Range of single hole, single outlet (swivel) combination tap assemblies with brass bodies (various finishes), incorporating a ceramic cartridge headwork with a single lever operating member. This product also incorporates an additional spring-loaded quarter turn ceramic disc headwork with a single lever operating member for filtered cold water discharged from the spout outlet. The spout outlet incorporates a plastic aerator. Maximum working pressure 5.0 bar. Maximum operating temperature 65°C.
Range of single hole, single outlet (swivel) combination tap assemblies with brass bodies (various finishes - see model), incorporating a ceramic cartridge headwork with a single lever operating member. The product also incorporates a separate ¼ turn ceramic disc headwork which supplies a stainless steel braided PEX lined flexible outlet hose assembly incorporating a ½” BSP (M) end connection. This outlet hose is supplied with an optional fibre gasket and ½” BSP (F) x ¾” BSP (M) brass adaptor and is intended to supply an appliance, with the quarter turn ceramic disc headwork acting as a shut-off valve. The spout outlet incorporates a plastic aerator. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.
Range of single hole, single outlet (swivel) combination tap assemblies (chromium plated brass), incorporating a ceramic cartridge headwork with a single lever operating member. The spout outlet incorporates a plastic aerator. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C
Single hole, double outlet combination tap assembly incorporating (chromium plated) brass body and ceramic disc headwork with single lever operating members. Maximum working pressure 6.0 bar. Maximum operating temperature 85°C. The products are supplied with pop up waste which has not been tested.
Range of two-hole, single outlet (fixed) combination tap assemblies (chromium plated brass) incorporating quarter turn ceramic disc headwork with single lever or dome type operating members. The spout outlet of model 60828-5301 incorporates a plastic flow straightener. The spout outlet of models 62277-5001 & 62277-5101 incorporates a plastic aerator. Model 62277-5101 is supplied with metal backnuts. Models 60828-5301 & 62277-5001 are supplied with plastic backnuts. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C
Two-hole, single outlet, fixed combination tap assembly (chrome plated brass) incorporating quarter turn ceramic disc headworks with single lever operating members. The spout outlet incorporate a plastic flow straightener. The product is supplied with metal backnuts. Maximum working pressure 10.0 bar. Maximum operating temperature 65°C.
Two hole, single outlet (fixed) combination tap assembly (chromium plated brass), incorporating quarter turn ceramic disk headworks with single lever operating members. The spout outlet incorporates a combined EPDM washer with a stainless steel strainer and a plastic flow straightener. The product is supplied with metal backnuts. Maximum working pressure 10.0 bar. Maximum operating temperature 65°C.
Range of wall mounted thermostatic mixing valves (chrome plated brass bodies), incorporating ceramic disc diverter headworks controlling the flow from spout outlet to shower outlet using either dome or single lever operating members. The temperature is controlled independently via a thermostatic cartridge incorporating a manual override button either dome or single lever operating members. The spout outlet incorporates a flow straightener or aerator. The inlets incorporate stainless steel strainers and approved single check valve cartridges; however, the complete product has not been fully tested to demonstrate it provides backflow protection. Not supplied with hose and handset. Maximum working pressure 10.0 bar Maximum operating temperature 60°C
Range of floor and wall mounted two-hole, single outlet fixed combination taps assemblies (various finishes) incorporating quarter turn ceramic disc headworks and manual diverter to shower outlet with either single lever operating members on model 16 553 XX0 or cross top on models 16 540 XX0/16 547 XX0. The shower outlet incorporates an approved check valve cartridge, however, the complete product has not been fully tested to demonstrate it provides backflow protection. The spout outlets incorporate plastic aerators and the products are supplied with a shower hose and handset. Maximum working pressure 10.0 bar. Maximum operating temperature 70°C.
Two hole, metal, single outlet (fixed) combination tap assemblies (chromium plated brass) incorporating quarter turn ceramic disc headworks with single lever operating members and a manual diverter to the shower outlet. The spout outlet incorporates a plastic flow straightener. The product is supplied with a shower hose, handset and metal backnuts. Maximum working pressure 10.0 bar. Maximum operating temperature 65°C.
Wall mounted, two-hole, bar type thermostatic blending valve (various finishes, see model) incorporating a half turn ceramic disc for diverting flow between bath/off/shower positions and a thermostatic cartridge controlling the temperature independently, both with dome type operating members. The product also incorporates a self-cancelling diverter to a shower handset. The product is supplied with an overhead shower outlet , shower hose and handset. The spout outlet incorporates a plastic aerator. Each inlet Incorporates approved check valve cartridges; however, the complete product has not been fully tested to demonstrate it provides backflow protection and stainless-steel strainers. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.
Range of two hole, single outlet (swivel) combination tap assembly with brass bodies (chrome plated), incorporating quarter turn ceramic disc headworks and single lever operating members (model 740910) or non-rising spindle headworks with dome type operating member (model 546840). The spout outlet incorporates a plastic aerator or plastic flow straightener. The product is supplied with metal backnuts. Maximum working pressure 10.0 bar. Maximum operating temperature 65°C.
Two hole, single outlet (swivel) combination tap assembly (brass body - various finishes, see model), incorporating a ceramic cartridge headwork with a single lever operating member. The spout is supplied with a stainless steel braided PEX lined flexible hose assembly and a brass connecting nipple for installation onto a quick connect polyamide braided PE lined flexible hose assembly from the headwork. The quick connect hose incorporates an approved check valve cartridge, however, the complete product has not been fully tested to demonstrate it provides backflow protection The spout outlet incorporates a plastic aerator. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.
Range of two hole, single outlet (swivel) combination tap assembly with brass bodies (chrome plated), incorporating quarter turn ceramic disc headworks and single lever operating members (model 1607023) or non-rising spindle headworks with dome type operating member (model 167021). The spout outlet incorporates a plastic aerator or plastic flow straightener. The product is supplied with metal backnuts. Maximum working pressure 10.0 bar. Maximum operating temperature 65°C.
Wall mounted spout outlet (chromium plated brass) incorporating a plastic aerator. Maximum operating temperature 60°C, open outlet use only.
Range of brass spout outlets with various finishes (see model). The products incorporate plastic flow straighteners. Maximum operating temperature 60.0°C
Range of expansion vessels with butyl membranes. Maximum working pressure 8.0, 10.0, 16.0 or 20.0 bar (please refer to model). Maximum operating temperature 70 or 100°C (please refer to model).
Range of expansion vessels with butyl membranes. Maximum working pressure 8.0, 10.0, 16.0 or 20.0 bar (please refer to model). Maximum operating temperature 70 or 100°C (please refer to model).
Range of expansion vessels with butyl membranes. Maximum working pressure 8.0, 10.0, 16.0 or 20.0 bar (please refer to model). Maximum operating temperature 70 or 100°C (please refer to model).
Range of expansion vessels with butyl membranes. Maximum working pressure 8.0, 10.0, 16.0 or 20.0 bar (please refer to model). Maximum operating temperature 70 or 100°C (please refer to model).
Range of expansion vessels with butyl membranes. Maximum working pressure 8.0, 10.0, 16.0 or 20.0 bar (please refer to model). Maximum operating temperature 70 or 100°C (please refer to model).
In-line carbon block water filter with polypropylene body. Maximum working pressure 6.8 bar. Cold water use only.
Range of copper press fittings with EPDM ‘O’-rings for use with EN1057 copper tube. The joints are achieved by means of a press tool. For above and below ground use. Maximum working pressure 16.0 bar. Maximum operating temperature 85°C.
Instantor range of stainless-steel crimp fittings incorporating EPDM and ‘O’-rings. For use with stainless steel tube. Maximum working pressure 16.0 bar. Maximum operating temperature 95°C.
Range of brass press-fit fittings incorporating EPDM ‘O’-Rings and stainless steel crimp sleeves for use with Herz multi-layer PE-RT pipes. Maximum working pressure 10 bar. Maximum operating temperature 95°C.
Range of solder ring copper fittings for use with copper tube to EN 1057. Maximum working pressure 16.0 bar. Maximum operating temperature 85°C.
Range of solder ring copper fittings for use with EN1057 copper tube. Maximum working pressure and temperature for 15mm to 54mm 25 bar @ 30°C, 16 bar @ 65°C & 10 bar @ 100°.
CB Range of solder ring brass fittings for use with copper tube (manufactured to EN 1057). Maximum working pressure 16.0 bar. Maximum operating temperature 85°C.
Range of brass compression fittings incorporating brass ring olive to be used with pipe manufactured to EN ISO 15875. Maximum working pressure 8.0 bar. Maximum operating temperature 90°C.
Range of ductile iron pipe couplings for use with stainless steel and carbon steel pipe. The carbon steel pipe must incorporate a suitable coating or lining for wholesome water use. For maximum working pressure and the type of pipe the fittings are for use with, please refer to model. For above and below ground use. Maximum operating temperature 65°C.
Elysee range of polypropolene fittings for use with PE pipe (manufactured to EN 12201). Maximum working pressure 16 bar. Cold water use.
Range of stainless steel (SS316L) pressfit fittings with EPDM ‘O’-rings for use with stainless steel pipe (manufactured to EN10312). Maximum working pressure 16.0 bar. Maximum operating temperature 100°C.
Range of copper end feed fittings for use with copper tube. For above and below ground use. Maximum working pressure 25.0 bar. Maximum operating temperature 99°C.
Range of copper end feed fittings for use with copper tube manufactured to EN1057 For above and below ground use. 5mm to 54mm = Maximum working pressure 25.0 bar. 67mm to 159mm = Maximum working pressure 16.0 bar. Maximum operating temperature 100°C
CB (CENTRE) Range of end feed copper fittings for use with copper tube to EN 1057. Maximum working pressure 16.0 bar. Maximum operating temperature 85°C.
Range of end feed brass fittings for use with copper tube (manufactured to EN 1057). Maximum working pressure 16.0 bar. Maximum operating temperature 85°C.
Range of cross and parallel flow water plate heat exchangers with stainless steel bodies. Maximum working pressure primary circuit: 3.0 bar, secondary circuit: 10.0 bar. Maximum operating temperature 80°C.
Range of pressure limiter with stainless steel spring, plastic or chrome plated brass bodies. A5.0022.0 and A5.0027.0 incorporate with a stainless-steel mesh filter. Maximum working pressure 10.0 Bar. Maximum operating temperature 65˚C.
Range of hand shower sets comprising of a wall mounted elbow, shower hose, shower handset and shower holder. The shower handset has a chrome plated plastic body and the inlet incorporates a stainless steel strainer and approved check valve cartridge however, the complete product has not been fully tested to demonstrate it provides backflow protection. The elbow incorporates a quarter turn ceramic disc headwork with dome type operating member and an approved check valve cartridge however, the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.
Range of shower handsets with chrome plated ABS bodies incorporating NBR o rings. Maximum operating temperature 60°C.
Overhead shower outlets with chrome plated brass bodies, incorporating EPDM O rings. Maximum operating temperature 65.0°C
Range of shower handsets with chrome plated plastic bodies and EPDM O-rings. The inlets incorporate a plastic strainer. Maximum operating temperature 60°C.
Range of disposable shower kits, consisting of shower handset and shower hose with EPDM ‘O’-rings. Maximum operating temperature 65.0°C.
Range of multi-function shower handsets with white or chrome plated plastic bodies. The inlet incorporates a plastic flow regulator. Maximum operating temperature 60°C.
Wall mounted shower outlet with chrome plated body. The inlet incorporates a flow regulator and an approved check valve cartridge, however, the complete product has not been fully tested to demonstrate it provides backflow prevention. Maximum operating temperature 60°C
Range of shower outlets and shower arms (brass bodies - various finishes - see model). The wall mounted and ceiling mounted shower heads incorporate integral plastic flow regulators and also include stainless steel strainers on the inlets. The shower handset has a plastic flow regulator and a stainless steel strainer on the inlet. Maximum operating temperature 60°C.
Range of Y type strainers with blue epoxy coated ductile iron bodies and EPDM ‘O’-rings. Maximum working pressure 25.0 bar. Maximum operating temperature 85°C
Stainless steel bodied flow switch, with integral plastic plunger. Maximum working pressure 16.0 bar. Maximum operating temperature 80°C.
Range of hose union, spherical valve type bib taps with (nickel plated) brass bodies and chrome plated brass ball. The outlet incporates a plastic flow straightener Maximum working pressure 10.0 bar. Maximum operating temperature 85°C.
Range of basin pillar taps (chrome plated brass bodies) with quarter turn ceramic disc headworks with cross-top operating members. The products are supplied with metal backnuts. Maximum working pressure 10.0 bar. Maximum operating temperature 65°C.
Page 45 of 158
We use cookies to give you the best possible experience with WRAS. Some are essential to provide website functions and ensure the website is secure. We also use cookies to help us understand how people use the site and to make improvements. Click "Accept All" to enable recommended settings or click "Manage cookies" to adjust your settings. For more details, see our Cookie Policy.