Range of two hole, single outlet (fixed) combination tap assemblies with brass bodies (various finishes - see model), incorporating quarter turn ceramic disc headworks with single lever operating members and a locakble self-cancelling diverter to shower outlet. The spout outlets incorporate a plastic aerator. The product is supplied with a shower hose and handset and metal backnuts Maximum working pressure 5.0 bar. Maximum working temperature 60°C.
Range of wall mounted three hole, single outlet (fixed) combination tap assemblies with brass bodies (in various finishes). Incorporating quarter turn ceramic disc headworks and various operating members. The spout outlet incorporates a plastic aerator. Maximum working pressure 3.5 bar. Maximum operating temperature 60°C.
Range of three hole, single outlet (fixed) combination tap assemblies with brass bodies (various finishes - see model), incorporating quarter turn ceramic disc headworks with various operating members (see model). The products are supplied with stainless steel braided EDPM lined flexible hose assemblies incorporating ¾” captive nut end connections for installation between the headworks and the spout. The spout outlet incorporates either a plastic flow straightener or plastic aerator (see model). The invincible range is supplied with a plastic back nut, all other models are supplied with metal back nuts. Maximum working pressure 3.0 bar. Maximum working temperature 60°C.
Three hole, single outlet (fixed) combination tap assembly with a brass body (various finishes - see model), incorporating quarter turn ceramic disc headworks with dome type operating members. The products are supplied with stainless steel braided EDPM lined flexible hose assemblies incorporating ¾” captive nut end connections for installation between the headworks and the spout. The spout outlet incorporates a plastic aerator. The product is supplied with metal back nuts. Maximum working pressure 3.0 bar. Maximum working temperature 60°C.
Range of three-hole, single outlet (swivel) combination tap assembly (chromium plated brass), incorporating quarter turn ceramic disc headworks with single lever (20815882 model) or cross top (20815892 model) operating members. The product is supplied with stainless steel braided PEX lined flexible hose assemblies for installation between the side valves and the spout. The spout outlets incorporate a plastic aerator. The side valves are supplied with plastic backnuts. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.
Three hole, wall mounted, concealed basin mixer with a brass body (chrome plated) consisting of a rough in set 45089 and extermnal trim 46090. Incorproating a quarter turn ceramic disc headworks and single lever operating members.The spout outlet incorporates a plastic aerator. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.
Bath spout outlet with a brass body (various finishes) and a plastic aerator. Maximum operating temperature 60°C.
Range of deck mounted spout outlets (chrome plated brass). The spout incorporates a plastic flow regulator on the inlet and a plastic aerator on the outlet. Maximum working temperature 60°C.
Range of expansion vessels incorporating composite plastic bodies and butyl diaphragms. Maximum working pressure 8.6 bar. Cold water use only.
Filling link assembly, incorporating a sliding manifold with EPDM ‘O’-rings, isolation valves and an isolation valve with a double check valve assembly (verified by test as suitable for backflow protection against Fluid Category 3). Maximum working pressure 10.0 bar. Cold water use only.

Water filter with polypropylene body. Maximum working pressure 8.6 bar. Cold water use only.
Range of brass compression fittings for use with copper pipe IS EN 1057. Maximum working pressure 10.0 bar. Maximum operating temperature 99°C.




Range of press fittings incorporating brass or PVDF bodies and EPDM ‘O’-rings. For use with Henco standard PE-Xc/AL/PE-Xc pipe. Maximum working pressure 10.0 bar. Maximum operating temperature 95°C.
Range of press fittings incorporating stainless steel bodies and EPDM ‘O’-rings. Maximum working pressure 16.0 bar. Maximum operating temperature 85°C.
Range of SUS316L & SUS304 stainless steel press fittings for use with stainless steel pipe manufactured to EN 10312. Maximum working pressure 16.0 bar. Maximum operating temperature 85°C.
Range of press fit fittings incorporating copper (GP5 models) or bronze (GP4 models) bodies and EPDM `O`-rings, for use with copper tube to EN 1057. For above ground use only. Maximum working pressure 16.0 bar. Maximum operating temperature 85°C.
Range of WC dual flush drop valves comprising of a plastic body, silicone seal and an internal overflow. The valve is operated via a push button or lever assembly for either full or reduced flush. Cold water use only.
Range of wastewater heat recovery systems incorporating a double wall stainless steel corrugated pipe. Maximum working pressure 16.0 bar. Cold water use only.
Range of wastewater heat recovery systems incorporating stainless steel corrugated pipe. Maximum working pressure 16.0 bar. Cold water use only.
Range of vertical vented cased copper cylinders with indirect coils. The secondary circuit incorporates a thermostatic mixing valve. The inlet consists of a ball valve with strainer, inline non verifiable single check valve and mini shock arrestor. Cylinder are supplied with a factory fitted immersion heater. Maximum working pressure - secondary 6.0 bar, primary 2.2 bar. Maximum operating temperature - secondary is 60°C, primary 85°C
‘E-WATER BLOCK’ self-closing valves with black plastic bodies and stainless-steel filters. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.
Appliance inlet group assembly comprising of EPDM gaskets, a plastic bodied Y-pattern strainer, ¾” BSP (F) x ½” BSP (F) brass adaptor, a chrome plated DZR brass bodied double check valve assembly (suitable for backflow protection against Fluid Categry3), a ½” BSP (F) x ¾” BSP (M) brass adaptor, a dual layer hose with a PVC outer (grey) and PVC liner (black), a solenoid valve which incorporates a plastic strainer and a flow regulator within the inlet. Maximum working pressure 6.0 bar. Maximum operating temperature 60°C.
Range of water meter couplings with black plastic bodies. Maximum working pressure 16.0 bar. Cold water use only
Range of booster pumps with stainless steel bodies and impellers (AISI 304: AL-RED models or AISI 316: CP models), EPDM ‘O’-rings and a ceramic/graphite/EPDM shaft seal. Maximum working pressure: CP(m) 100-130-132-150-158 and AL-RED(m) 600-610-620 models: 6.0 bar. All other models: 8.0 bar. Maximum operating temperature 90°C.
Range of shower heads and a shower handset. The shower heads have a stainless steel body and ball joint, silicon ‘O’-rings and nozzles, and the inlet incorporates a combined NBR washer and stainless steel filter. The shower handset has a stainless steel body, NBR ‘O’-rings and silicon nozzles. All products incorporate a plastic flow regulator on the inlet. Maximum operating temperature 60°C.
Range of wall mounted or ceiling mounted shower arms with brass bodies (various finishes) Maximum operating temperature 90°C.
Handshower with a chrome plated plastic body. The inlet incorporates a single check valve cartridge, however, the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum operating temperature 60°C.
Range of wall or ceiling mounted shower arms and a wall mounted shower outlet + holder. The products incorporate a stainless steel bodies (various finishes). Maximum operating temperature 60°C.
Dolphin Blue Flexi hose range of wall outlets and brackets incorporating stainless steel bodies (various finishes) and EPDM ‘O’-rings. Maximum operating temperature 85°C
Dolphin Blue range of handheld shower outlets with a stainless bodies (various finishes) and EPDM ‘O’-rings. The inlet incorporates a single check valve cartridge however, the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum operating temperature 85°C
Range of wall mounted shower elbows with brass bodies (chrome plated) incorporating single check valves cartridges fitted on the outlet (however, the complete product has not been fully tested to demonstrate it provides backflow protection).Maximum operating temperature 65°C.
Range of shower outlets with brass or stainless steel bodies (chrome plated) fitted with NBR ’O’-rings. Maximum operating temperature 65°C.
Range of shower arms with a brass body and various finishes. Maximum operating temperature 60°C.
Range of shower handsets with plastic bodies and EPDM ‘O’-rings. Maximum operating temperature 65°C.
Range of wall mounted compact shower panels with push button timed flow control. The inlet incorporates a plastic flow regulator and a stainless-steel strainer. Maximum working pressure 4.0 Bar Maximum operating temperature 60°C
Concealed installation set for use with wall mounted overhead shower outlets (brass body – various finishes). The inlet to the shower outlet incorporates a stainless-steel strainer, a plastic flow regulator and an approved check valve cartridge, however, the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum operating temperature 60°C.
Range of shower hoses and handsets (various finishes - see model) with EPDM ‘O’-rings. Maximum operating temperature 60°C.
Range of Y pattern strainers incorporating blue epoxy coated ductile iron bodies and stainless steel mesh filter. With PN16 flanges to BS EN 1092-2. Maximum working pressure 16.0 bar. Cold water use only.
Range of bib taps with DZR brass bodies. The inlet and the outlet of the tap incorporates approved single check valve cartridges however, the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum working pressure 16.0 bar. Maximum operating temperature 85°C.
Bib tap incorporating brass bodies. The inlet and the outlet of the tap incorporates approved single check valve cartridges however, the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum working pressure 16.0 bar. Maximum operating temperature 85°C.
Range of wall mounted hose union tap brass body incorporating a non-rising spindle headwork with a butterfly handle operating member. Maximum working pressure 16.0 bar. Maximum operating temperature 85°C.
Range of wall mounted hose union taps brass body incorporating a non-rising spindle headwork with a butterfly handle operating member. Maximum working pressure 16.0 bar. Maximum operating temperature 85°C.
Range of pillar taps (chrome plated brass) with quarter turn ceramic disc headworks and single lever operating members. The spout outlet incorporates a plastic flow straightener. The product is supplied with metal backnuts. Maximum working pressure 10.0 Bar Maximum operating temperature 60°C.
Range of pillar taps (chromium plated brass) incorporating quarter turn ceramic disc headworks with single lever or cross top operating members. The spout outlets incorporate a plastic aerator (AX-IRO-106-CP, AX-MET-106-CP & AX-MET-1369-CP models only) or a plastic flow straightener (AX-IRO-136-CP model only). The products are supplied with metal backnuts. Maximum working pressure 5.0 bar. Maximum operating pressure 60°C.
Pillar taps (chromium plated brass) incorporating quarter turn ceramic disc headwork with single lever or cross top operating members. The spout outlets incorporate a plastic aerator or flow straightener. The product is supplied with metal backnuts. Maximum working pressure 5.0 bar. Maximum operating pressure 60°C.
Pillar tap incorporating a ceramic cartridge headwork (chrome plated brass body) with a single lever operating member. The spout outlet incorporates a flow straightener and flow regulator. The product is supplied with plastic backnuts Maximum working pressure 10 bar. Maximum operating temperature 60°C
Range of pillar taps with brass bodies (various finishes - see model) incorporating quarter turn ceramic disc headworks with single lever operating members. The spout outlet incorporates a plastic flow straightener. The 4102BD18 models incorporate a plastic flow restrictor on the inlet. The products are supplied with plastic and brass backnuts. Maximum working pressure 10.0 bar. Maximum operating temperature 65°C.
Range of pillar taps with brass bodies (various finishes), incorporating quarter turn ceramic disc headworks with either cross top or single lever operating members. The spout outlet incorporates a plastic flow straightener. The product is supplied with metal backnuts. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.
Range of pillar taps (chromium plated brass), incorporating quarter turn ceramic disc headworks with single lever, dome type or cross top operating members and plastic backnuts. The spout outlets incorporate a plastic flow straightener. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.
Range of pillar taps (chromium plated brass), incorporating quarter turn ceramic disc headworks with single lever, dome type or cross top operating members and plastic backnuts. The spout outlets incorporate a plastic flow straightener. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.
Page 6 of 177
We use cookies to give you the best possible experience with WRAS. Some are essential to provide website functions and ensure the website is secure. We also use cookies to help us understand how people use the site and to make improvements. Click "Accept All" to enable recommended settings or click "Manage cookies" to adjust your settings. For more details, see our Cookie Policy.