Range of single hole, single outlet (swivel) combination tap assemblies (various finishes). Incorporating a ceramic cartridge headwork with a single lever operating member. The spout outlet incorporates a plastic aerator. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.
Wall mounted, concealed, two-hole, single outlet fixed combination tap assembly (chrome plated brass) body incorporating a ceramic cartridge head work with a single lever operating member. The spout outlet incorporates a plastic aerator. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.
Wall mounted, concealed two-hole, single outlet fixed combination tap assembly (chrome plated brass) body incorporating a ceramic cartridge headwork with a single lever operating member. The spout outlet incorporates a plastic flow straightener. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.
Range of two hole, single outlet, (fixed) combination tap assemblies (chromium plated brass), incorporating a quarter turn ceramic disc headwork with single lever operating members. The spout outlets incorporate a plastic flow straightener and the products are supplied with metal backnuts. Maximum working pressure 10.0 bar. Maximum operating temperature 85°C.
Range of two hole, single outlet, (fixed) combination tap assemblies (chromium plated brass), With a quarter turn ceramic disc headwork with single lever operating members. Models M4306, M4306E & M4306F incorporate a non rising spindle headwork with dome type operating members. Model M4306G incorporate a non rising spindle headwork with cross top operating members. The spout outlets incorporate a plastic flow straightener and the products are supplied with metal backnuts. . Maximum working pressure 10.0 bar. Maximum operating temperature 85°C.
Range of two-hole, single outlet (fixed) combination tap assemblies (chromium plated brass) incorporating quarter turn ceramic disc headworks with cubed or dome operating members. The spout outlet incorporates a plastic flow straightener. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.
Wall mounted two-hole, metal, single outlet, fixed combination tap assembly (chromium plated brass), with a quarter turn ceramic disc headwork controlling the flow with a dome operating member. The temperature is controlled independently via a thermostatic cartridge with a dome operating member incorporating a manual override button. The spout incorporates a plastic flow straightener. Both inlets incorporate stainless steel strainer and an approved check valve cartridge, however, the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum operating pressure 5.0 bar. Maximum operating temperature 60° C
Range of wall mounted two-hole, metal, single outlet (fixed) combination tap assemblies (chromium plated brass), incorporating a ceramic disc diverter headwork controlling the flow between the spout outlet and the shower outlet with a dome type operating member. Temperature is controlled independently via a thermostatic cartridge with dome type operating members that incorporates a manual override button. The spout outlet incorporates a plastic aerator. Each inlet incorporates a stainless-steel strainer and an approved check valve cartridge, however, the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum working pressure 10.0 Bar Maximum operating temperature 60°C
Range of two hole, single outlet (fixed) combination tap assemblies (chromium plated brass). Model 805777 incorporate a non-rising spindle headwork with dome type operating members. Model 805783 incorporate a quarter turn ceramic disc headwork with single lever operating members. The fitting incorporates a manual diverter to the shower outlet The spout outlet incorporates a plastic flow straightener and the products are supplied with a shower hose, shower handset and metal backnuts. Maximum working pressure 10.0 bar. Maximum operating temperature 70°C.
Range of deck mounted, two hole, single outlet (fixed) combination tap assemblies with brass bodies (chrome plated). Incorporating quarter turn ceramic disc headworks, dome type operating members and self cancelling diverter to shower outlet. The temperature is controlled independently via a thermostatic cartridge with a dome type operating member that also incorporates a manual override button. Both inlets incorporate approved check valve cartridges, however, the complete product has not been fully tested to demonstrate it provides backflow protection. The spout outlet incorporates a plastic aerator. Models TL30024CP and TR30024CP are supplied with a shower riser rail, shower hose and shower handset. Maximum working pressure 5.0bar. Maximum operating temperature 60°C.
Range of wall mounted, two hole, single outlet (fixed) combination tap assemblies with brass bodies (chrome plated). Incorporating non-rising spindle headworks, dome type operating members and lockable, self cancelling diverter to shower outlet. The temperature is controlled independently via a thermostatic cartridge with a dome type operating member that also incorporates a manual override button. Both inlets incorporate stainless-steel strainer and approved check valve cartridges, however, the complete product has not been fully tested to demonstrate it provides backflow protection. The spout outlet incorporates a plastic aerator. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.
Wall mounted, two-hole, single outlet (swivel) combination tap assemblies (chromium plated brass), incorporating ceramic cartridge headwork with single lever operating members. The spout outlets incorporate a plastic aerator. Maximum working pressure 5.0 bar. Maximum operating temperature 65°C.
Range of wall mounted, two-hole, single outlet (fixed) combination tap assemblies (chromium plated brass) incorporating a lockable self-cancelling diverter to shower outlet. The flow is controlled by a quarter turn ceramic disc headwork with a dome operating member (model XB-SL-007 incorporates a manual override button) and the temperature is controlled independently via a thermostatic cartridge with a dome operating member and manual override button. Both inlets incorporate stainless-steel strainers and a single check valve cartridge (however, the complete product has not been fully tested to demonstrate it provides backflow protection). The spout outlet incorporates plastic aerator. Maximum working pressure 10 bar. Maximum operating temperature 60°C.
Range of wall mounted, three-hole, single outlet (fixed) combination tap assemblies (chromium plated brass). Incorporating quarter turn ceramic disc headworks and single lever operating members. The spout outlet incorporates a plastic aerator. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.
Range of wall mounted concealed, three-hole, single outlet (fixed) combination tap assemblies (brass body). Incorporating quarter turn ceramic disc headworks with dome or cube type operating members (see models). The spout outlet incorporates a plastic aerator. Maximum working pressure 10 bar. Maximum operating temperature 60°C.
Range of self closing shower column with brass body (chrome plated), incorporating a push button flow control and adjustable shower outlet. Maximum working pressure 8.0 bar. Cold water use only.
Range of five-hole, single outlet (fixed) combination tap assembly (chromium plated) brass bodies incorporating a quarter turn ceramic disc headworks to control the flow with single lever operating members. The product is supplied with stainless steel braided EPDM lined flexible interconnecting hose assemblies to connect between the valves and a lockable self-cancelling diverter that controls flow between spout and shower handset. The spout outlet incorporates a plastic flow straightener. The product is supplied with a shower hose and handset. Maximum working pressure 10 bar. Maximum operating temperature 65°C.
A range of spout outlets with PVC lined stainless steel interlocked tube covered by silica gel. Model WD-PVC-09-10 is a double outlet. Maximum working temperature 65°C.
Range of dosing pumps with plastic bodies. Models PM004 & PM005 have a maximum operating pressure of 6.0 bar. All other models have a maximum operating pressure of 10.0 bar. Cold water use only.
Filling link assembly with a nylon body and EPDM ‘O’-rings. The product incorporates a screwdriver operated shut off valve and two check valve cartridges, verified by test (suitable for backflow protection against Fluid Category 3). The product is also supplied with two screwdriver operated angled spherical valves and a mounting bracket. Maximum working pressure 10.0 bar. Cold water use only.
Filling loop assemblies comprising of a stainless steel braided, EPDM lined hose, double check valve assembly with isolation valve verified by test (suitable for backflow protection against fluid category 3) and either a straight or tee isolation valve. Maximum working pressure 10.0 bar. Maximum operating temperature 85ºC.
Uponor Uni Pipe PLUS system incorporating Uponor RTM metal and PPSU fittings for use with Uni Pipe PLUS PE-RT/AL/PE-RT pipes. Maximum operating pressure 10.0 bat at 70°C.
‘Numepress’ range of stainless-steel crimp fittings incorporating EPDM and ‘O’-rings. For use with stainless steel tube. Maximum working pressure 16.0 bar. Maximum operating temperature 95°C.
Range of DZR brass couplings incorporating EPDM ‘O’-rings for use with Uponor Ecoflex Aqua and Uponor Ecoflex VIP Aqua PE-Xa pipe. For above and below ground use. Maximum working pressure 10.0 bar. Maximum operating temperature 95°C.
Pexal range of brass press fittings with EPDM ‘O’-rings for use with copper pipe EN1057. Model VS0171373 incorporates 90° copper elbow (chrome plated) Maximum working pressure 10.0 bar. Maximum operating temperature 95°C.
>B< Press range of stainless-steel SUS316L fittings for use with 316L stainless steel tube manufactured to EN10312. For above and below ground use. Maximum working pressure 16.0 bar. Maximum operating temperature 85°C.
Range of dual flush, WC outlet valves. CJ305 is operated via a push button assembly or with battery powered infra red sensor. CJ302 is controlled with a push button assembly for either full or reduced flush and both models incorporate an internal overflow. Cold water use only.
Dual flush WC outlet valve with an ABS body, incorporating a silicone seal and internal overflow. The valve is operated via a push button assembly for either full or reduced flush. Cold water use only.
WC dual flush drop valve comprising of a plastic body, silicone seating washer and an internal overflow. The valve is operated via a push button assembly (not included) for either full or reduced flush. Cold water use only.
Range of plate heat exchanger with stainless steel bodies. Maximum working pressure10 bar. Maximum operating temperature 100°C.
‘POD’ range of indirect and direct heat interface units providing space heating and instantaneous hot water. The heat transfer is generated via plate heat exchangers. The domestic hot water (DHW) circuit incorporates an adjustable temperature mixing valve. The indirect models incorporate an expansion vessel (on the CW inlet of the DHW circuit) and a pressure relief valve set at 3.0 bar (on the space heating circuit). The indirect models only are supplied with a temporary filling loop, which comprises of a stainless steel braided EPDM lined flexible hose assembly and a lever operated spherical valve for connection to the primary circuit. The angled cold water inlet incorporates an isolation valve and a branch to connect to the filling loop, which includes a double check valve assembly (verified by test, suitable for backflow protection against Fluid Category 3). Maximum working pressure for indirect units: Primary circuit: 16.0 bar. Space heating: 2.5 bar. Secondary circuit (DHW): 10.0 bar. Maximum working pressure for direct units: Primary circuit: 10.0 bar. Space heating: 10.0 bar. Secondary circuit (DHW): 10.0 bar. Maximum operating temperature for domestic hot water 65°C. Maximum operating temperature for central heating and primary circuit 85°C.
Electric instantaneous, vented mains water heater with plastic a housing and silicon rubber hose. Maximum operating temperature 98°C.
Range of wall mounted, gas-fired, condensing combination boilers providing domestic hot water via a plate heat exchanger. The pressurised central heating system incorporates an expansion vessel and a pressure relief valve set at 3.0 bar. The inlets to the domestic hot water and primary circuits each have a screwdriver operated angled spherical valve. Both include a ½” BSP (M) connection for a filling link. The Greenstar CDi models only are supplied with an integral charging link (CAB device) verified by test (suitable for backflow protection against Fluid Category 3). Maximum working pressure of the primary circuit is 2.5 bar. Maximum working pressure of the secondary circuit is 10.0 bar. Maximum operating temperature of primary circuit is 82°C. Maximum operating temperature of secondary circuit is 60°C.
Range of commercial ice making machines with flow controlled via solenoid valve. Maximum working pressure 8 bar. Cold water use.
‘RSM’ range of ultrasonic water meters with blue epoxy coated ductile iron bodies, stainless steel transducer and EPDM ‘O’-rings. Maximum working pressure 16.0 bar. Maximum operating temperature 50°C.
Range of water meters with blue epoxy coated iron bodies and EPDM ‘O’-rings. Maximum working pressure 16.0 bar. Maximum operating temperature 85°C.
Range of pressure transmitters with stainless steel bodies. Maximum working pressure 10.0 to 200.0 bar (please refer to model). Maximum operating temperature 100°C.
Spout end flow control device (aerator with ‘switchable’ spray formation). Maximum operating temperature 65°C.
Range of brass (chrome plated) quick fit connectors. Maximum operating temperature 60°C
Range of brushless DC centrifugal pumps with a plastic body. Maximum working pressure 1.0 Bar. Maximum operating temperature 70°C.
Range of single and twin shower booster pumps with brass bodies, DZR brass impellers, NBR ‘O’-ring and EPDM seals. Maximum working pressure 6.0 bar. Maximum operating temperature 60°C.
Ranges of overhead shower outlets with brass bodies, chrome plated plastic shower handsets, shower sets and shower kits. The shower sets comprise of a chrome plated plastic shower handset and shower hose. The shower kits comprise of a chrome plated plastic shower handset, brass wall elbow and either stainless steel interlocked, or PVC coated, shower hoses. The inlets of the shower handsets incorporate a plastic flow regulator at the inlet. Shower kits with ½” (M) inlets are also supplied with a brass wall elbow which incorporate a plastic flow regulator and an approved single check valve cartridge (however, the complete product has not been fully tested to demonstrate it provides backflow protection). Maximum operating temperature 60°C.
Range of shower outlets (celing or wall mounted arms - see model) with chrome plated brass bodies and silicone nozzles. The products incorporate a swivel joint connection to the shower head which incorporates a combined NBR washer and stainless steel strainer. All models, except for the 15199 model, include a plastic flow regulator on the inlet to the shower head. Maximum operating temperature 60°C.
Range of overhead shower outlets with brass bodies (various finishes, see model), incorporating stainless steel strainer and flow regulator on the inlets. Maximum operating temperature 60°C.
Range of shower handsets with plastic bodies incorporating an integral filters. The inlet incorporates a combined washer and a strainer, plastic flow regulator and an approved check valve cartridge, however, the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum operating temperature 60°C
Range of shower arms, ceiling arms, water intakes and wall mounted outlet brackets (all models excluding INOX are chrome plated brass, INOX models are stainless steel). Maximum operating temperature 60.0°C
Range of Y type strainers with blue epoxy coated ductile iron bodies and EPDM ‘O’-rings. Maximum working pressure 25.0 bar. Maximum operating temperature 85°C
Range of wall mounted hose union taps (brass body or DZR brass body - see model) incorporating a non-rising spindle headwork with a ‘T’-type operating member. The 1BCB001 & 1BCB701 models incorporate two approved single check valve cartridges, however the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum working pressure 14.0 Bar. Maximum operating temperature 85°C.
Range of pillar taps (chrome plated) brass bodies with quarter turn ceramic disc headworks and single lever type operating members. The spout outlet incorporates a plastic flow straightener. The products are supplied with metal backnuts. Maximum working pressure 10.0 bar. Maximum operating temperature 65°C.
Range of pillar taps with brass bodies (various finishes) incorporating non-rising spindle headworks using either dome type or cross top operating members. Spout outlets incorporate plastic flow straighteners. The products are also supplied with metal back nuts. Maximum working pressure 10.0 Bar. Maximum operating temperature 85°C.
Page 48 of 204
We use cookies to give you the best possible experience with WRAS. Some are essential to provide website functions and ensure the website is secure. We also use cookies to help us understand how people use the site and to make improvements. Click "Accept All" to enable recommended settings or click "Manage cookies" to adjust your settings. For more details, see our Cookie Policy.