Range of basin spout outlets with brass bodies (various finishes), the outlet incorporates either a metal aerators, plastic aerators or open outlet (depending on model). Maximum working pressure 3.5 bar. Maximum operating temperature 60°C
Range of expansion vessels with EPDM membrane and stainless steel flange connections. Maximum working pressure of 10.0 bar. Maximum operating temperature 100°C.
Filling loop assemblies consisting of a brass bodied spherical valve, stainless steel braided EPDM lined flexible hose (051603F-BAGR4 model) or copper pipe (0516-ATAGBAG model) and a combined double check valve assembly incorporating a spherical valve with a DZR brass body, verified by test (suitable for backflow protection against Fluid Category 3). Maximum working pressure 10.0 bar. Maximum operating temperature 60°C
‘Unidelta Deltapress’ range of brass press-fit fittings for use with ‘Unidelta Flexall’ PE-RT/AL/PE-RT pipe. Maximum working pressure 10.0 bar. Maximum operating temperature 95°C.
Range of brass, chrome plated brass or DZR brass compression fittings for use with copper pipe only. Maximum working pressure 16.0 bar. Maximum operating temperature 85°C.
‘HE-705X & HE-715X’ ranges of brass crimp fit fittings incorporating EPDM ‘O’-rings for use with copper pipe (manufactured to EN1057-2006). HE-7052/7053/7058/7059 & HE-7152/7153/7158/7159 models also incorporate a NBR gasket. Maximum working pressure 16.0 bar. Maximum operating temperature 85°C.
VSH XPRESS Range of copper press fittings with EPDM rubber ‘O’-rings for use with copper pipe (manufactured to EN 1057). Maximum working pressure 16.0 bar. Maximum operating temperature 85°C.
Range of PVC-u solvent weld and threaded union fittings incorporating an EPDM ‘O’-ring. For use with PVC-u pipe manufactured to ISO 1452 and DIN 8063. Maximum working pressure 10.0 bar. Cold water use only.
‘Xpress’ range of press fit fittings with copper or brass bodies and EPDM ‘O’-rings. For use with copper tube manufactured to EN1057. For above ground ground use only. Maximum working pressure 16.0 bar. Maximum operating temperature 100°C.
‘Endex’ range of copper alloy and copper end feed fittings for use with copper pipe. For above ground use only. Maximum working pressure 16.0 bar. Maximum operating temperature 99°C.
Center Brand range of brass and copper end feed fittings for use with copper pipe. For above ground use only. Maximum working pressure 16.0 bar. Maximum operating temperature 99°C.
Range of WC pressure flushing valves with a solenoid valve controlling the flow. The valves are operated via an infra-red sensor or push-button assembly. The solenoid valve also incorporates a lever operated isolation valve. Maximum working pressure – 5.0 Bar. Cold water use only
Range of stainless-steel plate heat exchangers with EPDM gaskets. The primary circuit, (excluding the E2 prefix models), incorporates a drain valve and a pump (excluding STP prefix models including an ‘N’ as the 14th figure). Operating parameters: Maximum working pressure of the secondary circuit: 6.0 bar or 10.0 bar (see model). Maximum working pressure of the primary circuit: E4 models: 6.0 bar. C3, E3, E2, i2: 10.0 bar. Models added February 2023 – Econoplate STP3, STC3, STP2, STC2 & STP4: 10.0 bar. Maximum operating temperature: Primary 140°C & Secondary 85°C.
Range of under-sink, electrically heated vented water heaters (cased and insulated). Maximum operating temperature 98˚C
Range of under-sink, electrically heated vented water heaters (cased and insulated). Maximum operating temperature 98˚C
Range of gas fired condensing combination boilers providing domestic hot water via a plate heat exchanger. The cold inlet incorporates an angled spherical valve with a brass body, chromium plated brass ball and a lever operating member. The primary circuit incorporates an expansion vessel, isolation valves on flow and return, drain valve and a pressure relief valve set at 3.0 bar. Maximum working pressure of the primary circuit is 2.5 bar. Maximum working pressure of the secondary circuit is 10.0 bar. Maximum operating temperature for the secondary circuit is 55˚C. Cold supply only.
Greenstar Heatslave II range of floor standing oil-fired condensing combination boilers providing domestic hot water via a plate heat exchanger and pressurised central heating system, which incorporates an expansion vessel and pressure relief valve set at 3.0 bar. The cold water inlet incorporates a screwdriver operated spherical valve followed by a plastic flow regulator inserted within the pipework. Maximum working pressure: Primary circuit 2.5 bar. Secondary circuit 10.0 bar. Maximum operating temperature 82°C.
"Greenstar" range of indirect heat interface units and "Flow 8000" (added December 2024) range of direct heat interface units providing heating and instantaneous hot water. The heating system incorporates an expansion vessel. The products are sold with or without a prefix kit (see model), which comprises of a mounting bracket that includes spherical valves for all circuits. The "Greenstar" indirect models include a pressure relief valve (set at 3.0 bar) on the space (central) heating circuit. Greenstar models: Maximum working pressure district heating 10.0 bar. Maximum working pressure space heating 2.5 bar. Maximum working pressure secondary hot water 10.0 bar. Maximum operating temperature 60°C (secondary) and 90°C (primary). Flow 8000 models (added December 2024): Maximum working pressure district and space heating 10.0 bar. Maximum working pressure secondary hot water 10.0 bar. Maximum operating temperature 60°C (secondary) and 90°C (primary).
Range of air cooled ice making machines . Inlet is controlled via solenoid valve. Maximum working pressure 5.5 bar. Cold water use only.
Water hammer arrestor with brass body. Maximum working pressure 10.0 bar. Maximum operating temperature 90°C.
Union ball, non-return valve with a plastic PVC body. Maximum working pressure 10.0 bar. Cold water use only.
‘ECOCIRC XL N’ & ‘ECOCIRC XL PLUS N’ range of circulation pumps with stainless steel bodies, plastic impellers, and EPDM ‘O’-rings. Maximum working pressure 10.0 bar. Maximum operating temperature 85°C.
Range of vertical multistage pumps with stainless-steel bodies, stainless-steel impellers, shaft and outer sleeve. Maximum working pressures: T (oval flange): 16.0 bar. V (Victaullic & grooved), C (clamp flanges) & F (round flange) versions: 26.0 bar. Maximum operating temperature 100°C.
Range of shower rose outlets (plastic body with various finishes). The inlet incorporates a stainless-steel strainer. Maximum operating temperature 60°C. Open outlet use only.
Range of showers handsets with plastic bodies (various finishes - see model). All models incorporate a stainless steel strainer, the EcoSmart models also incorporate a plastic flow regulator. Maximum operating temperature 60°C.
Range of shower handsets with brass bodies available in various styles and finishes. The inlets incorporate an approved check valve cartridge, however, the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum operating temperature 60°C.
Range of shower handsets and shower kits. Shower kits 2.1703.391, 2.1703.015 & 2.1703.016 incorporate a shower handset, shower hose and riser rail. Shower handset inlets incorporate a flow regulator. Maximum operating temperature 60°C.
Range of shower outlets and shower kits. Shower outlets consisting of wall and ceiling mounted shower heads and hand shower. The inlets incorporate stainless steel flow regulators and approved check valve cartridges, however, the complete product has not been fully tested to demonstrate it provides backflow protection. The shower kits can consist of shower hose, shower handset, riser rail and wall outlet elbow with bracket (depending on model). Shower handset inlet incorporates a stainless-steel strainer. Both the outlet of the wall elbow and inlet of shower handset incorporates an approved check valve cartridge, however, the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum operating temperature 60°C.
Range of filter type fixed ‘shower’ outlets and shower handsets with plastic bodies. Maximum operating temperature 45°C.
Range of filter type fixed ‘shower’ outlets and shower handsets with plastic bodies. Maximum operating temperature 45°C.
‘Concept’ & ‘Advance’ ranges of atmospheric steaming ovens. The products incorporate a retractable triple layered hose on a reel and a push-button operated shower handset. The inlet of the shower handset incorporates a single check valve cartridge however, the complete product has not been fully tested to demonstrate it provides backflow protection The water supply is controlled via a solenoid valve. The retractable hose has its own dedicated supply also controlled via a solenoid valve. The products are supplied with dual layer supply hoses (grey PVC outer layer/black PVC inner layer) with ¾” captive nut end connections, and chrome plated DZR brass ½” BSP (F) x ¾” BSP (M) double check valve assemblies (suitable for backflow protection against Fluid Category 3) for installation on each inlet. Maximum working pressure 4.0 bar. Cold supply only.
Range of in-line `Y` patterned strainers with bronze bodies and stainless-steel strainer. Maximum working pressure 16.0 bar. Maximum operating temperature 100°C. Closed circuit up to 110°C
Range of flow switches with brass bodies and NBR/fibre gaskets. Maximum working pressure 10.0 bar. Maximum operating temperature 85°C.
Turbine flow sensors with a plastic bodies. Maximum working pressure 10.0 bar. Maximum operating temperature 80°C
Range of drain taps incorporating brass bodies, EPDM seats and washers and a non-rising spindle headwork. Maximum working pressure 10.0 bar. Maximum operating temperature 85°C.
Range of shower hoses available in a variety of external sheath materials and finishes (see models) with EPDM washers. Maximum operating temperature 65°C.
Range of stainless steel and brass double interlocked PEX lined flexible hose assemblies (various finishes - see model) incorporating EPDM washers. Maximum working pressure 5.0 bar. Maximum operating temperature 80°C.
Range of TPE and TPS lined flexible hose assemblies incorporating NBR ‘O’-rings and various end connections. Maximum operating temperature 60°C.
Range of PET (Polyethylene terephthalate) braided flexible hoses incorporating PEX liner and EPDM ‘O’-rings. Maximum working pressure 5.0 bar. (10.0 bar for models added September 2025). Maximum operating temperature 70°C.
Range of multi-layered flexible hoses (TPE inner liner/PVC middle/PVC outer with polyester braiding in-between) and stainless-steel braided EPDM flexible hoses. The hoses are supplied with a variety of end connections incorporating brass barbed hose inserts or white plastic barbed hose inserts. The hoses may also incorporate a servicing valve (see model). The push fit connectors are to be used with copper pipe (Manufactured to EN1057), PB pipe (Manufactured to BS EN21003) & PE-x pipe (manufactured to BS EN7291-3). Products shown with a “P” suffix (eg. WFLX15P, FLX43P) are a prepacked variant of the original product eg. WFLX15, FLX43. Products shown with a “SB” suffix (eg. FLX15P-SB, WFLX28-SB) are a reduced box quantity of an existing product. Maximum working pressure and operating temperature: 12.0 bar @ 20°C and 6.0 bar @ 65°C.
Stainless steel braided EPDM lined flexible hoses assemblies incorporating various end connections. Maximum working pressure 10.0 bar. Maximum operating temperature 85°C.
Range of wall mounted, thermostatic, shower mixers incorporating brass bodies (various finishes) 2-way ceramic disc diverter headwork to control the flow between two shower outlets with various operating members (see model). The A47203VUK model uses two ‘detent’ (push to on push to off) headworks to control the flow to each outlet. Temperature is controlled independently via a thermostatic cartridge using various operating members (see model) that also incorporates a manual override button. The inlets incorporate a combined EPDM washer and stainless-steel strainer or stainless steel strainer (A47203VUK model) and an approved check valve cartridge, however, the complete product has not been fully tested to demonstrate it provides backflow protection. The inlet of the overhead shower incorporates a combined EPDM washer and stainless-steel strainer. The products are supplied with a shower head, shower hose and handset. Maximum working pressure 10.0 Bar. Maximum operating temperature 60°C.
Wall mounted thermostatic blending valves (chromium plated brass), incorporating ceramic disc headwork with a dome type operating member and a manual diverter which diverts the flow between an over head shower and a bath. The temperature is controlled independently via a thermostatic cartridge incorporating a manual override button with a dome type operating member. The inlets incorporate stainless steel strainers and approved check valve cartridge, however, the complete product has not been fully tested to demonstrate it provides backflow protection. The spout outlet incorporates a plastic aerator. Maximum working pressure 5.0 bar. Maximum operating temperature is 60°C.
Range of wall mounted, concealed or exposed thermostatic shower valves (chromium plated brass), incorporating a single sequential headwork controlling both flow and temperature via a single lever operating member. Each inlet elbow incorporates a combined TPE washer and stainless-steel strainer. The main valve body inlets each incorporate approved check valve cartridge, however, the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum working pressure 10.0 bar. Maximum operating temperature 65°C.
Range of electronic, thermostatic mixing valves which incorporate a solenoid valve on the inlet and various outlet configurations dependant on model. All models are supplied with a user interface that controls flow and temperature. The inlets of models 1.1503.678, 1.1503.682, 1.1503.690, 1.1503.698 & 1.1621.099 incorporate a single check valve cartridge, however, the complete product has not been fully tested to demonstrate it provides backflow protection Model 1.1503.702 – Rada Sense W KIT T3 Washbasin is supplied with a wall mounted spout outlet. Model 1.1503.706 – Rada Sense S KIT T3 Shower is supplied with a fixed shower outlet. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C
Range of wall mounted thermostatic bar shower valves incorporating a thermostatic cartridge controlling the temperature with a dome operating member incorporating a manual override button. The flow to the handset or overhead shower is via a ceramic disc headwork with a dome operating member. Inlets Incorporate approved check valve cartridges, however, the complete product has not been fully tested to demonstrate it provides backflow protection. RRK models are also supplied with shower hose, handset, overhead shower head and riser rail. Maximum working pressure 5.0 bar. Maximum operating temperature 65ºC.
Ceramic disc diverter cartridge with on/off function incorporating a plastic body, NBR ‘O’-rings and silicone seals. For insertion into specifically dimensioned bores. Maximum working pressure 10.0 bar. Maximum operating temperature 95°C.
Single inlet, flow control valve with a brass body, incorporating a ‘detent’ (push to on push to off) headwork controlling the flow. The product is supplied with a trim sets in various finishes (see model) Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.
Range of adjustable, bronze in-line pressure reducing valves. Model 753A ½”, ¾” & 1” sizes and model 754A 1¼” size have inspection ports on the outlet only. Model 754A 2” and 4” sizes have inspection ports on the inlet and outlet. The valves incorporate a stainless-steel strainer. Maximum inlet supply pressure 20.0 bar. Maximum outlet pressure 1.0 bar to 4.0 bar. Maximum operating temperature 70°C.
Range of adjustable, bronze in-line pressure reducing valves. The valves incorporate a stainless-steel strainer. Maximum inlet supply pressure 20.0 bar. Maximum outlet pressure 1.0 bar to 4.0 bar. Maximum operating temperature 70°C.
Page 24 of 125
We use cookies to give you the best possible experience with WRAS. Some are essential to provide website functions and ensure the website is secure. We also use cookies to help us understand how people use the site and to make improvements. Click "Accept All" to enable recommended settings or click "Manage cookies" to adjust your settings. For more details, see our Cookie Policy.