Range of single hole, single outlet, electronically controlled tap assemblies (brass body – various finishes). The flow is controlled via a solenoid valve and activated by an infra-red sensor on the front of the spout. The spout outlet incorporates a plastic aerator. Models xxx.yyy.170E/W are supplied with a click clack waste. Maximum working pressure 5.0 bar.
Non-metallic materials and components comply with BS6920 at 60°C
Range of single hole, single outlet (fixed) electronically controlled combination tap assembles with brass bodies (various finishes). Flow is controlled via a solenoid valve activated via an infra -red sensor. The temperature is controlled via a ceramic cartridge and a single lever operating member. The inlet adaptor incorporates a single check valve cartridge (verified by test, suitable for backflow protection against fluid category 2). The outlet incorporates a stainless-steel strainer and an aerator. Maximum working pressure 5.0 bar Maximum operating temperature 60°C.
Range of single hole, single outlet (fixed) electronically controlled tap assemblies (chromium plated brass). Flow is controlled by a solenoid valve activated by via an infra-red sensor and a manual lever to control the outlet temperature. The spout outlet incorporates a plastic aerator. Maximum working pressure 5.0 Bar. Temperature:60°C.
Non-metallic materials and components comply with BS6920 at 60°C
Range of wall mounted, single-hole, single outlet (fixed) electronically controlled combination tap assemblies (chrome plated brass bodies). Flow is controlled via a solenoid, activated via an infra-red sensor. The outlets incorporate plastic aerators. Maximum working pressure 8.0 bar Maximum operating temperature 70°C
Non-metallic materials and components comply with BS6920 at 70°C
Range of wall mounted, electronically operated, combination tap assemblies (stainless steel body, various finishes - see model), comprising of a Premix control unit and a spout. The flow is controlled by a solenoid valve, (Premix control unit), which is actuated via an infrared sensor. The central section of the valve incorporates a plastic strainer. Both inlets of the Premix control unit incorporate an approved single check valve cartridge, however the complete assembly has not been tested for backflow protection. The spout outlet incorporates a plastic aerator. Maximum working pressure 8.0 bar. Maximum operating temperature 60°C.
Non-metallic materials and components comply with BS6920 at 60°C
Concealed WC dual flushing cistern with a bottom entry BS 1212 - 4(2016) float operated inlet valve providing a Type AG air gap arrangement and a dual flush outlet valve. The flush volume is operated by a two-push button assembly for a 6 or 3 litre flush volume. Maximum working pressure 10.0 bar, cold water use only.
Undercounter boiling water cistern with a stainless steel body, stainless steel element and silicone ‘O’-rings and gaskets. Maximum working pressure 8.0 bar. Maximum operating temperature 95°C.
Quarter turn ceramic disc headwork with brass body, NBR and silicone rubber ‘O’ rings, for insertion into specifically dimensioned tap assemblies. Maximum working pressure 10.0 bar. Maximum operating temperature 90°C
Non-metallic materials and components comply with BS6920 at 90°C
Quarter turn ceramic disc headwork with brass body, NBR and silicone rubber ‘O’ rings, for insertion into specifically dimensioned tap assemblies. Maximum working pressure 10.0 bar. Maximum operating temperature 90°C
Non-metallic materials and components comply with BS6920 at 90°C
Range of ceramic cartridges or 2-way ceramic disc diverter headworks with plastic bodies, EPDM ‘O’-rings and/or gaskets, for insertion into specifically dimensioned bores. The JA01AJ and AH01AJ models incorporate a thermostatic element. Maximum working pressure 5.0 bar.
Non-metallic materials and components comply with BS6920 at 85°C
Range of single hole, single outlet (swivel) combination tap assemblies (various finishes) incorporating ceramic cartridge headworks with single lever operating member. The outlet is a pull-out spray type and incorporates a plastic aerator. The inlet hoses incorporate stainless steel strainers. Models 5059340452869 have a maximum working pressure of 10.0 bar. All other models have a maximum working pressure of 5.0 bar.
Non-metallic materials and components comply with BS6920 at 60°C
Range of floor mounted, single hole, single outlet fixed combination tap assemblies, (brass bodies - various finishes), incorporating a ceramic cartridge headwork with a single lever operating member and a self- cancelling diverter to shower outlet. This spout outlet incorporates a plastic aerator. The product is supplied with a shower hose and handset. Maximum working pressure 10.0 Bar.
Non-metallic materials and components comply with BS6920 at 60°C
Single hole, single outlet (swivel) combination tap assembly, (chrome plated brass body) incorporating ceramic cartridge headwork with a single lever operating member. The spout outlet incorporates a plastic aerator. Maximum working pressure 4 bar.
Non-metallic materials and components comply with BS6920 at 65°C
Single hole, single outlet (swivel) combination tap assemblies (chromium plated brass) incorporating a ceramic headwork with single lever operating members. The products incorporate a connection for filtered water supply controlled by quarter turn ceramic disc headwork. The spout outlets incorporate plastic aerator. A separate supply for Maximum working pressure 5.0 bar.
Non-metallic materials and components comply with BS6920 at 60°C
Single hole, single outlet (swivel) combination tap assembly (brass bodies - chrome finish), incorporating a ceramic cartridge headworks with a single lever operating member. The spout outlet incorporates a plastic aerator. Maximum working pressure 5.0 Bar Maximum operating temperature 60.0°C
Non-metallic materials and components comply with BS6920 at 60°C
Range of single hole, single outlet (swivel) combination tap assemblies, (brass bodies – various finishes) incorporating quarter turn ceramic disc or ceramic cartridge headworks with single lever operating members. The spout outlets incorporate a plastic aerator. Maximum working pressure 5.0 BAR
Non-metallic materials and components comply with BS6920 at 60°C
Range of wall mounted two hole, single outlet, combination tap assemblies with brass bodies, incorporating a ceramic cartridge headwork and single lever operating member. This product incorporates a plastic aerator. Maximum working pressure 10.0 bar.
Non-metallic materials and components comply with BS6920 at 60°C
Deck mounted, two hole, single outlet (fixed) combination tap assembly (chromium plated brass), incorporating quarter turn ceramic disc headworks with single lever operating members and a self-cancelling diverter to shower outlet. The spout incorporates a waterfall outlet. Each inlet incorporates a plastic flow regulator. The product is supplied with a shower hose and handset, and metal backnuts. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.
Non-metallic materials and components comply with BS6920 at 60°C
Two-hole, single outlet, (fixed) combination tap assemblies, (brass bodies – various finishes) incorporating a quarter turn ceramic disc headwork and a thermostatic cartridge with cubed type operating members incorporating a manual override button. The spout outlet incorporates a plastic aerator. The inlets incorporate approved check valve cartridge(s); however, the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum working pressure 5.0 Bar
Non-metallic materials and components comply with BS6920 at 60°C
Deck mounted, two-hole, single outlet (fixed) combination tap assemblies, (chrome plated brass bodies) incorporating quarter turn ceramic disc headworks with single lever operating members and lockable diverter to shower outlet. The spout outlet incorporates a plastic aerator. Product is supplied with shower hose, shower handset and metal backnut. Maximum working pressure 10.0 bar.
Non-metallic materials and components comply with BS6920 at 60°C
Range of three-hole, single outlet (fixed) combination tap assemblies (brass bodies – various finishes). Incorporating quarter turn ceramic disc headworks with single lever, cross top, or dome type operating members. The spout outlets for models (F4184, F6182B & F9484) incorporate a plastic aerator and models (F6182C & F8118) are open outlet. The products are supplied with stainless-steel braided EPDM lined flexible hoses to headworks to the spout outlet. Maximum working pressure 5.0 Bar
Non-metallic materials and components comply with BS6920 at 65°C
Range of three-hole, single outlet (fixed) combination tap assemblies (brass bodies - various finishes), incorporating quarter turn ceramic disc headworks with single lever or cross top operating members. The spout outlet incorporates a plastic aerator, and the products are supplied with a lever type pop-up waste. The products are also supplied with either stainless steel or nylon braided PEX lined flexible hoses for connection between the headworks and the spout outlet. Maximum working pressure 10.0 Bar.
Non-metallic materials and components comply with BS6920 at 70°C
Range of three-hole, metal, single outlet (fixed), wall mounted combination tap assemblies (brass body, black finish) incorporating quarter turn ceramic disc headworks and single lever operating members. The spout outlet incorporates a plastic aerator. Maximum working pressure 10.0 Bar.
Non-metallic materials and components comply with BS6920 at 60°C
Wall mounted spout outlet with chromium plated brass body incorporating a plastic flow regulator on the inlet and a plastic strainer at the outlet. Open outlet use only.
Non-metallic materials and components comply with BS6920 at 60°C
Range of wall mounted spouts (chrome plated brass) with a plastic aerator at the outlet. Open outlet use only.
Non-metallic materials and components comply with BS6920 at 60°C
Five-hole, single outlet (fixed) combination tap assembly (brass body - various finishes), incorporating quarter turn ceramic disc headworks with cube type operating members and a manually operated diverter to the shower outlet. The product is supplied with stainless-steel braided EPDM lined flexible connection hoses to connect the headworks, spout and diverter. Maximum working pressure 5.0 Bar.
Non-metallic materials and components comply with BS6920 at 60°C
Deck mounted, swivel spout outlet with a chromium plated brass body, incorporating a plastic aerator at the outlet. Open outlet use only.
Non-metallic materials and components comply with BS6920 at 60°C
Range of horizontal or vertical expansion vessels with an EPDM membrane. Maximum working pressure 10.0 or 16.0 bar (please refer to model). Maximum operating temperature 100°C.
Range of in-line water filters with polypropylene bodies. Maximum working pressure 8.5 bar. Cold water use only.
Non-metallic materials and components comply with BS6920 at cold water use only°C
Range of in-line water filters with polypropylene bodies. Maximum working pressure 8.5 bar. Cold water use only.
Non-metallic materials and components comply with BS6920 at cold water use only°C
Range of in-line water filters with polypropylene bodies. Maximum working pressure 8.5 bar. Cold water use only.
Non-metallic materials and components comply with BS6920 at cold water use only°C
Range of water filter cartridges (plastic bodies with a metal sleeve). Maximum working pressure 8.6 bar. Cold water use only.
Range of copper press fittings with EPDM seals for use with EN1057 copper tube. The joints are achieved by means of a press tool. Maximum working pressure 16.0 bar. Maximum operating temperature 99°C.
“Inox press-fitting system” range of stainless-steel press fittings with EPDM ‘O’-rings for use with stainless steel pipe (manufactured to EN10312 series 2). Joints are achieved using a press fitting tool. Maximum working pressure 16.0 bar.
Non-metallic materials and components comply with BS6920 at 95°C
Range of Easytec press fittings for use with Easytec multilayer (Pe-rt/Al/Pe-rt) pipe. Hewing range of ‘Easytec’ Multilyer Composite Pipe and Press Fitting system with brass press fittings with stainless steel sleeves incorporating EPDM o-rings. 16mm to 32 mm are LBP fittings and from 40mm to 63 mm are standard fittings. Joints are achieved via TH profile press tool. Maximum working pressure: 10bar Maximum working temperature: 95°c
Range of Gerpex press fittings for use with Alpert multilayer (Pe-rt/Al/Pe-rt) pipe. Alpert Multilyer Composite Pipe and Press Fitting system with brass press fittings with stainless steel sleeves incorporating EPDM o-rings. 16mm to 32 mm are LBP fittings and from 40mm to 63 mm are standard fittings. Joints are achieved via TH profile press tool. Maximum working pressure: 10bar Maximum working temperature: 95°c
Range of 'PF Press' TH Profile Brass Press Fittings for use with 'PF Press' Pert-al-Pert Multilayer pipe manufactured to EN ISO 21003 in sizes 16mm, 20mm, 26mm and 32mm. Maximum working pressure 10 bar. Maximum operating temperature: 16mm & 32mm - 95°C. 20mm & 26mm - 23°C between May 2023 to November 2023 and 95°C December 2023 onwards.
Range of brass bodied compression fittings for use with copper pipe(manufactured to EN1057). . Maximum working pressure 16.0 bar @ 30°C, 10.0 bar @ 65°C and 6.0 bar @ 100°C.
Range of compression fittings with brass bodies for use with copper pipe (EN1057). Above ground use only. Maximum working pressure 16 bar. Maximum operating temperature 85°C.
Range of “Effast” ABS fittings for use with ABS pipe complying with BS EN 5391-2006. Maximum working pressure: 15 Bar. Maximum operating temperature: 23°C.
Range of end feed copper solder fittings for use with copper tube. Maximum working pressure 16.0 bar. Maximum operating temperature 99°C.
Range of float operated electrical switches with plastic bodies. Cold water use only.
Range of stainless-steel plate heat exchangers. Maximum working pressure 10 bar. Maximum operating temperature 90°C.
‘G5 BC’ range of command centres that provide instant near boiling and chilled water (both filtered) via an electronically controlled tap (not supplied). Flow is controlled via a combination of solenoid valves and electronic pumps to the outlets. The products are supplied with a filter cartridge. The products can also be supplied with a hot water booster and/or a venturi system to provide mains cold water combined with water from the hot water tank (see model). Maximum working pressure 5.0 bar. Maximum operating temperature 100˚C. Cold supply only.
‘G5 BCS’ range of command centres that provide instant near boiling, sparkling and chilled water (all filtered) via an electronically controlled tap (not supplied). Flow is controlled via a combination of solenoid valves and electronic pumps to the outlets. The products incorporate a pressure reducing valve (adjustable outlet pressure between 2.25 and 2.75 bar) on the supply to the carbonator unit. The carbonator inlet incorporates a non-return valve. The products are supplied with a filter cartridge. The products can also be supplied with a hot water booster and/or a venturi system to provide mains cold water combined with water from the hot water tank (see model). Maximum inlet supply pressure 5.0 bar. Maximum operating temperature 100˚C. Cold supply only.
Range of wall mounted combination boilers providing domestic hot water via a plate heat exchanger and pressurised central heating system. The primary circuit incorporates a pressure relief valve set at 3.0 bar and an expansion vessel. The products are supplied with a temporary filling loop which incorporates a combined isolation valve and double check valve assembly (suitable for backflow protection against Fluid Category 3), stainless steel braided EPDM lined flexible hose assembly and an isolation valve. The secondary circuit (DHW) incorporates a stainless-steel strainer. The primary circuit incorporates isolation valves on the flow and return. Maximum working pressures: DHW: 10.0 Bar CH:2.5 Bar Maximum operating Temperatures: DHW: 65.0°C CH: 85.0°C
‘DM900’ range of flow measuring devices with stainless steel bodies. Maximum working pressure 25.0 bar. Maximum operating temperature 99°C.
Hattersley M2000 range of flow measuring devices with stainless steel bodies. Maximum working pressure 25.0 bar. Maximum operating temperature 99°C.
Range of pressure, flow and temperature sensors. The VFI sensors have stainless steel bodies, all other models have plastic bodied sensors. The MFS and VFS models are supplied with a plastic (composite) or stainless-steel flow pipe. The VFI models are supplied with a stainless-steel flow pipe. The products can also be supplied with a range of fittings/end connections (see model and size). Maximum working pressures: ITS, LPS, RPS, MFS (composite flow pipe) and VFS (composite flow pipe) models: 24.0 bar. CPS models (added February 2024): 24.0 bar. DPS: Models with vent hole: 16.0 bar. All other models: 24.0 bar. MFS (stainless steel flow pipe) and MFS (stainless steel flow pipe): 30.0 bar. VFI non-flanged models: 30.0 bar. VFI flanged models: 30.0 bar or as per flange PN rating 16.0 bar or 25.0 bar (whichever is lower). Maximum operating temperature 99°C.
Permanent filling devices for primary heating and chilled water closed circuits in domestic and non-domestic premises. The mains and closed circuit system pressures are continuously checked by two pressure sensors and their differential monitored by microprocessors. If the mains pressure is adequate and there is a drop in system pressure, then the two solenoid valves operate to allow water into the system via the transfer chamber. At all other times the normally open solenoid valve drains the transfer chamber to waste, via tundish (meeting the requirements of an air gap to drain), and allowing air to be admitted via an automatic air vent to create an atmospheric disconnection across the transfer chamber. Stainless steel strainer on the inlet supply. Mikrofill 3: Maximum working pressure 5.0 Bar. Cold water use only. Mikrofill 3 Pro (72846): Maximum working pressure 9.0 Bar. Cold water use only.
Page 42 of 82
We use cookies to give you the best possible experience with WRAS. Some are essential to provide website functions and ensure the website is secure. We also use cookies to help us understand how people use the site and to make improvements. Click "Accept All" to enable recommended settings or click "Manage cookies" to adjust your settings. For more details, see our Cookie Policy.