Range of single hole, double outlet (fixed) combination tap assemblies (various finishes) with electronically controlled functions to allow the tap to dispense boiling water, chilled water or sparkling water from under counter units (not supplied). The spout outlet of ‘Arc’ models incorporates a plastic flow straightener. All models incorporate a separate vent outlet within the tap spout for the near-boiling water circuit. Near-boiling circuit has a maximum operating temperature 100°C. Hot-water circuit has a maximum operating temperature of 65°C.
Range of boiling water dispensers incorporating plastic (3-7.5 litre models) or stainless steel (10-40 litre models) cisterns with silicone ‘O’-rings and seals. The flow to the internal reservoir is controlled via a float valve. The internal reservoir incorporates an overflow which acts a vent. The inlet incorporates a plastic filter. Water is dispensed using either a lever or push button (PLUS models only) operated self-closing tap. Maximum working pressure 5.0 bar. Maximum operating temperature 98°C. Cold supply only.
‘G5 BC’ range of command centres that provide instant near boiling and chilled water (both filtered) via an electronically controlled tap (not supplied). Flow is controlled via a combination of solenoid valves and electronic pumps to the outlets. The products are supplied with a filter cartridge. The products can also be supplied with a hot water booster and/or a venturi system to provide mains cold water combined with water from the hot water tank (see model). Maximum working pressure 5.0 bar. Maximum operating temperature 100˚C. Cold supply only.
‘G5 BCS’ range of command centres that provide instant near boiling, sparkling and chilled water (all filtered) via an electronically controlled tap (not supplied). Flow is controlled via a combination of solenoid valves and electronic pumps to the outlets. The products incorporate a pressure reducing valve (adjustable outlet pressure between 2.25 and 2.75 bar) on the supply to the carbonator unit. The carbonator inlet incorporates a non-return valve. The products are supplied with a filter cartridge. The products can also be supplied with a hot water booster and/or a venturi system to provide mains cold water combined with water from the hot water tank (see model). Maximum inlet supply pressure 5.0 bar. Maximum operating temperature 100˚C. Cold supply only.
‘G5 BCU60 UV’ Command centre that provides instant near boiling and chilled water (both filtered) via an electronically controlled tap (not supplied). Flow is controlled via a combinations of solenoid valves and electronic pumps to the outlets. A UV unit is incorporated on the outlet from the chilled water tank. The products are supplied with a filter cartridge. The products can also be supplied with a hot water booster and/or a venturi system to provide mains cold water combined with water from the hot water tank (see model). Maximum working pressure 5.0 bar. Maximum operating temperature 100˚C. Cold supply only.
Single hole, triple outlet (swivel) combination tap assembly (brass bodies, various finishes - see model), incorporating a ceramic cartridge headwork with single lever operating member. Electronic controls allow the tap to dispense boiling, chilled or sparkling water. The vented models are supplied with a brass adaptor containing a plastic flow regulator and a combined EPDM washer and stainless-steel strainer, for installation on the mains cold water into the ceramic cartridge. They are also supplied with a stainless steel braided PEX lined flexible hose assembly and a stainless steel braided TPSiV lined flexible hose assembly both with ½” captive nut end connections for installation between the tap and a command centre, (which is not included as part of this approval). Maximum working pressure 5.0 bar. Maximum operating temperatures: Near boiling water circuit: 100°C. Ambient hot and cold (mixed) circuit: 65°C. Chilled/Chilled and sparkling circuit: Cold water use only.
‘G5 B’ & ‘G5 BA’ ranges of command centres that provide instant near boiling (filtered) via an electronically controlled tap (not supplied). Flow is controlled via a combination of solenoid valves and electronic pumps to the outlets. The products are supplied with a filter cartridge. The products can also be supplied with a venturi system to provide mains cold water combined with water from the hot water tank (see model). Maximum working pressure 5.0 bar. Maximum operating temperature 100˚C. Cold supply only.
Range of single hole, single outlet, swivel combination tap assemblies (brass bodies, various finishes - see model), incorporating a ceramic cartridge headwork with a single lever operating member. The vented models are supplied with a stainless steel braided PEX lined flexible hose assembly incorporating a ½" captive nut end connection, which provides main cold water to a venturi device which is part of a command centre (not supplied). The Arc vented models are supplied with a DZR brass tee piece, two DZR brass adaptors, two stainless-steel strainers (each combined with an EPDM washer) and a plastic flow restrictor, for installation prior to the cold inlet hose. The Arc and Cube mains models are supplied with two DZR brass adaptors and two stainless-steel strainers (each combined with an EPDM washer), for installation on each inlet hose. The spout outlet incorporates a plastic aerator. Maximum working pressure 5.0 bar.
Non-metallic materials and components comply with BS6920 at 65°C
Range of single hole, single outlet (fixed) combination tap assemblies (various finishes - see model). Electronic controls on the left-hand side of the body allow the tap to dispense one or more of the following (model specification dependent): ambient, near boiling, chilled or sparkling water. The spout incorporates a plastic aerator on the Sparkling/Ambient/Chilled outlet, and a separate outlet for the near boiling water. All models incorporate a vent outlet within the tap spout for the near-boiling water circuit. Near-boiling circuit has a maximum operating temperature of 98°C. All other circuits have a maximum operating temperature of 65°C.
‘G5 C’ command centre providing chilled (filtered) water via an electronically controlled tap (not supplied). Flow is controlled via a combination of solenoid valves and electronic pumps to the outlets. The products are supplied with a filter cartridge. The inlet to the command centre incorporates two approved check valve cartridges, however, the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum inlet supply pressure 5.0 bar. Cold water use only.
Page 1 of 2
We use cookies to give you the best possible experience with WRAS. Some are essential to provide website functions and ensure the website is secure. We also use cookies to help us understand how people use the site and to make improvements. Click "Accept All" to enable recommended settings or click "Manage cookies" to adjust your settings. For more details, see our Cookie Policy.