Range of two hole, single outlet (fixed) combination tap assemblies (various finishes, brass bodies), incorporating quarter turn ceramic disc headworks with single lever operating members). The spout outlet either incorporates a plastic flow straightener or an open outlet (see models). The products are supplied with metal backnuts. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.
Range of two hole, single outlet (fixed) combination tap assemblies (various finishes brass bodies), incorporating quarter turn ceramic disc headworks with various operating members (see models). The spout outlet either incorporates a plastic flow straightener or an open outlet (see models). The products are supplied with metal backnuts. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.
Range of two hole, single outlet (fixed) combination tap assemblies with brass bodies (various finishes) incorporating ceramic cartridge headworks with single lever operating members Spout outlets incorporate a plastic aerator. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.
Range of two-hole, single outlet (fixed) combination tap assemblies (chromium plated brass), incorporating quarter turn ceramic disc or ceramic cartridge headworks with either single lever or cross top (L-BS model) operating members and manual diverter to shower outlet. The spout outlet incorporates a plastic flow straightener. The products are supplied with metal back nuts. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.
Two-hole, single outlet (fixed) combination tap assembly (chromium plated brass), incorporating quarter turn ceramic disc or ceramic cartridge headworks with cross top operating members and manual diverter to shower outlet. The spout outlet incorporates a plastic flow straightener. The products are supplied with metal back nuts. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.
Range of two-hole, single outlet (fixed) combination tap assemblies (various finishes, brass bodies), incorporating quarter turn ceramic disc or ceramic cartridge headworks single lever or cross top operating members (see models) and a manual diverter to shower outlet. The spout outlet either incorporates a plastic flow straightener or an open outlet (see models). The products are supplied with metal back nuts. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.
Range of two-hole, single outlet (fixed) combination tap assemblies (chromium plated brass), incorporating quarter turn ceramic disc or ceramic cartridge headworks with single lever or cross top operating members (see models) and a manual diverter to shower outlet. The spout outlet either incorporates a plastic flow straightener or an open outlet (see models). The products are supplied with metal back nuts. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.
Range of PVC lined flexible shower hoses with a black or silver finish. Open outlet use only. Maximum operating temperature 60°C.
Range of Y type strainers with blue epoxy coated ductile iron bodies and EPDM ‘O’-rings. Maximum working pressure 25.0 bar. Maximum operating temperature 85°C
Range of pillar taps (chromium plated brass), incorporating quarter turn ceramic disc headworks with single lever, dome type or cross top operating members and plastic backnuts. The spout outlets incorporate a plastic flow straightener. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.
Range of pillar taps (chromium plated brass), incorporating quarter turn ceramic disc headworks with single lever, dome type or cross top operating members and plastic backnuts. The spout outlets incorporate a plastic flow straightener. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.
Range of pillar taps (chromium plated brass), incorporating quarter turn ceramic disc headworks with single lever, dome type or cross top operating members and plastic backnuts. The spout outlets incorporate a plastic flow straightener. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.
Range of pillar taps (chromium plated brass), incorporating quarter turn ceramic disc headworks with single lever, dome type or cross top operating members and plastic backnuts. The spout outlets incorporate a plastic flow straightener. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.
Range of chromium plated stainless steel or brass interlocked shower hoses with an optional PVC outer layer. Incorporating either a PVC or TPE inner hose and EPDM gaskets. Maximum operating temperature 60°C.
CAIO ranges of Indirect stainless steel insulated hot water storage cylinders with external expansion and copper pipework and fittings. The DHW circuit consists of a temperature and pressure relief valve set at 7.0 bar and 90°C, an inlet control group consisting of a pressure reducing valve adjustable between 2.7 and 3.3 bar, an expansion relief valve (SRV) set at 6.0 bar, a strainer and a check valve cartridge, verified by test (suitable for backflow protection against Fluid Category 2) also supplied with a tundish. Maximum supply pressure to the inlet control group 10.0 bar. Maximum working pressures - Primary circuit 6.0 bar, Secondary circuit 5.5 bar. Maximum operating temperature 65˚C.
Range of compression stop valves incorporating brass bodies, rising spindle headworks and EPDM gaskets. For use with copper pipe manufactured to BS EN 1057 (15mm, 22mm and 28mm) or PE pipe manufactured to BS EN 12201-2 (20mm and 25mm). Maximum working pressure 10.0 bar. Cold water use only.
'ZC-2025HSR'. Factory applied, grey coloured sulphate resistant cement. Mix cement:sand:water in a 1.5:1:0.4 mass ratio and apply as per manufacturer's instructions 'ZC01250725', dated '2025.7.25'. Cure for 8 hours@23°C. For use with water up to 65°C. This material is only approved for the mixing and curing conditions that appear on the approval. If the mixing and/or curing conditions are varied from those specified on the approval then the material is not covered by the scope of the approval.
‘Silicone Grease A665017, 665016-TUB, A665016, ASG50, AHPSG, PH041, PHCB041/F15220’. Off-white coloured (opaque) silicone greases. Apply as per manufacturer's instructions. For use with water up to 65°C.
'F15222 CB Silicone Lubricant' & 'PHCB042 – F15222 Centerbrand Silicone Grease'. Off-white coloured (opaque) silicone greases. Apply as per manufacturer's instructions. For use with water up to 65°C.
'10 EPR 'O' rings'. Black coloured, injection moulded EPDM 'O' rings. Shore hardness 70. Tested in-radius size 1.5mm. For use with water up to 85°C.
'15 EPR, 22 EPR & 28 EPR 'O' rings'. Black coloured, injection moulded 'O' rings. Shore hardness 60. Tested in-radius size 1.8mm. For use with water up to 85°C.
'Aliaxis Solvent Cement'. Clear, transparent (un-pigmented) solvent cement, (intended to join PVC pipe and fittings). Apply as per manufacturer's instructions 'Rev00 08052025'. Cure for 20 days at 7°C. For use with water up to 65°C. This material is only approved for the curing conditions that appear on the approval. If the cure conditions are varied from those specified on the approval then the material is not covered by the scope of the approval.
Side entry BS1212-4 (2016) compact type float operated valve for WC flushing cisterns. The inlet incorporates a flow restrictor. Maximum working pressure 10.0 bar. Cold water use only.
Range of concealed WC flushing cisterns incorporating a side entry compact type float operated inlet valve providing a Type AG air gap with a dual flush drop valve for full flush and reduced flush. The cistern is operated by a manual push button and incorporates a servicing valve and flexible hose on the inlet supply. Maximum working pressure 10.0 bar. Cold water use only. .
Flange fittings with TP2 copper bodies, for use with TP2 copper pipe to EN1057. Above ground use only. Maximum working pressure 16.0 bar. Maximum operating temperature 85°C.
Dual flush, WC outlet valves. The valves are operated via a push button assembly for either full or reduced flush and incorporates an internal overflow. Cold water use only.
Range of chromium plated stainless steel or brass interlocked shower hoses with an optional PVC outer layer. Incorporating either a PVC or TPE inner hose and EPDM gaskets. Maximum operating temperature 60°C.
Range of spring loaded, resilient trim, in-line check valve cartridgse, with plastic guides & jumper and NBR or EPDM seals within a plastic housing. For insertion in pipes and fittings with specifically sized bores. Maximum working pressure 16.0 bar. Models NV20/DN20-EPDM 31.0004.0 & NV20/DN20-pr 31.0071.0 have a maximum operating temperature of 60°C. Models NV20/DN20 31.4221.0 & NV20/DN20-HT 31.0011.0 have a maximum operating temperature of 85°C.
Adaptor, with DZR brass body (chrome plated), which incorporates a single check valve cartridge verified by test (as suitable for backflow protection against Fluid Category 2). Maximum working pressure 16.0 bar. Maximum operating temperature 85°C.
Range of ceramic cartridge headworks with a plastic body and EPDM ‘O’-rings to be inserted into specifically dimensioned bodies. Maximum working pressure 10.0 bar. Maximum operating temperature 85°C.
Range of ceramic disc headworks with brass bodies and EPDM seals. Maximum working pressure 16.0 bar. Maximum operating temperature 85°C.
Range of single hole, single outlet (fixed) combination tap assemblies (chromium plated brass). incorporating a ceramic cartridge and single lever operating member with a spring loaded, pull down trigger operated spray. The spout outlet incorporates a plastic aerator. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.
Range of single hole, single outlet (fixed) combination tap assemblies with brass bodies (various finishes), incorporating ceramic cartridge headworks with single lever operating members. The spout outlets incorporate a plastic aerator. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.
Range of single hole, single outlet (fixed) combination tap assemblies (chromium plated brass), incorporating a ceramic cartridge headwork with single lever or dome type operating members. The spout outlets incorporate a plastic aerator. Maximum working pressure 5.0 Bar. Maximum operating temperature 85°C.
Range of single hole, single outlet (fixed) combination tap assemblies with brass bodies (chrome plated), incorporating a ceramic cartridge headwork with a single lever operating member. The spout outlets of models SAVV2313 & SEV313 incorporate a plastic aerator, model SPA2113/EX incorporates a stainless steel filter. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.
Range of single hole, single outlet (fixed) combination tap assemblies (chromium plated brass) incorporating a ceramic cartridge headwork with single lever operating member. The spout outlets incorporate a plastic aerator and the inlets incorporate a stainless steel strainer. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.
Single hole, single outlet fixed combination tap assembly (chromium plated brass), incorporating a ceramic cartridge headwork with a single lever operating member. The spout outlet incorporates a plastic flow straightener and the product is supplied with a click type waste. Maximum operating pressure 5.0 bar. Maximum operating temperature 60°C
Range of single hole, single outlet (fixed) combination tap assemblies (chromium plated brass), incorporating a ceramic cartridge headwork with a single lever operating member. The spout outlet incorporates a plastic flow straightener with an optional aerator. Fittings are supplied with a pop-up waste. Maximum working pressure 5.0 Bar. Maximum operating temperature 60°C.
Range of single hole, single outlet (fixed) combination tap assemblies (chromium plated brass bodies), incorporating ceramic cartridge headworks with single lever operating members. The spout outlet of models SAV2113/SHD113/SEV113 incorporates plastic aerators. SPA2113 and SPA2313 incorporate a stainless steel mesh at the spout. SAVV2113, SHD113, SEV113, SPA2113, SWO2113 are supplied with a pop-up waste. Maximum working Pressure 10.0 bar. Maximum operating temperature 65ºC.
Range of single hole, single outlet (swivel) combination tap assemblies with brass bodies (various finishes), incorporating ceramic cartridge headworks and single lever operating members. The spout outlet incorporates a plastic aerator. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.
Range of single hole, single outlet (fixed) combination tap assemblies (chromium plated brass), incorporating ceramic cartridge headworks and single lever operating members. The spout outlets incorporate a plastic aerator. Model 1002137653_N199998998 is supplied with a pop up waste. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.
Single hole, single outlet (swivel) comination tap assembly (chromium plated brass). Incorporation a ceramic disc headwork with dome type operating members. The spout outlets incorporate a metal strainer and either a plastic aerator or alternative flow straightener. Maximum working pressure 10.0 bar. Maximum operating temperature 70°C.
Single hole, single outlet (swivel) comination tap assembly (chromium plated brass), incorporation a non-rising spindleheadwork with crosstop type operating members. The spout outlets incorporate a metal strainer and either a plastic aerator or alternative flow straightener. Maximum working pressure 10.0 bar. Maximum operating temperature 70°C.
Range of single hole, single outlet (swivel) combination tap assemblies (chromium plated brass). Incorporating ceramic cartridge headworks and single lever operating members. The spout outlet incorporates a plastic aerator. Maximum working pressure 6.0 bar. Maximum operating temperature 60°C.
Range of single hole, single outlet (swivel) combination tap assemblies with brass bodies (various finishes), incorporating ceramic cartridge headworks and single lever operating members. The spout outlets incorporate a plastic aerator. Maximum working pressure 8.0 bar. Maximum operating temperature 60°C.
Range of single-hole, single outlet, (swivel) combination tap assemblies with brass bodies (various finishes), incorporating quarter turn ceramic cartridge headworks with single lever operating members. The spout outlets incorporate a plastic aerator and the inlets incorporate a stainless-steel strainer. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.
Range of wall mounted, concealed two-hole, single outlet (fixed) combination tap assemblies (brass bodies, various finishes) incorporating ceramic cartridge headwork with single lever operating members. The spout outlets incorporate a plastic aerator, some also incorporate a flow regulator. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C
Range of five hole, single outlet (swivel) combination tap assemblies (chromium plated brass). Incorporating a ceramic cartridge headwork controlling the flow to the shower handset and two quarter turn ceramic disc headworks controlling the flow to the spout outlet, all with single lever operating members. The spout outlets incorporate a plastic aerator. The inlet to the shower handsets incorporate an approved check valve cartridge, however, the complete product has not been fully tested to demonstrate it provides backflow protection. The product is supplied with a shower hose and handset. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.
Range of Aquaterra PP-RCT socket fusion fittings for use with Aquaterra PP-RCT SDR 6 pipe and Aquaterra PP-RCT SDR 7.4 pipe (manufactured to EN ISO 15874). Maximum working pressure 10.0 bar. Maximum working temperature 85°C.
Viega ‘Raxofix’ press connection fittings for use with viega Raxofix PE-Xc/Al/PE-Xc pipes. For above ground use only. Maximum working pressure 10 bar. Maximum operating temperature 70°C
Page 45 of 71
We use cookies to give you the best possible experience with WRAS. Some are essential to provide website functions and ensure the website is secure. We also use cookies to help us understand how people use the site and to make improvements. Click "Accept All" to enable recommended settings or click "Manage cookies" to adjust your settings. For more details, see our Cookie Policy.