Range of PFD press copper crimp fittings with EPDM ‘O’-rings for use with copper tube manufactured to EN 1057. The joints are achieved by means of a crimping tool. For above ground use. Maximum working pressure: 16.0 bar. Maximum operating temperature: 85°C
‘ZL’ range of U profile press fittings (nickel plated brass bodies) for use with ‘ZL’ range of PERT/AL/PERT multi-layered pipes. Maximum working pressure 10.0 bar. Maximum operating temperature 95°C.
Range of M profile press fit fittings with a brass body and NBR O-rings, for use with copper pipe manufactured to EN1057 and stainless-steel pipe manufactured to EN10312. Maximum working pressure: 10 Bar. Maximum operating temperature: 85°C.
‘Tectite 316’ range of push-fit fittings with stainless steel bodies incorporating EPDM ‘O’-rings for use with stainless steel tube (Grade 316 manufactured to EN 10312). Maximum working pressure: Fittings 15mm to 28mm 10.0 bar. Fittings 35mm to 54mm 6.0 bar. Maximum operating temperature 90°C.
Range of compression fitting with brass and DZR brass bodies, supplied with brass compression rings. For use with copper tube (manufactured to BS EN1057). Maximum working pressure 16.0 bar. Maximum operating temperature 85°C.
Range of float switches with plastic bodies. Cold water use only.
Range of dual flush WC outlet valves. The valves are operated via a push button assembly for either full or reduced flush and incorporates an internal overflow. Cold water use only.
Range of wall mounted gas fired condensing instantaneous water heaters. Maximum working pressure 10.0bar. Maximum operating temperature 85°C.
Range of inline and manifold water meters with brass bodies and stainless-steel strainers on the inlets. Maximum working pressure 16.0 Bar Maximum operating temperature 50.0°C
Range of ultrasonic in-line water meters with brass bodies, inlets incorporating plastic strainers. Models MA408 – DN15 & DN25 incorporate a non-return valve (not suitable for backflow prevention) at the outlet. Maximum working pressure 16.0 Bar. Maximum operating temperature 50.0°C
Water meter with a brass body. Maximum working pressure 16 Bar. Maximum operating temperature 90°C
Range of digital water meters with brass bodies. Maximum working pressure 16 Bar. Maximum operating temperature 65°C
Range of water meters (blue epoxy coated, cast iron bodies). Maximum working pressure; 16 Bar Maximum operating temperature 23°C
Range of water meters with brass bodies Maximum operating pressure 16 bar. Cold water use only.
Range of ultrasonic water meters models U-WR have brass bodies and models U-WR2 have plastic bodies. The inlets incorporate a plastic strainer. Maximum working pressure 16.0 bar. Maximum operating temperature 50⁰C.
Range of water meters with cast iron bodies (blue epoxy coating) and EPDM ‘O’ rings. Maximum working pressure 16.0 Bar Maximum operating temperature 23.0°C
Range of water meter manifolds incorporating an isolation valve, housed in a meter box. For use with PE80 pipe to BS EN 12201. Maximum working pressure 16 bar. Cold water use only.
Flow restriction valve with a brass body. Maximum working pressure 35.0 bar. Maximum operating temperature 85°C. For non-wholesome water use only.
Range of differential pressure sensors with stainless steel bodies. Maximum working pressure 16 Bar. Maximum operating temperature 85°C.
Water hammer arrestor with brass body and EPDM ‘O’ ring. Maximum working pressure 10.0 bar. Maximum operating temperature 90°C.



Range of tap outlets with chrome plated plastic bodies. Maximum operating temperature 85°C.
Concealed, floor mounted basic set with DZR brass body. For use with floor standing combination tap assemblies. Maximum operating pressure 10 bar. Maximum operating temperature 70°C
Range of click type pop-up wastes (brass or plastic bodies - various finishes, see model).
Surface mounting kit for a mono block sink mixer with stainless steel braided EPDM lined flexible hose assemblies with ½” BSP captive nut end connections. The product is supplied with a 15x15mm compression isolation valves that incorporate single check valve cartridges, however, the complete assembly has not been fully tested to demonstrate it provides backflow protection. Maximum working pressure 10.0 bar. Maximum operating temperature 85°C.
Range of single or twin shower pumps with brass bodies, brass impeller supplied with flexible connection hoses that incorporate servicing valves. Maximum Working pressure 6 Bar Maximum operating temperature 65°C
‘Hydro MPC’ range of booster sets incorporating vertical multistage centrifugal pumps, butterfly valves, non-return valves (not suitable for backflow protection), pressure transmitters, pressure gauges, lever operated spherical valves, stainless steel blanking flanges and fibre/NBR gaskets. Maximum working pressure 16.0 bar. Cold water use only. ‘Hydro MPC’ range of booster sets incorporating vertical multistage centrifugal pumps, butterfly valves, non-return valves (not suitable for backflow protection), pressure transmitters, pressure gauges, lever operated spherical valves, stainless steel blanking flanges and fibre/NBR gaskets. Maximum working pressure 16.0 bar. Cold water use only.
Range of anti-vandal shower outlets, (brass bodies – chrome plated finish), incorporating a flow regulator on the inlet. Open outlet use only Maximum operating temperature 65.0°C
Range of overhead shower outlets, (chrome plated brass bodies) incorporating flow regulators on the inlets. Model (716000) is wall mounted, all other models are ceiling mounted. Maximum operating temperature 60.0°C
Range of shower handsets and overhead showers with (plastic or chrome plated plastic bodies). Open Outlet use only Maximum operating temperature 75.0°C
Range of shower kits comprising of ABS bodied shower handsets and PVC multi-layer hoses incorporating EPDM ‘O’-rings. Supplied with riser rail. Available in various finishes. Maximum operating temperature 60°C
Range of wall mounted shower outlets (chrome plated or white finish). Products either incorporate a filter or a dummy unit for the insertion of a filter. Models 02-092034, 02-092039, 02-803150 & 02-092031 incorporate an approved check valve cartridge, however, the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum operating temperature 60°C
Shower handset with a chrome plated ABS plastic body. Maximum operating temperature 85°C.
Range of shower handsets (brass bodies – various finishes). Maximum working pressure 10.0 bar. Maximum operating temperature 85°C.
Range of in-line Y patterned strainers with flanged ductile iron bodies (blue epoxy coated) and stainless-steel mesh strainers. The strainers also incorporate a drain plug. Maximum working pressure 16.0 bar. Maximum operating temperature 85°C.
Range of in-line Y patterned strainers with bronze bodies and a stainless steel mesh strainer. Maximum working pressure 20.0 bar. Maximum operating temperature 85°C
Range of deck mounted, two hole or single hole laboratory taps (fixed or swivel) with brass bodies, incorporating rising spindle headworks with either dome type or single lever operating members. The spout outlets incorporate a hose union spigot connection and the products are supplied with a metal backnut. Maximum working pressure 10.0 bar. Maximum operating temperature 85°C.
Pillar taps (chrome plated brass bodies), incorporating quarter turn ceramic disc headworks with single lever operating members. The spout outlet incorporates a plastic flow straightener. The product is supplied with metal back nuts. Maximum working pressure 10.0 bar. Maximum operating temperature 65°C.
Range of pillar taps (chrome plated brass bodies) incorporating quarter turn ceramic disc headworks with single lever operating members. The spout outlet incorporates a plastic flow straightener or for model MIO ½ C an aerator with 4.5l flow limiter - flow limiter performance is not tested as part of the regulators specifications). The product is supplied with metal backnuts. Maximum working pressure 10.0 bar. Maximum operating temperature 65°C.
Range of pillar taps (chromium plated or matte black brass bodies) incorporating quarter turn ceramic disc headworks with single lever operating members. The spout outlets incorporate plastic flow straighteners. The products are supplied with metal backnuts. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.
Range of pillar taps (chromium plated or matte black brass bodies) incorporating quarter turn ceramic disc headworks with single lever operating members. The spout outlets incorporate plastic flow straighteners. The products are supplied with metal backnuts. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.
Self-closing pillar tap (chromium plated brass) with spring loaded headwork and dome operating member. The spout outlet incorporates a plastic aerator. Supplied with brass backnuts. Maximum working pressure 10 Bar Maximum operating temperature 85°C
Range of stainless-steel braided TPS lined flexible hose assemblies incorporating EPDM or fibre washers. The products can be supplied with a range of end connections and seals. Some models also incorporate integral isolation valves Push-fit fittings for use with: Copper Pipes manufactured in accordance with BS EN 1057 PB pipes manufactured in accordance with BS 7291-2 PEX pipes manufactured in accordance with BS 7291-3 Maximum working pressure 12.0 bar. Maximum operating temperature 65°C.
‘Qualflex Excel’ range of stainless steel over braided, PEX lined flexible hoses, incorporating EPDM or fibre washers. The products can be supplied with a range of end connections and seals. Some models also incorporate integral isolation valves. Push-fit fittings for use for with: Copper Pipes manufactured in accordance with BS EN 1057 Plastic PB pipes manufactured in accordance with BS 7291-2 Plastic PEX pipes manufactured in accordance with BS 7291-3 Maximum working pressure: 6.0 bar. Maximum operating temperature: 65°C.
Flexible safety hose assembly with PVC inner hose and corrugated outer cover incorporating EPDM gaskets. The inlet of the hose incorporates a plastic strainer. The hose is fitted with an integral device consisting of a water sensitive material which expands when in contact and is intended to stop the flow of water (please note that this function has not been verified by test). Maximum working pressure: 10.0 Bar. Maximum operating temperature: 60.0°C.
Inlet hose consisting of a EPDM inner hose layer and corrugated outer cover. The hose is fitted with an integral device consisting of a water sensitive material which expands when in contact with water. Maximum working pressure 10.0 bar. Maximum operating temperature 90°C.
Range of stainless steel or nylon braided EPDM lined flexible hose assemblies with various brass end connections. Compression connection to be used with copper pipe EN1057. Maximum working pressure 10 Bar. Maximum operating temperature 70°C.
Nylon and stainless-steel braided EPDM lined flexible hose assemblies. Maximum working pressure 10.0 bar. Maximum operating temperature 85°C
Range of stainless steel braided hoses with EPDM liner and NBR or fibre gaskets. DN13 and DN19 Maximum working pressure 10 bar. Maximum operating temperature 65°C. DN25 Maximum working pressure 10 bar. Cold water use only.
Range of stainless-steel braided EPDM lined flexible hose assemblies with various end connections. SCFA models incorporate a spherical valve. Maximum working pressure 16.0 bar. Maximum operating temperature 85°C.
Range of stainless steel or brass double interlocking, TPS lined flexible hose assemblies (various finishes) incorporating EPDM gaskets. Maximum operating temperature 60°C. Open Outlet Use Only
Page 124 of 209
We use cookies to give you the best possible experience with WRAS. Some are essential to provide website functions and ensure the website is secure. We also use cookies to help us understand how people use the site and to make improvements. Click "Accept All" to enable recommended settings or click "Manage cookies" to adjust your settings. For more details, see our Cookie Policy.