‘X086 Ceramic Dome’. Grey coloured, hydraulically pressed ceramic dome component. For use with water up to 23°C.
'GCF-SRC'. Factory applied, grey coloured cement mortar. Mix sand, cement and water in a ratio of 4:2:1 and apply as per manufacturer's instructions 'QC-WI-8.1.8, revision 2/0, issue date 30/10/2021'. Cure for 28 days@24°C. For use with water up to 65°C. This material is only approved for the mixing & curing conditions that appear on the approval. If the mix and/or cure conditions are varied from those specified on the approval then the material is not covered by the scope of the approval.
'RF (Riyadh Foundry)'. Factory applied, grey coloured cement. Mix cement, sand and water in a 1:1.5:0.6 weight ratio and apply as per manufacturer's work instruction 'WI.PR.07', revision '01/01/', dated '16.02.2022'.. Cure for 3 hours@25°C. For use with water up to 85°C. This material is only approved for the mixing and curing conditions that appear on the approval. If the mix and/or cure conditions are varied from those specified on the approval then the material is not covered by the scope of the approval.
‘Promag’. Factory applied, black coloured PUR coating system comprising of a primer and topcoat. ‘Promag Primer’ is a two-part primer to be mixed in a 1:2 mass ratio before applying as per manufacturer’s core instructions ‘TLB: 10000043811’, ‘Version: M’. Cure/dry for 2 hours@23°C. ‘Promag Topcoat’ is a three-part topcoat to be mixed in a 92.59:5.19:2.22 mass ratio before applying as per manufacturer’s core instructions ‘TLB: 10000043811’, ‘Version: M’. Cure/dry for 20 seconds@20-26°C. For use with water up to 23°C. This material is only approved for the mixing and curing conditions that appear on the approval. If the mix and/or cure conditions are varied from those specified on the approval then the material is not covered by the scope of the approval.
'Weberdry epo PW'. Site applied, light grey coloured (once mixed), two-component epoxy coating. Mix Part A (light grey coloured) with Part B (translucent, yellow coloured) in a weight ratio of 100:20. Apply as per manufacturer's TDS 'Edition: 04.23-A'. Cure for 24 hours@25°C. Mix and apply a second coat in the same way and then cure for 14 days@25°C. For use with water up to 23°C. This material is only approved for the mixing and curing conditions that appear on the approval. If the mix and/or cure conditions are varied from those specified on the approval then the material is not covered by the scope of the approval.
'TUSIL® ACQUA HT & TUSIL® ACQUA'. Multi-layered hoses comprising of a white coloured, silicone rubber inner layer, white coloured silicone rubber/polyester middle layer and blue coloured outer layer. The hose is made by vulcanisation on rigid mandrel. For use with water up to 85°C.
‘Multitubo’ multi-layered pipe. Extruded, triple layered pipe consisting of a white coloured, translucent PE-RT inner layer, aluminium middle layer and white coloured, opaque PE-RT outer layer. For use with water up to 85°C.
'Drincable'. Blue coloured, extruded, EPDM rubber electrical cable. Shore hardness 50. Tested in-radius size 0.90mm. For use with water up to 23°C. This approval is for complete cable, the blue coloured outer part being the water contact layer.
‘Palaplast Hydropal W PE80 & PE100 pipes’. Extruded, PE80 & PE100 pipes, both available in either blue colour or black colour (with blue stripe). All pipes are for use with water up to 23°C.
'Titan A202'. Site applied, pale yellow coloured hydrophilic polyurethane foam. Apply as per manufacturer's Tech Sheet '03', dated '10.01.2023' and spray treated surface with water. Cure for 6 hours at an ambient temperature (19-21°C). For use with water up to 23°C. This material is only approved for the curing conditions that appear on the approval. If the cure conditions are varied from those specified on the approval then the material is not covered by the scope of the approval.
`SW EPDM`. Black coloured, extruded, EPDM hose. Shore hardness 85. Tested in-radii sizes between 0.75mm & 1.70mm. For use with water up to 85°C.
'Supercast PVC Waterstop Hydrofoil'. Blue coloured, extruded PVC waterstop. For use with water up to 23°C. These materials are for use in concrete reservoirs and similar structures, constructed in accordance with the design criteria of BS EN 1992 with respect to normal frequency of joints. The materials have been tested at a reduced surface area to volume ratio of 1000mm² per litre as specified in BS 6920: Part 1
'TamPur 150'. Site applied, Hydrophilic polyurethane foam which is an amber coloured liquid when unreacted and a pale yellow coloured, flexible foam material when cured. Mix TamPur 150 with water in a volumetric ratio of 1:1 and apply as per manufacturer’s TDS 'V1UK19 – 2019.4.25'. Cure for 24 hours at 7°C. For use with water up to 23°C. This material is only approved for the mixing & curing conditions that appear on the approval. If the mix and/or cure conditions are varied from those specified on the approval then the material is not covered by the scope of the approval. These materials are for use in concrete reservoirs and similar structures, constructed in accordance with the design criteria of BS EN 1992-3:2006 (Design of concrete structures – Liquid retraining and containing structures) with respect to normal frequency of joints. The material has been tested at a reduced surface area to volume ratio of 1000mm² per litre.
'Durapipe FIP & Astore PVCu Clear Solvent Cement'. Clear, colourless solvent cements. Apply as per manufacturer's instructions and cure/dry for 24 hours@5°C. For use with water up to 23°C. This material is only approved for the curing conditions that appear on the approval. If the cure conditions are varied from those specified on the approval then the material is not covered by the scope of the approval.
Single hole, triple outlet (swivel) combination tap assembly (brass bodies, various finishes - see model), incorporating a ceramic cartridge headwork with single lever operating member. Electronic controls allow the tap to dispense boiling, chilled or sparkling water. The vented models are supplied with a brass adaptor containing a plastic flow regulator and a combined EPDM washer and stainless-steel strainer, for installation on the mains cold water into the ceramic cartridge. They are also supplied with a stainless steel braided PEX lined flexible hose assembly and a stainless steel braided TPSiV lined flexible hose assembly both with ½” captive nut end connections for installation between the tap and a command centre, (which is not included as part of this approval). Maximum working pressure 5.0 bar. Maximum operating temperatures: Near boiling water circuit: 100°C. Ambient hot and cold (mixed) circuit: 65°C. Chilled/Chilled and sparkling circuit: Cold water use only.
Range of single hole, single outlet, electronically controlled tap assemblies (brass body – various finishes). The flow is controlled via a solenoid valve and activated by an infra-red sensor on the front of the spout. The spout outlet incorporates a plastic aerator. Models xxx.yyy.170E/W are supplied with a click clack waste. Maximum working pressure 5.0 bar.
Non-metallic materials and components comply with BS6920 at 60°C
Range of inlet control valves with DZR brass bodies incorporating a pressure reducing valve (set at 1.5, 1.8. 2.0, 2.1, 3.0 or 3.5 depending on model) and a pressure relief valve (set at 3.0, 3.5, 4.5, 5.0. 6.0 or 8.0 depending on model. All models incorporate a stainless-steel mesh and an approved check valve cartridge however, the complete product has not been fully tested to demonstrate it provides backflow protection. Model CWIC355040 comes supplied with a tundish. For use with copper pipe to BS EN 1057, PB pipe (with inserts) to BS EN 7291-2:2010 and PEX pipe (with inserts) to BS EN 7291-3:2010. Maximum working pressure 16.0. Maximum operating temperature of 25°C.
WC flushing cistern incorporating a side entry BS 1212-4 compact type float operated inlet valve providing a Type AG air gap with a dual flush drop valve for full flush volumes of up to 6 litres and a reduced flush of up to 4 litres. The cistern is operated by a manual push button and incorporates a servicing valve on the inlet supply. Maximum working pressure 10.0 bar. Cold water use only.
Concealed WC flushing cisterns incorporating a side entry compact type float operated inlet valve providing a Type AG air gap with a dual flush drop valve for full flush volumes of up to 6 litres and a reduced flush of up to 4 litres. The cistern is operated by an electronically controlled flush valve. Maximum working pressure 10.0 bar. Cold water use only
WC flushing cistern incorporating a side entry BS 1212-4 compact type float operated inlet valve providing a Type AG air gap with a dual flush drop valve for full flush volumes of up to 6 litres and a reduced flush of up to 4 litres. The cistern is operated by electronic or manual actuation. Maximum working pressure 10.0 bar. Cold water use only
Range of break tanks and pump sets incorporating a Type AB airgap (verified by test - suitable for backflow protection against fluid category 5). Maximum working pressure 10 bar. Cold water use only.
Range of tundishes incorporating a black or grey plastic body or mild steel painted black body (128-2001 CST, 128-2003 CST, 128-2004 CST & 128-2005 CST models only). Maximum operating temperature 85°C.
Tundish with a black plastic body and a straight through pattern. The product satisfies the requirements of an air gap to drain. Maximum operating temperature 65°C.
Range of dry trap tundishes with plastic bodies incorporating a spring-loaded diaphragm on the outlet. Maximum operating temperature 85°C
Range of single hole, single outlet (fixed) combination tap assemblies (brass bodies – various finishes), incorporating a ceramic cartridge headwork and single lever operating member. The spout outlet incorporates a plastic aerator. Supplied with a click type waste. Maximum working pressure 5.0 Bar
Non-metallic materials and components comply with BS6920 at 60°C
Single hole, single outlet (swivel) combination tap assemblies (chromium plated brass body), incorporating quarter turn ceramic disc headworks with single lever operating members. The spout outlet incorporate a plastic flow straightener or plastic aerator. Maximum working pressure 10.0 bar. Maximum operating temperature 65˚C.
Range of two-hole, single outlet fixed combination tap assemblies (brass bodies - various finishes, see model), incorporating quarter turn ceramic disk headworks with single lever operating members. The spout outlet incorporates a plastic aerator. The products are supplied with metal backnuts. Maximum working pressure 5.0 bar. BS6920 60°C.
Range of two-hole, single outlet (fixed) combination tap assemblies (chromium plated brass), incorporating a quarter turn ceramic disc headwork with single lever operating members and a manual diverter to shower outlet. The spout outlet incorporates a plastic aerator. The products are supplied with metal back nuts, shower hose and handset. Maximum working pressure 5.0 Bar
Non-metallic materials and components comply with BS6920 at 60°C
Range of five-hole, single outlet (fixed) combination tap assemblies with brass or stainless steel bodies in various finishes. The products incorporate a ceramic cartridge headwork controlling both the temperature and flow to the shower handset, and a quarter turn ceramic disc headwork controlling the flow via a thermostatic cartridge to the spout outlet. All have single lever operating members. Some models are supplied with a spout outlet which incorporates a plastic aerator. Some models are supplied with a shower hose and handset. The inlet to the spout assembly and the inlet of the shower handset each incorporate a single check valve cartridge however, the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.
Range of single hole, single outlet (fixed) combination tap assemblies (various finishes - see model). Electronic controls on the left-hand side of the body allow the tap to dispense one or more of the following (model specification dependent): ambient, near boiling, chilled or sparkling water. The spout incorporates a plastic aerator on the Sparkling/Ambient/Chilled outlet, and a separate outlet for the near boiling water. All models incorporate a vent outlet within the tap spout for the near-boiling water circuit. Near-boiling circuit has a maximum operating temperature of 98°C. All other circuits have a maximum operating temperature of 65°C.
Range of single hole, single outlet (fixed) combination tap assemblies (various finishes - see model). Electronic controls on the left-hand side of the body allow the tap to dispense one or more of the following (model specification dependent): boiling, chilled or sparkling water. Ambient (hot and cold) water is controlled via a ceramic cartridge headwork with a single lever operating member. The spout incorporates a plastic aerator on the Sparkling/Chilled and the Ambient outlet, and a separate outlet for the boiling water. Both model ranges incorporate a vent outlet within the tap spout for the boiling water circuit. Maximum working pressure 5.0 bar (Ambient (hot and cold) circuit only). 95458xxx models - Boiling circuit has a maximum operating temperature of 100°C. All other circuits have a maximum operating temperature of 65°C. 95459xxx models - Boiling circuit has a maximum operating temperature of 100°C. The ambient circuit has a maximum operating temperature of 65°C. The chilled/sparkling circuit has a maximum operating temperature of 60°C.
Zilmet range of cylindrical or tubular expansion vessels, epoxy coated carbon steel bodies with either Butyl or EPDM membranes and stainless-steel or galvanized carbon-steel connections. Please refer to models for maximum working pressures, as this varies by model and size. Maximum operating temperature 65°C.
Range of in-line carbon block water filters and housings with polypropylene bodies. Maximum working pressure 8.0 bar. Cold water use only.
Fluxo range of Brass & PPSU crimp fittings for use with ‘Fluxo’ PEX/Al/PEX Multilayer Pipe. Crimp joint is achieved by a TH profile crimp jaws. Maximum working pressure 10bar @ 70°C, 6Bar @ 95°C.
Geberit range of ‘FlowFit’ press Fittings for use with ‘Geberit FlowFit Pipe ML’ and ‘Geberit FlowFit Pipe coils ML’ (insulated and uninsulated) PERT/Al/PERT pipes. The fittings are made from PPSU or lead free silicon bronze. Operating parameters: 16.0 bar@cold water and 10.0 bar@70°C.
Range of MULTITUBO tin-plated brass and PPSU press fit fittings for use with MULTITUBO multi layered PE-RT/AL/PE-RT pipe. Maximum working pressure 10.0 bar. Maximum operating temperature 70°C.
Range of press fit fittings with PPSU bodies incorporating stainless steel crimp sleeves and EPDM O-Rings for use with Multitubo multi-layer pipes. Maximum working pressure is 10.0 bar. Maximum operating temperature is 70°C.
Range of copper, bronze or DZR brass capillary solder ring fittings for use with copper pipe (manufactured to EN 1057). Maximum working pressure and operating temperatures: 8-28mm: 25.0 bar @ 30°C, 16.0 bar @ 100°C. 35-54mm: 25.0 bar @ 30°C, 16.0 bar @ 65°C and 10.0 bar @ 100°C.
‘Hansen easy fit’ range of polypropylene compression fittings with EPDM ‘O’-rings for use with metric PE80 (20mm-63mm) and PE100 (32mm-110mm) pipe to AS/NZS:4130 and plastic pipe inserts. For above and below ground use. Maximum working pressure: See models. Maximum operating temperature: Cold water use only.
Range of Redman fittings with mild steel bodies (polyamide coating) for use with Puriton II PE-AL-PE barrier pipe - For above and below ground and cold-water use. Jointing is achieved by hydraulic compression. Maximum working pressures: 12.5 Bar for 63mm SDR 11 PE80 pipe system, 10.0 Bar for 90mm to 180mm SDR 17 PE100 pipe system, 16.0 bar for 90mm to 180mm SDR 11 PE100 pipe system. Cold water use only.
Allpex range of end feed capillary fittings and brazing fittings for use with copper tube (manufactured to BS EN 1057). EG fittings have gunmetal bodies, ED fittings have DZR brass bodies & EB fittings have brass bodies. For above ground use only. Maximum working pressure: 6mm – 34mm 25Bar, 34mm -54mm 25Bar, 54mm – 108mm 16Bar, 108mm – 159mm 5 Bar. Maximum operating temperature 30°C
Range of WC dual flush drop valves with ABS bodies and silicone seals. The valves are operated via a two push button assembly for either full or reduced flush and incorporate an internal overflow. Cold water use only.
Range of WC dual flush drop valves with ABS bodies and silicone seals. The valves are operated via a two push button assembly for either full or reduced flush and incorporate an internal overflow. Cold water use only.
WC dual flush drop valve with ABS body and silicone seals. The valve is operated via a two push button assembly for either full or reduced flush and incorporates an internal overflow. Cold water use only.
WC dual flush drop valve with plastic body silicone and rubber seal. The valve is operated via a push button assembly for either full or reduced flush and incorporates an internal overflow. Cold Water Use Only.
Range of WC dual flush drop valves with plastic bodies and silicone seals. The valves are operated via a two push button assembly for either full or reduced flush and incorporate an internal overflow. Cold water use only.
Range of wall mounted, gas-fired condensing combination boilers providing domestic hot water via a plate heat exchanger and pressurised central heating system incorporating an expansion vessel, pressure relief valve set at 3.0 bar and flow regulators. The inlets to both domestic hot water and primary circuits are controlled via screwdriver operated angled spherical valve. The primary circuit can be filled via a built in CAB device, that has been verified by test (suitable for backflow protection against Fluid Category 3). Primary circuit: Maximum working pressure 2.5 bar. Maximum operating temperature 80°C. Secondary circuit: Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.
‘MJ-SDC plus’ range of water meters with brass bodies, incorporating plastic impellers. The inlets incorporate plastic filters. Maximum working pressure 16 Bar. Maximum operating temperature 50°C.
Range of in-line ultrasonic water meters with DZR brass bodies and a plastic strainer. Maximum working pressure 16.0 bar. Maximum operating temperature 65°C.
Range of water meters with blue epoxy coated ductile iron bodies, plastic measurement chambers and vanes and NBR ‘O’-rings. Maximum working pressure 16.0 bar. Maximum operating temperature 50°C.
Page 11 of 21
We use cookies to give you the best possible experience with WRAS. Some are essential to provide website functions and ensure the website is secure. We also use cookies to help us understand how people use the site and to make improvements. Click "Accept All" to enable recommended settings or click "Manage cookies" to adjust your settings. For more details, see our Cookie Policy.