Range of wall mounted spout outlets with a chromium plated brass bodies and NBR ‘O’-rings. The outlets incorporate a plastic aerator. Maximum operating temperature 85°C.
Range of expansion vessels with EPDM membrane and stainless steel flange connections. Maximum working pressure of 10.0 bar. Maximum operating temperature 100°C.
Filling loop assemblies consisting of a brass bodied spherical valve, stainless steel braided EPDM lined flexible hose (051603F-BAGR4 model) or copper pipe (0516-ATAGBAG model) and a combined double check valve assembly incorporating a spherical valve with a DZR brass body, verified by test (suitable for backflow protection against Fluid Category 3). Maximum working pressure 10.0 bar. Maximum operating temperature 60°C
Filling loop assemblies comprising of a stainless steel braided, EPDM lined hose, double check valve assembly with isolation valve verified by test (suitable for backflow protection against fluid category 3) and either a straight or tee isolation valve. Maximum working pressure 10.0 bar. Maximum operating temperature 85ºC.
>B< Range of copper push-fit fittings for use with copper tube manufactured to EN 10226-1. Maximum working pressure 16.0 bar. Maximum operating temperature 85°C.
‘Unidelta Deltapress’ range of brass press-fit fittings for use with ‘Unidelta Flexall’ PE-RT/AL/PE-RT pipe. Maximum working pressure 10.0 bar. Maximum operating temperature 95°C.
Range of brass, chrome plated brass or DZR brass compression fittings for use with copper pipe only. Maximum working pressure 16.0 bar. Maximum operating temperature 85°C.
Range of PVC-u solvent weld and threaded union fittings incorporating an EPDM ‘O’-ring. For use with PVC-u pipe manufactured to ISO 1452 and DIN 8063. Maximum working pressure 10.0 bar. Cold water use only.
‘Xpress’ range of press fit fittings with copper or brass bodies and EPDM ‘O’-rings. For use with copper tube manufactured to EN1057. For above ground ground use only. Maximum working pressure 16.0 bar. Maximum operating temperature 100°C.
‘Endex’ range of copper alloy and copper end feed fittings for use with copper pipe. For above ground use only. Maximum working pressure 16.0 bar. Maximum operating temperature 99°C.
Center Brand range of brass and copper end feed fittings for use with copper pipe. For above ground use only. Maximum working pressure 16.0 bar. Maximum operating temperature 99°C.
Single low-level horizontal mount float switch with stainless-steel body and float. Maximum operating temperature 100°C.
Range of WC pressure flushing valves with a solenoid valve controlling the flow. The valves are operated via an infra-red sensor or push-button assembly. The solenoid valve also incorporates a lever operated isolation valve. Maximum working pressure – 5.0 Bar. Cold water use only
Range of stainless-steel plate heat exchangers with EPDM gaskets. The primary circuit, (excluding the E2 prefix models), incorporates a drain valve and a pump (excluding STP prefix models including an ‘N’ as the 14th figure). Operating parameters: Maximum working pressure of the secondary circuit: 6.0 bar or 10.0 bar (see model). Maximum working pressure of the primary circuit: E4 models: 6.0 bar. C3, E3, E2, i2: 10.0 bar. Models added February 2023 – Econoplate STP3, STC3, STP2, STC2 & STP4: 10.0 bar. Maximum operating temperature: Primary 140°C & Secondary 85°C.
Domestic hot water heat recovery unit incorporating a stainless-steel plate heat exchanger and cylinder. Maximum working pressure 3.0 bar. Maximum operating temperature 60°C.
Range of under-sink, electrically heated vented water heaters (cased and insulated). Maximum operating temperature 98˚C
Greenstar Heatslave II range of floor standing oil-fired condensing combination boilers providing domestic hot water via a plate heat exchanger and pressurised central heating system, which incorporates an expansion vessel and pressure relief valve set at 3.0 bar. The cold water inlet incorporates a screwdriver operated spherical valve followed by a plastic flow regulator inserted within the pipework. Maximum working pressure: Primary circuit 2.5 bar. Secondary circuit 10.0 bar. Maximum operating temperature 82°C.
"Greenstar" range of indirect heat interface units and "Flow 8000" (added December 2024) range of direct heat interface units providing heating and instantaneous hot water. The heating system incorporates an expansion vessel. The products are sold with or without a prefix kit (see model), which comprises of a mounting bracket that includes spherical valves for all circuits. The "Greenstar" indirect models include a pressure relief valve (set at 3.0 bar) on the space (central) heating circuit. Greenstar models: Maximum working pressure district heating 10.0 bar. Maximum working pressure space heating 2.5 bar. Maximum working pressure secondary hot water 10.0 bar. Maximum operating temperature 60°C (secondary) and 90°C (primary). Flow 8000 models (added December 2024): Maximum working pressure district and space heating 10.0 bar. Maximum working pressure secondary hot water 10.0 bar. Maximum operating temperature 60°C (secondary) and 90°C (primary).
Range of in-line water meters with brass bodies and plastic inlet filters. Maximum working pressure 16.0 bar. Maximum operating temperature 50°C (SJ & ELECTO-SJ models) Maximum operating temperature 30°C (AP VARIO and AP RADIO models)
Water meter with a DZR brass body, stainless steel temperature sensors and EPDM ‘O’-rings. The inlet incorporates a plastic strainer. Maximum working pressure 16.0 bar. Maximum operating temperature 85°C.
Range of water meter manifolds (plastic body). Model WB31520CG incorporates a single check valve cartridge and model WB31520CGDCV two single check valve cartridges, however, the complete product has not been fully tested to demonstrate it provides backflow protection Maximum working pressure 16.0 bar. Cold water use only.
‘EVE Whole house’ twin impeller booster pump with a plastic body and impellers and EPDM ‘O’-rings. The inlet and outlet hoses incorporate a screwdriver operated isolation valve. The pump body outlets incorporate a non-return valve. The product is supplied with two loose combined EPDM and stainless steel inlet washers and two loose EPDM outlet washers. Maximum working pressure 3.0 bar. Maximum operating temperature 65°C.
‘ECOCIRC XL N’ & ‘ECOCIRC XL PLUS N’ range of circulation pumps with stainless steel bodies, plastic impellers, and EPDM ‘O’-rings. Maximum working pressure 10.0 bar. Maximum operating temperature 85°C.
Range of vertical multistage pumps with stainless-steel bodies, stainless-steel impellers, shaft and outer sleeve. Maximum working pressures: T (oval flange): 16.0 bar. V (Victaullic & grooved), C (clamp flanges) & F (round flange) versions: 26.0 bar. Maximum operating temperature 100°C.
Range of multistage pumps with brass suction and discharge bodies, stainless steel housing, shaft and impeller, and EPDM ‘O’-rings and seals. Maximum working pressure: 6.0 bar (41491 & 41492 models) or 9.0 bar (41493 & 41494 models). Maximum operating temperature 65°C.
Wall mounted shower head and arm (chromium plated brass) incorporating a NBR seal and TPE gasket. The inlet to the shower head from the shower arm incorporates a stainless-steel strainer and an approved check valve cartridge, however, the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum working temperature 60°C.
Range of shower handsets and shower kits. Shower kits 2.1703.391, 2.1703.015 & 2.1703.016 incorporate a shower handset, shower hose and riser rail. Shower handset inlets incorporate a flow regulator. Maximum operating temperature 60°C.
Range of shower outlets incorporating brass bodies (various finishes) and NBR ‘O’-rings. Maximum operating temperature 85°C.
Range of shower outlets and shower kits. Shower outlets consisting of wall and ceiling mounted shower heads and hand shower. The inlets incorporate stainless steel flow regulators and approved check valve cartridges, however, the complete product has not been fully tested to demonstrate it provides backflow protection. The shower kits can consist of shower hose, shower handset, riser rail and wall outlet elbow with bracket (depending on model). Shower handset inlet incorporates a stainless-steel strainer. Both the outlet of the wall elbow and inlet of shower handset incorporates an approved check valve cartridge, however, the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum operating temperature 60°C.
Range of filter type fixed ‘shower’ outlets and shower handsets with plastic bodies. Maximum operating temperature 45°C.
Range of filter type fixed ‘shower’ outlets and shower handsets with plastic bodies. Maximum operating temperature 45°C.
Range of shower outlets incorporating brass bodies (various finishes) and NBR ‘O’-rings. Maximum operating temperature 85°C.
Shower outlet incorporating brass body (gold effect finish), incorporating a flow regulator and EPDM O-rings. Maximum operating temperature 60ºC.
Shower head with a brass body (various finishes), incorporating EPDM O- rings and a stainless-steel strainer at the inlet. Maximum operating temperature 60.0°C
Shower handset incorporating a chrome plated plastic body and EPDM ‘O’-rings. Maximum operating temperature 60°C.
Range of Y type strainers with blue epoxy coated ductile iron bodies and EPDM ‘O’-rings. Maximum working pressure 25.0 bar. Maximum operating temperature 85°C
Range of in-line `Y` patterned strainers with bronze bodies and stainless-steel strainer. Maximum working pressure 16.0 bar. Maximum operating temperature 100°C. Closed circuit up to 110°C
Range of pillar taps with brass bodies (various finishes) incorporating non-rising spindle headworks using either dome type or cross top operating members. Spout outlets incorporate plastic flow straighteners. The products are also supplied with metal back nuts. Maximum working pressure 10.0 Bar. Maximum operating temperature 85°C.
Range of deck mounted self-closing pillar taps (chromium plated brass), incorporating a spring-loaded headwork with a dome type operating member. The spout outlet incorporates a plastic flow straightener. During January and February 2022, the products are supplied with metal back nuts. From March 2022, the products are supplied with plastic backnuts. Maximum working pressure 10.0 bar. Maximum working temperature 60°C.
Range of TPE lined flexible shower hoses incorporating a conical nut. Maximum operating temperature 60°C.
Range of plastic shower hoses (chrome effect finish) incorporating a PVC inner liner, with EPDM ‘O’-rings and/or washers. Models H3DN6-XXX101C and H3DV2-XXX101A incorporate stainless steel strainers. Maximum operating temperature 60°C.
Range of TPE and TPS lined flexible hose assemblies incorporating NBR ‘O’-rings and various end connections. Maximum operating temperature 60°C.
Range of PET (Polyethylene terephthalate) braided flexible hoses incorporating PEX liner and EPDM ‘O’-rings. Maximum working pressure 5.0 bar. (10.0 bar for models added September 2025). Maximum operating temperature 70°C.
Range of plastic shower hoses (chrome effect finish) incorporating a PVC inner liner, with EPDM ‘O’-rings and/or washers. Maximum operating temperature 60°C.
Range of stainless steel braided HDPE lined flexible hose assemblies incorporating EPDM ‘O’-rings and/or washers depending on end connection. Maximum working pressure 10.0 bar. Maximum operating temperature 85°C
Range of stainless-steel braided EPDM lined flexible hose assemblies with various end connections. SCFA models incorporate a spherical valve. Maximum working pressure 16.0 bar. Maximum operating temperature 85°C.
A range of wall mounted self-closing shower valves (chromium plated brass), incorporating a spring loaded headwork with a dome type operating member. Model TF222CP250 is supplied with metal back nut. Maximum working pressure 10.0 bar. Maximum working temperature 60°C.
Range of thermostatic blending valves with brass bodies, EPDM ‘O’-rings and chromium plated dome type operating members. The inlets incorporate plastic strainers and approved check valve cartridges, however, the complete product has not been fully tested to demonstrate it provides backflow protection Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.
Range of wall mounted, thermostatic shower blending valves, with a brass body (various finishes - see model), incorporating a thermostatic cartridge controlling the temperature with various operating members (see model). Both inlets incorporate a combined EPDM washer with a stainless steel strainer and an approved single check valve cartridge, however, the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum working pressure 5.0 bar. Maximum operating temperature 65°C.
Wall mounted, bar type thermostatic shower mixer (chromium plated brass), incorporating a quarter turn ceramic disc headwork controlling the flow with a dome operating member. The temperature is controlled independently via a thermostatic cartridge with a dome operating member. The outlet incorporates a single check valve cartridge assembly; however, the complete product has not been fully tested to demonstrate it provides backflow protection. The inlet connections incorporate an eccentric isolation valve and flow regulator. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.
Page 37 of 171
We use cookies to give you the best possible experience with WRAS. Some are essential to provide website functions and ensure the website is secure. We also use cookies to help us understand how people use the site and to make improvements. Click "Accept All" to enable recommended settings or click "Manage cookies" to adjust your settings. For more details, see our Cookie Policy.