headwork with a single lever operating member. The spout outlet incorporates a plastic flow straightener. Supplied with a combined isolation valve and single check valve assembly (suitable for Fluid Category 2) for both inlets. Maximum working pressure 5.0 bar. Maximum operating temperature 65°C.
Range of single hole, single outlet (swivel) combination tap assemblies (chromium or gold plated brass), incorporating quarter turn ceramic disc headworks with cross top operating members. The spout outlet incorporates a plastic flow straightener. Supplied with a combined isolation valve and single check valve assembly (suitable for Fluid Category 2) for both inlets. Maximum operating pressure 5.0 bar. Maximum operating temperature 65°C.
Range of single hole, single outlet (swivel) combination tap assemblies (chromium or gold plated brass), incorporating non-rising spindle headworks with cross top operating members. The spout outlet incorporates a plastic flow straightener. Supplied with a combined isolation valve and single check valve assembly (suitable for Fluid Category 2) for both inlets. Maximum working pressure 5.0 bar. Maximum operating temperature 65°C
Single hole, single outlet (swivel) combination tap assembly (chromium plated brass), incorporating ceramic cartridge headwork and single lever operating member. The spout outlet incorporates a plastic aerator. The cold water inlet tail incorporates approved check valve cartridge, however, the complete product has not been fully tested to demonstrate it provides backflow protection Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.
Range of single hole, single outlet (swivel) combination tap assemblies with brass bodies (chromium plated), incorporating quarter turn ceramic disc headworks with single lever operating members. The spout outlets incorporates a plastic flow straightener. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.
Range of single hole, single outlet (swivel) combination tap assemblies with brass bodies (chromium plated), incorporating ceramic cartridge headworks and single lever operating member. The connection to flexible hose and spray outlets incorporates an approved single check valve cartridge (however, the whole product has not been fully tested to demonstrate that it provides adequate backflow protection) the outlets incorporates a plastic aerator. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.
Range of single hole, single outlet (swivel) combination tap assemblies with brass bodies (various finishes) incorporating a ¼ turn ceramic disc headwork supplied with single lever operating members. The spout outlet incorporates a plastic flow straightener. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.
Single hole, single outlet (swivel) combination tap assembly (chromium plated brass), incorporating a ceramic cartridge headworks, and single lever operating members for the flow of domestic hot or cold water. The products incorporate a touch / sensor option via the spout or base and is controlled via a solenoid valve. The touch flow control handle is used to adjust the flow rate and will run for approximately 30 seconds. The spout includes a ‘grab’ function which allows the spout to be moved without activating the sensor. The spout outlet incorporates a plastic aerator and the product is supplied with a pop-up waste. Inlets incorporate approved check valve cartridges however, the complete product has not been fully tested to demonstrate it provides backflow protection, fitted within chromium plated brass adaptors. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C
Range of single hole, single outlet (swivel) combination tap assemblies incorporating a brass body (chrome, nickel or black finish) and ceramic cartridge headworks with single lever operating members. The spout outlets incorporate a plastic aerator. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.
Range of single hole, single outlet (swivel) combination tap assemblies (various finishes), incorporating a ceramic cartridge headwork with a single lever operating member. The spout outlets incorporate a plastic aerator and an on/off button which can stop the flow of water. The inlets incorporate approved check valve cartridges, however, the complete product has not been fully tested to demonstrate it provides backflow protection Maximum working pressure 10.0 bar. Maximum operating temperature 70°C.
Range of single hole, single outlet (swivel) combination tap assemblies (chromium plated brass). Incorporating ceramic cartridge headworks and single lever operating members. The spout outlets incorporate a plastic aerator. Maximum working pressure 5.5 bar. Maximum operating temperature 60°C.
Range of single hole, single outlet (swivel) combination tap assemblies (chromium plated brass). Incorporating non-rising spindle headworks with dome type or cross top operating members. Both models are supplied with a plastic flow straightener. Maximum working pressure 10.0 bar. Maximum operating temperature 70°C.
Single hole, single outlet (swivel) combination tap assembly (chromium plated brass). Incorporating quarter turn ceramic disc headworks and single lever operating members. The spout outlet incorporates a plastic aerator. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.
Range of single hole, single outlet (swivel) combination tap assemblies (chromium plated brass). Incorporating quarter turn ceramic disc headwork with single lever operating members. The inlets incorporate a plastic strainer and an approved check valve cartridge, however, the complete product has not been fully tested to demonstrate it provides backflow protection The spout outlet incorporates a plastic aerator. Maximum working pressure 5.5 bar. Maximum operating temperature 60°C
Single hole, single outlet (swivel) combination tap assembly (chromium plated brass). Incorporating quarter turn ceramic disc headworks and single lever operating members. The spout outlet incorporates a plastic aerator. Inlets to the flexible inlet hoses incorporate single check valves (however the complete assembly has not been tested to demonstrate it provides adequate backflow protection). Maximum working pressure 5.5 bar. Maximum operating temperature 60°C.
Range of single hole, double outlet (swivel) combination tap assemblies (chromium plated or white painted brass), incorporating quarter turn ceramic disc headworks and single lever type operating members. Outlets incorporates a plastic flow straightener. Maximum operating pressure 10.0 bar. Maximum operating temperature 70°C.
Range of single hole, double outlet (swivel) combination tap assemblies with brass bodies (various finishes) incorporating a quarter turn ceramic disc headwork and single lever operating members. The spout outlet incorporates a plastic flow straightener. Maximum working pressure 10.0 bar. Maximum operaring temperature 60°C.
Range of two-hole, metal, single outlet (fixed) combination tap assemblies with brass bodies (various finishes) incorporating quarter turn ceramic disc cartridge headwork with single lever operating members. The outlets incorporate a plastic aerator and the products are supplied with metal back nuts. Maximum working pressure 5.0 bar. Maximum operating temperature 60ºC.
Two hole, single outlet fixed combination tap assembly (chromium plated brass) incorporating quarter turn ceramic disc headworks with single lever operating members. The spout outlet incorporate a plastic flow straightener and the product is supplied with metal back nuts. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.
Two hole, single outlet (fixed) combination tap assembly (chromium plated brass) incorporating quarter turn ceramic disc headworks with single lever operating members. The spout outlet incorporates a plastic flow straightener. The product is supplied with metal back nuts. Maximum working pressure 5.0 bar. Maximum operating temperature 65°C.
Range of two hole, single outlet (fixed) combination tap assemblies incorporating brass bodies (various finishes), ceramic cartridge headworks and single lever operating members. The spout outlets incorporates a plastic aerator. Fittings are supplied with metal backnuts. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.
Two hole, single outlet (fixed) combination tap assembly (chromium plated brass) incorporating quarter turn ceramic disc headwork with single lever type operating members and a manually operated diverter to shower outlet. The spout outlet incorporates a plastic aerator and the product is also supplied with a shower handset and hose. The inlet of the shower handset incorporates a plastic flow regulator. The product is supplied with either plastic or metal backnuts. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.
Range of two hole, single outlet (fixed) combination tap assemblies (various finishes). Incorporating quarter turn ceramic disc headworks with single lever, dome or cross top operating members and manual diverters to shower outlets. The spout outlets incorporate plastic flow straighteners. This approval includes a hose, handset and wall bracket and the products are supplied with plastic backnuts. Maximum working pressure 6.0 bar. Maximum operating temperature 60°C.
Two hole metal single outlet (fixed) combination tap assembly (chromium plated brass) incorporating quarter turn ceramic disc headwork with single lever operating members and a self-cancelling diverter to shower outlet. The spout outlet incorporates a plastic flow straightener and the product is supplied with metal backnuts, hose and handset. Maximum working pressure 10.0 bar. Maximum operating temperature 70°C.
Two hole, single outlet (fixed) combination tap assembly with brass body (various finishes). Incorporating quarter turn ceramic disc headworks with single lever, dome or cross top operating members and self canceling diverter to shower outlet. The spout outlets incorporate plastic flow straighteners. This approval includes a hose, handset and wall bracket and the products are supplied with plastic backnuts. Maximum working pressure 6.0 bar. Maximum operating temperature 60°C.
Range of two hole, single outlet (fixed) combination tap assemblies (various finishes). Incorporating ceramic disc headworks, single lever operating members and self-cancelling diverter to shower outlet. The spout outlet incorporates a plastic flow straightener. The products are supplied with a shower hose, shower handset and plastic back nuts. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.
Single hole, single outlet, swivel combination tap assembly (chromium plated brass) incorporating ¼ turn ceramic disc headworks with single lever operating members. The spout outlet incorporates a plastic aerator. Maximum working pressure 5.0 bar. Maximum operating temperature 60 °C.
Wall mounted two-hole, single outlet (swivel) combination tap assembly (stainless steel), incorporating quarter turn ceramic disc headworks with handwheel operating members. The spout outlet incorporates a plastic aerator. Each inlet incorporates an approved check valve cartridge, however, the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.
Two hole, single outlet (fixed) combination tap assemblies with brass bodies (various finishes). Incorporating quarter turn ceramic disc headworks, single lever operating members and self cancelling lockable diverter to shower outlet. The spout outlet incorporates a plastic aerator and the product is supplied with metal backnuts. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.
Range of deck mounted, three-hole, single outlet (fixed) combination tap assemblies incorporating brass bodies (various finishes) and quarter turn ceramic disc headwork WITH single lever operating members. The spout outlets incorporate a plastic aerator. The headwork is connected to the spout via stainless steel braided, EPDM lined flexible hoses. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.
Range of three-hole, single outlet (fixed) combination tap assemblies (various finishes), incorporating quarter turn ceramic disc headworks with single lever operating members. The spout outlets incorporate a plastic aerator. The headwork is connected to the spout via stainless steel braided, EPDM lined flexible hoses. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C
Three-hole, single outlet (fixed) combination tap assembly (chromium plated brass) incorporating non-rising spindle headworks with cross top operating members. The spout outlet incorporates a plastic flow straightener or optional plastic aerator. The product is supplied with metal backnuts, lever operated pop-up waste and stainless steel braided PEX lined flexible hose assemblies intended for connection between the valves and spout. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C
Wall mounted three hole, single outlet (fixed) combination tap assembly incorporating a concealed brass body and chrome plated trim set with a quarter turn ceramic disc headwork and dome type operating members. Spout outlet incoprorates a plastic aerator. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.
Range of deck mounted three hole, single outlet (fixed) combination tap assemblies with brass bodies (various finishes), incorporating quarter turn ceramic disc headworks and single lever operating members. Interconnecting hoses are stainless steel braided EPDM lined flexible hoses. The spout outlet incorporates a plastic aerator. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.
Range of three hole, single outlet (fixed) combination tap assemblies (chromium plated brass), incorporating quarter turn ceramic disc headworks and single lever operating members. The brass connecting tee between the inlet hoses and supply to the spout outlet is fitted with single check valve assemblies however, the complete assembly has not been tested to demonstrate it provides adequate backflow protection. The spout outlet incorporates a plastic aerator, ½” connectors and some models are supplied with a pop-up waste. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.
Range of wall mounted concealed three hole, single outlet (fixed) combination tap assemblies (chromium plated brass). Incorporating quarter turn ceramic disc headworks and various operating members. The spout outlets incorporate a plastic aerator. The inlet to the spout incorporates a flow regulator. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.
Wall mounted bath spout incorporating a brass body (various finishes) and a plastic aerator. Maximum operating temperature 60°C.
Wall mounted spout outlet (various finishes, see model) incorporating a plastic flow straightener. Maximum operating temperature 60°C.
Macerator with flow controlled by solenoid valve and discharged via a type `AB` airgap (verified by test - suitable for backflow protection against fluid category 5). Maximum working pressure 6.0 bar. Maximum operating temperature 60°C.
Expansion vessel incorporating a Bromobutyl membrane with noryl connection disc. Maximum working pressure 12.0 bar. Cold water use only.
Range of in-line water filters (cartridge and head) with plastic bodies and EPDM ‘O’ rings. The A 1000 model incorporates an approved check valve cartridge however, the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum working pressure 8.6 bar. Cold water use only.
Range of clamp fittings incorporating DZR brass bodies, EPDM ‘O’-rings. For use with Uponor PE 100 RC pipe to EN12201 only. Maximum working pressure 16.0 bar. Maximum operating temperature 20°C.
Range of copper solder ring fittings for use with EN 1057 copper tube. For above ground use only. Maximum working pressure 16.0 bar. Maximum operating temperature 85°C.
Range of brass and DZR brass compression fittings for use with copper tube to EN1057. Maximum working pressure 16.0 bar. Maximum operating temperature 85°C.
Range of DZR brass push fit fittings for use with copper pipe, PB pipe (manufactured to BS7291-2) & PEX pipe (manufactured to BS7291-3). When used with copper pipes the maximum working pressure is 16.0 bar. When used with plastic pipes the maximum working pressure is 6.0 bar. Maximum operating temperature 95°C.
Range of urinal flushing mechanisms with a solenoid valve controlling the flow. The valves are controlled via an infra-red sensor. Maximum working pressure 6.0 bar. Cold water use only.
Range of floor standing commercial glass washers incorporating a solenoid valve controlling the flow. The product is supplied with a double check valve assembly (suitable for backflow protection against fluid category 3). Maximum working pressure 4.0 Bar. Maximum operating temperature 60°C.
Range of stainless steel plate heat exchangers. The product incorporates a stub pipe with a ½” BSP (F) end connection on the secondary flow (outlet) which can accommodate a control sensor and strap on limit thermostat, (neither of which are supplied or considered part of the approval listing). Maximum working pressure 10.0 bar. Maximum working temperature 85°C.
Type "J" range of plate heat exchangers with stainless steel (AISI 304L) bodies and copper welding. Maximum working pressure 3.0 bar (Primary Circuit) and 10.0 bar (Secondary Circuit). Maximum operating temperature 80°C.
Range of ‘HYCO’ electric instantaneous water heaters with plastic bodies, NBR and silicone ‘O’-rings. The inlet of model IN96T incorporates a plastic strainer. Maximum working pressure 7.5 bar. Maximum operating temperature 60°C.
‘Hydraulic Block 2’ range of integrated water circuits for use with combination boilers comprising of a plastic body, stainless steel thermistors and a plate heat exchanger. The primary circuit incorporates a pump assembly. Maximum working pressures: Primary Circuit 2.5 bar. Secondary Circuit 10.0 bar. Maximum operating temperatures: Primary circuit 85˚C. Secondary circuit 65°C. Cold supply only.
Range of ultrasonic water meters with plastic bodies, EPDM rubber ‘O’-rings and the inlet incorporates a plastic strainer. Maximum working pressure 16.0 bar. Maximum operating temperature 50°C.
Water meter with a brass body, NBR ‘O’-rings and EDPM washers. The inlet incorporates a plastic strainer. Maximum working pressure 16.0 bar. Cold water use only.
In-line plastic flow regulator housed within a brass body (chrome plated) or stainless steel body (HL2024 Cradle model only) incorporating a plastic strainer and EPDM ‘O’-rings. HL2024 Inline 1P BSP threaded models also have NBR/fibre gaskets. Maximum working pressure 10.0 bar. Maximum operating temperature 90°C.
Plastic bodied flow sensor. Maximum working pressure 10.0 bar. Maximum operating temperature 85°C.
Ceiling mounted shower arm with brass bodies (various finishes) and faceplate. Maximum operating temperature 85°C.
In-wall concealed, manually accessible and operated hose connector incorporating a brass body, quarter turn ceramic disc headwork and operated by removable key. Maximum working pressure 10.0 bar. Maximum operating temperature 85°C.
Helix range of vertical stainless steel multistage pumps with various pump housing materials depending on pump configuration. Maximum working pressure 30.0 bar. Cold water use only.
VDROO range of stainless steel multistage centrifugal pumps with stainless steel impellers, diffusers and outer sleeves. The pumps incorporate a Silicone Carbide and EPDM mechanical seal. Maximum working pressure 25.0 bar DIN flange. Maximum working pressure 16.0 bar for oval flange. Cold water use only.
Range of pumps incorporating a plastic body with stainless steel impellers, shaft and chambers. The inlet incorporate a stainless steel strainer. Maximum working pressure 2.4 bar (model HQ200). Maximum working pressure 3.1 bar (model HQ400). Maximum working pressure 3.3 bar (model HQ800). Cold water use only.
Range of stainless steel shower outlets with NBR ‘O’-rings. Maximum operating temperature 60°C.
Stainless steel shower outlet with a swivel connection. Maximum operating temperature 65°C.
Range of ceiling mounted shower arms with brass bodies (various finishes) Maximum operating temperature 85°C
Range of shower outlets with chromium plated metal or plastic bodies some models include a shower hose. Inlets incorporate a stainless steel strainer and flow restrictors. SJK23 incorporates a stainless-steel anti-tamper device at the inlet. Maximum operating temperature 60°C.
Range of shower arms having brass bodies (various finishes) incorporating a threaded connection at the outlet and EPDM ‘O’-rings. Maximum operating temperature 70°C.
Ranges of overhead shower outlets with brass bodies (various finishes), stainless steel strainers and NBR ‘O’-rings. Maximum operating temperature 85°C.
Range of overhead shower outlets with stainless steel bodies (various finishes - see model). The inlet incorporates a combined EPDM washer and stainless steel strainer and an approved check valve cartridge, however, the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum operating temperature 80°C.
Wall mounted angled shower outlet with a brass body (various finishes) and NBR ‘O’-rings. The wall outlet and the inlet of the shower handset both incorporate an approved check valve cartridge, however, the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum working temperature 60°C.
Range of shower outlets/arms (chromium plated brass or chromium plated ABS bodies). Maximum operating temperature 65°C.
Range of brass shower arms and plastic shower heads (various finishes) incorporating EPDM seals and ‘O’-rings, silicone seals and spray insert. The 26 469 xxx model is ceiling mounted & 26 470 xxx model is wall mounted. Both models incorporate a swivel joint housing a plastic flow regulator. Maximum operating temperature 60°C.
Range of interlocked EPDM lined shower hoses assemblies with EPDM gaskets. Maximum operating temperature is 85°C. bar.
Range of Y type strainers with epoxy coated cast iron bodies and stainless steel strainers. Maximum working pressure 16.0 bar. Maximum operating temperature 85°C.
Range of in-line `Y`-patterned strainers with bronze bodies incorporating stainless steel mesh strainers and PTFE washers. Maximum working pressure 20.0 bar. Maximum operating temperature 85°C.
Range of in-line `Y`-patterned strainers with bronze bodies incorporating stainless steel mesh strainers and PTFE washers. Maximum working pressure 20.0 bar. Maximum operating temperature 85°C.
Range of in-line `Y`-patterned strainers with bronze bodies incorporating stainless steel mesh strainers and PTFE washers. Maximum working pressure 20.0 bar. Maximum operating temperature 85°C.
Range of Y-pattern strainers with DZR brass bodies and stainless steel strainers. Maximum working pressure 20 bar (BSP threaded models ½”-2”), 16.0 bar (BSP threaded models 2½”-3” and compression models). Maximum operating temperature 85°C.
Test Point incorporating a brass body and EPDM ‘O’-ring and seals. Maximum working pressure 20.0 bar. Maximum operating temperature 99°C.
Range of pillar taps (chromium plated brass) with quarter turn ceramic disc headwork and single lever operating members. The spout outlet incorporates a plastic flow straightener. The product is supplied with metal backnuts. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.
Range of pillar taps with brass bodies (chromium plated or gold effect finish), incorporating quarter turn ceramic disc headwork with single lever operating members. The spout outlets incorporates a plastic flow straightener and the product is supplied with plastic backnuts. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.
Pillar tap with brass body (chromium plated or gold effect finish), incorporating quarter turn ceramic disc headwork with single lever operating members. The spout outlets incorporates a plastic flow straightener and the product is supplied with plastic backnuts. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.
Range of pillar taps (chromium plated brass) with non-rising spindle or quarter turn ceramic disc headworks and dome type or cross top operating members. The spout outlets incorporates a plastic flow straightener. Products are supplied with metal backnuts. Maximum working pressure 10.0 bar. Maximum operating temperature 85°C.
Range of pillar taps (chromium plated brass) with non-rising spindle headworks or quarter turn ceramic disc headworks and dome type or cross top operating members. The spout outlets incorporates a plastic flow straightener. Products are supplied with metal backnuts. Maximum working pressure 10.0 bar. Maximum operating temperature 85°C.
Range of pillar taps with brass bodies (various finishes), incorporating quarter turn ceramic disc headworks with single lever operating members. Spout outlets incorporate a plastic flow straightener. Maximum working pressure 10.0 bar. Maximum operating temperature 65°C.
Range of pillar taps with brass bodies (various finishes), incorporating quarter turn ceramic disc headwork with single lever operating members. The spout outlets incorporate plastic flow straighteners and the products are supplied with plastic backnuts. Maximum working pressure 10.0 bar. Maximum operating temperature 65°C.
Range of bath pillar taps with brass bodies (various finishes). Incorporating a non-rising spindle headworks with various operating members. The spout outlets incorporates a plastic flow straightener. The product is supplied with either metal or plastic back nuts. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.
Range of basin pillar taps with brass bodies (various finishes). Incorporating a non-rising spindle headworks with various operating members. Spout outlets incorporate a plastic flow straightener. Products are supplied with either plastic or metal backnuts. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.
Deck mounted self-closing basin tap (chromium plated brass), incorporating a non-concussive headwork with either a dome type operating member (QK23051 ATI model) or a joystick style operating member (QL23051 ATI model). The spout outlet incorporates a plastic flow straightener. The products are supplied with metal back-nuts. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.
Range of shower hoses incorporating a PVC inner liner with corrugated metal outer casing, EPDM washers and stainless steel strainer. Maximum operating temperature 60°C.
Range of interlocked, chrome plated, stainless-steel shower hoses incorporating EPDM washers and a polyethylene liner. Maximum operating temperature 70°C.
Range of flexible hoses assemblies incorporating a braided outer with TPSiV liner and various brass end connections. Incorporating NBR or EPDM washers and ‘O’-rings. Maximum operating temperature 85°C.
Lux range of DN18 stainless steel braided silicone lined hose assemblies with various brass end connections. Maximum working pressure 10.0 bar. Maximum operating temperature 70°C.
Solar range of auto air-vent valves (chromium plated brass) and a plastic float. Maximum working pressure 10.0 bar. Maximum operating temperature 100°C.
Concealed shower valve incorporating a stainless-steel body, ceramic cartridge headwork and single lever operating member. Supplied with a stainless steel overhead shower outlet incorporating a stainless steel strainer at the inlet. Maximum working pressure 8.0 bar. Maximum operating temperature 65°C.
Range of wall mounted shower valves (chromium plated brass) with a ceramic cartridge headwork and various operating members. Incorproating a cermic disc headwork that controls the flow and also diverts to an over head shower or hand shower outlet. Maximum working pressure 10.0 bar. Maximum operating temperature 70°C.
Wall mounted, exposed bar type shower mixer (chromium plated brass). Flow is controlled by a solenoid valve. Temperature is controlled independently via a thermostatic cartridge with dome type operating member that incorporates a manual override button. Inlets incorporate a stainless-steel strainer and an approved check valve cartridge however, the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum working pressure 10.0 bar. Maximum operating temperature 80°C
Range of wall mounted, bar-type thermostatic shower valves with brass bodies (chromium plated), incorporating a non-rising spindle headwork controlling the flow with a dome type operating member. Temperature is controlled independently via a thermostatic cartridge using a dome type operating member which incorporates a manual override button. Both inlets incorporate a stainless steel strainer and an approved check valve cartridge, however, the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum working pressure 10.0 bar. Maximum operating temperature 85°C.
Range of wall mounted, concealed thermostatic blending valve (brass bodies). Both inlets have stainless steel filters and incorporate an approved check valve cartridge (however, the complete product has not been fully tested to demonstrate it provides backflow protection). The product also incorporates a push button headworks and the temperature is controlled independently via a thermostatic cartridge. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.
Wall mounted concealed modular thermostatic mixing valve (brass body). The product is supplied with a shower hose and handset and incorporates additional outlet ports to supply shower outlet configuations controlled by push button flow control headworks. Primary flow control is via a half turn ceramic disc headwork and dome type operating member. The temperature is controlled independently via a thermostatic cartridge and dome operating member. Inlets incorporate stainless steel strainers and single check valve cartirgdes however, the complete product has not been fully tested to demonstrate it provides backflow protection Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.
Range of T-type thermostatic mixing valves (chromium plated brass). Each inlet incorporates a stainless steel strainer and a single check valve cartridge, however, the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum working pressure 10.0 bar. Maximum operating temperature 85°C.
Single hole, single outlet combination tap assembly (chromium plated brass) incorporating a sequential headworks with single lever operating member to control both the flow and temperature. The outlet incorporates a plastic flow straightener. The product also incorporates a single check valve assembly (verified by test as suitable for backflow protection against Fluid Category 2). Maximum working pressure 10.0 bar. Maximum operating temperature 60ºC.
Range of wall mounted, thermostatic shower valves with chromium plated brass body. Flow is controlled by a quarter turn ceramic disc headwork with single lever operating members. Temperature is controlled by a thermostatic cartridge with a dome type operating member which incorporates a manual override button. The inlets incorporate a stainless steel strainer and an approved check valve cartridge however, the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum working pressure 10.0 bar. Maximum operating temperature 70°C
Combined pressure and temperature relief valves with DZR brass bodies, stainless steel springs, nylon coated probe, EPDM diaphragm and silicone seat disc. The valves incorporate lever easing gear. The valves have a factory pre-set pressure of 7.0 or 10.0 bar (see model). Maximum operating temperature 85°C.
Exposed two way diverter valve (chromium plated brass) with a single lever operating member for diverting between two different shower outlets. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.
Diverter valve with a plastic body, ceramic discs & NBR ‘O’-rings. For insertion into specifically dimensioned bodies. Maximum working pressure 10.0 bar. Maximum operating temperature 85°C.
Range of 2-way ceramic disc diverters/headworks (2 on, 1 off) with a plastic body and NBR seals to be housed in specifically dimensioned bodies. Maximum working pressure 12.0 bar. Maximum operating temperature 85°C.
Flow control valve with a cylindrical brass body, stainless steel spring and thermostatic element. Maximum working pressure 10.0 bar. Maximum operating temperature 85°C
Range of thermostatic regulating valves, with stainless steel bodies and EPDM ‘O’-rings. Maximum working pressure 10.0 bar. Maximum operating temperature 99°C
Range of manually operated flow control valves with brass bodies and either ¼ turn or ½ turn ceramic disc headworks (see model). The products are available with trim sets and operating members in various finishes (see model). Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.
Range of spring loaded, resilient trim, non-return valves with brass bodies. Maximum working pressure 25.0 bar. Maximum operating temperature 85°C.
Range of pre-set pressure relief valves with gunmetal bodies, silicon diaphragms, and PTFE seat washers. Pre-set relief pressures: 0.3 bar to 10.5 bar. Maximum operating temperature 95°C.
Range of normally closed solenoid valves with brass bodies & EPDM diaphragms. Maximum working pressure; AC Coil, All – 16.0 bar. DC Coil (14W) 3/4” & 1” – 9.0 bar, ¼”, 3/8” and ½” – 12.0 bar. DC Coil (22W) All – 16.0 bar. Maximum operating temperature 85°C.
Normally closed solenoid valve incorporating a plastic body, EPDM diaphragm and ‘O’-rings. Maximum working pressure 5.0 bar. Maximum operating temperature 70°C.
Range of latching and non-latching, normally open (L282 models) and normally closed (L182 models) solenoid valves with either brass or stainless-steel bodies. Please refer to model for maximum working pressure. Maximum operating temperature 85°C.
Range of in-line latching solenoid valves with a brass body. Maximum working pressure 12.0 bar (L160P03 1.6mm model) and 9.0 bar (L160P03 2.3mm model). Maximum operating temperature 85°C.
Range of spherical valves incorporating DZR brass bodies & balls and PTFE seats. Maximum working pressure 6.0 bar. Maximum operating temperature 60°C
Spherical valve intended for use on sanitary inlet / outlet connections on boiler circuits, with a brass body and PTFE seat. Maximum working pressure 12.0 bar. Maximum operating temperature 85°C.
Screwdriver operated angled servicing valve with brass body, brass ball, PTFE seats and EPDM ‘O’-rings. Maximum working pressure 12.0 bar. Maximum operating temperature 85°C.
Range of lever and butterfly handle spherical valves with chrome plated brass bodies, chrome plated brass ball and PTFE seats. Maximum working pressure 40.0 bar. Maximum operating temperature 85°C.
Range of lever operated servicing valves for use with BS EN 1057 R250 half hard copper tube, incorporating brushed chromium plated DZR brass bodies and ball, and PTFE seats. Maximum working pressure 16.0 bar. Maximum operating temperature 85°C.
Range of brass bodied or chrome plated brass bodied spherical valves, with a brass ball and EPDM ‘O’-rings. All fittings are to be used with PE-x pipe (manufactured to BS7291-3), PB pipe (manufactured to BS7291-2) and copper pipe. Maximum working pressure 10.0 bar. Maximum operating temperature 65°C.
Electrically actuated 3 way diverting valve incorporating brass bodies with NBR ‘O’-rings and PTFE seats. Maximum working pressure 16.0 bar. Maximum operating temperature 85°C.
Range of spherical valves incorporating brass bodies (various finishes) with EPDM ‘O’-rings or PTFE seats depending on model variant. Models can be straight or angled. Maximum working pressure 25.0 bar (models 10.61092.015.CP5R-8510 & 10.61092.015.CP12-8510). Maximum working pressure 16.0 bar (all other models). Maximum operating temperature 85°C.
Range of spherical valves incorporating UPVC or ABS bodies and EPDM seats. Maximum working pressure of sizes 3/8" - 2" and 16mm - 63mm is 16.0 bar. Maximum working pressure of sizes 2½" - 4" and 75mm - 110mm is 10.0 bar. Cold water use ony.
Range of ball valves incorporating brass bodies, stems & balls, PTFE seats and butterfly type or single lever operating members. Maximum working pressure 40.0 bar. Maximum operating temperature 95˚C.
Range of gate valves with DZR brass bodies and brass wedge. Valves are operated via a non-rising spindle headwork. Maximum operating pressure 20.0 Bar. Maximum operating temperature 100°C.
‘Z123’ range of gate valves with either brass or DZR brass (from October 2023) bodies and PTFE washers. Valves are operated via a non-rising spindle headwork. Maximum operating pressure 16.0 bar.
Non-metallic materials and components comply with BS6920 at 85°C
Range of screw down drain valves having brass bodies and EPDM ‘O’-rings, for use with EN1057 copper tube R250 half hard. Maximum working pressure 16.0 bar. Maximum operating temperature 85°C.
Range of front loading commercial washing machines with flow controlled by solenoid valve and discharged via a type `AB` airgap (verified by test - suitable for backflow protection against fluid category 5). The machines are supplied with double check valve assemblies. Maximum working pressure 10 Bar Maximum operating temperature 60°C
Range of hood type or undercounter commercial dishwashers. Flow is controlled by a solenoid valve which discharges via a type ‘AA’ air gap. Maximum working pressure 10.0 Bar. Cold water supply only.
Range of water conditioners with stainless steel or brass/copper alloy. Maximum working pressure 10.0 bar. Maximum operating temperature 100ºC.
'HP204AD'. Grey coloured, pressed & sintered, phenolic resin impregnated carbon bearing ring. For use with water up to 85°C.
'Birla SRPC - Electrocement'. Factory applied, grey coloured, cement mortar. Mix cement, sand & water in a mass ratio of 0.6:1.0:0.22. Cure for 24 hours@27°C. For use with water up to 60°C. This material is only approved for the mixing & curing conditions that appear on the approval. If the mix and/or cure conditions are varied from those specified on the approval then the material is not covered by the scope of the approval.
'Electrocement CEM1-SR3 - Dalmia SRPC'. Factory applied, grey coloured sulphate resisting Portland cement mortar. Mix cement, sand and water in a mass ratio of 0.6:1.0:0.22. Cure for 4 days at 26°C, and then at 32°C for a further 24 days OR 24 hours@27°C. For use with water up to 60°C. This material is only approved for the curing conditions that appear on the approval. If the cure conditions are varied from those specified on the approval then the material is not covered by the scope of the approval.
'Eurokote® 720 ES Bleu 5005'. Factory applied, blue coloured epoxy powder coating. Apply as per manufacturer's technical data sheet dated '01/04/2019'. Cure for 2 minutes@200°C. For use with water up to 85°C. This material is only approved for the mixing and curing conditions that appear on the approval. If the mix and/or cure conditions are varied from those specified on the approval then the material is not covered by the scope of the approval.
'NT-JW Standard Type'. Factory applied, grey coloured, two-component epoxy resin coating. Mix base and hardener in an 85:15 mass ratio and apply as per manufacturer's instructions. Cure for 18 hours@20°C. For use with water up to 23°C. This material is only approved for the mixing and curing conditions that appear on the approval. If the mixing and/or curing conditions are varied from those specified on the approval then the materials are not covered by the scope of the approval.
'NT-JW Low Temperature Type'. Factory applied, grey coloured, two-component epoxy resin coating. Mix base and hardener in an 85:15 mass ratio and apply as per manufacturer's instructions. Cure for 17 hours@10°C. For use with water up to 23°C. This material is only approved for the mixing and curing conditions that appear on the approval. If the mixing and/or curing conditions are varied from those specified on the approval then the materials are not covered by the scope of the approval.
'Kubotaseal BM'. Factory applied, black coloured asphaltic bituminous coating. Apply as per manufacturer's PDS reference `11004T-1.4' dated Feb, 20, 2020. Cure 6 hours@20°C. For use with water up to 60°C. Materials listed in this section are not approved for use for contact with water that is required to be wholesome on large water retaining structures such as lining of pipes, cisterns or water storage tanks. This material is only approved for the curing conditions that appear on the approval. If the cure conditions are varied from those specified on the approval then the material is not covered by the scope of the approval.
'SC3 Blue PTFE Coating'. Blue coloured, factory applied, PTFE coating intended to coat 'O' rings. Apply and cure as per manufacturer's instructions 'LDAP-007 issue 1' dated 11/02/2020. For use with water up to 85°C.
'Polyflon PTFE TC-7808-19 Grey PTFE Coating'. Factory applied, grey coloured PTFE coating. Apply as per manufacturer's technical data sheet dated 'June 8, 2012'. Cure for 20 minutes@380°C. For use with water up to 85°C. This material is only approved for the curing conditions that appear on the approval. If the cure conditions are varied from those specified on the approval then the material is not covered by the scope of the approval.
'ET-52184 & ET-52185'. Factory applied, grey coloured water-based silicone coating comprising of an under-coat (ET-52184) and finishing coat (ET-52185). Apply as per manufacturer's instructions 'V8.2' issued January 2019. Cure for 10 minutes@25°C. For use with water up to 85°C. This material is only approved for the curing conditions that appear on the approval. If the cure conditions are varied from those specified on the approval then the material is not covered by the scope of the approval.
'4300051 PVC Inner Hose (black coloured) & 4300052 PVC Inner Hose (white coloured). Single layered, extruded PVC hoses. For use with water up to 65°C.
`Silicone Valve Grease - 0250/0077`. Unpigmented (colourless), translucent silicone grease. For use with water up to 85°C.
'Mapex AN4920SN FWB50'. Black coloured, injection moulded polyamide (with glass fibre) material. For use with water up to 85°C.
'Reno 100'. Black coloured (with blue external stripes), extruded polyethylene pipe. For use with water up to 23°C.
'Reno 100+'. Dual layered, extruded polyethylene pipe comprising of a black coloured inner and blue coloured outer layer. For use with water up to 23°C.
'Dura.Blu PE 100 Ring (Blue)'. Blue coloured, extruded, ring-shaped polyethylene fitting. For use with water up to 65°C.
'Dura.Blu PE100 Fabricated Fitting'. Blue coloured polyethylene fitting manufactured by extrusion and butt fusion/weding jointing. For use with water up to 65°C.
'Wevonat 1000 & Wevopur 2082'. Factory applied, two-component polyurethane potting compound which is cream in colour once mixed. Mix and apply 'Wevonat 1000 & Wevopur 2082' as per Wevo Technical Datasheet 'pur2082_nat1000_engl version 12/18'. Cure for 8 hours@80°C. For use with water up to 23°C. This material is only approved for the curing conditions that appear on the approval. If the cure conditions are varied from those specified on the approval then the material is not covered by the scope of the approval.
'PROV200'. Grey coloured, two-component chemical anchor resin. Mix in a 10:1 volume ratio. Apply as per manufacturer's instructions 'Rev 02/2020'. Cure for 7 days@7°C. For use with water up to 23°C. For use only as a resin anchor having been tested at a reduced surface area to volume ratio of 1,000mm² per 1 litre of water. This material is only approved for the mixing and curing conditions that appear on the approval. If the mix and cure conditions are varied from those specified on the approval then the material is not covered by the scope of the approval.
'JHSX-02'. Black coloured, compression moulded EPDM rubber material. Shore hardness 50. Tested in-radius size 1.05mm. For use with water up to 85°C.
'SIL60 RED 'O' rings and seals'. Red coloured, injection moulded silicone rubber 'O' rings and seals. Shore hardness 60. The 'O' rings have a tested in-radius size of 1.77mm. The seals have a tested in-radius size of 0.90mm. For use with water up to 85°C.
'S71U 'O' rings'. Off white coloured (translucent), compression moulded VMQ 'O' rings. Shore hardness 70. Tested in-radius size between 0.89mm & 2.85mm. For use with water up to 85°C.
'Griffon WDF-05'. Site applied, blue coloured solvent cement. Apply as per manufacturer's instructions '6311380 20200708'. Cure for 30 minutes@12°C. For use with water up to 23°C. This material is only approved for the curing conditions that appear on the approval. If the cure conditions are varied from those specified on the approval then the material is not covered by the scope of the approval.
Bidet seat assembly which discharges via a sensor actuated solenoid valve and utilises a ‘Type AD’ air gap arrangement (suitable for backflow prevention against Fluid Category 5). The inlet incorporates a strainer and flow regulator (not verified by the test facility) and is pumped from an internal water storage cistern via a heating unit to various outlet nozzle arrangements. Maximum working pressure 10 bar. Cold water supply only.
Bidet seat assembly which discharges via a sensor actuated solenoid valve and utilises a ‘Type AD’ air gap arrangement (suitable for backflow prevention against Fluid Category 5). The inlet incorporates a strainer and flow regulator (not verified by the test facility) and is pumped from an internal water storage cistern via a heating unit to various outlet nozzle arrangements. Maximum working pressure 10 bar. Cold water supply only.
Bidet seat assembly which discharges via a sensor actuated solenoid valve and utilises a type `AB` airgap (verified by test - suitable for backflow protection against fluid category 5). The inlet incorporates a strainer and flow regulator and is pumped from an internal water storage cistern via a heating unit to various outlet nozzle arrangements. Maximum working pressure 10.0 bar. Cold water supply only.
Bidet seat assembly which discharges via a sensor actuated solenoid valve and utilises a type `AB` airgap (verified by test - suitable for backflow protection against fluid category 5). . The inlet incorporates a strainer and flow regulator (not verified by the test facility) and is pumped form an internal water storage cistern via a heating unit to various outlet nozzle arrangements. Maximum working pressure 10.0 bar. Cold water supply only.
Single hole, single outlet, fixed electronically controlled tap assembly with brass bodies (various finishes), incorporating a solenoid valve controlling the flow which is activated via an infrared sensor. The spout outlet incorporates a plastic aerator. The product is supplied with a stainless steel braided PEX lined flexible hose assembly and a metal backnut. Maximum working pressure 8.0 bar. Maximum operating temperature 60°C.
Bottom entry BS1212-4 (2016) delayed action type float operated valve for WC flushing cisterns. Maximum working pressure 10.0 bar. Cold water use only.
Side entry BS1212-4 (2016) delayed action type float operated valve for WC flushing cisterns. Maximum working pressure 10.0 bar. Cold water use only.
Vertical and side entry BS1212-4 (2016) compact type float operated inlet valve for WC flushing cisterns with a plastic body and adjustable float, EPDM ‘O’-rings and a plastic flow regulator at the inlet. Maximum working pressure 10.0 bar. Cold water use only.
Bottom entry BS1212-4 (2016) compact type float operated inlet valve for WC flushing cisterns with a plastic body and adjustable float, EPDM ‘O’-rings and a plastic flow regulator at the inlet. Maximum working pressure 10.0 bar. Cold water use only.
Five-hole, single outlet (fixed) combination tap assembly with brass bodies (various finishes), incorporating a quarter turn ceramic disc headworks to control the flow and a manual diverter to shower outlet both with single lever operating members. The spout outlet incorporates a plastic flow straightener. The product is supplied with a shower hose, shower handset and metal backnuts. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.
Spring loaded, resilient trim, in-line check valve cartridges, with plastic guides and jumper and NBR rubber seals within a plastic housing. For insertion in pipes and fittings with specifically sized bores. Maximum working pressure 16.0 bar. Maximum operating temperature 85°C.
Spring loaded in-line check valve cartridge with plastic guides, plunger & housing and NBR rubber seals. For insertion in pipes and fittings with specifically sized bores. Maximum working pressure 16.0 bar. Maximum operating temperature 85°C.
Range of ceramic disc headworks with brass bodies and EPDM rubber ‘O’-rings for insertion into specifically dimensioned tap assemblies. Maximum working pressure 10.0 bar. Maximum operating temperature 85°C.
Range of thermostatic cartridges with plastic bodies, stainless steel strainers and EPDM ‘O’-rings. For insertion into specifically dimensioned tap bodies. Maximum working pressure 10.0 bar. Maximum operating temperature 80°C
Single hole, single outlet (fixed) combination tap assembly (chromium plated brass), incorporating a ceramic cartridge headwork with a single lever operating member. The spout outlet incorporates a plastic aerator. Product is supplied with a click waste. Maximum operating pressure 5.0 bar. Maximum operating temperature 60°C.
Single hole, single outlet (fixed) combination tap assembly (chromium plated brass), incorporating non-rising spindle headworks with dome type operating members. The spout outlet incorporates a plastic flow straightener. Product is supplied with a click waste. Maximum operating pressure 5.0 bar. Maximum operating temperature 60°C.
Single hole, single outlet (fixed) combination tap assembly (chromium plated brass), incorporating a ceramic cartridge headwork with a single lever operating member. The spout outlet incorporates a flow straightener. Product is supplied with a click type waste. Maximum operating pressure 5.0 bar. Maximum operating temperature 65°C.
Single hole, single outlet (fixed) combination tap assembly (chromium plated brass), incorporating a ceramic cartridge headwork with a single lever operating member. The spout outlet incorporates a plastic flow straightener. The product is supplied with a click type waste. Maximum working pressure 10 bar. Maximum operating temperature 70°C.
Range of single hole, single outlet (fixed) brass bodied combination tap assemblies (various finishes, see model). Incorporating ceramic cartridge headwork and single lever operating members. The spout outlet incorporates a plastic aerator. Models A42568VUK, A4256834VUK, A4256826VUK & A4256836VUK are supplied with a pop-up waste. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.
Deck mounted, single hole, single outlet (fixed) combination tap assembly (chromium plated brass) incorporating a ceramic cartridge headwork with a single lever operating member. The spout outlet incorporates a plastic flow straightener. Maximum working pressure 5.0 bar. Maximum operating temperature 60ºC.
Range of single hole, single outlet, fixed combination tap assemblies (chromium plated brass), incorporating a ceramic cartridge headwork with a single lever operating members. The spout outlet incorporates a plastic aerator and the product is supplied with either a lever or click type pop up waste (see models). Maximum working pressure 5.0 bar. Maximum operating temperature 60.0°C
Single hole, single outlet fixed combination tap assembly (chromium plated brass), incorporating quarter turn ceramic disc headworks with cross top operating members. Product is supplied with a pop-up waste. Maximum operating pressure 5.0 bar. Maximum operating temperature 60°C
Range of single hole, single outlet (fixed) combination tap assemblies (various finishes, see model). Incorporating ceramic cartridge headworks, and single lever operating members. The inlets incorporate flow strainer and the spout outlet incorporates a plastic flow straightener. Can be supplied with our without a pop up waste. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.
Range of deck mounted, electronically operated combination tap assemblies (chromium plated brass) incorporating a solenoid valve controlling the flow which is actuated via in infrared sensor. The spout outlet incorporate a plastic aerator. Maximum working pressure 6.0 bar. Maximum operating temperature 65°C.
Floor mounted single hole, single outlet (fixed) combination tap assembly (chromium plated brass) incorporating a ceramic cartridge headwork with a single lever operating member and a self-cancelling diverter to shower outlet. The shower outlet and hose incorporates an approved check valve cartridge however, the complete product has not been fully tested to demonstrate it provides backflow protection. The spout outlet incorporates a plastic aerator. The product is supplied with a shower hose and handset. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.
Single hole, single outlet (swivel) combination tap assembly (chromium plated brass), incorporating ceramic disc headworks with single lever operating members. The spout outlet incorporates a plastic flow straightener. Maximum working pressure 5.0 bar. Maximum operating temperature 65°C.
Single hole, single outlet (swivel) combination tap assembly (chromium plated brass), incorporating non-rising spindle headworks. The spout outlet incorporates a plastic flow straightener. Maximum working pressure 7.0 bar. Maximum operating temperature 60°C.
Single hole, single outlet (swivel) combination tap assembly (chromium plated brass), Incorporating quarter turn ceramic disc headworks and single lever operating members. The spout outlet incorporates a plastic aerator. The hot inlet incorporates an adaptor which is fitted with a single check valve cartridge however, the complete assembly has not been tested to demonstrate it provides adequate backflow protection. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.
Range of single hole, single outlet (swivel) combination tap assemblies with brass bodies (various finishes), incorporating a ceramic cartridge headwork or quarter turn ceramic disc headworks with single lever or dome type operating. The spout outlets incorporate a plastic flow straightener or aerator. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.
Single hole, single outlet (swivel) combination tap assembly with brass body (chromium plated), incorporating a ceramic cartridge headworks and single lever operating member. The outlet incorporates a plastic aerator. Maximum working pressure 5.0 bar. Maximum operating temperature 55°C.
Range of single hole, single outlet (swivel) combination tap assemblies (various finishes), incorporating a quarter turn ceramic cartridge headwork and single lever operating members. The spout outlet incorporates a plastic aerator. Maximum working pressure 8.0 bar. Maximum operating temperature 65°C.
Range of single hole, single outlet (swivel) combination tap assemblies (Chromium plated or brushed nickel finish), incorporating quarter turn ceramic disk headworks with single lever operating members. The spout outlet incorporates a plastic flow straightener. Supplied with approved single check valves, verified by test (suitable for backflow protection against Fluid Category 2) with integral servicing valve for both inlets. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C
Range of single hole, single outlet (swivel) combination tap assemblies (stainless steel). Incorporating ceramic cartridge headworks and single lever operating members. The spout outlet incorporates a plastic aerator. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C
Range of single hole, single outlet (swivel) combination tap assemblies (chromium plated brass). Incorporating quarter turn ceramic disc headworks and single lever operating members. The spout outlets incorporate a plastic flow straightener . Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.
Range of single hole, single outlet (swivel) combination tap assemblies (chromium plated brass). Incorporating a ceramic cartridge or quarter turn ceramic disc headworks (model CUC-1060-C/P) and single lever operating members. The spout outlet incorporates a plastic aerator, models ORI-150S-C/P & CUC-1060-C/P the plastic aerator is within a brass housing with a metal mesh. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.
Range of single hole, single outlet (swivel) combination tap assemblies (chromium plated brass). Incorporating ceramic cartridge headworks and single lever operating members. The spout outlets incorporate a plastic aerator. Maximum working pressure 5.5 bar. Maximum operating temperature 60°C.
Single hole, double outlet (fixed) combination tap assembly (chromium plated brass), incorporating non-rising spindle headworks with dome type operating members. Product is supplied with a pop-up waste. Maximum operating pressure 5.0 bar. Maximum operating temperature 65°C.
Two hole, single outlet (fixed) combination tap assembly (chromium plated brass) incorporating a ceramic cartridge headwork with single lever operating member. The spout outlet incorporates a plastic aerator. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.
Wall mounted two hole, single outlet (swivel) combination tap assembly with DZR brass bodies (various finishes). Incorporating a ceramic cartridge headwork and single lever operating members. The spout outlet incorporates a plastic aerator. Product is supplied with a pop-up waste. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.
Two hole, single outlet fixed combination tap assembly (chromium plated brass) incorporating quarter turn ceramic disc valve headworks with single lever operating members. The spout outlet incorporate a plastic flow straightener. Product is supplied with metal back nuts. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.
Range of exposed wall mounted two-hole, single outlet (fixed) combination tap assemblies with brass bodies (various finishes), incorporating a two-way manual diverter controlling and diverting the flow between the spout outlet and an overhead shower (not supplied) and a single lever operating member. The temperature is controlled independently via a thermostatic cartridge with a single lever operating member incorporating a manual override button. The inlets incorporate a stainless steel strainer and an approved check valve cartridge, however, the complete product has not been fully tested to demonstrate it provides backflow protection. The spout outlet incorporates a plastic aerator. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.
Two hole metal single outlet (fixed) combination tap assembly (chromium plated brass) incorporating quarter turn ceramic disc headwork with single lever operating members and a self-cancelling diverter to shower outlet. The spout outlet incorporates a plastic flow straightener and the product is supplied with metal backnuts, hose and handset. Maximum working pressure 10.0 bar. Maximum operating temperature 70°C.
Two hole, single outlet (swivel) combination tap assembly (chromium plated brass), incorporating non-rising spindle headworks with cross top operating members. The spout outlet incorporates a plastic flow straightner. The product is supplied with metal backnuts. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.
Range of two hole, singleoutlet (swivel) combination tap assemblies (chromium plated brass). Incorporating non rising spindle headworks with various operating members. The spout outlets incorporate a plastic flow straightener. Products are supplied with plastic backnuts, model DCM SPEC105 is supplied with metal backnuts Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.
Two hole, double outlet (swivel) combination tap assembly (chromium plated brass) incorporating non-rising spindle headworks with dome type operating members. Product is supplied with metal back nuts. Maximum working pressure 8.0 bar. Maximum operating temperature 60°C.
ALT Series of wall mounted anti-ligature outlets with a touch operated solenoid valve incorporating a flow regulator which controls the flow. The outlets arrangement can be either a single inlet/outlet (ALT-81) or two independent inlets and outlets (ALT-80) both controlled via a solenoid valve. To be installed within a suitable basin (not supplied as part fo the this approval) Internal connecting pipework can be either threaded or push fit depending on model variant. Can be fitted with either an approved aerator or flow straightener. Maximum working pressure 10 bar. Maximum operating temperature 60°C
WHB & ALS series of wall mounted anti-ligature wash hand basins with outlets. Incorporating a basin with a piezo activated button or infrared activation which controls the flow via a solenoid valve to either an independant single or double inlet made from chromium plated brass and incorporating a flow straightener or aerator. Internal connecting pipework can be either threaded or push fit depending on model variant. Maximum working pressure 10 bar. Maximum operating temperature 60°C
Bath spout with a brass body (chromium plated). The spout outlet incorporates a plastic aerator. Maximum operating temperature 60°C.
Range of expansion vessels incorporating butyl rubber diaphragms. Maximum working pressure, see model. Cold water use only.
Talbot range of self tapping ferrule straps with plastic bodies and a nitrile rubber seal. The product incorporates either a ¾” BSP (M) connection or a 25mm or 32mm push fit connection on the outlet from the cutting arm. For below ground use only. Maximum working pressure 16.0 bar. Cold water use only.
Range of stainless-steel press fittings with EPDM ‘O’-rings and EPDM washer (Live joint with BSP female thread models only) for use with stainless-steel pipe. Joints are achieved using a press fitting tool. Maximum working pressure 16.0 Bar. Maximum operating temperature 85°C.
Range of copper solder ring fittings for use with EN 1057 copper tube. For above ground use only. Maximum working pressure 16.0 bar. Maximum operating temperature 85°C.
‘EPH_WSP19’ Range of brass bodied fittings for use with copper pipe, some fittings are to be soldered with copper pipe (see models). Maximum working pressure 10.0 Bar. Maximum operating temperature 85°C.
Range of rigid ductile iron couplings (copper colored alkyd enamel) (Style 606-EN), Vic-flange adapter’s (Style 641-EN) and grooved copper fittings (No. 610, 611, 620, 625, 650 & 660 –EN) for use with grooved copper tubing (manufactured to EN 1057 R250). Above ground use only. Maximum working pressure 10.0 bar. Maximum operating temperature 65°C.
Fluidfit range of hose barb fittings/stem fittings with push fit connections. Also with EPDM ‘O’-rings. 12 & 15mm models are for use with LLDPE pipe, 22mm models are for use with PEX pipe. Cold water use only Maximum working pressure 10.0 Bar
‘EPH_WSP19’ Range of brass bodied fittings for use with copper pipe, some fittings are to be soldered with copper pipe (see models). Maximum working pressure 10.0 Bar. Maximum operating temperature 85°C.
Range of copper end feed fittings for use with copper tube. For above and below ground use. Maximum working pressure 16.0 bar. Maximum operating temperature 85°C
Range of dual flush WC syphons incorporating a polypropylene body, stainless steel C link and a LDPE sealing washer. The valve is to be operated via a handle lever. Cold water use only.
Range of urinal autosyphons with a plastic body & supplied with plastic backnuts.
Range of infra-red controlled urinal flush valves and link box, incorporating a stainless-steel strainer, flow straightener. The unit comprises a normally closed solenoid valve and an infra-red sensor. Maximum working pressure 10.0 bar. Maximum operating temperature 85°C.
Range of modular combined heating interface units providing a combination of either hot water, heating or cooling via a plate heat exchanger depending on model options. Heating and cooling circuits incorporate a safety relief valve (set at 3 bar) and expansion vessel and inlet connection can be either top or bottom entry configuration. Maximum working pressure 16 bar (primary, CWS and HWS) 2.5 bar on heating circuit. Maximum operating temperature 85°C.
Range of stainless steel plate heat exchangers. The product incorporates a stub pipe with a ½” BSP (F) end connection on the secondary flow (outlet) which can accommodate a control sensor and strap on limit thermostat, (neither of which are supplied or considered part of the approval listing). Maximum working pressure 10.0 bar. Maximum working temperature 85°C.
‘Nova-Flo’ inline flow control device with a plastic body and EPDM ‘O’-rings. The product is intended to restrict the flow of water to a bath or basin if water level reaches the overflow. Float located within the overflow pathway activate flaps on each inlet to restrict the flow prior to the taps being closed. Maximum Working pressure 10.0 bar. Maximum operating temperature 60°C.
NIVUS range of flow sensors with stainless steel bodies. Sensors incorporate EPDM seals and a PTFE olive. Maximum working pressure 16.0 bar. Cold water use only.
Range of shower hoses and riser rail with chromium plated brass bodies, incorporating EPDM ‘O’-rings. Maximum operating temperature 85°C.
Shower hose and handset with sliding rail and inlet kit. The inlet incorporates an approved check valve cartridge, however, the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum operating temperature 60°C.
Range of plastic manifold systems designed to accept interchanagble sensors (not supplied). Maximum working pressure 6.0 bar. Cold water use only.
Immersion temperature sensors with DZR bodies and an EPDM ‘O’-ring (STDW14 model only). Maximum working pressure 15.0 bar. Maximum operating temperature 100°C.
Range of cold water supply booster sets, incorporating a stainless steel manifold system and between 1 and 4 pumps depending on model. The booster sets also incorporate spherical valves, non-return valves, pressure switches/sensors and expansion vessels. Maximum working pressure 10.0 bar or 16.0 bar, dictated by the pump model(s) fitted. Cold water use only.
Range of shower booster pumps (either single or double) with acetal bodies and impellers and EPDM seals and NBR `O`-rings. Supplied with stainless-steel braided EPDM lined flexible hoses incorporating isolation valves Maximum working pressure 3.0 bar. Maximum operating temperature 65°C.
Self-priming electric booster pump with plastic body incorporating plastic impellers with variable speed settings, and a non-return return valve (not suitable for backflow protection). Maximum working pressure 8.0 bar. Cold water use only.
Range of over head shower outlets with stainless steel bodies (various finishes). Inlets incorporate silicone washer with stainless-steel strainer. Maximum working pressure 5.0 bar. Maximum operating temperature 85°C.
Range of overhead wall mounted shower outlets with brass bodies (various finishes), incorporating a plastic aerator and stainless-steel strainers on two of the three inlets to the main body. The 35 283 xxx models also incorporate plastic flow regulators on all three of the inlets to the main body. Maximum operating temperature 60°C.
Range of shower handsets (chromium plated ABS) with stainless steel strainers and a built-in approved single check valve cartridge, however, the complete product has not been fully tested to demonstrate it provides backflow protection. Model 28016979-00 has an adjustable flow pattern which switches between 3 patterns. Maximum operating temperature 60°C
Range of wall mounted shower outlets in various finishes. Maximum operating temperature 80°C.
Shower kit comprising of shower handset (chrome plated brass body), shower hose, 90° wall elbow, stainless-steel braided supply hose & faceplate with single lever operating members. The inlet to the shower handset incorporates an approved single check valve cartridge, however, the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum operating temperature 60°C.
Shower kit consisting of a shower handset (chrome plated plastic), riser rail and PVC lined multi-layered shower hose with brass connections, EPDM 'O'-rings and washers. Maximum operating temperature 60°C.
Range of in-line `Y`-patterned strainers with bronze bodies incorporating stainless steel mesh strainers and PTFE washers. Maximum working pressure 20.0 bar. Maximum operating temperature 85°C.
Drain off valve with a DZR brass body. Maximum working pressure 15.0 bar. Maximum operating temperature 85°C.
Range of pillar taps (chromium plated brass) incorporating non-rising spindle headwork with cross top operating members. The spout outlet incorporates a plastic flow straightener. The product is supplied with metal backnuts. Maximum working pressure 7.0 bar. Maximum operating temperature 65°C.
Range of pillar taps (chromium plated brass) with quarter turn ceramic disc headworks and cross top operating members. The product is supplied with metal backnuts. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.
Range of pillar taps with brass bodies (chromium plated or gold effect finish), incorporating quarter turn ceramic disc headworks with single lever operating members. The spout outlets incorporates a plastic flow straightener and the product is supplied with plastic backnuts. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.
Range of pillar taps (chromium plated brass) incorporating non-rising spindle headwork with cross top operating members. The spout outlet incorporates a plastic flow straightener. The product is supplied with metal backnuts. Maximum working pressure 7.0 bar. Maximum operating temperature 65°C.
Range of pillar taps (chromium plated brass) incorporating ¼ turn ceramic disc headworks with single lever operating members. The spout outlet incorporates a plastic aerator. The product is supplied with metal backnuts. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.
Wall mounted self-closing basin tap (chromium plated brass), incorporating a non-concussive headwork with a dome type operating member. The spout outlet incorporates a plastic flow straightener. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.
Range of braided (stainless steel or stainless steel braided plus black nylon wire or nylon) PEX lined flexible hose assemblies with various end connections and lengths (see model section). Connections 35, 36, 37, 38, 39, 40, 41 and 42 noted within the model section are for use with copper tube manufactured to BS2871 or PPR pipe manufactured to BS 15874. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.
Fabdec ‘Excelsior’ ranges of direct, indirect, solar direct and solar indirect stainless steel insulated unvented hot water storage cylinders with internal expansion. The DHW circuit consists of a temperature and pressure relief valve set at 7.0 bar 95°C, an inlet manifold consisting of an in-line pressure reducing valve adjustable between 2.7 & 3.3 bar (but factory set @ 3.0 bar), an approved check valve cartridge, verified by test (suitable for backflow protection against Fluid Category 2), a pre-set expansion relief valve set at 6.0 bar and a strainer. The product is supplied with a tundish. Maximum supply pressure to pressure reducing valve is 10.0 bar. Maximum working pressure Primary circuit 6.0 bar. Maximum working pressure Secondary circuit 5.5 bar. Maximum operating temperature 85˚C.
Range of air venting valves with a gunmetal body PTFE seats and fluoroelastomer ‘O’-rings. Maximum working pressure 13.5 bar. Maximum operating temperature 95°C.
Range of brass bodied automatic air venting valves incorporating a plasitc float. The 501.512 AAV and 501.515 AAV models are supplied with an isolation valve, comprising of a brass body with a plastic plunger, spring, NBR ‘O’-ring and PTFE seal. The plunger is pushed open when the air venting valve is attached and the spring closes it when the air venting valve is removed. Maximum working pressure 10.0 bar. Maximum operating temperature 110°C.
Range of wall mounted concealed manual blending valves with a DZR brass body incorporating a ceramic cartridge headwork with a single lever operating member, fitting is available with trim set (available in various finishes). Maximum working pressure 10.0 bar. Maximum working temperature 70°C.
Range of exposed or concealed non concussive shower valves, incorporating a brass body with chrome plating on the exposed version or a chrome plated cover pate on the concealed option. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.
Range of shower kits consisting of a wall mounted thermostatic shower mixer with brass bodies (various finishes) incorporating a ceramic disc headworks controlling the flow, temperature is controlled via a thermostatic cartridge and single lever operating members. Supplied with a shower hose, shower handset, riser rail and soap dish. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.
Range of concealed thermostatic mixing valves. Flow is controlled via a quarter turn ceramic disc headworks to two shower outlets.Temperature is controlled independently via a thermostactic mixing valve with various operating members. Inlets incorporate stainless steel strainers & single check valve cartridges however, the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum working pressure 5.0 bar. Maximum operating temperature 65°C.
Wall mounted thermostatic blending valves (chromium plated brass) incorporating a quarter turn ceramic disc headwork controlling the flow with a single lever operating member. The temperature is controlled independently via a thermostatic cartridge with a single lever operating member. Both inlets incorporate single check valve cartridges, verified by test (suitable for backflow protection against Fluid Category 2) and a stainless-steel filter. Maximum working pressure 5.0 bar. Maximum operating temperature 85°C.
Range of wall mounted, thermostatic shower valves. Models TF1S, ARC73 NKL, HOX.024CP, HOX.024MB, GUI.023. HOX.006, HOX.024BB, GUI.024 HOX.006, RIV2 CHR & RIV GOLD are concealed and have a single outlet. Models GUI.023 HOX.005, TF2S, ARC64 NKL, TF3S, HOX.023CP, HOX.023MB, HOX.023BB, GUI.024 HOX.005, RIV3 CHR & RIV3 GOLD are concealed and have a double outlet. Model AF1S is exposed and has a single outlet. Model AF3S & ARC74 NKL are exposed and have a double outlet. Models TF2S, TF3S and AF3S are supplied with a shower hose handset. The flow is controlled by a quarter turn ceramic disc or two-way manual diverter with cross top or single lever operating members. The temperature is controlled independently via a thermostatic cartridge with cross top or single lever operating members The inlets incorporate approved check valve cartridge, however, the complete product has not been fully tested to demonstrate it provides backflow protection, models beginning with ‘TF’ incorporate a stainless-steel strainer. Maximum working pressure 10.0 Bar. Maximum operating temperature 60°C.
Range of wall mounted, thermostatic shower valves with chromium plated brass body. Flow is controlled by a quarter turn ceramic disc headwork with single lever operating members. Temperature is controlled by a thermostatic cartridge with a dome type operating member which incorporates a manual override button. The inlets incorporate a stainless steel strainer and an approved check valve cartridge however, the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum working pressure 10.0 bar. Maximum operating temperature 70°C
Range of thermostatic blending valves with brass bodies (various finishes, see models), incorporating a thermostatic cartridge that controls the temperature. Supplied with either lever or cross top operating members depending on model. The inlets incorporate approved check valve cartridges, however, the complete product has not been fully tested to demonstrate it provides backflow protection Maximum working pressure 5.0 bar. Maximum operating temperature 85ºC.
Range of wall mounted concealed shower mixer (brass body) incorporating a 3-way manual diverter valve controlling and diverting the flow with a dome type or single lever operating member (see model). The temperature is controlled independently via a thermostatic cartridge with a dome type or single lever operating member (see model) incorporating a manual override button. Both inlets and the shower outlet connection incorporate approved check valve cartridges, however, the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.
Range of concealed thermostatic blending valve (brass body), incorporating a half turn ceramic disc headwork controlling the flow with a dome type (Rakama) or single lever (Rakita) operating member. Temperature is controlled independently via a thermostatic cartridge with a dome type (Rakama) or single lever (Rakita) operating member incorporating a manual override button. The inlets incorporate approved check valve cartridges. However, the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C
Range of wall mounted, concealed, thermostatic shower blending valves with brass bodies (various finishes, operating members and trim kits - SD127 prefix models are available in the following finishes - Chrome (CR), Brushed Black (BBR), Brushed Black, Matt Black (MB). All other models are available in Chrome (CR) finish). The 2500 model variants incorporate a ¼ turn ceramic disc headwork controlling the flow to a single outlet. The 2501 model variants incorporate a 2 way ceramic disc diverter (2 on, 1 off) controlling the flow between two outlets. The 2503 model variants incorporate two ¼ turn ceramic disc headworks controlling the flow to two separate outlets. The 2504 model variants incorporate a 2 way ceramic disc diverter (2 on, 1 off) controlling the flow between two outlets and an additional a ¼ turn ceramic disc headwork controlling the flow to a separate single outlet. In all models the temperature is controlled independently via a thermostatic cartridge incorporating a manual override button. Both inlets incorporate a stainless steel strainer and an approved check valve cartridge, however, the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.
Range of concealed 2 and 3 outlet thermostatic mixers with brass bodies and thermostatic cartridge controlling the temperature. The inlets incorporate a single check valve cartridge, however, the complete product has not been fully tested to demonstrate it provides backflow prevention. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.
Range of T-type thermostatic mixing valves with DZR brushed chrome brass bodies and a thermostatic cartridge controlling the temperature. Models TM200VP-3/4ZC and TM200VP-3/4ZD incorporate isolation valves and stainless steel strainers on the inlets. All models incorporate check valve cartridges, verified by test (suitable for backflow protection against Fluid Category 2). Maximum working pressure 10.0 bar. Maximum operating temperature 60ºC.
Range of wall mounted thermostatic shower valves with brass bodies (various trims & finishes), supplied with shower hose and handset. The flow is controlled via a quarter turn ceramic disc headwork with dome type operating member. The temperature is controlled independently via a thermostatic cartridge with a dome type operating member. The inlets incorporate an approved check valve cartridge however, the complete product has not been fully tested to demonstrate it provides backflow protection Maximum working pressure 5.0 bar. Maximum operating temperature 70°C.
Range of wall mounted, concealed thermostatic blending valves incorporating brass bodies and various head works. GR-AZ-50 model x1 ¼ turn ceramic disc headwork controlling the flow. GR-AZ-51 model x1 manual diverter controlling the flow. GR-AZ-52 model x2 ¼ turn ceramic disc headworks controlling the flow. GR-AZ-53 model x1 ¼ turn ceramic disc headwork controlling the flow and x1 manual diverter only. All models have an independent thermostatic cartridge controlling the temperature with a manual override button. Both inlets incorporate a stainless steel strainer and an approved check valve cartridge, however, the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum working pressure 5.0 bar. Maximum operating temperature 85°C.
2-way ceramic disc diverter with a plastic body. For insertion into specifically dimensioned tap bodies. Maximum working pressure 3.0 bar. Maximum operating temperature 85°C.
Range of, two way and three way diverter valves incorporating brass bodies The valves are fitted with ceramic disc diverters or headwork, and can be supplied with or without a shutoff valve. Maximum working pressure 20.0 bar. Maximum operating temperature 80°C.
Range of float operated valves incorporating stainless steel bodies and float arms. Maximum working pressure 10.0 bar. Cold water use only.
In-line manually adjustable pressure reducing valves with a DZR brass body, piston and stem. Product is supplied with guages Maximum inlet pressure 20.0 bar. Outlet pressure range 1.0 to 6.0 bar. Maximum operating temperature 100°C.
Pressure relief valve (pre-set at 3.0 bar) with a brass body. The valve incorporates a manually operated easing gear. Maximum operating temperature 110°C.
Range of pressure relief valves with gunmetal bodies, silicon rubber diaphragm, chrome vanadium steel spring and a lever operated easing gear. Pre-set relief pressures: DN15-25 - 1.0 bar to 12.5 bar. DN32-65 - 0.4 bar to 12.5 bar. Maximum operating temperature 95˚C
Range of pre-set (at 3.0 bar) pressure relief valves incorporating DZR brass bodies and an EPDM diaphragm. The valve is fitted with hand operated rotating easing gear. Maximum operating temperature 85°C.
Range of normally closed solenoid valves with brass bodies Maximum operating pressure 10.0 bar. Maximum operating temperature 85°C.
Range of normally closed (monostable) and pulse controlled/latching (bistable) solenoid valves with plastic bodies, integral stainless steel strainer, From September 2023 the 50.005.101 model can also be supplied with an integral plastic strainer. EPDM diaphragm, EPDM ‘O’-rings and seals. To be installed in specifically dimensioned bodies. The 50.005.101 model can be supplied with or without a brass adaptor. Maximum working pressure 10.0 bar. Maximum operating temperature 70°C.
Range of lever operated servicing valves for use with BS EN 1057 R250 half hard copper tube, incorporating brushed chromium plated DZR brass bodies and ball, and PTFE seats. Maximum working pressure 16.0 bar. Maximum operating temperature 85°C.
Range of in-line isolation valves with a nickel plated brass (11-1046 (1046) range) or DZR brass body (all other models), chromium plated DZR brass ball (1601 (¼ ” to 2”), 2045 (¼” to 2”) & 1046 ranges), SS304 ball (1601 (¾” to 2”) & 2045 (¼” to 2”) ranges) or chromium plated brass ball, and PTFE seats. The products are supplied with either a single lever (1601, 2045 & 1046 range), single lever with extension stem kit, (1601 & 2045 range), single lever with lockable handle (1601 & 2045 range), butterfly operating members (1601 & 2045 range), T-handle, short black lever (1601 & 2045 range) or screwdriver operated (1046 range). The 11-1015 (2045) range and 11-1046(1046) range is for use with copper pipe manufactured to EN1057. Maximum working pressure 40.0 bar (1601 range), 25.0 bar (2045 & 1046 range). Maximum operating temperature 85°C.
Range of spherical valves incorporating gunmetal bodies and EPDM ‘O’-rings. Valves can be either handle operated or actuator operated 24v or 230v and with or without return spring (see model). Maximum working pressure 16.0 bar. Maximum operating temperature 85°C.
Range of spherical ball valves with single lever or T-handle operating members, brass bodies (nickel plated) and chromium plated brass ball and PTFE washers. Maximum working pressure CP90 models = 40.0 bar. CP89 models = 25.0 bar. Maximum operating temperature 85.0°C
Spherical valves incorporating bronze bodies with lever operating members, chromium plated brass ball and PTFE seat. Maximum working pressure 25.0 bar, Maximum operating temperature 85°C.
Spherical valves incorporating bronze bodies with lever operating members, chromium plated brass ball and PTFE seat. Maximum working pressure 25.0 bar, Maximum operating temperature 85°C.
Spherical valves incorporating bronze bodies with lever operating members, chromium plated brass ball and PTFE seat. Maximum working pressure 25.0 bar, Maximum operating temperature 85°C.
Spherical valves incorporating bronze bodies with lever operating members, chromium plated brass ball and PTFE seat. Maximum working pressure 25.0 bar, Maximum operating temperature 85°C.
Range of plastic bodied inline, tee and angled spherical valves with EPDM ‘O’-rings and either lever or screwdriver operated (see model). For use with copper and PE-x pipe (manufactured to BS7291-3). Maximum working pressure 10.0 bar. Maximum operating temperature 65°C.
Range of gate valves incorporating either rising or non-rising spindle headworks and PTFE gaskets. The products are available as follows: Bronze body, bronze wedge and handwheel (132 prefix models). Bronze body, bronze wedge and handwheel (133 prefix models) or lockshield operating member (136 prefix models). Maximum working pressure 20.0 bar. Maximum operating temperature 85°C.
Range of gate valves with bronze bodies with metal seats. The valves operate via a non-rising spindle headworks that incorporate a wheel type operating member or lock shield type (see models) Maximum working pressure 20.0 bar. Maximum operating temperature 85°C
Range of gate valves with bronze bodies, bronze wedge and PTFE gaskets. The valves operate via a hand wheel. Maximum working pressure 20.0 bar. Maximum operating temperature 85°C.
Range of gate valves FIG. 100 and FIG. 100LK with bronze bodies and bronze wedges. The valves operate via non-rising spindle head work with hand wheel or lock shield operating members. Maximum working pressure 20.0 bar. Maximum operating temperature 100°C
Range of 2, 3 or 4 way manifolds incorporating brass bodies (nickel plated), stop valves and EPDM seats. Maximum working pressure 10.0 bar. Maximum operating temperature 85°C.
Range of inline screw down stop valves with plastic bodies, non-rising spindle headworks and dome type operating members for use with PE-x (manufactured to BS7291-3) and copper pipe. Maximum working pressure/temperature: 10.0 bar @ 20°C and 10.0 bar @ 65°C.
Cold water inlet control group with a DZR brass body consisting of a pressure reducing valve, (adjustable between 2.7 and 3.3 bar, but factory set at 3.0 bar), a stainless steel strainer and a plastic bodied pressure relief valve (pre-set at 8.0 bar). The product incorporates a single check valve cartridge, verified by test (suitable for backflow protection against Fluid Category 2). The pressure relief valve is fitted with a rotary type easing gear. Maximum supply pressure 10.0 bar. Maximum operating temperature 85°C.
Range of bedpan macerators. The flow is controlled by solenoid valve and discharged via a type `AB` airgap (verified by test - suitable for backflow protection against fluid category 5). Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.
Commercial clothes washing machine having a flexible inlet hose and solenoid valve with filter at the inlet supplying a Maximum working pressure 10.0 bar. Maximum operating temperature 85°C.
Commercial clothes washing machine having a flexible inlet hose and solenoid valve with filter at the inlet supplying a type `AB` airgap (verified by test - suitable for backflow protection against fluid category 5). Maximum working pressure 10.0 bar. Maximum operating temperature 85°C.
Range of commercial dish washing machines. Flow is controlled by a solenoid valve and discharged via a type `AB` airgap (verified by test - suitable for backflow protection against fluid category 5). The product is supplied with stainless steel or nylon braided EPDM inlet hose. Maximum working pressure 4.0 bar. Cold water use only.
Range of ultraviolet disinfection units incorporating isolation valves and draw off tapes. Maximum working pressure 16.0 bar. Maximum operating temperature 50ºC.
Range of ultraviolet disinfection units with stainless steel bodies, quartz sleeves and silicone seals. Maximum working pressure 6.8 bar. Maximum operating temperature 40°C.
Pressure vessel with spun fibre glass casing and polyethylene liner. Maximum working pressure 10.0 bar. Maximum operating temperature 70ºC.
Range of polyethylene pressure vessels with spun fibre glass casing. Maximum working pressure 10.0 Bar. Maximum operating temperature 50°C.
'Delrin® FG500P NC010'. White coloured (opaque), injection moulded acetal material. For use with water up to 23°C.
'Delrin® FG911DP NC010'. White coloured (opaque), injection moulded acetal material. For use with water up to 23°C.
.TENAC-C 4590'. White (translucent) coloured, injection moulded acetal material. For use with water up to 85°C.
'Delrin® FG100 NC010'. White coloured (opaque), injection moulded acetal material. For use with water up to 85°C.
'ABS Grey 727 GR37 (grey coloured), ABS 727 White (white coloured), ABS 727 Grey (dark grey coloured) & ABS 727 Black (black coloured)'. ‘ABS 727 GR48 (grey coloured)’ was added to the approval on 2nd September 2022. Injection moulded ABS materials. For use with water up to 85°C.
'HF380-F'. White coloured, injection moulded ABS material. For use with water up to 85°C.
'ME782 A1203 96%'. White coloured (opaque), ceramic pressure sensor manufactured by roll pressing. For use with water up to 23°C.
'Luberpox-2K-DS-Lackfarbe IV80502 / IW 80 (Hardener) Blue Epoxy Coating'. Factory applied, blue coloured, two-component epoxy coating. Mix and apply in accordance with Technical Data Sheet rev. 37 dated 25.05.2020 . Cure for 7 days@23°C. For use with water up to 23°C. This material is only approved for the curing conditions that appear on the approval. If the cure conditions are varied from those specified on the approval then the material is not covered by the scope of the approval.
'Conpipe Portland Cement Mortar NEN-EN 197-1 CEM II / A-LL 32,5 R'. Factory applied, grey coloured cementitious mortar lining. Mix cement and sand in a 1:1.1 mass ratio. Add water to cement in a mass ratio of 0.3-0.4. Cure for 28 days@20°C. For use with water up to 60°C. This material is only approved for the mixing & curing conditions that appear on the approval. If the mix and/or cure conditions are varied from those specified on the approval then the material is not covered by the scope of the approval.
'Conpipe Portland Cement Mortar NEN-EN 197-1 CEM I 42,5 N'. Factory applied, grey coloured cementitious mortar lining. Mix cement and sand in a 1:1.1 mass ratio. Add water to cement in a mass ratio of 0.3-0.4. Cure for 28 days@20°C. For use with water up to 60°C. This material is only approved for the mixing & curing conditions that appear on the approval. If the mix and/or cure conditions are varied from those specified on the approval then the material is not covered by the scope of the approval.
'JH C01'. Factory applied, blue coloured epoxy powder coating. Apply as per manufacturer's instructions 'V7.2' issued January 2018. Cure for 15 minutes@200°C. For use with water up to 85°C.
'Interline 975'. Site applied, two-part epoxy coating comprising of Part A (white, opaque liquid) and Part B (amber, translucent liquid). Mix as per manufacturer’s instructions ref. ‘3577’ dated 31/07/2017. The coating is white coloured once mixed. Cure for 21 days@7°C. For use with water up to 23°C. This material is only approved for the curing conditions that appear on the approval. If the cure conditions are varied from those specified on the approval then the material is not covered by the scope of the approval.
'FTC GRP Panel'. Grey (opaque) coloured, compression moulded GRP panel. For use with water up to 50°C.
`YT-001`. Single layer, extruded, white coloured PEX hose. For use with water up to 85°C.
'Greasil 4000'. White coloured silicone grease. For use with water up to 85°C.
'Ultramid S3EG6 Balance Aqua Uncoloured'. Uncoloured (appears beige), injection moulded PA6/10 material. For use with water up to 85°C.
'Plustek PA7001G7BK11'. Black coloured, injection moulded polyamide material. For use with water up to 85°C.
'TYPLEX 4055'. White coloured (opaque), extruded Polybutene-1 material. For use with water up to 85°C.
'TYPLEX-1050'. Grey coloured, extruded polybutene-1 material. For use with water up to 85°C.
'ZX-100K'. White coloured (opaque) PBT case wear ring which has been stamped from sheet material. For use with water up to 23°C.
'RAMSTER PF100NT'. White coloured, injection moulded PBT material. For use with water up to 85°C.
'Fox Spigot and Electrofusion Fittings'. Black coloured, injection moulded polyethylene (PE 100-RC) spigot and electrofusion fittings. For use with water up to 65°C.
'Godavari HDPE Pipe (manufactured from Alathon L4904 & Black masterbatch)'. Black coloured (with blue external stripes), extruded HDPE pipe. For use with water up to 23°C.
'Viega Raxofix PE-Xc/Al/PE-Xc Multilayer Pipe'. Extruded PE-Xc/Al/PE-Xc multilayer pipe comprising of a black coloured PE-Xc inner layer, aluminium middle layer and grey coloured PE-Xc outer layer. For use with water up to 70°C.
'Viega Raxofix, PE-RT/Al/PE-RT Multilayer Pipe'. Extruded, multi-layered pipe comprising of a black coloured PE-RT inner layer, aluminium middle layer and grey coloured PE-RT outer layer. For use with water up to 70°C.
'Hepworth PE 80 & PE 100 Pipes'. The extruded PE 80 pipes are black coloured. The extruded PE 100 pipes are either black or blue coloured. For use with water up to 60°C.
'FRIALEN Safety Fitting' (manufactured from Eltex TUB121). Black coloured (opaque), injection moulded PE100 electrofusion fitting. For use with water up to 60°C.
'D.63 Spigot and Electrofusion Fittings'. Black coloured, injection moulded PE100 fittings. For use with water up to 23°C.
'FRIALEN Safety Fitting' (manufactured from Hostalen CRP 100 black). Black coloured (opaque), injection moulded PE100 electrofusion fitting. For use with water up to 60°C.
'RAK Universal Plastic Industries L.L.C. HDPE PE100 Black Pipe'. Black coloured, extruded HDPE pipe. For use with water up to 85°C.
'Polyatlas PE100 Pipe'. Black coloured, extruded HDPE pipe. For use with water up to 23°C.
‘LONGLITE®PSRP1000 natural (appears yellow/brown coloured), black (black coloured) & white (appears off-white coloured)’. Injection moulded PPSU materials. For use with water up to 85°C.
'NOVATHERM Pipe'. Green coloured (with external red stripes), extruded PPR pipe. For use with water up to 60°C.
'NOVATHERM Fittings'. Green coloured, injection moulded PPR fittings. For use with water up to 60°C.
'Yuhwa rp 2400 Green PPR Fitting'. Green coloured (opaque), extruded PPR fitting. For use with water up to 85°C.
'Yuhwa rp 2400 Green PPR Pipe'. Green coloured (opaque), extruded PPR pipe. For use with water up to 85°C.
'DACTAtherm PP-R 80 Fittings'. Green coloured, injection moulded polypropylene fittings. For use with water up to 85°C.
‘RIALENE P 100 SGFxx KTW grau K 7-128, RIALENE P 100 SGFxx KTW weiß K 9-112, RIALENE P 100 SGFxx KTW schwarz’. Injection moulded polypropylene materials available in grey, white and black. The ‘xx’ in the material name can be replaced with any number between ‘10’ and ‘50’. For use with water up to 85°C.
'RAMOFIN PPH301G6NT'. White/beige coloured, injection moulded polypropylene material. For use with water up to 85°C.
'La.re.ter. s.p.A. PVC-U (RAL 7011) Pipe'. Grey coloured, extruded PVC pipe. For use with water up to 23°C.
'Timco Multi-Fix VESF'. Grey coloured, two-component chemical anchor resin. Mix in a 10:1 volume ratio. Apply as per manufacturer's instructions dated 25/09/2017. Cure for 7 days@7°C. For use with water up to 23°C. For use only as a resin anchor having been tested at a reduced surface area to volume ratio of 1,000mm² per 1 litre of water. This material is only approved for the mixing and curing conditions that appear on the approval. If the mix and cure conditions are varied from those specified on the approval then the material is not covered by the scope of the approval.
'Anchor Pro Plus'. Grey coloured, two-component chemical anchor resin. Mix in a 10:1 volume ratio. Apply as per manufacturer's instructions 'rev 02-2020' dated '2019-10-15'. Cure for 7 days@7°C. For use with water up to 23°C. For use only as a resin anchor having been tested at a reduced surface area to volume ratio of 1,000mm² per 1 litre of water. This material is only approved for the mixing and curing conditions that appear on the approval. If the mix and cure conditions are varied from those specified on the approval then the material is not covered by the scope of the approval.
'AT-HP/AT-HP Plus/S&P ResAC-19'. Grey coloured, two-component chemical anchor resin. Mix in a 10:1 volume ratio. Apply as per manufacturer's instructions dated 07/06/2018. Cure for 7 days@7°C. For use with water up to 23°C. For use only as a resin anchor having been tested at a reduced surface area to volume ratio of 1,000mm² per 1 litre of water. This material is only approved for the mixing and curing conditions that appear on the approval. If the mix and cure conditions are varied from those specified on the approval then the material is not covered by the scope of the approval.
'CHP-3-E'. Black coloured, injection moulded fluoroelastomeric material. Shore hardness 70. Tested in-radius size 3.95mm. For use with water up to 23°C.
‘EP4118F, EP4518F, EP5118F, EP5518F, EP6118F, EP6518F, EP6512F (also known as EP6512P), E7008F, EP7118F, EP7518F, EP8018F, EP8118F, EP8518F & EP9118F’. Range of black coloured, compression moulded, EPDM ‘O’ rings and gaskets. Shore hardness between 40 & 90. ‘O’ rings with tested in-radii sizes of between 0.25mm & 5.00mm. Gaskets with tested in-radii sizes of between 0.25mm & 7.50mm. For use with water up to 85°C.
'EP80/2 BLK 'O'-rings'. Black coloured, injection moulded EPDM 'O' rings. Tested in-radius size 1.5mm. For use with water up to 85°C.
'XX-02'. Black coloured, compression moulded EPDM rubber material. Shore hardness 50. Tested in-radius size 1.05mm. For use with water up to 85°C.
'EPDM G7005'. Black coloured, compression moulded EPDM rubber material. Shore hardness 70. Tested in-radius size 1.0mm. For use with water up to 23°C.
'EP500'. Black coloured, injection moulded EPDM rubber material. Shore hardness 70. Tested in-radius size 1.0mm. For use with water up to 85°C.
'WN60/1 BLK 'O' rings'. Black coloured, injection moulded NBR 'O' rings. Shore hardness 60. Tested in-radius size 1.31mm. For use with water up to 60°C.
`WN 22/1/9 BLK` 'O' rings. Black coloured, injection moulded, nitrile rubber 'O' rings. Shore hardness 70. Tested in-radius size 0.89mm. For use with water up to 65°C.
Bottom entry BS1212-4 (2016) compact type float operated valve for WC flushing cisterns. The inlet incorporates a plastic strainer. Maximum working pressure 10.0 bar. Cold water use only.
BS EN 14055: 2018 WC flushing cistern incorporating a side or bottom compact type float operated inlet valve providing a Type AG air gap with a dual flush drop valve (Phantom T & Phantom V) or dual flush syphon (Phantom S) for full flush volumes of up to 6 litres and a reduced flush of up to 4 litres. The cistern can be operated by lever or manual push button. Maximum working pressure 10.0 bar. Cold water use only.
Range of spring loaded, resilient trim, in-line check valve cartridges with plastic guide, stem and body with silicone or EPDM 'O'-rings. Maximum working pressure 16.0 bar. Maximum operating temperature 85°C for models 30.4010.0 and 40.4011.0. Maximum operating temperature 60°C for models 30.4043.0 and 30.4094.0.
Range of non-verifiable double check valve assemblies with DZR brass bodies, incorporating two spring loaded, resilient trim in-line check valve cartridges. Maximum working pressure 10.0 bar. Maximum operating temperature 85°C.
Non-verifiable double check valve assembly incorporating DZR brass (chrome plated) body two spring loaded, resilient trim in-line check valve cartridges & a drain port located between the cartridges. Maximum working pressure 10.0 bar. Maximum operating temperature 65°C.
Range of non verifiable double check valve assemblies consisting of two spring loaded resilient trim in-line check valve cartridges housed in a DZR brass body. The products incorporate a drain port between the cartridges. Maximum working pressure 16.0 bar. Maximum operating temperature 85°C.
Range of single hole, single outlet (fixed) over the rim (swivel nozzle) bidet combination tap assemblies (chromium plated brass) incorporating a ceramic cartridge headwork and either single lever or dome type operating members. The spout outlet incorporates a plastic aerator. Maximum working pressure 5.0 bar. Maximum operating temperature 85°C
Range of quarter turn ceramic disc headworks incorporating brass bodies and EPDM ‘O’ rings. Maximum working pressure 10.0 bar. Maximum operating temperature 85°C.
Range of quarter turn ceramic disc headworks with brass bodies, EPDM rubber ‘O’-rings and silicone rubber washers. Maximum working pressure 10.0 bar. Maximum operating temperature 85°C.
Range of quarter turn ceramic disc headworks incorporating brass or plastic bodies (HP-12 model only), NBR ‘O’-rings and silicone rubber washers. Maximum working pressure 10.0 bar. Maximum operating temperature 85°C.
Range of ceramic cartridge headworks with a plastic body and EPDM ‘O’-rings to be inserted into specifically dimensioned bodies. Maximum working pressure 10.0 bar. Maximum operating temperature 85°C.
Range of ceramic disc headworks with brass bodies and EPDM seals. Maximum working pressure 16.0 bar. Maximum operating temperature 85°C.
Range of single hole, single outlet (swivel) combination tap assemblies with brass bodies (various finishes), incorporating a pull out spray with push button trigger assembly and dome type operating member. The pull out spray also incorporates a single check valve assembly (however the complete unit has not been tested to demonstrate it provides adequate backflow protection). The outlets incorporate a plastic aerator. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.
Range of single hole, single outlet (fixed) combination tap assemblies with brass bodies (various finishes), incorporating ceramic cartridge headworks with single lever operating members. The spout outlets incorporate a plastic aerator. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.
Range of single hole, single outlet (fixed) combination tap assemblies (chromium plated brass), incorporating a ceramic cartridge headwork with single lever or dome type operating members. The spout outlets incorporate a plastic aerator. Maximum working pressure 5.0 Bar. Maximum operating temperature 85°C.
Range of single hole, single outlet (fixed) combination tap assemblies (chromium plated brass) incorporating a ceramic cartridge headwork with a single lever operating member. The spout outlets incorporate either a plastic flow straightener or aerator. The product is supplied with a click type waste. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.
Range of single hole, single outlet (fixed) combination tap assemblies (chromium plated brass), incorporating a ceramic cartridge headwork with either a dome type or single lever operating members. The spout outlet incorporates a plastic aerator. Maximum working pressure is 5.0 bar. Maximum operating temperature 60°C.
Single hole, single outlet fixed combination tap assembly (chromium plated brass), incorporating a ceramic cartridge headwork with a single lever operating member. The spout outlet incorporates a plastic flow straighteners Maximum operating pressure 5.0 bar. Maximum operating temperature 60°C
Single hole, single outlet fixed combination tap assemblies (chromium plated brass), incorporating a ceramic cartridge headwork with a single lever operating. The spout outlet incorporates a plastic flow straightener. Product is supplied with a pop up waste. Maximum operating pressure 5.0 bar. Maximum operating temperature 60°C
Range of single hole, single outlet (fixed) combination tap assemblies (in black or chrome finishes) with brass bodies. Incorporating ceramic cartridge headworks, and single lever operating members. The spout outlet incorporates a plastic aerator. Some models are supplied with a pop-up waste. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.
Single hole, single outlet (fixed) combination tap assembly incorporating ceramic cartridge headwork and single lever operating member. The spout outlet incorporates a plastic aerator. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.
Range of single hole, single outlet (fixed) combination tap assemblies with brass bodies (various finishes) incorporating ceramic cartridge headworks and single lever operating members. The spout outlets incorporate a plastic aerator. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.
Range of single hole, single outlet (fixed) combination tap assemblies incorporating ceramic cartridge headworks and single lever operating members. The spout outlets incorporate a plastic aerator. Models 53003 and 53005 are supplied with a pop-up waste. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.
Floor mounted, single outlet (fixed) combination tap assembly (chromium plated brass) incorporating a ceramic cartridge headwork with a single lever operating member and a self-cancelling diverter to shower outlet. The shower outlet incorporates an approved check valve cartridge however, the complete product has not been fully tested to demonstrate it provides backflow protection. The spout outlet incorporates a plastic aerator. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.
Range of single hole, single outlet (fixed) combination tap assembly with a brass body (various finishes), incorporating a ceramic cartridge headwork and single lever operating member with self- cancelling diverter to shower outlet. The spout outlet incorporates a plastic aerator. The diverter outlet incorporates an approved check valve cartridge however, the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.
Single hole, single outlet (swivel) combination tap assembly (chromium plated brass). Incorporating quarter turn ceramic disc headworks and single lever operating members. The spout outlet incorporates a plastic aerator. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.
Single hole, single outlet (swivel) combination tap assembly (chromium plated brass). Incorporating quarter turn ceramic disc headworks and single lever operating members. The spout outlet incorporates a plastic aerator. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.
Range of single hole, single outlet (swivel) combination tap assemblies with brass bodies (various finishes), incorporating ceramic cartridge headworks and single lever operating members. The spout outlet incorporates a plastic aerator. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.
Single hole, single outlet (swivel) combination tap assembly (chromium plated brass) incorporating quarter turn ceramic disc headwork with single lever operating members. The spout outlet incorporates a plastic aerator. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.
Range of single hole, single outlet (fixed) combination tap assemblies (chromium plated brass), incorporating ceramic cartridge headworks and single lever operating members. The spout outlets incorporate a plastic aerator. Model 1002137653_N199998998 is supplied with a pop up waste. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.
Single hole, single outlet (swivel) combination tap assembly (chromium plated brass), incorporating a ceramic cartridge headwork with a single lever operating member. The spout outlet incorporates a plastic aerator. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.
Single hole, single outlet (swivel) comination tap assembly (chromium plated brass). Incorporation a ceramic disc headwork with dome type operating members. The spout outlets incorporate a metal strainer and either a plastic aerator or alternative flow straightener. Maximum working pressure 10.0 bar. Maximum operating temperature 70°C.
Single hole, single outlet (swivel) comination tap assembly (chromium plated brass), incorporation a non-rising spindleheadwork with crosstop type operating members. The spout outlets incorporate a metal strainer and either a plastic aerator or alternative flow straightener. Maximum working pressure 10.0 bar. Maximum operating temperature 70°C.
Single hole, single outlet (swivel) comination tap assembly (chromium plated brass), incorporation a ceramic disc headwork with lever type operating members.The spout outlets incorporate a metal strainer and either a plastic aerator or alternative flow straightener. Maximum working pressure 10.0 bar. Maximum operating temperature 70°C
Single hole, wall mounted single outlet (swivel) combination tap assembly (chromium plated brass). Incorporating arising spindle headworks and cross top operating member. Maximum working pressure 8.6 bar. Maximum operating temperature 85°C.
Single hole, single outlet (swivel) combination tap assembly (chromium plated brass), incorporating ceramic cartridge headwork and single lever operating member. The spout outlet incorporates a plastic aerator. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.
Range of single hole, single outlet (swivel) combination tap assemblies (chromium plated brass), incorporating ceramic cartridge headworks and single lever operating members. The spout outlet incorporates a plastic aerator. The inlets incorporate an approved check valve cartridge, however, the complete product has not been fully tested to demonstrate it provides backflow protection Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.
Range of single hole, double outlet (swivel) combination tap assemblies with brass bodies (various finishes). Incorporating a non-rising spindle headwork with a dome type operating members. Maximum working pressure 10.0 bar. Maximum operating temperature 65°C.
Wall mounted, two hole, single outlet (fixed) combination tap assembly (chromium plated brass). Incorporating a ceramic cartridge headwork with lever or dome types of operating member. The spout outlet incorporates a plastic aerator. Maximum working pressure 5.0 bar. Maximum operating temperature 85°C.
Two hole, single outlet (fixed) combination tap assembly (chromium plated brass & matt black finishes) incorporating quarter turn ceramic disc headwork with single lever operating members. The spout outlets incorporate a metal strainer and either a plastic aerator or alternative flow straightener. The product is supplied with metal backnuts. Maximum working pressure 10.0 bar. Maximum operating temperature 70°C.
Range of wall mounted, two hole, single outlet (fixed) combination tap assemblies (chromium plated brass), incorporating quarter turn ceramic cartridge headworks with dome type operating member. The inlet incorporates a flow restrictor and the spout outlet incorporates a plastic flow straightener. Maximum working pressure 5.0 bar. Maximum operating temperature 80°C.
Range of deck mounted, two hole, single outlet (fixed) combination tap assemblies with brass bodies (various finishes), incorporating quarter turn ceramic disc headworks with single lever operating members or non-rising spindle headworks with cross top operating members (model CR26 & CR26/501). The spout outlet incorporates a plastic flow straightener (models CR26 & CR26/501 do not incorporate a flow straightener). The products are supplied with plastic backnuts. Maximum working pressure 10.0 bar. Maximum operating temperature 65°C.
Range of wall mounted, two hole, single outlet (fixed) combination tap assemblies with brass bodies (various finishes). Incorporating quarter turn ceramic disc headworks with single lever, dome or cross top operating members and manual diverters to shower outlets. This approval includes a hose, handset and wall bracket and the products are supplied with plastic backnuts. Maximum working pressure 6.0 bar. Maximum operating temperature 60°C.
Range of deck Mounted bar type thermostatic combination tap assemblies (chromium plated brass), incorporating a ½ turn ceramic disc headwork controlling the flow with either dome type (AR2 THBSM C & BWY AR2 THBSM C) or single lever (AR2 THLBSM C) operating members. The temperature is controlled independently via a thermostatic cartridge with either dome type (AR2 THBSM C & BWY AR2 THBSM C) or single lever (AR2 THLBSM C) operating members incorporating a manual override button. The product also incorporates a manual diverter between the spout outlet and shower outlet. The inlets incorporate a stainless steel strainer and an approved check valve cartridge however, the complete product has not been fully tested to demonstrate it provides backflow protection. The spout outlet incorporates a stainless steel strainer and a plastic flow straightener. Maximum working pressure 10.0 bar. Maximum operating temperature 65°C.
Range of wall mounted two-hole, single outlet (fixed) bath shower mixers with brass bodies (various finishes), incorporating a manual diverter controlling and diverting the flow between the spout outlet and an overhead shower. Temperature is controlled independently via a thermostatic cartridge with dome type operating member with manual override button. The spout outlets incorporate a plastic aerator. Each inlet incorporates an approved check valve cartridge, however, the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.
Two-hole, single outlet (fixed) combination tap assembly (chromium plated brass), incorporating quarter turn ceramic disc headwork with single lever operating members and a self-cancelling diverter to shower outlet. The spout outlet incorporates a plastic flow straightener and the product is supplied with a shower hose, shower handset and metal backnuts Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.
Two-hole, single outlet (fixed) combination tap assembly (chromium plated brass), incorporating quarter turn ceramic disc headwork with single lever operating members and a self-cancelling diverter to shower outlet. The spout outlet incorporates a plastic flow straightener. The product is supplied with a shower hose, shower handset and metal backnuts. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.
Two hole, single outlet (fixed) combination tap assembly (chromium plated brass), incorporating ceramic disc headworks with single lever operating members and a self-cancelling diverter to the shower outlet. The spout outlet incorporates a plastic flow straightener or optional aerator. The product is supplied with a shower hose, shower handset and metal backnuts. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.
Wall mounted, two-hole, single outlet (fixed) combination tap assembly (chromium plated brass) incorporating quarter turn ceramic disc headworks with dome type operating members, the temperature is controlled independently via a thermostatic cartridge with single lever operating members with a manual override button and a self-cancelling diverter to shower outlet. The spout outlet incorporates a plastic aerator. Inlets incorporate stainless steel strainers approved check valve cartridges, (however, the complete product has not been fully tested to demonstrate it provides backflow protection). Maximum working pressure 5.0 bar. Maximum operating temperature 85°C.
Range of wall mounted two hole, single outlet (fixed) combination tap assemblies (chromium plated brass), incorporating a ceramic cartridge headworks with single lever operating member and self-cancelling diverter to shower outlet. The inlets incorporate a stainless steel strainer and an approved check valve cartridge, however, the complete product has not been fully tested to demonstrate it provides backflow protection. The spout outlet incorporates a plastic aerator. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.
Single hole, single outlet, swivel combination tap assembly (chromium plated brass) incorporating ¼ turn ceramic disc headworks with single lever operating members. The spout outlet incorporates a plastic aerator. Maximum working pressure 5.0 bar. Maximum operating temperature 60 °C.
Range of concealed wall mounted bath shower mixers (brass body) incorporating a manual diverter to bath or shower handset. Flow is controlled by cartridge headworks using single lever type or dome operating members. Temperature is independently controlled via a single lever or dome type operating member incorporating a manual override button. Manual diverter is also controlled by single lever or dome operating members. The spout outlets incorporate a plastic aerator. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.
Range of standpipes for bath/showers with a brass body (various finishes, see model). The standpipes incorporate an approved flexible hose. Maximum working pressure 10.0 bar. Maximum operating temperature 70°C.
Range of spout outlets incorporating brass bodies and NBR ‘O’-rings. The spout outlets incorporate a plastic flow straightener. Models AX-SIR-140/RO/DIV and AX-BOK-140/SQ/DIV incorporate a self-cancelling diverter. Maximum operating temperature 60°C.
`Wellmate` range of expansion vessels with plastic bodies and rubber diaphragms Maximum working pressure 8.6 Bar, cold water use only.
‘Copper press fittings - M Profile’ range of press fittings with a brass body and EPDM ‘O’-rings for use with copper pipe manufactured to EN1057:2006 +A1:2010 seamless round copper tube R250. Joints are achieved using a specialist press fitting tool. Maximum working pressure 16.0 bar. Maximum operating temperature 85°C.
“Plimat PVC-U Fittings BS Inch and PVC-U Fittings Threaded” range of PVC-U solvent cement or threaded fittings for use with “Plimat PVC-U BS inch pipe” (manufactured to EN1452-2). Maximum working pressure 15.0 bar for solvent cement connections and 10.0 bar for fittings that only include/also include a threaded connection. Cold water use only.
'ALTOPOLY PB pipe'. Grey coloured, extruded multi-layered pipe consisting of a polybutylene inner and outer layer and a dark grey coloured EVOH middle barrier layer and 'ALTOPOLY EVOH PEX Pipe'. Extruded, multi-layered pipe consisting of a white coloured PEX inner, blue coloured EVOH middle layer and white coloured PEX outer. For use with SNC Corporation ‘Twistloc’ push-fit fittings covered by WRAS approval 1904906. Maximum working pressure 10.0 bar. Maximum operating temperature 85°C.
Uponor S-Press press fittings, Uni-X & Uni-C compression fittings for use with Uponor MLC pipe. Maximum working pressure 10.0 bar, maximum operating temperature 70°C.
‘CB ISR’ range of capillary fittings with internal solder rings, DZR brass or gunmetal capillary, lead free solder ring and threaded fittings for use with copper pipe. For above ground use only. Maximum working pressure 16.0 bar. Maximum working temperatures 99°C.
Range of copper and bronze capillary brazed fittings for use with copper pipe manufactured to EN1057:2006 +A1:2010. Maximum pressure 10.0 Bar (54mm up to and including 108mm) Maximum pressure 2.0 Bar (Over 108mm up to and including 159mm) Maximum operating temperature 100°C.
Range of compression fittings with polypropylene bodies, nuts, acetal grip rings, EPDM ‘O’-rings and plastic pipe liners for use with MDPE pipe manufactured to BS EN 12201. For above and below ground use. Maximum working pressure 16.0 bar. Cold water use only.
“Plimat ABS Fittings BS Inch and ABS Adaptor Fittings” range of ABS solvent cement or threaded fittings for use with “Plimat ABS pipe”. Maximum working pressure: 15.0 bar (fittings with ½” - 4” solvent cement connections), 9.0 bar (fittings with 5” or 6” solvent cement connections, with or without threaded connecitons), and 10.0 bar (fittings with threaded connections and ½” - 4” solvent cement connections). Cold water and above ground use only.
Range of PSU, POM & DZR brass pushfit fittings for use with PE-x pipe (manufactured to BS7291-3), PB pipe (manufactured to BS7291-2) & copper pipe. Maximum working pressure 10.0 bar @ 65°C (PSU & DZR Brass Fittings). Open outlet use only @ 20°C (POM Fittings).
Range of press fittings incorporating copper or copper alloy bodies and EPDM O’-rings for use with copper tube to EN1057. Maximum working pressure 16.0 bar. Maximum operating temperature 85°C.
Range of floor standing commercial glass washers incorporating a solenoid valve controlling the flow. The product is supplied with a double check valve assembly (suitable for backflow protection against fluid category 3). Maximum working pressure 4.0 Bar. Maximum operating temperature 60°C.
Range of indirect heat interface units providing heating and instantaneous hot water. The hot water and space heating is provided via two separate plate heat exchangers. The space heating circuit incorporates an expansion vessel and expansion relief valve (set @ 3.0 bar). The primary circuit only is supplied with isolation valves on the flow and return. Maximum working pressure primary 16.0 bar. Maximum working pressure space heating 2.5 bar. Maximum working pressure secondary hot water (DHW) 10.0 bar. Maximum operating temperature primary 75°C. Maximum operating temperature space heating 85°C. Maximum operating temperature secondary hot water (DHW) 65°C.
Range of stainless-steel plate heat exchangers with copper brazing. Maximum working pressure 30.0 Bar. Maximum operating temperature 100°C.
Range of copper brazed stainless-steel heat exchangers. Maximum working pressure 30.0 bar. Maximum operating temperature 100°C.
Range of stainless steel, copper brazed plate type heat exchangers. Maximum working pressure 30.0 bar. Maximum operating temperature 100°C.
Electronically controlled heat interface units (HIU) with twin stainless-steel plate heat exchangers providing space heating and instantaneous hot water. The cold inlet supply to the plate heat exchanger incorporates an isolation valve. The space heating circuit incorporates an expansion vessel and a pressure relief valve (set at 3.0 bar). The inlet and outlet of all circuits incorporates lever operated spherical valves with brass bodies. 274.xx9x.696 models all have the following additional items over the 274.xx1x.696 models: Heatmeter on the primary circuit, a flushing bypass between the primary and space heating circuits and a safety relief valve (set at 10.0 bar) on the cold supply to the heat exchanger of the domestic hot water circuit. Maximum working pressures and operating temperatures: Primary: 16.0 bar and 90˚C. Domestic hot water (DHW): 9.5 bar and 60˚C. Secondary (space heating): 2.5 bar and 85˚C.
Range of water meters with plastic bodies and EPDM ‘O’-rings. The inlets incorporate a plastic strainer. Maximum working pressure 10.0 bar. Cold water use only.
Range of shock arrestors with carbon steel or stainless steel bodies (available in various external surface finishes) incorporating Bromobutyl (BIIR) membranes. Maximum working pressure 10.0 bar. Cold water use only.
Range of shock arrestors with stainless steel bodies incorporating Bromobutyl (BIIR) membranes. Maximum working pressure 10.0 bar. Cold water use only.
Air break to drain, incorporating brass bodies with a grey epoxy powder coating. Maximum operating temperature 60°C.
Impeller with plastic body for insertion into specifically dimensioned bores. Maximum operating temperature 70°C.
Wall mounted chrome plated brass elbow fitting. Maximum working pressure 5.0 bar. Maximum operating temperature 70°C.
Hygienic flush box providing a timed flush facility. The supply is via a single check valve cartridge however, the complete product has not been fully tested to demonstrate it provides backflow protection, flow sensor, spherical ball valve and strainer. The products incorporate a type `AB` airgap (verified by test - suitable for backflow protection against fluid category 5). The units have multiple interface user functions for timed flush, wireless technology and data storage. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.
Maincor Manifold having a brushed chrome plated body with 2 ,3 or 4 ports each with an isolation valve with red or blue indicators for hot and cold feeds. Supplied with a blanking plug and nut. Maximum working pressure 6.0 bar. Maximum operating temperature 75°C.
Pent-A-Boost domestic break tank and booster set incorporating a single or dual pump stage pump set assembly and break cistern (incorporating an AG air gap arrangement). Inlet level sensors control the water supply via solenoid valves with inline strainers fitted (see manufacturers data sheet for optional arrangements). The unit also incorporates an expansion vessel. Flow from the break tank is via a single check valve suitable for fluid category 2 to a booster pump arrangement (see manufacturers data sheet for optional arrangements). Maximum working pressure 10 bar. Cold water use only.
“Yonos PARA Z15 and Yonos PARA Z25 ” range of circulation pumps incorporating brass bodies, plastic impellers and EPDM ‘O’-rings. Maximum working pressure 10.0 bar. Maximum operating temperature 95°C.
Range of single and twin ended shower booster pumps with plastic bodies and plastic impellers. The inlets/outlets incorporate stainless steel braided EPDM lined flexible hose assemblies with isolation valves and stainless steel strainers. The outlets incorporate approved check valve cartridges however, the complete product has not been fully tested to demonstrate it provides backflow protection. The Universal Twin models incorporate an expansion vessel. Maximum working pressure (See model). Maximum operating temperature 60°C.
Range of shower handsets incorporating ABS bodies (chrome plated), EPDM seals and ‘O’-rings. Maximum operating temperature 65°C.
Wall mounted vandal resistant shower head with (chrome plated brass finish). The inlet incorporates an approved check valve cartridge however, the complete product has not been fully tested to demonstrate it provides backflow protection. The outlet incorporates a plastic aerator. Open outlet use only. Maximum operating temperature 60°C.
A range of shower handsets with chromium plated plastic bodies and a plastic strainer and flow regulator in the inlet. Models may incorporate dark grey alternative shower plate. Maximum operating temperature 85°C.
Overhead, ceiling mounted shower outlet with chromium plated brass body (various finishes). Maximum operating temperature 60°C.
Shower handset incorporating a plastic body (chrome plated), brass wall connector (chrome plated) and shower hose. The inlet to the shower and wall connector incorporates approved check valve cartridges, however, the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum operating temperature 60°C.
Range of over head shower outlets incorporating brass bodies and an adjustable ball joint. The inlet incorporates a combined NBR washer and stainless-steel filter. Maximum operating temperature 60°C.
Range of in-line `Y` pattern strainers incorporating DZR brass bodies, stainless steel mesh strainers and white PTFE gaskets. Maximum working pressure 25.0 bar. Maximum operating temperature 85°C.
Range of in-line `Y`-patterned strainers with either brass or DZR brass bodies (see model) incorporating a stainless steel mesh strainer and a PTFE washer. Maximum working pressure 25.0 Bar. Maximum operating temperature 99.0°C
In-line `Y`-patterned strainers with bronze bodies incorporating stainless steel mesh strainers and PTFE washers. Maximum working pressure 20.0 bar. Maximum operating temperature 85.0°C
Drain off valve with brass body (chrome plated) and NBR ‘O’-rings. Maximum working pressure 16.0 bar. Maximum operating temperature 99°C.
Pillar tap with brass body (various finishes), incorporating a quarter turn ceramic disc headwork and cross top operating member. The spout outlet incorporates an aerator. Maximum working pressure 10.0 bar. Maximum operating temperature is 60°C.
Basin pillar taps (chrome plated brass) with quarter turn ceramic disc headwork and single lever or cross top operating members. The spout outlets incorporate a plastic flow straightener. The product is supplied with plastic backnuts. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.
Range of wall mounted taps (chromium plated brass) incorporating non-rising spindle headworks with cross top operating members. Maximum working pressure 10.0 bar. Maximum operating temperature 65°C.
Range of pillar taps (chromium plated brass) incorporating non rising spindle headworks and cross top operating members. The spout outlets incorporate a plastic flow straightener. The products are supplied with metal backnuts. Maximum working pressure 10.0 bar. Maximum operating temperature 65°C.
Range of pillar taps (chromium plated brass) incorporating non rising spindle headworks and cross top operating members. The spout outlets incorporate a plastic flow straightener. The products are supplied with metal backnuts. Maximum working pressure 10.0 bar. Maximum operating temperature 65°C.
Range of stainless steel braided, white (translucent) polyethylene lined (CPWX models) or white elastomeric thermoplastic (TPSiV) lined (SPWX models) flexible hose assemblies. Hoses are available with a variety of end connections (see model), either brass or nickel plated brass (SPWX/CPWX10 models). Maximum working pressures 10.0 bar. Maximum operating temperature 90°C.
Range of EPDM or PEX inner, stainless steel flexible hoses with EPDM gaskets. Maximum working temperature is 70°C.
‘TAQ PEX’ range of PEX lined flexible hose assemblies with either stainless steel braiding or grey polymeric (PET - Polyethylene terephthalate) braiding (ACB suffix models). Models have either EPDM ‘O’-rings and/or EPDM or silicone washers (depending on end connection). Models are also available with an optional washer incorporating a stainless steel strainer. Maximum working pressure 10.0 bar. Maximum operating temperature 85°C.
Range of brass bodied automatic air venting valves incorporating a plasitc float. The D2004 models are supplied with an isolation valve, comprising of a brass body with a plastic plunger, spring, NBR ‘O’-ring and PTFE seal. The plunger is pushed open when the air venting valve is attached and the spring closes it when the air venting valve is removed. Maximum working pressure 10.0 bar. Maximum operating temperature 110°C.
Range of brass bodied automatic air venting valves incorporating a plasitc float. The FIG 776 models are supplied with an isolation valve, comprising of a brass body with a plastic plunger, spring, NBR ‘O’-ring and PTFE seal. The plunger is pushed open when the air venting valve is attached and the spring closes it when the air venting valve is removed. Maximum working pressure 10.0 bar. Maximum operating temperature 110°C.
Wall mounted, concealed, thermostatic shower blending valve (brass bodies). The product has two outlets, each controlled by a detent (push to on, push to off) headwork. Temperature is controlled independently via a thermostatic cartridge, (no operating member supplied). Each inlet incorporates a stainless steel strainer and an approved check valve cartridge, however, the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum working pressure 10.0 bar. Maximum operating temperature 85°C.
Range of shower kits consisting of a deck mounted thermostatic shower mixer with brass bodies (chrome plated), incorporating a ceramic disc headworks controlling the flow with a dome type operating member and a manual diverter to shower outlet. Temperature is controlled independently via a thermostatic cartridge with a dome type operating member that also incorporates a manual override button. Both inlets incorporate a single check valve cartridge (however, the complete product has not been fully tested to demonstrate it provides backflow protection) and stainless-steel strainers. The spout outlet incorporates a plastic aerator. Supplied with a shower hose & shower handset. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.
Range of deck mounted thermostatic shower mixing valves with brass bodies (chrome plated), incorporating a ceramic disc headworks controlling the flow with a dome type operating member and a manual diverter to shower outlet. Temperature is controlled independently via a thermostatic cartridge with a dome type operating member that also incorporates a manual override button. Both inlets incorporate a single check valve cartridge (however, the complete product has not been fully tested to demonstrate it provides backflow protection) and stainless-steel strainers. The spout outlet incorporates a plastic aerator. Models TLVEFLF, SHTLV106/1BK, PP SHTLV106/1BK & SHTLV106/2BK are supplied with a shower hose & shower handset, riser rail & soap tray. Model TLV106 is supplied with a shower hose & shower handset. All models are supplied with metal backnuts. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.
Range of wall mounted, bar-type thermostatic shower valves with brass bodies (chromium plated), incorporating a non-rising spindle headwork controlling the flow with a dome type operating member. Temperature is controlled independently via a thermostatic cartridge using a dome type operating member which incorporates a manual override button. Both inlets incorporate a stainless steel strainer and an approved check valve cartridge, however, the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum working pressure 10.0 bar. Maximum operating temperature 85°C.
Range of wall mounted concealed thermostatic shower valves (brass bodies), incorporating a ceramic disc controlling the flow. The temperature is controlled independently via a thermostatic cartridge, using dome type operating members incorporating a manual override button. The inlets incorporate an approved single check valve cartridge however, the complete assembly has not been fully tested to demonstrate that it provides adequate backflow protection. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C
Range of wall mounted thermostatic shower valves with brass bodies (chromium plated) incorporating a ceramic disc controlling the flow to the overhead shower using a dome type operating member. The temperature is controlled independently via a thermostatic cartridge with a dome type operating member incorporating a manual override button. Inlets incorporate stainless steel strainers and approved single check valve cartridges however, the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C
Range of wall mounted thermostatic blending valves (chromium plated brass) incorporating either a 2 way ceramic disc diverter (models T43014, T44014 & T45004) controlling the flow to either an overhead shower or shower handset with various operating members (See model) or a quarter turn ceramic disc headwork (models T43014B, T43034 & T44014B) with various operating members. The temperature is controlled independently via a thermostatic cartridge incorporating a manual override button. The inlets incorporate approved check valve cartridge(s), however, the complete product has not been fully tested to demonstrate it provides backflow protection and stainless steel strainers. Maximum working pressure 5.0 bar. Maximum operating temperature is 85°C.
Shower kit consisting of a wall mounted thermostatic blending valve with a brass body (chrome plated), incorporating a single sequential headwork controlling both temperature and flow using a single lever operating member. Each inlet incorporates a stainless steel strainer and an approved check valve cartridge, however, the complete product has not been fully tested to demonstrate it provides backflow protection. The product is supplied with shower hose, shower handset & riser rail. Maximum working pressure 5.0 bar. Maximum operating temperature 70°C.
Shower kit consisting of a wall mounted thermostatic blending valve with a brass body (chrome plated), incorporating a single sequential headwork controlling both temperature and flow using a single lever operating member. Each inlet incorporates a stainless steel strainer and an approved check valve cartridge, however, the complete product has not been fully tested to demonstrate it provides backflow protection. The product is supplied with shower hose, shower handset, riser rail & soap tray. Maximum working pressure 5.0 bar. Maximum operating temperature 70°C.
Shower kit consisting of a wall mounted (concealed or exposed) thermostatic blending valve with a brass body (chrome plated). Flow is controlled by a quarter turn ceramic disc headwork with single lever operating member, temperature is controlled by a thermostatic cartridge with a dome type operating member which incorporates a manual override button. Each inlet incorporates a stainless steel strainer and an approved check valve cartridge, however, the complete product has not been fully tested to demonstrate it provides backflow protection. The product is supplied with shower hose, shower handset, riser rail & soap tray. Maximum working pressure 10.0 bar. Maximum operating temperature 70°C.
Shower kit consisting of a wall mounted (concealed or exposed) thermostatic blending valve with a brass body (chrome plated). Flow is controlled by a quarter turn ceramic disc headwork with single lever operating member, temperature is controlled by a thermostatic cartridge with a dome type operating member which incorporates a manual override button. Each inlet incorporates a stainless steel strainer and an approved check valve cartridge, however, the complete product has not been fully tested to demonstrate it provides backflow protection. The product is supplied with shower hose, shower handset & riser rail. Maximum working pressure 10.0 bar. Maximum operating temperature 70°C.
Shower kit consisting of a wall mounted thermostatic blending valve with a brass body (chrome plated), incorporating quarter turn ceramic disc headwork which controls the flow with dome operating members, temperature is controlled independently via a thermostatic cartridge with dome type operating member which incorporate a manual override button.. Each inlet incorporates an approved check valve cartridge, however, the complete product has not been fully tested to demonstrate it provides backflow protection. The product is supplied with shower hose, shower handset, riser rail. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.
Wall mounted (vertical) thermostatic blending valve (chromium plated brass) incorporating a non-rising spindle headwork controlling the flow with a dome type operating member. The temperature is controlled independently via a thermostatic cartridge with a dome type operating member that also incorporates a manual override button. The inlets incorporate stainless steel strainers and an approved check valve cartridge however, the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum working pressure 10.0 bar. Maximum operating temperature 65°C.
Range of two hole wall mounted thermostatic bar type mixing valves with a chrome plated brass body, incorporating a quarter turn ceramic disc headwork with dome type operating member. The temperature is controlled independently via a thermostatic cartridge with dome type operating member that incorporates a manual override button. Inlets incorporate stainless steel strainers and approved check valve cartridges however, the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum working pressure 8.0 bar. Maximum operating temperature 60°C.
Range of single hole, single outlet, manually operated flow control valve (brass bodies) incorporating a quarter turn ceramic disc headwork housed and supplied with either single lever, dome type or cross top (see model) operating members. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C
‘GNVP’ range of non-return valves with a black or white plastic housing, (white added October 2024). The product incorporates two test/drainage plugs. Maximum working pressure 16.0 bar. Maximum operating temperature 60°C.
Range of in-line adjustable pressure reducing valves, with bronze bodies and NBR gaskets. The products are supplied with an optional pressure gauge. Maximum inlet supply pressure 20.0 bar. Outlet pressure in the range of 1.0 bar to 4.0 bar. Maximum operating temperature 85°C.
Range of adjustable in-line pressure reducing valves with bronze bodies and manually operated pressure reducing mechanism. Outlet pressure adjustable between 1.5 to 6.0 bar. Maximum supply pressure 16.0 bar. Maximum operating temperature 60°C.
Range of adjustable, in-line pressure reducing valves incorporating gunmetal bodies and EPDM diaphragm & ‘O’-rings. Maximum inlet supply pressure 16.0 bar. Maximum outlet pressure 1.5 to 5.5 bar. Cold water use only.
Range of pressure relief valves incorporating brass bodies and EPDM rubber washers. The valves incorporate a manually operated rotational easing gear. For maximum working pressure please refer to model. Maximum operating temperature 99°C.
Range of latching and non-latching normally closed solenoid valves with either brass or stainless-steel bodies. Please refer to model for maximum working pressure. Maximum operating temperature 85°C.
Range of latching solenoid valves with brass bodies, incorporating stainless steel strainer with EPDM O rings and diaphragms Maximum working pressure 12.0 Bar or 16.0 Bar on (SCPH262C020 & SCPXH262C020BW TPL 21896 Only). Maximum operating temperature 85.0°C
Spherical valves incorporating bronze bodies with lever operating members, chromium plated brass ball and PTFE seat. Maximum working pressure 25.0 bar, Maximum operating temperature 85°C.
Range of spherical valves with single lever or butterfly operating member, bronze bodies, bronze ball. Maximum working pressure 40.0 bar Maximum operating temperature 85 ºC.
Spherical valves incorporating bronze bodies with lever operating members, chromium plated brass ball and PTFE seat. Maximum working pressure 25.0 bar, Maximum operating temperature 85°C.
‘Aladdin Easyfit Isolator’, lever operated isolation valve with a stainless steel body, brass plug, chrome plated brass spindle, EPDM boot gasket and seals, NBR ‘O’-rings, and a stainless steel cutter to enable a connection to a pressurised or wet system. For use on 28mm diameter copper pipe manufactured to EN1057 only. Maximum working pressure 16.0 bar. Maximum operating temperature 85°C.
Spherical valves incorporating bronze bodies with lever operating members, chromium plated brass ball and PTFE seat. Maximum working pressure 25.0 bar, Maximum operating temperature 85°C.
Range of spherical ball valves with single lever or T-handle operating members, brass bodies (nickel plated) and chromium plated brass ball and PTFE washers. Maximum working pressure IN90 models = 40.0 bar. IN89 models = 25.0 bar. Maximum operating temperature 85.0°C
Range of electrically actuated ball valves incorporatingstainless steel bodies and ball with PTFE seat. Various closure options are available depending on model. Maximum working pressure 10.0 bar. Maximum operating temperature 100°C.
Angled spherical valve with brass body, brass ball (chrome plated), and screwdriver operating member. Maximum working pressure 10.0 bar. Maximum operating temperature 85°C.
Range of gate valves incorporating either rising or non-rising spindle headworks and PTFE gaskets. The products are available as follows: Brass body, brass wedge and handwheel (ART325 RS models). Bronze body, bronze wedge and handwheel (ART330 HW models) or lockshield operating member (ART330 LS models). Maximum working pressure 20.0 bar. Maximum operating temperature 85°C.
Range of gate valves with bronze bodies with metal seats. The valves operate via a non-rising spindle headworks that incorporate a wheel type operating member or lock shield type (see models) Maximum working pressure 20.0 bar. Maximum operating temperature 85°C
Range of gate valves with blue epoxy coated ductile iron bodies, EPDM coated ductile iron wedges. The valves operate via a non-rising spindle headwork with hand wheel operating member. Maximum working pressure 16.0 bar. Maximum operating temperature 85°C.
Range of gate valves (gunmetal) with gunmetal bronze wedges, brass spindle and PTFE seals. Maximum working pressure 20.0 bar. Maximum operating temperature 100°C.
Range of gate valves incorporating bronze bodies and wedges with PTFE seals. The valves are operated via a non-rising spindle with a hand wheel operating member. Maximum working pressure 20.0 bar. Maximum operating temperature 85°C.
Range of screw down stop valves with brass bodies and PTFE seals. For use with copper pipe to EN1057. Maximum working pressure 16.0 bar. Maximum operating temperature 65ºC.
Screw down stop valve (chromium plated brass) incorporating a dome (triangular) type operating member with a NBR rubber washer. Maximum working pressure 10.0 bar. Maximum operating temperature 85.0°C
Range of double regulating valves with bronze bodies, PTFE disc face and orifice plate, and EPDM rubber ‘O’-rings with thermostatic control elements and a manually adjustable flow control valve. Maximum working pressure 25.0 bar. Maximum operating temperature 85°C.
Range of inline water meter kits incorporating brass bodies, a spherical valve and drain off valve. Maximum working pressure 10.0 bar. Cold water use only.
'Iupital F10-02 nat, Iupital F20-03 nat & Iupital FG2025 nat (white coloured). Iupital F10-02 E9000 black & Iupital F20-03 E9001 black (black coloured)'. Injection moulded acetal materials, (manufactured in Bangkok, Thailand). For use with water up to 85°C.
'Delrin® FG100P NC010'. White coloured, injection moulded acetal material. For use with water up to 23°C.
'P5600' (impregnated with phenolic resin) & 'P8412' (impregnated with epoxy resin). Black coloured, impregnated carbon graphite washers. For use with water up to 85°C.
'Polyglass VEF'. Factory applied, cream coloured, vinyl ester coating. Apply as per manufacturer's instructions '2/23 A' last reviewed July 2020. Cure for 7 days@21°C. For use with water up to 23°C. This material is only approved for the curing conditions that appear on the approval. If the cure conditions are varied from those specified on the approval then the material is not covered by the scope of the approval.
'Excellube G300'. Factory applied, grey coloured PTFE coating. Apply as per manufacturer's instructions 'revision No:1' dated 15/10/2020. Cure for 20 minutes@240°C. For use with water up to 85°C. This material is only approved for the curing conditions that appear on the approval. If the cure conditions are varied from those specified on the approval then the material is not covered by the scope of the approval.
‘Intercrete 4820’. Site applied, grey coloured waterproof mortar. Mix Intercrete 4820 & water in a mass ratio of 8.33:1. Cure for 21 days@7°C. For use with water up to 23°C. This material is only approved for the curing conditions that appear on the approval. If the cure conditions are varied from those specified on the approval then the material is not covered by the scope of the approval.
'Lewatit S 1568, Lewatit S 1567 & Lewatit MonoPlus S107 NS'. Brown coloured, translucent ion exchange resins. For use with water up to 23°C
'Grivory GV XE 10726 Black 9225'. Black coloured, injection moulded, glass reinforced polyamide material. For use with water up 23°C.
'TECHNYL ® SAFE A 219WFC V30 BK’ (black coloured) & ‘TECHNYL ® SAFE A 219WFC V30 NC’ (natural, appears off-white). Injection moulded, glass fibre reinforced polyamide 6.6 materials. For use with water up to 85°C.
'PolyPol-1015'. Orange coloured, contact moulded, unsaturated polyester resin material. For use with water up to 50°C.
'Ketaspire KT-820 NT & KT-820 NL PEEK'. Beige coloured, injection moulded PEEK materials. For use with water up to 85°C.
'Cosmoplast HDPE & MDPE Pipes'. Black coloured, extruded polyethylene pipes. For use with water up to 60°C.
'Radel R-5100 GY 1037 (grey coloured), R-5100 GY1037 ECHO RP (grey coloured), R-5100 BK 937 (black coloured), R-5100 BK937 ECHO RP (black coloured) & R-5500NT (translucent)' - (manufactured in Oudenaarde, Belgium, Marietta, Ohio & RTP Company, USA). ‘R-5100 BU 1197 (blue coloured), R-5100 NT 15, R-5000 NT, R-5000 NT ECHO RP (natural), R-5100 NT ECHO RP (natural) & R-5100 NT (NT grades are natural and appear cream coloured, opaque)’ -(manufactured in Marietta, Ohio). ‘R-5100 GY1037LF’ (grey coloured - manufactured in Oudenaarde, Belgium and Marietta, Ohio). In July 2024, ‘Radel R-5100 GY1037 LF ECHO RP’ (grey coloured - manufactured in Oudenaarde, Belgium and Marietta, Ohio) was added to the approval. In November 2024, Radel R-5100 NT15 ECHO RP (NT grades are natural and appear cream coloured, opaque) & Radel R-5100 BU 1197 ECHO RP (blue coloured) were added to the approval. Injection moulded, polyphenylsulfone materials. For use with water up to 85°C.
‘Udel P-3500 NT LCD, GF-110 NT, GF-120 NT, GF-121 NT, P-1700 NT 11 MR & P-1700 NT 11’ (all beige translucent). ‘Udel P-1700 Grey 8057’ (grey coloured). ‘Udel P-1700 BK 937, P-1700 BK 937 MR, GF-120 BK 937 & GF-121 BK 937’ (all black coloured). ‘P-1700 WH 7407’ (white coloured). ‘Udel GF-121 BK 937 ECHO RP’ (black), ‘Udel GF-121 NT ECHO RP’ (beige translucent) & ‘Udel P-3500 NT LCD ECHO RP’ (beige translucent) were added to the approval in November 2024. ‘Udel GF-120 K 937 ECHO RP’ (black coloured) was added to the approval in April 2025. Injection moulded, polysulphone materials. For use with water up to 85°C.
'E44'. Black coloured, injection moulded EPDM sealing ring. Shore hardness 70. Tested in-radius size 1.5mm. For use with water up to 85°C.
'YL-E-7010'. Black coloured, compression moulded EPDM material. Shore hardness 70. Tested in-radius size 1.0mm. For use with water up to 60°C.
'E7581'. Black coloured, injection moulded EPDM rubber material. Shore hardness 70. Tested in-radius size 1.0mm. For use with water up to 85°C.
Press moulded, solid silicone rubber materials. Tested in-radius size 1.0mm. For use with water up to 85°C. ‘72401’ (red coloured) & ‘72501’ (blue coloured). Shore hardness 20. ‘73401’ (red coloured) & ‘73501’ (blue coloured). Shore hardness 30. ‘74401’ (red coloured) & ‘74501’ (blue coloured). Shore hardness 40. ‘75401’ (red coloured) & ‘75501’ (blue coloured). Shore hardness 50. ‘76401’ (red coloured) & ‘76501’ (blue coloured). Shore hardness 60. ‘77401’ (red coloured) & ‘77501’ (blue coloured). Shore hardness 70. ‘78401’ (red coloured) & ‘78501’ (blue coloured). Shore hardness 80. ‘79401’ (red coloured) & ‘79501’ (blue coloured). Shore hardness 90.
'Beaulon P5250N Grey & Beaulon P5250N White'. Compression moulded, thermoplastic Polybutene materials. For use with water up to 85°C.
Range of wall hung WC pan with bidet seat where the flow is controlled via a solenoid valve and discharges via a type `AB` airgap (verified by test - suitable for backflow protection against fluid category 5). Cold supply only. Maximum working pressure 10 bar.
Range of wall hung WC pans with bidet seat where the flow is controlled via a solenoid valve and discharges via a type `AB` airgap (verified by test - suitable for backflow protection against fluid category 5). The unit has a heated seat and dryer function. Cold supply only Maximum working pressure 10.0 bar.
`JRW AA 512-UK diaphragm`. Black coloured, injection moulded butyl rubber diaphragm. Shore hardness 60. Tested in-radius size 1.0mm. For use with water up to 60°C.
Single hole, single outlet (fixed) electronically controlled tap assemblies (chromium plated brass), flow is controlled by a solenoid valve activated via an infra-red sensor. The tap connects to the solenoid valve via a copper tail with a ½” BSP (F) captive nut and a fibre washer. The product is supplied with a combined TPE washer and stainless steel strainer to be installed on the inlet to the solenoid. The spout outlets incorporate a plastic flow straightener. Maximum working pressure 8.0 bar. Maximum operating temperature 60°C.
Range of deck mounted, three-hole, single outlet (fixed) combination tap assemblies (chromium plated brass), incorporating a ceramic cartridge headwork and manually operated diverter valve, both models RAKSOR3013C and RAKPOR3013C use single lever operating members and model RAKAMA3013C has a dome type operating member. The spouts incorporate a plastic aerator. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.
Type `AB` airgap (verified by test - suitable for backflow protection against fluid category 5) and flexible hose. Flow is controlled via a solenoid valve. Maximum working pressure 4.0 bar. Maximum operating temperature 55°C
Spring loaded, resilient trim, in-line check valve cartridge with plastic guide, stem, body and EPDM O-rings. Maximum working pressure 16.0 bar. Maximum operating temperature 85°C.
Adaptor, with DZR brass body (chrome plated), which incorporates a single check valve cartridge verified by test (as suitable for backflow protection against Fluid Category 2). Maximum working pressure 16.0 bar. Maximum operating temperature 85°C.
Single check valve assembly with a brushed nickel coated DZR brass body, incorporating a screwdriver operated isolation valve and EPDM ‘O’ rings. Maximum working pressure 10.0 bar. Maximum operating temperature 85ºC.
Range of double check valve assemblies consisting of two spring loaded resilient trim in-line check valve cartridges housed in a DZR brass body (chromium plated), incorporating an isolation valve with a brass ball and PTFE gaskets. Maximum working pressure 10.0 bar. Maximum operating temperature 85°C.
Range of non-verifiable double check valve assemblies, consisting of two spring loaded resilient trim in-line check valve cartridges housed in DZR brass bodies (brushed chrome plated) with a drain port located between the cartridges either at the top or bottom. Models incorporate an isolation valve with either lever or butterfly handles. Maximum working pressure 10.0 bar. Maximum operating temperature 85°C.
`Silverline` range of sectional hot-pressed GRP cold water storage cisterns with butyl seals and stainless-steel bolts and tie rods. Supplied with WRAS approved byelaw 30 kits Cold water use only.
Range of ceramic cartridge headworks incorporating plastic bodies and silicone ‘O’-rings, to be inserted into specifically dimensioned bodies. Maximum working pressure 16.0 bar. Maximum operating temperature 70°C.
Manual diverter headwork with a chromium plated brass body and NBR ‘O’ rings. Maximum working pressure 10.0 bar. Maximum operating temperature 85°C
Range of ceramic cartridge, ceramic disc, non-rising spindle, or push button cartridge (see models) headworks to be installed in specifically dimensioned bodies. Maximum working pressure 25.0 bar. Maximum operating temperature 65°C.
Range of ceramic cartridge headworks with NBR ‘O’-rings and silicone seals or silicone ‘O’-rings and seals (depending on model). For insertion into specifically dimensioned tap assemblies. Maximum working pressure 10.0 bar. Models 35H-F, 40D-F & 40H-F have a maximum operating temperature of 60°C. All other models have a maximum operating temperature of 85°C.
Range of ceramic cartridge headworks with plastic bodies incorporating silicone seals for insertion into specifically dimensioned bodies. Maximum working pressure 10.0 bar. Maximum operating temperature 65°C
Ceramic cartridge headwork with plastic body and silicone seals, for insertion into specifically dimensioned tap assemblies. Maximum working pressure 10.0 bar. Maximum operating temperature 85°C.
Range of quarter turn and half turn ceramic disc headworks with brass bodies and silicone rubber gaskets for insertion into specifically dimensioned assemblies. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.
Range of CA43 thermostatic cartridges incorporating plastic bodies and stainless steel filters. For insertion into specifically dimensioned bodies. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.
Single hole, single outlet (swivel) combination tap assemblies (chromium plated brass). Incorporating ceramic cartridge headworks and single lever operating member. The flexible spout outlet incorporates a plastic aerator and an approved check valve cartridge, however, the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.
Range of single hole, single outlet fixed combination tap assemblies (chromium plated brass), incorporating a ceramic cartridge headwork with a single lever operating members. The spout outlet incorporates a plastic flow straightener. Products are supplied with a click type waste. Maximum operating pressure 5.0 bar. Maximum operating temperature 60°C
Range of single hole, single outlet (fixed) combination tap assemblies (chromium plated brass), incorporating a ceramic cartridge headwork with a single lever operating member. The spout outlets incorporate a plastic aerator. Products are supplied with a click type waste. Maximum working pressure 5.0 bar. Maximum operating temperature 70°C.
Range of single hole, single outlet (fixed) combination tap assemblies with brass bodies (chrome plated), incorporating a ceramic cartridge headwork with a single lever operating member. The spout outlets of models SAVV2313 & SEV313 incorporate a plastic aerator, model SPA2113/EX incorporates a stainless steel filter. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.
Single hole, single outlet (fixed) electronically controlled tap assemblies (chromium plated brass). Flow is controlled by a solenoid valve activated via infra-red sensor. Solenoid housing incorporated a filter mesh. The product is supplied with a stainless steel braided EPDM lined flexible hose assembly to connect between the tap body and the solenoid valve. The spout outlets incorporate a plastic aerator. Maximum working pressure 5.0 Bar. Maximum operating temperature 60°C.
Range of single hole, single outlet (fixed) combination tap assemblies (brass bodies - various finishes), incorporating a ceramic cartridge headwork with a single lever (Absolute range) or dome type (Engineer & Illustrious range) operating member. The spout outlet incorporates a plastic aerator. Maximum working pressure 3.0 bar. Maximum operating temperature 60.0°C
Range of single hole, single outlet (fixed) combination tap assemblies (chromium plated brass) incorporating a ceramic cartridge headwork with single lever operating member. The spout outlets incorporate a plastic aerator and the inlets incorporate a stainless steel strainer. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.
Range of single hole, single outlet (fixed) combination tap assemblies (chromium plated brass), incorporating a ceramic cartridge headwork with a single lever operating member. The spout outlet incorporates a plastic flow straightener with an optional aerator. Fittings are supplied with a pop-up waste. Maximum working pressure 5.0 Bar. Maximum operating temperature 60°C.
Single hole, single outlet fixed combination tap assembly (chromium plated brass), incorporating a ceramic cartridge headwork with a single lever operating member. The spout outlet incorporates a plastic flow straightener and the product is supplied with a click type waste. Maximum operating pressure 5.0 bar. Maximum operating temperature 60°C
Range of single hole, single outlet (fixed) combination tap assemblies (chromium plated brass) incorporating a ceramic cartridge headwork with a single lever operating member. The spout outlet of model 825JK incorporates a plastic aerator. Products are supplied with a click type waste. Maximum operating pressure 5.0 bar. Maximum operating temperature 60°C
Range of single hole, single outlet (fixed) combination tap assemblies with brass bodies (various finishes) incorporating a ceramic cartridge headwork with single lever operating members. The spout outlets incorporate a plastic aerator. Product is supplied with a pop-up waste. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.
Range of single hole, single outlet (swivel) combination tap assemblies (chromium plated brass). Incorporating ceramic cartridge headworks and single lever operating members. The spout outlet incorporates a plastic aerator. Maximum working pressure 6.0 bar. Maximum operating temperature 60°C.
Range of single hole, single outlet (swivel) combination tap assemblies with brass bodies (various finishes, see model). Incorporating ceramic cartridge headworks and various operating members. The spout outlet incorporates a plastic aerator. Product is supplied with a click type waste. Maximum working pressure 3.5 bar. Maximum operating temperature 60°C.
Single hole, single outlet (swivel) combination tap assembly (chromium plated brass), incorporating 3x quarter turn ceramic disc headworks with single lever operating members. The third ceramic disc headwork on the front of the tap body is intended to control the flow for a filtered water supply. The inlet to the cold supply incorporates an approved check valve cartridge, however the complete product has not been fully tested to demonstrate it provides backflow protection. The spout outlets incorporate a plastic Aerator. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.
Range of single hole, single outlet (swivel) combination tap assemblies with brass bodies (various finishes), incorporating a ceramic disc headwork and single lever operating member. The outlet incorporates a plastic aerator. Maximum working pressure 10.0 bar. Maximum operating temperature 70°C.
Single hole, single outlet (swivel) combination tap assembly (chromium plated brass), incorporating quarter turn ceramic disc headwork with single lever operating members. The spout outlet incorporates a plastic flow straightener. Maximum working pressure 10.0 bar. Maximum working temperature 60°C.
Range of single hole, single outlet (swivel) combination tap assemblies with brass bodies (chromium plated), incorporating ceramic cartridge headworks and single lever operating member. The connection to flexible hose and spray outlets incorporates an approved single check valve cartridge (however, the whole product has not been fully tested to demonstrate that it provides adequate backflow protection) the outlets incorporates a plastic aerator. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.
Range of single hole, single outlet (swivel) combination tap assemblies with brass bodies (various finishes), incorporating either a ceramic cartridge headwork (models SH2CP/SH2BN), or quarter turn ceramic disc headwork (all other models) and single lever operating members. The spout outlets of all models incorporate a plastic aerator. Maximum working pressure 8.0 bar. Maximum operating temperature 60°C.
Range of single hole, single outlet (swivel) combination tap assemblies (chromium plated brass) incorporating a ceramic cartridge headwork with a single lever operating member. The spout outlets incorporates a plastic flow straightner. Maximum working pressure 10.0 bar. Maximum operating temperature 85°C.
Single hole, single outlet (swivel) combination tap assembly (chromium plated stainless steel) incorporating quarter turn ceramic disc headworks and single lever operating members. The spout outlet incorporates a plastic aerator. Maximum working pressure 8.0 bar. Maximum operating temperature 60°C.
Range of single hole, single outlet (swivel) combination tap assemblies with brass bodies (various finishes), incorporating ceramic cartridge headworks and single lever operating members. The spout outlets incorporate a plastic aerator. Maximum working pressure 8.0 bar. Maximum operating temperature 60°C.
Two hole, single outlet (fixed) combination tap assembly (chromium plated brass) incorporating quarter turn ceramic disc headwork with single lever operating members. The spout outlet incorporates a plastic flow straightener & stainless-steel strainer. The product is supplied with metal backnuts. Maximum working pressure 10.0 bar. Maximum operating temperature 70°C.
Range two hole, single outlet (fixed) combination tap assembly (chromium plated brass), incorporating quarter turn ceramic disk headworks with single lever operating member. The spout outlet incorporates a plastic flow straightener. The product is supplied with plastic (model VSN208) metal (model DAR108) backnuts. Maximum working pressure 6.0 bar. Maximum operating temperature 60°C.
Range of wall mounted, two-hole, single outlet (fixed) combination tap assemblies with brass bodies (various finishes), incorporating ceramic cartridge headworks, and single lever operating members. The spout outlet incorporates a plastic aerator. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.
Two-hole, single outlet (fixed) combination tap assemblies (chromium plated brass & matt black finish) incorporating a quarter turn ceramic disc headworks with single lever operating members and a manually operated diverter to shower outlet. The spout outlets incorporate a plastic flow straightener and the products are supplied with a shower hose, shower handset and metal backnuts. Maximum working pressure 10.0 bar. Maximum operating temperature 70°C.
Range of two-hole, single outlet (fixed) combination tap assemblies (chromium plated brass), incorporating three quarter turn ceramic disc headworks controlling the flow and temperature with cross top operating members and a manually operated diverter to shower outlet with cross top operating members. Model T2DB is supplied with a shower handset and hose and model B2TDS is supplied with a shower pipe and arm. The spout outlets incorporate a plastic aerator or flow straightener. Products are supplied with metal backnuts. The inlets incorporate an approved check valve cartridge however, the complete products have not been fully tested to demonstrate it provides backflow protection Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.
Wall mounted, two-hole, single outlet (fixed) combination tap assembly (chromium plated brass) incorporating quarter turn ceramic disc headworks controlling the temperature with cross top operating members and a manually operated diverter to shower outlet controlling the flow with cross top operating members. The product is supplied with a shower pipe and arm. The spout outlets incorporate a plastic aerator or flow straightener. The inlets incorporate an approved check valve cartridge, however, the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.
Two hole, single outlet (fixed) combination tap assembly brass body(in various finishes), incorporating quarter turn ceramic disc headwork with single lever operating members and a self-cancelling diverter to shower outlet. The inlet to the shower handset incorporates an approved check valve cartridge, however, the complete product has not been fully tested to demonstrate it provides backflow protection. The spout outlet incorporates a plastic flow straightener and the product is supplied with a shower hose, shower handset and plastic backnuts. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.
Deck mounted, two-hole, single outlet (fixed) combination tap assembly (chromium plated brass) incorporating quarter turn ceramic disc headworks with single lever operating members and a self-cancelling diverter to the shower outlet. The spout outlet incorporates a plastic flow straightener or an optional aerator. The product is supplied with a shower hose, shower handset and metal backnuts. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.
Range of deck mounted, two-hole, single outlet (fixed), combination tap assemblies (chromium plated brass). The flow is controlled by quarter turn ceramic disc headwork, with dome operating members, which also diverts the flow between multiple shower outlets. The temperature is controlled by a thermostatic cartridge with dome type operating members and manual override button. The products incorporate a lockable diverter to shower outlet and the spout outlets incorporate a plastic flow straightener. Both inlets incorporate stainless steel strainers and approved check valve cartridges, however, the complete products have not been fully tested to demonstrate that they provide backflow protection. Model TLVBSM is supplied with a shower hose and shower handset. Model TLVBSM2B is supplied with a shower hose, shower handset, riser rail and soap dish. Both models are supplied with metal back nuts. Maximum working pressure 5.0 Bar. Maximum operating temperature 60°C.
Range of deck mounted two hole, double outlet (swivel) combination tap assemblies with brass bodies (various finishes), incorporating quarter turn ceramic disc (DLV305B, DLT305B) or rising spindle (CR305 “Bridge”, CR305/501 “Bridge” & GEO305) headworks. Models GEO305, DLT305B and DLV305B incorporate single lever type operating members. Models CR305 and CR305/501 incorporate cross top operating members. The products are supplied with plastic back nuts. Maximum operating pressure 10.0 bar. Maximum operating temperature 65°C.
Wall mounted two hole, double outlet (swivel) combination tap assembly (chromium plated brass) with quarter turn ceramic disc headworks and single lever type operating members. The product is supplied with plastic back nuts. Maximum operating pressure 10.0 bar. Maximum operating temperature 65°C.
Range of two hole, double outlet (swivel) combination tap assemblies (chromium plated brass). Incorporating quarter turn ceramic disc headworks and single lever (T-695-H1 & T-695-H2) or non-rising spindle headworks and cross top or dome type operating members (T-695M-H1, T-695M-H2, T-695M-H3, T-695M-H4 & T-695M-H5). The spout outlet incorporates a plastic flow straightener. Supplied with metal backnuts. Maximum working pressure 10.0 bar. Maximum operating temperature 85°C
Two hole, wall mounted, double outlet (swivel) combination tap assembly (chromium plated brass). Incorporating rising spindle headworks on the tap body controlling the supply to the pull out hand held pre rinse outlet. An additional rising spindle headwork with a cross top operating member controls the flow to the spout outlet. Maximum working pressure 8.6 bar. Maximum operating temperature 85°C.
Three-hole, single outlet, fixed combination tap assembly with a brass body (various finishes), incorporating quarter turn ceramic disc headwork with single lever operating members. The spout outlets incorporate a plastic aerator and the products are supplied with lever type pop-up waste and metal backnuts. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.
Range of three-hole, concealed, metal, single outlet (fixed) combination tap assemblies (chromium plated brass) incorporating quarter turn ceramic disc headwork with wheel, dome, cross top or single lever operating members. The spout outlet comes in various lengths and incorporates a plastic aerator. Maximum working pressure 3.0 bar. Maximum operating temperature 60°C.
Range of three hole, deck mounted, single outlet (fixed) combination tap assemblies (various finishes, see model) incorporating quarter turn ceramic disc headwork with either cross top or single lever operating members and interconnecting flexible hoses. The spout outlets incorporate a plastic aerator. Products are supplied with a pop-up waste. Maximum working pressure 4.1 bar. Maximum operating temperature 60°C.
Range of wall mounted three hole, single outlet (fixed) combination tap assemblies with brass bodies (various finishes) incorporating quarter turn ceramic disc headworks and single lever operating members. The spout outlets incorporate a plastic aerator. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.
Range of three hole, single outlet (fixed) combination tap assemblies with brass bodies (various finishes). Incorporating quarter turn ceramic disc headworks and single lever operating members and interconnecting flexible hoses. The spout outlets incorporate a plastic aerator. Maximum working pressure 10.0 Bar. Maximum operating temperature 60°C.
Two hole, single outlet (swivel) combination tap assembly (chromium plated brass), incorporating non-rising spindle headwork with cross top operating members and manually operated diverter to shower outlet. The spout outlet incorporates a plastic flow straightener (optional aerator is also supplied) and the product is supplied with a shower hose, shower handset and metal backnuts. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.
Range of five hole, single outlet (swivel) combination tap assemblies (chromium plated brass). Incorporating a ceramic cartridge headwork controlling the flow to the shower handset and two quarter turn ceramic disc headworks controlling the flow to the spout outlet, all with single lever operating members. The spout outlets incorporate a plastic aerator. The inlet to the shower handsets incorporate an approved check valve cartridge, however, the complete product has not been fully tested to demonstrate it provides backflow protection. The product is supplied with a shower hose and handset. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.
Wall mounted fixed spout outlet (chromium plated brass) with a plastic aerator. Maximum operating temperature 60°C
Wall mounted bath spout outlet with a brass body (chrome plated) and a plastic aerator. The spout outlet are supplied with a single lever type operating member. Maximum operating temperature 60°C.
Wall mounted bath spout outlet incorporating a brass body (chromium plated) and a plastic aerator. The product is supplied with a single lever type operating member. Maximum operating temperature 60°C.
Range of cylindrical expansion vessels incorporating butyl rubber diaphragms. The products are supplied with an Airfix TD T piece. Maximum working pressure of model Airfix D 35 litre is 8.0 bar. All other models have a maximum working pressure of 10.0 bar. Maximum operating temperature 100°C.
Range of brass caplillary fittings for use with EN1057 copper tube. Maximum working pressure 10.0 bar. Maximum operating temperature 85°C.
Range of brass compression fittings for use with copper pipe to EN1057. Maximum working pressure 16.0 bar. Maximum operating temperature 100°C.
Range of Flomasta brass pushfit fittings for use with PE-x pipe (manufactured to BS7291-3), PB pipe (manufactured to BS7291-2) & copper pipe. Maximum working pressure 10.0 bar @ 65°C (PSU & DZR Brass Fittings). Open outlet use only @ 20°C (POM Fittings).
Range of end feed copper fittings for use with copper tube. Maximum working pressure 16.0 bar. Maximum operating temperature 95°C.
End Feed Range copper fittings for use with copper tube. For above and below ground use Maximum working pressure 20.0 bar. Maximum operating temperature 85°C.
Uponor Combi Port range of indirect heat interface units providing heating and instantaneous hot water. The heating system incorporates an expansion vessel and pressure relief valve (set at 3.0 bar).Some units have optional ball valve sets. Primary side heating 85°C and 2.5 bar. Secondary side, space heating 60°C and 2.5 bar. Secondary side DHW 60°C and 4.0 bar.
Range of copper brazed, stainless steel heat exchangers in various sizes (4-300 plates, see model). Models size X8T-SC-S Maximum working pressure primary circuit: 32.0 bar Maximum working pressure secondary circuit: 26.0 bar Maximum operating temperature: 99°C Models size 10T-SC-M Maximum working pressure primary circuit: 41.0 bar Maximum working pressure secondary circuit: 36.0 bar Maximum operating temperature: 99°C Models size 15T-SC-M Maximum working pressure primary circuit: 45.0 bar Maximum working pressure secondary circuit: 45 bar Maximum operating temperature: 99°C Models size 16DW-SC-S Maximum working pressure primary circuit: 16.0 bar Maximum working pressure secondary circuit: 16.0 bar Maximum operating temperature: 99°C Models size 16DW-SC-M Maximum working pressure primary circuit: 45.0 bar Maximum working pressure secondary circuit: 45.0 bar Maximum operating temperature: 99°C Models size 220-SC-S Maximum working pressure primary circuit: 25.0 bar Maximum working pressure secondary circuit: 25.0 bars Maximum operating temperature: 99°C Models size 320HT-SC-S Maximum working pressure primary circuit: 33.0 bar Maximum working pressure secondary circuit: 29.0 bar Maximum operating temperature: 99°C Models size 320LT-SC-S Maximum working pressure primary circuit: 33.0 bars Maximum working pressure secondary circuit: 29.0 bars Maximum operating temperature: 99°C
Range of wall mounted combination boilers providing domestic hot water via a plate heat exchanger and pressurised central heating system. Incorporating a pressure relief valve and expansion vessel. Primary circuit has a maximum working pressure of 3.5 bar and operating temperature of 85°C. Secondary circuit has a maximum working pressure of 10.0 bar and operating temperature of 60°C.
Assembly of pipe and fittings for use Arjo Huntleigh assisted bathing units. The assemblies comprise of either brass compression fittings or plastic push fit fittings for use with Uponor WIrsbo PEX pipe. The inlet of the 22mm assembly incorporates a combined spherical valve and strainer with brass body and stainless-steel filter. The strainer incorporates an approved check valve cartridge however, the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum working pressure 6.0 bar. Maximum operating temperature for assemblies incorporating brass compression fittings is 80°C. Maximum operating temperature for assemblies incorporating PEX push fit fittings is 50°C.
Range of flow sensors incorporating either brass, plastic or stainless steel bodies & EPDM ‘O’-rings. Maximum working pressure 10.0 bar for models VVXA, VVXC, VVXB. Maximum working pressure 16.0 bar for models VVXD & VVXE. Maximum operating temperature 90°C.
Range of in-line plastic flow regulators. The flow regulator is housed within a black plastic body incorporating a plastic strainer and an EPDM ‘O’-ring. Maximum working pressure 10.0 bar. Maximum operating temperature 90°C.
Range of flow through valves with brass bodies and EPDM ‘O’-rings, incorporating a spherical valve and a separate drain tap. The products are intended for connection prior to an expansion vessel. Maximum working pressure 5.0 bar. Maximum operating temperature 85°C.
Range of water monitoring systems comprising of a battery or mains operated latching solenoid valve (plastic body) and a flow sensor. The units are supplied with a hand-held controller. Maximum working pressure 10.0 bar. Cold water use only.
Range of click type pop-up wastes with brass bodies and EPDM rubber seals. Product is supplied with plastic back nuts.
Range of flow measurement devices (DZR brass) bodies incorporating two test ports. Maximum working pressure 25.0 bar. Maximum operating temperature 85°C.
Range of screwed gland cock valves with bronze bodies, EPDM seats and ‘O’-rings. The products incorporate a hose union outlet connection. Maximum working pressure 10.0 bar. Maximum operating temperature 100°C.
Flow sensor with a plastic body. Maximum working pressure 10.0 bar. Maximum operating temperature 85°C.
Range of cold water supply booster sets, incorporating a stainless steel manifold system and between 1 and 4 pumps depending on model. The booster sets also incorporate spherical valves, non-return valves, pressure switches/sensors and expansion vessels. Maximum working pressure 10.0 bar or 16.0 bar, dictated by the pump model(s) fitted. Cold water use only.
Range of shower booster pumps (either single or double) with acetal bodies and impellers and EPDM seals and NBR `O`-rings. Supplied with stainless-steel braided EPDM lined flexible hoses incorporating isolation valves Maximum working pressure 3.0 bar. Maximum operating temperature 65°C.
Range of vertical submersible multistage pumps. Cold water use only. Open outlet use only.
Range of central heating pumps incorporating polyether sulphone impellers, copper-tin alloy body, carbon graphite axial bearings and EPDM O-rings. Maximum working pressure 16.0 bar. Maximum operating temperature 99°C.
Range of wall mounted shower kit with brass bodies (various finishes) consisting of a shower rail with an overhead shower rose, incorporating a manual diverter to shower handset. Shower handset incorporates an approved check valve cartridge, however, the complete product has not been fully tested to demonstrate it provides backflow protection. Models AOOSCPUK and AOOSBKUK consist of just a shower handset. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.
Range of shower handsets with chromium plated ABS bodies. Some models incorporate multi-spray patterns. Maximum operating temperature 60 °C.
Shower outlet kit comprising of a shower handset, hose and holder. The hose contains an approved check valve cartridge, however, the complete product have not been fully tested to demonstrate it provides backflow protection. Maximum operating temperature 60°C.
Range of shower outlets with brass bodies (various finishes) and NBR ‘O’ rings. The inlets incorporate a flow regulator. Maximum operating temperature 60°C. Open outlet use only.
Range of shower heads incorporating chrome plated plastic bodies and stainless-steel strainers at the inlets. Maximum operating temperature 70°C
Range of wall mounted shower outlets (chromium plated brass). Models ARMW02 and ARMW05 are supplied with metal backnuts. Maximum operating pressure 10.0 bar. Maximum operating temperature 65°C.
Range of overhead shower outlets with ABS bodies (chrome finish) and EPDM washers. Maximum operating temperature 70°C.
Range of shower handsets with a chromium plated plastic body. The inlets incorporate a flow regulator. Maximum operating temperature 60°C.
Ceiling mounted shower outlet consisting of a (chrome plated) brass shower arm and a (chrome plated) stainless steel shower rose with an integral ball joint and silicone nozzles . The connection between the shower arm and the ball joint incorporates a combined EPDM washer and stainless steel strainer. The connection between the ball joint and the overhead shower incorporates a plastic flow regulator. Maximum operating temperature 60°C.
Range of overhead shower outlets with brass bodies (various finishes), with a ball joint, EPDM ‘O’-rings and a NBR seal. The inlet incorporates a plastic flow regulator. Maximum operating temperature 60°C.
Range of Grohe Euphoria 110’ hand showers with chromium plated plastic bodies. The inlet of model 27.221 incoporates a plastic flow regulator. Maximum operating temperature 60°C.
Range of in-line `Y`-patterned strainers with bronze bodies incorporating stainless steel mesh strainers and PTFE washers. Maximum working pressure 20.0 bar. Maximum operating temperature 85°C.
Range of in-line `Y`-patterned strainers with bronze bodies incorporating stainless steel mesh strainers and PTFE washers. Maximum working pressure 20.0 bar. Maximum operating temperature 85°C.
Range of Y-patterned strainers incorporating ductile iron, blue epoxy coated bodies and stainless steel screen. Maximum working pressure 16.0 bar. Maximum operating temperature 85°C
43250-TASTR Range of in-line `Y` pattern strainers incorporating DZR brass bodies, stainless steel mesh strainers and white PTFE gaskets. Maximum working pressure 25.0 bar. Maximum operating temperature 85°C.
Range of Y-patterned strainers incorporating ductile iron, blue epoxy coated bodies and stainless steel screen. Maximum working pressure 16.0 bar. Maximum operating temperature 85°C
Boss range of 46W & 46CW Y-pattern strainers with DZR brass bodies and stainless steel strainers. Maximum working pressure 20 bar (BSP threaded models ½”-2”), 16.0 bar (BSP threaded models 2½”-3” and compression models). Maximum operating temperature 85°C.
Range of drain off taps incorporating DZR brass bodies, non-rising spindle operating mechanism and EPDM ‘O’-rings and seat washer. D340 range incorporates a lockshield mechanism and the D341 range incorporates a key operated mechanism. Maximum working pressure 16.0 bar. Maximum operating temperature 85°C.
Range of wall or floor mounted, self-closing taps (chromium plated brass) with spring loaded headworks and either dome type, foot pedal or stick operating members. The outlet of model 9003S incorporates a plastic flow straightener. Maximum working pressure 5.0 bar. Maximum operating temperature 60⁰C.
Range of wall mounted non concussive shower valves with either a concealed or exposed brass body and chrome plated trim. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.
Range of PET (Polyethylene terephthalate) braided flexible hoses incorporating HDPE liner and EPDM ‘O’-rings. Maximum working pressure 5.0 bar. Maximum operating temperature 85°C Models added in January 2022: Maximum operating temperature 70°C.
Range of PVC lined shower hoses incorporating either a multilayer construction or interlocked outer. Maximum operating temperature 60°C.
Range of automatic air venting valves with a brass body and a plastic float. Maximum working pressure 10.0 bar. Maximum operating temperature 115°C.
Range of manually operated, wall mounted, concealed blending valves (chromium plated brass), incorporating a ceramic cartridge headwork, controlling both flow and temperature, with a single lever operating member. All models incorporate integrated shower connections and hoses. Model 36111970 is supplied with a mounting bracket. The inlets of all models incorporate an approved check valve cartridge however, the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.
Range of wall mounted thermostatic blending valves with chrome plated brass bodies and ceramic disc headwork with a dome type operating member. Temperature is controlled independently via a thermostatis cartridge also with a dome type operating member. Inlets incorporate single check valve cartridges however, the complete assembly has not been tested to demonstrate it provides adequate backflow protection. Supplied with a shower, hose, handset and rail. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.
Wall mounted exposed bar type thermostatic blending valve (chromium plated brass) with a half turn ceramic disc headwork controlling the flow and a thermostatic cartridge controlling the temperature, both with cubed type operating members incorporating manual override buttons. Each inlet incorporates a stainless-steel strainer and an approved check valve cartridge however, the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum working pressure 5.0 bar. Maximum operating temperature 60.0°C
Shower kit consisting of a wall mounted thermostatic blending valve incorporating a brass body (chrome plated), quarter turn ceramic disc headwork controlling the flow, the temperature is controlled via a thermostatic cartridge which incorporates a manual override button and dome type operating members. Each inlet incorporates a combined EPDM washer with stainless steel strainer and an approved check valve cartridge, however, the complete product has not been fully tested to demonstrate it provides backflow protection. The product is supplied with shower hose, shower handset, riser rail. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.
Range of wall mounted bar type thermostatic shower mixers (chromium plated brass) incorporating a ceramic disc headworks controlling the flow, temperature is controlled via a thermostatic cartridge with dome type or cube type (model WCTS). All operating members incorporate a manual override button. Inlets incorporate approved single check valve cartridges (however, the complete assemblies have not been fully tested to demonstrate that they provide adequate backflow protection) and stainless steel strainers. All products are supplied with a shower hose, shower handset, riser rail & soap tray. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.
Range of adjustable T type thermostatic blending valves (DZR brass) with push-fit connections for use with copper, PE-X (BS7921 Part 3: 2010) and Polybutylene (NBS7921/2) pipe. Each inlet incorporates a stainless-steel strainer and an approved check valve cartridge however, the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum working pressure 10.0 bar. Maximum operating temperature 85°C.
Range wall mounted exposed or concealed thermostatic shower valves having brass bodies (chromium plated) or chrome plated trim sets when concealed. Flow and temperature are controlled via a thermostatic cartridge with a dome type operating member. Models supplied with a hose, shower rail and handset (Miniduo EV, Miniduo BIV, Miniduo BIR with Eco Showerhead) Maximum working pressure 5.0 bar. Maximum operating temperature 45°C.
Blending thermostatic valve incorporates a brass body and a thermostatic cartridge controlling the temperature. The inlets incorporate single check valve cartridge, however, the complete assembly has not been fully tested to demonstrate that it provides adequate backflow protection. Maximum working pressure 5.5 bar. Maximum operating temperature 60°C.
Range of wall mounted thermostatic blending valves (chromium plated brass) incorporating either a 2 way ceramic disc diverter (models T, SH103X) controlling the flow to either an overhead shower or shower handset with various operating members (See model) or a quarter turn ceramic disc headwork (models VM90, & VM93) with various operating members. The temperature is controlled independently via a thermostatic cartridge incorporating a manual override button. The inlets incorporate approved check valve cartridge(s), however, the complete product has not been fully tested to demonstrate it provides backflow protection and stainless steel strainers. Maximum working pressure 5.0 bar. Maximum operating temperature is 85°C.
Thermostatic blending valve with brass body (various finishes), incorporating two push cartridges to control the water to the 2 outlets independently. The temperature is controlled also controlled independently via a thermostatic cartridge with a dome operating member incorporating a manual override button. Both inlets incorporate an approved check valve cartridge, however, the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.
Range of concealed thermostatic shower blending valves (brass) incorporating quarter turn ceramic disc headworks controlling the flow with single lever/cross/dome operating members. Model 3551197090 has one headwork controlling the flow to a single outlet. Models 355249790 & 3552197090 have two headworks independently controlling the flow to two outlets. Model 3553497090 has three headworks independently controlling the flow to three outlets. The temperature is controlled independently via a thermostatic cartridge with a single lever operating member. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.
T-type thermostatic mixing valve with brass body, EPDM ‘O’-rings and stainless-steel strainers. The inlets incorporate stainless-steel strainers and an approved check valve cartridge verified by test (as suitable for backflow protection against Fluid Category 2). Maximum working pressure 10.0 bar. Maximum operating temperature 60°C
Range of thermostatic mixing valves incorporating brass bodies (chrome plated). The flow is controlled by quarter turn ceramic disc headwork, with dome or cube type operating members, which also diverts the flow between multiple shower outlets. The temperature is controlled by a thermostatic cartridge with dome or cube type operating members. Both inlets incorporate stainless steel strainers and approved check valve cartridges, however, the complete products have not been fully tested to demonstrate that they provide backflow protection. The products are supplied with a shower hose, shower handset and overhead shower outlet. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.
Range of two way and three way concealed thermostatic shower valves, incorporating brass bodies and ceramic disc headwork with dome type operating members which controls the flow and diverts to various shower outlets. Temperature is controlled by a thermostatic cartridge incorporating a manual over ride button. Inlets incorporate stainless steel filters and an approved single check valve cartridge (however the complete assembly has not been tested to demonstrate it provides adequate backflow protection). Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.
Range of concealed thermostatic mixing valves, incorporating quarter turn ceramic disc headworks, with dome type operating members, controlling the flow to multiple shower outlets. The temperature is controlled independently via a thermostatic cartridge with dome type operating member. The inlets incorporates stainless steel strainers an approved check valve cartridge however, the complete product has not been fully tested to demonstrate it provides backflow protection Maximum working pressure 5.0 bar. Maximum operating temperature 60°C
Range of wall mounted, bar type thermostatic shower valves (chromium plated brass), incorporating a ceramic disc headwork which controls and diverts the flow between two outlets (shower to shower) and off position with a cube type operating member (model C76086-05 ) or dome type operating member (model C26037-03). The temperature is controlled independently via a thermostatic cartridge with a cube type operating member incorporating a manual override button (model C76086-05 ) or dome type operating member incorporating a manual override button (model C26037-03). Both inlets incorporate stainless steel filters and a single check valve cartridge however the complete assembly has not been tested to demonstrate it provides adequate backflow protection. The valves are supplied with a shower hose, shower handset and fixed overhead shower rose. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.
Range of handwheel & gear operated butterfly valves with blue epoxy coated ductile iron bodies and discs and EPDM rubber seat. Maximum working pressure 16.0 bar. Cold water use only. Maximum operating temperature 85°C (from Sept 2021)
Range of lugged butterfly valves with blue epoxy coated ductile iron bodies and nickel plated ductile iron discs and an EPDM sealing ring. D71XLK models are lever operated, the D371XLK are handwheel operated. Maximum working pressure 16.0 bar. Maximum operating temperature 85°C.
Combined pressure and temperature relief valves with DZR brass bodies, stainless steel springs, nylon coated probe, EPDM diaphragm and silicone seat disc. The valves incorporate lever easing gear. The valves have a factory pre-set pressure of 7.0 or 10.0 bar (see model). Maximum operating temperature 85°C.
Range of combined pre-set temperature and pressure relief valves incorporating Bronze bodies, DZR brass seat and plunger, EPDM ‘O’-rings, PTFE seal and silicone diaphragm. The valves incorporate a manually operated lever easing gear. The valves are factory pre-set between 0.4 bar and 12.5 bar. Maximum operating temperature 90°C.
Combined temperature and pressure relief valve incorporating a gunmetal body and manually operated lever-type easing gear. Factory set at 7.0 bar. Maximum operating temperature 95°C.
2-way ceramic disc rotary diverter valve with a plastic body and silicon seals. For insertion into specifically dimensioned bodies. Maximum working pressure 10.0 bar. Maximum operating temperature 65°C.
Range of flow control valves incorporating quarter turn ceramic disc headworks housed within a brass bodies. Maximum working pressure 6.0 bar. Maximum operating temperature 60°C
Pre-set pressure relief valve (set @ 3.0 bar) incorporating a brass body, NBR ‘O’-ring and an EPDM diaphragm. The valve is fitted with a hand operated rotating easing gear. Maximum operating temperature 90°C.
Normally closed solenoid valve with a plastic body and EPDM diaphragm. Maximum working pressure 8.0 bar. Maximum operating temperature 85°C.
Range of spherical valves with lever operating member, stainless steel bodies, chromium plated stainless steel ball and PTFE seat. Maximum working pressure 66.0 bar. Maximum operating temperature 100°C.
Spherical valves incorporating bronze bodies with lever operating members, chromium plated brass ball and PTFE seat. Maximum working pressure 25.0 bar, Maximum operating temperature 85°C.
Spherical valves incorporating bronze bodies with lever operating members, chromium plated brass ball and PTFE seat. Maximum working pressure 25.0 bar, Maximum operating temperature 85°C.
Spherical valves incorporating bronze bodies with lever operating members, chromium plated brass ball and PTFE seat. Maximum working pressure 25.0 bar, Maximum operating temperature 85°C.
Spherical valve incorporating a DZR brass body, chromium plated brass ball & single lever operating member, with push-fit connections for use with copper, PE-X (class B1) and Polybutylene (class B1) pipe. Maximum working pressure 16.0 bar. Maximum operating temperature 85°C.
Range of spherical valves incorporating brushed chome plated brass bodies, ball and PTFE seats. Maximum working pressure 10.0 bar. Maximum operating temperature 95°C
Flomasta Range of brass bodied or chrome plated brass bodied spherical valves, with a brass ball and EPDM ‘O’-rings. All fittings are to be used with PE-x pipe (manufactured to BS7291-3), PB pipe (manufactured to BS7291-2) and copper pipe. Maximum working pressure 10.0 bar. Maximum operating temperature 65°C.
Range of lever operated spherical valves incorporating brass bodies and brass ball (various finishes) to be used with PEX pipe (manufactured to BS7291 part 3), Polybutylene Pipe (manufactured to BS7291 Part 2) and copper pipe (manufactured to EN1057). Maximum working pressure 6.0 bar (for PEX and Polybutylene pipe). Maximum working pressure of 20.0 bar (for copper pipe). Maximum operating temperature 95˚C.
Range of motorised spherical valves with stainless steel bodies, ball and PTFE seals Maximum working pressure 16.0 bar. Maximum operating temperature 99˚C.
Range of spherical valves with plastic bodies, EPDM ‘O’-rings and PTFE seats with compression end fittings. For use with MDPE pipe to EN12201. Maximum working pressure 10.0 bar. Cold water use only.
Flomasta Range of plastic bodied inline, tee and angled spherical valves with EPDM ‘O’-rings and either lever or screwdriver operated (see model). For use with copper and PE-x pipe (manufactured to BS7291-3). Maximum working pressure 10.0 bar. Maximum operating temperature 65°C.
Range of gate valves incorporating bronze bodies and wedges with PTFE seals. The valves are operated via a non-rising spindle with a hand wheel operating member. Maximum working pressure 20.0 bar. Maximum operating temperature 85°C.
Range of gate valves incorporating brass bodies and wedge with PTFE seals. The valves operate via a non-rising spindle headwork that incorporates a wheel type operating member. Maximum working pressure 20.0 Bar. Maximum operating temperature 85°C.
Range of gate valves incorporating bronze bodies and wedges with PTFE seals. The valves are operated via a non-rising spindle with a hand wheel operating member. Maximum working pressure 20.0 bar. Maximum operating temperature 85°C.
Range of gate valves with blue epoxy coated ductile iron bodies, EPDM coated ductile iron wedges. The valves operate via a non-rising spindle headwork with hand wheel operating member. Maximum working pressure 16.0 bar. Maximum operating temperature 85°C.
Range of hand wheel operated gate valves with bronze bodies, bronze wedges, non rising spindles and graphite gaskets. Maximum working pressure 25.0 bar. Maximum operating temperature 100°C.
Flomasta Range of inline screw down stop valves with plastic bodies, non-rising spindle headworks and dome type operating members for use with PE-x (manufactured to BS7291-3) and copper pipe. Maximum working pressure/temperature: 10.0 bar @ 20°C and 10.0 bar @ 65°C.
Range of bedpan washers with the flow controlled by a solenoid valve and discharged via a type `AB` airgap (verified by test - suitable for backflow protection against fluid category 5). Maximum working pressure 6.0 bar. Maximum operating temperature 60°C
Range of front-loading commercial washing machines with flow controlled by solenoid valve and discharged via a type `AB` airgap (verified by test - suitable for backflow protection against fluid category 5). The machines are supplied with double check valve assemblies (suitable for backflow protection against Fluid Category 3) Maximum working pressure 10.0 bar. Maximum operating temperature 60°C
Range of under-counter or counter-top drinking water dispensers delivering still ambient, still chilled & sparkling water. HygienePlus®. Models incorporate a built-in filter system. The flow is controlled by a solenoid valve which is either operated by a touch or a touch pad. The water is dispensed via a tap arrangement on under-counter versions or an integrated outlet on counter-top versions. The inlets incorporate an approved check valve cartridge assembly however, the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum working pressure 6.0 bar. Cold water use only.
Range of water fountains and bottle fillers, water fountains which can be chilled or ambient outlet temperatures, incorporating a solenoid controlling the flow which is activated via either a push button or IR activated sensor. Split level models incorporate both bottle filler and fountain outlets. Maximum working pressure 7.0 bar. Cold water use only.
'A8401700'. White coloured, compression moulded Ceramic Alumina Al960 sealing ring. For use with water up to 85°C.
'YS-01 Powder Coating'. Factory applied, blue coloured epoxy powder coating. Apply as per manufacturer's instruction document 'HJ-Q-SOP-05' dated 2020-1-10. Cure for 10 minutes@200°C. For use with water up to 85°C. This material is only approved for the curing conditions that appear on the approval. If the cure conditions are varied from those specified on the approval then the material is not covered by the scope of the approval.
'MS1545A Enamel Coating'. Factory applied, blue coloured enamel coating. Apply as per document reference 'WRAS-sample-0001' dated 29.10.2020. Cure for 19 minutes (14 minutes in burner zone) @860°C. For use with water up to 85°C. This material is only approved for the curing conditions that appear on the approval. If the cure conditions are varied from those specified on the approval then the material is not covered by the scope of the approval.
'XX-CM1'. Factory applied, grey coloured cement mortar. Mix and apply as per manufacturer's safety data sheet 'A1: 26-01-2020'. Cure for 5 hours@30°C and then steam cure for 6 hours@30°C. For use with water up to 65°C. This material is only approved for the curing conditions that appear on the approval. If the cure conditions are varied from those specified then the material is not covered by the scope of the approval.
'XX-CM2'. Factory applied, grey coloured cement mortar. Mix and apply as per manufacturer's safety data sheet 'A1: 26-01-2020'. Cure for 5 hours@30°C and then steam cure for 6 hours@30°C. For use with water up to 65°C. This material is only approved for the curing conditions that appear on the approval. If the cure conditions are varied from those specified then the material is not covered by the scope of the approval.
'XX-CM3'. Factory applied, grey coloured sulphate resistant cement mortar. Mix and apply as per manufacturer's safety data sheet 'A1: 26-01-2015'. Cure for 5 hours@30°C and then steam cure for 6 hours@30°C. For use with water up to 65°C. This material is only approved for the curing conditions that appear on the approval. If the cure conditions are varied from those specified then the material is not covered by the scope of the approval.
'Interline 925P Off White'. Site applied, two-component, white coloured (once mixed) epoxy coating comprising of Part A (white coloured, opaque paint) and Part B (brown coloured, translucent liquid). Mix Parts A and B in a 4.93:1 mass ratio. Cure for 7 days@30°C. For use with water up to 60°C. This material is only approved for the mixing and curing conditions that appear on the approval. If the mixing and/or curing conditions are varied from those specified on the approval then the material is not covered by the scope of the approval.
'H-451PW'. Factory applied epoxy resin coatings available in black, blue, grey & red colours. Mix and apply as per technical data sheet dated '12/12/2018'. Cure for 7 days@25°C. For use with water up to 23°C. This material is only approved for the curing conditions that appear on the approval. If the cure conditions are varied from those specified on the approval then the material is not covered by the scope of the approval.
'Jotapipe IL6001 50S'. Factory applied, blue coloured, fusion bonded epoxy coating. Apply as per technical data sheet dated '10 September 2019'. Cure for 15 minutes@230°C. For use with water up to 85°C. This material is only approved for the curing conditions that appear on the approval. If the cure conditions are varied from those specified on the approval then the material is not covered by the scope of the approval.
'PAKMEL EP#3500 Series'. Factory applied, grey coloured epoxy coating. Apply as per manufacturer's instructions dated 2020.11.27. Cure for 3 minutes@230°C. For use with water up to 23°C. This material is only approved for the curing conditions that appear on the approval. If the cure conditions are varied from those specified on the approval then the material is not covered by the scope of the approval.
'EDELPOXY FN 132 Blue'. Factory applied, blue coloured epoxy coating. Apply as per manufacturer's IFU reference 'PC 132' dated 'January 28, 2020'. Cure for 7 days@30°C. For use with water up to 85°C. This material is only approved for the curing conditions that appear on the approval. If the cure conditions are varied from those specified on the approval then the material is not covered by the scope of the approval.
'Interline 925P Light Grey'. Site applied applied, two-component, grey coloured (once mixed) epoxy coating comprising of Part A (grey coloured, opaque paint) and Part B (brown coloured, translucent liquid). Mix Parts A and B in a 4.93:1 mass ratio. Cure for 7 days@30°C. For use with water up to 60°C. This material is only approved for the mixing and curing conditions that appear on the approval. If the mixing and/or curing conditions are varied from those specified on the approval then the material is not covered by the scope of the approval.
'Interline 925 White with Ceilcote 680M Primer'. Site applied, white coloured (once mixed), two-component epoxy coating comprising of a two-component primer and two-component top-coat. The primer (Ceilcote 680M) comprises of Part A (uncoloured liquid) and Part B (uncoloured liquid). Mix Parts A and B in a 3:1 volume ratio. Cure for 10 days@30°C. The top-coat (Interline 925 White) comprises of Part A (white coloured, opaque paint) and Part B (white coloured, opaque paste). Mix Parts A and B in a 4.99:1 mass ratio. Cure for 7 days@30°C. For use with water up to 23°C. This material is only approved for the mixing and curing conditions that appear on the approval. If the mixing and/or curing conditions are varied from those specified on the approval then the material is not covered by the scope of the approval.
'MES Precast Tank Concrete Mix'. Factory made, grey coloured concrete & additive. Mix ingredients in the following percentages: Cement 19.10 %, Water 7.56 %, Coarse Aggregate 38.76 %, Fine Aggregate 34.46 %, Plastiment 186 0.03 % & ViscoCrete 0.12 %. Cure for 7 days@10°C. For use with water up to 23°C. This material is only approved for the mixing and curing conditions that appear on the approval. If the mixing and/or curing conditions are varied from those specified on the approval then the material is not covered by the scope of the approval.
'SF2800 & SF2400'. Green coloured, nitrile rubber/aramid material manufactured by calendering. For use with water up to 23°C. For use only as a jointing/gasket material having been tested at a reduced surface area to volume ratio.
'Novus 30'. Orange coloured, nitrile rubber/aramid fibre gasket material manufactured by calandering. For use with water up to 85°C. For use only as a jointing/gasket material having been tested at reduced surface area to volume ratio.
'Sealtex ST-2052'. Green coloured NBR/fibre material manufactured by calendering. For use with water up to 85°C. For use only as a jointing/gasket material having been tested at reduced surface area to volume ratio.
'Extrastrong Ivory Coloured (RAL 1015) Tank Panel'. Cream coloured, hot press moulded GRP panel. For use with water up to 50°C.
'GRP-FPI-KSA Fiberstrong'. Pale green coloured (opaque) GRP pipe manufactured by filament winding. Between September 2020 and April 2024 the pipe was for use with water up to 50°C. From May 2024, the pipe is for use with water up to 60°C.
'Aldex C700 & C700F'. Dark brown coloured ion exchange resins. For use with water up to 23°C.
'Aldex C800 Na (16-50 US mesh resin), Aldex C800x10 Na (16-50 US mesh resin), Aldex C800F (Na) (30-70 US mesh resin) & Aldex C800F (K) (30-70 US mesh resin)'. Ion exchange resins which are black coloured except C800F (Na) which is brown coloured. For use with water up to 23°C.
'RADILON® DT RV300RKC2 106 NT to RADILON® DT RV500RKC2 106 NT and RADILON® DT RV300RKC2 306 BK to RADILON® DT RV500RKC2 306 BK'. Natural (appears off-white in colour) or black, injection moulded glass fibre filled PA6.12 materials. For use with water up to 85°C.
‘TECHNYL ® SAFE D 219WFC V30 BK’ & ‘TECHNYL ® SAFE D 219WFC V50 BK’. Black coloured, injection moulded, glass fibre reinforced polyamide 6.10 materials. For use with water up to 85°C.
'Taromid A 260 HW GS10 Black & Taromid A 260 HW GS10 Blue'. Black or blue coloured, injection moulded PA66 materials. For use with water up to 23°C.
'POLYPOL-1005'. Light orange coloured, contact moulded unsaturated polyester resin material. For use with water up to 50°C.
'PolyPol-1023'. Yellow coloured, contact moulded, isophthalic, unsaturated polyester resin material. For use with water up to 23°C.
'Elofit'. Black coloured, injection moulded, PE100 electrofusion & spigot fittings. For use with water up to 85°C.
'SOFTPEX V® hose inliner'. Off white coloured (translucent), extruded polyethylene hose. For use with water up to 70°C.
'Parixit HDPE Pipe'. Blue coloured, extruded HDPE pipe. For use with water up to 60°C.
'Parixit HDPE Fitting'. Blue coloured, injection moulded HDPE fitting. For use with water up to 60°C.
'Kuzeyboru HDPE 100 Pipe'. Black coloured, extruded HDPE pipe. For use with water up to 23°C.
'Revolve 4068/N-250 (white coloured), M-586 (black coloured), M-638 (black coloured), M-694 (black coloured) & M-695 (black coloured)'. Polyethylene materials manufactured using rotational moulding. For use with water up to 85°C.
'SAB A16 Compression Fittings'. Black coloured, compression fitting bodies, injection moulded from polypropylene (PP-B). For use with water up to 60°C.
`Maxxam PP Flow Meter Insert`. Off-white coloured, injection moulded polypropylene flow meter insert. For use with water up to 23°C. From September 2023, the component is for use with water up to 85°C.
'Supreme S16 Compression Fittings'. Black coloured, compression fitting bodies, injection moulded from polypropylene (PP-B). For use with water up to 60°C.
'Moplen EP 300 K PP Cover'. White coloured, translucent, injection moulded polypropylene cover. For use with water up to 85°C.
'GLOBAL PP01'. Blue coloured, injection moulded PP fittings. For use with water up to 23°C.
'Buffalo VYLSF 410'. Grey coloured, two-component chemical anchor resin. Mix in a 10:1 volume ratio. Apply as per Buffalo Product Data Sheet. Cure for 7 days@7°C. For use with water up to 23°C. For use only as a resin anchor having been tested at a reduced surface area to volume ratio of 1,000mm² per 1 litre of water. This material is only approved for the mixing and curing conditions that appear on the approval. If the mix and cure conditions are varied from those specified on the approval then the material is not covered by the scope of the approval.
EP80/2 BLK 'O' rings & gaskets. Black coloured, injection moulded EPDM 'O' rings & gaskets. Shore hardness 80. Tested in-radius size 1.5mm. . For use with water up to 85°C.
'09-557'. Black coloured, compression moulded EPDM 'strip'. Shore hardness 80. Tested in-radius size 2.0mm. For use with water up to 85°C.
‘EP4118F, EP4518F, EP5118F, EP5518F, EP6118F, EP6518F, EP6512F (also known as EP6512P), E7008F, EP7118F, EP7518F, EP8018F, EP8118F, EP8518F & EP9118F’. Range of black coloured, compression moulded, EPDM ‘O’ rings and gaskets. Shore hardness between 40 & 90. ‘O’ rings with tested in-radii sizes of between 0.25mm & 5.00mm. Gaskets with tested in-radii sizes of between 0.25mm & 7.50mm. For use with water up to 85°C.
'EP5700'. Black coloured, compression moulded EPDM material. Shore hardness 57. Tested in-radius size 0.98mm. For use with water up to 23°C.
'EP70B002'. Black coloured, compression moulded EPDM material. Shore hardness 70. Tested in-radius size 1.0mm. For use with water up to 85°C.
'DLYY E6202'. Black coloured, compression moulded EPDM material. Shore hardness 60. Tested in-radius size 1.0mm. For use with water up to 23°C.
'Loxeal UVAE 83-50 HT Fluo'. Green coloured anaerobic adhesive. For use with water up to 85°C. These products are to be applied and cured in strict accordance with the manufacturer's instructions.
'Weld-On 724'. Orange coloured solvent cement. Apply as per manufacturer's product data sheet. Cure for 10 minutes@23°C. For use with water up to 23°C. This material is only approved for the curing conditions that appear on the approval. If the cure conditions are varied from those specified on the approval then the material is not covered by the scope of the approval.
'Weld-On 919XG'. Uncoloured, transparent PVC solvent cement. Apply as per manufacturer's product data sheet '919XG-11-2020'. Cure for 30 minutes@4°C. For use with water up to 23°C. This material is only approved for the curing conditions that appear on the approval. If the cure conditions are varied from those specified on the approval then the material is not covered by the scope of the approval.
'Effast Premium Large Tite'. Uncoloured, transparent PVC solvent cement. Apply as per manufacturer's product specification '11-2020'. Cure for 30 minutes@4°C. For use with water up to 23°C. This material is only approved for the curing conditions that appear on the approval. If the cure conditions are varied from those specified on the approval then the material is not covered by the scope of the approval.
'Ixef DW/FC 1032 BK001 (black coloured) & Ixef DW/FC 1032 NT000 (natural, appears off-white coloured)'. Injection moulded PARA (polyarylamide) materials. For use with water up to 85°C.
'Hytrel® 6359FG & 4068FG'. Cream coloured, injection moulded, thermoplastic polyester elastomeric materials. For use with water up to 85°C.
`Aqua Clean Mera` range of bidets incorporating an electronically operated seat, flow is controlled by solenoid valve and discharges via a type `AB` airgap (verified by test - suitable for backflow protection against fluid category 5). Maximum working pressure 10.0 bar. Cold water supply only.
'EcoFITTOM Fittings'. Blue coloured PVC fittings which are manufactured by extrusion and molecular orientation. For use with water up to 60°C.
'TOM PVC-O Pipe'. Blue coloured PVC pipe which is manufactured by extrusion and molecular orientation. For use with water up to 60°C.
Single hole, single outlet (fixed) electronically controlled tap assemblies (chromium plated brass), flow is controlled by a solenoid valve activated via an infra-red sensor. The tap connects to the solenoid valve via a copper tail with a ½” BSP (F) captive nut and a fibre washer. The product is supplied with a combined TPE washer and stainless steel strainer to be installed on the inlet to the solenoid. The spout outlets incorporate a plastic flow straightener. Maximum working pressure 8.0 bar. Maximum operating temperature 60°C.
Single hole, single outlet (fixed) electronically controlled tap assemblies (chromium plated brass), flow is controlled by a solenoid valve activated via an infra-red sensor. The tap connects to the solenoid valve via a copper tail with a ½” BSP (F) captive nut and a fibre washer. The product is supplied with a combined TPE washer and stainless steel strainer to be installed on the inlet to the solenoid. The spout outlets incorporate a plastic flow straightener. Maximum working pressure 8.0 bar. Maximum operating temperature 60°C.
Range of single hole, single outlet (fixed) electronically operated, tap assemblies (chromium plated brass). Flow is controlled via solenoid valve and actuated by a touch sensor. The spout outlets incorporate a plastic aerator, supplied with stainless steel strainers. Maximum working pressure 8.0 bar. Maximum operating temperature 60°C.
Single hole, single outlet (fixed) combination tap assembly (stainless steel). The flow is controlled by a solenoid valve that is actuated via an infra-red sensor on the spout. The inlet to the solenoid valve incorporates a stainless steel strainer. The spout outlet incorporates a plastic aerator. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.
Range of side entry BS1212-4 (2016) delayed action or non-delayed action type float operated valves for WC flushing cisterns. The inlet incorporates an optional flow restrictor. Maximum working pressure 10.0 bar. Cold water use only.
Side entry BS1212-4 (2016) compact type float operated valve for WC flushing cisterns. The inlet incorporates a strainer. Maximum working pressure 10.0 bar. Cold water use only.
BS EN 14055: 2018 concealed WC cistern incorporating a side or bottom entry compact type float operated inlet valve providing a Type AG air gap with a pneumatic or cable operated drop valve capable of full flush volumes of up to 6 litres and reduced flush of up to 4 litres. The cistern is operated by a manual push button. Maximum working pressure 10.0 bar. Cold water use only.
BS EN 14055: 2018 concealed WC cistern incorporating a side entry compact type float operated inlet valve providing a type `AB` airgap (verified by test - suitable for backflow protection against fluid category 5) with a pneumatic or cable operated drop valve capable of full flush volumes of up to 6 litres and reduced flush of up to 4 litres. The cistern is operated by manual push button. Maximum working pressure 10.0 bar. Cold water use only.
Range of three hole, single outlet (fixed) combination tap assembly (chromium plated brass). Incorporating ceramic cartridge headworks, single lever operating members & manually operated diverter to shower outlet. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.
Rainwater top up cistern with flow controlled by solenoid valve and discharged via a type `AB` airgap (verified by test - suitable for backflow protection against fluid category 5). Product also incorporates a stop valve, a flow restrictor and a float valve on the inlet. Maximum working pressure 10.0 bar. Cold water use only.
Spring loaded resilient trim in-line check valve cartridge with plastic guide, stem and housing, stainless steel spring and EPDM ‘O’-rings. For insertion into specifically dimensioned bores. Maximum working pressure 16.0 bar. Maximum operating temperature 85°C.
Range of spring loaded, resilient trim, in-line check valve cartridgse, with plastic guides & jumper and NBR or EPDM seals within a plastic housing. For insertion in pipes and fittings with specifically sized bores. Maximum working pressure 16.0 bar. Models NV20/DN20-EPDM 31.0004.0 & NV20/DN20-pr 31.0071.0 have a maximum operating temperature of 60°C. Models NV20/DN20 31.4221.0 & NV20/DN20-HT 31.0011.0 have a maximum operating temperature of 85°C.
Range of spring loaded, resilient trim, in-line check valve cartridge, with plastic guides & jumper and NBR or EPDM seals within a plastic housing. For insertion in pipes and fittings with specifically sized bores. Maximum working pressure 16.0 bar. Model 31.4220.0. has a maximum operating temperature of 85°C. Model 31.0003.0 has a maximum operating temperature of 60°C.
Range of spring loaded, resilient trim, in-line check valve cartridges, with plastic guides & plunger and EPDM or Silicone seals within a plastic housing. For insertion in pipes and fittings with specifically sized bores. Maximum working pressure 16.0 bar. Maximum operating temperature 60°C
Range of non-verifiable double check valve assemblies consisting of two spring loaded resilient trim in-line check valve cartridges housed in a DZR brass body, compression models are nickle plated. A drain port is provided between the cartridges. Compression models are to be used with copper pipe to EN1057. Maximum working pressure 16.0 Bar. Maximum operating temperature for the D220W range 85°C. Maximum operating temperature of the D200CW range 60°C.
‘Parker 500’ assisted bathing unit. Flow is controlled via a thermostatic mixing valve, the inlet of which incorporates a stainless steel strainer and single check valve cartridge (suitable for backflow protection against Fluid Category 2) and feeds either a bath spout outlet or shower handset which incorporates a self-closing trigger. The inlet to the shower handset incorporates a plastic flow restrictor and a single check valve cartridge however, the complete product has not been fully tested to demonstrate it provides backflow protection. There is a combined spherical valve and strainer on the inlet to the bathing unit which incorporates a single check valve cartridge (suitable for backflow protection against Fluid Category 2). The ‘shepherds crook’ type shower outlet is protected via an AUK3 airgap arrangement. Maximum working pressure 6.0 bar. Maximum operating temperature 80°C
ANP range of pre insulated one piece contact moulded GRP cold water storage cisterns and covers. Supplied with a wholesome water kit, consisting of a screened vent, screened warning pipe and screened overflow pipe. Cold water use only.
One-piece (white) HDPE plastic storage cistern with lid. Maximum operating temperature 60°C.
Range of hot pressed moulded GRP sectional cold water storage cisterns. Larger cisterns are fitted with PVC roof supports and are supplied with stainless steel ladders, tie rods, braces and hatches. Cold water use only.
An aerator attachment for a mixer tap with a black plastic body and NBR O-rings. The outlet incorporates a stainless-steel strainer. This product incorporates swivel joint and a mechanism that alters the flow from jet to spray. Maximum working temperature 60°C.
Range of ceramic cartridge headworks with plastic bodies and silicone ‘O’-rings and gaskets for insertion into specifically dimensioned tap assemblies. Maximum working pressure 12.0 bar. Maximum operating temperature 85°C.
Range of non-rising spindle headworks incorporating brass bodies, NBR rubber `O`-rings and silicone rubber gaskets. Model CL1/2M-360T 360° incorporates a non -rising spindle headwork, model CL1/2K-180T-10 incorporate a half turn ceramic disc headwork and other models incorporate a quarter turn ceramic disc headwork. Maximum working pressure 10.0 bar. Maximum operating temperature 85°C.
Manually operated 2-way diverter valve headwork, with a plastic body and silicone seals. To be inserted into specifically dimensioned bodies. Maximum working pressure 10.0 bar. Maximum working temperature 85°C.
Manually operated 2-way diverter valve headwork, with a plastic body and silicone seals. To be inserted into specifically dimensioned bodies. Maximum working pressure 10.0 bar. Maximum working temperature 85°C.
Range of non-rising headworks incorporating brass bodies, NBR ‘O’-rings and EPDM gaskets. The products are intended for insertion into specifically dimensioned tap assemblies. Maximum working pressure 16.0 bar. Maximum operating temperature 85°C.
Single hole, single outlet (fixed) combination tap assemblies (chromium plated brass), incorporating a quarter turn ceramic disc headworks and single lever operating members, with a pull out spray retained within a holster. The spout outlet incorporates a plastic aerator. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.
Range of single hole, single outlet (fixed) combination tap assemblies (chromium plated brass). incorporating a ceramic cartridge and single lever operating member with a spring loaded, pull down trigger operated spray. The spout outlet incorporates a plastic aerator. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.
Single hole, single outlet (waterfall spout) combination tap assembly with brass body (various finishes), incorporating a ceramic cartridge headwork with single lever operating member. The inlets incorporate a stainless-steel strainer and the product is supplied with a pop-up waste. Maximum working pressure 10.0 bar. Maximum operating temperature 60ºC.
Range of single hole, single outlet (fixed) combination tap assemblies (chromium plated brass), incorporating ceramic cartridge headworks with single lever operating members. The spout outlets incorporate a plastic aerator. Products come with pop up wastes. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.
Range of single hole, single outlet (fixed) combination tap assemblies with brass bodies (various finishes), incorporating a ceramic cartridge headworks and single lever operating member. The spout outlets incorporate a plastic aerator. Some models are supplied with a pop-up waste. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.
Range of single hole, single outlet (fixed) combination tap assemblies (chromium plated brass) incorporating a ceramic cartridge headwork with a single lever operating member. The spout outlets incorporate either a plastic flow straightener or aerator. The product is supplied with a click type waste. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.
Range of single hole, single outlet (fixed) combination tap assemblies (chromium plated brass), incorporating a ceramic cartridge headwork with a single lever operating member. The spout outlet incorporates a plastic flow straightener with an optional aerator. Fittings are supplied with a pop-up waste. Maximum working pressure 5.0 Bar. Maximum operating temperature 60°C.
Range of single hole, single outlet (fixed) combination tap assemblies (chromium plated brass), incorporating a ceramic cartridge headwork with a single lever operating member. The spout outlet incorporates a plastic flow straightener with an optional aerator. Fittings are supplied with a pop-up waste. Maximum working pressure 5.0 Bar. Maximum operating temperature 60°C.
Range of single hole, single outlet (fixed) combination tap assemblies (various finishes, see model). Incorporating ceramic cartridge headworks, and single lever operating members. The inlets incorporate flow strainer and the spout outlet incorporates a plastic flow straightener. Can be supplied with our without a pop up waste. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.
Range of single hole, single outlet (fixed) combination tap assemblies (chromium plated brass), incorporating ceramic cartridge headworks and single lever operating members. The tap body incorporates plastic flow regulator and the product is also supplied with a click type pop-up waste. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.
Range of single hole, single outlet (fixed) combination tap assemblies (chromium plated brass), incorporating ceramic cartridge headworks, single lever operating members. The spout outlets incorporate a plastic aerator and the products are supplied with a pop up waste. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.
Range of single hole, single outlet (fixed) combination tap assemblies (chromium plated brass). Incorporating ceramic cartridge headworks, and single lever operating members. The spout outlets incorporate a plastic aerator and some models are supplied with a pop-up waste. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.
Range of single hole, single outlet (swivel) combination tap assemblies (chromium plated brass) incorporating a ceramic cartridge headwork with a single lever operating member. The spout outlets incorporates a plastic flow straightner. Maximum working pressure 10.0 bar. Maximum operating temperature 85°C.
Range of single hole, single outlet (swivel) combination tap assemblies (chromium plated brass), incorporating ceramic cartridge headworks and single lever operating members. The spout outlet incorporates a plastic aerator. The inlets incorporate an approved check valve cartridge, however, the complete product has not been fully tested to demonstrate it provides backflow protection Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.
Single hole, single outlet (swivel) comination tap assembly (chromium plated brass), incorporation a non-rising spindleheadwork with crosstop type operating members. The spout outlets incorporate a metal strainer and either a plastic aerator or alternative flow straightener. Maximum working pressure 10.0 bar. Maximum operating temperature 70°C.
Single hole, single outlet (swivel) comination tap assembly (chromium plated brass). Incorporation a ceramic disc headwork with dome type operating members. The spout outlets incorporate a metal strainer and either a plastic aerator or alternative flow straightener. Maximum working pressure 10.0 bar. Maximum operating temperature 70°C.
Single hole, single outlet (swivel) comination tap assembly (chromium plated brass), incorporation a ceramic disc headwork with lever type operating members.The spout outlets incorporate a metal strainer and either a plastic aerator or alternative flow straightener. Maximum working pressure 10.0 bar. Maximum operating temperature 70°C
Range of single hole, single outlet (swivel) combination tap assemblies (chromium plated brass), incorporating a ceramic cartridge headwork with a single lever operating member. The spout incorporates a plastic aerator, model BM1400 Blanco Crest incorporates a plastic flow straightener. Maximum operating pressure 5.0 bar. Maximum operating temperature 60˚C.
Range of single-hole, single outlet, (swivel) combination tap assemblies with brass bodies (various finishes), incorporating quarter turn ceramic cartridge headworks with single lever operating members. The spout outlets incorporate a plastic aerator and the inlets incorporate a stainless-steel strainer. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.
A range of single-hole, single outlet, (swivel) combination tap assemblies with brass bodies (chromium plated). Incorporating ceramic cartridge headworks with single lever operating members. The spout outlets incorporate a plastic aerator. Maximum working pressure 5.0 bar, Maximum working temperature 60 °C.
Range of single hole, single outlet, (swivel) combination tap assemblies with brass bodies (chromium plated), incorporating ceramic cartridge headworks and single lever operating members. The spout outlet incorporates a plastic aerator. The inlet hoses incorporate a combined stainless-steel strainer and silicone washer. Maximum working pressure 5.0 bar. Maximum working temperature 60°C.
Range of single hole, single outlet (swivel) combination tap assemblies with brass bodies (various finishes). Models SM056, SM056F, SM056/501, SM056/NI & SM056/BZ incorporate ceramic cartridge headworks with single lever operating members. Models SM057 & SM057/501 incorporate non-rising spindle headworks with cross top operating members. The spout outlet incorporates a plastic flow straightener. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.
Range of single hole, double outlet (swivel) combination tap assemblies (chromium plated brass). All models can be specified with either a non rising spindle headwork or a quarter turn ceramic disc headwork with dome (Tevere), cross top (Monaco) or single lever (Miura) operating members. The spout outlet incorporates a plastic flow straightener. Maximum working pressure 10.0 bar. Maximum operating temperature 65°C.
Range of wall mounted, concealed two-hole, single outlet (fixed) combination tap assemblies (brass bodies, various finishes) incorporating ceramic cartridge headwork with single lever operating members. The spout outlets incorporate a plastic aerator, some also incorporate a flow regulator. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C
Range two hole, single outlet (fixed) combination tap assembly (chromium plated brass), incorporating quarter turn ceramic disk headworks with single lever or cross top (model MOT108) operating members. The spout outlets incorporates a plastic flow straightener. The products are supplied with plastic backnuts. Maximum working pressure 6.0 bar. Maximum operating temperature 60°C.
Two-hole, singe outlet (fixed) combination tap assembly (chromium plated brass). Incorporating a quarter turn ceramic disc headworks with single lever type operating members. The outlet incorporates a plastic flow straightener. Product is also supplied with plastic back nuts. Maximum working pressure 10.0 bar. Maximum operating temperature 60ºC.
Range of deck mounted, two hole, single outlet (fixed) combination tap assemblies (various finishes), incorporating a non-rising spindle headwork with cross top operating members and a manual diverter to shower outlet. The product is supplied with a shower hose and handset. Maximum working pressure 10.0 bar. Maximum operating temperature 65°C.
Range of deck mounted, two hole, single outlet (fixed) combination tap assemblies (gold plated brass) incorporating a non-rising spindle headwork with cross top operating members and a manual diverter to shower outlet. The product is supplied with a shower hose and handset. Maximum working pressure 10.0 bar. Maximum operating temperature 65°C.
Two-hole, single outlet (fixed) combination tap assembly (chromium plated brass) incorporating a quarter turn ceramic disc headworks with single lever operating members and a manually operated diverter to shower outlet. The spout outlet incorporates a plastic flow straightener. The product is supplied with a shower hose, shower handset and metal backnuts. Maximum working pressure 10.0 bar. Maximum operating temperature 70°C.
Two-hole, single outlet (fixed) combination tap assembly with brass body (chromium plated). The flow is controlled via a quater turn ceramic disc headworks and single lever operating members and a manually operated diverter to shower outlet. Supplied with metal backnuts. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.
Two-hole, single outlet (fixed) combination tap assembly (chromium plated brass). The flow is controlled via non-rising spindle headworks with cross top operating members and a manually operated diverter to shower outlet. Supplied with hose and handset. The spout outlet incorporates a plastic flow straightener. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.
Range of two hole, single outlet (fixed) combination tap assemblies (chromium plated brass). Models M4305, M4305E incorporate a non-rising spindle headwork with dome type operating members. Models M4305G & M4305F incorporate a non-rising spindle headwork with cross top operating members. Model M33135 incorporate a quarter turn ceramic disc headwork with single lever operating members. The fitting incorporates a manual diverter to the shower outlet The spout outlet incorporates a plastic flow straightener and the products are supplied with a shower hose, shower handset and metal backnuts. Maximum working pressure 10.0 bar. Maximum operating temperature 70°C.
Two-hole, single outlet (fixed) combination tap assembly (chromium plated brass), incorporating quarter turn ceramic disc headwork with single lever operating members and a self-cancelling diverter to shower outlet. The spout outlet incorporates a plastic flow straightener. The product is supplied with a shower hose, shower handset and metal backnuts. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.
Two-hole, single outlet (fixed) combination tap assembly (chromium plated brass), incorporating quarter turn ceramic disc headwork with single lever operating members and a self-cancelling diverter to shower outlet. The spout outlet incorporates a plastic flow straightener and the product is supplied with a shower hose, shower handset and metal backnuts Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.
Two hole, single outlet (fixed) combination tap assembly (chromium plated brass), incorporating ceramic disc headworks with single lever operating members and a self-cancelling diverter to the shower outlet. The spout outlet incorporates a plastic flow straightener or optional aerator. The product is supplied with a shower hose, shower handset and metal backnuts. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.
Deck mounted, two-hole, single outlet (fixed) combination tap assembly (chromium plated brass) incorporating quarter turn ceramic disc headworks with single lever operating members and a self-cancelling diverter to the shower outlet. The spout outlet incorporates a plastic flow straightener or an optional aerator. The product is supplied with a shower hose, shower handset and metal backnuts. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.
Deck mounted, two-hole, single outlet (fixed) combination tap assembly (chromium plated brass) incorporating quarter turn ceramic disc headworks with single lever operating members and a self-cancelling diverter to the shower outlet. The spout outlet incorporates a plastic flow straightener or an optional aerator. The product is supplied with a shower hose, shower handset and metal backnuts. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.
Two-hole, single outlet (fixed) combination tap assembly (chromium plated brass), incorporating quarter turn ceramic disc headwork with single lever operating members and a self-cancelling diverter to shower outlet. The spout outlet incorporates a plastic flow straightener. The product is supplied with a shower hose, shower handset and metal backnuts. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.
Two-hole, single outlet, (fixed) combination tap assembly with brass body (various finishes), incorporating a ceramic cartridge headwork with single lever operating members and a self-cancelling diverter to shower outlet. The spout outlet incorporates a plastic aerator and the shower outlet incorporates an approved check valve cartridge, however, the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.
Two hole, single outlet (fixed) combination tap assembly (chromium plated brass) incorporating quarter turn ceramic disc headwork, single lever operating members and self- cancelling diverter to shower outlet. The spout outlet incorporates a plastic flow straightener & the products are supplied with metal backnuts. The product includes a shower hose and handset. Maximum working pressure 10.0 bar. Maximum working temperature 70°C.
Range of wall mounted, two-hole, single outlet (swivel) combination tap assemblies (chromium plated brass), incorporating ceramic cartridge headworks and single lever operating members. The spout outlet incorporates a plastic flow straightener. The inlet offset unions incorporate an isolation valve. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.
Range of two hole, double outlet (swivel) combination tap assemblies (chromium plated brass). All models can be specified with either a non rising spindle headwork or a quarter turn ceramic disc headwork with dome (Tevere), cross top (Monaco) or single lever (Miura) operating members. The spout outlet incorporates a plastic flow straightener. The product is supplied with metal backnuts. Maximum working pressure 10.0 bar. Maximum operating temperature 65°C.
Three hole, single outlet (fixed) combination tap assemblies (various finishes), incorporating quarter turn ceramic disc headworks with single lever operating members. The spout outlets incorporate a plastic aerator and is connected to the headworks via stainless steel braided PEX lined hose assemblies. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.
Three hole, single outlet (fixed) combination tap assemblies with a brass body (various finishes), incorporating quarter turn ceramic disc headworks with single lever operating members and a self-cancelling diverter to shower outlet. The spout outlet incorporates a plastic flow aerator. Maximum working pressure 10.0 Bar. Maximum operating temperature 60ºC.
Range of three hole, single outlet (swivel) combination tap assembly (chromium plated brass) incorporating quarter turn ceramic disc headwork with single lever operating members. The spout outlet incorporates a plastic aerator. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.
Four-hole, single outlet (fixed) combination tap assembly (chromium plated brass), incorporating a ceramic cartridge headwork with a single lever type operating member and a self-cancelling diverter to shower outlet. The spout outlet incorporates a plastic flow straightener. The product is supplied with a shower hose & handset. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.
Range of combined bath fillers and overflows with a plastic body and a variety of different trims. The outlet incorporates a plastic flow regulator and the products are supplied with a cable operated pop-up waste. Maximum operating temperature 65°C.
Page 1 of 12
We use cookies to give you the best possible experience with WRAS. Some are essential to provide website functions and ensure the website is secure. We also use cookies to help us understand how people use the site and to make improvements. Click "Accept All" to enable recommended settings or click "Manage cookies" to adjust your settings. For more details, see our Cookie Policy.