Range of two hole, single outlet (fixed) combination tap assemblies (chromium plated brass), incorporating quarter turn ceramic disc headwork with single lever operating member. The spout outlet incorporates a plastic flow straightener. The products are supplied with metal back nuts. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.
Range of two-hole, single outlet (fixed) combination tap assemblies incorporating chrome plated brass bodies, quarter turn ceramic disc headworks with single lever operating members and a manual diverter to shower outlet. The spout outlet incorporates a plastic flow straightener. The product is supplied with metal backnuts, shower hose and handset. Maximum working pressure 10.0 bar Maximum operating temperature 70°C
Two-hole, single outlet (fixed) combination tap assemblies (chromium plated brass), incorporating quarter turn ceramic disc or ceramic cartridge headworks with single lever Operating members and manual diverter to shower outlet. The spout outlet incorporates a plastic flow straightener. The products are supplied with metal back nuts. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.
Range of two-hole, single outlet (fixed) combination tap assemblies (chromium plated brass), incorporating quarter turn ceramic disc or ceramic cartridge headworks various operating members (see models) and a manual diverter to shower outlet. The spout outlet either incorporates a plastic flow straightener, plastic aerator or an open outlet (see models). The products are supplied with metal back nuts. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.
Two-hole, single outlet (fixed) combination tap assembly (chromium plated brass), incorporating quarter turn ceramic disc headworks with single lever operating members and a self-cancelling diverter to shower outlet. The spout outlet incorporates a plastic flow straightener. The product is supplied with a shower hose and handset and metal back nuts. Maximum working pressure 6.0 bar. Maximum operating temperature 60°C.
Range of two-hole, single outlet (fixed) combination tap assemblies (chromium plated brass), incorporating quarter turn ceramic disc headworks with single lever operating members and a self-cancelling diverter to shower outlet. The spout outlet incorporates a plastic flow straightener. The4E6008 and 4E6017 models are also supplied with an optional plastic aerator. The products are supplied with a shower hose and handset and metal back nuts. Maximum working pressure 6.0 bar. Maximum operating temperature 60°C.
Two-hole, single outlet (fixed) combination tap assembly (chrome plated brass), incorporating quarter turn ceramic disc headworks with single lever operating members and a self-cancelling diverter to the shower outlet. The spout outlet incorporates a plastic flow straightener. The product is supplied with a shower hose and handset and metal back nuts. Models VAL2 BSM E6 C CD & VAL2 BSM E8 C CD come supplied with flow restrictors. Maximum working pressure 10.0 bar. Maximum operating temperature 70°C
Range of wall mounted two-hole, single outlet (fixed), combination tap assemblies incorporating brass bodies (various finishes), ceramic cartridge headwork with a single lever operating member and a self-cancelling diverter to shower outlet. The spout outlets incorporate plastic aerators. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.
Two-hole, single outlet (fixed) combination tap assembly (chrome plated brass), incorporating quarter turn ceramic disc headworks with single lever operating members and a self-cancelling diverter to the shower outlet. The spout outlet incorporates a plastic flow straightener. The product is supplied with a shower hose and handset and metal back nuts. Maximum working pressure 10.0 bar. Maximum operating temperature 70°C
Range of two hole, single outlet (swivel) combination tap assembly with brass bodies (chrome plated), incorporating quarter turn ceramic disc headworks and single lever operating members (model 1607023) or non-rising spindle headworks with dome type operating member (model 167021). The spout outlet incorporates a plastic aerator or plastic flow straightener. The product is supplied with metal backnuts. Maximum working pressure 10.0 bar. Maximum operating temperature 65°C.
Range of two hole, single outlet (fixed) combination tap assemblies with brass bodies (chrome plated), incorporating quarter turn ceramic disc headwork with single lever operating members and lockable diverter to shower outlet. The spout outlet incorporates a plastic aerator. The product includes a shower hose, shower handset and is supplied with metal backnuts. Model PAX106 is also supplied with a flow regulator. Maximum working pressure 6.0 bar. Maximum operating temperature 65°C.
Three-hole, single outlet (fixed) combination tap assembly with a brass body (various finishes) incorporating quarter turn ceramic disc headwork. The spout outlet incorporates a plastic aerator. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.
Range of three-hole, single outlet (fixed) combination tap assemblies with brass bodies (various finishes) incorporating a quarter turn ceramic disc headworks with single lever operating members. The spout outlets incorporate plastic aerators. Some models are supplied with lever operated pop-up wastes. Maximum working pressure 5.0 bar
Non-metallic materials and components comply with BS6920 at 60°C
Range of three hole, single outlet (fixed) combination tap assemblies (chromium plated brass) incorporating quarter turn ceramic disc headworks with single lever operating. The spout outlet incorporates an aerator or a flow straightener. Product supplied with stainless steel braided EPDM lined flexible connection hoses. Maximum working pressure 3.5 Bar. Maximum operating temperature 60°C.
Four-hole, single outlet (fixed) combination tap assembly (chromium plated brass), incorporating a ceramic cartridge headwork with a single lever operating member and self-cancelling diverter to shower outlet. The spout incorporates a flow restrictor on the inlet and a plastic aerator at the outlet. The product is supplied with a shower hose, handset and metal backnuts. The inlets of the handset and diverter incorporate an approved single check valve cartridge, verified by test, suitable for backflow to fluid category 2. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.
Five-hole, single outlet, fixed combination tap assembly (chromium plated brass) with quarter turn ceramic disc headworks with dome type operating members. The spout inlet has a plastic flow regulator the spout outlet incorporates a plastic aerator. The self-cancelling diverter, shower outlet and the shower handset incorporate an approved check valve cartridge, verified by test, suitable for backflow to fluid category 2. The product is supplied with metal back nuts, shower hose and shower handset. Maximum working pressure 10 bar. Maximum working temperature 60°C
Range of wall mounted spout outlets incorporating chrome plated brass bodies (model F2929.WR & F2418.WR) or a stainless-steel body (model F2944INOX.WR). The outlets incorporate a plastic flow straightener (model F2929.WR) or a plastic aerator (models F2418.WR & F2944INOX.WR) Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.
Range of deck mounted spout outlets incorporating chrome plated brass body (model F2158.WR) or a stainless-steel body (model F2943INOX.WR). The outlets incorporate a plastic flow straightener. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.
Range of wall mounted spout outlets incorporating chrome plated brass bodies (models CPHSP2929, ZCPHSP2929, CPHMA2418 & ZCPHMA2418) or a stainless-steel body (models CPHSP2944SS & ZCPHSP2944SS). The outlets incorporate a plastic flow straightener (models CPHSP2929 & ZCPHSP2929) or a plastic aerator (models CPHMA2418, ZCPHMA2418, CPHSP2944SS & ZCPHSP2944SS) Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.
Range of deck mounted spout outlets incorporating chrome plated brass body (models CPHSP2158 & ZCPHSP2158) or a stainless-steel body (models CPHSP2943SS & ZCPHSP2943SS). The outlets incorporate a plastic flow straightener. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.
Range of horizontal or vertical expansion vessels with an EPDM membrane. Maximum working pressure 10.0 or 16.0 bar (please refer to model). Maximum operating temperature 100°C.
Filling loop assemblies comprising of a stainless steel braided, EPDM lined hose, double check valve assembly with isolation valve verified by test (suitable for backflow protection against fluid category 3) and either a straight or tee isolation valve. Maximum working pressure 10.0 bar. Maximum operating temperature 85ºC.
Range of tap outlets with plastic bodies incorporating a filter within the body, incorporating a hollow fibre filter membrane. The inlet of the filter incorporates an approved check valve cartridge, however, the complete product has not been fully tested to demonstrate it provides backflow protection. The filters are supplied with (and must be used with) a chrome plated brass adapter which incorporates a pastic flow regulator. Maximum operating temperature 60°C.
Range of copper press fittings with EPDM ‘O’-rings for use with EN1057 copper tube. The joints are achieved by means of a press tool. For above and below ground use. Maximum working pressure 16.0 bar. Maximum operating temperature 85°C.
Wavin range of Tigris K1 (plastic bodies) and M1 (brass bodies) press-fit fittings for use with Tigris PEX/AL/PE HD (50mm & 63mm) and Tigris PERT/AL/PERT WT (75mm) barrier pipes. Maximum working pressure 6.0 bar. Maximum operating temperature 95°C.
Range of solder ring copper fittings for use with copper tube to EN 1057. The HLSRDPMFWT and HLSRDPMFZT models incorporate a captive nut on one end with a fibre gasket washer. Maximum working pressure 16.0 bar. Maximum operating temperature 85°C.
Range of solder ring brass fittings for use with copper tube (manufactured to EN 1057). The HLSR20CB-d tank connector incorporates an EPDM washer. Maximum working pressure 16.0 bar. Maximum operating temperature 85°C.
The 3G Metric Imperial range of plastic compression fittings with polypropylene bodies, compression nut and silicone seal for use with PE80 pipe (manufactured to BS EN 12201). Maximum working pressure: Fittings when used with PE100 pipe = 16.0 bar. Fittings when used with PE80 pipe = 12.0 bar. For above and below ground and cold water use only.
Range of ‘StrengThin™’ 100 System couplings and fittings for use with stainless steel pipe (manufactured to EN 10217-7). For above and below ground use. Maximum working pressure 16.0 bar. Maximum operating temperature 65°C.
Kuterlite K900 Pro range of compression fittings with DZR brass bodies for use with copper pipe (EN 1254) Maximum working pressure for 8mm-10mm = 70.0 bar. Maximum working pressure for 12mm – 28mm = 20.0 bar. Maximum working pressure for 35mm – 54mm = 6.0 bar. Maximum operating temperature 90°C.
Range of copper and DZR brass press fit tap connectors for use with copper tube (manufactured to EN1057). Maximum working pressure 16.0 bar. Maximum operating temperature 85°C.
Range of end feed brass fittings for use with copper tube (manufactured to EN 1057). The HLE20CB-d tank connector incorporates an EPDM washer. Maximum working pressure 16.0 bar. Maximum operating temperature 85°C.
Range of end feed copper fittings for use with copper tube to EN 1057. The HLDPMFWT and HLDPMFZT models incorporate a captive nut on one end with a fibre gasket washer. Maximum working pressure 16.0 bar. Maximum operating temperature 85°C.
Range of end feed copper or gunmetal solder fittings for use with copper pipe. Maximum working pressure 16.0 bar (Sizes 8 - 28mm). Maximum working pressure 10.0 bar (Sizes 35 - 108mm). Maximum operating temperature 100°C.
WC dual flush outlet valve comprising of ABS plastic body, EPDM gasket and an internal overflow. Cold water use only
Range of heat exchangers connected to copper waste pipe, Where the waste is discharged down a “rotator” into a copper waste pipe, and potable water is returned to the shower/heating device via a copper double walled jacket around the copper waste pipe. Maximum working pressure 8.0 bar. Maximum operating temperature 60°C
Range of 4 or 6 port manifolds with or without water meter manifolds (see model), all with gunmetal bodies. Models with a water meter manifold incorporate a quarter turn stop valve or screw down stop valve (see model), and an approved check valve cartridge however, the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum working pressure 16.0 bar. Cold water use only.
Range of click type pop-up wastes with brass bodies. Maximum operating temperature 60°C.
Range of installation kits with brass bodies. Maximum working pressure 5.0 bar. Maximum operating temperature 85°C.
Range of brass (chrome plated) quick fit connectors. Maximum operating temperature 60°C
Range of horizontal self-priming multistage pumps with stainless steel bodies, stainless steel impellers, shaft and outer sleeve. Maximum working pressure 10.0 Bar Maximum operating temperatures: EH Three phase models 85°C, EH Single phase models 55.0°C and EHsp models 35°C.
‘3ME’ Range of horizontal pumps with stainless steel bodies and impellers, and EPDM ‘O’-rings. The products are supplied with a carbon/ceramic/EPDM shaft seal. Maximum working pressure 10.0 bar. Maximum operating temperature 100°C.
Range of overhead shower outlets with brass bodies (various finishes - see model). Model 27 390 xxx is ceiling mounted. Model 27 437 xxx is wall mounted. The inlet incorporates stainless steel strainer and an approved check valve cartridge however, the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum operating temperature 60°C.
Range of handshower holders with brass bodies (various finishes). The outlet incorporates an approved check valve cartridge, however, the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum operating temperature 65°C
Range of shower heads with brass bodies (various finishes), incorporating EPDM ‘O’-rings and plastic flow regulator. Maximum operating temperature 60°C.
Range of shower handsets (various finishes) incorporating stainless steel strainers. Model 28 588 xxx incorporates flow regulator. Maximum operating temperature 60°C.
Range of drain taps incorporating brass bodies, EPDM seats and washers and a non-rising spindle headwork. Maximum working pressure 10.0 bar. Maximum operating temperature 85°C.
Range of pillar taps (chrome plated brass) incorporating quarter turn ceramic disc headworks with cross-top operating members. The product is supplied with metal backnuts. Maximum working pressure 10.0 bar. Maximum operating temperature 65°C.
Range of pillar taps (chrome plated brass) with quarter turn ceramic disc headworks and single lever operating members. The products are supplied with metal backnuts. Maximum working pressure 10.0 bar. Maximum operating temperature 65°C.
Range of pillar taps incorporating brass bodies (chrome plated), and quarter turn ceramic disc headowks. The spout outlet incorporates a flow straightener. Maximum working pressure 6.0 bar. Maximum operating temperature 60°C.
Page 38 of 209
We use cookies to give you the best possible experience with WRAS. Some are essential to provide website functions and ensure the website is secure. We also use cookies to help us understand how people use the site and to make improvements. Click "Accept All" to enable recommended settings or click "Manage cookies" to adjust your settings. For more details, see our Cookie Policy.