Air Source Hot Water Cylinder range of cased and insulated, unvented hot water storage cylinders (enamelled steel) of the package type incorporating heat pump module. The DHW circuit includes a factory fitted temperature & pressure relief valve (Caleffi) set at 7 bar and 95˚C . The safety kit incorporates a pressure reducing valve (Caleffi) set at 3.5 bar, strainer, check valve cartridge, verified by test (suitable for backflow protection against Fluid Category 2 and an expansion valve (Caleffi) set at 6 bar, expansion vessel (Reflex) and a tundish (Caleffi). The temperature of the hot water is controlled by a factory fitted manual control (set at 60˚C) and a high pressure switch positioned on the heat pump module (maximum temperature 65˚C) The cylinders are factory fitted with standard dual control immersion heater. Immersion heater incorporate control and manual resetting thermostats (maximum 89˚C). Maximum working pressure 5.5 Bar Maximum operating temperature 75°C. Maximum supply pressure to the pressure reducing valve is 12 bar. Maximum working pressure of the primary circuit 3.5 bar. Maximum operating temperature 80°C.
Page of 1
We use cookies to give you the best possible experience with WRAS. Some are essential to provide website functions and ensure the website is secure. We also use cookies to help us understand how people use the site and to make improvements. Click "Accept All" to enable recommended settings or click "Manage cookies" to adjust your settings. For more details, see our Cookie Policy.