Range of shower handsets with plastic bodies incorporating an integral filters. The inlet incorporates a combined washer and a strainer, plastic flow regulator and an approved check valve cartridge, however, the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum operating temperature 60°C
Wall mounted overhead shower outlets with (chrome plated) brass bodies and EPDM ‘O’-rings. Maximum operating temperature 65°C.
Range of shower arms, ceiling arms, water intakes and wall mounted outlet brackets (all models excluding INOX are chrome plated brass, INOX models are stainless steel). Maximum operating temperature 60.0°C
Overhead shower outlet with a chrome plated plastic body. The inlet incorporates a stainless-steel strainer. Maximum operating temperature 65°C.
Range of in-line `Y` patterned strainers with bronze bodies and stainless-steel strainer. Maximum working pressure 16.0 bar. Maximum operating temperature 100°C. Closed circuit up to 110°C
Range of Y type strainers with blue epoxy coated ductile iron bodies and EPDM ‘O’-rings. Maximum working pressure 25.0 bar. Maximum operating temperature 85°C
Range of flow sensors with brass or plastic bodies (see model). Maximum working pressure 16.0 bar. Maximum operating temperature 90°C.
A range of wall mounted self-closing pillar taps or shower valves (chromium plated brass), incorporating a spring loaded headwork with a dome type operating member. T Maximum working pressure 10.0 bar. Maximum working temperature 60°C.
‘Tempomix 3’ range of self-closing combination tap assemblies (chromium plated brass) with spring loaded headwork controlling both the flow and temperature with a dome type operating member. The spout outlets incorporate a plastic flow straightener. The inlet hoses each incorporate a plastic strainer and a plastic flow restrictor either side of an approved check valve cartridge, however, the complete product has not been fully tested to demonstrate it provides backflow protection. The 794000 and 79400015 models are supplied with ⅜” BSP (M) x ⅜” captive nut inline isolation valves. The 79400015 model is also supplied with a ⅜ BSP (M) x ½” BSP (M) brass adaptor. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.
Range of TPE and TPS lined flexible hose assemblies incorporating NBR ‘O’-rings and various end connections. Maximum operating temperature 60°C.
Range of stainless steel braided HDPE lined flexible hose assemblies incorporating EPDM ‘O’-rings and/or washers depending on end connection. Maximum working pressure 10.0 bar. Maximum operating temperature 85°C
Range of stainless steel or nylon braided PEX lined flexible hose assemblies. Maximum working pressure 10.0 bar. Maximum operating temperature 85°C.
Range of stainless-steel braided EPDM lined flexible hose assemblies with various end connections. SCFA models incorporate a spherical valve. Maximum working pressure 16.0 bar. Maximum operating temperature 85°C.
Range of stainless-steel braided EPDM lined flexible hose assemblies incorporating EPDM washers and ‘O’-rings, and various end connections, some of which include a brass bodied screwdriver operated spherical valve with chrome plated brass ball (see model). For use with copper pipe (EN 1057) Maximum working pressure 10.0 bar. Maximum operating temperature 85°C.
Range of stainless-steel braided EPDM lined flexible hose assemblies incorporating EPDM washers and ‘O’-rings, and various end connections, some of which include a brass bodied screwdriver operated spherical valve with chrome plated brass ball (see model). For use with copper pipe (EN 1057) Maximum working pressure 10.0 bar. Maximum operating temperature 85°C.
Stainless steel braided, silicone lined flexible hose assembly with brass end connections Maximum working pressure 10.0 bar. Maximum operating temperature 90°C.
Mitsubishi EHWT17D-MHEDW indirectly heated stainless-steel unvented storage cylinder consisting of plate heat exchangers. The secondary circuit is factory fitted with a temperature and pressure relief valve set at 7.0 bar and 90˚C. A safety kit (manifold) consisting of an approved single check valve cartridge (verified by test as suitable for backflow protection against Fluid Category 2), strainer, a pressure relief valve set at 6.0 bar and pressure reducing valve set at 3.5 bar. The space heating circuit is factory fitted with a pressure relief valve fitted rated at 3.0 bar and an automatic air vent. A tundish, expansion vessel and filling loop are also supplied. Maximum secondary (wholesome) circuit working pressure: 5.5 bar. Maximum Space heating (primary) circuit working pressure: 2.5 bar. Maximum brine/ambient circuit working pressure: 9.5 bar. Maximum operating temperature 70°C
‘Comet’ combination units consisting of a cased and insulated stainless steel unvented hot water storage cylinder. The cylinder primary circuit is fitted with an in-line electrical heater which supplies the heat source to the secondary water via a stainless-steel coil, and the heat source to the central heating circuit directly. The cylinder is factory fitted with a temperature and pressure relief valve, pre-set at 7.0 bar 90 degrees. The unit is supplied with an inlet control group containing a check valve cartridge, verified by test (suitable for backflow protection against Fluid Category 2), pressure reducing valve set at 3.0 bar and an expansion relief set at 6.0 bar. An expansion vessel is factory fitted to both the secondary and primary circuits within and is positioned inside the casing. The primary circuit also incorporates a circulating pump and pressure relief valve which is set at 3.0 bar. Maximum secondary working pressure 5.5 Bar Maximum Primary working pressure 2.5 Bar Maximum operating temperature 65.0 °C
Range of “MEGAAIR” bubble top indirect and direct single coil unvented storage cylinders. The secondary circuit is factory fitted with a temperature and pressure relief valve set at 10.0 bar@90˚C. A safety kit (manifold) consisting of a single check valve assembly, verified by test (suitable for backflow prevention against fluid category 2), strainer, an expansion relief valve set at 8.0 bar and a pressure reducing valve set at 3.0 bar and a tundish is also provided. Alternative inlet control group and temperature and pressure relief valve added January 2023. Maximum working pressure: Secondary circuit: 7.5 bar. Primary circuit: 6.0 bar.
Non-metallic materials and components comply with BS6920 at 65°C
Vacuum relief valve with a DZR brass body. Maximum working pressure 16.0 bar. Maximum operating temperature 99˚C
Range of deck mounted, manually operated, concealed blending valves with chromium plated brass bodies and either brass or stainless-steel trim (see model). The product incorporates a ceramic cartridge headwork with a single lever operating member. The product is supplied with a stainless steel braided PEX lined flexible hose assembly incorporating a ¾” captive nut end connection for installation on the outlet. Maximum working pressure 10.0 bar. Maximum operating temperature 65°C.
Range of electronic, thermostatic mixing valves which incorporate a solenoid valve on the inlet and various outlet configurations dependant on model. All models are supplied with a user interface that controls flow and temperature. The inlets of models 1.1503.678, 1.1503.682, 1.1503.690, 1.1503.698 & 1.1621.099 incorporate a single check valve cartridge, however, the complete product has not been fully tested to demonstrate it provides backflow protection Model 1.1503.702 – Rada Sense W KIT T3 Washbasin is supplied with a wall mounted spout outlet. Model 1.1503.706 – Rada Sense S KIT T3 Shower is supplied with a fixed shower outlet. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C
Range of wall mounted thermostatic bar shower valves incorporating a thermostatic cartridge controlling the temperature with a dome operating member incorporating a manual override button. The flow to the handset or overhead shower is via a ceramic disc headwork with a dome operating member. Inlets Incorporate approved check valve cartridges, however, the complete product has not been fully tested to demonstrate it provides backflow protection. RRK models are also supplied with shower hose, handset, overhead shower head and riser rail. Maximum working pressure 5.0 bar. Maximum operating temperature 65ºC.
Range of T type thermostatic blending valves with (nickel plated) DZR brass bodies. The inlets incorporate a stainless-steel strainer and single check valve cartridge verified by test (suitable for backflow protection against Fluid Category 2) Models HEAT160030 & HEAT160035 also incorporate a servicing valve at the inlet. Maximum working pressure 5.0 bar. Maximum operating temperature 85°C
Range of wall mounted thermostatic blending valves with brass bodies (chrome plated), incorporating two way diverter valves controlling the flow with dome type operating members. Temperature is controlled independently via a thermostatic cartridge with a dome type operating member. The inlets incorporate approved check valve cartridges, however, the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum working pressure 10.0 bar. Maximum operating temperature 85°.
Range of concealed, wall mounted, thermostatic mixer valves with brass bodies (various finishes) with 1 - 6 outlets. Flow is controlled to each outlet by ‘detent’ (push to on push to off) headworks. The temperature is controlled independently via a thermostatic cartridge with a dome type operating member that incorporates a manual override button. The inlets incorporate a combined plastic washer and stainless steel strainer, as well as an approved single check valve cartridge, however, the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.
Range of wall mounted thermostatic blending valves (chromium plated brass) incorporating a quarter turn ceramic disc headwork. The temperature is controlled independently via a thermostatic cartridge incorporating a manual override button. The inlets incorporate a stainless steel strainer and an approved check valve cartridge, however, the complete product has not been fully tested to demonstrate it provides backflow protection. Model SL-T50004BW has a maximum working pressure of 10.0 bar. All other models have a maximum working pressure of 6.0 bar. Maximum operating temperature is 85°C.
Range of wall mounted, exposed bar type thermostatic blending valves (chromium plated brass) incorporating a quarter turn ceramic disc headwork controlling the flow with a dome operating member and manual override button. The temperature is controlled by a thermostatic cartridge with dome type operating member and manual override button. Both inlets incorporate a stainless-steel strainer and single check valve cartridge (however, the complete product has not been fully tested to demonstrate it provides backflow protection). Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.
Range of wall mounted, bar type thermostatic blending valves (chromium plated brass) incorporating a 2-way manual diverter valve controlling and diverting the flow between an overhead shower and a shower outlet with dome type operating members, model (34458892) is supplied with cross-top operating members. The temperature is controlled independently via a thermostatic cartridge with a dome type operating member incorporating a manual override button. Both inlets incorporate a stainless-steel strainer and an approved check valve cartridge, however, the complete product has not been fully tested to demonstrate it provides backflow protection. The inlet to the overhead shower incorporates a stainless steel strainers and flow regulator. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C
Range of wall mounted thermostatic blending valves with brass bodies (various finishes), incorporating a quarter ceramic disc headwork controlling the flow with dome type operating member. Temperature is controlled via a thermostatic cartridge with dome type operating member incorporating a manual override button and a push button manual diverter to shower outlet. Both inlets incorporate a stainless-steel strainer and an approved check valve cartridge, however, the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum working pressure 5.0 bar. Maximum operating temperature 65°C
Range of wall mounted, bar type thermostatic blending valves (chromium plated brass) incorporating a quarter turn ceramic disc headwork controlling the flow with a dome or cube operating member incorporating a manual override button. The temperature is controlled by a thermostatic cartridge with dome or cube type operating member incorporating a manual override button. Both inlets incorporate a stainless-steel strainer and single check valve cartridge (however, the complete product has not been fully tested to demonstrate it provides backflow protection). Maximum working pressure 10.0 bar. Maximum operating temperature 65°C.
Range of wall mounted, bar type thermostatic blending valves (chromium plated brass) incorporating a quarter turn ceramic disc headwork controlling the flow with a lever operating member. Temperature is controlled independently via a thermostatic cartridge with a single lever operating member. Both inlets incorporate an eccentric isolation valve, a stainless-steel strainer and an approved check valve cartridge, however the complete product has not been fully tested to demonstrate it provides back flow protection. The shower outlet connection on the main valve incorporates a flow restrictor (H9741 model only). Maximum working pressure 5.0 Bar. Maximum operating temperature 60°C
Range of lugged and wafer type butterfly valves with blue epoxy coated bodies, incorporating EPDM rubber ‘O’-rings and seat, and either a bronze (AB2), stainless steel (CF8 & CF8M) or blue epoxy coated ductile iron (DI) disc. Maximum working pressure 25.0 bar. Maximum operating temperature 85°C.
Range of wafer or lugged butterfly valves incorporating blue epoxy coated ductile iron bodies, EPDM seats and stainless steel or ductile iron discs (nickel plated). The products are supplied with either bare shaft or with lever or gear operating members. Maximum working pressure 16.0 bar. Maximum operating temperature 100°C.
Manual diverter valve controlling the flow to a hand shower or overhead shower, housed within a brass body (various finishes). Incorporating a stainless-steel strainer and approved check valve cartridge on the inlet, however, the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum operating temperature 70°C.
Range of pressure reducing valves with DZR brass bodies, integral stainless steel strainer, and EPDM ‘O’-rings and membrane. The oulet pressure is adjustable between 1.5 bar and 6.0 bar. Maximum inlet supply pressure 25.0 bar. Maximum operating temperature 70°C.
Range of pressure reducing valves with DZR brass bodies, internal stainless steel filter, EPDM ‘O’-rings and diaphragm. Adjustable outlet pressures between 1.0 and 6.0 bar or 1.0 and 12.0 bar (see model). Maximum inlet supply pressure 25.0 bar. Maximum operating temperature 80°C.
Range of pre-set angled pressure relief valves for use on primary closed circuits, incorporating DZR brass bodies, EPDM diaphram and EPDM or NBR ‘O’-ring. For maximum working pressure please refer to model. Maximum operating temperature 99°C.
Range of normally closed solenoid valves with brass bodies, stainless steel spring, EPDM seal and diaphragm. Maximum working pressure 9.80665 bar. Maximum operating temperature 85°C.
A range of screwdriver operated spherical valves with brass bodies and brass ball, EDPM ‘O’-rings and fibre washers. Maximum working pressure 16.0 bar, Maximum working temperature 85°C.
Range of inline and angled screwdriver or lever handle operated spherical valves with (chromium plated) brass bodies, chromium plated brass ball, NBR ‘O’-rings. For use with copper pipe manufactured to EN 1057 Maximum working pressure 16.0 bar at 30°C and 5 bar at 99°C Maximum working pressure 6.0 bar. Maximum operating temperature 90°C (model TX480 only)
Range of spherical valves incorporating nickel plated brass bodies, chrome plated brass balls & Tee type operating member. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.
ISIS range of single lever and T type operated spherical valves with DZR brass body and ball (chrome plated), and PTFE seals. Maximum working pressure 40.0 bar (¼”, 3/8”, ½”, ¾”, 1”, 1 ¼”, 1 ½”, & 2” models) Maximum working pressure 10.0 bar (2 ½”, 3” & 4” models) Maximum operating temperature 100°C
Range of spherical valves with brass bodies, brass ball, PTFE washer and seats, incorporating a butterfly handle operating member (R254 models) or single lever operating member (R254DL models). Maximum working pressure 42.0 bar (¼ - ½” models). Maximum working pressure 35.0 bar (¾” - 2” models). Maximum operating temperature 99°C.
Range of gate valves incorporating blue epoxy coated ductile iron bodies and EPDM coated ductile iron wedges. The valves are operated via a non-rising spindle with a hand wheel operating member or key and bar operating members (see model). Maximum working pressure 16.0 bar.
Non-metallic materials and components comply with BS6920 at 85°C
Range of regulating valves with blue epoxy coated ductile iron bodies incorporating EPDM gaskets and hand wheel operating member. Maximum working pressure 25.0 bar. Maximum operating temperature 85°C.
'M90 POM Particle'. White coloured (opaque), injection moulded POM material. For use with water up to 65°C.
'FC941'. Black coloured, injection moulded, carbon graphite bearing. For use with water up to 85°C.
'Rapal Light C795' disc. White coloured, compression moulded, ring shaped ceramic gliding disc. For use with water up to 85°C.
'Polyurea FA 1044'. Factory applied, two-component, beige coloured polyurea coating. Mix parts A and B in a 1:1 volume ratio apply as per manufacturer's TDS '07/2015 Rev.00'. Cure for 96 hours@25°C. For use with water up to 23°C. This material is only approved for the mixing and curing conditions that appear on the approval. If the mixing and/or curing conditions are varied from those specified on the approval then the material is not covered by the scope of the approval.
Page 25 of 81
We use cookies to give you the best possible experience with WRAS. Some are essential to provide website functions and ensure the website is secure. We also use cookies to help us understand how people use the site and to make improvements. Click "Accept All" to enable recommended settings or click "Manage cookies" to adjust your settings. For more details, see our Cookie Policy.