Deck mounted two hole, single outlet (fixed) combination tap assembly (chromium plated brass), incorporating quarter turn ceramic disc headworks with single lever operating members and a lockable self- cancelling diverter to the shower outlet. Temperature is controlled independently via a thermostatic cartridge with a dome type operating member that incorporates a manual override button. Both inlets incorporate stainless-steel strainers and a single check valve cartridge (however, the complete product has not been fully tested to demonstrate it provides backflow protection). The spout outlet incorporates a plastic flow straightener and a stainless steel mesh Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.
A range of three hole, single outlet (fixed) combination tap assemblies with brass bodies (chromium plated), incorporating quarter turn ceramic disc headworks and various operating members (see models). The side valves and the spout are connection via stainless steel braided EDPM lined flexible hose assemblies incorporating ½” BSP captive nut end connections. Inlet to the main body incorporates a flow regulator. The products are supplied with metal back nuts and pop-up wastes. Maximum working pressure 5.5 bar. Maximum working temperature 60°C.
‘Purist’ range of three hole, single outlet (fixed) combination tap assemblies (brass bodies - various finishes, see model), incorporating quarter turn ceramic disc headworks with either single lever or cross top operating members. The spout outlets incorporate a plastic aerator. The product is supplied with stainless steel braided EPDM lined flexible hose assemblies for installation between the side valves and ‘T’ connector, and a pop-up waste. Maximum working pressure 4.1 bar. Maximum operating temperature 65°C.
Range of three-hole, single outlet (fixed) combination tap assemblies with brass bodies (various finishes) incorporating a quarter turn ceramic disc headworks with single lever operating members. The spout outlets incorporate plastic aerators. Some models are supplied with lever operated pop-up wastes. Maximum working pressure 5.0 bar
Non-metallic materials and components comply with BS6920 at 60°C
Range of basin spout outlets with brass bodies (various finishes), the outlet incorporates either a metal aerators, plastic aerators or open outlet (depending on model). Maximum working pressure 3.5 bar. Maximum operating temperature 60°C
Range of wall mounted spout outlets with either stainless steel or brass bodies (various finishes - see model), incorporating a plastic aerator and EPDM ‘O’-rings. Maximum working temperature 60°C.
Wall mounted spout outlet (brass bodies - various finishes) incorporating a plastic aerator. Maximum working pressure 10 Bar. Maximum operating temperature 60°C
Range of tap outlets with plastic bodies incorporating a filter within the body, incorporating a hollow fibre filter membrane. The inlet of the filter incorporates an approved check valve cartridge, however, the complete product has not been fully tested to demonstrate it provides backflow protection. The filters are supplied with (and must be used with) a chrome plated brass adapter which incorporates a pastic flow regulator. Maximum operating temperature 60°C.
‘Numepress’ range of stainless-steel crimp fittings incorporating EPDM and ‘O’-rings. For use with stainless steel tube. Maximum working pressure 16.0 bar. Maximum operating temperature 95°C.
Tigris K5 (PPSU - plastic body) and M5 (DZR brass body) ranges of press-fit (U, H, TH crimp profiles) fittings with stainless steel crimp sleeves and EPDM ‘O’-rings, for use with Tigris K1 multi-layer PEX-c/AL/PE-HD pipe. Maximum working pressure 6.0 bar. Maximum operating temperature 95°C.
Range of brass, chrome plated brass or DZR brass compression fittings for use with copper pipe only. Maximum working pressure 16.0 bar. Maximum operating temperature 85°C.
The 3G Metric Imperial range of plastic compression fittings with polypropylene bodies, compression nut and silicone seal for use with PE80 pipe (manufactured to BS EN 12201). Maximum working pressure: Fittings when used with PE100 pipe = 16.0 bar. Fittings when used with PE80 pipe = 12.0 bar. For above and below ground and cold water use only.
Range of PVC-u solvent weld and threaded union fittings incorporating an EPDM ‘O’-ring. For use with PVC-u pipe manufactured to ISO 1452 and DIN 8063. Maximum working pressure 10.0 bar. Cold water use only.
‘Xpress’ range of press fit fittings with copper or brass bodies and EPDM ‘O’-rings. For use with copper tube manufactured to EN1057. For above ground ground use only. Maximum working pressure 16.0 bar. Maximum operating temperature 100°C.
‘AF’ range of compression fittings with brass or chrome plated brass bodies for use with copper pipe (manufactured to EN1057). The AF14 and AF15 tap connector models incorporate an EPDM washer. Maximum working pressure 16.0 bar. Maximum working temperature 85˚C
‘Tectite Sprint’ range of pushfit fittings with copper or DZR brass bodies. 10mm, 15mm, 22mm & 28mm pushfit fittings are for use with copper pipe (manufactured to BS EN 1057) and polybutylene barrier pipe and cross linked PEX barrier pipe (manufactured to BS 7291). 35mm, 42mm & 54mm pushfit fittings are for use with copper pipe (manufactured to BS EN 1057) only. When used with PB & PEX pipes operating parameter are: 12.0 bar@cold water. 3.0 bar@92°C. When used with copper pipes operating parameter are: 20.0 bar@cold water. 10.0 bar@100°C.
‘Endex’ range of copper alloy and copper end feed fittings for use with copper pipe. For above ground use only. Maximum working pressure 16.0 bar. Maximum operating temperature 99°C.
Center Brand range of brass and copper end feed fittings for use with copper pipe. For above ground use only. Maximum working pressure 16.0 bar. Maximum operating temperature 99°C.
WC dual flush drop valve comprising of a plastic body, silicone seating washer and an internal overflow. The valve is operated via a push button assembly (not included) for either full or reduced flush. Cold water use only.
Range of stainless-steel plate heat exchangers with EPDM gaskets. The primary circuit, (excluding the E2 prefix models), incorporates a drain valve and a pump (excluding STP prefix models including an ‘N’ as the 14th figure). Operating parameters: Maximum working pressure of the secondary circuit: 6.0 bar or 10.0 bar (see model). Maximum working pressure of the primary circuit: E4 models: 6.0 bar. C3, E3, E2, i2: 10.0 bar. Models added February 2023 – Econoplate STP3, STC3, STP2, STC2 & STP4: 10.0 bar. Maximum operating temperature: Primary 140°C & Secondary 85°C.
Range of plate heat exchanger with stainless steel bodies. Maximum working pressure10 bar. Maximum operating temperature 100°C.
Range of under-sink, electrically heated vented water heaters (cased and insulated). Maximum operating temperature 98˚C
"Greenstar" range of indirect heat interface units and "Flow 8000" (added December 2024) range of direct heat interface units providing heating and instantaneous hot water. The heating system incorporates an expansion vessel. The products are sold with or without a prefix kit (see model), which comprises of a mounting bracket that includes spherical valves for all circuits. The "Greenstar" indirect models include a pressure relief valve (set at 3.0 bar) on the space (central) heating circuit. Greenstar models: Maximum working pressure district heating 10.0 bar. Maximum working pressure space heating 2.5 bar. Maximum working pressure secondary hot water 10.0 bar. Maximum operating temperature 60°C (secondary) and 90°C (primary). Flow 8000 models (added December 2024): Maximum working pressure district and space heating 10.0 bar. Maximum working pressure secondary hot water 10.0 bar. Maximum operating temperature 60°C (secondary) and 90°C (primary).
Union ball, non-return valve with a plastic PVC body. Maximum working pressure 10.0 bar. Cold water use only.
Range of pressure transmitters with stainless steel bodies. Maximum working pressure 10.0 to 200.0 bar (please refer to model). Maximum operating temperature 100°C.
Range of click type pop-up wastes with brass bodies. Maximum operating temperature 60°C.
Range of vertical multistage pumps with stainless-steel bodies, stainless-steel impellers, shaft and outer sleeve. Maximum working pressures: T (oval flange): 16.0 bar. V (Victaullic & grooved), C (clamp flanges) & F (round flange) versions: 26.0 bar. Maximum operating temperature 100°C.
Range of multistage pumps with brass suction and discharge bodies, stainless steel housing, shaft and impeller, and EPDM ‘O’-rings and seals. Maximum working pressure: 6.0 bar (41491 & 41492 models) or 9.0 bar (41493 & 41494 models). Maximum operating temperature 65°C.
Range of vertical multistage booster pumps, with stainless steel bodies and impellors. Maximum working pressure is either 16.0 or 25.0 bar depending on specific model. Maximum operating temperature 85°C.
Range of vertical multistage pumps with stainless-steel bodies, stainless-steel impellers, shaft and outer sleeve. Maximum working pressures: T (oval flange): 16.0 bar. V (Victaullic & grooved), C (clamp flanges) & F (round flange) versions: 26.0 bar. Maximum operating temperature 100°C.
‘3ME’ Range of horizontal pumps with stainless steel bodies and impellers, and EPDM ‘O’-rings. The products are supplied with a carbon/ceramic/EPDM shaft seal. Maximum working pressure 10.0 bar. Maximum operating temperature 100°C.
Range of overhead showers with brass and plastic bodies (various finishes - see models). The inlet incorporates a stainless-steel strainer and a plastic strainer. Products to be used with basic sets with brass bodies and EPDM O-rings. Open outlet use only
Non-metallic materials and components comply with BS6920 at 60°C
Range of filter type fixed ‘shower’ outlets and shower handsets with plastic bodies. Maximum operating temperature 45°C.
Range of shower handsets with brass bodies available in various styles and finishes. The inlets incorporate an approved check valve cartridge, however, the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum operating temperature 60°C.
Range of shower outlets and shower kits. Shower outlets consisting of wall and ceiling mounted shower heads and hand shower. The inlets incorporate stainless steel flow regulators and approved check valve cartridges, however, the complete product has not been fully tested to demonstrate it provides backflow protection. The shower kits can consist of shower hose, shower handset, riser rail and wall outlet elbow with bracket (depending on model). Shower handset inlet incorporates a stainless-steel strainer. Both the outlet of the wall elbow and inlet of shower handset incorporates an approved check valve cartridge, however, the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum operating temperature 60°C.
Range of shower outlets (celing or wall mounted arms - see model) with chrome plated brass bodies and silicone nozzles. The products incorporate a swivel joint connection to the shower head which incorporates a combined NBR washer and stainless steel strainer. All models, except for the 15199 model, include a plastic flow regulator on the inlet to the shower head. Maximum operating temperature 60°C.
Range of shower handsets with either stainless steel or brass bodies (various finishes). Product is supplied with a metal sheathed flexible hose. Maximum operating temperature 60°C.
Range of shower heads with or without wall connectors (see models) with plastic bodies (various finishes). The shower heads incorporate a stainless-steel strainer and plastic flow regulator on the inlet. Model added September 2023: Wall mounted, brass shower arm (various finishes - see model). Non-metallic materials and components comply with BS6920 at 60°C Models added September 2023 and January 2024: Non-metallic materials and components comply with BS6920 at 65°C
Non-metallic materials and components comply with BS6920 at 60°C
A range of shower kits and hand showers incorporating metal bodies (chrome plated). Some models are supplied with sliding rails, wall elbows and shower hoses (see models). Maximum working temperature 60°C.
Range of handshower holders with brass bodies (various finishes). The outlet incorporates an approved check valve cartridge, however, the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum operating temperature 65°C
Range of shower heads with brass bodies (various finishes), incorporating EPDM ‘O’-rings and plastic flow regulator. Maximum operating temperature 60°C.
Range of wall mounted hose union taps (brass body or DZR brass body - see model) incorporating a non-rising spindle headwork with a ‘T’-type operating member. The 1BCB001 & 1BCB701 models incorporate two approved single check valve cartridges, however the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum working pressure 14.0 Bar. Maximum operating temperature 85°C.
Range of wall mounted hose union taps (brass body or DZR brass body - see model) incorporating a non-rising spindle headwork with a ‘T’-type operating member. Maximum working pressure 14.0 Bar. Maximum operating temperature 85°C.
Range of stainless steel and brass double interlocked PEX lined flexible hose assemblies (various finishes - see model) incorporating EPDM washers. Maximum working pressure 5.0 bar. Maximum operating temperature 80°C.
Range of PET (Polyethylene terephthalate) braided flexible hoses incorporating PEX liner and EPDM ‘O’-rings. Maximum working pressure 5.0 bar. (10.0 bar for models added September 2025). Maximum operating temperature 70°C.
‘Comet’ combination units consisting of a cased and insulated stainless steel unvented hot water storage cylinder. The cylinder primary circuit is fitted with an in-line electrical heater which supplies the heat source to the secondary water via a stainless-steel coil, and the heat source to the central heating circuit directly. The cylinder is factory fitted with a temperature and pressure relief valve, pre-set at 7.0 bar 90 degrees. The unit is supplied with an inlet control group containing a check valve cartridge, verified by test (suitable for backflow protection against Fluid Category 2), pressure reducing valve set at 3.0 bar and an expansion relief set at 6.0 bar. An expansion vessel is factory fitted to both the secondary and primary circuits within and is positioned inside the casing. The primary circuit also incorporates a circulating pump and pressure relief valve which is set at 3.0 bar. Maximum secondary working pressure 5.5 Bar Maximum Primary working pressure 2.5 Bar Maximum operating temperature 65.0 °C
Range of wall mounted, manually operated, concealed blending valves with brass bodies (chrome plated) faceplates, incorporating a ceramic cartridge headwork with a single lever operating member controlling both flow and temperature. The inlets incorporate approved check valve cartridges, however, the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C
Range of deck mounted, manually operated, concealed blending valves with chromium plated brass bodies and either brass or stainless-steel trim (see model). The product incorporates a ceramic cartridge headwork with a single lever operating member. The product is supplied with a stainless steel braided PEX lined flexible hose assembly incorporating a ¾” captive nut end connection for installation on the outlet. Maximum working pressure 10.0 bar. Maximum operating temperature 65°C.
Range of wall mounted, concealed or exposed thermostatic shower valves (chromium plated brass), incorporating a single sequential headwork controlling both flow and temperature via a single lever operating member. Each inlet elbow incorporates a combined TPE washer and stainless-steel strainer. The main valve body inlets each incorporate approved check valve cartridge, however, the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum working pressure 10.0 bar. Maximum operating temperature 65°C.
Range of wall mounted thermostatic bar shower valves incorporating a thermostatic cartridge controlling the temperature with a dome operating member incorporating a manual override button. The flow to the handset or overhead shower is via a ceramic disc headwork with a dome operating member. Inlets Incorporate approved check valve cartridges, however, the complete product has not been fully tested to demonstrate it provides backflow protection. RRK models are also supplied with shower hose, handset, overhead shower head and riser rail. Maximum working pressure 5.0 bar. Maximum operating temperature 65ºC.
Page 6 of 25
We use cookies to give you the best possible experience with WRAS. Some are essential to provide website functions and ensure the website is secure. We also use cookies to help us understand how people use the site and to make improvements. Click "Accept All" to enable recommended settings or click "Manage cookies" to adjust your settings. For more details, see our Cookie Policy.