Two-hole, single outlet (fixed) combination tap assembly (chromium plated brass). The flow is controlled via non-rising spindle headworks with cross top operating members and a manually operated diverter to shower outlet. Supplied with hose and handset. The spout outlet incorporates a plastic flow straightener. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.
Two hole, single outlet (fixed) combination tap assembly (chromium plated brass) incorporating quarter turn ceramic disc headwork, single lever operating members and self- cancelling diverter to shower outlet. The spout outlet incorporates a plastic flow straightener & the products are supplied with metal backnuts. The product includes a shower hose and handset. Maximum working pressure 10.0 bar. Maximum working temperature 70°C.
Range of wall mounted, two-hole, single outlet (swivel) combination tap assemblies (chromium plated brass), incorporating ceramic cartridge headworks and single lever operating members. The spout outlet incorporates a plastic flow straightener. The inlet offset unions incorporate an isolation valve. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.
Three hole, single outlet (fixed) combination tap assemblies (various finishes), incorporating quarter turn ceramic disc headworks with single lever operating members. The spout outlets incorporate a plastic aerator and is connected to the headworks via stainless steel braided PEX lined hose assemblies. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.
Three hole, single outlet (fixed) combination tap assemblies with a brass body (various finishes), incorporating quarter turn ceramic disc headworks with single lever operating members and a self-cancelling diverter to shower outlet. The spout outlet incorporates a plastic flow aerator. Maximum working pressure 10.0 Bar. Maximum operating temperature 60ºC.
Range of four-hole, single outlet (fixed) combination tap assemblies (various finishes), incorporating quarter turn ceramic disc headworks with single lever or cross top operating members and a self-cancelling diverter to shower outlet. The spout outlets incorporate a plastic aerator. The products are supplied with a shower hose and the hose connector incorporates approved check valve cartridge however, the complete product has not been fully tested to demonstrate it provides backflow protection. Not supplied with a shower handset. Maximum working pressure 5.0 bar Maximum operating temperature 60°C
Range of free-standing sanitary macerating disposal units. The units are fed via a flexible hose assembly. Flow is controlled by a solenoid valve and discharges via a type `AA` air gap. Maximum working pressure 10.0 bar. Cold water use only.
Range of chemical dosing equipment which incorporate self-closing valves with a plastic body. The outlet of the injector incorporates a connection for injection of chemicals via venturi action. Maximum working pressure 9.0 bar. Maximum operating temperature – 60ºC
Filling loop assembly, consisting of a stainless steel braided EPDM lined flexible hose, a lever operated brass spherical valve and a DZR brass double check valve assembly that incorporates a lever operated spherical valve. Maximum working pressure 10.0 bar. Maximum operating temperature 23°C.
Range of Aquaterra PP-RCT socket fusion fittings for use with Aquaterra PP-RCT SDR 6 pipe and Aquaterra PP-RCT SDR 7.4 pipe (manufactured to EN ISO 15874). Maximum working pressure 10.0 bar. Maximum working temperature 85°C.
Viega ‘Raxofix’ press connection fittings for use with viega Raxofix PE-Xc/Al/PE-Xc pipes. For above ground use only. Maximum working pressure 10 bar. Maximum operating temperature 70°C
Viega ‘Raxofix’ press connection fittings for use with viega Raxofix PE-RT/Al/PE-RT pipes. For above ground use only. Maximum working pressure 10.0 bar. Maximum operating temperature 70°C
FloFit range of push fit fittings (polybutylene body) for use with Qual-Pex Barrier Pipe, Qual-PB polybutylene barrier pipe or copper tube. Above ground use only. Maximum working pressure 10.0 bar. Maximum operating temperature 95°C.
‘Maincor’ range of pipe adaptors and ‘Multi-Fit’ straight connectors (brass bodies) for use with ‘Maincor PERT/Al/PERT MLC’ pipe. 12mm pipe and fittings have a maximum working pressure of 6.0 bar. 16mm & 20mm pipe and fittings have a maximum working pressure of 10.0 bar Maximum operating temperature 95°C
‘Numepress’ range of stainless-steel crimp fittings incorporating EPDM and ‘O’-rings. For use with stainless steel tube. Maximum working pressure 16.0 bar. Maximum operating temperature 95°C.
Range of copper solder ring fittings for use with copper tube. For above ground use only. Maximum working pressure 25.0 bar. Maximum operating temperature 99°C.
Range of copper end feed fittings for use with copper tube. For above and below ground use. Maximum working pressure 25.0 bar. Maximum operating temperature 99°C.
Dual flush, WC outlet valves. Model A2706 is operated via a push button assembly for either full or reduced flush. Models A2415L & A2415M are not supplied with a operating button. Maximum operating temperature. Cold water use only.
Range of waste water heat recovery systems incorporating a twin wall copper coil (iZi models) or stainless steel (PiPe models). Maximum working pressure 10.0 bar. Cold water use only.
Range of indirect heat interface units with copper brazed stainless-steel heat exchangers, providing heating and instantaneous hot water. The products incorporate an expansion vessel on the cold-water supply to the plate heat exchanger and a safety relief valve on the space heating circuit set @ 3.0 bar. The domestic hot water and space heating circuit are both fitted with drain valves incorporating cover caps. Maximum working pressures: Domestic hot water 10.0 bar. Space Heating 2.5 bar. District Heating 3.0 bar. Maximum operating temperature 85˚C.
Range of gas fired water heaters incorporating stainless steel strainers on the inlets. Maximum working pressure 10.0 Bar Maximum working temperature 85˚C
Range of wall mounted combination boilers providing domestic hot water via a plate heat exchanger and pressurised central heating system, incorporating a pressure relief valve set at 3.0 bar and expansion vessel on the primary circuit. The inlet of the replenishing valve between the primary and secondary circuits incorporate a plastic strainer. Maximum working pressure 2.5 bar (primary) and 6.0 bar (secondary). Maximum operating temperature 85˚C.
Range of flow sensors with brass bodies. Maximum working pressure 16.0 bar. Maximum operating temperature 90°C
Range of isolation valves incorporating brass bodies and EPDM ‘O’-rings. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.
Range of submersible pumps with stainless steel bodies, impellers and shaft. The XPW range incorporates a strainer cowl on the suction end of the pump. The XPWA range features a stainless head which provides a threaded connection instead of the strainer. Cold water use only.
Range of inline circulating pumps with bronze bodies, plastic impeller and EPDM rubber seals. Maximum working pressure 10.0 bar. Maximum operating temperature 100°C.
Dutypoint ‘VS’ range of cold water supply booster sets, incorporating 2 to 8 pumps with a modular stainless steel manifold system. The booster sets also incorporate spherical valves, non-return valves, pressure switches/sensors and expansion vessels.. Maximum working pressure 10.0 bar. Cold water use only.
Range of positive displacement diaphragm pumps with plastic bodies, EPDM ‘O’-rings and TPE diaphragm. The product incorporates an integral bypass relief valve. For use with John Guest LLDPE Pipe. Maximum working pressure 11.03 Bar (Bypass) and 7.0 Bar (Operating).
Range of shower handsets and shower heads chrome plated plastic bodies and built in combined flow restrictors/approved check valve cartridge however, the complete product has not been fully tested to demonstrate it provides backflow protection. Models added March 2023 are available in various finishes, see model.
Non-metallic materials and components comply with BS6920 at 60°C
Range of shower handsets and shower heads with chromium plated ABS bodies (models A111101 & A121510WT is not chromium plated). Maximum operating temperature 75°C.
Range of overhead shower outlets with chromium plated plastic bodies. Models SD1062 and SD1064 incorporate stainless steel strainers in the inlets. Maximum working temperature 75°C.
A self-closing shower handset with a plastic body, the inlet incorporates a plastic flow restrictor and an approved check valve cartridge, however, the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum working pressure 6.0 bar. Maximum operating temperature 85 °C.
Range of shower handsets with chromium plated plastic bodies. Maximum operating temperature 75°C.
Shower handset incorporating a chromium plated plastic body. Maximum operating temperature 65°C.
Shower handset (various finishes) with built in flow restrictor. Maximum operating temperature 60°C.
Shower hose incorporating an EPDM liner and grey PET outer layer. Supplied with EPDM washers. Maximum operating temperature 70°C.
Range of shower handsets with a chrome plated body. Maximum operating temperature 60°C.

PVC lined, chrome plated shower hose. Maximum operating temperature 60°C.
Range of shower outlets with chromium plated bodies. Models P60901 and P61400 have check valves fitted at the inlets however, the complete products have not been fully tested to demonstrate they provide backflow prevention. Maximum operating temperature 70°C. Open outlet use only.
Wall mounted shower intake, having a brass body (chrome plated). The outlet incorporates a single check valve cartridge (however the complete assembly has not been tested to demonstrate it provides adequate backflow protection) Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.
Range of shower outlets incorporating brass bodies (various finishes). Maximum operating temperature 60°C.
In-line, Y-patterned strainer with stainless steel body and EPDM ‘O’-ring. Maximum working pressure 16.0 bar. Maximum operating temperature 100°C.
Range of in-line “Y” patterned strainers with brass bodies incoroporating NBR ‘O’-rings and stainless steel filters. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.
Range of pillar taps (chrome plated brass) with non-rising spindle headworks and cross type operating members. The spout outlets incorporate a plastic flow straightener and the products are supplied with metal backnuts. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.
Range of pillar taps (chrome plated brass) incorporating non-rising spindle headwork with cross type operating members. The spout outlet incorporates a plastic flow straightener. The product is supplied with metal backnuts. Maximum working pressure 7.0 bar. Maximum operating temperature 60°C.
Range of stainless steel braided EPDM lined hose assemblies with EPDM O-rings and some models incorporate a servicing valve. Maximum working pressure 6.0 bar. Maximum operating temperature 65°C.
Range of stainless steel or ACB braided, PE-RT lined flexible hose assemblies, incorporating various end connections. The 15mm & 22mm compression models may incorporate an isolation valve. The 15mm pushfit incorporates an isolation valve. Models added April 2022 have a maximum operating pressure of 6.0 bar, a maximum operating temperature of 65°C and are for use with copper pipe manufactured to BS EN 1057. All other models have a maximum operating pressure of 10.0 bar and a maximum operating temperature of 85°C
Range of vertical cased and insulated direct and indirect unvented stainless steel hot water storage cylinders. The storage cylinders incorporate an internal air bubble to accommodate the expansion of hot water. The DHW circuit has a factory fitted temperature and pressure relief valve set at 10.0@90˚C. The inlet control group includes a pressure reducing valve set at 3.0 bar, single check valve cartridge (verified by test and suitable for backflow protection against Fluid Category 2) and a expansion valve set at 8.0 bar. The products are supplied with a tundish and a motorised valve to be installed on the primary indirect circuit. Maximum supply pressure to the pressure reducing valve is 12.0 bar. Maximum working pressure of primary circuit is 6.0 bar. Maximum secondary circuit is 9.5 bar. Maximum operating temperature 85°C.
Range of wall mounted, flow control valves with brass bodies and various trim sets (various finishes). Flow is controlled to the outlets via a push to on push to off ‘detent’ headwork. Maximum Working Pressure 10.0 bar. Maximum operating temperature 70°C.
Wall mounted concealed thermostatic shower valve, with a single sequential headwork controlling both flow and temperature. A manual diverter controls the flow between a shower handset or overhead shower. The inlets incorporate a single check valve however the complete assembly has not been tested to demonstrate it provides adequate backflow protection. Maximum working pressure 5.0 bar. Maximum operating temperature 50°C.
Page 6 of 231
We use cookies to give you the best possible experience with WRAS. Some are essential to provide website functions and ensure the website is secure. We also use cookies to help us understand how people use the site and to make improvements. Click "Accept All" to enable recommended settings or click "Manage cookies" to adjust your settings. For more details, see our Cookie Policy.