Range of angled valves with brass bodies (some models chrome plated). Maximum working pressure 10 bar. Maximum operating temperature 65°C
‘Satefy group’ with a brass inlet and a DZR brass body which incorporates a lever operated spherical valve, followed by an approved check valve cartridge, verified by test (suitable for backflow protection against Fluid Category 2) and a plastic bodied pressure relief valve (set at 6.0 bar). The product incorporates a test point. The compression connections are for use copper pipe (manufactured to EN 1057). Maximum working pressure 16.0 bar. Maximum operating temperature 85°C.
Range of motorised position pilot operated control valves with epoxy coated ductile iron bodies and stainless-steel pipework and fittings. Maximum operating pressure 16.0 bar. Maximum operating temperature 65°C.
Range of ultraviolet disinfection units with stainless-steel bodies. Maximum working pressure 10.0 bar. Maximum operating temperature 40°C.
Range of UV disinfection units with stainless steel bodies. Maximum working pressure 10.3 bar. Maximum operating temperature 60°C.
'Loctite PC 7255 GN (Green) coating for use with Bonderite M-NT 1455-W primer'. Factory applied, green coloured, two-component epoxy resin coating. Prime the surface to be coated with the Bonderite primer wipe. Mix and apply as per manufacturer’s TDS dated October 2016. Cure for 7 days@23°C. For use with water up to 85°C. This material is only approved for the curing conditions that appear on the approval. If the cure conditions are varied from those specified on the approval then the material is not covered by the scope of the approval.
'Edelpoxy FN TM 142'. Factory coloured, red coloured epoxy resin coating consisting of a base and hardener. Mix base and hardener in a 3:1 volume ratio and apply as per manufacturer's IFU 'PCC/ PC 142', dated '10.07.2018'. Cure for 7 days@30°C. For use with water up to 60°C. This material is only approved for the mixing and curing conditions that appear on the approval. If the mixing and/or curing conditions are varied from those specified on the approval then the material is not covered by the scope of the approval.
'LMI.Hygienic HI-Build Epoxy'. Factory applied, two- component, blue coloured epoxy coating. Mix base and hardener in a weight ratio of 100:15 and apply as per manufacturer's instructions 'LMIEP1403032', dated '22/06/2024'. Cure for 2 hours@20°C. For use with water up to 23°C. This material is only approved for the mixing & curing conditions that appear on the approval. If the mix and/or cure conditions are varied from those specified on the approval then the material is not covered by the scope of the approval.
‘Corroless ACO Brush Grades RAL5005 (GB861) and Light Green (GB206)’ (formerly known as 'Acothane Brush Grades Blue & Green'). Site applied, blue or green coloured, two-part polyurethane coatings consisting of an amber coloured, liquid activator and blue or green coloured coating. Mix brush grade and activator in a 3.24:1 weight ratio. Apply as per technical data sheet dated Feb 2020. Cure for 14 days@7°C. For use with water up to 23°C. This material is only approved for the mixing and curing conditions that appear on the approval. If the mix and cure conditions are varied from those specified on the approval then the material is not covered by the scope of the approval.
'Interline 975 White'. Site applied, two-part epoxy coating which can be applied as one coat or three coats. Mix parts A & B in a 2.2:1 and apply as per manufacturer's TDS 'Ref:4236', 'Issue Date: 04/02/2015'. When applied as a single coat, the coating must be cured for 14 days at 10°C. When applied as a three-coat system, the coating must be cured as follows: coat 1 = 24 hours@10 °C, coat 2 = 24 hours@10 °C & coat 3 = 14 days@10 °C. For use with water up to 23°C. This material is only approved for the mixing and curing conditions that appear on the approval. If the mixing and/or curing conditions are varied from those specified on the approval then the material is not covered by the scope of the approval.
'ULTRADUR® B4300 G6 FC AQUA WHITE 25262 & ULTRADUR® B4300 G6 FC AQUA BLACK 15142'. White coloured & black coloured, injection moulded PBT materials. For use with water up to 85°C.
'662016, 662014, 662062 & 662061'. White coloured, PTFE tape manufactured by calendering. For use with water up to 85°C.
'RIAMAXX HR GF40 Xgea14 KTW schwarz'. Black coloured, injection moulded Polyketone material. For use with water up to 85°C.
Range of bottom and side entry BS1212-4 (2016) compact type float operated valves for WC flushing cisterns, delayed or non-delayed fill. The inlet incorporates a strainer. Maximum working pressure - 10 Bar Cold water use only.
Concealed WC dual flushing cistern with a side entry BS 1212-4 (2016) float operated inlet valve providing a Type AG air gap arrangement and a dual flush outlet valve. The flush volume is operated by a two-push button assembly for a 6 or 3 litre flush volume. The cistern is operated by a manual push button and incorporates a servicing valve and flexible hose on the inlet supply. Maximum working pressure – 10.0 bar, cold water use only.
Range of concealed WC flushing cisterns incorporating a side entry compact type float operated inlet valve providing a Type AG air gap with a dual flush drop valve for full flush volumes of up to 6 litres and a reduced flush of up to 4 litres. The cistern is operated by a manual push button and incorporates a servicing valve and flexible hose on the inlet supply. Maximum working pressure 10.0 bar. Cold water use only.
WC flushing cistern incorporating a side entry compact type float operated inlet valve providing a Type AG air gap with a dual flush drop valve for full flush volumes of up to 6 litres and a reduced flush of up to 4 litres. The cistern is operated by a manual push button and incorporates a servicing valve on the inlet supply. Maximum working pressure 10.0 bar. Cold water use only.
Range of single hole, single outlet (swivel) combination tap assemblies with brass bodies (various finishes), incorporating ceramic cartridge headworks and single lever operating members. The spout outlet incorporates a pull-down spray with a plastic aerator. Maximum working pressure 10.0 bar. Maximum operating temperature 65°C.
Range of deck mounted, single-holed, single outlet (fixed) combination tap assemblies (brass bodies – various finishes) incorporating ceramic cartridge headworks with single lever operating members. The spout outlets incorporate plastic aerators. Models (TVW105002000xx, TVW105003000xx, TVW105101110xx & TVW105141110xx) are supplied with lever operated pop-up wastes (not verified by test) Model TVW105105110xx) is supplied with a click type pop-up waste (verified by test). Maximum working pressure 10.0 Bar. Maximum operating temperature 60°C.
Single hole, single outlet, fixed combination tap assemblies (brass bodies - various finishes), incorporating a ceramic cartridge headwork with a single lever operating member. The spout outlet incorporates a plastic flow straightener and an optional flow regulator. Maximum working pressure 10.0 Bar. Maximum operating temperature 85°C.
Single hole, single outlet (swivel) combination tap assembly (brass body - various finishes), incorporating ceramic cartridge headworks with a single lever operating member. The spout outlet incorporates a plastic flow straightener or plastic aerator. Maximum working pressure 10.0 Bar Maximum operating temperature 65.0°C
Range of single hole, single outlet, swivel, combination tap assemblies in various finishes. The models incorporate a ceramic cartridge headwork and a single lever operating member. The spout outlets incorporate a plastic flow straightener. Maximum working pressure 5.0 bar.
Non-metallic materials and components comply with BS6920 at 65°C
Single hole, single outlet (swivel) combination tap assemblies (brass bodies - various finishes), incorporating a ceramic cartridge headwork with a single lever operating member. The spout outlet incorporates a plastic aerator. Maximum working pressure 10.0 Bar Maximum operating temperature 65.0°C
Range of wall mounted, two-hole, single outlet, (fixed), combination tap assemblies, (brass bodies – various finishes), incorporating a ceramic cartridge headworks with single lever operating members. The spout outlets incorporate plastic aerators. Maximum operating pressure 10 bar. Maximum operating temperature 60°C 13 623 180 rough-in set does not form as part of this approval.
Range of wall mounted, two hole, single outlet fixed combination tap assemblies (chromium plated brass), incorporating a single sequential thermostatic cartridge controlling both flow and temperature with a single lever operating member. The spout outlets incorporate a plastic flow straightener The inlets incorporate a concentric isolation valve, stainless steel strainer and a plastic flow regulator. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C
Range of wall mounted, two-hole, single outlet (fixed) combination tap assemblies, (brass bodies - various finishes), incorporating a ceramic cartridge headwork with single lever operating members and a manual diverter to shower outlet. The spout outlet incorporates a plastic aerator. Both inlets incorporate stainless steel strainers and approved check valve cartridges however, the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum working pressure 10.0 Bar Maximum operating temperature 60.0°C
Range of Wall mounted, four-hole, single outlet (swivel) combination tap assemblies (Various Finishes). Incorporating a ceramic cartridge headwork controlling the flow to the shower handset and two quarter turn ceramic disc headworks controlling the flow to the spout outlet, all with single lever operating members. The spout outlets incorporate a plastic aerator. The inlet to the shower handsets incorporate an approved check valve cartridge, however, the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum working pressure 10.0 Bar Maximum operating temperature 60.0°C
Range of wall mounted or floor standing spout outlets (fixed or swivel - see model in various finishes). All models incorporate a plastic flow straightener, except for the 93-Floor Mounted Bath Filler which has a plastic aerator.
Non-metallic materials and components comply with BS6920 at 60°C
Range of deck mounted spout outlets (fixed or swivel - see model, Various finishes) incorporating a plastic flow straightener. The products are supplied with metal backnuts.
Non-metallic materials and components comply with BS6920 at 60°C
Range of Stainless-Steel pipes and fittings. Models OT 100 are manufactured to EN 10217-7, all other models are manufactured to EN 10253-4. Fittings and pipe are connected via welding. Maximum working pressure; OT 100 DN15 - DN 200 25 Bar, DN200 – DN350 16 Bar OT 110 DN15 - DN 200 25 Bar, DN200 – DN350 16 Bar OT 200 DN15 - DN 200 25 Bar, DN200 – DN350 16 Bar OT 201 DN15 - DN 200 25 Bar, DN200 – DN350 16 Bar OT 212 DN15 - DN 200 25 Bar, DN200 – DN350 16 Bar OT 213 DN15 - DN 200 25 Bar, DN200 – DN350 16 Bar OT 214 DN15 - DN 200 25 Bar, DN200 – DN350 16 Bar OT 400 DN15 - DN 200 25 Bar, DN200 – DN350 16 Bar OT 401 DN15 - DN 200 25 Bar, DN200 – DN350 16 Bar OT 410 DN15 - DN 200 25 Bar, DN200 – DN350 16 Bar OT 411 DN15 - DN 200 25 Bar, DN200 – DN350 16 Bar Type 37 DN15 – DN125 16 Bar, DN150 10 Bar Type 37M DN15 – DN80 16 Bar, DN100 10 Bar Maximum operating temperature – 99°C.
Range of PFD press copper crimp fittings with EPDM ‘O’-rings for use with copper tube manufactured to EN 1057. The joints are achieved by means of a crimping tool. For above ground use. Maximum working pressure: 16.0 bar. Maximum operating temperature: 85°C
Range of “JRG Sanipex MT” compression fittings with EPDM ‘O’-rings for use with “JRG Sanipex MT ECO” multilayer pipes (PE-RT II/Al/PE-RT II). Maximum working pressure 10.0 bar. Maximum operating temperature 70°C.
‘ZL’ range of U profile press fittings (nickel plated brass bodies) for use with ‘ZL’ range of PERT/AL/PERT multi-layered pipes. Maximum working pressure 10.0 bar. Maximum operating temperature 95°C.
TP range of capillary solder ring copper fittings for use with copper tube EN1057, for above ground use only. Maximum working pressure: 25.0 bar. Maximum operating temperature: 85°C.
Range of plastic compression fittings incorporating polypropylene bodies& plastic pipe liners.. For use with both PE80 & PE100 pipe manufactured to BS EN 12201. Maximum working pressure 16 Bar Maximum operating temperature 23°C
Range of press fittings with a stainless steel body and EPDM ‘O’ rings for use with stainless steel 316L pipe manufactured to EN10312. For above ground use only. Maximum working pressure 16.0 bar. Maximum operating temperature 85°C.
‘Tectite 316’ range of push-fit fittings with stainless steel bodies incorporating EPDM ‘O’-rings for use with stainless steel tube (Grade 316 manufactured to EN 10312). Maximum working pressure: Fittings 15mm to 28mm 10.0 bar. Fittings 35mm to 54mm 6.0 bar. Maximum operating temperature 90°C.
Range of compression fitting with brass and DZR brass bodies, supplied with brass compression rings. For use with copper tube (manufactured to BS EN1057). Maximum working pressure 16.0 bar. Maximum operating temperature 85°C.
Range of copper crimped fittings with EPDM ‘O’-rings for use with copper pipe manufactured to EN1057. For above and below ground use. Maximum working pressure 16 Bar. Maximum operating temperature 99°C.
B Profile range of 316L & 304 stainless steel press fittings with EPDM ‘O’-rings for use with stainless steel pipe manufactured to EN 10312, for both above and underground use. Joints are achieved by the use of a press fitting tool. Maximum working pressure 16.0 Bar. Maximum operating temperature 85°C.
Range of R-154 stainless steel pressed collars incorporating stainless steel bodies (304L or 316L) and are only to be used with stainless steel pipe. Maximum working pressure for sizes up to DN150 (FCM models) or DN125 (FCI models) is 25.0 bar. Maximum working pressure for size DN200 (FCM models) or DN150 and DN200 (FCI models) is 16.0 bar. Maximum operating temperature 99°C.
Range of wall mounted gas fired condensing instantaneous water heaters. Maximum working pressure 10.0bar. Maximum operating temperature 85°C.
‘PREMIX’ range of wall hung, gas-fired condensing combination boilers providing domestic hot water via a plate heat exchanger. The pressurised central heating system incorporates an expansion vessel and pressure relief valve set at 3.0 bar. The supplies to both the domestic hot water and primary circuit are controlled via spherical valves. Maximum working pressures: Primary circuit: 2.5 bar, Secondary circuit 10.0 bar. Maximum operating temperature both circuits: 80°C.
Water hammer arrestor with brass body and EPDM ‘O’ ring. Maximum working pressure 10.0 bar. Maximum operating temperature 90°C.
Water hammer arrestor with brass body and EPDM ‘O’ ring. Maximum working pressure 10.0 bar. Maximum operating temperature 90°C.
Range of click type pop-up wastes (brass or plastic bodies - various finishes, see model).
Range of single or twin booster pumps with stainless steel bodies and stainless-steel impellers. Maximum working pressure 8.0 Bar Maximum operating temperature 90.0°C
Range of single or twin shower pumps with brass bodies, brass impeller supplied with flexible connection hoses that incorporate servicing valves. Maximum Working pressure 6 Bar Maximum operating temperature 65°C
Range of single stage booster pumps incorporating a flow switch. Model 46349 CH 12-14 B is supplied with a pressure vessel and incorporates an approved check valve cartridge; however, the complete product has not been fully tested to demonstrate it provides backflow protection. Supplied with a strainer and stainless-steel braided EPDM lined flexible connection hoses. Maximum working pressure 6.0 bar. Maximum operating temperature 65°C.
Range of overhead shower outlets with (brass bodies – various finishes) incorporating stainless-steel filter washers at the inlet. Maximum operating temperature 85°C.
Page 19 of 24
We use cookies to give you the best possible experience with WRAS. Some are essential to provide website functions and ensure the website is secure. We also use cookies to help us understand how people use the site and to make improvements. Click "Accept All" to enable recommended settings or click "Manage cookies" to adjust your settings. For more details, see our Cookie Policy.