Range of brass interlocked shower hoses (various finishes - see model) with TPE inner liner and NBR washers. Maximum operating temperature 65°C.
Wall mounted, manually operated, blending valve (chromium plated brass body) incorporating a ceramic cartridge headwork with a single lever operating member. The inlets incorporate approved check valve cartridges; however, the complete product has not been fully tested to demonstrate it provides backflow protection Maximum working pressure 10.0 Bar Maximum operating temperature 60.0°C
Range of wall mounted, concealed, manual blending bath shower mixers (brass bodies, various finishes - see model) incorporating a ceramic cartridge headwork with a single lever operating member and a self-cancelling diverter (to divert the flow between a shower outlet or bath spout outlet - not supplied). The products comprise of a basic set, (concealed body), which includes the ceramic cartridge and a finish set that includes the self-cancelling diverter, headwork collar, operating member and trim set. Maximum working pressure 10.0 bar. Maximum operating temperature 70°C.

Wall mounted, manual blending valve (brass body, various finishes - see model) incorporating a ceramic cartridge headwork with a single lever operating member. The shower outlet incorporates an approved check valve cartridge, however, the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.
Wall mounted, concealed, thermostatic blending valve with brass body and chrome plated trim set. Incorporating a thermostatic cartridge headwork with dome type operating member incorporating a manual override button. The valve is supplied with a shower hose and handset. Maximum working pressure 5.0 bar. Maximum operating temperature 50°C.
Range of wall mounted, thermostatic, shower mixers incorporating brass bodies (various finishes) 2-way ceramic disc diverter headwork to control the flow between two shower outlets with various operating members (see model). Temperature is controlled independently via a thermostatic cartridge using various operating members (see model) that also incorporates a manual override button. The inlets incorporate a combined EPDM washer and stainless-steel strainer and an approved check valve cartridge, however, the complete product has not been fully tested to demonstrate it provides backflow protection. The inlet of the overhead shower incorporates a combined EPDM washer and stainless-steel strainer. The products are supplied with a shower head, shower hose and handset. Maximum working pressure 10.0 Bar. Maximum operating temperature 60°C.
Concealed, thermostatic shower blending valve, incorporating a brass body and a (chrome plated) trim set. The trim set comprises of a 2 way ceramic disc diverter headwork with a dome type operating member controlling the flow, and a thermostatic cartridge controlling the temperature with a dome type operating member incorporating a manual override button. The trim set is also supplied with two brass assemblies comprising of a plastic filter, EPDM ‘O’-rings and an approved check valve cartridge, however the complete assembly has not been tested to demonstrate it provides adequate backflow protection.. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.
Range of wall mounted exposed thermostatic mixing valves with brass bodies (various finishes). Incorporating a ceramic disc headwork with single lever operating member controlling the flow of the outlet on the bottom of the valve and three push button cartridges, two control the flow to outlets at the rear of the valve, and one to the outlet on the bottom of the valve all with cube type operating members. The temperature is controlled independently via thermostatic cartridge with a dome type operating member with a manual override button. The inlets and outlet at the bottom of the valve incorporate an approved check valve cartridge; however, the complete product has not been fully tested to demonstrate it provides backflow protection. The inlets incorporate stainless steel strainers. Maximum working pressure 10.0 bar. Maximum working temperature 65°C.
Range of wall mounted exposed thermostatic mixing valves with brass bodies (various finishes). Incorporating a ceramic disc headwork with a single lever operating member controlling the flow to a hose outlet and then two push button cartridges, one controls the flow to an outlet at the rear of the valve and the other to the outlet on the bottom of the valve with cube type operating members. The temperature is controlled independently via thermostatic cartridge with a dome type operating member with a manual override button. The inlets and outlet at the bottom of the valve incorporate an approved check valve cartridge; however, the complete product has not been fully tested to demonstrate it provides backflow protection. The inlets incorporate stainless steel strainers. Maximum working pressure 10.0 bar. Maximum working temperature 65°C.
Wall mounted, exposed thermostatic shower valve (brass body, various finishes) incorporating a non-rising spindle headwork controlling the flow with a dome operating member. The temperature is controlled independently via a thermostatic cartridge with a dome operating member which incorporates a manual override button. Both inlets incorporate stainless steel strainers and an approved check valve cartridge, however the complete product has not been fully tested to demonstrate it provides backflow protection Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.
Range of wall mounted, bar type thermostatic shower mixers (various finishes). Incorporating a quarter turn ceramic disc headwork controlling the flow to the outlet with a dome type operating member. The temperature is controlled independently via a thermostatic cartridge with a dome type operating member with a manual override button. Both inlets incorporate stainless steel strainers and an approved check valve cartridge however, the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum working pressure 10.0 bar. Maximum operating temperature 70ºC.
Range of concealed, wall mounted thermostatic blending valves (cast brass bodies). All models incorporate a thermostatic cartridge to control the temperature. GOO.5500AE/W/A00 model has a top outlet with a 2 way diverter controlling the flow. GOO.5600AE/W/A00 model has a top outlet with a 3 way diverter controlling the flow. GOO.5540AE/W/A00 model has a top outlet with a 2 way diverter and a bottom outlet with a quarter turn ceramic disc headwork controlling the flow. GOO.5200AE/W/A00 model is just a thermostatic cartridge (no flow control). GOO.5300AE/W/A00 model has a top outlet with a quarter turn ceramic disc headwork controlling the flow. GOO.5300AE/W/A00 model has a top and bottom outlet both with a quarter turn ceramic disc headwork controlling the flow inlets incorporate approved check valve cartridges however, the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.
Wall mounted, thermostatic mixing valve (chromium plated brass body), the flow is controlled by a non-rising spindle headwork with a dome operating member and the temperature is controlled independently via a thermostatic cartridge with a dome operating member and manual override button Both inlets incorporate stainless steel strainers and approved check valve cartridges, however, the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum working pressure 5.0 bar. Maximum operating temperature 55°C.
Range of wall mounted (concealed) thermostatic shower mixers (brass bodies), incorporating half turn ceramic disc headworks controlling the flow with dome type operating members. Temperature is controlled independently via a thermostatic cartridge with a dome operating member and manual override button. Both inlets incorporate approved check valve cartridges, however, the complete product has not been fully tested to demonstrate it provides backflow protection. The products are supplied with a shower arm, overhead shower, shower hose and shower handset. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.
Range of T-type thermostatic mixing valves with DZR brass bodies. The inlets incorporate a stainless-steel strainer and a single check valve cartridge, verified by test (suitable for backflow protection against Fluid Category 2). Maximum working pressure 10 Bar Maximum operating temperature 90°C
Range of wall mounted concealed thermostatic mixing valves with brass bodies. Flow is controlled by either a 2-way combined shut off/diverter cartridge or a ceramic disc headwork with various operating member (see models). The temperature is controlled independently via a thermostatic cartridge with a various operating member that also incorporates a manual override button. The inlets incorporate a single check valve cartridge, however, the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.
Wall mounted thermostatic shower valve (chromium plated brass), incorporating a single sequential headwork controlling both flow and temperature using a single lever operating member. The inlets incorporate flow regulators, plastic strainers and approved single check valve cartridges, however the complete product has not been fully tested to demonstrate it provides backflow protection. The product is supplied with a chrome plated shower handset, shower hose and riser rail assembly. Maximum working pressure 10.0 bar. Maximum operating temperature 65°C.
Wall mounted thermostatic shower valve (chrome plated brass), incorporating a non-rising spindle headwork controlling the flow and a thermostatic cartridge independently controlling the temperature, both using single lever operating members. The inlets incorporate flow regulators, plastic strainers and approved single check valve cartridges, however the complete product has not been fully tested to demonstrate it provides backflow protection. Products are supplied with a chrome plated shower handset, shower hose and riser rail assembly. Maximum working pressure 10.0 bar. Maximum operating temperature 65°C.
Wall mounted, thermostatic shower valve with chromium plated brass body. Flow is controlled by a quarter turn ceramic disc headwork with a single lever operating member. Temperature is controlled independently by a thermostatic cartridge with a dome type operating member that incorporates a manual override button. The inlets incorporate stainless steel strainers and an approved check valve cartridge however, the complete product has not been fully tested to demonstrate it provides backflow protection. The product is supplied with shower hose, handset, and riser rail. Maximum working pressure 10.0 Bar Maximum operating temperature 70°C.
Three-hole deck mounted thermostatic blending valve with brass body (chromium plated brass) incorporating a ceramic cartridge headworks with single lever operating members and a lockable self-cancelling diverter to shower outlet. The inlet to the shower handset incorporates an approved check valve cartridge, however, the complete product has not been fully tested to demonstrate it provides backflow protection Maximum working pressure 5.0 bar. Maximum working temperature 60°C
Range of wall mounted thermostatic shower valves (chrome plated brass bodies) incorporating a two-way diverter valve controlling the flow between shower outlets with a dome type operating member. The temperature is controlled independently via a thermostatic cartridge with a dome type operating member with manual override button. Both inlets incorporate approved check valve cartridges, however, the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum working pressure 10.0 bar. Maximum operating temperature 85°C.
Three-way diverter valve with a stainless-steel body and stainless-steel ball. Maximum working pressure 9.8 bar Maximum operating temperature 80°C.
Range of spring-loaded resilient trim, non-return valves with blue epoxy coated ductile iron bodies, stainless steel discs and EPDM seals. Maximum working pressure 16.0 bar. Maximum operating temperature 80°C.
Range of in line adjustable pressure reducing valves with (brushed chrome plated) DZR brass bodies for use with copper pipe manufactured to EN1057. The valves incorporate stainless steel strainers and are supplied with pressure gauges. Maximum supply pressure 16.0 bar. Outlet pressures are adjustable between 1.0 and 6.0 bar. Maximum operating temperature 85°C
EV220 BW range of normally closed solenoid valves with brass bodies, EPDM diaphragms and ‘O’-rings and stainless steel strainer. Maximum working pressure 10.0 bar. Maximum operating temperature 70°C.
Range of lever operated spherical valves incorporating brass bodies (nickel plated), brass balls (chrome plated) and EPDM ‘O’-rings. Maximum working pressure 10.0 bar. Maximum operating temperature 85°C.
Range of spherical valves with DZR brass bodies, chrome plated brass ball and PTFE seats with tee-handles or lever type or extension stem type operating members. Maximum working pressure 16.0 bar. Maximum operating temperature 85°C
Range of spherical valves with brushed chrome brass bodies, chrome plated brass ball incorporating a PTFE seat and NBR O rings. For use with EN1057 copper pipe. Maximum working pressure 25.0 bar. Maximum operating temperature 85°C
Range of spherical isolation valves incorporating brass bodies (nickel plated), brass ball (chrome plated), brass stem and EPDM ‘O’-rings (screwdriver operated or T-type handle). For use with copper pipe (EN1057). Maximum working pressure 16.0 bar (model 10.60982.015.CP12-8510) Maximum working pressure 25.0 bar (model 10.62022.015.CP12-8510) Maximum working pressure 40.0 bar (models 10.61062.015.CP12-8510 & 10.61062.022.CP12-8510) Maximum operating temperature 85°C.
Range of inline or angled ball valves with brass or nickel-plated brass bodies, chrome plated brass balls and a lever, butterfly or lockshield operating members. Maximum working pressure 16.0 bar. Maximum operating temperature 99°C.
Range of spherical valves with DZR brass bodies, chrome plated brass ball and PTFE seats with tee-handles or lever type or extension stem type operating members. Maximum working pressure 16.0 bar. Maximum operating temperature 85°C
Range of gate valves incorporating a blue epoxy coated cast iron body, EPDM gate and seals and a non-rising stem with a handwheel operating member Maximum working pressure 16.0 bar, Maximum operating temperature 85ºC.
Range of angle valves (chromium plated brass bodies) with EPDM O-rings and washers. The products incorporate non-rising spindle headworks with dome type operating members. Maximum working pressure 10 bar. Maximum working temperature 80°C.
Range of double regulating valves incorporating bronze bodies, brass disc face (½” - ¾” models) or PTFE (1” - 2” models), PTFE plate and NBR ‘O’-rings. Maximum working pressure 25.0 bar. Maximum operating temperature 100°C.
‘KHS CoolFlow’ range of cold water thermostatic balancing valves, incorporating gunmetal bodies,PTFE seats and EPDM ‘O’-rings. The 6150G01500 and 6160G01500 models are servo controlled (230V and 24V respectively), the 6170G01500 model is manually controlled. Maximum working pressure 10.0 bar. Maximum operating temperature 50°C.
Range of commercial front loading washing machines with flow controlled by solenoid valve and discharged via a type AD air gap arrangement (verified by test - suitable for backflow protection against fluid category 5). The product is supplied with a single check valve assembly (suitable for backflow protection against Fluid Category 2) and PEX lined rubber inlet connections hoses. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C
Range of UV disinfection units with stainless steel bodies and quartz tube. Maximum working pressure 10.0 bar. Cold water use only.
Range of UV disinfection units with stainless steel bodies and EPDM seals. The UV lamps are housed inside quartz tubes. Maximum working pressure 10.3 bar. Maximum operating temperature 40°C.
Range of UV disinfection units with stainless steel bodies & quartz tubes. All models incorporate a spherical valve on the drain outlet. Maximum working pressure 16.0 bar. Maximum operating temperature 50°C
'Delrin® FG511DP NC010'. White coloured, injection moulded semi-opaque acetal material. For use with water up to 85°C.
'M9000'. Grey coloured, injection moulded POM material. For use with water up to 85°C.
'SOLID-02'. Factory applied, black coloured, bituminous coating. Apply as per manufacturer's user instructions 'File No.: SOLID-0069, Vison: SLD-03, Date of issue: 2015-01-01'. Cure for 2 hours @60°C. For use with water up to 23°C. This material is only approved for the curing conditions that appear on the approval. If the cure conditions are varied from those specified on the approval then the material is not covered by the scope of the approval.
'AMMT-001G Two Component Epoxy Resin Coating/Ceramic Epoxy Coating'. Factory applied, off-white coloured, two-component epoxy coating. Components A and B are preheated to 60°C, mixed in a volume ratio of 1:1.& applied as per manufacturer's instructions 'version 2.00', dated '11/01/2021'. Cure for 1 hour@60°C. For use with water up to 23°C. This material is only approved for the mixing and curing conditions that appear on the approval. If the mix and/or cure conditions are varied from those specified on the approval then the material is not covered by the scope of the approval.
'POWTON E5000P-WT'. Factory applied, blue coloured epoxy powder coating. Apply as per manufacturer's TDS 'issue reference SPI 20170215' dated 21st January 2015. Cure for 15 minutes@230°C. For use with water up to 85°C. This material is only approved for the curing conditions that appear on the approval. If the cure conditions are varied from those specified on the approval then the material is not covered by the scope of the approval.
'POWTON E5000P-WT (grey)'. Factory applied, grey coloured, epoxy powder coating. Apply as per manufacturer's TDS dated January 21st 2015. Cure for 15 minutes@230°C. For use with water up to 85°C. This material is only approved for the curing conditions that appear on the approval. If the cure conditions are varied from those specified on the approval then the material is not covered by the scope of the approval.
'Jotaguard VA 5001'. Blue coloured, factory applied, Fusion Bonded Epoxy Powder Coating. Apply as per manufacturer's application guide dated 'October 2018'. Cure for 5 minutes@245°C. For use with water up to 85°C. This material is only approved for the curing conditions that appear on the approval. If the cure conditions are varied from those specified on the approval then the material is not covered by the scope of the approval.
'JPC Liquid Epoxy Paint'. Factory applied, red coloured, two-component epoxy paint. Mix components A & B in a 3:1 volume ratio and apply as per manufacturer's instructions ' JPC-FG-A/06-21/009 & JPC-FG-B/06-21/009' dated '02/06/2021'. Cure for 7 days@34°C. For use with water up to 23°C. This material is only approved for the mixing and curing conditions that appear on the approval. If the mixing and/or curing conditions are varied from those specified on the approval then the materials are not covered by the scope of the approval.
'KARUMEL EX4412 (RAL5005) & KARUMEL EX4412 (Blue)'. Factory applied, blue coloured epoxy powder coatings. Apply as per manufacturer's application guide for potable water reference number 'KCSA-21090101' dated September 2021. For use with water up to 85°C. This material is only approved for the curing conditions that appear on the approval. If the cure conditions are varied from those specified on the approval then the material is not covered by the scope of the approval.
'LNXFSY'. Factory applied, grey coloured Portland Cement Mortar. Mix cement, sand and water in a 2:1:0.4 mass ratio and apply as per manufacturer's instructions issue 'X202101207F' dated '2021-12-07'. Cure for 12 hours@55°C. For use with water up to 65°C. This material is only approved for the mixing and curing conditions that appear on the approval. If the mixing and/or curing conditions are varied from those specified on the approval then the materials are not covered by the scope of the approval.
'Ya-Coat Amiantit (SADIP)'. Factory applied, two-component, green coloured (once mixed and applied) PU coating. Mix base and hardener in a 3:1 volume ratio and apply as per manufacturer's process document 'MW 106-5 issue 1', dated 26/06/2007. Cure for 10 minutes@35°C. For use with water up to 23°C. This material is only approved for the mixing and curing conditions that appear on the approval. If the mixing and/or curing conditions are varied from those specified on the approval then the materials are not covered by the scope of the approval.
Page 41 of 236
We use cookies to give you the best possible experience with WRAS. Some are essential to provide website functions and ensure the website is secure. We also use cookies to help us understand how people use the site and to make improvements. Click "Accept All" to enable recommended settings or click "Manage cookies" to adjust your settings. For more details, see our Cookie Policy.