Range of five-hole, single outlet (fixed) combination tap assemblies with brass or stainless steel bodies in various finishes. The products incorporate a ceramic cartridge headwork controlling both the temperature and flow to the shower handset, and a quarter turn ceramic disc headwork controlling the flow via a thermostatic cartridge to the spout outlet. All have single lever operating members. Some models are supplied with a spout outlet which incorporates a plastic aerator. Some models are supplied with a shower hose and handset. The inlet to the spout assembly and the inlet of the shower handset each incorporate a single check valve cartridge however, the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.
Range of five-hole, single outlet (fixed) combination tap assemblies with a brass body, incorporating quarter turn ceramic disc headworks with single lever or cross top operating members. The products have a self-cancelling operated diverter to shower outlet and are supplied with a shower hose, shower handset and interconnecting braided hoses. The spout outlet incorporates a plastic flow aerator. Maximum working pressure 5 bar. Maximum operating temperature 60°C.
Range of deck mounted swivel spout outlets (brass bodies – chrome plated) incorporating aplastic flow straightener. The products are supplied with plastic back nuts. Maximum working pressure 5.0 bar Maximum operating temperature 60.0°C
Zilmet range of cylindrical or tubular expansion vessels, epoxy coated carbon steel bodies with either Butyl or EPDM membranes and stainless-steel or galvanized carbon-steel connections. Please refer to models for maximum working pressures, as this varies by model and size. Maximum operating temperature 65°C.
Range of filling loop assemblies, consisting of: A nickel plated DZR brass bodied isolation valve with chrome plated DZR brass ball and integral non-verifiable double check valve assembly, verified by test (suitable for backflow protection against Fluid Category 3). A stainless-steel braided EPDM lined flexible hose assembly. An isolation valve with a nickel plated DZR brass body and a chrome plated DZR brass ball. The HLD14.12.049 model is supplied with a lanyard and cap end for each valve. The compression connections are for use with copper pipe (manufactured to BS2871). Maximum working pressure 10.0 Bar. Maximum operating temperature 85°C.
Range of in-line carbon block water filters and housings with polypropylene bodies. Maximum working pressure 8.0 bar. Cold water use only.
Range of filter cartridges and housings with plastic bodies (various finishes, see models), EPDM O-rings and PSF membrane. The inlets incorporate an approved check valve cartridge however, the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum operating pressure 6 bar. Maximum operating temperature 50.0°C.
Range of filter cartridges. Maximum working pressure 8.0 Bar. Cold water use only.
‘Polyplumb’ plastic compression and push-fit fittings for use with polyethylene pipe (Polyguard PE80 ‐PE/AL/PE‐barrier pipe to BS8588), Polyplumb barrier pipe (to BS7291) & Copper pipe (to BS EN 1057). Inserts must be used to accommodate the Polyplumb Barrier pipes. For above and below ground use. Maximum working pressure: 12.5bar. Cold water use only.
Range of AIS tin-plated brass and PPSU press fit fittings for use with WRW & 'Maincor MLC’ multi layered PE-RT/AL/PE-RT pipe. Maximum working pressure 10.0 bar. Maximum operating temperature 70°C.
Range of copper, bronze or DZR brass capillary solder ring fittings for use with copper pipe (manufactured to EN 1057). Maximum working pressure and operating temperatures: 8-28mm: 25.0 bar @ 30°C, 16.0 bar @ 100°C. 35-54mm: 25.0 bar @ 30°C, 16.0 bar @ 65°C and 10.0 bar @ 100°C.
Range of WC flush valves with an ABS body and silicon seal. The valves are operated via a push button assembly for either full or reduced flush and incorporate an internal adjustable height overflow. Cold water use only.
Range of copper brazed, stainless steel heat exchangers available with between 4 & 70 plates. Maximum working pressure 50 bar. Maximum operating temperature 100°C
Wall mounted electric instantaneous water heater. The inlet incorporates a plastic flow sensor with strainer. Maximum working pressure 6.0 Bar Maximum operating temperature 55.0°C
Range of wall mounted combination boilers providing domestic hot water via a plate heat exchanger and pressurised central heating system. The primary circuit incorporates a pressure relief valve set at 3.0 bar and an expansion vessel. The secondary circuit (DHW) incorporates a plastic flow restrictor and stainless-steel filter. The primary and secondary circuit incorporates isolation valves on the flow and the primary also has one on the return. Maximum working pressures: Secondary DHW: 10.0 Bar Primary CH: 2.5 Bar Maximum operating temperatures: Secondary DHW: 65.0°C Primary CH: 85.0°C
Range of water meters with blue epoxy coated ductile iron bodies, plastic measurement chambers and vanes and NBR ‘O’-rings. Maximum working pressure 16.0 bar. Maximum operating temperature 50°C.
Range of pressure reducing valve assemblies with brass bodies incorporating spherical stop valve, pressure gauge and double check valve cartridges, verified by test (suitable for backflow protection against Fluid Category 3). Models TVAP250001 & TVAP250005 also incorporate a water meter port. Maximum supply pressure 16 bar. Outlet pressure setting is adjustable in the range 1.5 to 6 bar. Maximum operating temperature 65°C
Water meter manifold assembly with gunmetal body, incorporating a servicing valve and a single check valve cartridge, however, the complete product has not been fully tested to demonstrate it provides backflow protection. Max operating pressure 16 bar Maximum operating temperature Cold water only
Range of water meter housings. The 4414-WMH-20 (threaded) model has a DZR brass body and a check valve cartridge on the inlet verified by test (suitable for backflow protection against Fluid Category 2). The 4414-WMH-1 & 4414-WMH-2 (compression) models have a brass body and an approved check valve cartridge on the inlet, however, the complete product has not been fully tested to demonstrate that it provides adequate backflow protection. The compression models are for use with copper pipe (manufactured to EN 1057). Maximum operating pressure 16.0 bar. Maximum operating temperature 85°C.
Range of wall & floor mounted, two hole, single outlet combination tap assemblies with brass bodies incorporating ceramic cartridge headworks with single lever operating members. Spout incorporates a plastic aerator. Products also incorporate an approved check valve cartridge, however, the complete product has not been fully tested to demonstrate it provides backflow protection. The products are supplied with shower hose and handset. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.
Range of medical shower handsets incorporating plastic bodies and EPDM O-rings with various inserts. Supplied with PVC/PEX lined shower hoses incorporating EPDM washers. Maximum operating temperature 65°C. Open outlet use only
Range of wall mounted shower outlets with chromium plated brass body. The product incorporates a stainless steel strainer, plastic flow regulator and an approved single check valve cartridge; however, the complete product has not been fully tested to demonstrate it provides backflow protection. Open outlet use only. Maximum operating temperature 65.0°C.
Range of shower arms, hand shower holders and wall outlet with brass bodies (various finishes). Maximum working pressure: Open outlet. Maximum operating temperature: 60°C.
Range of shower panel units incorporating an overhead shower outlet. Flow is controlled via spring-loaded headworks using a push-button mechanism. The shower outlet connection incorporates an approved single check valve cartridge; however, the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum working pressure 5.0 bar. Maximum working temperature 60°C.
Ceiling mounted multispray rain shower outlet. Open outlet. Max operating Temperature 60 °C
Range of shower handset with chrome plated or white plastic bodies. Colour coding discs are located on the face plates of specific models. Maximum operating temperature 60°C
Range of shower handsets with either a white or chrome plated plastic body. Maximum operating temperature 45°C.
Range of overhead shower outlets with chromium plated plastic bodies. The inlets incorporate combined EPDM washers and stainless-steel strainers. Maximum working pressure: open outlet use only Maximum operating temperature 60°C
Range of shower arms and ceiling connectors (brass bodies – various finishes) & overhead shower outlets (plastic bodies - various finishes), incorporating EPDM O rings, plastic flow regulators and stainless-steel strainers. Open outlet use only Maximum operating temperature 60.0°C
Range of shower arms and ceiling connectors (brass bodies – various finishes) & overhead shower outlets (plastic bodies - various finishes), incorporating EPDM O rings, plastic flow regulators and stainless-steel strainers. Open outlet use only. Maximum operating temperature 60.0°C
Range of shower riser kits and shower cradle kits. Models PSA006, PSA013, PSA007, PSA012, PSA002, PSA004, also incorporate a manual operated diverter with single lever operating member. Maximum operating temperature 65.0°C
Hand shower outlet with plastic bodies (various finishes, see models) incorporating a PSF membrane filter and EPDM O-rings. The inlets incorporate an approved check valve cartridge however, the complete product has not been fully tested to demonstrate it provides backflow protection. Open outlet use only. Maximum operating temperature: 50°C.
Range of in-line `Y` patterned strainers with brass bodies and stainless steel filters. Maximum working pressure 16 bar. Maximum operating temperature 85°C.
Wall mounted bib tap (chrome plated brass), incorporating a non-rising spindle headwork with a cross top operating member. The spout outlet incorporates a plastic flow straightener. Maximum working pressure 10 bar. Maximum operating temperature 65°C.
Range of drain valves with bronze bodies, EPDM seat and ‘O’-rings. The products incorporate a rising spindle operating mechanism and a hose union outlet connection. Maximum working pressure 10.0 bar. Maximum operating temperature 100°C.
Range of drain taps with brass or DZR brass body (some models chrome plated) and rising spindle headwork. Maximum working pressure 16.0 bar. Maximum operating temperature 85°C.
Range of wall mounted hose untion taps with chrome plated brass body and spindle headwork with dome type operating member. Maximum operating pressure 10.0 bar. Cold water use only.
Range of pillar taps, (chrome plated brass bodies) incorporating non-rising spindle headworks with dome or cross-top type operating members. Model (C58118) incorporate quarter turn ceramic disc headworks with single lever operating members. The spout outlets incorporate plastic flow straighteners. The product is supplied with metal backnuts. Maximum working pressure 10.0 bar. Maximum operating temperature 65°C.
Pillar tap with (brass body - various finishes) incorporating a quarter turn ceramic disc headwork situated on the spout outlet with a cylinder type operating member. The spout outlet incorporates a plastic spray disc and a flow regulator. Maximum working pressure 10.0 Bar Maximum operating temperature 60.0°C
Range of nylon or stainless steel braided flexible hose assemblies incorporating a PE-X inner hose, EPDM ‘O’-rings and/or gaskets. Maximum working pressure 10.0 bar. Maximum operating temperature 85°C.
Range of PVC lined shower hoses with silicone rubber gaskets and interlocked chromium plated outer coating. For open outlet use only. Maximum operating temperature 65°C.
Stainless steel interlocked shower hose with PVC inner hose and EPDM O-rings, various finishes. Open outlet use only. Maximum operating temperature 65°C.
Range of stainless-steel braided EPDM lined flexible hose assemblies with EPDM seals, available with a variety of end connections, some of which include isolation valves (see model). Maximum working pressure 10 Bar. Maximum operating temperature 85°C
Range of stainless steel braided, EPDM lined flexible hose assemblies. Models are available with a variety of end connections. Maximum working pressure 10.0 bar. Maximum operating temperature 85°C
Range of indirect and direct unvented storage cylinders. The secondary circuit is factory fitted with a temperature and pressure relief valve set at 7.0 bar @ 90˚C. The product is supplied with an inlet control group (safety kit) consisting of a pressure reducing valve pre-set at 3.0 bar, strainer, an expansion relief valve set at 6.0 bar and an approved check valve cartridge (verified by test - suitable for backflow protection against Fluid Category 2). A tundish and expansion vessel are also provided. Maximum working pressures: Primary: 3.0 Bar Secondary: 5.5 Bar Solar: 3.0 bar Maximum operating temperature 90.0°C
Range of wall mounted, manual blending valves, (brass bodies – various finishes), incorporating a ceramic disc headwork controlling the flow with a dome type operating member, temperature is controlled via a ceramic cartridge with a dome type operating member. Model 12 670 xx0 is supplied with a shower hose, handset and overhead shower. The outlet to the shower hose incorporates an approved check valve cartridge, however, the complete product has not been fully tested to demonstrate it provides backflow protection. The shower handset inlet incorporates a plastic flow regulator. Maximum working pressure 10.0 Bar Maximum operating temperature 65.0°C
Range of wall mounted, concealed, bath-shower mixer valves (brass bodies, chromium plated trim sets) incorporating a ceramic cartridge headwork with single lever operating members and a manual diverter to two outlets. Maximum working pressure 10 bar. Maximum operating temperature 60°C
Range of wall mounted, thermostatic blending valves (brass bodies – various finishes), incorporating a ceramic disc headwork controlling the flow with a dome type operating member, temperature is controlled via a thermostatic cartridge with a dome type operating member incorporating a manual override button. The product is supplied with a shower hose, handset and overhead shower. The outlet to the shower hose incorporates an approved check valve cartridge, however, the complete product has not been fully tested to demonstrate it provides backflow protection. The shower handset inlet incorporates a plastic flow regulator. Maximum working pressure 10.0 Bar Maximum operating temperature 65.0°C
Range of wall mounted, concealed, thermostatic blending valves with brass bodies in various finishes. The flow is controlled via ceramic disc or push-button headwork with dome type operating member. The temperature is controlled independently via a thermostatic cartridge with a dome type operating member. The inlets incorporate an approved check valve cartridge however, the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C
Range of wall mounted, thermostatic blending valves, (brass bodies various finishes), incorporating a quarter turn ceramic disc headwork controlling the flow.Temperature is controlled independently via a thermostatic cartridge with a manual override button incorporating dome or lever type operating members, Each inlet incorporates a stainless-steel strainer and an approved check valve cartridge; however, the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.
Page 105 of 209
We use cookies to give you the best possible experience with WRAS. Some are essential to provide website functions and ensure the website is secure. We also use cookies to help us understand how people use the site and to make improvements. Click "Accept All" to enable recommended settings or click "Manage cookies" to adjust your settings. For more details, see our Cookie Policy.