Single hole, single outlet (swivel) combination tap assemblies (brass bodies - various finishes), incorporating a ceramic cartridge headwork with a single lever operating member. The spout outlet incorporates a plastic aerator. Maximum working pressure 10.0 Bar Maximum operating temperature 65.0°C
Range of single hole, single outlet (swivel) combination tap assemblies, (brass bodies – various finishes). Model 187007 X XXX incorporates ceramic disc headworks with cross top operating members. Model 187006 X XX incorporates a ceramic cartridge headwork with a lever type operating member. The spout outlets incorporate a plastic aerator or flow straightener. Maximum working pressure 10 bar. Maximum operating temperature 85°C.
Range of wall mounted two-hole, single outlet (fixed) combination tap assemblies (brass bodies - various finishes). Incorporating a ceramic cartridge headwork with dome type operating members. The spout outlet incorporates a plastic aerator. Maximum working pressure; 10 Bar Maximum operating temperature 65°C
Wall mounted two-hole, single outlet (fixed) combination tap assemblies with brass bodies (chromium plated), incorporating a ceramic cartridge headworks and single lever operating member. The spout outlet incorporates a plastic aerator. Maximum working pressure: 5 bar. Maximum operating temperature: 60°C
Range of two hole, deck mounted, single outlet fixed combination tap assemblies incorporating quarter turn ceramic disc headworks with single lever operating members. Models XB-SL-046 and 079 incorporate plastic aerators, models XB-SL-049, 051 and 053 incorporate plastic flow straighteners. The products are supplied with metal back nuts. Maximum working pressure 10.0 bar. Maximum operating temperature for XB-SL-038 85oC, all other models are 65⁰C.
Range of wall mounted, two-hole, single outlet (fixed) combination tap assemblies, (brass bodies - various finishes), incorporating a ceramic cartridge headwork with single lever operating members and a manual diverter to shower outlet. The spout outlet incorporates a plastic aerator. Both inlets incorporate stainless steel strainers and approved check valve cartridges however, the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum working pressure 10.0 Bar Maximum operating temperature 60.0°C
Range of two hole, single outlet (fixed) combination tap assemblies (brass bodies – various finishes), incorporating a quarter turn ceramic disc headwork with a dome type operating member and a self-cancelling diverter to shower. The temperature is controlled independently via a thermostatic cartridge incorporating a dome type operating member and a manual override button. Each inlet incorporates a stainless-steel strainer, and an approved check valve cartridge, however, the complete product has not been fully tested to demonstrate it provides backflow protection. The spout outlet incorporates a plastic flow straightener. Supplied with hose and handset. Maximum working pressure 10.0 bar. Maximum operating temperature 65°C
Range of two hole, single outlet (swivel) combination tap assemblies (brass bodies – various finishes), incorporating quarter turn ceramic disc headworks with either single lever, dome type or wheel operating members. The spout outlet incorporates a plastic aerator and the products are supplied with metal backnuts. Maximum working pressure; 10 Bar Maximum operating temperature 60°C
Range of two-hole, single outlet (swivel) combination tap assemblies (chromium plated brass). Incorporating quarter turn ceramic disc headworks and single lever operating members. The spout outlet incorporates a plastic aerator. The products are also supplied with metal backnuts. Maximum working pressure 8.62 Bar Maximum operating temperature 60.0°C
Range of wall mounted, two-hole, single outlet (swivel) combination tap assemblies (chromium plated brass) incorporating quarter turn ceramic disc headwork with single lever operating members. The spout outlets incorporate a plastic aerator, and the products are supplied with metal backnuts. Maximum working pressure 8.62 Bar Maximum operating temperature 60.0°C
Range of spout outlets (brass bodies – various finishes) incorporating a plastic aerator. The product is also supplied with metal backnuts. Maximum working pressure 5.0 Bar Maximum operating temperature 60.0°C
Range of wall mounted spout outlets (brass bodies - various finishes) incorporating a plastic aerator at the outlet. Open outlet use only. Maximum operating temperature 60°C.
Range of free standing sanitary macerating disposal units. The flow is controlled by solenoid valve and discharges via type a type `AB` airgap (verified by test - suitable for backflow protection against fluid category 5). Maximum working pressure 10.0 bar. Cold water use only.
Bed pan macerator with flow controlled by solenoid valve and discharged via a type `AB` airgap (verified by test - suitable for backflow protection against fluid category 5). Maximum working pressure 8.0 bar. Cold water use only.
Filling loop assembly, incorporating a stainless-steel braided EPDM lined flexible hose assembly, an isolation valve (DZR brass body) and a combined isolation valve and non-verifiable double check valve assembly (DZR brass body) which incorporates 2 check valve cartridges, verified by test (suitable for backflow protection against Fluid Category 3). Maximum working pressure 10.0 bar. Maximum operating temperature 85°C.
Filter cartridge with a plastic body. Maximum working pressure 8.0 bar. Cold water use only.
Range of copper press fittings (‘M’ type crimp profile) and brass threaded adaptor fittings, for use with copper pipe (EN1057). Maximum operating pressure - 16 bar @ 30°C and 10 bar @ 95°C.
Range of plastic compression fittings incorporating polypropylene bodies& plastic pipe liners.. For use with both PE80 & PE100 pipe manufactured to BS EN 12201. Maximum working pressure 16 Bar Maximum operating temperature 23°C
Range of ‘B’ Press XL copper crimped fittings with EPDM ‘O’-rings for use with copper pipe to BS EN1057. Maximum working pressure 16.0 bar. Maximum operating temperature 85°C.
Range of copper crimped fittings with EPDM ‘O’-rings for use with copper pipe manufactured to EN1057. For above and below ground use. Maximum working pressure 16 Bar. Maximum operating temperature 99°C.
B Profile range of 316L & 304 stainless steel press fittings with EPDM ‘O’-rings for use with stainless steel pipe manufactured to EN 10312, for both above and underground use. Joints are achieved by the use of a press fitting tool. Maximum working pressure 16.0 Bar. Maximum operating temperature 85°C.
Range of R-154 stainless steel pressed collars incorporating stainless steel bodies (304L or 316L) and are only to be used with stainless steel pipe. Maximum working pressure for sizes up to DN150 (FCM models) or DN125 (FCI models) is 25.0 bar. Maximum working pressure for size DN200 (FCM models) or DN150 and DN200 (FCI models) is 16.0 bar. Maximum operating temperature 99°C.
Range of wall mounted, electronic tap assemblies which are set within a mirrored cabinet unit. The flow is controlled by a solenoid valve assembly and is activated via infra-red non touch operation. The units also incorporate a soap dispenser and hand dryer or paper towel dispenser. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C
‘PREMIX’ range of wall hung, gas-fired condensing combination boilers providing domestic hot water via a plate heat exchanger. The pressurised central heating system incorporates an expansion vessel and pressure relief valve set at 3.0 bar. The supplies to both the domestic hot water and primary circuit are controlled via spherical valves. Maximum working pressures: Primary circuit: 2.5 bar, Secondary circuit 10.0 bar. Maximum operating temperature both circuits: 80°C.
Range of in-line water meters with plastic bodies. The inlet incorporates a plastic filter. Maximum working pressure; 16 Bar Maximum operating temperature 50°C
Range of ultrasonic remote transmission water meters with stainless steel body. The products incorporate a single check valve cartridge, verified by test (suitable for backflow protection against Fluid Category 2). Maximum working pressure 16.0 bar. Maximum operating temperature 50°C.
Range of VEGAPULS radar sensors for level measurement with plastic bodies. Cold water use only. Open outlet use only.
Range of ‘Thermowatt’ immersion heater elements incorporating brass or DZR heads with either a copper, stainless steel, alloy or titanium heating element and a black EPDM ‘O’-ring. Open outlet use only. Maximum operating temperature 99°C
`Prox’ and ‘Wave` ranges of sensor operated flow control devices incorporating a normally closed solenoid valve to control the flow and operated via an infra-red sensor. The inlet incorporates a stainless-steel strainer. Maximum working pressure 8 Bar Maximum operating temperature 65°C
Range of leak detection devices incorporating a DZR brass body and non-return valve (not intended for and not suitable for backflow protection). Models Stopleak 1 & Stopleak 2 incorporate a spherical valve. Maximum working pressure 10.0 bar. Maximum operating temperature 65°C.
Range of wall brackets (brass bodies – various finishes). Open outlet use only Maximum working temperature 85°C
Range of positive displacement diaphragm pumps with plastic bodies, EPDM ‘O’-rings and TPE diaphragm. The product incorporates an integral bypass relief valve. For use with John Guest LLDPE Pipe. Maximum working pressure 12.0 Bar. Maximum operating temperature 40.0°C.
Range of single stage booster pumps incorporating a flow switch. Model 46349 CH 12-14 B is supplied with a pressure vessel and incorporates an approved check valve cartridge; however, the complete product has not been fully tested to demonstrate it provides backflow protection. Supplied with a strainer and stainless-steel braided EPDM lined flexible connection hoses. Maximum working pressure 6.0 bar. Maximum operating temperature 65°C.
Range of wall or ceiling mounted shower outlets (chromium plated brass). All models except SH5010 incorporate a flow regulator. Open outlet use only. Maximum operating temperature 65 °C.
Range of showerheads with a plastic body (various finishes - see model) and brass connections. The A7889, A7890 and A7891 models incorporate two solenoids controlling the flow to the spray plate or a central plastic aerator. The showerhead inlet also incorporates a plastic flow regulator (except for the A7889 models). Open outlet use only. Maximum operating temperature 60.0°C
EASO range of shower head and hand showers, with ABS bodies and chromium plated finish. Open outlet use. Maximum operating temperature - 65 °C.
Shower handset with plastic body. Maximum operating temperature 85C Open outlet use only
Non-metallic materials and components comply with BS6920 at 70°C
Chrome plated brass shower handset. Maximum working pressure 10.0 bar. Maximum operating temperature 85°C.
Shower outlet kit, consisting of chromium plated ABS shower handset and PVC lined shower hose. The kit is also supplied with a riser rail and handset retainer. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.
Range of adjustable ceiling and wall mounted shower arms available with brass bodies (various finishes). Maximum operating temperature 85°C.
Wall mounted shower set comprising of an inlet connection, shower handset (brass bodies, various finishes), shower holder and EPDM lined shower hose. Maximum operating temperature 85⁰C.
Range of overhead shower outlets with brass bodies (various finishes). The products incorporate a plastic flow regulator. Models listed are to be used in conjunction with the 26 471 180 basic set. Maximum operating temperature 65°C.
Range of shower outlets comprising of shower heads all incorporating stainless-steel strainer washers (plastic bodies-various finishes) and handheld showers (plastic bodies - various finishes). Maximum operating temperature 75°C.
Range of overhead shower and shower handsets with (brass or plastic bodies – various finishes), incorporating a stainless-steel strainer on the inlets. Open outlet use only Maximum operating temperature – 85°C.
Range of shower arms, (stainless steel bodies – various finishes). Open outlet use only. Maximum operating temperature - 85°C
Range of Y pattern strainers having either brass (899ST range) or bronze (900 range) bodies and PTFE seat washers. Maximum working pressure 20.0 Bar (Model 900), Maximum working pressure 32.0 Bar (Model 899ST). Maximum operating temperature 100.0°C.
Flow sensor with a plastic and brass body. Maximum working pressure 16.0 bar. Maximum operating temperature 80°C.
Range of drain valves with a brass bodies, spindle and EPDM ‘O’-rings. Maximum working pressure 16.0 bar. Maximum operating temperature 99°C.
Range of wall mounted hose union bib taps incorporating a rising spindle headwork with a T - handle operating member. Model 13.20202.G15.CP5R-8511 has a DZR brass body, all other models have a brass body. Model 13.20252.G15.CP5R-8510 incorporates a lockshield device at the base of the operating stem. The spout outlets incorporate a hose union connector. Maximum working pressure 16.0 bar. Maximum operating temperature 85°C.
Wall mounted hose union tap brass body incorporating a non-rising spindle headwork with a lock shield and removable butterfly handle operating member. The spout outlet incorporates a hose union connector. Maximum working pressure 16.0 bar. Maximum operating temperature 85°C.
Page 151 of 204
We use cookies to give you the best possible experience with WRAS. Some are essential to provide website functions and ensure the website is secure. We also use cookies to help us understand how people use the site and to make improvements. Click "Accept All" to enable recommended settings or click "Manage cookies" to adjust your settings. For more details, see our Cookie Policy.