Range of two-hole, single outlet (fixed) combination tap assemblies (chrome plated brass bodies), incorporating quarter turn ceramic disc headworks with dome operating members. The spout outlets incorporate plastic aerators or flow straighteners. The product is supplied with metal back nuts. Maximum working pressure – 10.0 Bar Maximum operating temperature - 70 °C
Range of wall mounted, three-hole, single outlet (fixed) combination tap assemblies (brass bodies – various finishes), incorporating quarter turn ceramic disc headworks with single lever operating members. The spout outlets incorporate plastic aerators. Maximum working pressure 8.0 Bar. Maximum operating temperature 60°C
Range of wall mounted spout outlets (brass bodies - various plated) incorporating a plastic aerator. Maximum operating temperature: 60 °C
Wall mounted spout outlet, (chromium plated brass body) incorporating a plastic aerator. Maximum operating temperature 60°C.
Range of Grohe ‘Atrio’ wall mounted spout outlets (brass bodies - various finishes), the outlet incorporates a plastic aerator. Maximum operating temperature: 60°C
Filling loop assembly consisting of an in-line isolation valve, an in-line double check valve assembly which incorporates an isolation valve (suitable for back flow protection against fluid category 3) and a stainless steel braided EPDM lined hose. Maximum working pressure 10.0 bar. Maximum operating temperature 85°C.
The products incorporate two check valve cartridges, verified by test (suitable for backflow protection against Fluid Category 3), a pressure reducing valve adjustable between 1.0 bar and 3.0 bar (but pre-set at 2.5 bar for 523.815 model and 1.4 bar for the 523.816 model). The product incorporates a push type valve which allows water to flow when operated until the required pressure is achieved. There is a drain port below the push valve piston chamber. Compression connections are for use with copper pipe (manufactured to EN 1057). Maximum supply pressure 10.0 bar. Maximum operating temperature 80°C.
Inline filter with plastic body. Maximum working pressure 5.0 bar. Cold water use only.
Range of in-line carbon block water filters and housings with polypropylene bodies. Maximum working pressure 8.0 bar. Cold water use only.
Range of brass press fittings (TH and U crimp profiles) for use with RIIFO B1 PEX/AL/PEX multilayer pipe. Maximum working pressure: 10 bar Maximum operating temperature: 95 °C
Range of copper press fittings with EPDM ‘O’-rings for use with EN1057 copper tube. The joints are achieved by means of a press tool. For above and below ground use (sizes 12mm-54mm only. 66.7mm, 76.1mm, 88.9mm & 108mm for above ground use only) Maximum working pressure 16.0 bar. Maximum operating temperature 85°C.
Range of PCC type press copper crimp fittings with EPDM ‘O’-rings for use with copper tube manufactured to EN 1057. The joints are achieved by means of a crimping tool. For above ground use. Maximum working pressure: 16.0 bar. Maximum operating temperature: 85°C
Range of CU type press copper crimp fittings with EPDM ‘O’-rings for use with copper tube manufactured to EN 1057. The joints are achieved by means of a crimping tool. For above ground use. Maximum working pressure: 16.0 bar. Maximum operating temperature: 85°C
Tectite Classic and Tectite Pro ranges of copper alloy push-fit fittings The Tectite Classic range is for use with copper tube (manufactured to BS EN 1057) and PEX & Polybutylene tube (manufactured to BS 7291). The fittings are supplied with plastic inserts. The Tectite Pro range is for use with copper tube (manufactured to BS EN 1057). Maximum working pressures & operating temperatures: Tectite Classic fittings with copper pipe: 6.0 bar @ 95°C, 16.0 Bar cold water use. Tectite Classic fittings with PEX & Polybutylene 6.0 bar @ 95°C, 12.0 Bar cold water use. Tectite Pro fittings (15mm - 28mm): 6.0 bar @ 95°C, 20.0 Bar cold water use. Tectite Pro fittings (32mm - 54mm): 6.0 bar @ 95°C, 16.0 Bar cold water use.
Range of urinal flushing mechanisms, consisting of a solenoid valve controlling the flow which is actuated via an infra-red sensor. Models are either mains or battery operated and are available in a variety of enclosure options Maximum operating pressure 8 bar. Maximum operating temperature 23°C
Range of ultrasonic water meters with brass or stainless steel bodies and plastic or stainless steel transducers. The SC-F models incorporate a spherical valve operated via a motor controlled by computer software. Maximum working pressure 16.0 bar. Maximum operating temperature 85°C.
Range of electromagnetic water meters with stainless steel bodies and natural rubber liners. Maximum working pressure 10.0 Bar Maximum operating temperature 50.0°C
Range of in-line single jet water meters with brass bodies. Products incorporate plastic strainers. Maximum working pressure: 16.0 Bar. Maximum operating temperature: 85.0°C.
Range of ultrasonic water meters with brass bodies. The products incorporate a motorised butterfly valve on the outlet. Maximum working pressure 16.0 bar. Maximum operating temperature 85°C.
Water meter manifold with a gunmetal body. The product incorporates a non-return valve (not suitable for backflow protection) and a spherical valve on the inlet. Maximum working pressure 16.0 bar. Cold water use only.
Range of shower booster pumps with brass bodies and plastic impellers. The body incorporates a single check valve cartridge, however the complete assembly has not been tested to demonstrate it provides adequate backflow protection. Maximum working pressure: 4.0 bar. Maximum operating temperature: 70°C.
‘UPM10’ and ‘UPM20’ range of circulator pumps with a stainless-steel body, plastic impellor and EPDM ‘O’-rings. The product is supplied with EPDM gaskets for the inlet and outlet. Maximum working pressure 10.0 bar. Maximum operating temperature 95°C.
'HYDRO MULTI-E' booster set range consisting of two to four electronically controlled pumps connected in parallel and mounted on a common base frame provided with all necessary fittings. The suction manifold incorporates an isolation valve fitted between it and the individual pumps, and a pressure switch with an isolation valve. The discharge manifold incorporates an isolation valve and a non-return valve (not suitable for backflow protection), which is fitted between it and the individual pumps, it also incorporates a combined isolation and drain valve. Maximum working pressure 16.0 bar. Cold water use only.
Self-priming single stage pump, with stainless steel body, plastic impellers, stainless steel shaft, NBR 'O'-rings and seals. Maximum working pressure 6.0 bar. Maximum operating temperature 45°C.
Dutypoint ‘VMV’ range of cold water supply booster sets, incorporating 2 to 8 pumps with a modular stainless steel manifold system. VMV2, VMV3 and VMV4 pump sets are available with DN80 to DN150 manifolds depending on application. VMV5, VMV6, VMV7 and VMV8 pump sets are available with DN150 to DN200 manifolds, depending on application. The products incorporate spherical valves on both the suction and discharge manifolds, with expansion vessels, isolation valves, pressure gauges and transducers on the discharge manifolds only. Maximum working pressure 16.0 bar. Cold water use only.
Range of pumps with plastic bodies, pistons and TPE diaphragm. For use with John Guest LLDPE pipe. The products incorporate non-return valves (not suitable for backflow protection). Maximum working pressure: 8.27 Bar. Cold water use only.
Range of horizontal multistage pumps with stainless steel bodies, diffuser and impellers and EPDM ‘O’-rings. The products incorporate a graphite-SiC-EPDM shaft seal. The products incorporate a drain plug. Maximum working pressure 8.5 bar. 9Maximum operating temperature 80°C.
Range of shower handsets with ABS plastic bodies (various finishes, see models). Maximum operating temperature (see models).
Range of plastic bodied shower outlets, available in chrome plated or black finish (AQ055082 and B suffix models only). The overhead showers incorporate a combined silicone washer and stainless steel strainer on the inlet. Maximum operating temperatures: 65°C (AQ055062, AQ055063 & AQ055081 models). 75°C (all other models).
Range of overhead shower outlets with (brass bodies – various finishes) incorporating stainless-steel filter washers at the inlet. Maximum operating temperature 85°C.
Range of wall mounted shower outlets (chrome plated brass bodies). Maximum operating temperature 85°C.
Concealed, ceiling mounted installation sets and shower outlets. The inlets incorporate a plastic flow regulator. Maximum operating temperature 60°C.
Range of shower handsets (plastic bodies – various finishes), incorporating a plastic flow regulator on the inlet. Open outlet use only. Maximum operating temperature: 60 °C
Range of overhead shower outlets with brass bodies (various finishes). The inlet incorporates a plastic flow regulator and stainless steel strainer. Maximum operating temperature 60°C
Range of shower handsets incorporating chromium plated ABS plastic bodies. The inlets incorporate an approved check valve cartridge however, the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum operating temperature 60.0°C
Range of shower handsets with plastic bodies incorporating an integral filter. The inlet incorporates a combined washer and a strainer, plastic flow regulator and an approved check valve cartridge, however, the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum operating temperature 60°C. Open outlet use only.
Range of In-line ‘Y’ patterned strainer with ductile iron bodies (blue epoxy powder coated) and stainless-steel screens. Maximum working pressure 16.0 bar. Maximum operating temperature 85ºC.
Range of In-line Y patterned strainers with ductle iron bodies (blue epoxy powder coated) and stainless-steel mesh. Maximum working pressure: 16 Bar Maximum operating temperature: 85 °C
Range of wall mounted bib taps (chromium plated brass), incorporating a non-rising spindle headwork with a cross top operating member. The spout outlet incorporates a plastic flow straightener. Maximum working pressure 10.0 bar. Maximum working temperature 85°C.
Wall mounted, single hole, single outlet (fixed) bib tap (chromium plated brass), incorporating a non-rising spindle with a single lever operating member. The outlet incorporates a metal flow straightener. Maximum working pressure 10 Bar. Maximum operating temperature 85°C.
Self closing basin tap (chromium plated brass) with spring loaded headwork and dome type operating members. The spout outlets incorporate a plastic flow straightener and the products are supplied with metal backnuts. Maximum working pressure 10.0 bar, Maximum operating temperature 85°C.
Range of stainless steel interlocked or PVC reinforced (see models), PVC inner lined flexible hose assemblies (various finishes). Open outlet use only. Maximum operating temperature 65°C.
Range of plastic braided PEX lined flexible hose assemblies. Maximum working pressure 10.0 bar. Maximum operating temperature 85°C.
Range of stainless steel braided, PEX lined, flexible hose assemblies. Maximum working pressure 10.0 bar. Maximum operating temperature 85°C.
Range of stainless steel braided PEX lined flexible hose assemblies. The captive nut and M15x1 end connections incorporate a washer. The M8x1, M10x1 and M12x1 end connections incorporate an ‘O’-ring. Maximum working pressure 10.0 bar. Maximum operating temperature 85°C.
Range of stainless steel inter-locked shower hoses incorporating an EPDM inner liner and EPDM gaskets. Maximum operating temperature 85°C.
Range of stainless-steel braided EPDM lined flexible hose assemblies with EPDM seals, available with a variety of end connections, some of which include isolation valves (see model). For use with: Copper Pipes manufactured in accordance with BS EN 1057 Plastic PB pipes manufactured in accordance with BS 7291-2 Plastic PEX pipes manufactured in accordance with BS 7291-3 Maximum working pressure: 6.0 bar @ 65°C Maximum working pressure: 12.0 bar @ 20°C
Nimbus Compact range of combination heat pump units with enamel lined tank and stainless-steel coil. Fitted with a magnesium anode, expansion vessel and T&P valve set at 7 bar & 95°C. supplied with an inlet control group consisting of a pressure reducing valve, strainer, pressure relief valve and single check valve, and a tundish. Max working pressure 6.0 Bar Max operating Temperature 80 °C
Unvented hot water cylinder for domestic hot water 180 litre and buffer vessel 70 litre comprised of stainless steel main body, a stainless steel buffer cylinder 7 bar max working pressure max operating temperature 90°C. The cylinder is fitted with a T & P valve and supplied with an inlet control group consisting of pressure reducing, a pre-set expansion relief and incorporates a check valve cartridge, verified by test (suitable for backflow protection against Fluid Category 2). Max working pressure 7.0 Bar. Max operating temperature 90°C.
Range of stainless steel hot water buffer tanks. Maximum working pressure 6.0 bar. Maximum operating temperature 95°C.
Page 127 of 158
We use cookies to give you the best possible experience with WRAS. Some are essential to provide website functions and ensure the website is secure. We also use cookies to help us understand how people use the site and to make improvements. Click "Accept All" to enable recommended settings or click "Manage cookies" to adjust your settings. For more details, see our Cookie Policy.