Range of wall mounted spout outlets with brass bodies (chrome plated). Product is supplied with various operating members and pop up click waste. Maximum working pressure 5.5 bar. Maximum operating temperature 60°C.
Chlorine dioxide dosing system consisting of PVC-U pipework and fittings. Maximum operating pressure 7.0 bar. Cold water use only.
‘Profine’ plastic bodied filter head incorporating EPDM ‘O’-rings for use with filter cartridges (not supplied).For use with LLDPE tube (manufactured to DIN 8072). All models can be specified with or without an integral bracket. Maximum working pressure 6.0 bar. Cold water use only.
Range of brass, chrome plated brass or DZR brass compression fittings for use with copper pipe only. Maximum working pressure 16.0 bar. Maximum operating temperature 85°C.
Range of M type press fittings with TP2 copper bodies and EPDM ‘O’-rings, for use with TP2 copper pipe to EN1057. Above ground use only. Maximum working pressure 16.0 bar. Maximum operating temperature 85°C.
Copper brazed micro plate heat exchanger with copper and stainless-steel (316/1.4401) plates. Maximum working pressure 25.0 Bar. Maximum operating temperature 100°C
Range of ice making machines. The inlet supply is controlled by a solenoid valve. Inlet hose supplied. Maximum working pressure 5.0 bar. Cold water use only.
Range of commercial air or liquid cooled ice making machines with flow controlled via solenoid valve. Maximum working pressure 7.8 Bar. Cold water use only.
Range of meter boxes incorporating a plastic manifold arrangement consisting of a stop valve with non-rising spindle , check valve (however the complete assembly has not been tested to demonstrate it provides adequate backflow) and concentric meter port. Some models incorporate a drain off or blacking plug. Connections can be compression or push fit (see model). For use with PE8-0 pipe to BS EN 12201 and copper to EN 1057. Maximum working pressure 16.0 bar. Cold water use only.
Bath spout incorporating a brass body (various finishes), EPDM ‘O’-rings and a plastic flow straightener. Maximum operating temperature 60°C
Range of pushfit hose connectors with either plastic (white or black) or chrome plated brass bodies and EPDM ‘O’-rings. SHCV prefix models incorporate screwdriver operated servicing valves. All pushfit connections are for use with PEX pipe (manufactured to BS7291-3) and copper pipe (manufactured to EN1057). Barbed end connections are not approved for use with any hose. Chrome plated brass body models are also for use with PB pipe (manufactured to BS7291-2). Maximum working pressure 10.0 bar (servicing valve models only). Barbed end connections are open outlet use only. Cold water use only.
Range of water hammer arrestor’s incorporating brass bodies (various finishes). The 525152 model is supplied with a reinforced captive nut. Maximum working pressure 10.0 bar. Maximum operating temperature 65°C. For products manufactured from June 2023 Maximum operating temperature 85°C
Chrome plated brass quick connector with EPDM washer. Maximum operating temperature 60°C.
Range of bidet spray kits comprising of a hand set with self-closing trigger, wall bracket, flexible hose assembly, thermostatic blending valve and isolation valve. Maximum working pressure 5 bar. Maximum working temperature 60°C
“Silent” range of booster pumps with plastic bodies and impellers and NBR ‘O’-rings. The SM900165A & SM600165A models incorporate a non-return valve on the outlet. Maximum working pressure 3.2 bar. Maximum operating temperature 35°C.
‘Para Z’ range of circulating pumps with either stainless steel, bronze or plastic bodies. Maximum working pressure 10.0 bar. Maximum operating temperature 85°C.
Range of shower heads with plastic bodies and a brass inlet connection. The inlet of the shower head incorporates an approved check valve cartridge, however, the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum operating temperature 70°C.
Shower handset with a plastic body (various finishes - see model). Maximum operating temperature 60°C.
Shower handset with a plastic body in a variety of finishes (see model). The inlet incorporates a combined EPDM washer and stainless-steel strainer, and a plastic flow regulator. Maximum operating temperature 60°C.
Range of wall mounted and overhead shower outlets, incorporating stainless steel strainers and flow regulators at the inlets. Maximum operating temperature 60°C
Shower outlets incorporating chrome plated ABS bodies. Maximum operating temperature 65°C.
Range of overhead showers and shower handsets with plastic body (various finishes). Overhead shower inlets incorporate a stainless steel strainer Maximum operating temperature 60°C.
Range of shower handsets incorporating plastic bodies (various finishes), plastic flow regulators and stainless steel strainers. Maximum operating temperature 60°C.
Range of shower kits, shower outlets and shower hoses. The shower handsets and overhead shower inlets incorporate a plastic flow regulator. Maximum operating temperature 45°C.
Shower handset with a plastic body in a variety of finishes (see model). The inlet incorporates a combined EPDM washer and stainless-steel strainer, and a plastic flow regulator. Maximum operating temperature 60°C.
Shower kit consisting of a wall mounted elbow (brass body various finishes - see model), shower hose and handset. The outlet of the wall elbow incorporates a single check valve cartridge, however, the complete product has not been fully tested to demonstrate it provides backflow protection. The shower handset inlet incorporates a stainless-steel strainer and a plastic flow regulator. Maximum operating temperature 60°C.
Range of shower outlets and shower handsets. The shower heads have a brass body and ball joint, NBR ‘O’-ring, stainless-steel strainer and silicon nozzles. The shower handset has a brass body, NBR ‘O’-rings, silicon nozzles and incorporate a plastic flow regulator on the inlet. Model ‘100274774 N200000068’ is supplied with a double interlocked hose and a single check valve cartridge (to be installed on the inlet to the hose) however the complete product has not been fully tested to demonstrate it provides backflow protection. Model ‘100274774 N200000068’ has a maximum operating temperature of 60°C. All other models have a maximum operating temperature of 85°C.
Range of bib taps incorporating brass bodies. The BTHUCV1/2 and BTHUCV3/4 models incorporate an approved single check valve cartridge on the inlet and the outlet (hose union), however, the complete product has not been fully tested to demonstrate it provides backflow protection. The BTHUCV1/2 and BTHUCV3/4 models also incorporate a drain port. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.
Range of bib taps with (chrome plated) brass bodies, brass ball spherical valve with PTFE seals and a single lever operating member. The spout outlet incorporates a hose union spigot connection. Maximum working pressure 10.0 Bar Maximum operating temperature 85°C
Range of pillar taps incorporating brass bodies (various finishes), quarter turn ceramic disc headworks and various operating members. Spout outlets incorporate either a plastic aerator or flow straightener (all models apart from STA13-QT). Fittings are supplied with metal backnuts Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.
Range of flexible shower hoses incorporating a PVC inner lining, corrugated stainless steel outer layer (various finishes) and silicone washers. Maximum operating temperature 65°C.
Range of shower hoses with PVC outer (various finishes - see model), PET reinforcement layer, PVC inner liner and EPDM washers. Maximum operating temperature 65°C.
Range of interlocking metal shower hoses with silicone liner and EPDM washers. Maximum operating temperature 70°C.
Range of manually operated, wall mounted, concealed blending valves with brass bodies (various finishes - see model), incorporating a ceramic cartridge headwork with a single lever operating member. Maximum working pressure 5.0 bar. Maximum operating temperature 85°C.
Range of manually operated, wall mounted, concealed blending valves with brass bodies (various finishes - see model), incorporating a ceramic cartridge headwork with a single lever operating member and self-cancelling diverter. Maximum working pressure 5.0 bar. Maximum operating temperature 85°C.
Range of wall mounted, exposed, thermostatic shower mixing valves with brass bodies (various finishes - see model) incorporating a quarter turn ceramic disc headwork controlling the flow with a dome type operating member. The temperature is controlled independently via a thermostatic cartridge with a dome type operating member that also incorporates a manual override button. Both inlets incorporate a combined NBR washer and stainless-steel strainer, as well as an approved single check valve cartridge, however, the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.
Range of adjustable T-type thermostatic mixing valves with brass bodies (chrome plated). Each inlet incorporates a stainless steel strainer and an approved check valve cartridge, however the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum working pressure 10.0 bar. Maximum operating temperature 85°C.
T-type mixing valve with a DZR brass body (nickel plated), temperature is controlled by a thermostatic cartridge. Each inlet incorporates a combined EPDM washer and stainless steel strainer, and a single check valve cartridge, verified by test (suitable for backflow protection against Fluid Category 2). For use with copper pipe manufactured to EN1057. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.
T-type mixing valve with a DZR brass body (nickel plated), temperature is controlled by a thermostatic cartridge. For use with copper pipe manufactured to EN1057. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.
Range of wall mounted, bar type, thermostatic shower blending valves (chromium plated brass), incorporating a ¼ turn ceramic disc headwork controlling the flow with a dome type operating member. The temperature is controlled independently via a thermostatic cartridge with a dome type operating member incorporating a manual override button. Both inlets incorporate a stainless steel strainer and an approved check valve cartridge, however the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum working pressure 10.0 bar. Maximum operating temperature 65°C.
Range of wall mounted, concealed, thermostatic shower valves with brass bodies and trim sets (various finishes - see models). Flow is controlled as follows (for operating members - see model): Single outlet models: ¼ turn ceramic disc headwork. Double Outlet Models without diverter: ¼ turn ceramic disc headworks. Double Outlet Models with diverter: 2-way ceramic disc diverter headwork. Triple Outlet Models with diverter: ¼ turn ceramic disc headwork and a 2-way ceramic disc diverter headwork. The temperature is controlled independently via a thermostatic cartridge with various operating members (see model) which incorporates a manual override button. The inlets incorporate a single check valve cartridge, however, the complete assembly has not been tested to demonstrate it provides backflow protection. Specific models are supplied with a shower hose and handset (see models). Maximum working pressure 5.0 Bar Maximum operating temperature 60°C
Wall mounted bar type thermostatic mixing valve (chromium plated brass) incorporating a ¼ turn ceramic disc headwork controlling the flow with a dome type operating member and a secondary ceramic disc headwork diverting the flow between the overhead shower and hand shower with a single lever operating member. The temperature is controlled independently via a thermostatic mixing cartridge with a dome type operating member that incorporates a manual override button. Both inlets incorporate single check valve cartridges, however, the complete assembly has not been tested to demonstrate it provides backflow protection. The product is supplied with a fixed overhead shower, shower handset and hose. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.
Wall mounted, concealed, 2-way diverter valve (brass body and chrome trim set) with a single lever operating member. Maximum working pressure 5.0 bar. Maximum operating temperature 65°C.
Range of non return valves incorporating bronze bodies and discs, and PTFE washer. Maximum working pressure 20.0 bar. Maximum operating temperature 85°C.
Manually adjustable pressure reducing valve, which incorporates a DZR brass body and an in-line double check valve assembly on the inlet (verified by test as suitable for backflow protection against Fluid Category 3). The outlet incorporates a shut-off valve. Maximum supply pressure 16.0 bar. Maximum outlet pressure between 1.5 bar and 6.0 bar. Maximum operating temperature 40°C.
Range of 5 way inlet control group assembly incorporating a DZR brass body incorporating a pressure reducing valve, with an adjustable outlet pressure range of either 3.0 bar, 3.5 bar, or 6.0 bar and a safety relief valve set at either 6.0 bar or 8.0bar (depending on model). The product incorporates an inline single check valve cartridge after the balanced cold take off, verified by test (suitable for backflow protection against Fluid Category 2). Maximum supply pressure 10.0 bar. Maximum operating temperature 85°C
Range of pre-set, spring loaded, angled pressure relief valves with plastic body and EPDM diaphragm. The valves are fitted with rotary type easing gear . For maximum working pressure please refer to model. Maximum operating temperature 99°C.
Range of latching and normally closed (see model) solenoid valves with plastic bodies, NBR diaphragms and ‘O’-rings. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C
Range of lever operated spherical valves incorporating brass bodies (chrome plated), brass balls and PTFE seals. Maximum working pressure 40.0 bar. Maximum operating temperature 100°C.
Flow through valve with a brass body and EPDM ‘O’-rings, incorporating a spherical valve and a separate drain port/plug. Maximum working pressure 10.0 bar. Maximum operating temperature 65°C.
Page 41 of 226
We use cookies to give you the best possible experience with WRAS. Some are essential to provide website functions and ensure the website is secure. We also use cookies to help us understand how people use the site and to make improvements. Click "Accept All" to enable recommended settings or click "Manage cookies" to adjust your settings. For more details, see our Cookie Policy.