Range of three hole, single outlet (fixed) combination tap assemblies (chromium plated brass) incorporating quarter turn ceramic disc headworks with single lever operating. The spout outlet incorporates an aerator or a flow straightener. Product supplied with stainless steel braided EPDM lined flexible connection hoses. Maximum working pressure 3.5 Bar. Maximum operating temperature 60°C.
Range of horizontal or vertical expansion vessels with an EPDM membrane. Maximum working pressure 10.0 or 16.0 bar (please refer to model). Maximum operating temperature 100°C.
Filling link assembly with a nylon body and EPDM ‘O’-rings. The product incorporates a screwdriver operated shut off valve and two check valve cartridges, verified by test (suitable for backflow protection against Fluid Category 3). The product is also supplied with two screwdriver operated angled spherical valves and a mounting bracket. Maximum working pressure 10.0 bar. Cold water use only.
A range of water filter cartridges with polypropylene bodies. Maximum working pressure 8.6 bar. Cold water use only.
Tigris K5 (PPSU - plastic body) and M5 (DZR brass body) ranges of press-fit (U, H, TH crimp profiles) fittings with stainless steel crimp sleeves and EPDM ‘O’-rings, for use with Tigris K1 multi-layer PEX-c/AL/PE-HD pipe. Maximum working pressure 6.0 bar. Maximum operating temperature 95°C.
Wavin range of Tigris K1 (plastic bodies) and M1 (brass bodies) press-fit fittings for use with Tigris PEX/AL/PE HD (50mm & 63mm) and Tigris PERT/AL/PERT WT (75mm) barrier pipes. Maximum working pressure 6.0 bar. Maximum operating temperature 95°C.
Range of solder ring copper fittings for use with copper tube to EN 1057. The HLSRDPMFWT and HLSRDPMFZT models incorporate a captive nut on one end with a fibre gasket washer. Maximum working pressure 16.0 bar. Maximum operating temperature 85°C.
Range of solder ring brass fittings for use with copper tube (manufactured to EN 1057). The HLSR20CB-d tank connector incorporates an EPDM washer. Maximum working pressure 16.0 bar. Maximum operating temperature 85°C.
Range of solder ring copper fittings for use with copper tube to EN 1057. Maximum working pressure 16.0 bar. Maximum operating temperature 85°C.
Range of brass compression fittings incorporating brass ring olive to be used with pipe manufactured to EN ISO 15875. Maximum working pressure 8.0 bar. Maximum operating temperature 90°C.
The 3G Metric Imperial range of plastic compression fittings with polypropylene bodies, compression nut and silicone seal for use with PE80 pipe (manufactured to BS EN 12201). Maximum working pressure: Fittings when used with PE100 pipe = 16.0 bar. Fittings when used with PE80 pipe = 12.0 bar. For above and below ground and cold water use only.
>B< Press range of stainless-steel SUS316L fittings for use with 316L stainless steel tube manufactured to EN10312. For above and below ground use. Maximum working pressure 16.0 bar. Maximum operating temperature 85°C.
‘Tectite Sprint’ range of pushfit fittings with copper or DZR brass bodies. 10mm, 15mm, 22mm & 28mm pushfit fittings are for use with copper pipe (manufactured to BS EN 1057) and polybutylene barrier pipe and cross linked PEX barrier pipe (manufactured to BS 7291). 35mm, 42mm & 54mm pushfit fittings are for use with copper pipe (manufactured to BS EN 1057) only. When used with PB & PEX pipes operating parameter are: 12.0 bar@cold water. 3.0 bar@92°C. When used with copper pipes operating parameter are: 20.0 bar@cold water. 10.0 bar@100°C.
Range of M type press fittings with TP2 copper bodies and EPDM ‘O’-rings, for use with TP2 copper pipe to EN1057. Above ground use only. Maximum working pressure 16.0 bar. Maximum operating temperature 85°C.
Range of ‘StrengThin™’ 100 System couplings and fittings for use with stainless steel pipe (manufactured to EN 10217-7). For above and below ground use. Maximum working pressure 16.0 bar. Maximum operating temperature 65°C.
Kuterlite K900 Pro range of compression fittings with DZR brass bodies for use with copper pipe (EN 1254) Maximum working pressure for 8mm-10mm = 70.0 bar. Maximum working pressure for 12mm – 28mm = 20.0 bar. Maximum working pressure for 35mm – 54mm = 6.0 bar. Maximum operating temperature 90°C.
Range of end feed brass fittings for use with copper tube (manufactured to EN 1057). The HLE20CB-d tank connector incorporates an EPDM washer. Maximum working pressure 16.0 bar. Maximum operating temperature 85°C.
Range of end feed copper fittings for use with copper tube to EN 1057. The HLDPMFWT and HLDPMFZT models incorporate a captive nut on one end with a fibre gasket washer. Maximum working pressure 16.0 bar. Maximum operating temperature 85°C.
Range of end feed copper or gunmetal solder fittings for use with copper pipe. Maximum working pressure 16.0 bar (Sizes 8 - 28mm). Maximum working pressure 10.0 bar (Sizes 35 - 108mm). Maximum operating temperature 100°C.
Range of dual flush, WC outlet valves. CJ305 is operated via a push button assembly or with battery powered infra red sensor. CJ302 is controlled with a push button assembly for either full or reduced flush and both models incorporate an internal overflow. Cold water use only.
‘POD’ range of indirect and direct heat interface units providing space heating and instantaneous hot water. The heat transfer is generated via plate heat exchangers. The domestic hot water (DHW) circuit incorporates an adjustable temperature mixing valve. The indirect models incorporate an expansion vessel (on the CW inlet of the DHW circuit) and a pressure relief valve set at 3.0 bar (on the space heating circuit). The indirect models only are supplied with a temporary filling loop, which comprises of a stainless steel braided EPDM lined flexible hose assembly and a lever operated spherical valve for connection to the primary circuit. The angled cold water inlet incorporates an isolation valve and a branch to connect to the filling loop, which includes a double check valve assembly (verified by test, suitable for backflow protection against Fluid Category 3). Maximum working pressure for indirect units: Primary circuit: 16.0 bar. Space heating: 2.5 bar. Secondary circuit (DHW): 10.0 bar. Maximum working pressure for direct units: Primary circuit: 10.0 bar. Space heating: 10.0 bar. Secondary circuit (DHW): 10.0 bar. Maximum operating temperature for domestic hot water 65°C. Maximum operating temperature for central heating and primary circuit 85°C.
Range of stainless-steel plate heat exchangers. Maximum operating pressures - primary circuit: 3.0 bar, secondary circuit (DHW): 10.0.bar. Maximum working temperature 80°C.
Under counter electric instantaneous water heater with a stainless steel tank. The flow is controlled via a solenoid valve. The product is supplied with a 3 way isolation valve (15mm compression x 15mm compression x ¾” BSP (M)), as well as a filter head and filter cartridge for installation prior to the under counter unit. LLDPE tubing and pushfit connections are provided for connecting between these items. The filter head inlet incorporates an approved check valve cartridge, however, the complete product has not been fully tested to demonstrate it provides backflow protection. The inlet to the under counter unit incorporates a combined silicone washer and stainless steel strainer and an approved check valve cartridge, however, the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum working pressure 5.5 bar. Maximum operating temperature 98˚C. Cold water supply only.
Range of wall mounted, gas-fired, condensing combination boilers providing domestic hot water via a plate heat exchanger. The pressurised central heating system incorporates an expansion vessel and a pressure relief valve set at 3.0 bar. The inlets to the domestic hot water and primary circuits each have a screwdriver operated angled spherical valve. Both include a ½” BSP (M) connection for a filling link. The Greenstar CDi models only are supplied with an integral charging link (CAB device) verified by test (suitable for backflow protection against Fluid Category 3). Maximum working pressure of the primary circuit is 2.5 bar. Maximum working pressure of the secondary circuit is 10.0 bar. Maximum operating temperature of primary circuit is 82°C. Maximum operating temperature of secondary circuit is 60°C.
Range of electric combination boilers providing heating and instantaneous hot water. The heating system incorporates an expansion vessel and pressure relief valve (set at 3.0 bar). The DHW inlet and outlet incorporate spherical servicing valves. Fittited with a CAB device keyless filling link, verifired by test, suitable for category 3 backlfow protection. Maximum working pressure on central heating circuit 2.5 bar & Domestic Hot Water 10bar. Maximum operating temperature 80°C


Hydraulic block assembly comprising of a flow regulator, central heating pump assembly and a stainless-steel plate heat exchanger. Maximum working pressures: DHW circuit: 10.0 Bar Central heating circuit: 2.5 Bar Maximum operating temperature: DHW Circuit: 65.0°C Central heating circuit: 90.0°C
Hydraulic block incorporating heat exchangers with pressed stainless-steel plate bodies and copper brazing. Product also incorporates primary and secondary water way with PPS plastic fittings and adaptors and a flow adjustment valve. Maximum operating temperature: Central Heating Circuit: 90°C, Direct Hot Water Circuit: 65°C. Maximum working pressure: Central Heating Circuit: 2.5 bar, Direct Hot Water Circuit: 10 bar.
Range of commercial ice making machines with flow controlled via solenoid valve. Maximum working pressure 8 bar. Cold water use.
Range of pressure transmitters with stainless steel bodies. Maximum working pressure 10.0 to 200.0 bar (please refer to model). Maximum operating temperature 100°C.
Spout end flow control device (aerator with ‘switchable’ spray formation). Maximum operating temperature 65°C.
Range of multistage pumps with brass suction and discharge bodies, stainless steel housing, shaft and impeller, and EPDM ‘O’-rings and seals. Maximum working pressure: 6.0 bar (46553 - Stuart CH 4-30 & 46554 - Stuart CH 4-40 models) or 9.0 bar (46555 - Stuart CH 4-50 &46556 - Stuart CH 4-60 models). Maximum operating temperature 65°C.
Range of booster pumps with stainless steel bodies, plastic impellers, and NBR ‘O’-rings. The products incorporate a temperature sensor, pressure sensor and a pressure vessel. The CSBPXXX-XX-A models incorporate a non-return valve integral to the pump chamber. The CSBPXXX-XX-B(-N) models added January 2026 incorporate a non-return valve on the inlet and outlet port. Maximum working pressure 6.5 bar. Maximum operating temperature 75°C.
Range of booster pumps with stainless steel bodies, plastic impellers, and NBR ‘O’-rings. The products incorporate a temperature sensor, pressure sensor, pressure vessel and a non-return valve integral to the pump chamber. Maximum working pressure 6.5 bar. Maximum operating temperature 75°C.
Range of vertical multistage pumps with stainless-steel bodies, stainless-steel impellers, shaft and outer sleeve. Maximum working pressures: T (oval flange): 16.0 bar. V (Victaullic & grooved), C (clamp flanges) & F (round flange) versions: 26.0 bar. Maximum operating temperature 100°C.
Range of vertical multistage booster pumps, with stainless steel bodies and impellors. Maximum working pressure is either 16.0 or 25.0 bar depending on specific model. Maximum operating temperature 85°C.
Range of vertical multistage pumps with stainless-steel bodies, stainless-steel impellers, shaft and outer sleeve. Maximum working pressures: T (oval flange): 16.0 bar. V (Victaullic & grooved), C (clamp flanges) & F (round flange) versions: 26.0 bar. Maximum operating temperature 100°C.
Range of horizontal self-priming multistage pumps with stainless steel bodies, stainless steel impellers, shaft and outer sleeve. Maximum working pressure 10.0 Bar Maximum operating temperatures: EH Three phase models 85°C, EH Single phase models 55.0°C and EHsp models 35°C.
‘3ME’ Range of horizontal pumps with stainless steel bodies and impellers, and EPDM ‘O’-rings. The products are supplied with a carbon/ceramic/EPDM shaft seal. Maximum working pressure 10.0 bar. Maximum operating temperature 100°C.
Ranges of overhead shower outlets with brass bodies, chrome plated plastic shower handsets, shower sets and shower kits. The shower sets comprise of a chrome plated plastic shower handset and shower hose. The shower kits comprise of a chrome plated plastic shower handset, brass wall elbow and either stainless steel interlocked, or PVC coated, shower hoses. The inlets of the shower handsets incorporate a plastic flow regulator at the inlet. Shower kits with ½” (M) inlets are also supplied with a brass wall elbow which incorporate a plastic flow regulator and an approved single check valve cartridge (however, the complete product has not been fully tested to demonstrate it provides backflow protection). Maximum operating temperature 60°C.
Range of shower handsets with plastic bodies incorporating an integral filters. The inlet incorporates a combined washer and a strainer, plastic flow regulator and an approved check valve cartridge, however, the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum operating temperature 60°C
Wall mounted overhead shower outlets with (chrome plated) brass bodies and EPDM ‘O’-rings. Maximum operating temperature 65°C.
Range of shower arms, ceiling arms, water intakes and wall mounted outlet brackets (all models excluding INOX are chrome plated brass, INOX models are stainless steel). Maximum operating temperature 60.0°C
Range of shower outlets: swivel ball joint overhead shower heads with brass bodies (chrome plated) and shower handsets with plastic bodies (chrome plated). The overhead showers incorporate a combined EPDM washer and stainless-steel strainer on the inlet. Maximum operating temperature 65°C.
Shower kit comprising of a brass bodied wall outlet elbow (chrome plated), TPE lined shower hose (chrome finish) and a brass bodied (chrome plated) shower handset with silicone nozzles. The wall outlet incorporates an approved check valve cartridge, however the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum operating temperature 60°C.
Range of shower outlets with plastic bodies (various finishes) incorporating a stainless-steel strainer and a flow regulator. Maximum operating temperature 60°C.
Range of showers handsets incorporating plastic bodies (chrome plated) Maximum operating temperature 60°C.
Range of shower outlets with plastic bodies (various finishes), incorporating EPDM o rings and stainless-steel strainers on the inlets. Models (24130xxx & 24132xxx) are overhead showers and model (24139xx0) is a wall mounted shower outlet. Model 24132xxx incorporates a flow restrictor on the inlet.
Non-metallic materials and components comply with BS6920 at 60°C
Range of shower arms, ceiling arms, water intakes and wall mounted outlet brackets with either chrome plated brass or stainless steel). Maximum operating temperature 60.0°C
Range of shower heads, shower handsets and shower kits incorporating either brass or plastic bodies (various finishes). The inlets of the shower handsets incorporate a stainless-steel strainer. Models ORA-MFSRKWOP-RO-CP, NEB-MFSRKWO-RO-CP & EVO-MFSRKWO-CP are supplied with a shower hose and riser rail. Maximum operating temperature 60°C.
Range of pillar taps (chrome plated brass) incorporating quarter turn ceramic disc headworks with cross-top operating members. The product is supplied with metal backnuts. Maximum working pressure 10.0 bar. Maximum operating temperature 65°C.
Page 7 of 46
We use cookies to give you the best possible experience with WRAS. Some are essential to provide website functions and ensure the website is secure. We also use cookies to help us understand how people use the site and to make improvements. Click "Accept All" to enable recommended settings or click "Manage cookies" to adjust your settings. For more details, see our Cookie Policy.