Range of two hole,wall mounted, concealed, tap assemblies, including spout outlet, trim set and single lever operating members (various finishes). The spout outlet incorporates a plastic flow straightener and a plastic flow regulator on the inlet. Maximum working pressure 10 bar. Maximum working temperature 60°C.
Range of two-hole, single outlet (fixed) combination tap assemblies (chromium plated brass) incorporating ceramic disk headworks with single lever operating members and manually operated diverters to shower outlets. The spout outlets incorporate plastic aerators (T7111, T739001 & T740001) or plastic flow straightners (T7501M & T749001),except model T8701 that has an open spout outlet. The products are supplied with metal backnuts. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C. Maximum working pressure 10.0 bar. Maximum operating temperature 65°C (on model T740001).
Range of two-hole, single outlet (fixed) combination tap assemblies, (chrome plated brass bodies) incorporating quarter turn ceramic disc headworks with single lever operating members and a manual diverter to the shower outlet. The products are supplied with a shower hose, handset and metal backnuts. Maximum working pressure 10.0 bar. temperature 75°C.
A range of two-hole, single outlet, fixed, combination tap assemblies (chrome plated brass bodies), incorporating quarter turn ceramic disc headworks with single lever operating members and a manual diverter to a shower outlet. The spout outlet incorporates plastic aerators or flow straightener and is supplied with metal backnuts. The products are supplied with a shower hose, handsets and metal backnuts. Maximum working pressure 10 bar.
Range of two-hole, single outlet (fixed) combination tap assemblies (chromium plated brass), incorporating quarter turn ceramic disc headworks and a manual diverter to shower outlet. The spout outlet incorporates a plastic flow straightener. Products are supplied with a shower hose and handset and plastic backnuts. Maximum working pressure 6.0 Bar.
Range of deck mounted, two-hole, single outlet (fixed) combination tap assembly (chromium plated brass), incorporating a half-turn ceramic disc headwork, both controlling the flow and manually diverting the flow to a shower outlet connection. Temperature is controlled independently via a thermostatic cartridge. The spout outlet incorporates a plastic aerator. Both inlets incorporate an approved single check valve cartridge (however, the complete assembly has not been fully tested to demonstrate that it provides adequate backflow protection) and stainless-steel strainers. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.
Non-metallic materials and components comply with BS6920 at 60°C
Wall mounted bath shower mixer with brass body (various finishes). Ceramic disc headwork with dome operating members, manually operated diverter to shower outlets. The temperature is controlled independently via a thermostatic cartridge using a single lever operating member. Both inlets incorporate an approved single check valve cartridge (however, the complete assembly has not been fully tested to demonstrate that it provides adequate backflow protection). Spout outlet incorporates a plastic aerator. Products are supplied with shower headhead, shower handset and shower hose. Maximum operating pressure 10 Bar. Maximum operating temperature 85°C.
Wall mounted two-hole, single outlet (fixed) combination tap assembly (brass bodies - various finishes) incorporating a ceramic cartridge headwork with a single lever operating member, and a self-cancelling diverter to shower outlet. The spout outlet incorporates a plastic aerator. Maximum working pressure 10.0 Bar.
Non-metallic materials and components comply with BS6920 at 70°C
Range of wall mounted, two hole, single outlet (fixed) combination tap assemblies (chromium plated brass), incorporating a quarter turn ceramic disc headwork with a dome type operating member. The temperature is controlled independently via a thermostatic cartridge incorporating a dome type operating member and a manual override button. Each inlet incorporates a combined NBR washer and stainless steel strainer, and an approved check valve cartridge, however, the complete product has not been fully tested to demonstrate it provides backflow protection. The spout outlet incorporates a self cancelling diverter to shower outlet and a plastic flow straightener. Maximum working pressure 10.0 bar.
Non-metallic materials and components comply with BS6920 at 65°C
Two-hole, single outlet (swivel) combination tap assembly (chromium plated brass), incorporating quarter turn ceramic disc headwork with single lever operating members. The spout outlet incorporates a plastic aerator and the product is supplied with plastic back-nuts. Maximum working pressure 5.0 bar.
Non-metallic materials and components comply with BS6920 at 60°C
Range of two-hole, double outlet, fixed combination tap assemblies (chrome plated brass bodies), incorporating quarter turn ceramic disc headworks with single lever operating members. The products are supplied with metal back nuts. Maximum operating pressure 6 bar. Maximum operating temperature 85°C
Range of wall mounted, concealed, three hole single outlet (fixed) combination tap assemblies with brass bodies (various finishes), incorporating quarter turn, ceramic disc headworks with cross top (14415W-3-CP) or single lever (14415W-4-CP) operating members. The spout outlet incorporates a plastic aerator. Maximum operating temperature 60°C. Maximum operating pressure 4.1 bar.
Range of deck mounted three hole single outlet (fixed) combination tap assemblies with brass bodies (chromium plated), incorporatinig ceramic disc headworks with cross top (14428W-3-CP) or single lever (14428W-4-CP) operating members. The product is supplied with stainless-steel braided EPDM lined flexible hose assemblies to connect the headworks to the spout outlet. Spouts incororate plastic flow straightners. Maximum working pressure 5 bar. Maximum operating temperature 60°C
Range of wall mounted, three-hole, metal, single outlet (fixed), combination tap assemblies (concealed brass body, various finishes - see model), incorporating quarter turn ceramic disc headwork with single lever, cross top or dome type operating members (see model). The spout outlet incorporates a plastic aerator (F7 & F9 prefix models only). Maximum working pressure 10.0 bar.
Non-metallic materials and components comply with BS6920 at 65°C
Range of three-hole, single outlet (swivel) combination tap assembly incorporating brass body - various finishes) and quarter turn ceramic disc headwork with single lever operating members. The spout outlets incorporate a plastic aerator. Maximum working pressure 10.0 bar
Non-metallic materials and components comply with BS6920 at 60°C
Range of deck mounted, four hole, single outlet (fixed) combination tap assemblies (chromium plated brass), incorporating a 2-way ceramic disc diverter headwork controlling the flow between the spout and shower outlet. Temperature is controlled independently by a thermostatic cartridge. The ARR-132T-CP model has single lever operating members and the ARR-232T-CP model has cross top operating members. Each inlet incorporates an approved check valve cartridge however, the complete product has not been fully tested to demonstrate it provides backflow protection. The spout outlet incorporates a plastic aerator. The product is supplied with a shower hose and handset, and has metal backnuts. Maximum working pressure 5.0 bar.
Non-metallic materials and components comply with BS6920 at 60°C
Range of combined bath fillers and overflow waste assemblies (plated brass covers and plastic hoses) with pop-up wastes. Maximum operating temperature 65ºC. Open outlet use only.
Spout outlet, (chrome plated brass body) incorporating EPDM ‘O’ rings. The outlet incorporates a plastic flow straightener.
Non-metallic materials and components comply with BS6920 at 50°C
Range of wall mounted spouts with a brass body (various finishes, see model). The outlet incorporates a plastic aerator. Maximum operating temperature - 60°C
Spout outlet consisting of a chromium plated brass body, plastic aerator and EPDM ‘O’ rings. Maximum operating temperature 60°C.
Range of QSL stainless-steel expansion bellows with either threaded or flanged end connections. Maximum working pressure: See models. Maximum operating temperature 99°C.
Range of welded stainless steel (S30408 or S31603) pipes. Maximum working pressure 25.0 bar. Maximum operating temperature 100°C.
`Vortex air` range of free-standing hospital macerators with flow controlled by solenoid valve and discharged via type AB air gap assembly (verified by test - suitable for backflow protection against fluid category 5). Maximum working pressure 9.0 bar. Cold water use only.
Range of expansion vessels with stainless steel bodies incorporating a butyl rubber membrane. Maximum working pressure 10.0 bar. Maximum operating temperature 99°C.
Range of filling loop assemblies consisting of an in-line isolation valve, an in-line double check valve assembly (suitable for back flow protection against fluid category 3) that incorporates an isolation valve and a stainless-steel braided EPDM lined hose. Models ALT-ST0019 & ALT-ST0019 are supplied with a pressure gauge. Maximum working pressure 10.0 bar. Maximum operating temperature 85°C.
Non-metallic materials and components comply with BS6920 at 85°C
Range of filling loop assemblies consisting of an in-line isolation valve, an in-line double check valve assembly (suitable for back flow protection against fluid category 3) that incorporates an isolation valve and a stainless-steel braided EPDM lined hose. Maximum working pressure 10.0 bar. Maximum operating temperature 85°C.
Non-metallic materials and components comply with BS6920 at 85°C
Range of in-line water filters with polypropylene bodies. Maximum working pressure 8.5 bar. Cold water use only.
Non-metallic materials and components comply with BS6920 at cold water use only°C
Range of in-line water filters with polypropylene bodies. Maximum working pressure 8.5 bar. Cold water use only.
Non-metallic materials and components comply with BS6920 at cold water use only°C
Stainless steel press fittings for use with 316L & 304 stainless steel tube incorporating EPDM ‘O’ rings. The fittings and tube are assembled using a crimping tool. For above ground use only. Maximum working pressure 16.0 bar. Maximum operating temperature 99°C.
“D” Range of stainless steel (304S31/316S11) press fittings for use with ‘DPX’ series 1 & 2 stainless steel (304S31/316S11) pipe. The fittings and tube are assembled using a crimping tool. Maximum working pressure 16.0 bar. Maximum operating temperature 99°C.
Range of copper and brass press-fit fittings with HNBR o-rings, for use with copper tube manufactured to EN1057. Maximum working pressure 16.0 bar. Maximum operating temperature 85°C.
Range of DZR brass push fit fittings for use with copper pipe (manufactured to BS EN 1057), PB pipe (manufactured to BS7291-2) and PEX pipe (manufactured to BS7291-3). Maximum working pressures and operating temperatures: 12.5 @ 20°C, and 3.0 bar @ 92ºC.
Range of press fittings with a stainless steel body and EPDM ‘O’ rings for use with stainless steel 316L pipe manufactured to EN10312. For above ground use only. Maximum working pressure 16.0 bar. Maximum operating temperature 85°C.
alpex Duo XS and alpex L (PPSU & Brass) ranges of press fittings for use with alpex Duo XS (F and TH press profiles) & alpex L pipe (F press profile only). Maximum working pressure 10.0 bar. The maximum operating temperature is 95oC.
PLAS-FIT range of polypropolene fittings for use with PE pipe (manufactured to EN 12201). Maximum working pressure 16 bar. Cold water use.
Range of Conex >B< press fittings incorporating copper & brass bodies for use with copper tube (manufactured to EN1057). Maximum working pressure 16.0 bar.
Non-metallic materials and components comply with BS6920 at 85°C
Range of copper end feed solder fittings for use with copper tube (EN1057). For above and below ground use. Maximum working pressure for sizes 8mm to 54mm is 25.0 bar. Maximum working pressure for sizes above 54mm is 16.0 bar. Maximum operating temperature 99°C.
Range of wall mounted combination boilers providing domestic hot water via a heat exchanger and pressurised central heating system. The products can be supplied with a rigid or flexible filling loop or keyless filling link. The flexible and rigid filling loops incorporate a flexible hose or copper pipe, isolation valve, double check valve assembly (suitable for back flow protection against fluid category 3). The keyless filling link incorporates a CAB backflow prevention device (suitable for back flow protection against fluid category 3). The products also incorporate an expansion vessel and pressure relief valve set at 3.0 bar. Maximum working pressure of primary circuit 2.5 bar. Maximum operating temperature of primary circuit 85°C Maximum working pressure of secondary circuit 8.0 bar Maximum operating temperature of secondary circuit 60°C
Preheat accessory assembly for connection to the domestic hot water circuit of a combination boiler. Incorporates flow sensor, flow restrictor, flow silencers, pre-heat sensor and filter. Maximum working pressure 10.0 bar. Maximum operating temperature 85°C.
Conealed wall mounted installation set with a brass body. Maximum working pressure 10 bar. Maximum operating temperature 70°C
Range of vertical multistage pumps with cast iron bodies with a black electrodeposition coating, stainless-steel impellers, shaft and outer sleeve. Maximum working pressure: MVX 30 & MVX 45- 32.0 bar, MVX 65 & MVX95 VR - 25.0 bar. Cold water use only.
Range of circulating pumps with a bronze body, plastic impeller and EPDM gaskets. Maximum working pressure 10.0 bar. Maximum operating temperature 85°C.
Range of shower heads with a chromium plated brass bodies, with stainless-steel strainer plastic flow regulator on the inlet. Models P42802 & P45300 have plastic bodies.
Non-metallic materials and components comply with BS6920 at 60°C
Range of shower handsets with chrome plated plastic bodies. Some models incorporate a plastic aerator at the outlet of the shower and/or a plastic flow regulator and strainer on the inlet.
Non-metallic materials and components comply with BS6920 at 60°C
Range of overhead shower outlets with brass bodies (various finishes, see model), with stainless steel strainers and EPDM O-rings at the inlets. Models 26295W-** & 26295W-G-** are also supplied with flow regulators. Maximum operating temperature 60°C.
Shower kit comprising of chrome plated wall mounted shower outlet, shower hose and handset. The inlet incorporates a stainless-steel strainer and an approved check valve cartridge; however, the complete product has not been fully tested to demonstrate it provides backflow protection.
Non-metallic materials and components comply with BS6920 at 60°C
Range of shower outlets and shower handsets with plastic bodies (various finishes) and multi-spray patterns depending on model. Maximum operating temperature 50°C.
Range of wall mounted overhead shower outlets, (chrome or gold plated brass bodies).
Non-metallic materials and components comply with BS6920 at 85°C
Range of shower handsets, (plastic bodies – various finishes) incorporating a plastic flow regulator in the inlets.
Non-metallic materials and components comply with BS6920 at 65°C
Range of multi-function overhead shower outlets, (plastic bodies – various finishes). The inlets incorporate plastic flow restrictors and stainless-steel strainer washers.
Non-metallic materials and components comply with BS6920 at 65°C
Page 45 of 82
We use cookies to give you the best possible experience with WRAS. Some are essential to provide website functions and ensure the website is secure. We also use cookies to help us understand how people use the site and to make improvements. Click "Accept All" to enable recommended settings or click "Manage cookies" to adjust your settings. For more details, see our Cookie Policy.