Range of stainless steel (SS316L) pressfit fittings with EPDM ‘O’-rings for use with stainless steel pipe (manufactured to EN10312). Maximum working pressure 16.0 bar. Maximum operating temperature 100°C.
Timco - Elysee range of Polypropolene fittings for use with PE pipe (manufactured to EN 12201). Maximum working pressure 16 bar. Cold water use.
Jason range of polypropolene fittings for use with PE pipe (manufactured to EN 12201). Maximum working pressure 16 bar. Cold water use.
CB (CENTRE) Range of end feed copper fittings for use with copper tube to EN 1057. Maximum working pressure 16.0 bar. Maximum operating temperature 85°C.
Range of end feed copper fittings for use with copper tube to EN 1057. The HLDPMFWT and HLDPMFZT models incorporate a captive nut on one end with a fibre gasket washer. Maximum working pressure 16.0 bar. Maximum operating temperature 85°C.
Range of end feed brass fittings for use with copper tube (manufactured to EN 1057). Maximum working pressure 16.0 bar. Maximum operating temperature 85°C.
Range of end feed copper fittings for use with copper tube to EN 1057. The 30065321,30065313, 30065317,30465313,30065301, 30065305, 30065309, 30465301 & 30465305 models incorporate a captive nut on one end with a fibre gasket washer. Maximum working pressure 16.0 bar. Maximum operating temperature 85°C.
Range of end feed copper fittings for use with copper tube to EN 1057. The 950513 & 950514 & 950501, 950503 & 953102 models incorporate a captive nut on one end with a fibre gasket washer. Maximum working pressure 16.0 bar. Maximum operating temperature 85°C.
Range of copper capillary, bronze or brass end feed fittings for use with copper pipe (manufactured to EN 1057). Maximum working pressure 16.0 bar. Maximum operating temperature 99°C.
Non-metallic materials and components comply with BS6920 at 99°C
Range of end feed copper fittings for use with copper tube to EN 1057. The 950513, 950514, 950501, 950503 & 950502 models incorporate a captive nut on one end with a fibre gasket washer. Maximum working pressure 16.0 bar. Maximum operating temperature 85°C.
Range of cross and parallel flow water plate heat exchangers with stainless steel bodies. Maximum working pressure primary circuit: 3.0 bar, secondary circuit: 10.0 bar. Maximum operating temperature 80°C.
Range of under-sink, electrically heated vented water heaters (cased and insulated). Maximum operating temperature 98˚C
Range of wall hung, gas fired, combination boilers providing domestic hot water via a plate heat exchanger. The primary circuit incorporates an integral expansion vessel and a pressure relief valve set at 3.0 bar. The product is supplied with a rigid pipe filling loop, followed by a separate isolation valve. The filling loop pipe attaches to the cold water inlet valve which incorporates a double check valve assembly (verified by test, suitable for backflow protection against Fluid Category 3) on the branch to the filling loop. The primary circuit includes an isolation valve on the flow and return and is also supplied with two loose 22mm compression isolation valves and a filter. Maximum working pressure of the primary circuit is 2.5 bar and the maximum supply pressure to the secondary circuit is 10.0 bar. Max operating temperature 65°C.
Range of wall hung, gas fired, combination boilers providing domestic hot water via a plate heat exchanger. The primary circuit incorporates an integral expansion vessel and a pressure relief valve set at 3.0 bar. The product is supplied with a rigid pipe filling loop, followed by a separate isolation valve. The filling loop pipe attaches to the cold water inlet valve which incorporates a double check valve assembly (verified by test, suitable for backflow protection against Fluid Category 3) on the branch to the filling loop. The primary circuit includes an isolation valve on the flow and return and is also supplied with two loose 22mm compression isolation valves and a filter. Maximum working pressure of the primary circuit is 2.5 bar and the maximum supply pressure to the secondary circuit is 10.0 bar. Max operating temperature 65°C.
Range of wall hung, gas fired, combination boilers providing domestic hot water via a plate heat exchanger. The primary circuit incorporates an integral expansion vessel and a pressure relief valve set at 3.0 bar. The product is supplied with a rigid pipe filling loop, followed by a separate isolation valve. The filling loop pipe attaches to the cold water inlet valve which incorporates a double check valve assembly (verified by test, suitable for backflow protection against Fluid Category 3) on the branch to the filling loop. The primary circuit includes an isolation valve on the flow and return and is also supplied with two loose 22mm compression isolation valves and a filter. Maximum working pressure of the primary circuit is 2.5 bar and the maximum supply pressure to the secondary circuit is 10.0 bar. Max operating temperature 65°C.
Mitsubishi PPSU elbow fitting with a quick connect clip. Maximum Working Pressure: 6 Bar Maximum Working Temperature: 80°C
Range of vertical multistage booster pumps, with stainless steel bodies and impellors. Maximum working pressure: See models Maximum working temperature 85°C.
Range of shower outlets and shower arms (brass bodies - various finishes - see model). The wall mounted and ceiling mounted shower heads incorporate integral plastic flow regulators and also include stainless steel strainers on the inlets. The shower handset has a plastic flow regulator and a stainless steel strainer on the inlet. Maximum operating temperature 60°C.
Range of shower handsets with a black plastic body and EPDM ‘O’-rings. Model includes a trigger mechanism that alters the spray pattern. Maximum operating temperature 60°C.
Range of shower handsets with plastic bodies (chrome plated or white finish). Maximum operating temperature 60.0°C
Overhead shower outlet with a chromium plated brass body. The inlet incorporates a plastic flow restrictor. Maximum operating temperature 60°C.
Range of overhead shower outlets (chrome plated brass bodies) supplied with 4, 6, 9 way connectors and stainless-steel or nylon braided EPDM lined flexible hoses.. Maximum operating temperature 60°C.Open outlet only
Overhead shower outlet with a chromium plated brass body. The inlet incorporates a plastic flow restrictor. Maximum operating temperature 60°C.
Overhead shower outlets with brass bodies (various finishes), incorporating EPDM O rings. Maximum working pressure: Open outlet Maximum operating temperature 60.0°C
Pillar taps (chromium plated brass) incorporating a quarter turn ceramic disc headwork with a single lever operating member. The spout outlets incorporate a plastic flow straightener. Model are supplied with plastic backnuts. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.
Range of PVC or EPDM lined shower hoses with stainless steel outer (chrome or black finish) or PVC reinforced (chrome plated finish) outer layer. Maximum operating temperature 65°C.
Range of CENTERSTORE AIR bubble top indirect and direct single coil unvented storage cylinders. The secondary circuit is factory fitted with a temperature and pressure relief valve set at 10.0 bar@90˚C. A safety kit (manifold) consisting of a single check valve assembly, verified by test (suitable for backflow prevention against fluid category 2), strainer, an expansion relief valve set at 8.0 bar and a pressure reducing valve set at 3.0 bar and a tundish is also provided. Alternative inlet control group and temperature and pressure relief valve added March 2023. Maximum working pressure: Secondary circuit: 7.5 bar. Primary circuit: 6.0 bar. Maximum operating temperature 65°C.
Range of wholesome-water nickel plated brass manifolds for use with ‘Emmeti Gerpex RA’ Pexb/Al/Pexb Multilayer pipe and ‘Emmeti Alpert’ PERT/AL/PERT Multilayer Pipe. Maximum working pressure 10.0 bar. Maximum operating temperature 95°C. Range of closed circuit use nickel plated brass manifolds for use with ‘JG Speedfit Layflat Polybutylene Barrier Pipe (models 10BPB & 15BPB)’. Maximum working pressure 3.0 bar. Maximum operating temperature 92°C.
Range of concealed manually operated blending valves (brass bodies with chromium plated exposed trim sets) incorporating self-cancelling diverters (except models added December 2023 – 36020626 & 36020832) ceramic cartridge headworks controlling both temperature and flow with a single lever operating member. The inlets and the outlet incorporate approved check valve cartridge however the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum working pressure 10.0 bar. Maximum operating temperature 80°C.
Range of T type thermostatic blending valves with DZR brass bodies and EPDM O-rings. The inlets incorporate stainless steel strainers and single check valve cartridges verified by test (suitable for backflow protection against Fluid Category 2). Maximum working pressure 10.0 bar. Maximum operating temperature 85°C
Wall mounted, thermostatic shower valve (chromium plated brass body) incorporating a two-way diverter valve headwork that controls flow between each shower outlet with a cube type operating member. The temperature is controlled independently via a thermostatic cartridge with a cube type operating member with a manual override button. Both inlets incorporate a stainless-steel strainer and approved check valve cartridges, however, the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum working pressure: 10.0 Bar. Maximum operating temperature: 85°C.
Wall mounted thermostatic shower valve (chromium plated brass bodies), incorporating a quarter turn ceramic disc headwork diverting the flow between overhead shower and handset with cube type operating member. Temperature is controlled independently via a thermostatic cartridge with a cube type operating member that incorporates a manual override button. The product incorporates a fixed riser and overhead shower and is supplied with a shower hose and handset. Both inlets incorporate stainless steel strainers and approved check valve cartridges, however, the complete products have not been fully tested to demonstrate that they provide backflow protection. Maximum working pressure: 5.0 Bar Maximum operating temperature: 60°C.
Range of wall mounted, concealed, thermostatic shower valves with cast brass bodies, incorporating a ceramic cartridge headwork controlling the flow with a single lever operating member. The temperature is controlled independently via a thermostatic cartridge with a single lever operating member. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.
Wall mounted thermostatic shower valve (chromium plated brass bodies), incorporating a quarter turn ceramic disc headwork diverting the flow between overhead shower and handset with dome type operating member. Temperature is controlled independently via a thermostatic cartridge with a dome type operating member that incorporates a manual override button. The product incorporates a fixed riser and overhead shower and is supplied with a shower hose and handset. Both inlets incorporate stainless steel strainers and approved check valve cartridges, however, the complete products have not been fully tested to demonstrate that they provide backflow protection. Maximum working pressure: 5.0 Bar Maximum operating temperature: 60°C.
Wall mounted, exposed, thermostatic shower mixing valve (chromium plated brass). The product incorporate a ¼ turn ceramic disc or a 2-way ceramic disc diverter headwork (see model). Temperature is controlled independently via a thermostatic cartridge with a manual override button. The product has a dome type operating member. Each inlet incorporates a combined EPDM washer and stainless steel strainer and an approved check valve cartridge, however, the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum working pressure 6.0 bar. Maximum operating temperature 65°C.
Range of wall mounted, thermostatic shower valves with brass bodies (various finishes), incorporating a thermostatic cartridge controlling the temperature and a push shut-off valve controlling the flow. The inlets and the shower outlet incorporate approved check valve cartridges, however, the complete products have not been fully tested to demonstrate they provide backflow protection. Maximum working pressure 10.0 Bar. Maximum operating temperature 60°C.
Range of wafer and lug type butterfly valves incorporating blue epoxy coated ductile iron bodies, either stainless steel (SS316/SS304) or epoxy coated ductile iron discs and EPDM seat. The valves are either handwheel and gear operated (Models D371X and DL371X) or lever operated (Models D71X and DL71X). Maximum working pressure 16.0 bar Maximum operating temperature 85°C.
Range of wafer and lug type butterfly valves incorporating blue epoxy coated ductile iron bodies, either stainless steel (SS316/SS304) or epoxy coated ductile iron discs and EPDM seat. The valves are either handwheel and gear operated (Models SD-BVG16 and SD-16BVLL) or lever operated (Models SD-BVL125 and SD-16BVGL). Maximum working pressure 16.0 bar Maximum operating temperature 85°C.
Range of wall mounted, concealed, 2-way diverter valve (brass body and chrome trim set) with a single lever operating member (RAKPER3020-2C) or cubed type operating member (RAKPES3020-2C). Maximum working pressure 10.0 Bar Maximum operating temperature 85.0°C
Range of wall mounted concealed diverter valves with a plastic body. The flow is controlled to two outlets via solenoid valves. Maximum working pressure 5.0 Bar. Maximum working temperature 65°C
Range of pilot operated, adjustable, pressure reducing control valves, incorporating stainless steel bodies & strainers and EPDM ‘O’ rings & diaphragm. Auxiliary components include stainless steel tubing and isolation valves. The product is available with the following adjustable outlet pressures: 0 - 3.0 bar (silver spring), 1.0 - 8.0 bar (black spring), 1.0 - 16.0 bar (red spring). Maximum supply pressure 16.0 bar. Maximum operating temperature 65°C.
Pressure relief valve with a plastic body and EPDM diaphragm with manual easing gear. Pre-set at 3.0 bar. Model 31030030 is pre-set at 2.5 bar. Model 31030070 is pre-set at 4.5 bar. Maximum operating temperature 90°C.
Range of latching and non-latching solenoid valves with a plastic body (all models, except for 07230017 & 07230018 models added September 2023) and an EPDM diaphragm. The inlet incorporates a stainless-steel strainer. Maximum working pressure 8.0 bar. Maximum operating temperature 65°C.
Range of ball valves with nickel plated brass bodies, chrome plated brass ball, PTFE seats, and either lever or T handle operating members (see models). Maximum working pressure 16.0 to 64.0 Bar (Size & model dependant, see models) Maximum working temp 85°C
Range of spherical valves with nickel plated brass bodies, chromium plated brass balls, PTFE seals, NBR and/or FKM ‘O’-rings. 140, 140M, 141 & 141M series models incorporate a stainless-steel strainer. 140 & 141 series models also incorporate a magnet. The 121 & 122 series models are 3-way valves. Maximum working pressure: See PN in brackets under model. Maximum operating temperature: Cold water use only.
Range of spherical valves with nickel plated brass bodies, chromium plated brass balls, PTFE seals, NBR and/or FKM ‘O’-rings. 140, 140M, 141 & 141M series models incorporate a stainless-steel strainer. 140 & 141 series models also incorporate a magnet. The 121 & 122 series models are 3-way valves. Maximum working pressure: See PN in brackets under model. Maximum operating temperature: Cold water use only.
Range of gate valves with blue epoxy coated ductile iron bodies, incorporating an EDPM wedge and non-rising spindle with hand wheel operating member. Maximum working pressure 10.0 bar. Maximum working temperature 65°C
Resilient seated gate valves with blue epoxy coated ductile iron bodies, and an EPDM wedge, gasket and ‘O’-ring. With a non-rising spindle, and handwheel operating member. Maximum working pressure 25.0 bar. Maximum operating temperature 85°C.
Range of lock shield or handwheel operated gate valves with brass bodies, gate & PTFE seals, for use with copper tube manufactured to EN1057. Maximum working pressure 16.0 bar. Maximum operating temperature 85°C.
Range of in-line screw-down stop valves with brass bodies, incorporating rising spindle headworks and EPDM washers. For use with BS EN 1057 copper pipe. Maximum working pressure 16 Bar at 30°C, 5 Bar at 99°C
Page 10 of 46
We use cookies to give you the best possible experience with WRAS. Some are essential to provide website functions and ensure the website is secure. We also use cookies to help us understand how people use the site and to make improvements. Click "Accept All" to enable recommended settings or click "Manage cookies" to adjust your settings. For more details, see our Cookie Policy.