Rainwater top up cistern with flow controlled by solenoid valve and discharged via a type `AB` airgap (verified by test - suitable for backflow protection against fluid category 5). Product also incorporates a stop valve, a flow restrictor and a float valve on the inlet. Maximum working pressure 10.0 bar. Cold water use only.
‘Calomax Eclipse’ range of electrically heated counter top or wall mounted catering water boilers. The boilers incorporate a stainless steel cold water feed cistern which has a combined vent/overflow fitted with an insect screen. The water to the cistern is supplied via a solenoid valve which incorporates an approved check valve cartridge, however, the complete product has not been fully tested to demonstrate it provides backflow protection. The water level is electronically controlled via level sensors. The water is dispensed via a manually operated brass bodied (chrome plated)/stainless steel bodied self-closing tap(s) or a push button controlling a solenoid valve prior to the outlet. The counter top models are supplied with a PVC coated flexible inlet hose (¾” BSP (F) x 15mm standpipe) and a push fit adaptor (15mm push fit x ¾ BSP (F)). Maximum working pressure 10.0 bar (to the solenoid valve). Maximum temperature of dispsensed water 90°C for PB3C10 & PB3W5 models and 97°C for all other models. Cold water supply only.
Range of boiling water dispensers incorporating plastic (3-7.5 litre models) or stainless steel (10-40 litre models) cisterns with silicone ‘O’-rings and seals. The flow to the internal reservoir is controlled via a float valve. The internal reservoir incorporates an overflow which acts a vent. The inlet incorporates a plastic filter. Water is dispensed using either a lever or push button (PLUS models only) operated self-closing tap. Maximum working pressure 5.0 bar. Maximum operating temperature 98°C. Cold supply only.
Undercounter boiling water cistern with a stainless steel body, stainless steel element and silicone ‘O’-rings and gaskets. Maximum working pressure 8.0 bar. Maximum operating temperature 95°C.
Range of fittings for use with cisterns storing wholesome water. Consisting of screened tank overflows, a screened tank breather, two-way expansion pipe tee piece, tank lid adaptor and tank connections. Where products are screened they comprise of a stainless steel mesh. Maximum operating temperature 70°C.
‘Polytank’ wholesome water kit for use with water storage cisterns for domestic purposes. The products have black plastic bodies and consist of a warning pipe elbow incorporating a (white plastic) screen, breather incorporating a (white plastic) screen, vent pipe incorporating a (white plastic) screen, dip tube, plastic washer and backplate. Cold water use only.
Range of insulated, black coloured polyethylene storage cisterns suitable for storing non-wholesome water. The cisterns incorporate an AB air gap arrangement with a meshed weir overflow arrangement. The cisterns are supplied with a float valve and blue plastic float. Cold water use only.
`Silverline` range of sectional hot-pressed GRP cold water storage cisterns with butyl seals and stainless-steel bolts and tie rods. Supplied with WRAS approved byelaw 30 kits Cold water use only.
ANP range of pre insulated one piece contact moulded GRP cold water storage cisterns and covers. Supplied with a wholesome water kit, consisting of a screened vent, screened warning pipe and screened overflow pipe. Cold water use only.
Brimar IFB, EFB and TIF range of GRP sectional, pre-insulated cold water storage cisterns fitted with screened breather, overflow and warning pipe. Cold water use only.
Range of insulated, black coloured polyethylene storage cisterns, The cisterns are supplied with a wholesome water kit consisting of a screened warning pipe elbow, vent, vent pipe, dip tube, plastic washer and backplate. Cold water use only.
Range of pre insulated hot press moulded GRP sectional cisterns with butyl seals and stainless-steel bolts. Cisterns are supplied with a float operated inlet valve, screened overflow and screened vent. Cold water use only.
Range of one-piece and two-piece pre-insulated GRP cold water storage cisterns. Cisterns are supplied with a float operated inlet valve, screened overflow and screened vent. Cold water use only.
Liquistore range of circular sectional cisterns with galvanised or aluminium panels and a butyl inner liner. Supplied with a float operated inlet valve, screened breather, screened overflow and a gate valve on the drain connection. Cold water use only.
Range of one piece water storage cisterns with a screened breather and over flow. Cold water only.
Range of hot-pressed sectional cold water storage cisterns for wholesome water. The cisterns can either be galvanised or primed and site coated and are fitted with a float operated valve, screened air vents, overflow pipe and breather. The cisterns can also be fitted with a coated, carbon steel ladder. Cold water use only.
Range of insulated, black coloured polyethylene storage cisterns, The cisterns are supplied with a wholesome water kit consisting of a screened warning pipe elbow, vent, vent pipe, dip tube, plastic washer and backplate. Cold water use only.
Range of one piece water storage cisterns with a screened breather and over flow. Model 46714 iBoost+200 has a rectangular weir overflow Model 46712 iBoost+200 has a circular overflow Cold water only.
One & two piece ranges of pre insulated GRP cold water storage cisterns with a butyl sealant. Supplied with a screened breather. Cold water use only.
One-piece (white) HDPE plastic storage cistern with lid. Maximum operating temperature 60°C.
Range of hot pressed moulded GRP sectional cold water storage cisterns. Larger cisterns are fitted with PVC roof supports and are supplied with stainless steel ladders, tie rods, braces and hatches. Cold water use only.
M100 & M100-B30 ranges of hot press moulded GRP sectional, pre-insulated, cold water storage cisterns. The cisterns are sealed with butyl rubber and are supplied with a float operated valve (gunmetal or DZR brass body depending on size). The rooves are fitted with one or more sealed manhole access points, which can also be fitted at low level if required. Larger cisterns are fitted with stainless steel ties, GRP roof struts & GRP ladders. The M100-B30 models are supplied with a screened tank overflow, a screened tank breather, two-way expansion pipe tee piece, tank lid adaptor and tank connections. Models can also be supplied with access doors. Maximum working pressure of supplied inlet valve: Gunmetal body inlet valves 5.0 bar, DZR brass body inlet valves 10.0 bar. Cold water use only.
Range of sectional stainless steel storage cistern with lid. Maximum operating temperature 60°C.
Range of sectional stainless steel storage cistern with lid. Maximum operating temperature 60°C.
Range of open or closed top, circular, sectional, cold water storage cisterns with corrugated & galvanised steel bodies and an EPDM liner.
‘Comisa’ range of brass bodied press-fit and threaded fittings for use with `Comisa’ (PE-RT/AL/PE-LMD) multi-layer pipe. Maximum working pressure 10.0 bar. Maximum operating temperature 95°C.
Geberit range of ‘FlowFit’ press Fittings for use with ‘Geberit FlowFit Pipe ML’ and ‘Geberit FlowFit Pipe coils ML’ (insulated and uninsulated) PERT/Al/PERT pipes. The fittings are made from PPSU or lead free silicon bronze. Operating parameters: 16.0 bar@cold water and 10.0 bar@70°C.
Range of tank and cistern connectors, with push fittings. Models CM0715S and CM0722S are for use with copper tube (manufactured to BS EN 1057) PE-X pipe (BS7291-3) & PB pipe (BS7291-2). Until April 2023, model CM0728S was only for use with copper tube (manufactured to BS EN 1057). From May 2023, model CM0728S is also for use with PE-X pipe (BS7291-3) & PB pipe (BS7291-2). Cold water use only.
Range of WC flapper valves with a silicone seal, ABS body and internal overflow. The device is operated via a plastic chain to be connected to a cistern handle. Cold water use only.
Dual flush, WC outlet valve with internal overflow, operated via a push button assembly for either full or reduced flush. Cold water use only.
‘Turbo 88R Duo Flush Adjustable Syphon’ syphonic flushing apparatus with Polypropylene body and stainless steel link for use with WC flushing cisterns.
Dudley S9 dual flush syphonic flushing apparatus with a polypropylene body and stainless steel link for use with WC flushing cisterns.
Turbo 44R dual flush syphonic flushing apparatus with a polypropylene body and stainless steel link for use with WC flushing cisterns.
Turbo S1-11 Dual Flush syphonic flushing apparatus with Polypropylene body and stainless steel link for use with WC flushing cisterns.
Flapper valve with a polypropylene connection arm and a flexible PVC seal. The device is operated via a stainless-steel chain connected to a cistern handle. Cold water use only.
Turbo 88R Duo lush syphonic flushing apparatus with polypropylene body and stainless-steel link for use with WC flushing cisterns.
WC. Except where specified, flushing valves within this section have only completed a limited number of the performance and endurance tests as stated in the "Regulators Specification for WC suites installed after 1st January 2001". The flush volume of valves within this section have not be verified by test. When installed in combination with a WC cistern and pan, further performance tests will be required.
Pent-A-Boost domestic break tank and booster set incorporating a single or dual pump stage pump set assembly and break cistern (incorporating an AG air gap arrangement). Inlet level sensors control the water supply via solenoid valves with inline strainers fitted (see manufacturers data sheet for optional arrangements). The unit also incorporates an expansion vessel. Flow from the break tank is via a single check valve suitable for fluid category 2 to a booster pump arrangement (see manufacturers data sheet for optional arrangements). Maximum working pressure 10 bar. Cold water use only.
Range of cold water in tank booster sets incorporating an ‘AG’ air gap, consisting of a GRP water storage cistern incorporating a float operated inlet valve, with a copper float and submersible pump or pumps (depending on model). The products incorporate an externally mounted stainless-steel manifold with servicing valve(s), expansion vessel, pressure gauge and a digital control panel. The pumps are connected to the external components via a discharge assembly of internal pipework including an in-line non-verifiable single check valve assembly (suitable for backflow prevention of Fluid Category 2). Maximum working pressure 10.0 bar. Cold water use only.
Range of cold water in tank booster sets incorporating an ‘AB’ air gap, consisting of a GRP water storage cistern incorporating a float operated inlet valve, with a copper float and submersible pump or pumps (depending on model). The products incorporate an externally mounted stainless-steel manifold with servicing valve(s), expansion vessel, pressure gauge and a digital control panel. The pumps are connected to the external components via a discharge assembly of internal pipework including an in-line non-verifiable single check valve assembly (suitable for backflow prevention of Fluid Category 2). Maximum working pressure 10.0 bar. Cold water use only.
Range of water pressure booster sets with a cold water storage cistern and booster pump. All models incorporate a non-return valve, not suitable for backflow protection. These models have an AG air gap suitable for fluid category 3 protection. Maximum working pressure 6.0 bar. Cold water use only.
Range of water pressure booster sets with a cold water storage cistern and booster pump. All models incorporate a non-return valve, not suitable for backflow protection. These models have an AB air gap suitable for fluid category 5 protection. Maximum working pressure 6.0 bar. Cold water use only.
Range of servicing valves incorporating brass bodies (chrome plated or natural brass) The P2290 & P2290SI models are spherical valves with brass balls. The 201210 A-80 model is quarter turn with an EPDM seat and ‘O’-ring. The NF721 & NF721SI models are quarter turn with a NBR seat and EPDM ‘O’-ring. The 00711 A-80 is quarter turn with a NBR seat and ‘O’-rings. Maximum working pressure 16.0 bar. Cold water use only.
'Sealcoat Black'. Black coloured, factory applied petroleum bituminous coating. Apply as per manufacturer's instructions for use reference 'PC 819' dated March, 26, 2021. Cure for 18 hours at 30°C. For use with water up to 23°C. This material is only approved for the curing conditions that appear on the approval. If the cure conditions are varied from those specified on the approval then the material is not covered by the scope of the approval. Petroleum or asphaltic bitumen, NOT coal tar bitumen. Materials listed in this section are not approved for use for contact with water that is required to be wholesome on large water retaining structures such as lining of pipes, cisterns or water storage tanks.
‘Inertol BS10’. Factory applied, black coloured bitumen coating. Apply as per manufacturer’s technical data sheet 'no. 786.3' dated 2013-V2'. Cure for 5 hours@23°C or 30 minutes@50°C. For use with water up to 60°C. This material is only approved for the curing conditions that appear on the approval. If the cure conditions are varied from those specified on the approval then the material is not covered by the scope of the approval. Petroleum or asphaltic bitumen, NOT coal tar bitumen. Materials listed in this section are not approved for use for contact with water that is required to be wholesome on large water retaining structures such as lining of pipes, cisterns or water storage tanks.
‘Inertol BS10’. Factory applied, black coloured bitumen coating. Apply and cure as per manufacturer’s instructions 'BF-T06', issue number '03' dated 01.12.2021. For use with water up to 60°C. Petroleum or asphaltic bitumen, NOT coal tar bitumen. Materials listed in this section are not approved for use for contact with water that is required to be wholesome on large water retaining structures such as lining of pipes, cisterns or water storage tanks.
'Kubotaseal BM'. Factory applied, black coloured asphaltic bituminous coating. Apply as per manufacturer's PDS reference `11004T-1.4' dated Feb, 20, 2020. Cure 6 hours@20°C. For use with water up to 60°C. Materials listed in this section are not approved for use for contact with water that is required to be wholesome on large water retaining structures such as lining of pipes, cisterns or water storage tanks. This material is only approved for the curing conditions that appear on the approval. If the cure conditions are varied from those specified on the approval then the material is not covered by the scope of the approval.
Bidet seat assembly which discharges via a sensor actuated solenoid valve and utilises a ‘Type AD’ air gap arrangement (suitable for backflow prevention against Fluid Category 5). The inlet incorporates a strainer and flow regulator (not verified by the test facility) and is pumped from an internal water storage cistern via a heating unit to various outlet nozzle arrangements. Maximum working pressure 10 bar. Cold water supply only.
Bidet seat assembly which discharges via a sensor actuated solenoid valve and utilises a ‘Type AD’ air gap arrangement (suitable for backflow prevention against Fluid Category 5). The inlet incorporates a strainer and flow regulator (not verified by the test facility) and is pumped from an internal water storage cistern via a heating unit to various outlet nozzle arrangements. Maximum working pressure 10 bar. Cold water supply only.
Bidet seat assembly which discharges via a sensor actuated solenoid valve and utilises a type `AB` airgap (verified by test - suitable for backflow protection against fluid category 5). The inlet incorporates a strainer and flow regulator and is pumped from an internal water storage cistern via a heating unit to various outlet nozzle arrangements. Maximum working pressure 10.0 bar. Cold water supply only.
Bidet seat assembly which discharges via a sensor actuated solenoid valve and utilises a type `AB` airgap (verified by test - suitable for backflow protection against fluid category 5). . The inlet incorporates a strainer and flow regulator (not verified by the test facility) and is pumped form an internal water storage cistern via a heating unit to various outlet nozzle arrangements. Maximum working pressure 10.0 bar. Cold water supply only.
BS1212-4 (2016) compact type float operated valve for WC flushing cisterns, bottom entry type with plastic ½’’ BSP inlet. The inlet incorporates a stainless steel strainer and a plastic flow restrictor. Cold water use only. Maximum working pressure10.0 bar
Bottom entry BS1212-4 (2016) delayed action type float operated valve for WC flushing cisterns. Maximum working pressure 10.0 bar. Cold water use only.
Side entry BS1212-4 (2016) delayed action type float operated valve for WC flushing cisterns. Maximum working pressure 10.0 bar. Cold water use only.
Vertical and side entry BS1212-4 (2016) compact type float operated inlet valve for WC flushing cisterns with a plastic body and adjustable float, EPDM ‘O’-rings and a plastic flow regulator at the inlet. Maximum working pressure 10.0 bar. Cold water use only.
Bottom entry BS1212-4 (2016) compact type float operated inlet valve for WC flushing cisterns with a plastic body and adjustable float, EPDM ‘O’-rings and a plastic flow regulator at the inlet. Maximum working pressure 10.0 bar. Cold water use only.
Bottom entry BS1212-4 (2016) compact type float operated valve for WC flushing cisterns. The inlet incorporates a plastic strainer. Maximum working pressure 10.0 bar. Cold water use only.
Range of side entry BS1212-4 (2016) delayed action or non-delayed action type float operated valves for WC flushing cisterns. The inlet incorporates an optional flow restrictor. Maximum working pressure 10.0 bar. Cold water use only.
Side entry BS1212-4 (2016) compact type float operated valve for WC flushing cisterns. The inlet incorporates a strainer. Maximum working pressure 10.0 bar. Cold water use only.
Side entry BS1212-4 (2016) compact type float operated valve for WC flushing cisterns. The inlet incorporates a plastic filter. Maximum working pressure 10.0 bar. Cold water use only.
Range of bottom entry BS1212-4 (2016) compact type float operated valves for WC flushing cisterns with delayed action. . The inlet incorporates a flow restrictor. Maximum working pressure 10.0 bar. Cold water use only.
Range of bottom entry BS1212-4 (2016) compact type float operated valves for WC flushing cisterns. The inlet incorporates a plastic strainer. Maximum working pressure 10.0 Bar. Cold water use only.
Bottom entry BS1212-4 (2016) compact type float operated valve for WC flushing cisterns. The inlet incorporates a flow restrictor. Maximum working pressure 10.0 bar. Cold water use only.
Bottom entry BS1212-4 (2016) compact type float operated valves for WC flushing cisterns. The inlet incorporates a strainer. Maximum working pressure 10.0 bar. Cold water use only.
Side entry BS1212-4 (2016) compact type float operated valve for WC flushing cisterns. Maximum working pressure 10.0 bar. Cold water use only.
BS1212-4 (2016) compact type float operated valve for WC flushing cisterns, bottom entry type with plastic ½’’ BSP inlet. The inlet incorporates a stainless steel strainer and a plastic flow restrictor. Cold water use only. Maximum working pressure10.0 bar
Range of bottom entry BS1212-4 (2016) compact type float operated valve for WC flushing cisterns. The inlet incorporates a plastic strainer. Maximum working pressure 10.0 Bar. Cold water use only.
Side entry BS1212-4 (2016) compact type float operated valve for WC flushing cisterns. The inlet incorporates a flow restrictor. Maximum working pressure 10.0 bar. Cold water use only.
Side entry BS1212-4 (2016) compact type float operated valve for WC flushing cisterns. The inlet incorporates a flow restrictor. Maximum working pressure 10.0 bar. Cold water use only.
Side entry BS1212-4 (2016) compact type float operated valve for WC flushing cisterns. The inlet incorporates a flow restrictor. Maximum working pressure 10.0 bar. Cold water use only.
Range of BS1212-4 diaphragm type inlet valves incorporating a plastic body for use in either side or bottom entry WC cisterns. The valves incorporate an up and over discharge, plastic arm and float. The inlet is fitted with a plastic flow regulator and strainer. Maximum working pressure 10 bar. Cold water use only.
Side entry BS1212-4 (2016) compact type float operated valves for WC flushing cisterns. The inlet incorporates a plastic strainer and flow restrictor. Maximum working pressure 10.0 bar. Cold water use only.
Bottom Entry BS1212-4 (2016) compact type float operated valves for WC flushing cisterns. Incorporates plastic body and ½’’ BSP inlet. The inlet incorporates a plastic strainer and flow restrictor. Maximum working pressure 10.0 bar. Cold water use only.
Bottom entry BS1212-4 (2016) compact type float operated inlet valve for WC flushing cisterns with a plastic body and adjustable float and a plastic flow regulator at the inlet. Maximum working pressure 10.0 bar. Cold water use only.
BS1212-4 (2016) compact type float operated valve for WC flushing cisterns, side entry type. The inlet incorporates a plastic flow restrictor. Maximum working pressure 10.0 bar. Cold water use only.
Range of BS1212-4 (2016) compact type float operated valves for WC flushing cisterns, bottom or side entry type. The inlet incorporates a strainer. Maximum working pressure 10.0 bar. Cold water use only.
Side entry BS1212-4 (2016) compact type float operated valves for WC flushing cisterns. The inlet incorporates a plastic strainer and flow restrictor. Maximum working pressure 10.0 bar. Cold water use only.
Range of side entry BS1212-4 (2016) compact type float operated valves for WC flushing cisterns. The inlet incorporates a strainer. Maximum working pressure 10.0 bar. Cold water use only.
Range of bottom or side entry BS1212-4 (2016) compact type float operated inlet valves for WC flushing cisterns incorporating plastic flow regulator at the inlet. Maximum working pressure 10.0 bar. Cold water use only.
Bottom entry BS1212-4 (2016) compact type float operated valve for WC flushing cisterns. The inlet incorporates a flow restrictor. Maximum working pressure 10.0 bar. Cold water only.
Bottom entry BS1212-4 (2016) compact type float operated valve for WC flushing cisterns. The inlet incorporates a flow restrictor. Maximum working pressure 10.0 bar. Cold water only
Side entry BS1212-4 (2016) compact type float operated valve for WC flushing cisterns. The inlet incorporates a flow restrictor. Maximum working pressure 10.0 bar. Cold water use only.
Range of bottom entry BS1212-4 (2016) compact type float operated valve for WC flushing cisterns. The inlet incorporates a plastic strainer. Maximum working pressure 10.0 Bar. Cold water use only.
Side entry BS1212-4 (2016) compact type float operated valves for WC flushing cisterns. The inlet incorporates a strainer. Maximum working pressure 10.0 bar. Cold water use only.
Bottom entry BS1212-4 (2016) compact type float operated valve for WC flushing cisterns. The inlet incorporates a flow restrictor. Maximum working pressure 10.0 bar. Cold water only
Side entry BS1212-4 (2016) compact type float operated valve for WC flushing cisterns. The inlet incorporates a flow restrictor. Maximum working pressure 10.0 bar. Cold water use only.
Side entry BS1212-4 (2016) compact type float operated valve for WC flushing cisterns. Maximum working pressure 10.0 bar. Cold water use only.
Bottom entry BS1212-4 (2016) compact type float operated inlet valve for WC flushing cisterns with a plastic body and adjustable float and a plastic flow regulator at the inlet. Maximum working pressure 10.0 bar. Cold water use only.
Range of side or bottom entry BS1212-4 (2016) compact type float operated valve for WC flushing cisterns. The inlet incorporates a flow regulator. Maximum working pressure 10.0 bar. Cold water use only.
Range of BS1212-4 (2016) float operated valves for WC flushing cisterns, bottom or side entry type with plastic or brass ½’’ BSP inlet. The inlet incorporates a strainer, Compact models incorporate a delay fill function. Maximum working pressure 10.0 bar. For use with cold water only.
BS EN 14055: 2018 WC flushing cistern incorporating a side or bottom compact type float operated inlet valve providing a Type AG air gap with a dual flush drop valve (Phantom T & Phantom V) or dual flush syphon (Phantom S) for full flush volumes of up to 6 litres and a reduced flush of up to 4 litres. The cistern can be operated by lever or manual push button. Maximum working pressure 10.0 bar. Cold water use only.
BS EN 14055: 2018 concealed WC cistern incorporating a side or bottom entry compact type float operated inlet valve providing a Type AG air gap with a pneumatic or cable operated drop valve capable of full flush volumes of up to 6 litres and reduced flush of up to 4 litres. The cistern is operated by a manual push button. Maximum working pressure 10.0 bar. Cold water use only.
Concealed WC dual flushing cistern with a vertical BS 1212-4(2016) float operated inlet valve providing a Type AG air gap arrangement and a dual flush pneumatic outlet valve. The flush volume is operated by a two push button assembly for a 6 or 3 litre flush volume. Maximum working pressure 10.0 bar. Cold water use only.
WC flushing cistern incorporating a side entry compact type float operated inlet valve providing a Type AG air gap with a dual flush drop valve for full flush volumes of up to 6 litres and a reduced flush of up to 4 litres. The cistern is operated by a manual push button and incorporates a servicing valve on the inlet supply. Maximum working pressure 10.0 bar. Cold water use only.
WC flushing cistern incorporating a side entry compact type float operated inlet valve providing a Type AG air gap with a dual flush drop valve for full flush volumes of up to 6 litres and a reduced flush of up to 4 litres. The cistern is operated by a manual push button and incorporates a servicing valve on the inlet supply. Maximum working pressure 10.0 bar. Cold water use only.
WC flushing cistern incorporating a side entry compact type float operated inlet valve providing a Type AG air gap with a dual flush drop valve for full flush volumes of up to 6 litres and a reduced flush of up to 4 litres. The cistern is operated by a manual push button and incorporates a servicing valve on the inlet supply. Maximum working pressure 10.0 bar. Cold water use only.
BS EN 14055 (2018) WC Cistern incorporating a side or bottom entry float operated inlet valve discharging via a Type AG air gap and a dual flush Syphon of full flush volumes of up to 6 litres and a reduced flush of up to 4 litres. The cistern is operated by a lever. Maximum working pressure 10.0 bar. Cold water use only.
BS EN 14055 (2018) concealed WC cistern incorporating a side or bottom entry compact type float operated inlet valve discharging via a type AG airgap and a dual or single flush pneumatic or dual flush cable operated drop valve capable of full flush volumes of up to 6 litres with a reduced flush of up to 4 litres. The cistern is operated by manual push button/push plate. The side entry inlet valve is mounted internally and is supplied via a stainless steel braided EPDM lined flexible hose assembly which incorporates a servicing valve. Maximum working pressure 10.0 bar. Cold water use only.
BS EN 14055 (2018) WC Cistern incorporating a side or bottom entry float operated inlet valve discharging via a Type AG air gap and a dual flush Syphon of full flush volumes of up to 6 litres and a reduced flush of up to 4 litres. The cistern is operated by a lever. Maximum working pressure 10.0 bar. Cold water use only.
Concealed WC dual flushing cistern with a vertical BS 1212-4 (2016) float operated inlet valve providing a Type AG air gap arrangement and a pneumatically operated dual flush outlet valve. The flush volume is operated by a two push button assembly for a 6 or 3 litre flush volume. The inlet supply incorporates a servicing valve. For use with cold water only. Maximum working pressure 10.0 bar.
Concealed WC dual flushing cistern with a vertical BS 1212-4 (2016) float operated inlet valve providing a Type AG air gap arrangement and a pneumatically operated dual flush outlet valve. The flush volume is operated by a two push button assembly for a 6 or 3 litre flush volume. The inlet supply incorporates a servicing valve. Maximum working pressure 10.0 bar. Cold water use only.
Concealed WC dual flushing cistern with a vertical BS 1212-4(2016) float operated inlet valve providing a Type AG air gap arrangement and a dual flush pneumatic outlet valve. The flush volume is operated by a two push button assembly for a 6 or 3 litre flush volume. Maximum working pressure 10 bar. Cold water use only.
WC flushing cistern incorporating a bottom entry BS1212-4 (2016) compact type float operated inlet valve providing a Type AG air gap with a dual flush drop valve for full flush volumes of up to 6 litres and a reduced flush of up to 3 litres. The cistern is operated by a pnuematic push button. Maximum working pressure 10.0 bar. Cold water use only.
Range of concealed WC cistern in white plastic incorporating a BS 1212-4:2016 side entry float operated inlet valve providing a Type AG air gap arrangement and a single or dual flush outlet valve. The full flush can be set at 6 litres and the reduced flush can be set at 3 litres. The inlet supply incorporates a servicing valve. Maximum operating pressure 10.0 bar. Cold water use only.
Range of concealed WC cistern in white plastic incorporating a BS 1212-4:2016 side entry float operated inlet valve providing a Type AG air gap arrangement and a single or dual flush outlet valve. The full flush can be set at 6 litres and the reduced flush can be set at 3 litres. The inlet supply incorporates a servicing valve. Maximum operating pressure 10.0 bar. Cold water use only.
Concealed WC dual flushing cistern with a BS 1212-4 (2016) float operated inlet valve providing a Type AG air gap arrangement and a dual flush pneumatic outlet valve. The cistern incorporates an angled servicing valve and a stainless-steel braided EPDM lined flexible hose assembly installed prior to the inlet valve. The flush volume is operated by a two-push button assembly for a 6 or 3 litre flush volume. Maximum working pressure 10.0 bar. Cold water use only.
AQUAECO RANGE OF WC flushing cistern incorporating a side entry compact type float operated inlet valve providing a Type AG air gap with a dual flush drop valve for full flush volumes of up to 6 litres and a reduced flush of up to 4 litres. The cistern is operated by a manual push button and incorporates a servicing valve on the inlet supply. Maximum working pressure 10.0 bar. Cold water use only.
AQUAECO WC flushing cistern incorporating a side entry compact type float operated inlet valve providing a Type AG air gap with a dual flush drop valve for full flush volumes of up to 6 litres and a reduced flush of up to 4 litres. The cistern is operated by a manual push button and incorporates a servicing valve on the inlet supply. Maximum working pressure 10.0 bar. Cold water use only.
AQUAECO WC flushing cistern incorporating a side entry compact type float operated inlet valve providing a Type AG air gap with a dual flush drop valve for full flush volumes of up to 6 litres and a reduced flush of up to 4 litres. The cistern is operated by a manual push button and incorporates a servicing valve on the inlet supply. Maximum working pressure 10.0 bar. Cold water use only.
WC flushing cistern incorporating a side entry compact type float operated inlet valve providing a Type AG air gap with a dual flush drop valve for full flush volumes of up to 6 litres and a reduced flush of up to 4 litres. There is a flow restrictor and stainless-steel strainer on the inlet valve. The cistern is operated by a manual push button. Maximum operating pressure 8.0 bar. Cold water use only.
WC flushing cistern incorporating a side entry compact type float operated inlet valve providing a Type AG air gap with a dual flush drop valve for full flush volumes of up to 6 litres and a reduced flush of up to 4 litres. The cistern is operated by a manual push button and incorporates a servicing valve on the inlet supply. Maximum working pressure 10.0 bar. Cold water use only.
WC flushing cistern incorporating a side entry compact type float operated inlet valve providing a Type AG air gap with a dual flush drop valve for full flush volumes of up to 6 litres and a reduced flush of up to 4 litres. The cistern is operated by a manual push button and incorporates a servicing valve on the inlet supply. Maximum working pressure 10.0 bar. Cold water use only.
WC flushing cistern incorporating a side entry compact type float operated inlet valve providing a Type AG air gap with a dual flush drop valve for full flush volumes of up to 6 litres and a reduced flush of up to 4 litres. The cistern is operated by a manual push button and incorporates a servicing valve on the inlet supply. Maximum working pressure 10.0 bar. Cold water use only.
Range of WC flushing cisterns incorporating a BS 1212-4 (2016) side entry compact type float operated inlet valve providing a Type AG air gap with a dual flush drop valve for full flush volumes of up to 6 litres and a reduced flush of up to 4 litres or 4.5/3 litre flush volumes. The cistern is operated by a manual push button and the product incorporates a servicing valve on the inlet supply. Maximum working pressure 10.0 bar. Cold water use only.
WC flushing cistern incorporating a side entry compact type float operated inlet valve providing a Type AG air gap with a dual flush drop valve for full flush volumes of up to 6 litres and a reduced flush of up to 4 litres. The cistern is operated by a manual push button and incorporates a servicing valve on the inlet supply. Maximum working pressure 10.0 bar. Cold water use only.
Concealed WC dual flushing cistern with a BS 1212-4 (2016) float operated inlet valve providing a Type AG air gap arrangement and a dual flush pneumatic outlet valve. The flush volume is operated by a two-push button assembly for a 6 or 3 litre flush volume. Maximum working pressure 10.0 bar. Cold water use only.
Range of concealed WC flushing cisterns with a side entry BS 1212-4(2016) float operated inlet valve providing a type AG air gap arrangement and a dual flush outlet valve. The flush volume is operated by a two button assembly for a 6 or 3 litre flush volume. The cistern incorporates a servicing valve and a stainless-steel braided EPDM lined flexible hose assembly installed prior to the inlet valve. Maximum working pressure 10.0 Bar, Cold Water use only
Range of concealed WC flushing cisterns incorporating a side entry compact type float operated inlet valve providing a Type AG air gap with a dual flush drop valve for full flush volumes of up to 6 litres and a reduced flush of up to 4 litres. The cistern is operated by a manual push button and incorporates a servicing valve and flexible hose on the inlet supply. Maximum working pressure 10.0 bar. Cold water use only. .
Concealed WC dual flushing cistern with a BS 1212-4 (2016) float operated inlet valve providing a Type AG air gap arrangement and a dual flush pneumatic outlet valve. The flush volume is operated by a two-push button assembly for a 6 or 3 litre flush volume and incorporates a servicing valve and flexible hose on the inlet supply. Maximum working pressure 10.0 bar. Cold water use only.
Range of concealed WC flushing cisterns incorporating a side entry compact type float operated inlet valve providing a Type AG air gap with a dual flush drop valve for full flush volumes of up to 6 litres and a reduced flush of up to 4 litres. The cistern is operated by a manual push button and incorporates a servicing valve and flexible hose on the inlet supply. Maximum working pressure 10.0 bar. Cold water use only.
Range of concealed WC flushing cisterns incorporating a side entry BS1212-4 (2016) compact type float operated inlet valve providing a Type AG air gap with a dual flush drop valve for full flush volumes of up to 6 litres and a reduced flush of up to 4 litres. The cistern is operated by a manual push button and incorporates a servicing valve and flexible hose on the inlet supply. Maximum working pressure 10.0 bar. Cold water use only.
Range of concealed WC flushing cisterns incorporating a side entry compact type float operated inlet valve providing a Type AG air gap with a dual flush drop valve for full flush volumes of up to 6 litres and a reduced flush of up to 4 litres. The cistern is operated by a manual push button and incorporates a servicing valve and flexible hose on the inlet supply. Maximum working pressure 10.0 bar. Cold water use only.
BS EN 14055 (2018) WC Cistern incorporating a side or bottom entry float operated inlet valve discharging via a Type AG air gap and a lever operated dual flush syphon with full flush volumes of up to 6 litres and a reduced flush of up to 3 litres. Maximum working pressure 10.0 bar. Cold water use only.
WC flushing cistern incorporating a side entry BS1212-4 (2016) compact type float operated inlet valve providing a Type AG air gap with a dual flush drop valve for full flush volumes of up to 6 litres and a reduced flush of up to 3 litres and incorporates a servicing valve and flexible hose on the inlet supply.The cistern is operated by a pnuematic push button Maximum working pressure 10.0 bar. Cold water use only.
Concealed WC dual flushing cistern with a BS 1212-4(2016) float operated inlet valve providing a Type AG air gap arrangement and a dual flush pneumatic outlet valve. The flush valve is operated by a two-push button assembly for a 6 or 3 litre flush volume. Maximum working pressure - 10 Bar, cold water use only.
Range of WC flushing cisterns incorporating a BS 1212-4 (2016) side entry compact type float operated inlet valve providing a Type AG air gap with a dual flush drop valve for full flush volumes of up to 6 litres and a reduced flush of up to 4 litres or 4.5/3 litre flush volumes. The cistern is operated by a manual push button and the product incorporates a servicing valve on the inlet supply. Maximum working pressure 10.0 bar. Cold water use only.
Concealed WC dual flushing cistern with a BS 1212-4 (2016) float operated inlet valve providing a Type AG air gap arrangement and a dual flush pneumatic outlet valve. The flush volume is operated by a two-push button assembly for a 6 or 3 litre flush volume. Maximum working pressure 10.0 bar. Cold water use only.
Concealed WC dual flushing cistern with a BS 1212-4 (2016) float operated inlet valve providing a Type AG air gap arrangement and a dual flush outlet valve. The flush volume is operated by a two push button assembly for a 6 or 3 litre flush volume. Incorporating a servicing valve on the inlet supply. Maximum working pressure 10.0 bar. Cold water use only.
WC flushing cistern incorporating a side entry BS1212-4 (2016) compact type float operated inlet valve providing a Type AG air gap with a dual flush drop valve for full flush volumes of up to 5.5 litres and a reduced flush of up to 2.7 litres and incorporates a servicing valve and flexible hose on the inlet supply. The cistern is operated by a manually operated push button. Maximum working pressure 10.0 bar. Cold water use only.
Concealed WC dual flushing cistern with a BS 1212-4 (2016) float operated inlet valve providing a Type AG air gap arrangement and a dual flush pneumatic outlet valve. The flush volume is operated by a two-push button assembly for a 6 or 3 litre flush volume and incorporates a servicing valve and flexible hose on the inlet supply. Maximum working pressure 10.0 bar. Cold water use only.
Concealed WC dual flushing cistern with a BS 1212-4 (2016) float operated inlet valve providing a Type AG air gap arrangement and a dual flush pneumatic outlet valve. The flush volume is operated by a two-push button assembly for a 6 or 3 litre flush volume and incorporates a servicing valve and flexible hose on the inlet supply. Maximum working pressure 10.0 bar. Cold water use only.
Concealed WC dual flushing cistern with a BS 1212-4 (2016) float operated inlet valve providing a Type AG air gap arrangement and a dual flush pneumatic outlet valve. The flush volume is operated by a two-push button assembly for a 6 or 3 litre flush volume and incorporates a servicing valve and flexible hose on the inlet supply. Maximum working pressure 10.0 bar. Cold water use only.
Concealed WC dual flushing cistern with a BS 1212-4 (2016) float operated inlet valve providing a Type AG air gap arrangement and a dual flush outlet valve. The flush volume is operated by a push button assembly for a 6 or 3 litre flush volume. The inlet supply incorporates a servicing valve and a stainless steel braided PEX lined flexible hose assembly. Maximum working pressure 10.0 bar. Cold water use only.
Range of concealed WC flushing cisterns incorporating a side entry compact type float operated inlet valve providing a Type AG air gap with a dual flush drop valve for full flush volumes of up to 6 litres and a reduced flush of up to 4 litres. The cistern is operated by a manual push button and incorporates a servicing valve and flexible hose on the inlet supply. Maximum working pressure 10.0 bar. Cold water use only. .
Concealed WC dual flushing cistern with a BS 1212-4 (2016) float operated inlet valve providing a Type AG air gap arrangement and a dual flush pneumatic outlet valve. The flush volume is operated by a two-push button assembly for a 6 or 3 litre flush volume. Maximum working pressure 10.0 bar. Cold water use only.
Range of concealed WC flushing cisterns incorporating a side entry compact type float operated inlet valve providing a Type AG air gap with a dual flush drop valve for full flush volumes of up to 6 litres and a reduced flush of up to 4 litres. The cistern is operated by a manual push button and incorporates a servicing valve and flexible hose on the inlet supply. Maximum working pressure 10.0 bar. Cold water use only.
Range of concealed WC flushing cisterns incorporating a BS 1212-4 side entry compact type float operated inlet valve providing a Type AG air gap with a dual flush drop valve for full flush volumes of up to 6 litres and a reduced flush of up to 3 litres. The cistern is operated by a manual push button and incorporates a servicing valve and flexible hose on the inlet supply. Maximum working pressure 10.0 bar. Cold water use only
Range of WC flushing cisterns incorporating a side entry BS 1212-4 (2016) compact type float operated inlet valve providing a Type AG air gap with a dual flush drop valve for full flush volumes of up to 6 litres and a reduced flush of up to 4 litres. The cistern is operated by a manual push button and incorporates a servicing valve and flexible hose on the inlet supply. Maximum working pressure 10.0 bar. Cold water use only.
WC flushing cisterns incorporating a BS 1212-4 side entry compact type float operated inlet valve providing a Type AG air gap with a dual flush drop valve for full flush volumes of up to 6 litres and a reduced flush of up to 4 litres. The cistern is operated by a manual push button and incorporates a servicing valve on the inlet supply. Maximum working pressure 10.0 bar. Cold water use only.
Concealed WC dual flushing cistern with a bottom entry BS 1212-4(2016) float operated inlet valve providing a Type AG air gap arrangement and a dual flush outlet valve for full flush volumes of up to 6 litres and a reduced flush of up to 3 litres. The cistern is operated by a manual push button. Maximum working pressure - 10 Bar Maximum operating temperature – Cold water use only.
Concealed WC dual flushing cistern with a bottom entry BS 1212-4(2016) float operated inlet valve providing a Type AG air gap arrangement and a dual flush outlet valve for full flush volumes of up to 6 litres and a reduced flush of up to 3 litres. The cistern is operated by a manual push button. Maximum working pressure - 10 Bar Maximum operating temperature – Cold water use only.
WC flushing cistern incorporating a side entry BS1212-4 (2016) compact type float operated inlet valve providing a Type AG air gap with a dual flush drop valve for full flush volumes of up to 5.5 litres and a reduced flush of up to 2.7 litres and incorporates a servicing valve and flexible hose on the inlet supply. The cistern is operated by a manually operated push button. Maximum working pressure 10.0 bar. Cold water use only.
Concealed WC dual flushing cistern with a bottom entry BS 1212-4(2016) float operated inlet valve providing a Type AG air gap arrangement and a dual flush outlet valve. The flush volume is operated by a two-push button assembly for a 6 or 3 litre flush volume. Maximum working pressure – 10.0 bar, cold water use only.
Range of concealed WC flushing cisterns incorporating a side entry compact type float operated inlet valve providing a Type AG air gap with a dual flush drop valve for full flush volumes of up to 6 litres and a reduced flush of up to 4 litres. The cistern is operated by a manual push button and incorporates a servicing valve and flexible hose on the inlet supply. Maximum working pressure 10.0 bar. Cold water use only.
Range of concealed WC flushing cisterns incorporating a side entry BS1212-4 (2016) compact type float operated inlet valve providing a Type AG air gap with a dual flush drop valve for full flush volumes of up to 6 litres and a reduced flush of up to 4 litres. The cistern is operated by a manual push button and incorporates a servicing valve and flexible hose on the inlet supply. Maximum working pressure 10.0 bar. Cold water use only.
Concealed WC flushing cisterns incorporating a BS 1212-4 side entry compact type float operated inlet valve providing a Type AG air gap with a dual flush drop valve for full flush volumes of up to 6 litres and a reduced flush of up to 3 litres. The cistern is operated by a manual push button and incorporates a angle valve and flexible hose on the inlet supply. Maximum working pressure 10.0 bar. Cold water use only.
Range of high and low level BS EN 14055 (2018) WC cisterns incorporating a side or bottom entry float operated inlet valve discharging via a Type AG air gap and a dual flush or mono flush syphon for full flush volumes of up to 6 litres and a reduced flush of up to 4 litres.. Maximum working pressure 10.0 bar. Cold water use only.
Concealed WC dual flushing cistern with a bottom entry BS 1212 - 4(2016) float operated inlet valve providing a Type AG air gap arrangement and a dual flush outlet valve. The flush volume is operated by a two-push button assembly for a 6 or 3 litre flush volume. Maximum working pressure 10.0 bar, cold water use only.
WC flushing cistern incorporating a side entry compact type float operated inlet valve providing a Type AG air gap with a dual flush drop valve for full flush volumes of up to 6 litres and a reduced flush of up to 4 litres. The cistern is operated by a manual push button and incorporates a servicing valve on the inlet supply. Maximum working pressure 10.0 bar. Cold water use only.
Concealed WC dual flushing cistern with a side entry BS 1212-4 (2016) float operated inlet valve providing a Type AG air gap arrangement and a dual flush outlet valve. The flush volume is operated by a two-push button assembly for a 6 or 3 litre flush volume. The cistern is operated by a manual push button and incorporates a servicing valve and flexible hose on the inlet supply. Maximum working pressure – 10.0 bar, cold water use only.
Concealed WC dual flushing cistern with a vertical BS 1212-4(2016) float operated inlet valve providing a Type AG air gap arrangement and a dual flush outlet valve. The flush volume is operated by a two push button assembly for a 6 or 3 litre flush volume. Maximum working pressure - 10 Bar Maximum operating temperature – Cold water use only.
Concealed WC flushing cisterns incorporating a side entry compact type float operated inlet valve providing a Type AG air gap with a dual flush drop valve for full flush volumes of up to 6 litres and a reduced flush of up to 3.5 litres. The cistern is operated by an electronically controlled flush valve. The product also incorporates a servicing valve and flexible hose on the inlet supply. Maximum working pressure 10.0 bar. Cold water use only.
Range of concealed WC flushing cisterns incorporating a side entry compact type float operated inlet valve providing a Type AG air gap with a dual flush drop valve for full flush volumes of up to 6 litres and a reduced flush of up to 3.5 litres. The cistern is operated by an electronically controlled flush valve. The product also incorporates a servicing valve and flexible hose on the inlet supply. Maximum working pressure 10.0 bar. Cold water use only.
WC flushing cistern incorporating a side entry BS 1212-4 compact type float operated inlet valve providing a Type AG air gap with a dual flush drop valve for full flush volumes of up to 6 litres and a reduced flush of up to 4 litres. The cistern is operated by a manual push button and incorporates a servicing valve on the inlet supply. Maximum working pressure 10.0 bar. Cold water use only.
Concealed WC dual flushing cistern with a bottom entry BS 1212 - 4(2016) float operated inlet valve providing a Type AG air gap arrangement and a dual flush outlet valve. The flush volume is operated by a two-push button assembly for a 6 or 3 litre flush volume. Maximum working pressure 10.0 bar, cold water use only.
Concealed WC flushing cisterns incorporating a side entry compact type float operated inlet valve providing a Type AG air gap with a dual flush drop valve for full flush volumes of up to 6 litres and a reduced flush of up to 4 litres. The cistern is operated by an electronically controlled flush valve. Maximum working pressure 10.0 bar. Cold water use only
WC flushing cistern incorporating a side entry BS 1212-4 compact type float operated inlet valve providing a Type AG air gap with a dual flush drop valve for full flush volumes of up to 6 litres and a reduced flush of up to 4 litres. The cistern is operated by electronic or manual actuation. Maximum working pressure 10.0 bar. Cold water use only
Range of concealed WC dual flushing cisterns with a vertical BS 1212-4(2016) float operated inlet valve providing a Type AG air gap arrangement and a dual flush outlet valve. The flush volume is operated by a two-push button assembly. The product also incorporates a servicing valve and flexible hose on the inlet supply. Maximum working pressure 10 Bar, cold water use only.
Range of concealed WC dual flushing cisterns with a vertical BS 1212-4(2016) float operated inlet valve providing a Type AG air gap arrangement and a dual flush outlet valve. The flush volume is operated by a two-push button assembly. The product also incorporates a servicing valve and flexible hose on the inlet supply. Maximum working pressure 10 Bar, cold water use only.
WC flushing cistern incorporating a side entry BS 1212-4 (2016) compact type float operated inlet valve providing a Type AG air gap with a dual flush valve for full flush volumes of up to 6 litres and a reduced flush of up to 4 litres. The cistern is operated by a manual push button and incorporates a servicing valve and flexible hose on the inlet supply. Maximum working pressure 10.0 bar. Cold water use only.
Range of concealed WC flushing cisterns incorporating a side entry compact type float operated inlet valve providing a Type AG air gap with a dual flush drop valve for full flush volumes of up to 6 litres and a reduced flush of up to 3.5 litres. The cistern is operated by an electronically controlled flush valve. The product also incorporates a servicing valve and flexible hose on the inlet supply. Maximum working pressure 10.0 bar. Cold water use only.
Range of concealed WC flushing cisterns incorporating a side entry compact type float operated inlet valve providing a Type AG air gap with a dual flush drop valve for full flush volumes of up to 6 litres and a reduced flush of up to 4 litres. The cistern is operated by a manual push button and incorporates a servicing valve and flexible hose on the inlet supply. Maximum working pressure 10.0 bar. Cold water use only. .
Range of concealed WC dual flushing cisterns with a vertical BS 1212-4(2016) float operated inlet valve providing a Type AG air gap arrangement and a dual flush outlet valve. The flush volume is operated by a two-push button assembly. The product also incorporates a servicing valve and flexible hose on the inlet supply. Maximum working pressure 10 Bar, cold water use only.
Range of concealed cisterns incorporating a side entry float operated inlet valve providing a type AC air gap arrangement and a dual flush outlet valve. Maximum working pressure 10.0 Bar. Cold water use only.
BS EN 14055: 2018 concealed WC cistern incorporating a side entry compact type float operated inlet valve providing a type `AB` airgap (verified by test - suitable for backflow protection against fluid category 5) with a pneumatic or cable operated drop valve capable of full flush volumes of up to 6 litres and reduced flush of up to 4 litres. The cistern is operated by manual push button. Maximum working pressure 10.0 bar. Cold water use only.
BS EN 14055 (2018) concealed WC cistern incorporating a side entry compact type float operated inlet valve discharging via a type `AB` airgap (verified by test - suitable for backflow protection against fluid category 5) and a dual or single flush pneumatic or dual flush cable operated drop valve capable of full flush volumes of up to 6 litres with a reduced flush of up to 4 litres. The cistern is operated by manual push button/push plate. One of the side entry inlet valves is mounted internally and is supplied via a stainless steel braided EPDM lined flexible hose assembly which incorporates a servicing valve. Maximum working pressure 10.0 bar. Cold water use only.
BS EN 14055: 2018 concealed WC flushing cistern incorporating a side entry compact type float operated inlet valve providing a Type AB air gap and lever operated syphon capable of full flush volumes of up to 6 litres and reduced flush of up to 4 litres. Maximum working pressure 10.0 bar. Cold water use only.
BS EN 997:2018 Roca Wall Hung W.C. pan (Ceramic), Thomas Dudley ‘A’ frame incorporating a Thomas Dudley Vantage Concealed cistern. The cistern incorporates a side entry compact type float operated inlet valve providing a Type AG air gap with a dual or single flush pneumatic drop valve capable of full flush volumes of up to 6 litres and a reduced flush of up to 4 litres. The cistern can be operated by a manual push button / push plate options. The inlet valve is mounted internally and supplied via a stainless steel braided EPDM lined flexible hose assembly which incorporates a servicing valve. Maximum working pressure 10.0 bar. Cold water use only.
BS EN 997:2018 Vitra wall hung W.C. pan (Ceramic), Thomas Dudley ‘A’ frame incorporating a Thomas Dudley Vantage Concealed cistern. The cistern incorporates a side entry compact type float operated inlet valve providing a Type AG air gap with a dual or single flush pneumatic drop valve capable of full flush volumes of up to 6 litres and a reduced flush of 3 litres. The cistern can be operated by manual a push button / push plate options. The inlet valve is mounted internally and supplied via a stainless steel braided EPDM lined flexible hose assembly which incorporates a servicing valve Maximum working pressure 10.0 bar. Cold water use only.
BS EN 997:2018 Vitra wall hung W.C. pan (Ceramic), Thomas Dudley ‘A’ or Illusion Compact Universal frame incorporating a Thomas Dudley Vantage Concealed cistern. The cistern incorporates a side entry compact type float operated inlet valve providing a Type AG air gap with a dual or single flush pneumatic drop valve capable of full flush volumes of up to 6 litres and a reduced flush of 3 litres. The cistern can be operated by manual a push button / push plate options. The inlet valve is mounted internally and supplied via a stainless steel braided EPDM lined flexible hose assembly which incorporates a servicing valve. Maximum working pressure 10.0 bar. Cold water use only.
BS EN 997:2018 RAK Compact Rimless Wall Hung 700mm COMRIMWH W.C. pan (Ceramic), Thomas Dudley ‘A’ frame incorporating a Thomas Dudley Vantage Concealed cistern with a side entry compact type float operated inlet valve which discharges via a Type AG airgap and a dual flush pneumatic drop valve capable of full flush volumes of 4.5 litres and a reduced flush of 3 litres. The inlet connection hose incorporates a servicing valve. Maximum working pressure 10.0 bar. Cold water use only.
Undercounter boiling water cistern with a stainless steel body, stainless steel element and silicone ‘O’-rings and gaskets. Maximum working pressure 8.0 bar. Maximum operating temperature 95°C.
Undercounter boiling water cistern with a stainless steel body, stainless steel element and silicone ‘O’-rings and gaskets. Maximum working pressure 8.0 bar. Maximum operating temperature 95°C.
`PW` range of one-piece and two-piece GRP water storage cisterns and covers fitted with screened breather and supplied with a screened overflow. Cold water use only.
Purewater ‘PW’ range of GRP sectional storage cisterns and covers fitted with screened breather and supplied with a screened overflow. Cold water use only.
Range of one-piece and two-piece GRP water storage cisterns and covers fitted with screened breather and supplied with a screened overflow. Cold water use only.
Range of one-piece and two-piece GRP water storage cisterns and covers fitted with screened breather and supplied with a screened overflow. Cold water use only.
Range of one-piece and two-piece GRP water storage cisterns and covers fitted with screened breather and supplied with a screened overflow. Cold water use only.
Range of one-piece and two-piece GRP water storage cisterns and covers fitted with screened breather and supplied with a screened overflow. Cold water use only.
DAB range of one-piece and two-piece GRP water storage cisterns and covers fitted with screened breather and supplied with a screened overflow. Cold water use only.
Tanks Direct range of one-piece and two-piece GRP water storage cisterns and covers fitted with screened breather and supplied with a screened overflow. Cold water use only.
‘Precolor’ range of one piece, pre-insulated cold water storage cisterns and covers for domestic water storage, supplied with a wholesome water kit. The cisterns walls are available in grey, blue, green, white, red and anthracite grey (external) colours and the cistern base is straw coloured. For cold water use only. From November 2024 the water contact layer of the cistern base and walls is available in grey or straw colours. The outer layer of the cistern base is available in blue, green, white, red and anthracite grey colours.
Drayton GRP range of one piece, pre-insulated cold water storage cisterns and covers for domestic water storage, supplied with a wholesome water kit. The cisterns walls are available in grey, blue, green, white, red and anthracite grey (external) colours and the cistern base is straw coloured. For cold water use only. From November 2024 the water contact layer of the cistern base and walls is available in grey or straw colours. The outer layer of the cistern base is available in blue, green, white, red and anthracite grey colours.
Flowtech FS Range of GRP sectional storage cisterns and covers fitted with screened breather and supplied with a screened overflow. Cold water use only.
GRPBP range of one piece, pre-insulated cold water storage cisterns and covers for domestic water storage, supplied with a wholesome water kit. The cisterns walls are available in grey, blue, green, white, red and anthracite grey (external) colours and the cistern base is straw coloured. For cold water use only. From November 2024 the water contact layer of the cistern base and walls is available in grey or straw colours. The outer layer of the cistern base is available in blue, green, white, red and anthracite grey colours.
Range of GRP sectional cisterns with butyl seals, stainless steel bolts and an optional PVC-U flange connection. Cold water use only.
Sekisui F range of un-insulated GRP sectional cisterns. The larger cisterns have stainless steel internal bracing and UPVC pole supports. Insulated cisterns were added to the approval in March 2025. All cisterns are for cold water use only.
Press (TH press profile) and screw/compression fittings with brass bodies for use with Comisa Evo Pipe (PE-RT/AL/PE), for above ground use only. Maximum working pressure 10.0 bar. Maximum operating temperature 99°C.
Dudley Quantum single flush push button WC syphon. The syphon is operated via a top mounted cistern push button. For cold water use only.
Dudley Cascade Plus dual flush WC syphon flushing apparatus with a plastic body and stainless-steel link for use with WC flushing cisterns.
Dual flush WC syphon, with a polypropylene body and stainless-steel link for use with WC flushing cisterns. Cold water use only.
Range of combined storage and booster sets, incorporating a cold-water storage cistern, submersible pump, solenoid valve or alternative actuated ball valve, non-return valve (not suitable for backflow protection), isolation valves and expansion vessel. Maximum working pressure 10.0 bar. Cold water use only.
Range of side or bottom entry BS1212-4 (2016) compact type float operated valve for WC flushing cisterns. The inlet incorporates a flow regulator. Maximum working pressure 10.0 bar. Cold water use only.
Range of side or bottom entry BS1212-4 (2016) compact type float operated valve for WC flushing cisterns. The inlet incorporates a flow regulator. Maximum working pressure 10.0 bar. Cold water use only.
Range of bottom and side entry BS1212-4 (2016) compact type float operated valves for WC flushing cisterns, delayed or non-delayed fill. The inlet incorporates a strainer. Maximum working pressure - 10 Bar Cold water use only.
Range of BS1212-4 (2016) compact type float operated valves for WC flushing cisterns, bottom or side entry type with brass ½’’ or ¾” BSP inlet. The inlet incorporates a strainer, models incorporate a delay fill function. The bottom entry valves are height adjustable. Maximum working pressure - 10 Bar, Cold water use only.
Side entry BS1212-4 (2016) compact type float operated valves for use with WC flushing cisterns. The inlet incorporates a strainer. Maximum working pressure 10.0 bar. Cold water use only.
BS1212-4 (2016) compact type float operated valve for WC flushing cisterns, side entry type. The inlet incorporates a plastic flow restrictor. Maximum working pressure 10.0 bar. Cold water use only.
Bottom entry A1370A and side entry A1423B BS1212-4 (2016) compact type float operated valves for WC flushing cisterns. The inlet incorporates a strainer. A1270A - plastic or brass connector. A1423B - plastic connector only. Maximum working pressure 10.0 bar. Cold water use only.
Bottom entry BS1212-4 (2016) compact type float operated valves for use with WC flushing cisterns. The inlet incorporates a strainer. Maximum working pressure 10.0 bar. Cold water use only.
Side and bottom entry BS1212 - 3 compact type float operated valve for WC flushing cisterns Maximum operating pressure 14 bar. Maximum operating temperature 23°C
Bottom entry BS1212-4 (2016) compact type float operated valve for WC flushing cisterns. Maximum working pressure 10.0 bar. Cold water use only. The inlet incorporates a strainer. Maximum working pressure 10.0 bar. For use with cold water only
Range of bottom entry BS1212-4 (2016) compact type float operated valve for WC flushing cisterns. Maximum working pressure 10.0 bar. Cold water use only.
Range of BS1212-4 (2016) compact type float operated valves for WC flushing cisterns, with either bottom entry (A28-06 XXX models) or side entry (A28-06 side). The inlet incorporates a plastic strainer. Maximum working pressure 10.0 Bar Cold Water Use Only
Concealed WC dual flushing cistern with a side entry BS 1212-4 (2016) float operated inlet valve providing a Type AG air gap arrangement and a dual flush outlet valve. The flush volume is operated by a two-push button assembly for a 6 or 3 litre flush volume. The cistern is operated by a manual push button and incorporates a servicing valve and flexible hose on the inlet supply. Maximum working pressure – 10.0 bar, cold water use only.
Range of concealed WC flushing cisterns incorporating a side entry compact type float operated inlet valve providing a Type AG air gap with a dual flush drop valve for full flush volumes of up to 6 litres and a reduced flush of up to 4 litres. The cistern is operated by a manual push button and incorporates a servicing valve and flexible hose on the inlet supply. Maximum working pressure 10.0 bar. Cold water use only.
Range of WC flushing cisterns incorporating a BS 1212-4 (2016) side entry compact type float operated inlet valve providing a Type AG air gap with a dual flush drop valve for full flush volumes of up to 6 litres and a reduced flush of up to 4 litres or 4.5/3 litre flush volumes. The cistern is operated by a manual push button and the product incorporates a servicing valve on the inlet supply. Maximum working pressure 10.0 bar. Cold water use only.
WC flushing cistern incorporating a side entry compact type float operated inlet valve providing a Type AG air gap with a dual flush drop valve for full flush volumes of up to 6 litres and a reduced flush of up to 4 litres. The cistern is operated by a manual push button and incorporates a servicing valve on the inlet supply. Maximum working pressure 10.0 bar. Cold water use only.
Range of wall hung concealed WC flushing cisterns with a BS 1212-4 float operated inlet valve providing a Type AG air gap arrangement and a dual flush outlet valve. The flush volume is operated by a push button assembly. Maximum working pressure - 10 Bar. Cold water use only.
BS EN 14055 (2018) concealed WC cistern incorporating a side or bottom entry compact type float operated inlet valve discharging via a type AG airgap and a dual or single flush pneumatic or dual flush cable operated drop valve capable of full flush volumes of up to 6 litres with a reduced flush of up to 4 litres. The cistern is operated by manual push button/push plate. The side entry inlet valve is mounted internally and is supplied via a stainless steel braided EPDM lined flexible hose assembly which incorporates a servicing valve. Maximum working pressure 10.0 bar. Cold water use only.
Range of wall hung concealed WC flushing cisterns with a BS 1212-4 float operated inlet valve providing a Type AG air gap arrangement and a dual flush outlet valve. The flush volume is operated by a push button assembly. Maximum working pressure - 10 Bar. Cold water use only.
Range of wall hung concealed WC flushing cisterns with a BS 1212-4 float operated inlet valve providing a Type AG air gap arrangement and a dual flush outlet valve. The flush volume is operated by a push button assembly. Maximum working pressure - 10 Bar. Cold water use only.
Range of concealed WC flushing cisterns with a side entry BS 1212-4(2016) float operated inlet valve providing a type AG air gap arrangement and a dual flush outlet valve. The flush volume is operated by a two button assembly for a 6 or 3 litre flush volume. The cistern incorporates a servicing valve and a stainless-steel braided EPDM lined flexible hose assembly installed prior to the inlet valve. Maximum working pressure 10.0 Bar, Cold Water use only
WC flushing cistern incorporating a side entry BS 1212-4 compact type float operated inlet valve providing a Type AG air gap with a dual flush drop valve for full flush volumes of up to 6 litres and a reduced flush of up to 4 litres. The cistern is operated by a manual push button and incorporates a servicing valve on the inlet supply. Maximum working pressure 10.0 bar. Cold water use only.
Range of concealed WC flushing cisterns incorporating a side entry compact type float operated inlet valve providing a Type AG air gap with a dual flush drop valve for full flush volumes of up to 6 litres and a reduced flush of up to 4 litres. The cistern is operated by a manual push button and incorporates a servicing valve and flexible hose on the inlet supply. Maximum working pressure 10.0 bar. Cold water use only.
Range of wall hung concealed WC flushing cisterns with a BS 1212-4 float operated inlet valve providing a Type AG air gap arrangement and a dual flush outlet valve. The flush volume is operated by a push button assembly. Maximum working pressure - 10 Bar. Cold water use only.
Concealed BS EN 14055: 2018 WC flushing cistern incorporating a side or bottom entry compact type float operated inlet valve providing a Type AG air gap with a dual or single flush pneumatic drop valve capable of full flush volumes of up to 6 litres and a reduced flush of up to 4 litres. The cistern can be operated by touch free electronic or manual push button / push plate options. Maximum working pressure 10.0 bar. Cold water use only.
Concealed WC dual flushing cistern with a bottom entry BS 1212 - 4(2016) float operated inlet valve providing a Type AG air gap arrangement and a dual flush outlet valve. The flush volume is operated by a two-push button assembly for a 6 or 3 litre flush volume. Maximum working pressure 10.0 bar, cold water use only.
Range of concealed WC dual flushing cisterns with a vertical BS 1212-4(2016) float operated inlet valve providing a Type AG air gap arrangement and a dual flush outlet valve. The flush volume is operated by a two-push button assembly. The product also incorporates a servicing valve and flexible hose on the inlet supply. Maximum working pressure 10 Bar, cold water use only.
The range of WC cisterns incorporating a BS 1212-4:2016 side entry or bottom entry float operated inlet valve providing a Type AG air gap arrangement and a flush outlet valve operated via a push button assembly for either full or reduced flush. Maximum operating pressure 10.0 bar. Cold water use only.
Concealed BS EN 14055: 2018 WC flushing cistern incorporating a side or bottom compact type float operated inlet valve providing a Type AG air gap with a dual or single flush pneumatic drop valve capable of full flush volumes of up to 6 litres and a reduced flush of 4 litres. The cistern can be operated by touch free electronic or manual push button / push plate options. The supply hose incorporates a servicing valve. Maximum working pressure 10.0 bar. Cold water use only.
Concealed BS EN 14055: 2018 WC flushing cistern incorporating a side or bottom entry compact type float operated inlet valve providing a Type AG air gap with a dual or single flush pneumatic drop valve capable of full flush volumes of up to 6 litres and a reduced flush of up to 4 litres. The cistern can be operated by touch free electronic or manual push button / push plate options. Maximum working pressure 10.0 bar. Cold water use only.
Range of wall hung concealed WC flushing cisterns with a BS 1212-4 float operated inlet valve providing a Type AG air gap arrangement and a dual flush outlet valve. The flush volume is operated by a push button assembly. Maximum working pressure - 10 Bar. Cold water use only.
WC flushing cistern incorporating a side entry compact type float operated inlet valve providing a Type AG air gap with a dual flush drop valve for full flush volumes of up to 6 litres and a reduced flush of up to 4 litres. The cistern is operated by a manual push button and incorporates a servicing valve on the inlet supply. Maximum working pressure 10.0 bar. Cold water use only.
WC flushing cistern incorporating a side entry compact type float operated inlet valve providing a Type AG air gap with a dual flush drop valve for full flush volumes of up to 6 litres and a reduced flush of up to 4 litres. The cistern is operated by a manual push button and incorporates a servicing valve on the inlet supply. Maximum working pressure 10.0 bar. Cold water use only.
WC flushing cistern incorporating a side entry compact type float operated inlet valve providing a Type AG air gap with a dual flush drop valve for full flush volumes of up to 6 litres and a reduced flush of up to 4 litres. The cistern is operated by a manual push button and incorporates a servicing valve on the inlet supply. Maximum working pressure 10.0 bar. Cold water use only.
Concealed WC dual flushing cisterns with a BS 1212- 4 (2016) float operated inlet valve providing a Type AG air gap arrangement and a manually operated dual flush outlet valve. The flush volume is operated by a two-push button assembly for a 6 or 3 litre flush volume. The inlet supply incorporates a servicing valve. Maximum working pressure 10.0 bar. Cold water use only.
WC Cistern incorporating a side or bottom entry float operated inlet valve and a dual flush Drop Valve (Acclaim V) or Syphon (Acclaim S) of full flush volumes of up to 6 litres and a reduced flush of up to 4 litres. The cistern can be operated by lever or manual push button. Maximum working pressure 10.0 bar. Cold water use only.
Concealed BS EN 14055: 2018 WC flushing cistern incorporating a side entry compact type float operated inlet valve providing a type `AB` airgap (verified by test - suitable for backflow protection against fluid category 5) with a dual or single flush pneumatic drop valve capable of full flush volumes of up to 6 litres and a reduced flush of 4 litres. The cistern can be operated by touch free electronic or manual push button / push plate options. The supply hose incorporates a servicing valve. Maximum working pressure 10.0 bar. Cold water use only.
Page of 1
We use cookies to give you the best possible experience with WRAS. Some are essential to provide website functions and ensure the website is secure. We also use cookies to help us understand how people use the site and to make improvements. Click "Accept All" to enable recommended settings or click "Manage cookies" to adjust your settings. For more details, see our Cookie Policy.