Range of single-hole, single outlet (fixed) combination tap assemblies (brass bodies – various finishes), incorporating ceramic cartridge headworks with single lever or dome type operating members. The spout outlets are either open outlet or incorporate plastic aerators. Maximum working pressure 10.0 Bar. Maximum operating temperature 60°C.
Single hole tap(s) with a single outlet and a fixed spout. With a ceramic cartridge headworks and the spout incorporates a Flow Straightener. Product supplied with C-plate fixing type. Maximum temperature of 85 degrees Maximum pressure 5 bar.
Single hole, single outlet, fixed combination tap assemblies (brass bodies - various finishes), incorporating a ceramic cartridge headwork with a single lever operating member. The spout outlet incorporates a plastic flow straightener and an optional flow regulator. Maximum working pressure 10.0 Bar. Maximum operating temperature 85°C.
Range of floor mounted, single hole, single outlet fixed combination tap assembly (various finishes), incorporating a ceramic cartridge headwork with a single lever operating member and a self-cancelling diverter to shower outlet. The outlet to the shower incorporates an approved check valve cartridge, however the complete product has not been fully tested to demonstrate it provides backflow protection. The spout outlet incorporates an aerator. These products are not supplied with shower handset and hose. Maximum working pressure 16.0 bar. Maximum operating temperature 60°C.
Range of single hole, single outlet (swivel) combination tap assemblies (brass bodies, various finishes), incorporating a ceramic cartridge headwork with a single lever operating member and the spout outlet incorporates a plastic aerator. Maximum working pressure; 10 Bar Maximum operating temperature 60°C
| Product Identification | Surface finish | Inlet Dimension | Max Wrk. Pressure | Max Op. Temp. | Marking | Marking Location | All metals in the water pathway are on the 4msi positive list | Headwork | Fixing Type | Spout Outlet | Includes |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 1L449200DH | Matt black | 1/2" BSP (F) | 10 bar | 65 °C | WIDE | Body | No | Ceramic cartridge | Not Applicable | Aerator | Shower Hose, Handset, |
| 1L449200MA | Tri-chrome | 1/2" BSP (F) | 10 bar | 65 °C | WIDE | Body | No | Ceramic cartridge | Not Applicable | Aerator | Shower Hose, Handset, |
| 1L449200SA1 | Brushed gold | 1/2" BSP (F) | 10 bar | 65 °C | WIDE | Body | No | Ceramic cartridge | Not Applicable | Aerator | Shower Hose, Handset, |
| Product Identification | Surface finish | Inlet Dimension | Max Wrk. Pressure | Max Op. Temp. | Marking | Marking Location | All metals in the water pathway are on the 4msi positive list | Headwork | Fixing Type | Spout Outlet | Includes |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 141701 | chrome | 1/2" BSP | 10 bar | 60 °C | KINEN | on body | No | Ceramic cartridge | Aerator |
Range of wall mounted, two-hole, single outlet, fixed, combination tap assemblies (chrome plated brass bodies), incorporating quarter turn ceramic disc headworks with single lever operating members. The spout outlets incorporate plastic aerators. Products incorporate a hand shower and a manual diverter to shower outlet. Models incorporate approved check valve cartridges; however, the complete products have not been fully tested to demonstrate they provide backflow protection. Maximum working pressure: 6.0 Bar. Maximum operating temperature: 65°C.
Two-hole, single outlet (fixed) combination tap assemblies (chromium plated brass & matt black finish) incorporating a quarter turn ceramic disc headworks with single lever operating members and a manually operated diverter to shower outlet. Spout incorporates a flow straightener. Product supplied with metal backnuts Maximum temperature 65 °C Maximum pressure 10.0 bar
| Product Identification | Surface finish | Inlet Dimension | Max Wrk. Pressure | Max Op. Temp. | Marking | Marking Location | All metals in the water pathway are on the 4msi positive list | Headwork | Fixing Type | Spout Outlet | Includes |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 503109 | shower set | G3/4 | 10 bar | 60 °C | KINEN | on body | Yes | Metal Backnuts | Shower Hose, Handset, | ||
| 5593201 | shower set | G3/4 | 10 bar | 60 °C | KINEN | on body | Yes | Metal Backnuts | Shower Hose, Handset, | ||
| 143201 | shower set | G3/4 | 10 bar | 60 °C | KINEN | on body | Yes | Metal Backnuts | Shower Hose, Handset, |
Wall mounted, two hole, single outlet (fixed) combination tap assemblies (chromium plated brass), incorporating a quarter turn ceramic disc headwork with a dome type operating member. The temperature is controlled independently via a thermostatic cartridge incorporating a dome type operating member and a manual override button. Each inlet incorporates a combined NBR washer and stainless steel strainer, and an approved check valve cartridge, however, the complete product has not been fully tested to demonstrate it provides backflow protection. The spout outlet incorporates a self cancelling diverter to shower outlet and a plastic flow straightener. Maximum working pressure 10.0 bar.
Non-metallic materials and components comply with BS6920 at 65°C
| Product Identification | Surface finish | Inlet Dimension | Max Wrk. Pressure | Max Op. Temp. | Marking | Marking Location | All metals in the water pathway are on the 4msi positive list | Headwork | Fixing Type | Spout Outlet | Includes |
|---|---|---|---|---|---|---|---|---|---|---|---|
| K005* | Various | ½" captive nut | 5 bar | 65 °C | WINSDRUM | On Spout | No | Ceramic cartridge | Metal Backnuts | Aerator | Interconnecting Hoses, |
| K008* | Various | ½" captive nut | 10 bar | 65 °C | WINSDRUM | On body | No | 1/4 Turn ceramic disk | Metal Backnuts | Aerator |
* denotes finish and can be replaced by: C - Chrome RG - Rose Gold BTG - Brushed Titanium gold BZG - Brushed Zirconium gold BRG - Brushed Rose gold MW - Matte white BS - Brushed stainless BN - Brushed nickel PN - Polished nickel GM - Gunmetal B - Matte black TG - Titanium gold ZG - Zirconium gold BC - Black+chrome W - White CW - Chrome+white Q - Quartzite ZGC - Zirconium gold+chrome TGC - Titanium gold+chrome M - Medieval A - Antique bronze CP - Champagne BL - Brushed lead BP - Polished Black
| Product Identification | Surface finish | Inlet Dimension | Max Wrk. Pressure | Max Op. Temp. | Marking | Marking Location | All metals in the water pathway are on the 4msi positive list | Headwork | Fixing Type | Spout Outlet | Includes |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 20.189.002 | Various | G 1/2" | 10 bar | 65 °C | Grohe | Spout | No | 1/4 Turn ceramic disk | Not Applicable | Aerator | |
| 20.193.002 | Various | G 1/2" | 10 bar | 65 °C | Grohe | Spout | No | 1/4 Turn ceramic disk | Not Applicable | Aerator |
Where xxx denotes finish, can be replaced by: 002 – Chrome DC2 – Supersteel DA2 – Warm sunset AL2 – Brushed hard graphite A02 – hard graphit DL2 – brushed warm sunset GN2 – brushed cool sunrise A02 – hard graphite MS2 – satin steel GL2 – cool sunrise MS2 – satin graphite
Range of three hole, single outlet (fixed) combination tap assemblies, (brass bodies - various finishes). Incorporating quarter turn ceramic disc headworks and single lever operating members. The spout outlets incorporate a plastic aerator. The products are supplied with stainless steel braided EPDM lined interconnecting hoses. Maximum working pressure 10.0 Bar. Maximum operating temperature 60°C.
Range of chemical dosing equipment which incorporate self-closing valves and plastic bodies. The outlet of the injector incorporates a connection for injection of chemicals via venturi action and the inlets include stainless-steel strainers. Maximum operating pressure 9 bar. Maximum operating temperature 70°C.
Range of Socket weld, Click weld, Butt weld and Electro fusion fittings (see models), for use with ABN//INSTAL CT Faser RD Series 3.2 / SDR 7.4 & ABN//INSTAL CT Faser RD Series 5 / SDR 11 pipe. Maximum working pressure; (see models) Maximum operating temperature; (see models)
Range of stainless steel (SS304 or SS316L) press-fit fittings incorporating EPDM ‘O’-rings for use with *‐KJ600304 and *-KJ600316 stainless steel pipes. The "KJ6278" prefix models also incorporates an EPDM gasket on the union nut. Jointing is achieved via a crimping tool using a ‘M’ profile. For above and below ground use. Maximum working pressure 16.0 bar. Maximum operating temperature 85°C.
Range of brass compression fittings for use with copper pipes (manufactured to EN 1057). For above ground use only. Maximum working pressure 16.0 bar. Maximum operating temperature 85°C.
Flange fittings with TP2 copper bodies, for use with TP2 copper pipe to EN1057. Above ground use only. Maximum working pressure 16.0 bar. Maximum operating temperature 85°C.
Range of ‘M’ profile copper press fittings with EPDM ‘O’-rings for use with copper pipes (manufactured to EN 1057). Jointing is achieved via a crimping tool using a ‘M’ profile. For above and below ground use. Maximum working pressure 20.0 bar. Maximum operating temperature 85°C.
'Flomasta’ range of push-fit fittings with PEX-b, polysulphone or PPE bodies, supplied with polysulphone inserts. For use with PEX pipe (manufactured to BSEN 7291 part 3), PB (manufactured to BSEN 7291 part 2) and copper pipe (EN1057). Maximum working pressure/temperature: 12.5 Bar @ 20°C. As of October 2025: Maximum working pressure/temperature 3 Bar @ 92°C.
Range of end feed copper fittings for use with copper pipes (manufactured to EN 1057). The 5043G series and 5002G series models incorporate an EPDM ‘O’-ring on the captive nut connection. For above and below ground use. Maximum working pressure 20.0 bar. Maximum operating temperature 85°C.
Dual flush, WC outlet valves. The valves are operated via a push button assembly for either full or reduced flush and incorporates an internal overflow. Cold water use only.
Range of dual flush, WC outlet valves. Each valve is operated via a push button assembly for either full or reduced flush and incorporates an internal overflow. Cold water use only.
Electric instantaneous, vented, mains water heater. Maximum operating temperature 98°C.
Range of ultrasonic dry type water meters with brass bodies. Maximum working pressure 16.0 Bar. Maximum operating temperature 50.0°C.
‘BECO Y’ range of ultrasonic water meters with plastic bodies, plastic transducers and silicone ‘O’-rings. The inlet incorporates a plastic strainer. Maximum working pressure 16.0 bar. Maximum operating temperature 85°C.
Range of brass bodied threaded fittings and a brass end feed fitting (C04069H00081A model only). The CL08069H192B4 model is chrome plated. The C04069H00081A model end feed fitting is for use with copper pipe (manufactured to EN 1057). The C04149H00191A model incorporates a plastic flow straightener. Maximum working pressure 10.0 bar, except for the C04149H00190A and C04149H00191A models which are open outlet use only. Maximum operating temperature 85°C.
Threaded adaptor (brass body) soldered with copper pipe and a range of thread extensions (chrome plated brass bodies). Maximum working pressure 16.0 bar. Maximum operating temperature 85°C.
Range of threaded fittings with either brass or chrome plated brass bodies. Maximum working pressure 40 Bar Maximum operating temperature 85°C.
CM(E) range of electronically operated pumps available in stainless steel, (‘EN 1.4301/AISI304’ or ‘EN 1.4401 /AISI316’) and cast iron. The pumps are supplied with Sic-Sic mechanical shaft seals and FKM or EPDM seals. Maximum operating parameters: Cast iron models: Maximum working pressure 6.0 bar @ 90°C. Maximum working pressure 10.0 bar @ 40°C. Stainless steel models (not self-priming variants): Maximum working pressure 10.0 bar @ 99°C. Maximum working pressure 16.0 bar @ 90°C. Stainless steel self-priming models (CM(E) 1, 3 & 5 (AISI 304) only): Maximum working pressure 10.0 or 16.0 bar @ 60°C.
| Product Identification | Surface finish | Inlet Dimension | Max Wrk. Pressure | Max Op. Temp. | Marking | Marking Location | All metals in the water pathway are on the 4msi positive list | Headwork | Fixing Type | Spout Outlet | Includes |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 26.477.xxx | Various | G 1/2" | Open Outlet bar | 65 °C | Grohe | Shower faceplate | No | Fixed Head, |
Where xxx denotes finish, can be replaced by: 000 – Chrome DC0 – Supersteel DA0 – Warm sunset LS0 – moon white AL0 – Brushed hard graphite DL0 – brushed warm sunset GN0 – brushed cool sunrise GL0 – cool sunrise MG0 – satin graphite MS0 – satin steel A00 – hard graphite BE0 – polished nickel EN0 – brushed nickel
Range of shower handsets with ABS bodies (various finishes, see model). The spray outlet is either multifunction or single function depending on series. Open outlet use only. Maximum operating temperature 60°C.
Range of wall mounted or ceiling mounted shower arms with brass bodies (various finishes - see model). Maximum operating temperature 65°C.
Stainless-steel, angled, wall mounted overhead shower, incorporating silicone nozzles. Maximum operating temperature 85°C.
Range of In-line Y patterned strainers with ductle iron bodies (blue epoxy powder coated) and stainless-steel mesh. Maximum working pressure: 16 Bar Maximum operating temperature: 85 °C
Range of in-line Y pattern strainers with bronze bodies, forged brass cap and stainless- steel screen. Threaded end connections to BS21 ISO7/1 r/c (BSP taper – JIS B0203) Maximum working pressure 25 bar. Maximum operating temperature 23˚C.
Range of drain taps with a brass body (some models chrome plated) and rising spindle headwork. Maximum working pressure 16.0 bar. Maximum operating temperature 85°C.
Range of wall mounted hose union taps incorporating a brass body with a non-rising spindle headwork and a T type operating member. The BBFHUB-D – ½” model incorporates two approved single check valve cartridges (one on the inlet, one on the outlet), however the complete product has not been fully tested to demonstrate it provides backflow protection. Product incorporates a drain plug after the inlet check valve cartridge. Maximum working pressure 10.0 bar. Maximum operating temperature 80°C.
| Product Identification | Surface finish | Inlet Dimension | Max Wrk. Pressure | Max Op. Temp. | Marking | Marking Location | All metals in the water pathway are on the 4msi positive list | Headwork | Fixing Type | Spout Outlet | Includes |
|---|---|---|---|---|---|---|---|---|---|---|---|
| M3401 X XXX | VARIOUS | 1/2” BSP | 10.0 bar | 65 °C | PPI | REAR OF BODY | No | 1/2 Turn ceramic disk | Metal Backnuts | Aerator & Flow Straightener | Flow Regulator Fitted, |
X XXX Denotes the following: First X: Different handle option and the second, third & fourth XXX for different finishes: Handles: A – Single lever type Chrome – No suffix, brushed brass – BGP, PVD Gold – PVD, Brushed Nickel – BN1, Gun Metal – GMG, Matt Black – MBK, Matt White – MWH, Stainless Steel – SS1, Black Chrome – BCP, Titanium – TIB and Antique Bronze – AB1
Range of pillar taps (chrome plated brass bodies) incorporating quarter turn ceramic disc headworks with single lever operating members and flow regulator in the inlet (1/2” only). The spout outlets incorporate a plastic flow straightener. The product is supplied with metal back nuts. Maximum working pressure: 10.0 Bar Maximum operating temperature: 85°C
Deck mounted pillar tap (chrome plated brass body) incorporating quarter turn ceramic disc headwork with a dome type operating member. The spout outlet incorporates a plastic aerator. Maximum working pressure 10.0 Bar Maximum operating temperature 60.0°C
Range of shower hoses, multi-layered hose (various external finishes) with PVC inner liner, brass end connections. Open outlet use only. Maximum operating temperature 60°C.
Range of chromium plated stainless steel or brass interlocked shower hoses with an optional PVC outer layer. Incorporating either a PVC or TPE inner hose and EPDM gaskets. Maximum operating temperature 60°C.
Range of Stainless-Steel braided EPDM lined flexible hose assemblies with various end connections. For use with copper pipe manufactured to EN1057 Maximum working pressure; 16 Bar Maximum operating temperature; 85°C
Range of stainless-steel braided EPDM lined flexible hose assemblies with a variety of end connections. Some models incorporate push-fit isolation valves. Compression connection to be used with DM LLDPE pipes or PEX barrier pipe manufactured to BS7291-3. Maximum working pressure and maximum operating temperature 12 bar @cold water use only & 7 bar @ 65°C.
‘DG10E PF series’ of stainless steel braided EPDM lined flexible hose assemblies with EPDM ‘O’-rings or gaskets available with a variety of end connections. The DN10 bore 15mm push fit connection is also available with a screwdriver operated isolation valve. Push-fit connections are for use with copper pipes (manufactured to EN 1057) and PEX pipes (manufactured to BS 7291-3). Maximum working pressure 10.0 bar. Cold water use only.
‘FS4E Series’ 2 port, 3 port and 4 port nickel plated brass manifolds incorporating stop valves. The models include white operating members with either red, green or blue indices. Maximum working pressure 10.0 bar. Maximum operating temperature 95°C.
Range of automatic air release valves with blue epoxy coated cast iron bodies and plastic floats. Maximum working pressure 10.0 Bar 16.0 Bar, 25.0 Bar (see models) Maximum operating temperature 60.0°C
Range of wall mounted thermostatic shower valves, (brass bodies - various finishes), incorporating a thermostatic cartridge controlling the temperature. Supplied with either single lever or cross top operating members depending on model and with a manual override button. The inlets incorporate stainless steel strainers and approved check valve cartridges, however, the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum working pressure 5.0 bar. Maximum operating temperature 85ºC.
Page 187 of 209
We use cookies to give you the best possible experience with WRAS. Some are essential to provide website functions and ensure the website is secure. We also use cookies to help us understand how people use the site and to make improvements. Click "Accept All" to enable recommended settings or click "Manage cookies" to adjust your settings. For more details, see our Cookie Policy.