Range of single hole, single outlet (swivel) combination tap assemblies with (brass bodies – various finishes), incorporating ceramic cartridge headworks with single lever operating members. The spout outlets incorporate a plastic aerator. Maximum working pressure 10.0 bar. Maximum operating temperature 65°C.
Range of floor mounted single hole, single outlet (swivel), combination tap assemblies (brass bodies – various finishes), incorporating a ceramic cartridge headwork with a single lever operating member and a manual diverter to shower outlet. The spout outlet incorporates a plastic aerator. The product is supplied with a shower hose and handset. Maximum working pressure 5.0 Bar Maximum operating temperature 60.0°C.
Wall mounted two-hole, single outlet (fixed) combination tap assembly (chromium plated brass) incorporating detent headworks controlling flow to either bath or shower. A thermostatic cartridge controlling the temperature incorporating a manual override button. The spout outlet incorporates a plastic aerator. Inlets incorporate a approved check valve cartridges, however, the complete product has not been fully tested to demonstrate it provides backflow protection. The product is supplied with a shower hose, handset and overhead shower. Maximum working pressure 10.0 Bar Maximum operating temperature 60.0°C
Range of two hole, single outlet (fixed), combination tap assemblies with (brass bodies - various finishes) incorporating quarter turn ceramic disc headworks with single lever or dome type operating members (see models). The products are supplied with metal back nuts. Maximum working pressure 10.0 bar.
Non-metallic materials and components comply with BS6920 at 65°C
Range of two-hole, single outlet (fixed) combination tap assemblies (brass body – various finishes), incorporating quarter turn ceramic disc headworks with single lever operating members. The spout outlet incorporates a plastic aerator, and the product is supplied with metal backnuts. Maximum working pressure 5.0 Bar. Maximum operating temperature 60.0°C.
Range of two hole, single outlet (fixed) wall mounted combination tap assemblies (chromium plated brass spout) incorporating a ceramic cartridge headwork with a joystick operating member. The spout outlet incorporates a plastic flow straightener. Maximum working pressure: 10.0 bar. Maximum operating temperature: 60°C.
Range of wall mounted, two-hole, single outlet (fixed) combination tap assemblies (brass bodies – various finishes), incorporating a ceramic cartridge headwork with a single lever operating member. The spout outlet incorporates a plastic aerator. Maximum operating pressure 10.0 bar. Maximum operating temperature 85°C.
Range of two-hole, single outlet (fixed) combination tap assemblies, (brass bodies - various finishes), incorporating quarter turn ceramic disc headworks with single lever type operating members and a manual diverter to shower outlet. The products are supplied with metal back nuts. Maximum working pressure 10.0 Bar
Non-metallic materials and components comply with BS6920 at 65°C
Range of two-hole, single outlet (fixed) combination tap assemblies (brass bodies - various finishes), incorporating quarter turn ceramic disc headworks with single lever operating members and manually operated diverter to shower outlet. The spout outlets are open out or incorporate a plastic flow straightener. Incorporates a non-rising spindle headwork with cross-top type operating members. Products are supplied with metal back nuts, hoses and shower handsets. Maximum working pressure 6.0 Bar Maximum operating temperature 60.0°C
Range of deck mounted two-hole, single outlet (fixed) combination tap assemblies (brass bodies - various finishes), incorporating quarter turn ceramic disc headworks with single lever operating members and a manually operated diverter to shower outlet. The spout outlet incorporates a plastic aerator, and the product is supplied with shower hose and handset (with flow regulator) and metal backnuts. Maximum working pressure 5.0 Bar. Maximum operating temperature 60.0°C.
Range of wall mounted, two-hole, single outlet, (fixed), combination tap assemblies (chromium plated brass bodies) incorporating ceramic cartridge headworks with single lever operating members and self-cancelling diverter to shower outlet. The spout outlet incorporate a plastic aerator. Maximum operating pressure 10 bar. Maximum operating temperature 60°C
Range of two-hole, single outlet (swivel) combination tap assemblies (brass bodies, various finishes - see model) incorporating a ceramic cartridge headwork with a dome type operating member. The spout outlet incorporates a plastic aerator. The headwork is connected to the spout via a stainless steel braided PEX lined flexible hose assembly. Maximum working pressure 10.0 bar. Maximum operating temperature 60.0°C
Range of deck mounted, three-hole, single outlet (fixed) combination tap assemblies (brass body - various finishes). The products incorporate 1/4 turn ceramic disc headworks with single lever, dome type, cubed or cross top operating members. The spout outlets incorporate plastic aerators. The products are supplied with stainless steel braided PEX lined flexible hose assemblies for connection between the side valves and the spout and click type pop-up wastes (verified by test). Maximum working pressure 3.5 Bar. Maximum operating temperature 60.0°C.
Three hole, single outlet (swivel) combination tap assemblies (brass bodies - various finishes), incorporating quarter turn ceramic disc headworks with cross top or lever type operating members. The spout outlets incorporate a plastic aerator. The products are supplied with stainless steel braided PEX lined flexible connecting hose assemblies, for use between side body valves and spout. Maximum working pressure - 10 Bar. Maximum operating temperature - 70°C.
Range of five-hole, single outlet (fixed) combination tap assemblies with a brass body, incorporating quarter turn ceramic disc headworks with single lever or cross top operating members. The products have a self-cancelling operated diverter to shower outlet and are supplied with a shower hose, shower handset and interconnecting braided hoses. The spout outlet incorporates a plastic flow aerator. Maximum working pressure 5 bar. Maximum operating temperature 60°C.
Range of single hole, single outlet (fixed) combination tap assemblies (various finishes - see model). Electronic controls on the left-hand side of the body allow the tap to dispense one or more of the following (model specification dependent): boiling, chilled or sparkling water. Ambient (hot and cold) water is controlled via a ceramic cartridge headwork with a single lever operating member. The spout incorporates a plastic aerator on the Sparkling/Chilled and the Ambient outlet, and a separate outlet for the boiling water. Both model ranges incorporate a vent outlet within the tap spout for the boiling water circuit. Maximum working pressure 5.0 bar (Ambient (hot and cold) circuit only). 95458xxx models - Boiling circuit has a maximum operating temperature of 100°C. All other circuits have a maximum operating temperature of 65°C. 95459xxx models - Boiling circuit has a maximum operating temperature of 100°C. The ambient circuit has a maximum operating temperature of 65°C. The chilled/sparkling circuit has a maximum operating temperature of 60°C.
Zilmet range of cylindrical or tubular expansion vessels, epoxy coated carbon steel bodies with either Butyl or EPDM membranes and stainless-steel or galvanized carbon-steel connections. Please refer to models for maximum working pressures, as this varies by model and size. Maximum operating temperature 65°C.
Range of filling loop assemblies, consisting of: A nickel plated DZR brass bodied isolation valve with chrome plated DZR brass ball and integral non-verifiable double check valve assembly, verified by test (suitable for backflow protection against Fluid Category 3). A stainless-steel braided EPDM lined flexible hose assembly. An isolation valve with a nickel plated DZR brass body and a chrome plated DZR brass ball. The HLD14.12.049 model is supplied with a lanyard and cap end for each valve. The compression connections are for use with copper pipe (manufactured to BS2871). Maximum working pressure 10.0 Bar. Maximum operating temperature 85°C.
Range of filter cartridges. Maximum working pressure 8.0 Bar. Cold water use only.
Hep2O range of polybutylene fittings for use with Hep2O PB barrier pipe. In May 2024, Next generation (G5) of Hep20 pushfit fittings for use with the Hep20 range of PB barrier pipe, were added to the approval. Maximum working pressure 10.0 bar at 95°C.
Range of M type press copper crimp fittings with EPDM ‘O’-rings for use with copper tube manufactured to EN 1057. The joints are achieved by means of a crimping tool. For above ground use. Maximum working pressure: 16.0 bar. Maximum operating temperature: 85°C
‘SR’ range of capillary solder ring copper fittings for use with copper tube EN1057, for above ground use only. Maximum working pressure: 25.0 bar. Maximum operating temperature: 85°C.
‘SharkBite’ range of brass push fit fittings incorporating an EPDM ‘O’-ring. For use with the following pipes: JG Speedfit Layflat Polybutylene Barrier Pipe (JG BPB pipe manufactured to BS EN 7291-2:2010), 'BPEX' Barrier Pipe (JG BPEX pipe manufactured to BS EN 7291-3:2010), Polybutylene barrier pipe (manufactured to BS EN 7291-2:2010), PEX barrier pipe (manufactured to BS EN 7291-3:2010) and Copper pipe (manufactured to BS EN1057:2006). Maximum working pressures and operating temperatures: When used with Polybutylene barrier pipes (manufactured to BS EN 7291-2:2010) and PEX barrier pipes (manufactured to BS EN 7291-3:2010): 12.5 bar, cold water use only. 6.0 bar @ 95°C. When used with copper pipe (manufactured to BS EN1057:2006): 10mm sizes: Maximum working pressure 16.0 bar. Cold water use only. Maximum working pressure 10.0 bar. Maximum operating temperature 95°C. 15-22mm sizes: Maximum working pressure 20.0 bar. Cold water use only. Maximum working pressure 16.0 bar. Maximum operating temperature 95°C. 28mm size added April 2024: Maximum working pressure 20.0 bar. Cold water use only. Maximum working pressure 16.0 bar. Maximum operating temperature 95°C.
Range of Redman fittings with mild steel bodies (polyamide coating) for use with Radius Systems Puriton Light Blue Barrier Pipe [Type A, BS8588] & Puriton Dark Blue Barrier Pipe [Type A, BS8588]. For above and below ground and cold-water use. Jointing is achieved by hydraulic compression. Maximum working pressures: 12.5 Bar for 63mm SDR 11 PE80 pipe system, 10.0 Bar for 90mm to 180mm SDR 17 PE100 pipe system, 16.0 bar for 90mm to 180mm SDR 11 PE100 pipe system. Cold water use only.
Range of end feed copper fittings for use with copper tube manufactured to EN1057, for above ground use only. Maximum working pressure 25.0 bar. Maximum operating temperature 85℃.
Dual flush WC outlet valve comprising of plastic body, silicone seal and an internal overflow. Valve is operated via a dual push button for either full or reduced flush. Cold water use only.
Range of WC flush valves with an ABS body and silicon seal. The valves are operated via a push button assembly for either full or reduced flush and incorporate an internal adjustable height overflow. Cold water use only.
Range of plate heat exchangers with pressed stainless steel plate bodies and copper brazing. Available with threaded or flat face seal connection (see model). Maximum working pressure varies by model: ZT190 & ZT207 - 8.0 bar; ZB190, ZB195, ZB200, ZB207 & ZB315 - 10.0 bar; ZC315 (flat face seal version only) - 16.0 bar; ZC190, ZC207, ZC315 (threaded only) & Z(B-C-E) 250, 400, 450, 500 – 30.0 bar or 45.0 bar (models with additional upper and lower plates only); ZB600 & ZB700 - 30.0 bar. Maximum operating temperature 99°C.
Range of wall mounted combination boilers providing domestic hot water via a plate heat exchanger and pressurised central heating system. The primary circuit incorporates a pressure relief valve set at 3.0 bar and an expansion vessel. The secondary circuit (DHW) incorporates a plastic flow restrictor and stainless-steel filter. The primary and secondary circuit incorporates isolation valves on the flow and the primary also has one on the return. Maximum working pressures: Secondary DHW: 10.0 Bar Primary CH: 2.5 Bar Maximum operating temperatures: Secondary DHW: 65.0°C Primary CH: 85.0°C
Range of water meter housings. The 4414-WMH-20 (threaded) model has a DZR brass body and a check valve cartridge on the inlet verified by test (suitable for backflow protection against Fluid Category 2). The 4414-WMH-1 & 4414-WMH-2 (compression) models have a brass body and an approved check valve cartridge on the inlet, however, the complete product has not been fully tested to demonstrate that it provides adequate backflow protection. The compression models are for use with copper pipe (manufactured to EN 1057). Maximum operating pressure 16.0 bar. Maximum operating temperature 85°C.
Range of flow sensors with plastic bodies and rotors. Maximum working pressure: 10 Bar. Maximum operating temperature: 80°C.
Range of stainless steel bodied mechanical pump shaft seals. The 491 model comprises of carbon and silicone carbide seal faces and EPDM ‘O’-rings. The 1510 model comprises of carbon and silicone carbide seal faces, EPDM ‘O’-rings and an orange NBR/aramid fibre gasket. Maximum operating temperature 100°C.
Range of concealed rough-in sets with brass bodies, intended for use in conjunction with trim and finish sets. Maximum working pressure 10.0 Bar Maximum operating temperature 85.0°C
‘SCALA 2’ integrated, self-priming, plastic bodied (compact) mains pressure boosting pump. Maximum working pressure 10.0 bar. Cold water use only.
`UPM3` range of single stage circulator pumps, with stainless steel or plastic bodies, plastic impellers, ceramic shafts and bearings, EPDM 'O'-rings and seals. Maximum working pressure 10.0 bar. Maximum operating temperature 99°C.
Range of horizontal self-priming multistage pumps with stainless steel bodies, stainless steel impellers, shaft and outer sleeve. Maximum working pressure 10.0 Bar Maximum operating temperatures: MH Three phase models 85°C, MH Single phase models 55.0°C and EH sp models 35°C.
Range of shower outlets comprising of shower handsets (brass bodies – various finishes) and overhead showers (stainless-steel bodies – various finishes), incorporating stainless-steel strainer washer. Model (CPH05013) incorporates a flow limiter in the inlet. Maximum operating temperature 85°C.
Range of shower handsets, plastic bodies. Maximum operating temperature 70 °C.
Range of shower outlets incorporating brass bodies (various finishes) and NBR ‘O’-rings. Maximum operating temperature 85°C.
A range of ABS plastic shower handsets, (various finishes - see model). Maximum operating temperature 60°C.
Range of shower arms and brackets (brass or stainless steel bodies - various finishes). Open outlet use only. Maximum operating temperature 85°C.
Range of chromium plated brass shower outlets, shower arms and ceiling connectors. Model 26 034 xxx is supplied with a shower arm, and model 26 035 xxx is supplied with a ceiling connector. Maximum operating temperature 60.0°C. Open outlet use only.
Range of overhead shower outlets with chrome plated plastic bodies. The inlets incorporate a flow regulator. Maximum operating temperature 60.0°C Open outlet use only.
Range of nylon braided (DG50X model series) or stainless steel braided (DG10X model series), PEX lined flexible hose assemblies with a variety of end connections (see models for full breakdown), including EPDM washers and ‘O’-rings where applicable. Some models are supplied with screwdriver operated isolation valves (see model list). All compression and push-fit fittings are to be used with copper pipe (manufactured to EN 1057). Maximum working pressure: 16 bar. Maximum operating temperature: 85°C.
Range of stainless steel or brass interlocked hose with PEX inner hose and various connections and finishes (see models). Open outlet use only. Maximum operating temperature 85°C.
Range of nylon braided (DG50E model series) or stainless steel braided (DG10E model series), EPDM lined flexible hose assemblies with a variety of end connections (see models for full breakdown), including EPDM washers and ‘O’-rings where applicable. Some models are supplied with screwdriver operated isolation valves (see model list). All compression and push-fit fittings are to be used with copper pipe (manufactured to BS EN 1057). Maximum working pressure: 16 bar. Maximum operating temperature: 85°C.
Range of cased and insulated stainless steel unvented water storage heaters. The DHW circuit includes a factory fitted combined temperature and pressure relief valve set at 6.0 bar and 90˚C. The product can be supplied with two possible safety kits (inlet control groups). One includes a pressure reducing valve adjustable between 1.5-6.0 bar, (but set at 3.0 bar), a check valve cartridge, verified by test (suitable for backflow protection against Fluid Category 2) and a pressure relief valve pre-set at 4.5 bar. The other includes a pressure reducing valve pre-set at 3.0 bar, an approved check valve cartridge, however, the complete product has not been fully tested to demonstrate it provides backflow protection, and a pressure relief valve pre-set at 4.5 bar. The product is also supplied with an expansion vessel and a tundish. The compression connection of each inlet control group is for use with the following pipes: Both for use with copper pipe (manufactured to BS EN 1057). The inlet control group without an adjustable pressure reducing valve can also be used with PB pipe (with inserts) (manufactured to BS EN 7291-2:2010) and PEX pipe (with inserts) (manufactured to BS EN 7291-3:2010). Maximum supply pressure to inlet control group pressure reducing valve: 16.0 bar. Maximum working pressure 4.0 bar. Maximum operating temperature 99°C. Cold supply only.
Range of wall mounted, manually operated blending valves with (brass bodies - various finishes), incorporating ceramic cartridge headworks and single lever or dome type operating members and a self-cancelling diverter to shower outlet. Maximum working pressure 10.0 Bar Maximum operating temperature 70.0°C
Range of wall mounted, exposed, thermostatic shower valves (chromium plated brass) incorporating a single sequential headwork controlling both flow and temperature with a single lever operating member. The products are supplied with 15mm compression inlet elbows incorporating approved check valve cartridges, however, the complete product has not been fully tested to demonstrate it provides backflow protection. The inlets also incorporate plastic flow regulators. The 90033CP model can have either a top or bottom outlet, which is achieved by re-positioning the blanking plug and threaded outlet. The compression connections are for use with copper pipe (manufactured to EN 1057). Maximum working pressure 10.0 bar. Maximum operating temperature 65°C.
A range either concealed or exposed wall mounted thermostatic mixing valves with brass bodies (exposed models are chromium plated). Incorporates ¼ turn ceramic disc headworks. The inlets of all models expect F3004 incorporate stainless steel filters and approved check valve cartridges; however, the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum working pressure 10 bar. Maximum working temperature 60°C.
Page 66 of 131
We use cookies to give you the best possible experience with WRAS. Some are essential to provide website functions and ensure the website is secure. We also use cookies to help us understand how people use the site and to make improvements. Click "Accept All" to enable recommended settings or click "Manage cookies" to adjust your settings. For more details, see our Cookie Policy.