Uponor S-Press press fittings, Uni-X & Uni-C compression fittings for use with Uponor MLC pipe. Maximum working pressure 10.0 bar, maximum operating temperature 70°C.
‘ISR’ range of copper, DZR brass or gunmetal capillary, lead free solder ring and threaded fittings for use with copper pipe. For above ground use only. Maximum working pressure 16.0 bar. Maximum working temperatures 99°C.
‘CB ISR’ range of capillary fittings with internal solder rings, DZR brass or gunmetal capillary, lead free solder ring and threaded fittings for use with copper pipe. For above ground use only. Maximum working pressure 16.0 bar. Maximum working temperatures 99°C.
Range of copper and bronze capillary brazed fittings for use with copper pipe manufactured to EN1057:2006 +A1:2010. Maximum pressure 10.0 Bar (54mm up to and including 108mm) Maximum pressure 2.0 Bar (Over 108mm up to and including 159mm) Maximum operating temperature 100°C.
Range of brass compression fittings for use with copper pipe to EN1057. Maximum working pressure 16.0 bar. Maximum operating temperature 100°C.
Range of press fittings incorporating copper or copper alloy bodies and EPDM O’-rings for use with copper tube to EN1057. Maximum working pressure 16.0 bar. Maximum operating temperature 85°C.
Range of end feed copper fittings for use with copper tube. Maximum working pressure 16.0 bar. Maximum operating temperature 95°C.
Range of stainless-steel plate heat exchangers with copper brazing. Maximum working pressure 30.0 Bar. Maximum operating temperature 100°C.
Range of stainless steel, copper brazed plate type heat exchangers. Maximum working pressure 30.0 bar. Maximum operating temperature 100°C.
Electronically controlled heat interface units (HIU) with twin stainless-steel plate heat exchangers providing space heating and instantaneous hot water. The cold inlet supply to the plate heat exchanger incorporates an isolation valve. The space heating circuit incorporates an expansion vessel and a pressure relief valve (set at 3.0 bar). The inlet and outlet of all circuits incorporates lever operated spherical valves with brass bodies. 274.xx9x.696 models all have the following additional items over the 274.xx1x.696 models: Heatmeter on the primary circuit, a flushing bypass between the primary and space heating circuits and a safety relief valve (set at 10.0 bar) on the cold supply to the heat exchanger of the domestic hot water circuit. Maximum working pressures and operating temperatures: Primary: 16.0 bar and 90˚C. Domestic hot water (DHW): 9.5 bar and 60˚C. Secondary (space heating): 2.5 bar and 85˚C.
Uponor Combi Port range of indirect heat interface units providing heating and instantaneous hot water. The heating system incorporates an expansion vessel and pressure relief valve (set at 3.0 bar).Some units have optional ball valve sets. Primary side heating 85°C and 2.5 bar. Secondary side, space heating 60°C and 2.5 bar. Secondary side DHW 60°C and 4.0 bar.
Range of copper brazed, stainless steel heat exchangers in various sizes (4-300 plates, see model). Models size X8T-SC-S Maximum working pressure primary circuit: 32.0 bar Maximum working pressure secondary circuit: 26.0 bar Maximum operating temperature: 99°C Models size 10T-SC-M Maximum working pressure primary circuit: 41.0 bar Maximum working pressure secondary circuit: 36.0 bar Maximum operating temperature: 99°C Models size 15T-SC-M Maximum working pressure primary circuit: 45.0 bar Maximum working pressure secondary circuit: 45 bar Maximum operating temperature: 99°C Models size 16DW-SC-S Maximum working pressure primary circuit: 16.0 bar Maximum working pressure secondary circuit: 16.0 bar Maximum operating temperature: 99°C Models size 16DW-SC-M Maximum working pressure primary circuit: 45.0 bar Maximum working pressure secondary circuit: 45.0 bar Maximum operating temperature: 99°C Models size 220-SC-S Maximum working pressure primary circuit: 25.0 bar Maximum working pressure secondary circuit: 25.0 bars Maximum operating temperature: 99°C Models size 320HT-SC-S Maximum working pressure primary circuit: 33.0 bar Maximum working pressure secondary circuit: 29.0 bar Maximum operating temperature: 99°C Models size 320LT-SC-S Maximum working pressure primary circuit: 33.0 bars Maximum working pressure secondary circuit: 29.0 bars Maximum operating temperature: 99°C
Range of wall mounted combination boilers providing domestic hot water via a plate heat exchanger and pressurised central heating system. Incorporating a pressure relief valve and expansion vessel. Primary circuit has a maximum working pressure of 3.5 bar and operating temperature of 85°C. Secondary circuit has a maximum working pressure of 10.0 bar and operating temperature of 60°C.
Plastic bodied flow sensor. Maximum working pressure 10.0 bar. Maximum operating temperature 85°C.
Wall mounted chrome plated brass elbow fitting. Maximum working pressure 5.0 bar. Maximum operating temperature 70°C.
Hygienic flush box providing a timed flush facility. The supply is via a single check valve cartridge however, the complete product has not been fully tested to demonstrate it provides backflow protection, flow sensor, spherical ball valve and strainer. The products incorporate a type `AB` airgap (verified by test - suitable for backflow protection against fluid category 5). The units have multiple interface user functions for timed flush, wireless technology and data storage. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.
Range of flow through valves with brass bodies and EPDM ‘O’-rings, incorporating a spherical valve and a separate drain tap. The products are intended for connection prior to an expansion vessel. Maximum working pressure 5.0 bar. Maximum operating temperature 85°C.
Range of water monitoring systems comprising of a battery or mains operated latching solenoid valve (plastic body) and a flow sensor. The units are supplied with a hand-held controller. Maximum working pressure 10.0 bar. Cold water use only.
Range of flow measurement devices (DZR brass) bodies incorporating two test ports. Maximum working pressure 25.0 bar. Maximum operating temperature 85°C.
Range of screwed gland cock valves with bronze bodies, EPDM seats and ‘O’-rings. The products incorporate a hose union outlet connection. Maximum working pressure 10.0 bar. Maximum operating temperature 100°C.
Flow sensor with a plastic body. Maximum working pressure 10.0 bar. Maximum operating temperature 85°C.
Self-priming electric booster pump with plastic body incorporating plastic impellers with variable speed settings, and a non-return return valve (not suitable for backflow protection). Maximum working pressure 8.0 bar. Cold water use only.
Range of central heating pumps incorporating polyether sulphone impellers, copper-tin alloy body, carbon graphite axial bearings and EPDM O-rings. Maximum working pressure 16.0 bar. Maximum operating temperature 99°C.
Range of interlocked EPDM lined shower hoses assemblies with EPDM gaskets. Maximum operating temperature is 85°C. bar.
A range of shower handsets with chromium plated plastic bodies and a plastic strainer and flow regulator in the inlet. Models may incorporate dark grey alternative shower plate. Maximum operating temperature 85°C.
Overhead, ceiling mounted shower outlet with chromium plated brass body (various finishes). Maximum operating temperature 60°C.
Shower handset incorporating a plastic body (chrome plated), brass wall connector (chrome plated) and shower hose. The inlet to the shower and wall connector incorporates approved check valve cartridges, however, the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum operating temperature 60°C.
Range of over head shower outlets incorporating brass bodies and an adjustable ball joint. The inlet incorporates a combined NBR washer and stainless-steel filter. Maximum operating temperature 60°C.
Range of wall mounted shower outlets (chromium plated brass). Models ARMW02 and ARMW05 are supplied with metal backnuts. Maximum operating pressure 10.0 bar. Maximum operating temperature 65°C.
Range of shower handsets with a chromium plated plastic body. The inlets incorporate a flow regulator. Maximum operating temperature 60°C.
Ceiling mounted shower outlet consisting of a (chrome plated) brass shower arm and a (chrome plated) stainless steel shower rose with an integral ball joint and silicone nozzles . The connection between the shower arm and the ball joint incorporates a combined EPDM washer and stainless steel strainer. The connection between the ball joint and the overhead shower incorporates a plastic flow regulator. Maximum operating temperature 60°C.
Range of overhead shower outlets with brass bodies (various finishes), with a ball joint, EPDM ‘O’-rings and a NBR seal. The inlet incorporates a plastic flow regulator. Maximum operating temperature 60°C.
Range of in-line `Y`-patterned strainers with either brass or DZR brass bodies (see model) incorporating a stainless steel mesh strainer and a PTFE washer. Maximum working pressure 25.0 Bar. Maximum operating temperature 99.0°C
In-line `Y`-patterned strainers with bronze bodies incorporating stainless steel mesh strainers and PTFE washers. Maximum working pressure 20.0 bar. Maximum operating temperature 85.0°C
Range of Y-patterned strainers incorporating ductile iron, blue epoxy coated bodies and stainless steel screen. Maximum working pressure 16.0 bar. Maximum operating temperature 85°C
Range of Y-patterned strainers incorporating ductile iron, blue epoxy coated bodies and stainless steel screen. Maximum working pressure 16.0 bar. Maximum operating temperature 85°C
Drain off valve with brass body (chrome plated) and NBR ‘O’-rings. Maximum working pressure 16.0 bar. Maximum operating temperature 99°C.
Range of drain off taps incorporating DZR brass bodies, non-rising spindle operating mechanism and EPDM ‘O’-rings and seat washer. D340 range incorporates a lockshield mechanism and the D341 range incorporates a key operated mechanism. Maximum working pressure 16.0 bar. Maximum operating temperature 85°C.
Pillar tap with brass body (various finishes), incorporating a quarter turn ceramic disc headwork and cross top operating member. The spout outlet incorporates an aerator. Maximum working pressure 10.0 bar. Maximum operating temperature is 60°C.
Range of wall mounted taps (chromium plated brass) incorporating non-rising spindle headworks with cross top operating members. Maximum working pressure 10.0 bar. Maximum operating temperature 65°C.
Range of pillar taps (chromium plated brass) incorporating non rising spindle headworks and cross top operating members. The spout outlets incorporate a plastic flow straightener. The products are supplied with metal backnuts. Maximum working pressure 10.0 bar. Maximum operating temperature 65°C.
Range of pillar taps (chromium plated brass) incorporating non rising spindle headworks and cross top operating members. The spout outlets incorporate a plastic flow straightener. The products are supplied with metal backnuts. Maximum working pressure 10.0 bar. Maximum operating temperature 65°C.
‘TAQ PEX’ range of PEX lined flexible hose assemblies with either stainless steel braiding or grey polymeric (PET - Polyethylene terephthalate) braiding (ACB suffix models). Models have either EPDM ‘O’-rings and/or EPDM or silicone washers (depending on end connection). Models are also available with an optional washer incorporating a stainless steel strainer. Maximum working pressure 10.0 bar. Maximum operating temperature 85°C.
Range of automatic air venting valves with a brass body and a plastic float. Maximum working pressure 10.0 bar. Maximum operating temperature 115°C.
Range of concealed flow controls (brass body with various different finishes) incorporating two, quarter turn ceramic disc headworks with single lever operating members controlling the flow to an external outlet (not supplied). Model BK2 is a flow control with adjustable bracket and collection box. Model BK2A is a flow control with bracket. Model BK2B is a flow control. Maximum working pressure 10.0 bar. Maximum operating temperature 70°C
Range of wall mounted thermostatic blending valves (chromium plated brass) incorporating either a 2 way ceramic disc diverter (models T43014, T44014 & T45004) controlling the flow to either an overhead shower or shower handset with various operating members (See model) or a quarter turn ceramic disc headwork (models T43014B, T43034 & T44014B) with various operating members. The temperature is controlled independently via a thermostatic cartridge incorporating a manual override button. The inlets incorporate approved check valve cartridge(s), however, the complete product has not been fully tested to demonstrate it provides backflow protection and stainless steel strainers. Maximum working pressure 5.0 bar. Maximum operating temperature is 85°C.
Shower kit consisting of a wall mounted thermostatic blending valve with a brass body (chrome plated), incorporating a single sequential headwork controlling both temperature and flow using a single lever operating member. Each inlet incorporates a stainless steel strainer and an approved check valve cartridge, however, the complete product has not been fully tested to demonstrate it provides backflow protection. The product is supplied with shower hose, shower handset, riser rail & soap tray. Maximum working pressure 5.0 bar. Maximum operating temperature 70°C.
Shower kit consisting of a wall mounted (concealed or exposed) thermostatic blending valve with a brass body (chrome plated). Flow is controlled by a quarter turn ceramic disc headwork with single lever operating member, temperature is controlled by a thermostatic cartridge with a dome type operating member which incorporates a manual override button. Each inlet incorporates a stainless steel strainer and an approved check valve cartridge, however, the complete product has not been fully tested to demonstrate it provides backflow protection. The product is supplied with shower hose, shower handset & riser rail. Maximum working pressure 10.0 bar. Maximum operating temperature 70°C.
Range of two hole wall mounted thermostatic bar type mixing valves with a chrome plated brass body, incorporating a quarter turn ceramic disc headwork with dome type operating member. The temperature is controlled independently via a thermostatic cartridge with dome type operating member that incorporates a manual override button. Inlets incorporate stainless steel strainers and approved check valve cartridges however, the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum working pressure 8.0 bar. Maximum operating temperature 60°C.
Range of wall mounted thermostatic blending valves with chrome plated brass bodies and ceramic disc headwork with a dome type operating member. Temperature is controlled independently via a thermostatis cartridge also with a dome type operating member. Inlets incorporate single check valve cartridges however, the complete assembly has not been tested to demonstrate it provides adequate backflow protection. Supplied with a shower, hose, handset and rail. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.
Page 2 of 158
We use cookies to give you the best possible experience with WRAS. Some are essential to provide website functions and ensure the website is secure. We also use cookies to help us understand how people use the site and to make improvements. Click "Accept All" to enable recommended settings or click "Manage cookies" to adjust your settings. For more details, see our Cookie Policy.