Range of medical sterilised water filter cartridges with plastic bodies and EPDM ‘O’-Rings. Models SMTFW-SLSS / SMTFD-SLSS incorporate a check valve cartridge on the inlet, however, the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum Working Temperature: 50°C.
Range of filter cartridges. Maximum working pressure 8.0 Bar. Cold water use only.
Range of press copper crimp fittings with EPDM ‘O’-rings for use with copper tube manufactured to EN 1057. The joints are achieved by means of a crimping tool. For above ground use. Maximum working pressure: 16.0 bar. Maximum operating temperature: 85°C
Range of MULTITUBO tin-plated brass and PPSU press fit fittings for use with MULTITUBO multi layered PE-RT/AL/PE-RT pipe. Maximum working pressure 10.0 bar. Maximum operating temperature 70°C.
‘BORPLUS’ range of PP-RCT Socket Fusion fittings used with ‘BORPLUS PP-RCT FASER COMPOSITE STABIL’ pipe. Maximum working pressures at 16.0 Bar @ 23°C and 6.0 Bar @ 85°C.
Flowtech range of green butt welded polypropylene fittings for use with Flowtech’ PPRGF or PPR pipes. Maximum working pressure 20.0 bar. Cold water use only.
‘Hansen easy fit’ range of polypropylene compression fittings with EPDM ‘O’-rings for use with metric PE80 (20mm-63mm) and PE100 (32mm-110mm) pipe to AS/NZS:4130 and plastic pipe inserts. For above and below ground use. Maximum working pressure: See models. Maximum operating temperature: Cold water use only.
Range of ‘Isiflo Sprint’ push fit fittings for use with PE100 pipe (manufactured in accordance with EN 12201), for above and below ground use. Isiflo Sprint Family fittings can be installed with seal liners, support liners and without any liner. Maximum working pressure 16 bar. Cold water use only.
Allpex range of end feed capillary fittings and brazing fittings for use with copper tube (manufactured to BS EN 1057). EG fittings have gunmetal bodies, ED fittings have DZR brass bodies & EB fittings have brass bodies. For above ground use only. Maximum working pressure: 6mm – 34mm 25Bar, 34mm -54mm 25Bar, 54mm – 108mm 16Bar, 108mm – 159mm 5 Bar. Maximum operating temperature 30°C
Range of WC dual flush drop valves with plastic bodies and silicone seals. The valves are operated via a two push button assembly for either full or reduced flush and incorporate an internal overflow. Cold water use only.
WC dual flush drop valve with ABS body and silicone seals. The valve is operated via a two push button assembly for either full or reduced flush and incorporates an internal overflow. Cold water use only.
Range of WC dual flush drop valves operated via a two-push button assembly for either full or reduced flush and incorporates an internal overflow. Cold water use only.
Range of wall mounted, electronic tap assemblies which are set within a mirrored cabinet unit. The flow is controlled by a solenoid valve assembly and is activated via infra-red non touch operation. The units also incorporate a soap dispenser and hand dryer or paper towel dispenser. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C
Indirect heat interface unit with copper brazed, stainless-steel heat exchangers, providing heating and instantaneous hot water. The product incorporates an expansion vessel on the cold-water supply to the plate heat exchanger and a safety relief valve on the heating circuit set @ 2.5 bar. The DHW and heating circuits are both fitted with drain valves incorporating cover caps. Maximum working pressure 16 Bar (Primary), 10 Bar (DHW) & 3 Bar (Heating) Maximum operating temperature 95°C
Ultrims Ultrasonic range of in-line water meters with brass or plastic (-01 suffix models) bodies. Maximum working pressure 16.0 bar. Maximum operating temperature 50°C.
Range of water meters with brass bodies and plastic turbines. The inlet incorporates a plastic filter. Maximum working pressure 16.0 bar. Maximum operating temperatures Sizes DN15-25 models: 50°C, sizes DN32-40 models: 85°C.
Range of in-line water meters with brass bodies. Maximum working pressure 16.0 bar. Maximum operating temperature 50°C.
Range of water meters with brass bodies, plastic turbines and plastic strainers on inlets. Maximum working pressure 16.0 bar. Maximum operating temperature 85°C
Range of submersible pressure sensors and hydrostatic transmitters (supplied in lengths up to 1000m). Cold water use only.
Hydraulic circuit used to control the water path within the heating and sanitary boiler, with plastic body incorporating filter, flow regulator, plate heat exchanger and EPDM O-rings. Maximum working pressure 7.0 bar. Maximum operating temperature 85°C.
Concealed, floor mounted basic set with DZR brass body. For use with floor standing combination tap assemblies. Maximum operating pressure 10 bar. Maximum operating temperature 70°C
Peripheral pump for mains water applications with a brass body and impeller, . The pushfit connections on the hoses are for use with copper pipe (manufactured to EN 1057). Maximum working pressure 6.0 bar. Cold water use only.
‘Monsoon Standard’ range of single and twin ended shower booster pumps with brass bodies, brass impellers, EPDM seals and NBR ‘O’-rings. The inlet(s) of the pump body incorporate(s) a plastic strainer. Models with push fit connections include an integral isolation valve. Pushfit connections are for use with copper pipe (manufactured to EN 1057). Maximum working pressure 6.0 bar. Maximum operating temperature 65°C.
Range of horizontal or vertical multi-stage pumps with a stainless-steel body (HM models) or cast iron body with blue coloured cationic resin coating (VM models), incorporating either plastic or stainless-steel impellers (see model), stainless steel sleeve, EPDM gaskets and seals. Maximum working pressure 10.0 bar / 16.0 bar (see models). Cold water use only.
Range of single or twin shower pumps with brass bodies, brass impeller supplied with flexible connection hoses that incorporate servicing valves. Maximum Working pressure 6 Bar Maximum operating temperature 65°C
‘Hydro MPC’ range of booster sets incorporating vertical multistage centrifugal pumps, butterfly valves, non-return valves (not suitable for backflow protection), pressure transmitters, pressure gauges, lever operated spherical valves, stainless steel blanking flanges and fibre/NBR gaskets. Maximum working pressure 16.0 bar. Cold water use only. ‘Hydro MPC’ range of booster sets incorporating vertical multistage centrifugal pumps, butterfly valves, non-return valves (not suitable for backflow protection), pressure transmitters, pressure gauges, lever operated spherical valves, stainless steel blanking flanges and fibre/NBR gaskets. Maximum working pressure 16.0 bar. Cold water use only.
Range of plastic shower handsets available in various finishes. Maximum operating temperature 65°C.
Concealed, wall mounted elbow fitting with a brass body incorporating EDPM `O`-rings. Maximum working pressure: 10.0 Bar. Maximum operating temperature: 70.0°C.
Range of in-line Y patterned strainers with flanged ductile iron bodies (blue epoxy coated) and stainless-steel mesh strainers. The strainers also incorporate a drain plug. Maximum working pressure 16.0 bar. Maximum operating temperature 85°C.
Range of in-line Y patterned strainers with flanged ductile iron bodies (blue epoxy coated) and stainless-steel mesh strainers. The strainers also incorporate a drain plug. Maximum working pressure 16.0 bar. Maximum operating temperature 85°C.
A Range of drain valves with bronze bodies incorporating brass bonnets, stems and baffles with EPDM seats and O’-rings. The products incorporate a rising spindle operating mechanism. Maximum working pressure 16.0bar. Maximum operating temperature 85°C.
Range of draining taps with DZR brass bodies. Incorporating a rising spindle headwork, EPDM or NBR seals and washers. Maximum working pressure 16.0 bar.
Non-metallic materials and components comply with BS6920 at 85°C
Range of drain taps with brass body and rising spindle headwork. Maximum working pressure 16.0 bar. Maximum operating temperature 85°C.
Range of drain taps with brass or DZR brass body (some models chrome plated) and rising spindle headwork. Maximum working pressure 16.0 bar. Maximum operating temperature 85°C.
Range of drain valves with a brass bodies, spindle and EPDM ‘O’-rings. Maximum working pressure 16.0 bar. Maximum operating temperature 99°C.
Self-closing combination tap assembly (chromium plated brass) with a spring-loaded headwork controlling both temperature and flow with a dome type operating member. The spout outlet incorporates a plastic flow straightener. The flexible hose inlets incorporate a combined EPDM washer and stainless-steel strainer, as well as an approved check valve cartridge however, the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum working pressure 10.0 bar. Maximum operating temperature 65°C.
Range of stainless-steel braided TPS lined flexible hose assemblies incorporating EPDM or fibre washers. The products can be supplied with a range of end connections and seals. Some models also incorporate integral isolation valves Push-fit fittings for use with: Copper Pipes manufactured in accordance with BS EN 1057 PB pipes manufactured in accordance with BS 7291-2 PEX pipes manufactured in accordance with BS 7291-3 Maximum working pressure 12.0 bar. Maximum operating temperature 65°C.
‘Qualflex Excel’ range of stainless steel over braided, PEX lined flexible hoses, incorporating EPDM or fibre washers. The products can be supplied with a range of end connections and seals. Some models also incorporate integral isolation valves. Push-fit fittings for use for with: Copper Pipes manufactured in accordance with BS EN 1057 Plastic PB pipes manufactured in accordance with BS 7291-2 Plastic PEX pipes manufactured in accordance with BS 7291-3 Maximum working pressure: 6.0 bar. Maximum operating temperature: 65°C.
Range of stainless-steel braided EPDM lined flexible hose assemblies with EPDM seals, available with a variety of end connections, some of which include isolation valves (see model). Maximum working pressure 10 Bar. Maximum operating temperature 85°C
Range of Indirect and direct unvented storage cylinders. The secondary circuit is factory fitted with a temperature and pressure relief valve set at 6.0 bar at 90˚C and an expansion relief valve set at 4.5 bar. The product is supplied with a safety group consisting of a pressure reducing valve set at 3.0 bar, and an approved check cartridge, verified by test (suitable for backflow protection against fluid category 2) an expansion vessel and tundish. Maximum working pressure: Secondary: 4.0 Bar Primary: 3.0 Maximum operating temperature 99.0°C
Range of primary hot water buffer tanks consisting of stainless steel shells. Maximum working pressure 8.0 bar. Maximum operating temperature 80°C.
Range of primary hot water buffer tanks consisting of insulated enamel and Stainless steel shells. Maximum working pressure 8.0 bar. Maximum operating temperature 80°C.
Range of unvented storage cylinders. The secondary circuit is factory fitted with a temperature and pressure relief valve set at 6.0 bar at 95˚C and an expansion relief valve set at 4.5 bar. The product is supplied with a safety group consisting of a pressure reducing valve set at 3.0 bar, and an approved check valve cartridge, however, the complete product has not been fully tested to demonstrate it provides backflow protection). Also supplied with an expansion vessel and tundish. Maximum working pressures: Secondary circuit: 4.0 Bar Primary Circuit: 3.0 Bar Solar circuit: 6.0 Bar Maximum operating temperature 99.0°C
Range of unvented storage cylinders. The secondary circuit is factory fitted with a temperature and pressure relief valve set at 6.0 bar at 95˚C and an expansion relief valve set at 4.5 bar. The product is supplied with a safety group consisting of a pressure reducing valve set at 3.0 bar, and an approved check valve cartridge, however, the complete product has not been fully tested to demonstrate it provides backflow protection. Also supplied with an expansion vessel and tundish. Maximum working pressures: Secondary circuit: 4.0 Bar Primary Circuit: 3.0 Bar Solar circuit: 6.0 Bar Maximum operating temperature 99.0°C
Range of unvented storage cylinders. The secondary circuit is factory fitted with a temperature and pressure relief valve set at 6.0 bar at 95˚C and an expansion relief valve set at 4.5 bar. The product is supplied with a safety group consisting of a pressure reducing valve set at 3.0 bar, and an approved check valve cartridge, however, the complete product has not been fully tested to demonstrate it provides backflow protection. Supplied with an expansion vessel and tundish. Maximum working pressures: Secondary circuit: 4.0 Bar Primary Circuit: 3.0 Bar Solar circuit: 6.0 Bar Maximum operating temperature 99.0°C
Range of unvented storage cylinders. The secondary circuit is factory fitted with a temperature and pressure relief valve set at 6.0 bar at 95˚C and an expansion relief valve set at 4.5 bar. The product is supplied with a safety group consisting of a pressure reducing valve set at 3.0 bar, and an approved check valve cartridge, however, the complete product has not been fully tested to demonstrate it provides backflow protection. Supplied with an expansion vessel and tundish. Maximum working pressures: Secondary circuit: 4.0 Bar Primary Circuit: 3.0 Bar Solar circuit: 6.0 Bar Maximum operating temperature 99.0°C
Range of air venting valves incorporating an epoxy coated, iron body and a drain point. Maximum working pressure 16.0 bar. Maximum operating temperature 60˚C.
‘Rada’ electronically controlled thermostatic blending valve, with a stainless-steel body, EPDM ‘o’ rings and seals. Maximum working pressure; 13.8 Bar. Maximum operating temperature 85°C.
Range of wall mounted thermostatic bar shower mixers, (chrome plated brass bodies), incorporating a ceramic disc diverter cartridge controlling the flow with a dome type operating member. The temperature is controlled independently with a thermostatic cartridge with a dome type operating member that incorporates a manual override button. The inlets incorporate stainless steel strainer washers, approved single check valve cartridges, however, the complete product has not been fully tested to demonstrate it provides backflow protection and screwdriver operated isolation valves. The products are supplied with a shower hose, handset, riser rail assembly and an overhead shower outlet. Maximum working pressure 10.0 bar
Non-metallic materials and components comply with BS6920 at 65°C
Range of wall mounted thermostatic bar shower mixers, (chrome plated brass bodies), incorporating a ceramic disc diverter cartridge controlling the flow with a dome type operating member. The temperature is controlled independently with a thermostatic cartridge with a dome type operating member that incorporates a manual override button. The inlets incorporate stainless steel strainer washers, approved single check valve cartridges, however, the complete product has not been fully tested to demonstrate it provides backflow protection and screwdriver operated isolation valves. The products are supplied with a shower hose, handset, riser rail assembly and an overhead shower outlet. Maximum working pressure 10.0 bar
Non-metallic materials and components comply with BS6920 at 65°C
Page 12 of 28
We use cookies to give you the best possible experience with WRAS. Some are essential to provide website functions and ensure the website is secure. We also use cookies to help us understand how people use the site and to make improvements. Click "Accept All" to enable recommended settings or click "Manage cookies" to adjust your settings. For more details, see our Cookie Policy.