Range of deck mounted spout outlets (fixed or swivel - see model, Various finishes) incorporating a plastic flow straightener. The products are supplied with metal backnuts.
Non-metallic materials and components comply with BS6920 at 60°C
Range of spout outlets (brass bodies – various finishes) incorporating a plastic spray outlet. Maximum operating temperature 70°C. Open outlet use only.
Range of mini shock arrestors with a stainless steel body. Models with compression connections are for use with copper tube (manufactured to EN 1057). Maximum working pressure 10.0 or 15.0 bar (please refer to model). Maximum operating temperature 70°C.
Range of filter cartridges. Maximum working pressure 8.0 Bar. Cold water use only.
Range of filter cartridges. Maximum working pressure 8.0 Bar. Cold water use only.
Filter cartridge with a plastic body. Maximum working pressure 8.0 bar. Cold water use only.
Range of fohn stainless steel (SUS304/316L) crimp fittings incorporating EPDM ‘O’-rings. For use with FOHN stainless steel pipes (SUS304/316L). Maximum working pressure 16.0 bar.
Non-metallic materials and components comply with BS6920 at 85°C
Range of copper press fittings (‘M’ type crimp profile) and brass threaded adaptor fittings, for use with copper pipe (EN1057). Maximum operating pressure - 16 bar @ 30°C and 10 bar @ 95°C.
TP range of capillary solder ring copper fittings for use with copper tube EN1057, for above ground use only. Maximum working pressure: 25.0 bar. Maximum operating temperature: 85°C.
Range of plastic compression fittings incorporating polypropylene bodies& plastic pipe liners.. For use with both PE80 & PE100 pipe manufactured to BS EN 12201. Maximum working pressure 16 Bar Maximum operating temperature 23°C
Range of ‘B’ Press XL copper crimped fittings with EPDM ‘O’-rings for use with copper pipe to BS EN1057. Maximum working pressure 16.0 bar. Maximum operating temperature 85°C.
Range of copper crimped fittings with EPDM ‘O’-rings for use with copper pipe manufactured to EN1057. For above and below ground use. Maximum working pressure 16 Bar. Maximum operating temperature 99°C.
B Profile range of 316L & 304 stainless steel press fittings with EPDM ‘O’-rings for use with stainless steel pipe manufactured to EN 10312, for both above and underground use. Joints are achieved by the use of a press fitting tool. Maximum working pressure 16.0 Bar. Maximum operating temperature 85°C.
Range of copper end feed fittings for use with copper tube. For above and below ground use. Maximum working pressure 25.0 bar. Maximum operating temperature 99°C.
Range of WC dual flush drop valves operated via a two-push button assembly for either full or reduced flush and incorporates an internal overflow. Cold water use only.
Range of copper or stainless-steel brazed heat exchangers available with various number of plates as listed below. Maximum working pressure 25.0 Bar (copper brazed models). Maximum working pressure 10.0 Bar (stainless steel brazed models). Maximum operating temperature 100.0°C.
Range of water meters with brass bodies and plastic turbines. The inlet incorporates a plastic filter. Maximum working pressure 16.0 bar. Maximum operating temperatures Sizes DN15-25 models: 50°C, sizes DN32-40 models: 85°C.
Range of in-line water meters with either a brass or plastic composite body. The product incorporates a plastic strainer on the inlet. Maximum working pressure 16.0 Bar Maximum operating temperature 85.0°C
Range of in-line water meters with brass bodies. The inlets incorporate a plastic filter. The outlets incorporate a non-return valve (not intended for or suitable for backflow protection). Maximum working pressure 16.0 bar. Maximum operating temperature 50°C.
Range of VEGAPULS radar sensors for level measurement with plastic bodies. Cold water use only. Open outlet use only.
Range of ‘Thermowatt’ immersion heater elements incorporating brass or DZR heads with either a copper, stainless steel, alloy or titanium heating element and a black EPDM ‘O’-ring. Open outlet use only. Maximum operating temperature 99°C
`Prox’ and ‘Wave` ranges of sensor operated flow control devices incorporating a normally closed solenoid valve to control the flow and operated via an infra-red sensor. The inlet incorporates a stainless-steel strainer. Maximum working pressure 8 Bar Maximum operating temperature 65°C
Range of positive displacement diaphragm pumps with plastic bodies, EPDM ‘O’-rings and TPE diaphragm. The product incorporates an integral bypass relief valve. For use with John Guest LLDPE Pipe. Maximum working pressure 12.0 Bar. Maximum operating temperature 40.0°C.
Range of shower kits comprising of a chrome plated brass handset, shower hose and riser rail.
Non-metallic materials and components comply with BS6920 at 85°C
Range of overhead shower outlets, (brass bodies - various finishes. The inlets incorporate combined EPDM washers and stainless-steel strainers. Open outlet use only Maximum operating temperature 60°C
Range of wall or ceiling mounted shower outlets (chromium plated brass). All models except SH5010 incorporate a flow regulator. Open outlet use only. Maximum operating temperature 65 °C.
Range of showerheads with a plastic body (various finishes - see model) and brass connections. The A7889, A7890 and A7891 models incorporate two solenoids controlling the flow to the spray plate or a central plastic aerator. The showerhead inlet also incorporates a plastic flow regulator (except for the A7889 models). Open outlet use only. Maximum operating temperature 60.0°C
Range of shower handsets with brass bodies (various finishes). The inlets incorporate a plastic flow regulator and an approved single check valve cartridge however the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum operating temperature 85°C.
EASO range of shower head and hand showers, with ABS bodies and chromium plated finish. Open outlet use. Maximum operating temperature - 65 °C.
shower handset with chrome plated body. Open outlet use only Maximum operating temperature 85°C
Shower handset with plastic body. Maximum operating temperature 85C Open outlet use only
Non-metallic materials and components comply with BS6920 at 70°C
Range of in-line `Y` patterned strainers with brass bodies and stainless steel filters. Maximum working pressure 16 bar. Maximum operating temperature 85°C.
Range of `Y` patterned in-line strainers with black epoxy coated cast iron bodies and stainless-steel screens. Maximum working pressure 16.0 Bar Maximum operating temperature 85.0°C
Range of Y pattern strainers having either brass (899ST range) or bronze (900 range) bodies and PTFE seat washers. Maximum working pressure 20.0 Bar (Model 900), Maximum working pressure 32.0 Bar (Model 899ST). Maximum operating temperature 100.0°C.
Range of wall mounted hose union bib taps incorporating a rising spindle headwork with a T - handle operating member. Model 13.20202.G15.CP5R-8511 has a DZR brass body, all other models have a brass body. Model 13.20252.G15.CP5R-8510 incorporates a lockshield device at the base of the operating stem. The spout outlets incorporate a hose union connector. Maximum working pressure 16.0 bar. Maximum operating temperature 85°C.
Range of pillar taps, (brass bodies – various finishes), incorporating a quarter turn ceramic disc headwork with a cross top operating member. The spout outlet incorporates a plastic aerator. The product is supplied with metal backnuts. Maximum working pressure 10.0 Bar Maximum operating temperature 60.0°C
Range of TPE shower hoses (various finishes) with EPDM seals. Open outlet use only. Maximum operating temperature 60.0°C
Range of stainless steel or brass double interlocking, TPS lined flexible hose assemblies (various finishes) incorporating EPDM gaskets. Maximum operating temperature 60°C. Open Outlet Use Only
Stainless steel interlocked (chrome plated) silicone lined kitchen tap pull-out hose. Open outlet use only. Maximum operating temperature 85°C.
Range of Ultraflow Air bubble top indirect and direct single coil unvented storage cylinders. The secondary circuit is factory fitted with a temperature and pressure relief valve set at 10.0 bar@90˚C. A safety kit (manifold) consisting of a single check valve assembly, verified by test (suitable for backflow prevention against fluid category 2), strainer, an expansion relief valve set at 8.0 bar and a pressure reducing valve set at 3.0 bar and a tundish is also provided. Alternative inlet control group and temperature and pressure relief valve added January 2023. Maximum working pressure: Secondary circuit: 7.5 bar. Primary circuit: 6.0 bar.
Non-metallic materials and components comply with BS6920 at 65°C
Range of unvented storage cylinders. The secondary circuit is factory fitted with a temperature and pressure relief valve set at 6.0 bar at 95˚C and an expansion relief valve set at 4.5 bar. The product is supplied with a safety group consisting of a pressure reducing valve set at 3.0 bar, and an approved check valve cartridge, however, the complete product has not been fully tested to demonstrate it provides backflow protection). Also supplied with an expansion vessel and tundish. Maximum working pressures: Secondary circuit: 4.0 Bar Primary Circuit: 3.0 Bar Solar circuit: 6.0 Bar Maximum operating temperature 99.0°C
Range of unvented storage cylinders. The secondary circuit is factory fitted with a temperature and pressure relief valve set at 6.0 bar at 95˚C and an expansion relief valve set at 4.5 bar. The product is supplied with a safety group consisting of a pressure reducing valve set at 3.0 bar, and an approved check valve cartridge, however, the complete product has not been fully tested to demonstrate it provides backflow protection. Also supplied with an expansion vessel and tundish. Maximum working pressures: Secondary circuit: 4.0 Bar Primary Circuit: 3.0 Bar Solar circuit: 6.0 Bar Maximum operating temperature 99.0°C
Range of unvented storage cylinders. The secondary circuit is factory fitted with a temperature and pressure relief valve set at 6.0 bar at 95˚C and an expansion relief valve set at 4.5 bar. The product is supplied with a safety group consisting of a pressure reducing valve set at 3.0 bar, and an approved check valve cartridge, however, the complete product has not been fully tested to demonstrate it provides backflow protection. Supplied with an expansion vessel and tundish. Maximum working pressures: Secondary circuit: 4.0 Bar Primary Circuit: 3.0 Bar Solar circuit: 6.0 Bar Maximum operating temperature 99.0°C
Range of unvented storage cylinders. The secondary circuit is factory fitted with a temperature and pressure relief valve set at 6.0 bar at 95˚C and an expansion relief valve set at 4.5 bar. The product is supplied with a safety group consisting of a pressure reducing valve set at 3.0 bar, and an approved check valve cartridge, however, the complete product has not been fully tested to demonstrate it provides backflow protection. Supplied with an expansion vessel and tundish. Maximum working pressures: Secondary circuit: 4.0 Bar Primary Circuit: 3.0 Bar Solar circuit: 6.0 Bar Maximum operating temperature 99.0°C
Range of single/double orifice air venting valves with blue epoxy coated ductile iron bodies, and a stainless-steel float ball. Incorporating EPDM washers. Maximum working pressure 16.0 Bar. Maximum operating temperature 80.0°C.
Range of manually operated flow control valves with (brass bodies - various finishes), incorporating either a non-rising spindle headwork or (quarter turn ceramic disc headwork model 16 973 180 only) with cross top, lever or dome type operating members. Maximum working pressure; 10Bar Maximum operating temperature 70°C
Range of wall mounted, thermostatic bar shower mixers (brass bodies – various finishes), incorporating a quarter turn ceramic disc headwork that controls the flow with a dome type operating member. Temperature is controlled independently via a thermostatic cartridge with dome type operating member that incorporates a manual override button. Models 801524.001 & 801540.001 incorporate a half turn ceramic disc headwork that diverts the flow to an overhead shower or shower handset. Both inlets incorporate an approved check valve cartridge and stainless steel strainers however, the complete product has not been fully tested to demonstrate it provides backflow protection. Models 801508.001 & 801508.002. Maximum working pressure 10 bar. Maximum operating temperature 65 C. Model 801509.001. Maximum working pressure 10 bar. Maximum operating temperature 60 C. Model 801524.001. Maximum working pressure 5 bar. Maximum operating temperature 60 C. Model 801540.001. Maximum working pressure 5 bar. Maximum operating temperature 65 C.
Wall mounted, exposed shower valve which has a brass body, available in different finishes. Flow is controlled by a quarter turn ceramic disc headwork with dome operating member and temperature is controlled independently via a thermostatic cartridge with dome type operating member. The inlets incorporate a single check valve cartridge however, the complete assembly has not been fully tested to demonstrate that it provides backflow protection Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.
Range of wall mounted thermostatic bar shower mixers with brass bodies, incorporating a thermostatic cartridge controlling the temperature and non-rising spindle headwork controlling the flow. The inlets incorporate stainless steel strainers and an approved check valve cartridge; however, the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum working pressure 5.0 bar. Maximum operating temperature 85°C.
Range of T-type thermostatic mixing valves with brushed chrome plated DZR brass bodies for use with copper pipe (manufactured to BS EN 1057). All inlets incorporate stainless steel strainers. Maximum working pressure 10.0 bar. Maximum operating temperature 85°C.
Page 111 of 158
We use cookies to give you the best possible experience with WRAS. Some are essential to provide website functions and ensure the website is secure. We also use cookies to help us understand how people use the site and to make improvements. Click "Accept All" to enable recommended settings or click "Manage cookies" to adjust your settings. For more details, see our Cookie Policy.