Range of single hole, single outlet (swivel) combination tap assemblies with brass bodies (various finishes), incorporating a quarter turn ceramic disc headworks with single leaver operating members. The spout outlet incorporates a plastic aerator. Maximum working pressure 5.5 bar. Maximum operating temperature 60°C.
Range of single hole, single outlet (swivel) combination tap assemblies with brass bodies (various finishes), incorporating a ceramic cartridge or quarter turn ceramic disc headworks (see model) with single lever operating members. The spout outlet incorporates a flow straightener or optional aerator. Maximum working pressure 5.0 bar. Maximum operating temperature 65°C.
Range of floor mounted single hole, single outlet (swivel), combination tap assembly (chromium plated brass), incorporating a ceramic cartridge headwork with a single lever operating member and a manual diverter to shower outlet. The spout outlet incorporates a plastic aerator. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.
Range of two hole, single outlet, (fixed) combination tap assemblies (chromium plated brass), incorporates a quarter turn ceramic disc headwork with single lever operating members. The spout outlets incorporate a plastic flow straightener and the products are supplied with metal backnuts. . Maximum working pressure 10.0 bar. Maximum operating temperature 85°C.
Wall mounted, concealed, two-hole, single outlet fixed combination tap assembly (chrome plated brass) body incorporating a ceramic cartridge head work with a single lever operating member. The spout outlet incorporates a plastic aerator. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.
Wall mounted, concealed two-hole, single outlet fixed combination tap assembly (chrome plated brass) body incorporating a ceramic cartridge headwork with a single lever operating member. The spout outlet incorporates a plastic flow straightener. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.
Range of two hole, single outlet, (fixed) combination tap assemblies (chromium plated brass), incorporating a quarter turn ceramic disc headwork with single lever operating members. The spout outlets incorporate a plastic flow straightener and the products are supplied with metal backnuts. Maximum working pressure 10.0 bar. Maximum operating temperature 85°C.
Range of two hole, single outlet, (fixed) combination tap assemblies (chromium plated brass), With a quarter turn ceramic disc headwork with single lever operating members. Models M4306, M4306E & M4306F incorporate a non rising spindle headwork with dome type operating members. Model M4306G incorporate a non rising spindle headwork with cross top operating members. The spout outlets incorporate a plastic flow straightener and the products are supplied with metal backnuts. . Maximum working pressure 10.0 bar. Maximum operating temperature 85°C.
Range of wall mounted two-hole, metal, single outlet (fixed) combination tap assemblies (chromium plated brass), incorporating a ceramic disc diverter headwork controlling the flow between the spout outlet and the shower outlet with a dome type operating member. Temperature is controlled independently via a thermostatic cartridge with dome type operating members that incorporates a manual override button. The spout outlet incorporates a plastic aerator. Each inlet incorporates a stainless-steel strainer and an approved check valve cartridge, however, the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum working pressure 10.0 Bar Maximum operating temperature 60°C
Range of deck mounted, two hole, single outlet (fixed) combination tap assemblies with brass bodies (chrome plated). Incorporating quarter turn ceramic disc headworks, dome type operating members and self cancelling diverter to shower outlet. The temperature is controlled independently via a thermostatic cartridge with a dome type operating member that also incorporates a manual override button. Both inlets incorporate approved check valve cartridges, however, the complete product has not been fully tested to demonstrate it provides backflow protection. The spout outlet incorporates a plastic aerator. Models TL30024CP and TR30024CP are supplied with a shower riser rail, shower hose and shower handset. Maximum working pressure 5.0bar. Maximum operating temperature 60°C.
Two-hole, single outlet swivel combination tap assembly in various finishes (see model) incorporating quarter turn ceramic disc headworks with a cross top operating members. The spout outlet incorporates a plastic aerator. Supplied with a pop-up waste. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.

Range of two-hole, single outlet (fixed) combination tap assemblies (chromium plated brass), incorporating quarter turn ceramic disc headwork with single lever operating members and a lockable manual diverter to shower outlet. The spout outlet incorporates a plastic flow straightener. The product is supplied with hose, handset and metal backnuts. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.
Deck mounted two hole, single outlet (fixed) combination tap assembly (chromium plated brass), incorporating quarter turn ceramic disc headworks with single lever operating members and a lockable self- cancelling diverter to the shower outlet. Temperature is controlled independently via a thermostatic cartridge with a dome type operating member that incorporates a manual override button. Both inlets incorporate stainless-steel strainers and a single check valve cartridge (however, the complete product has not been fully tested to demonstrate it provides backflow protection). The spout outlet incorporates a plastic flow straightener and a stainless steel mesh Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.
A range of three hole, single outlet (fixed) combination tap assemblies with brass bodies (chromium plated), incorporating quarter turn ceramic disc headworks and various operating members (see models). The side valves and the spout are connection via stainless steel braided EDPM lined flexible hose assemblies incorporating ½” BSP captive nut end connections. Inlet to the main body incorporates a flow regulator. The products are supplied with metal back nuts and pop-up wastes. Maximum working pressure 5.5 bar. Maximum working temperature 60°C.
Range of three-hole, single outlet (fixed) combination tap assemblies (chrome plated brass). Incorporating a quarter turn ceramic disc headwork, and dome type operating members (model RAKPER3011C) or cubed type operating members (model RAKPES3011C). Supplied with stainless steel braided EPDM lined hoses, intended for connection between the valves and the spout assembly The spout outlet incorporates a plastic aerator. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.
Range of wall mounted three-hole, single outlet (fixed) combination tap assemblies with brass bodies (various finishes) incorporating a quarter turn ceramic disc headwork with various operating members (see model). The spout outlets incorporate a plastic flow straightener (models GEO-109-C/P & GEO-109/220/CP) or a plastic aerator (all other models) Maximum working pressure 5.0 bar. Maximum operating temperature 65°C.

Range of three hole, single outlet (fixed) combination tap assemblies, brass bodies (various finishes) incorporating quarter turn ceramic disc headworks with various styles of operating members. The spout outlet incorporates a plastic aerator and is connected to the headworks via stainless steel braided EPDM lined hose assemblies. The product is supplied with either a lever type pop up (HIRONDELLE models) or click type waste (ICON-X & CORVAIR models). Maximum working pressure 3.5 Bar. Maximum operating temperature 60°C.
Range of wall mounted spout outlets with either stainless steel or brass bodies (various finishes - see model), incorporating a plastic aerator and EPDM ‘O’-rings. Maximum working temperature 60°C.
Range of spout outlets (chromium plated) brass bodies. Model 13 800 782 incorporates a plastic aerator. Maximum operating temperature 60°C
Range of wall mounted spout outlets with a chromium plated brass bodies and NBR ‘O’-rings. The outlets incorporate a plastic aerator. Maximum operating temperature 85°C.
Range of dosing pumps with plastic bodies. Models PM004 & PM005 have a maximum operating pressure of 6.0 bar. All other models have a maximum operating pressure of 10.0 bar. Cold water use only.
Filling loop assemblies comprising of a stainless steel braided, EPDM lined hose, double check valve assembly with isolation valve verified by test (suitable for backflow protection against fluid category 3) and either a straight or tee isolation valve. Maximum working pressure 10.0 bar. Maximum operating temperature 85ºC.
Filling link assembly with a nylon body and EPDM ‘O’-rings. The product incorporates a screwdriver operated shut off valve and two check valve cartridges, verified by test (suitable for backflow protection against Fluid Category 3). The product is also supplied with two screwdriver operated angled spherical valves and a mounting bracket. Maximum working pressure 10.0 bar. Cold water use only.
Filling loop assemblies comprising of a stainless steel braided, EPDM lined hose, double check valve assembly with isolation valve verified by test (suitable for backflow protection against fluid category 3) and either a straight or tee isolation valve. Maximum working pressure 10.0 bar. Maximum operating temperature 85ºC.
Uponor Uni Pipe PLUS system incorporating Uponor RTM metal and PPSU fittings for use with Uni Pipe PLUS PE-RT/AL/PE-RT pipes. Maximum operating pressure 10.0 bat at 70°C.
Pexal range of brass press fittings with EPDM ‘O’-rings for use with copper pipe EN1057. Model VS0171373 incorporates 90° copper elbow (chrome plated) Maximum working pressure 10.0 bar. Maximum operating temperature 95°C.
>B< Press range of stainless-steel SUS316L fittings for use with 316L stainless steel tube manufactured to EN10312. For above and below ground use. Maximum working pressure 16.0 bar. Maximum operating temperature 85°C.
Center Brand range of brass and copper end feed fittings for use with copper pipe. For above ground use only. Maximum working pressure 16.0 bar. Maximum operating temperature 99°C.
Single low-level horizontal mount float switch with stainless-steel body and float. Maximum operating temperature 100°C.
Range of dual flush, WC outlet valves. CJ305 is operated via a push button assembly or with battery powered infra red sensor. CJ302 is controlled with a push button assembly for either full or reduced flush and both models incorporate an internal overflow. Cold water use only.
Electric instantaneous, vented mains water heater with plastic a housing and silicon rubber hose. Maximum operating temperature 98°C.
"Greenstar" range of indirect heat interface units and "Flow 8000" (added December 2024) range of direct heat interface units providing heating and instantaneous hot water. The heating system incorporates an expansion vessel. The products are sold with or without a prefix kit (see model), which comprises of a mounting bracket that includes spherical valves for all circuits. The "Greenstar" indirect models include a pressure relief valve (set at 3.0 bar) on the space (central) heating circuit. Greenstar models: Maximum working pressure district heating 10.0 bar. Maximum working pressure space heating 2.5 bar. Maximum working pressure secondary hot water 10.0 bar. Maximum operating temperature 60°C (secondary) and 90°C (primary). Flow 8000 models (added December 2024): Maximum working pressure district and space heating 10.0 bar. Maximum working pressure secondary hot water 10.0 bar. Maximum operating temperature 60°C (secondary) and 90°C (primary).
Water meter with a DZR brass body, stainless steel temperature sensors and EPDM ‘O’-rings. The inlet incorporates a plastic strainer. Maximum working pressure 16.0 bar. Maximum operating temperature 85°C.
‘RSM’ range of ultrasonic water meters with blue epoxy coated ductile iron bodies, stainless steel transducer and EPDM ‘O’-rings. Maximum working pressure 16.0 bar. Maximum operating temperature 50°C.
(Jet) range of water meters with either ductile iron (171259 & 171279 models) or brass (all other models) blue epoxy coated bodies and EPDM rubber ‘O’-rings. Maximum working pressure 16.0 bar. Maximum operating temperature 85°C.
Range of water meters with blue epoxy coated iron bodies and EPDM ‘O’-rings. Maximum working pressure 16.0 bar. Maximum operating temperature 85°C.
Range of water meter manifolds with gun metal bodies and ball valve with either a quarter turn stop valve or screw down stop valve. The products incorporate an approved check valve cartridge however, the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum working pressure 16.0 bar. Cold water use only.
Range of concealed thermostatic mixing valves with DZR brass bodies incorporating a thermostatic cartridge controlling the temperature. The inlets incorporate asingle check valve cartridges, however, the complete product has not been fully tested to demonstrate it provides backflow protection Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.
Range of spout outlets with brass bodies (various finishes) incorporating an aerator. Product is supplied with either a lever type pop up (HIRONDELLE models) or click type waste (ICON-X & CORVAIR models). Maximum working pressure 3.5 bar. Maximum operating temperature 60°C.
Spout end flow control device (aerator with ‘switchable’ spray formation). Maximum operating temperature 65°C.
Range of vertical multistage pumps with stainless-steel bodies, stainless-steel impellers, shaft and outer sleeve. Maximum working pressures: T (oval flange): 16.0 bar. V (Victaullic & grooved), C (clamp flanges) & F (round flange) versions: 26.0 bar. Maximum operating temperature 100°C.
Range of multistage pumps with brass suction and discharge bodies, stainless steel housing, shaft and impeller, and EPDM ‘O’-rings and seals. Maximum working pressure: 6.0 bar (41491 & 41492 models) or 9.0 bar (41493 & 41494 models). Maximum operating temperature 65°C.
Range of shower outlets incorporating brass bodies (various finishes) and NBR ‘O’-rings. Maximum operating temperature 85°C.
Shower outlet incorporating brass body (gold effect finish), incorporating a flow regulator and EPDM O-rings. Maximum operating temperature 60ºC.
Shower head with a brass body (various finishes), incorporating EPDM O- rings and a stainless-steel strainer at the inlet. Maximum operating temperature 60.0°C
Shower handset incorporating a chrome plated plastic body and EPDM ‘O’-rings. Maximum operating temperature 60°C.
Ranges of overhead shower outlets with brass bodies, chrome plated plastic shower handsets, shower sets and shower kits. The shower sets comprise of a chrome plated plastic shower handset and shower hose. The shower kits comprise of a chrome plated plastic shower handset, brass wall elbow and either stainless steel interlocked, or PVC coated, shower hoses. The inlets of the shower handsets incorporate a plastic flow regulator at the inlet. Shower kits with ½” (M) inlets are also supplied with a brass wall elbow which incorporate a plastic flow regulator and an approved single check valve cartridge (however, the complete product has not been fully tested to demonstrate it provides backflow protection). Maximum operating temperature 60°C.
Range of Y type strainers with blue epoxy coated ductile iron bodies and EPDM ‘O’-rings. Maximum working pressure 25.0 bar. Maximum operating temperature 85°C
Range of wall mounted hose union taps (brass body or DZR brass body - see model) incorporating a non-rising spindle headwork with a ‘T’-type operating member. The 1BCB001 & 1BCB701 models incorporate two approved single check valve cartridges, however the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum working pressure 14.0 Bar. Maximum operating temperature 85°C.
Deck mounted laboratory tap, grey powder coated brass body, with three outlets: two are fixed, one is a swivel spout. Each outlet has its own individual quarter turn ceramic disc headwork controlling the flow with a dome type operating member, and a hose union attachment. The product is supplied with a brass backnut. Maximum working pressure 6.0 bar. Maximum operating temperature 85°C.
Page 27 of 209
We use cookies to give you the best possible experience with WRAS. Some are essential to provide website functions and ensure the website is secure. We also use cookies to help us understand how people use the site and to make improvements. Click "Accept All" to enable recommended settings or click "Manage cookies" to adjust your settings. For more details, see our Cookie Policy.