WC flushing cistern incorporating a side entry compact type float operated inlet valve providing a Type AG air gap with a dual flush drop valve for full flush volumes of up to 6 litres and a reduced flush of up to 4 litres. The cistern is operated by a manual push button and incorporates a servicing valve on the inlet supply. Maximum working pressure 10.0 bar. Cold water use only.
WC flushing cistern incorporating a side entry compact type float operated inlet valve providing a Type AG air gap with a dual flush drop valve for full flush volumes of up to 6 litres and a reduced flush of up to 4 litres. The cistern is operated by a manual push button and incorporates a servicing valve on the inlet supply. Maximum working pressure 10.0 bar. Cold water use only.
WC flushing cistern incorporating a side entry compact type float operated inlet valve providing a Type AG air gap with a dual flush drop valve for full flush volumes of up to 6 litres and a reduced flush of up to 4 litres. The cistern is operated by a manual push button and incorporates a servicing valve on the inlet supply. Maximum working pressure 10.0 bar. Cold water use only.
BS EN 14055: 2018 concealed WC cistern incorporating a side entry compact type float operated inlet valve providing a type `AB` airgap (verified by test - suitable for backflow protection against fluid category 5) with a pneumatic or cable operated drop valve capable of full flush volumes of up to 6 litres and reduced flush of up to 4 litres. The cistern is operated by manual push button. Maximum working pressure 10.0 bar. Cold water use only.
BS EN 14055 (2018) concealed WC cistern incorporating a side entry compact type float operated inlet valve discharging via a type `AB` airgap (verified by test - suitable for backflow protection against fluid category 5) and a dual or single flush pneumatic or dual flush cable operated drop valve capable of full flush volumes of up to 6 litres with a reduced flush of up to 4 litres. The cistern is operated by manual push button/push plate. One of the side entry inlet valves is mounted internally and is supplied via a stainless steel braided EPDM lined flexible hose assembly which incorporates a servicing valve. Maximum working pressure 10.0 bar. Cold water use only.
BS EN 14055: 2018 concealed WC flushing cistern incorporating a side entry compact type float operated inlet valve providing a Type AB air gap and lever operated syphon capable of full flush volumes of up to 6 litres and reduced flush of up to 4 litres. Maximum working pressure 10.0 bar. Cold water use only.
BS EN 997:2018 Roca Wall Hung W.C. pan (Ceramic), Thomas Dudley ‘A’ frame incorporating a Thomas Dudley Vantage Concealed cistern. The cistern incorporates a side entry compact type float operated inlet valve providing a Type AG air gap with a dual or single flush pneumatic drop valve capable of full flush volumes of up to 6 litres and a reduced flush of up to 4 litres. The cistern can be operated by a manual push button / push plate options. The inlet valve is mounted internally and supplied via a stainless steel braided EPDM lined flexible hose assembly which incorporates a servicing valve. Maximum working pressure 10.0 bar. Cold water use only.
BS EN 997:2018 Vitra wall hung W.C. pan (Ceramic), Thomas Dudley ‘A’ frame incorporating a Thomas Dudley Vantage Concealed cistern. The cistern incorporates a side entry compact type float operated inlet valve providing a Type AG air gap with a dual or single flush pneumatic drop valve capable of full flush volumes of up to 6 litres and a reduced flush of 3 litres. The cistern can be operated by manual a push button / push plate options. The inlet valve is mounted internally and supplied via a stainless steel braided EPDM lined flexible hose assembly which incorporates a servicing valve Maximum working pressure 10.0 bar. Cold water use only.
BS EN 997:2018 Vitra wall hung W.C. pan (Ceramic), Thomas Dudley ‘A’ or Illusion Compact Universal frame incorporating a Thomas Dudley Vantage Concealed cistern. The cistern incorporates a side entry compact type float operated inlet valve providing a Type AG air gap with a dual or single flush pneumatic drop valve capable of full flush volumes of up to 6 litres and a reduced flush of 3 litres. The cistern can be operated by manual a push button / push plate options. The inlet valve is mounted internally and supplied via a stainless steel braided EPDM lined flexible hose assembly which incorporates a servicing valve. Maximum working pressure 10.0 bar. Cold water use only.
BS EN 997:2018 RAK Compact Rimless Wall Hung 700mm COMRIMWH W.C. pan (Ceramic), Thomas Dudley ‘A’ frame incorporating a Thomas Dudley Vantage Concealed cistern with a side entry compact type float operated inlet valve which discharges via a Type AG airgap and a dual flush pneumatic drop valve capable of full flush volumes of 4.5 litres and a reduced flush of 3 litres. The inlet connection hose incorporates a servicing valve. Maximum working pressure 10.0 bar. Cold water use only.
Double check valve assembly consisting of two spring loaded resilient trim in-line check valve cartridges housed in a DZR brass body with a drain port located between the cartridges. For use with copper pipe manufactured to BS EN1057. Maximum working pressure 16.0 bar. Maximum operating temperature 85°C.
Single hole, single outlet (fixed) combination tap assemblies (chromium plated brass), incorporating a single sequential headwork with a single lever operating member. The spout outlet incorporates a plastic aerator and flow straightener The inlet hoses have integral screwdriver operated isolation valves. Maximum working pressure 5.0 bar. Maximum operating temperature 85°C.
Wall mounted, two-hole, single outlet (fixed) combination tap assembly with brass body (chrome plated), incorporating single sequential headwork with single lever operating member. The inlets incorporate a screwdriver operated servicing valve and an approved check valve cartridge, however, the complete product has not been fully tested to demonstrate it provides backflow protection Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.
Deck mounted, two-hole, single outlet (fixed) concealed combination tap assembly with brass body (chrome plated), incorporating a single sequential headwork with single lever operating member. The inlets incorporate a screwdriver operated servicing valve and an approved check valve cartridge, however, the complete product has not been fully tested to demonstrate it provides backflow protection Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.
Range of deck mounted two hole, single outlet (fixed) combination tap assembly (chromium plated brass) incorporating a single sequential headwork controlling both flow and temperature using a single lever operating member. Inlets incorporate an isolation valve, stainless steel strainers and approved check valve cartridges, however, the complete product has not been fully tested to demonstrate it provides backflow protection. HTMDMRS model is supplied with a removable spout. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.
Wall mounted two hole, single outlet (fixed) combination tap assembly (chromium plated brass) incorporating a sequential headwork controlling both flow and temperature using a single lever operating member. Inlets incorporate an isolation valve, stainless steel strainers and an approved check valve cartridge, however, the complete product has not been fully tested to demonstrate it provides backflow protection. HTMWMRS is supplied with a removable spout. The spout outlets incorporate a plastic flow straightener. Maximum working pressure 5.0 Bar. Maximum operating temperature 60°C.
Range of four-hole, single outlet (fixed) combination tap assemblies (various finishes). Incorporating quarter turn ceramic disc headworks, with various operating members. interconnecting flexible hoses. The spout outlets incorporate a self-cancelling diverter to shower outlet and a plastic flow straightener with stainless steel mesh. The product is supplied with a shower handset that incorporates a single check valve cartridge; however, the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum working pressure 3.5 bar. Maximum operating temperature 60°C.
Range of four-hole, single outlet (fixed) combination tap assemblies, (brass bodies - various finishes), incorporating quarter turn ceramic disc headworks with various operating members and a self-cancelling diverter to shower outlet. The spout outlets incorporate plastic aerators. The products are supplied with a shower hose and metal back nuts. The hose connector incorporates an approved check valve cartridges, however, the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum working pressure 5.0 bar.
Non-metallic materials and components comply with BS6920 at 60°C
Range of basin spout outlets with brass bodies (various finishes), the outlet incorporates either a metal aerators, plastic aerators or open outlet (depending on model). Maximum working pressure 3.5 bar. Maximum operating temperature 60°C
Filling link assembly with a nylon body and EPDM ‘O’-rings. The product incorporates a screwdriver operated shut off valve and two check valve cartridges, verified by test (suitable for backflow protection against Fluid Category 3). The product is also supplied with two screwdriver operated angled spherical valves and a mounting bracket. Maximum working pressure 10.0 bar. Cold water use only.
A range of blue epoxy coated steel reverse rinsing fine filters with a stainless-steel sieve and an EDPM O-ring. Supplied with two pressure gauges and metal ball valve on the drain. Maximum working pressure 16 bar. Maximum operating temperature 40°C.
Range of medical sterilised water filter cartridges with plastic bodies and EPDM ‘O’-Rings. Models MTFW-SLSS / MTFD-SLSS incorporate a check valve cartridge on the inlet, however, the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum Working Temperature: 50°C.
ERA-01 range of SDR11 and SDR17 polyethylene butt welded fittings for use with ERA-02 range of SDR11 and SDR17 PE 100 pipe. SDR11 rated pipe and fittings have a maximum working pressure of 16.0 bar. SDR17 rated pipe and fittings have a maximum working pressure of 10.0 bar. For above and below ground use. Cold water use only.
Ebco Poly B range of compression fittings with gunmetal bodies, for use with PE80 pipe (manufactured to BS EN 12201). For above and below ground use. Maximum working pressure 12.5 bar. Cold water use only.
Single flush pneumatically operated drop valve with a rubber seating washer and ABS body. The valve is operated by a separate push button assembly.
WC dual flush drop valve comprising of a plastic body, silicone seating washer and an internal overflow. The valve is operated via a push button assembly (not included) for either full or reduced flush. Cold water use only.
Range of urinal flushing mechanisms with a solenoid valve controlling the flow. The valves are controlled via an infra-red sensor. The inlet incorporates a stainless steel strainer and flow regulator. Maximum working pressure 10.0 bar. Cold water use only.
Range of stainless-steel plate heat exchangers with EPDM gaskets. The primary circuit, (excluding the E2 prefix models), incorporates a drain valve and a pump (excluding STP prefix models including an ‘N’ as the 14th figure). Operating parameters: Maximum working pressure of the secondary circuit: 6.0 bar or 10.0 bar (see model). Maximum working pressure of the primary circuit: E4 models: 6.0 bar. C3, E3, E2, i2: 10.0 bar. Models added February 2023 – Econoplate STP3, STC3, STP2, STC2 & STP4: 10.0 bar. Maximum operating temperature: Primary 140°C & Secondary 85°C.
Range of under-sink, electrically heated vented water heaters (cased and insulated). Maximum operating temperature 98˚C
Range of wall hung, gas-fired condensing combination boilers providing domestic hot water via a plate heat exchanger and pressure relief valve set at 3.0 bar. The supplies to both primary hot water and secondary are controlled via spherical valves. The boilers incorporate a filling loop assembly which incorporates a double check valve assembly (suitable for backflow protection against Fluid Category 3). Primary circuit: Maximum working pressure 2.5 bar. Maximum operating temperature 82°C. Secondary circuit: Maximum working pressure 10.0 bar. Maximum operating temperature 60°C
Range of gas fired condensing combination boilers providing domestic hot water via a plate heat exchanger. The cold inlet incorporates an angled spherical valve with a brass body, chromium plated brass ball and a lever operating member. The primary circuit incorporates an expansion vessel, isolation valves on flow and return, drain valve and a pressure relief valve set at 3.0 bar. Maximum working pressure of the primary circuit is 2.5 bar. Maximum working pressure of the secondary circuit is 10.0 bar. Maximum operating temperature for the secondary circuit is 55˚C. Cold supply only.
Greenstar Heatslave II range of floor standing oil-fired condensing combination boilers providing domestic hot water via a plate heat exchanger and pressurised central heating system, which incorporates an expansion vessel and pressure relief valve set at 3.0 bar. The cold water inlet incorporates a screwdriver operated spherical valve followed by a plastic flow regulator inserted within the pipework. Maximum working pressure: Primary circuit 2.5 bar. Secondary circuit 10.0 bar. Maximum operating temperature 82°C.
"Greenstar" range of indirect heat interface units and "Flow 8000" (added December 2024) range of direct heat interface units providing heating and instantaneous hot water. The heating system incorporates an expansion vessel. The products are sold with or without a prefix kit (see model), which comprises of a mounting bracket that includes spherical valves for all circuits. The "Greenstar" indirect models include a pressure relief valve (set at 3.0 bar) on the space (central) heating circuit. Greenstar models: Maximum working pressure district heating 10.0 bar. Maximum working pressure space heating 2.5 bar. Maximum working pressure secondary hot water 10.0 bar. Maximum operating temperature 60°C (secondary) and 90°C (primary). Flow 8000 models (added December 2024): Maximum working pressure district and space heating 10.0 bar. Maximum working pressure secondary hot water 10.0 bar. Maximum operating temperature 60°C (secondary) and 90°C (primary).
Range of wall mounted, gas-fired, condensing combination boilers providing domestic hot water via a plate heat exchanger. The pressurised central heating system incorporates an expansion vessel and a pressure relief valve set at 3.0 bar. The inlets to the domestic hot water and primary circuits each have a screwdriver operated angled spherical valve. Both include a ½” BSP (M) connection for a filling link. The Greenstar CDi models only are supplied with an integral charging link (CAB device) verified by test (suitable for backflow protection against Fluid Category 3). Maximum working pressure of the primary circuit is 2.5 bar. Maximum working pressure of the secondary circuit is 10.0 bar. Maximum operating temperature of primary circuit is 82°C. Maximum operating temperature of secondary circuit is 60°C.
Range of electric combination boilers providing heating and instantaneous hot water. The heating system incorporates an expansion vessel and pressure relief valve (set at 3.0 bar). The DHW inlet and outlet incorporate spherical servicing valves. Fittited with a CAB device keyless filling link, verifired by test, suitable for category 3 backlfow protection. Maximum working pressure on central heating circuit 2.5 bar & Domestic Hot Water 10bar. Maximum operating temperature 80°C
Hydraulic block assembly comprising a flow sensor, primary pump assembly, pressure relief valve preset at 3.0 bar and plate heat exchanger. Maximum working pressures: secondary = 10.0 bar and primary = 2.5 bar. Maximum operating temperature 80°C.
Hydraulic block assembly comprising of a flow regulator, central heating pump assembly and a stainless-steel plate heat exchanger. Maximum working pressures: DHW circuit: 10.0 Bar Central heating circuit: 2.5 Bar Maximum operating temperature: DHW Circuit: 65.0°C Central heating circuit: 90.0°C
Hydraulic block incorporating heat exchangers with pressed stainless-steel plate bodies and copper brazing. Product also incorporates primary and secondary water way with PPS plastic fittings and adaptors and a flow adjustment valve. Maximum operating temperature: Central Heating Circuit: 90°C, Direct Hot Water Circuit: 65°C. Maximum working pressure: Central Heating Circuit: 2.5 bar, Direct Hot Water Circuit: 10 bar.
MJ (Multi jet) range of water meters with either ductile iron (MJF model) or brass (MJ models) blue epoxy coated bodies and EPDM rubber ‘O’-rings. Maximum working pressure16.0 bar. Maximum operating temperature 85°C.
Water meter with a DZR brass body, stainless steel temperature sensors and EPDM ‘O’-rings. The inlet incorporates a plastic strainer. Maximum working pressure 16.0 bar. Maximum operating temperature 85°C.
‘RSM’ range of ultrasonic water meters with blue epoxy coated ductile iron bodies, stainless steel transducer and EPDM ‘O’-rings. Maximum working pressure 16.0 bar. Maximum operating temperature 50°C.
Range of ‘Resident Valves’ with a DZR brass body consisting of water meter manifold, an isolation valve on the inlet, a pressure reducing valve (adjustable between 1.5 and 6.0 bar) and 2 non-return valves which are located on the outlet of the water meter manifold. The ‘Plus’ models are also supplied with an isolation valve on the outlet, which incorporates a drain tap. Maximum supply pressure 16.0 Bar. Cold water above ground use only.
Range of water meter manifolds with gun metal bodies and ball valve with either a quarter turn stop valve or screw down stop valve. The products incorporate an approved check valve cartridge however, the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum working pressure 16.0 bar. Cold water use only.
Range of meter boxes incorporating a plastic manifold arrangement consisting of a stop valve with non-rising spindle , check valve (however the complete assembly has not been tested to demonstrate it provides adequate backflow) and concentric meter port. Some models incorporate a drain off or blacking plug. Connections can be compression or push fit (see model). For use with PE8-0 pipe to BS EN 12201 and copper to EN 1057. Maximum working pressure 16.0 bar. Cold water use only.
Range of pushfit hose connectors with either plastic (white or black) or chrome plated brass bodies and EPDM ‘O’-rings. SHCV prefix models incorporate screwdriver operated servicing valves. All pushfit connections are for use with PEX pipe (manufactured to BS7291-3) and copper pipe (manufactured to EN1057). Barbed end connections are not approved for use with any hose. Chrome plated brass body models are also for use with PB pipe (manufactured to BS7291-2). Maximum working pressure 10.0 bar (servicing valve models only). Barbed end connections are open outlet use only. Cold water use only.
Range of pump inverters with plastic bodies, NBR rubber and EPDM rubber seals and ‘O’-rings. The products incorporate an inline resilient trim non-return valve. Maximum working pressure 13.0 bar. Cold water use only.
Range of concealed thermostatic mixing valves with DZR brass bodies incorporating a thermostatic cartridge controlling the temperature. The inlets incorporate asingle check valve cartridges, however, the complete product has not been fully tested to demonstrate it provides backflow protection Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.
Permanent filling/ pressurisation device for primary heating and chilled water closed circuits in domestic and non-domestic premises. The mains and closed circuit system pressures are continuously checked by two pressure sensors and their differential monitored by microprocessors. In the event of a fall in system pressure, and only if the mains pressure is adequate, a solenoid valve operates to allow water into the system. At all other times a second solenoid valve drains the fill chamber to waste, via tundish (meeting the requirements of an air gap to drain), and allowing air to be admitted via an automatic air vent to create an atmospheric disconnection across the transfer chamber. Maximum working pressure 6.0 Bar. Cold water use only.
‘e-SH’ range of centrifugal booster pumps with a blue polymer coated stainless steel body, stainless steel impeller and EPDM ‘O’-rings. Maximum working pressure 12.0 bar. Cold water use only.
Range of cold water in tank booster sets incorporating an ‘AG’ air gap, consisting of a GRP water storage cistern incorporating a float operated inlet valve, with a copper float and submersible pump or pumps (depending on model). The products incorporate an externally mounted stainless-steel manifold with servicing valve(s), expansion vessel, pressure gauge and a digital control panel. The pumps are connected to the external components via a discharge assembly of internal pipework including an in-line non-verifiable single check valve assembly (suitable for backflow prevention of Fluid Category 2). Maximum working pressure 10.0 bar. Cold water use only.
Page 4 of 21
We use cookies to give you the best possible experience with WRAS. Some are essential to provide website functions and ensure the website is secure. We also use cookies to help us understand how people use the site and to make improvements. Click "Accept All" to enable recommended settings or click "Manage cookies" to adjust your settings. For more details, see our Cookie Policy.