Chrome plated plastic shower handset, shower hose. Maximum operating temperature 60°C.
shower handset with various finishes. Model HS149 incorporates a stainless steel strainer washer at the inlet. Maximum operating temperature 65°C.
Wall elbow with brass body (chromium plated) incorporating two check valves cartridges, however the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum operating temperature 60°C.
Range of overhead shower outlets, (chrome plated brass bodies) incorporating flow regulators on the inlets. Model (716000) is wall mounted, all other models are ceiling mounted. Maximum operating temperature 60.0°C
White plastic shower handset. Maximum operating temperature 60°C
Range of shower handsets and overhead showers with (plastic or chrome plated plastic bodies). Open Outlet use only Maximum operating temperature 75.0°C
Range of drain taps with brass or DZR brass body (some models chrome plated) and rising spindle headwork. Maximum working pressure 16.0 bar. Maximum operating temperature 85°C.
Range of stainless-steel braided TPS lined flexible hose assemblies incorporating EPDM or fibre washers. The products can be supplied with a range of end connections and seals. Some models also incorporate integral isolation valves Push-fit fittings for use with: Copper Pipes manufactured in accordance with BS EN 1057 PB pipes manufactured in accordance with BS 7291-2 PEX pipes manufactured in accordance with BS 7291-3 Maximum working pressure 12.0 bar. Maximum operating temperature 65°C.
‘Qualflex Excel’ range of stainless steel over braided, PEX lined flexible hoses, incorporating EPDM or fibre washers. The products can be supplied with a range of end connections and seals. Some models also incorporate integral isolation valves. Push-fit fittings for use for with: Copper Pipes manufactured in accordance with BS EN 1057 Plastic PB pipes manufactured in accordance with BS 7291-2 Plastic PEX pipes manufactured in accordance with BS 7291-3 Maximum working pressure: 6.0 bar. Maximum operating temperature: 65°C.
Inlet hose consisting of a EPDM inner hose layer and corrugated outer cover. The hose is fitted with an integral device consisting of a water sensitive material which expands when in contact with water. Maximum working pressure 10.0 bar. Maximum operating temperature 90°C.
Range of stainless-steel or nylon braided PEX lined hoses, incorporating EPDM O-ring or gaskets. Maximum working pressure 10.0 bar. Maximum operating temperature 85°C.
Range of stainless steel braided TPSiV lined flexible hose assemblies incorporating EPDM O-rings. Maximum working pressure 10.0 bar. Maximum operating temperature 85°C
Range of stainless-steel braided EPDM lined flexible hose assemblies with EPDM seals, available with a variety of end connections, some of which include isolation valves (see model). Maximum working pressure 10 Bar. Maximum operating temperature 85°C
Range of stainless steel or nylon braided EPDM lined flexible hose assemblies with various brass end connections. Compression connection to be used with copper pipe EN1057. Maximum working pressure 10 Bar. Maximum operating temperature 70°C.
Nylon and stainless-steel braided EPDM lined flexible hose assemblies. Maximum working pressure 10.0 bar. Maximum operating temperature 85°C
Range of automatic air venting valves with plastic bodies and EPDM ‘O’-rings. Maximum working pressure 6.0 bar. Maximum operating temperature 99°C.
Range of wall mounted, concealed, manual blending shower valves with brass bodies (various finishes), incorporating a ceramic cartridge headwork and various single lever operating members. The product is also supplied with ¾” BSP (M) x ½” BSP (F) adaptors. Maximum working pressure 10.0 Bar Maximum operating temperature 70.0°C
Range of wall mounted, concealed, thermostatic shower blending valves (brass bodies – various finishes), The flow is controlled via a 2 way manually operated diverter to the shower outlets. Temperature is controlled via a thermostatic cartridge incorporating a manual override button. The trim sets are provided with dome type operating members. The inlets incorporate an approved single check valve cartridge, however, the complete product has not been fully tested to demonstrate it provides backflow protection. The product is supplied with a shower hose and handset. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.
Wall mounted, concealed, thermostatic blending valve (brass body) with a chromium plated trim set incorporating a single sequential headwork controlling flow and temperature with a single lever operating member. The product also incorporates approved check valve cartridges, however, the complete product has not been fully tested to demonstrate they provide backflow protection. The product is supplied with a combined strainer/isolation valve for each inlet. To be used with copper pipe manufactured to EN 1057. Maximum working pressure; 10 bar. Maximum operating temperature 65°C.
Range of T-type thermostatic mixing valves with DZR brass bodies. Temperature is pre-set under a fixed cap. The inlet adaptors incorporate single check valve cartridges (verified by test, suitable for backflow protection against Fluid Category 2) and stainless-steel strainers. The inlet adaptors for models 400MX15CP & 400MX22CP are 90° elbows instead of straight adaptors and incorporate additional integral spherical valves. Maximum working pressure 10.0 Bar. Maximum operating temperature 85.0°C.
Range of wall mounted, thermostatic blending valves, (brass bodies various finishes), incorporating a quarter turn ceramic disc headwork controlling the flow. Temperature is controlled independently via a thermostatic cartridge with a manual override button incorporating dome or lever type operating members, each inlet incorporates a stainless-steel strainer and an approved check valve cartridge; however, the complete product has not been fully tested to demonstrate it provides backflow protection. The product is supplied with shower handset, hose and riser rail. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.
Range of T-type thermostatic blending valves with DZR brass bodies (various finishes). Compression inlets incorporate a stainless-steel strainer and check valve cartridge, verified by test (suitable for backflow protection against Fluid Category 2). Push-fit inlets incorporate a check valve cartridge, however the complete product has not been fully tested to demonstrate it provides backflow protection. HEAT112050 & HEAT112055 models incorporate angled inlets with integral spherical valves. HEAT112010, HEAT112015, HEAT112050, HEAT112055 – Compression for use with copper pipe (to BSEN1057:2006) only. HEAT155001, HEAT155010 – Push fit for use with PEX pipe (to BS7291 part 3), Polybutylene pipe (to BS7291 part 2) & Copper pipe (to BSEN1057:2006). Maximum working pressure 10.0 bar at 20°C and 7.0 bar at 85°C.
Range of wall mounted shower sets comprising of a concealed, shower valve (brass body – various finishes), overhead shower outlet, shower handset, shower hose and wall elbow. The inlets of both the overhead shower outlet and shower handset incorporate a plastic flow regulator. The flow is controlled to separate shower outlets via a manual diverter. Maximum working pressure 3.5 bar. Maximum operating temperature 60°C.
Range of wall mounted thermostatic bar shower mixers with brass bodies, incorporating a thermostatic cartridge controlling the temperature and non-rising spindle headwork controlling the flow. The inlets incorporate stainless steel strainers and an approved check valve cartridge; however, the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum working pressure 5.0 bar. Maximum operating temperature 85°C.
Fire hydrant (screw down pattern type) with ductile iron body (blue epoxy coated). Maximum working pressure 16.0 bar. For above and below ground, cold-water use.
Fire hydrant with a ductile iron body (blue epoxy powder coated) operated via a non-rising spindle headwork. Maximum working pressure 16.0 bar. Maximum operating temperature 85°C.
Range of angled pressure relief valves (pre-set at various pressures) with DZR brass bodies and EPDM diaphragms. Maximum working pressure: SEE MODELS Maximum operating temperature 99.0°C
Range of latching or non-latching normally closed solenoid valves with brass bodies. Maximum working pressure 10.0 Bar to 15.0 Bar (see models). Maximum operating temperature 90.0°C.
Range of spherical valves incorporating nickel plated brass bodies with chrome plated brass ball and operated via lever, butterfly type handle or screwdriver slot. For use with copper pipe (manufactured to EN1057). Maximum working pressure 16.0 bar. Maximum operating temperature 85°C.
Range of quarter turn, lever handle or butterfly operated spherical valves with nickel plated brass bodies, chrome plated brass balls and PTFE seals. For use with copper pipe BS EN 1057. Maximum working pressure 25.0 bar. Maximum operating temperature 85°C.
Range of spherical isolation valves incorporating brass bodies (nickel plated), brass ball (chrome plated), brass stem and EPDM ‘O’-rings (screwdriver operated or T-type handle). For use with copper pipe (EN1057). Maximum working pressure 16.0 bar (model 10130420) Maximum working pressure 25.0 bar (model 10130379) Maximum working pressure 40.0 bar (models 10130277 & 10130345) Maximum operating temperature 85°C.
Range of spherical valves incorporating either brass (870228 &961665) or nickel plated (961159, 961708, 837973, 845188 & 845187) brass bodies with chrome plated brass ball and operated via lever, butterfly type handle or screwdriver slot. For use with copper pipe (manufactured to EN1057). Maximum working pressure 16.0 bar. Maximum operating temperature 85°C.
Range of spherical valves with DZR brass bodies, chrome plated balls, PTFE seats and FKM O-rings. Maximum working pressure 30.0 bar. Maximum operating temperature 85°C.
Range of spherical valves (brass or chrome plated brass bodies), incorporating chrome plated brass ball and either a single lever or T type operating member. Maximum working pressure 25.0 or 50.0 Bar (see models) Maximum operating temperature 20.0°C
Range of in-line screwdriver operated spherical valves, with brushed chrome brass bodies and chrome plated brass ball. Maximum working pressure 16.0 Bar. Maximum operating temperature 99.0°C.
Range of lever or butterfly operated spherical valves with brushed chromium plated brass bodies, chromium plated brass ball and PTFE seat. Maximum working pressure; Art. 1700, 1710, 1722, 1711 & 6523 models: ¼” to ½” = 64.0 bar, ¾” to 1¼” = 50.0 bar, 1½” to 2” = 40.0 bar, 2½” to 4” = 25.0 bar. Art. 1720 & 1721 models: ¼” to ½” = 64.0 bar, ¾” to 1” = 50.0 bar. Art. 6523 model: ¼” to ⅜” = 64.0 bar, ¾” to 1¼” = 50.0 bar, 1½” to 2” = 40.0 bar, 2½” to 4” = 25.0 bar. Art. 6348, 6354 & 6366 models: ¼” to ⅜” = 64.0 bar. Maximum operating temperature 99°C.
Range of brass stopcocks. Compression connections, to be used with copper pipe EN1057 only. Maximum working pressure 16.0 bar.
Non-metallic materials and components comply with BS6920 at 85°C
‘BOSS VENTURI’ range of regulating valves with DZR brass bodies, PTFE seats, EPDM ‘O’-rings and washer. The product incorporates two test ports. Maximum working pressure 25.0 bar. Maximum operating temperature 85°C.
Range of balancing valves with DZR brass bodies with two test ports, incorporating a non-rising spindle headwork. Maximum working pressure 20.0 bar. Maximum operating temperature 85°C.
Range of modular silver and copper disinfection ion generators with a stainless-steel bodies Maximum working pressure 9.0 bar. Cold water use only.
'61300 EPOXY TB BT BLEU 5005'. Factory applied, blue coloured epoxy powder coating. Spray apply as per manufacturers TDS dated '15/2/2019'. Cure for 20 minutes@160°C. For use with water up to 23°C. This material is only approved for the curing conditions that appear on the approval. If the cure conditions are varied from those specified on the approval then the material is not covered by the scope of the approval.
'Sikagard® 1816 (formerly known MasterProtect® 1816)'. Site applied, grey coloured (once applied), two-component Epoxy polysulfide coating. Mix parts A & B in a 78:22 weight ratio and apply coat 1 as per manufacturer’s general method statement ‘MS - AD - Sikagard®-1816-01/2024’ and PDS '020303000000002044 Version 01.01', dated April 2024. Cure coat 1 for 9 hours@25°C. Mix parts A & B in a 78:22 weight ratio and apply coat 2 as per manufacturer’s general method statement ‘MS - AD - Sikagard®-1816-01/2024’ and PDS '020303000000002044 Version 01.01', dated April 2024. Cure coat 2 for 14 days@25°C. For use with water up to 23°C. This material is only approved for the mixing & curing conditions that appear on the approval. If the mix and/or cure conditions are varied from those specified on the approval then the material is not covered by the scope of the approval.
'GY-PEX-b(60-95)'. White coloured (translucent), extruded PEX hose. For use with water up to 85°C.
'Amodel DW-1140 BK 938 & Amodel DW-1150 BK 938'. Black coloured, injection moulded PPA materials. For use with water up to 85°C.
'VULCAN VEE4 Bellow & Boot'. Black coloured, compression moulded EPDM bellows and boot components. Shore hardness 70. The bellows has an in-radius size of 3.0mm and the boot has an in-radius size of 0.9mm. For use with water up to 85°C.
‘ML57308’ Black coloured, compression moulded EPDM rubber material. Shore hardness 75A. Tested in-radius size 1.0mm. Between April 2025 and April 2025, the material is for use with water up to 23°C. Between May 2025 and April 2029, the material is for use with water up to 60°C.
'RBL-9200-20, RBL-9200-30, RBL-9200-40, RBL-9200-50, RBL-9200-60, RBL-9200-65 & RBL-9200-70'. Transparent, colourless injection moulded silicone rubber materials. Shore hardness between 20 & 70. Tested in-radii size between 0.75mm & 2.89mm. For use with water up to 85°C.
‘THERMOLAST DW Compound series (DW/CS2)’. Natural (appears white), injection moulded TPE-S materials. The materials can be coloured and include the following grades: DW(1)OCX-(2): (1) – for "0" to "8" indicating hardness: DW5OCX-(2) (55 ShA). DW6OCX-(2) (65 ShA). DW7OCX-(2) (75 ShA). DW8OCX-(2) (85 ShA). DW0OCX-(2) (35 ShD). (2) - Extension of 4 digits indicating colour. The four digits stands for this: LCNT -> natural material without colour. All other numbers depends on colour. The first digit of the 4 digit colour code indicates the ground colour: 1 = yellow, 2 = orange, 3 = red, 4 = violet, 5 = blue, 6 = green, 7 = grey, 8 = brown & 9 = white or black. The other digits of the 4 digit colour code, indicates the particular shade. For use with water up to 85°C.
‘Wall mounted, electronically operated tap assemblies (brass bodies - in various finishes). The flow is controlled by a solenoid valve that is actuated via an infra-red sensor on the spout. The spout outlet incorporates plastic aerators. Maximum working pressure 6 bar. Maximum operating temperature 65°C.
Range of wall mounted, single hole, single outlet (fixed) electronically controlled tap assemblies (chrome plated brass bodies). Flow is controlled by a solenoid valve that is activated via an infrared sensor. The spout outlet incorporates an aerator. Maximum working pressure: 8.0 Bar. Maximum operating temperature 65°C.
Page 52 of 89
We use cookies to give you the best possible experience with WRAS. Some are essential to provide website functions and ensure the website is secure. We also use cookies to help us understand how people use the site and to make improvements. Click "Accept All" to enable recommended settings or click "Manage cookies" to adjust your settings. For more details, see our Cookie Policy.