Single hole, single outlet (swivel) combination tap assemblies (chromium plated brass), incorporating quarter turn ceramic disk headworks with a single lever operating members. The spout outlet incorporates a plastic aerator. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.
Range of single hole, single outlet (swivel) combination tap assemblies with brass bodies (various finishes), incorporating a ceramic cartridge headwork with a single lever operating member. This product also incorporates an additional spring-loaded quarter turn ceramic disc headwork with a single lever operating member for filtered cold water discharged from the spout outlet. The spout outlet incorporates a plastic aerator. Maximum working pressure 5.0 bar. Maximum operating temperature 65°C.
Range of single hole, single outlet (swivel) combination tap assemblies (chromium plated brass), incorporating a quarter turn ceramic disc headwork with a dome type operating member. The temperature is controlled independently via a thermostatic cartridge with a dome type operating member which incorporates a manual override button. The spout outlet incorporates a plastic aerator. The 80CR256TH model is supplied with a pop-up waste. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.
Single hole, double outlet combination tap assembly incorporating (chromium plated) brass body and ceramic disc headwork with single lever operating members. Maximum working pressure 6.0 bar. Maximum operating temperature 85°C. The products are supplied with pop up waste which has not been tested.
Two hole, single outlet (fixed) combination tap assembly (chromium plated brass), incorporating quarter turn ceramic disk headworks with single lever operating members. The spout outlet incorporates a combined EPDM washer with a stainless steel strainer and a plastic flow straightener. The product is supplied with metal backnuts. Maximum working pressure 10.0 bar. Maximum operating temperature 65°C.
Two hole, single outlet (fixed) combination tap assembly (chromium plated brass), incorporating quarter turn ceramic disk headworks with single lever operating members. The spout outlet incorporates a combined EPDM washer with a stainless steel strainer and a plastic flow straightener. The product is supplied with metal backnuts. Maximum working pressure 10.0 bar. Maximum operating temperature 65°C.
Two hole, metal, single outlet (fixed) combination tap assemblies (chromium plated brass) incorporating quarter turn ceramic disc headworks with single lever operating members and a manual diverter to the shower outlet. The spout outlet incorporates a plastic flow straightener. The product is supplied with a shower hose, handset and metal backnuts. Maximum working pressure 10.0 bar. Maximum operating temperature 65°C.
Range of two hole, single outlet (swivel) combination tap assembly with brass bodies (chrome plated), incorporating quarter turn ceramic disc headworks and single lever operating members (model 1607023) or non-rising spindle headworks with dome type operating member (model 167021). The spout outlet incorporates a plastic aerator or plastic flow straightener. The product is supplied with metal backnuts. Maximum working pressure 10.0 bar. Maximum operating temperature 65°C.
Range of wall mounted, two-hole, single outlet (fixed) combination tap assemblies (chromium plated brass) incorporating a lockable self-cancelling diverter to shower outlet. The flow is controlled by a quarter turn ceramic disc headwork with a dome operating member and the temperature is controlled independently via a thermostatic cartridge with a dome operating member and manual override button. Both inlets incorporate stainless-steel strainers and a single check valve cartridge (however, the complete product has not been fully tested to demonstrate it provides backflow protection). The spout outlet incorporates plastic aerator. Maximum working pressure 10 bar. Maximum operating temperature 60°C.
Range of wall mounted, three-hole, single outlet (fixed) combination tap assemblies. The product comprises of a trim set (chromium plated brass) and a concealed brass body. The concealed body incorporates two quarter turn ceramic disc headworks. The trim set includes a brass spout for installation into the concealed body, single lever operating members and a click type pop-up waste. The spout outlet incorporates a plastic aerator. Maximum working pressure 5.0 bar. Maximum working temperature 60°C.
‘Composed’ range of three hole, single outlet (fixed) combination tap assemblies (brass bodies - various finishes, see model), incorporating quarter turn ceramic disc headworks with either single lever or cross top operating members. The spout outlets incorporate a plastic aerator. The products are supplied with stainless steel braided EPDM lined flexible hose assemblies for installation between the side valves and ‘T’ connector, as well as between the ‘T’ connector and the spout. Maximum working pressure 5.0 bar. Maximum operating temperature 65°C.
Four-hole, single outlet (swivel) combination tap assembly (chromium plated brass), incorporating a ceramic cartridge headwork with a single lever operating member and a self-cancelling lockable diverter to shower outlet. The diverter outlet incorporates a single check valve cartridge, verified by test (suitable for backflow protection against Fluid Category 2). The product is supplied with a shower hose and handset. The shower handset inlet incorporates a stainless-steel strainer and a plastic flow regulator with an approved check valve cartridge, however, the complete product has not been fully tested to demonstrate it provides backflow protection The product is also supplied with ⅜" BSP (M) x ½" BSP (F) brass adapters for installation on each inlet hose, as well as stainless steel braided PEX lined flexible hose assemblies and stainless steel braided TPSiV lined flexible hose assemblies used as connecting hoses. The spout outlet incorporates a plastic aerator. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.
Range of floor standing bath mixers (chromium plated brass) incorporating a ceramic cartridge diverter headwork with dome type or single lever (CPHSP30346 model only) operating members. The spout outlet incorporates a plastic flow straightener. The products are supplied with a shower hose and handset and a floor mounting kit. Maximum working pressure 5.0 bar. Maximum working temperature 60°C.
Range of expansion vessels with butyl membranes. Maximum working pressure 8.0, 10.0, 16.0 or 20.0 bar (please refer to model). Maximum operating temperature 70 or 100°C (please refer to model).
Range of expansion vessels with butyl membranes. Maximum working pressure 8.0, 10.0, 16.0 or 20.0 bar (please refer to model). Maximum operating temperature 70 or 100°C (please refer to model).
Range of expansion vessels with butyl membranes. Maximum working pressure 8.0, 10.0, 16.0 or 20.0 bar (please refer to model). Maximum operating temperature 70 or 100°C (please refer to model).
Range of expansion vessels with butyl membranes. Maximum working pressure 8.0, 10.0, 16.0 or 20.0 bar (please refer to model). Maximum operating temperature 70 or 100°C (please refer to model).
In-line carbon block water filter with polypropylene body. Maximum working pressure 6.8 bar. Cold water use only.
Range of brass press-fit fittings incorporating EPDM ‘O’-Rings and stainless steel crimp sleeves for use with Herz multi-layer PE-RT pipes. Maximum working pressure 10 bar. Maximum operating temperature 95°C.
Range of solder ring copper fittings for use with EN1057 copper tube. Maximum working pressure and temperature for 15mm to 54mm 25 bar @ 30°C, 16 bar @ 65°C & 10 bar @ 100°.
CB Range of solder ring brass fittings for use with copper tube (manufactured to EN 1057). Maximum working pressure 16.0 bar. Maximum operating temperature 85°C.
Range of solder ring copper fittings for use with copper tube to EN 1057. The HLSRDPMFWT and HLSRDPMFZT models incorporate a captive nut on one end with a fibre gasket washer. Maximum working pressure 16.0 bar. Maximum operating temperature 85°C.
Range of solder ring brass fittings for use with copper tube (manufactured to EN 1057). Maximum working pressure 16.0 bar. Maximum operating temperature 85°C.
Range of solder ring copper fittings for use with copper tube to EN 1057. The 32565811, 32565814, 32565802, 32565805 & 32565808-S/R models incorporate a captive nut on one end with a fibre gasket washer. Maximum working pressure 16.0 bar. Maximum operating temperature 85°C.
Range of solder ring brass fittings for use with copper tube (manufactured to EN 1057). The HLSR20CB-d tank connector incorporates an EPDM washer. Maximum working pressure 16.0 bar. Maximum operating temperature 85°C.
Range of solder ring copper fittings for use with copper tube to EN 1057. The 304574, 304615 & 304711 and 304756 models incorporate a captive nut on one end with a fibre gasket washer. Maximum working pressure 16.0 bar. Maximum operating temperature 85°C.
Elysee range of polypropolene fittings for use with PE pipe (manufactured to EN 12201). Maximum working pressure 16 bar. Cold water use.
Range of stainless steel (SS316L) pressfit fittings with EPDM ‘O’-rings for use with stainless steel pipe (manufactured to EN10312). Maximum working pressure 16.0 bar. Maximum operating temperature 100°C.
Range of stainless steel (SS316L) pressfit fittings with EPDM ‘O’-rings for use with stainless steel pipe (manufactured to EN10312). Maximum working pressure 16.0 bar. Maximum operating temperature 100°C.
STH Ranges of brass crimp fit fittings incorporating EPDM ‘O’-rings for use with copper pipe (manufactured to EN1057-2006). 74232, 74233, 74234, 74226, 74227, 74228, 74229 & 74231 models also incorporate a NBR gasket. Maximum working pressure 16.0 bar. Maximum operating temperature 85°C.
Range of copper end feed fittings for use with copper tube manufactured to EN1057 For above and below ground use. 5mm to 54mm = Maximum working pressure 25.0 bar. 67mm to 159mm = Maximum working pressure 16.0 bar. Maximum operating temperature 100°C
CB (CENTRE) Range of end feed copper fittings for use with copper tube to EN 1057. Maximum working pressure 16.0 bar. Maximum operating temperature 85°C.
Range of end feed brass fittings for use with copper tube (manufactured to EN 1057). Maximum working pressure 16.0 bar. Maximum operating temperature 85°C.
Range of end feed brass fittings for use with copper tube (manufactured to EN 1057). Maximum working pressure 16.0 bar. Maximum operating temperature 85°C.
Range of end feed copper fittings for use with copper tube to EN 1057. The HLDPMFWT and HLDPMFZT models incorporate a captive nut on one end with a fibre gasket washer. Maximum working pressure 16.0 bar. Maximum operating temperature 85°C.
Range of end feed brass fittings for use with copper tube (manufactured to EN 1057). Maximum working pressure 16.0 bar. Maximum operating temperature 85°C.
Range of end feed copper fittings for use with copper tube to EN 1057. The 30065321,30065313, 30065317,30465313,30065301, 30065305, 30065309, 30465301 & 30465305 models incorporate a captive nut on one end with a fibre gasket washer. Maximum working pressure 16.0 bar. Maximum operating temperature 85°C.
Range of end feed copper fittings for use with copper tube to EN 1057. The 950513 & 950514 & 950501, 950503 & 953102 models incorporate a captive nut on one end with a fibre gasket washer. Maximum working pressure 16.0 bar. Maximum operating temperature 85°C.
Range of electric instantaneous water heaters. The DEX and DCX models incorporate a spherical ball valve on the inlet. The CEX and DEX models incorporate an approved check valve cartridge; however, the complete product has not been fully tested to demonstrate it provides backflow protection. The inlet incorporates a strainer. Maximum working pressure 10 bar (DEX models only) All other models open outlet. Maximum operating temperature: ES3/4/5 and Zip Hydrotap G4/G5 ranges – 65ºC. CEX, DEX and DCX ranges - 70°C.
Range of wall hung, gas fired, combination boilers providing domestic hot water via a plate heat exchanger. The primary circuit incorporates an integral expansion vessel and a pressure relief valve set at 3.0 bar. The product is supplied with a rigid pipe filling loop, followed by a separate isolation valve. The filling loop pipe attaches to the cold water inlet valve which incorporates a double check valve assembly (verified by test, suitable for backflow protection against Fluid Category 3) on the branch to the filling loop. The primary circuit includes an isolation valve on the flow and return and is also supplied with two loose 22mm compression isolation valves and a filter. Maximum working pressure of the primary circuit is 2.5 bar and the maximum supply pressure to the secondary circuit is 10.0 bar. Max operating temperature 65°C.
Range of pressure limiter with stainless steel spring, plastic or chrome plated brass bodies. A5.0022.0 and A5.0027.0 incorporate with a stainless-steel mesh filter. Maximum working pressure 10.0 Bar. Maximum operating temperature 65˚C.
Permanent filling/ pressurisation device for primary heating and chilled water closed circuits in domestic and non-domestic premises. The mains and closed circuit system pressures are continuously checked by two pressure sensors and their differential monitored by microprocessors. In the event of a fall in system pressure, and only if the mains pressure is adequate, a solenoid valve operates to allow water into the system. At all other times a second solenoid valve drains the fill chamber to waste, via tundish (meeting the requirements of an air gap to drain), and allowing air to be admitted via an automatic air vent to create an atmospheric disconnection across the transfer chamber. Maximum working pressure 6.0 Bar. Cold water use only.
Range of vertical multistage booster pumps, with stainless steel bodies and impellors. Maximum working pressure: See models Maximum working temperature 85°C.
Chrome plated interlocked shower hose with EPDM inner liner. Maximum operating temperature 65°C.
Range of shower handsets with a black plastic body and EPDM ‘O’-rings. Model includes a trigger mechanism that alters the spray pattern. Maximum operating temperature 60°C.
Range of shower handsets with chrome plated ABS bodies incorporating NBR o rings. Maximum operating temperature 60°C.
Stainless steel bodied flow switch, with integral plastic plunger. Maximum working pressure 16.0 bar. Maximum operating temperature 80°C.
Range of hose union, spherical valve type bib taps with (nickel plated) brass bodies and chrome plated brass ball. The outlet incporates a plastic flow straightener Maximum working pressure 10.0 bar. Maximum operating temperature 85°C.
Pillar taps (chromium plated brass) incorporating quarter turn ceramic disc headwork with single lever operating members. The spout outlets incorporate a plastic flow straightener. Maximum working pressure 6.0 bar. Maximum operating temperature 85°C.
Pillar tap incorporating (chromium plated) brass body quarter turn ceramic disc headwork with a single lever operating member. The spout outlet incorporates a plastic flow straightener. Maximum working pressure 6.0 bar. Maximum operating temperature 85°C. The product is supplied with metal backnuts.
Page 51 of 236
We use cookies to give you the best possible experience with WRAS. Some are essential to provide website functions and ensure the website is secure. We also use cookies to help us understand how people use the site and to make improvements. Click "Accept All" to enable recommended settings or click "Manage cookies" to adjust your settings. For more details, see our Cookie Policy.