Non- verifiable double check valve assembly consisting of two spring loaded resilient trim in-line check valve cartridges housed in a chrome plated DZR brass body with an integral insolation valve between the cartridges. For use with copper pipes to EN1057. Maximum working pressure 10.0 bar. Maximum operating temperature 85°C.
Range of double check valve assemblies consisting of two spring loaded resilient trim in-line check valve cartridges housed in a DZR brass body (chrome plated or brass finish) with a port located between the cartridges. Maximum working pressure 10.0 bar. Maximum operating temperature 85°C.
‘Polytank’ wholesome water kit for use with water storage cisterns for domestic purposes. The products have black plastic bodies and consist of a warning pipe elbow incorporating a (white plastic) screen, breather incorporating a (white plastic) screen, vent pipe incorporating a (white plastic) screen, dip tube, plastic washer and backplate. Cold water use only.
Range of ceramic cartridge headworks incorporating NBR ‘O’ rings and silicone seals. For insertion into specifically dimensioned tap assemblies. Maximum working pressure 10.0 bar. Maximum operating temperature 85°C.
Range of quarter turn ceramic disc headworks with metal bodies to be inserted in specifically dimensioned bodies. Maximum working pressure 17.0 bar. Maximum operating temperature 85°C.
Range of ceramic disc diverter cartridges incorporating plastic bodies for use in specifically dimensioned bodies. Maximum working pressure 10.0 bar. Maximum operating temperature 85°C.
Manual click type cartridge headwork with plastic body. EPDM seals and plastic strainer for insertion into specifically dimensioned bodies. Maximum working pressure 10.0 bar. Maximum operating temperature 70ºC.
Range of ceramic disc diverter cartridges with plastic bodies and silicon ‘O’-rings, for insertion into specifically dimensioned bores. Maximum working pressure 16.0 bar. Maximum operating temperature 85°C.
Range of single hole, single outlet (fixed) combination tap assemblies with brass bodies (various finishes), incorporating a ceramic cartridge headwork with a single lever operating member. The spout outlet has a plastic aerator and model 31 531 XXX is supplied with a pop-up waste. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.
Wall mounted single-hole, single outlet, fixed, combination tap assembly with a brass body in a variety of finishes (See models). Incorporating a ceramic disc headwork with a dome type operating member. The temperature is controlled separately via a rotary ceramic cartridge headwork that can also be used as a shut off with a dome type operating member. The inlets to the tap incorporate an approved check valve cartridge; however, the complete product has not been fully tested to demonstrate it provides backflow protection. The spout outlet incorporates a plastic aerator and plastic flow regulator. Maximum working pressure 10 bar. Maximum working temperature 60°C.
Range of single hole, single outlet (fixed) combination tap assemblies incorporating brass bodies (various finishes), ceramic cartridge headworks with single lever operating members. The spout outlets incorporates a plastic aerator. Models 100121306, 100121305 & 100123629 are supplied with lever operated pop-up waste. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.
Range of single hole, single outlet (fixed) combination tap assemblies (chromium plated brass), incorporating a ceramic cartridge headwork with a single lever operating member. The spout outlet incorporates a plastic aerator. The BC428AA and BC430AA models are supplied with a pop-up waste. The products are supplied with loose ⅜” BSP (M) x 15mm compression adaptors for installation on each inlet. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.
Range of floor standing single hole, single outlet (fixed) combination tap assemblies (chromium plated brass), incorporating a ceramic cartridge headwork with a single lever operating member. The spout outlet incorporates a plastic aerator. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.
Range of single hole, single outlet (fixed) over the rim (swivel nozzle) bidet combination tap assemblies with brass bodies (various finishes), incorporating a ceramic cartridge headworks and single lever operating members. The spout outlet incorporates a plastic aerator and the product is supplied with a lever type pop-up waste. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.
Range of single hole, single outlet (fixed) combination tap assemblies (brass bodies, various finishes - see model), incorporating a ceramic cartridge headwork with a single lever operating member. The spout outlet incorporates a plastic aerator. The products can be supplied with waste outlets (see models). Maximum working pressure 10.0 bar. Maximum operating temperature 65°C.
Non-metallic materials and components comply with BS6920 at 70°C
Single hole, single outlet (swivel) combination tap assembly (chromium plated brass), incorporating quarter turn ceramic disk headworks with single leaver operating members. The spout outlet incorporates a plastic aerator. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.
Range of single hole, single outlet (swivel) combination tap assemblies with brass bodies (various finishes), incorporating a quarter turn ceramic disc headworks with single leaver operating members. The spout outlet incorporates a plastic aerator. Maximum working pressure 5.5 bar. Maximum operating temperature 60°C.
Range of wall mounted, two-hole, single outlet (fixed) concealed combination tap assemblies (chromium plated brass) incorporating a ceramic cartridge headwork with single lever operating members. The spout outlet incorporates a plastic aerator. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.
Range of wall mounted, two hole, single outlet (fixed) combination tap assemblies (chromium plated brass or stainless steel), comprising of a concealed rough in set with a brass body and a variety of separate trim sets incorporating a ceramic cartridge headwork with a dome type or single lever operating member and a spout outlet. The spout outlet incorporates a plastic aerator. The products are supplied with click type (click clack) waste. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.
Range of two-hole, single outlet (fixed) combination tap assemblies (chromium plated brass), incorporating quarter turn ceramic disc headworks with single lever operating members or non-rising spindle headworks with dome type operating members (922036 model only) and a self-cancelling diverter to shower outlet. The spout outlet incorporates a plastic flow straightener. The 922308 and 922317 models are also supplied with an optional plastic aerator. The products are supplied with a shower hose and handset and metal back nuts. Maximum working pressure 6.0 bar. Maximum operating temperature 60°C.
Two-hole, single outlet (fixed) combination tap assembly (chromium plated brass), incorporating quarter turn ceramic disc headworks with single lever operating members and a self-cancelling diverter to shower outlet. The spout outlet incorporates a plastic flow straightener. The product is supplied with a shower hose and handset and metal back nuts. Maximum working pressure 6.0 bar. Maximum operating temperature 60°C.
Range of three hole, single outlet (fixed) combination tap assemblies with brass bodies (chrome plated) incorporating quarter ceramic disc headworks and various operating members (see model). The spout outlet incorporates a plastic aerator. The product is supplied a click type waste and stainless steel braided EPDM lined flexible hose assemblies for connecting the side body headworks and the spout junction. Maximum working pressure 5.5 bar. Maximum working temperature 60 °C.
Range of three-hole, single outlet (fixed) combination tap assemblies (chrome plated brass). Incorporating a quarter turn ceramic disc headwork, and dome type operating members (model RAKPER3011C) or cubed type operating members (model RAKPES3011C). Supplied with stainless steel braided EPDM lined hoses, intended for connection between the valves and the spout assembly The spout outlet incorporates a plastic aerator. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.
Range of three hole, single outlet (fixed) combination tap assemblies, brass bodies (various finishes) incorporating quarter turn ceramic disc headworks with various styles of operating members. The spout outlet incorporates a plastic aerator and is connected to the headworks via stainless steel braided EPDM lined hose assemblies. The product is supplied with either a lever type pop up (HIRONDELLE models) or click type waste (ICON-X & CORVAIR models). Maximum working pressure 3.5 Bar. Maximum operating temperature 60°C.
Range of wall mounted four-hole, single outlet, fixed, bath shower mixers (chromium plated brass) incorporating a ceramic disc diverter headwork controlling the flow to 2 outlets. The temperature is controlled independently via a thermostatic cartridge with a manual override button. The RAKPES3306C model has cube type operating members and the RAKPER3306C model has dome type operating members. The spout outlet incorporates a plastic aerator. Maximum working pressure 5.0 Bar. Maximum operating temperature 60°C.
Range of basin spout outlets with brass bodies (various finishes), the outlet incorporates either a metal aerators, plastic aerators or open outlet (depending on model). Maximum working pressure 3.5 bar. Maximum operating temperature 60°C
Range of wall mounted spout outlets with a chromium plated brass bodies and NBR ‘O’-rings. The outlets incorporate a plastic aerator. Maximum operating temperature 85°C.
Range of expansion vessels with EPDM membrane and stainless steel flange connections. Maximum working pressure of 10.0 bar. Maximum operating temperature 100°C.
‘Comisa’ range of brass bodied press-fit and threaded fittings for use with `Comisa’ (PE-RT/AL/PE-LMD) multi-layer pipe. Maximum working pressure 10.0 bar. Maximum operating temperature 95°C.
>B< Range of copper push-fit fittings for use with copper tube manufactured to EN 10226-1. Maximum working pressure 16.0 bar. Maximum operating temperature 85°C.
Boss Range of brass, chrome plated brass or DZR brass compression fittings for use with copper pipe only. Maximum working pressure 16.0 bar. Maximum operating temperature 85°C.
Range of brass, chrome plated brass or DZR brass compression fittings for use with copper pipe only. Maximum working pressure 16.0 bar. Maximum operating temperature 85°C.
Range of press-fit end connectors (gunmetal bodies) for use with copper pipe manufactured to BS EN 1057. Maximum working pressure 16.0 bar. Maximum operating temperature 99°C.
VSH XPRESS Range of copper press fittings with EPDM rubber ‘O’-rings for use with copper pipe (manufactured to EN 1057). Maximum working pressure 16.0 bar. Maximum operating temperature 85°C.
‘Xpress’ range of press fit fittings with copper or brass bodies and EPDM ‘O’-rings. For use with copper tube manufactured to EN1057. For above ground ground use only. Maximum working pressure 16.0 bar. Maximum operating temperature 100°C.
‘Endex’ range of copper alloy and copper end feed fittings for use with copper pipe. For above ground use only. Maximum working pressure 16.0 bar. Maximum operating temperature 99°C.
Center Brand range of brass and copper end feed fittings for use with copper pipe. For above ground use only. Maximum working pressure 16.0 bar. Maximum operating temperature 99°C.
Range of under-sink, electrically heated vented water heaters (cased and insulated). Maximum operating temperature 98˚C
Range of under-sink, electrically heated vented water heaters (cased and insulated). Maximum operating temperature 98˚C
Range of under-sink, electrically heated vented water heaters (cased and insulated). Maximum operating temperature 98˚C
Range of wall hung, gas-fired condensing combination boilers providing domestic hot water via a plate heat exchanger. The pressurised central heating system incorporates an expansion vessel and pressure relief valve set at 3.0 bar. The supplies to both domestic hot water and primary are controlled via spherical valves. The primary circuit has a maximum working pressure of 2.5 bar. The secondary circuit has maximum working pressure of 10.0 bar. Maximum supply temperature is 60°C. Maximum operating temperature of secondary circuit is 85°C.
Range of gas fired condensing combination boilers providing domestic hot water via a plate heat exchanger. The cold inlet incorporates an angled spherical valve with a brass body, chromium plated brass ball and a lever operating member. The primary circuit incorporates an expansion vessel, isolation valves on flow and return, drain valve and a pressure relief valve set at 3.0 bar. Maximum working pressure of the primary circuit is 2.5 bar. Maximum working pressure of the secondary circuit is 10.0 bar. Maximum operating temperature for the secondary circuit is 55˚C. Cold supply only.
Greenstar Heatslave II range of floor standing oil-fired condensing combination boilers providing domestic hot water via a plate heat exchanger and pressurised central heating system, which incorporates an expansion vessel and pressure relief valve set at 3.0 bar. The cold water inlet incorporates a screwdriver operated spherical valve followed by a plastic flow regulator inserted within the pipework. Maximum working pressure: Primary circuit 2.5 bar. Secondary circuit 10.0 bar. Maximum operating temperature 82°C.
Range of air cooled ice making machines . Inlet is controlled via solenoid valve. Maximum working pressure 5.5 bar. Cold water use only.
‘Aquila V4 C1’ range of water meters (brass or bronze bodies) with a plastic working chamber, flow regulator and impellor, and either NBR or EPDM ‘O’-rings. The products are supplied with loose NBR/fibre flange gaskets. Maximum working pressure 16.0 bar. Cold water use only.
Aquila V5 range of water meters with black epoxy coated cast iron bodies, plastic turbines, fibre/NBR flange gaskets and either NBR or EPDM ‘O’-rings. Maximum working pressure 16.0 bar. Cold water use only.
Range of ultrasonic water meters with brass bodies incorporating EPDM ‘O’-rings. The inlets incorporate a plastic strainer. The DN15 X 165mm and DN20 X 190mm models incorporate a non-return valve on the outlet. Maximum working pressure 16.0 bar. Maximum operating temperature 50°C.
Range of single-jet water meters with brass bodies and a plastic strainer on the inlet. Maximum working pressure 16.0 bar. Maximum operating temperature 90°C.
Range of in-line water meters with brass bodies and plastic inlet filters. Maximum working pressure 16.0 bar. Maximum operating temperature 50°C (SJ & ELECTO-SJ models) Maximum operating temperature 30°C (AP VARIO and AP RADIO models)
Range of ‘Resident Valves’ with a DZR brass body consisting of water meter manifold, an isolation valve on the inlet, a pressure reducing valve (adjustable between 1.5 and 6.0 bar) and 2 non-return valves which are located on the outlet of the water meter manifold. The ‘Plus’ models are also supplied with an isolation valve on the outlet, which incorporates a drain tap. Maximum supply pressure 16.0 Bar. Cold water above ground use only.
Page 4 of 46
We use cookies to give you the best possible experience with WRAS. Some are essential to provide website functions and ensure the website is secure. We also use cookies to help us understand how people use the site and to make improvements. Click "Accept All" to enable recommended settings or click "Manage cookies" to adjust your settings. For more details, see our Cookie Policy.