Range of press fittings and pipe. Fittings incorporate EPDM ‘O’-rings Maximum working pressure 10 bar. Maximum operating temperature 95°C
Inoxpres range of stainless-steel crimp fittings with EPDM ‘O’-rings and gasket for use with Inoxpres stainless-steel tube (1.4404 AISI 316L or 1.4521 AISI 444 – annealed or not-annealed). The connection is created by using a pressing tool. For above and below ground use. Maximum working pressure: 16.0 bar. Maximum operating temperature: 95°C.
Instantor Metric Copper Press Range crimp fittings with EPDM ‘O’-rings for use with copper tube manufactured to EN 1057. The joints are achieved by means of a crimping tool. For above ground use. Maximum working pressure: 16.0 bar. Maximum operating temperature: 85°C
Range of press copper crimp fittings with EPDM ‘O’-rings for use with copper tube manufactured to EN 1057. The joints are achieved by means of a crimping tool. For above ground use. Maximum working pressure: 16.0 bar. Maximum operating temperature: 85°C
Range of press fittings with a brass body and EPDM ‘O’-rings for use with copper pipe manufactured to EN1057:2006 +A1:2010 seamless round copper tube R250. Joints are achieved using a specialist press fitting tool. Maximum working pressure 16.0 bar. Maximum operating temperature 85°C.
Range of AIS tin-plated brass and PPSU press fit fittings for use with MULTIPIPE multi layered PE-RT/AL/PE-RT pipe. Maximum working pressure 10.0 bar. Maximum operating temperature 70°C.
Range of MULTITUBO tin-plated brass and PPSU press fit fittings for use with MULTITUBO multi layered PE-RT/AL/PE-RT pipe. Maximum working pressure 10.0 bar. Maximum operating temperature 70°C.
Range of ‘NiroSan’ stainless-steel crimped fittings incorporating EPDM ‘O’ Rings, for use with ‘NiroSan’, ‘NiroSan SF’ & ‘NiroSan -ECO’ stainless-steel pipe (all manufactured to EN10312). The fittings and pipe are assembled using a crimping tool with either ‘M’ (15-108mm), ‘V’ (15-54mm) or ‘SA’ (15-108mm) crimping profiles. For above ground use only. Maximum working pressure: 16 Bar. Maximum operating temperature: 99°C.
IDC ‘BDGxxx’ range of press fittings with brass or nickel plated brass bodies (see model) incorporating EPDM ‘O’-rings and stainless steel crimp sleeves for use with PEX/AL/PEX multilayer pipe (manufactured to EN ISO 21003). The BDG241 and BDG257 prefix models incorporate an EPDM gasket on the captive nut end connection. Pressfit jointing is achieved by either a U or TH crimping profile. Compression connections are for use with copper pipe 12-28mm (manufactured to EN1057) or Irish copper pipe 14.7-27.4mm (manufactured to EN1057). For above ground use only. Maximum working pressure 10.0 bar. 20, 25 & 26mm pressfit sizes cold water use only. Threaded, compression and 16 & 32mm pressfit sizes maximum operating temperature 95°C. From June 2025: The 20, 25 & 26mm pressfit sizes (TH profile only) maximum operating temperature 95°C.
"Yi Sin" Range of press fittings with a stainless steel body and EPDM ‘O’ rings for use with stainless steel 316L pipe manufactured to EN10312. For above ground use only. Maximum working pressure 16.0 bar. Maximum operating temperature 85°C.
Range of ‘Isiflo Sprint’ push fit fittings for use with PE100 pipe (manufactured in accordance with EN 12201), for above and below ground use. Isiflo Sprint Family fittings can be installed with seal liners, support liners and without any liner. Maximum working pressure 16 bar. Cold water use only.
SANHA Press Series 6000 & 16000 and PURAPRESS Series 8000 of press-fit fittings with copper (6000), bronze (8000) and chrome plated copper (16000) bodies and EPDM `O`-rings. For use with copper pipe manufactured in accordance with BS EN1057. Maximum working pressure 16.0 bar. Maximum operating temperature 99°C.
Allpex range of end feed capillary fittings and brazing fittings for use with copper tube (manufactured to BS EN 1057). EG fittings have gunmetal bodies, ED fittings have DZR brass bodies & EB fittings have brass bodies. For above ground use only. Maximum working pressure: 6mm – 34mm 25Bar, 34mm -54mm 25Bar, 54mm – 108mm 16Bar, 108mm – 159mm 5 Bar. Maximum operating temperature 30°C
Range of copper end feed solder fittings for use with copper tube (EN1057). For above and below ground use. Maximum working pressure for sizes 8mm to 54mm is 25.0 bar. Maximum working pressure for sizes above 54mm is 16.0 bar. Maximum operating temperature 99°C.
Range of wall mounted combination boilers providing domestic hot water via a plate heat exchanger and pressurised central heating system. The primary circuit incorporates a pressure relief valve set at 3.0 bar and an expansion vessel. The products are supplied with isolation valve on both the DHW and CH circuits. The secondary circuit (DHW) incorporates a plastic flow restrictor and stainless-steel strainer. Some models (see model section) are supplied with a filling loop assembly consisting of an in-line isolation valve, an in-line double check valve assembly which incorporates an isolation valve. Maximum working pressures: DHW: 10.0 Bar CH: 2.5 Bar Maximum operating temperature: DHW: 65.0°C CH: 85.0°C
Range of vertical submersible multistage pumps with either threaded or flanged end connections. Maximum operating temperature 23°C. Open outlet use only.
Range of horizontal or vertical multi-stage pumps with a stainless-steel body (HM models) or cast iron body with blue coloured cationic resin coating (VM models), incorporating either plastic or stainless-steel impellers (see model), stainless steel sleeve, EPDM gaskets and seals. Maximum working pressure 10.0 bar / 16.0 bar (see models). Cold water use only.
Range of electronic pressure switches housed in a plastic body with a ceramic sensor and NBR gaskets and/or ‘O’-rings. The U480015 and U480016 models incorporate a spring-loaded plastic flow restrictor. Maximum working pressure 12.0 bar. Cold water only.
Range of wall mounted hose union taps (brass body or DZR brass body - see model) incorporating a non-rising spindle headwork with a ‘T’-type operating member. The MBHU04DCV model incorporate two approved single check valve cartridges, however the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum working pressure 14.0 Bar. Maximum operating temperature 85°C.
Range of wall mounted, self-closing, knee operated tap assemblies (chromium plated brass), incorporating spring loaded headwork with single lever type operating member. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.
Range of stainless-steel interlocked shower hoses and shower hose extension pieces (smaller length versions) incorporating PE/EPDM and PEX inner tube materials. Available with various surface finishes and end connectors. For further details see model section. Maximum working pressure open outlet use. Maximum operating temperature 85.0°C
Range of PE lined, nylon braided (black or grey) flexible hose assemblies. The hoses are available with a variety of end connections with different finishes (see model). Maximum operating temperature 85°C. Open outlet use only.
Range of nylon braided (DG50E model series) or stainless steel braided (DG10E model series), EPDM lined flexible hose assemblies with a variety of end connections (see models for full breakdown), including EPDM washers and ‘O’-rings where applicable. Some models are supplied with screwdriver operated isolation valves (see model list). All compression and push-fit fittings are to be used with copper pipe (manufactured to BS EN 1057). Maximum working pressure: 16 bar. Maximum operating temperature: 85°C.
Range of stainless steel or brass double interlocking, TPS lined flexible hose assemblies (various finishes) incorporating EPDM gaskets. Maximum operating temperature 60°C. Open Outlet Use Only
Range of stainless-steel or nylon braided PEX lined hoses, incorporating EPDM O-ring or gaskets. Maximum working pressure 10.0 bar. Maximum operating temperature 85°C.
Range of wall mounted, concealed, manual blending shower valves with brass bodies (various finishes), incorporating a ceramic cartridge headwork and various single lever operating members. The product is also supplied with ¾” BSP (M) x ½” BSP (F) adaptors. Maximum working pressure 10.0 Bar Maximum operating temperature 70.0°C
Range of T-type thermostatic mixing valves with chrome plated DZR brass bodies and EPDM ‘O’-rings incorporating a thermostatic cartridge controlling the temperature. Each inlet incorporates a stainless steel strainer. The inlets of the 252714 and 252713 models incorporate a check valve cartridge, verified by test (suitable for backflow protection against Fluid Category 2). Maximum working pressure 10.0 bar. Maximum operating temperature of 85°C.
Wall mounted thermostatic bar shower mixers (chrome plated brass body) incorporating a 2 way ceramic disc diverter headwork controlling the flow between the overhead shower and handset with either a dome or cube type operating member. The temperature is controlled independently via a thermostatic cartridge incorporating a manual override button with either a dome or cube type operating member. Each inlet incorporates a stainless-steel strainer and an approved check valve cartridge; however, the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum working pressure 3.0 Bar. Maximum operating temperature 60°C.
Range of T-type thermostatic mixing valves with brushed chrome plated DZR brass bodies for use with copper pipe (manufactured to BS EN 1057). The inlets of the PEG prefix models incorporate a check valve cartridge verified by test (suitable for backflow protection against Fluid Category 2). The inlets of the TX prefix models incorporate an approved check valve cartridge however, the complete product has not been fully tested to demonstrate it provides backflow protection. UA & UAX suffix models incorporate isolation valves on each inlet, which includes a cold through connection on the UAX models. All inlets incorporate stainless steel strainers. Maximum working pressure 10.0 bar. Maximum operating temperature 85°C.
Range of wall mounted, concealed, thermostatic shower blending valves (brass bodies – various finishes), The flow is controlled via a 2 way manually operated diverter to the shower outlets. Temperature is controlled via a thermostatic cartridge incorporating a manual override button. The trim sets are provided with dome type operating members. The inlets incorporate an approved single check valve cartridge, however, the complete product has not been fully tested to demonstrate it provides backflow protection. The product is supplied with a shower hose and handset. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.
Range of piston type float operated inlet valves with brass bodies. The valves discharge from a downwards atmospheric discharge arrangement on the underside of the body. Maximum working pressure: 3.0 (1MFVLP104 models only) or 14.0 Bar (all other models) Cold water use only.
Range of flow control valves with epoxy coated ductile iron bodies. Auxiliary components include a needle valve, pressure reducing pilot valve and isolation valves. Maximum supply pressure 16.0 bar. Outlet pressure setting is adjustable in the range 0.6 to 1.2 bar. Maximum operating temperature 65°C.
Range of pilot operated basic valves, main body only, with epoxy coated ductile iron bodies. Maximum operating pressure 16.0 bar. Maximum operating temperature 65°C.
Range of pilot operated pressure reducing valves with epoxy coated ductile iron body (either blue or red/brown). The valve has an adjustable pressure reducing facility controlled via a pilot valve, with auxiliary components including stainless steel tubing and fittings, nickel plated brass spherical valves and a ‘Y’-pattern strainer. DN600-DN1400 sizes also incorporate a needle valve and a swing gate valve. Maximum inlet supply pressure 16.0 bar. Outlet pressure setting is adjustable in the range of 1.0 – 7.2 bar. Maximum operating temperature 65°C.
Range of pressure relief valves with plastic bodies and EPDM diaphragms and ‘O’-rings, Factory pre-set at 3.0 bar. Maximum operating temperature 110°C.
Range of angled valves with brass bodies (some models chrome plated). Maximum working pressure 10 bar. Maximum operating temperature 65°C
‘Satefy group’ with a brass inlet and a DZR brass body which incorporates a lever operated spherical valve, followed by an approved check valve cartridge, verified by test (suitable for backflow protection against Fluid Category 2) and a plastic bodied pressure relief valve (set at 6.0 bar). The product incorporates a test point. The compression connections are for use copper pipe (manufactured to EN 1057). Maximum working pressure 16.0 bar. Maximum operating temperature 85°C.
Range of motorised position pilot operated control valves with epoxy coated ductile iron bodies and stainless-steel pipework and fittings. Maximum operating pressure 16.0 bar. Maximum operating temperature 65°C.
Range of ultraviolet disinfection units with stainless-steel bodies. Maximum working pressure 10.0 bar. Maximum operating temperature 40°C.
Range of UV disinfection units with stainless steel bodies. Maximum working pressure 10.3 bar. Maximum operating temperature 60°C.
'Loctite PC 7255 GN (Green) coating for use with Bonderite M-NT 1455-W primer'. Factory applied, green coloured, two-component epoxy resin coating. In June 2025 ‘LOCTITE PC 7255 GY (Grey) coating for use with BONDERITE M-NT 1455 Primer-W Coating’ was added to the approval. Factory applied, grey coloured, two-component epoxy resin coating. Prime the surface to be coated with the Bonderite primer wipe. Mix and apply as per manufacturer’s TDS dated October 2016. Cure for 7 days@23°C at 45% relative humidity. For use with water up to 85°C. This material is only approved for the curing conditions that appear on the approval. If the cure conditions are varied from those specified on the approval then the material is not covered by the scope of the approval.
'Edelpoxy FN TM 142'. Factory coloured, red coloured epoxy resin coating consisting of a base and hardener. Mix base and hardener in a 3:1 volume ratio and apply as per manufacturer's IFU 'PCC/ PC 142', dated '10.07.2018'. Cure for 7 days@30°C. For use with water up to 60°C. This material is only approved for the mixing and curing conditions that appear on the approval. If the mixing and/or curing conditions are varied from those specified on the approval then the material is not covered by the scope of the approval.
'LMI.Hygienic HI-Build Epoxy'. Factory applied, two- component, blue coloured epoxy coating. Mix base and hardener in a weight ratio of 100:15 and apply as per manufacturer's instructions 'LMIEP1403032', dated '22/06/2024'. Cure for 2 hours@20°C. For use with water up to 23°C. This material is only approved for the mixing & curing conditions that appear on the approval. If the mix and/or cure conditions are varied from those specified on the approval then the material is not covered by the scope of the approval.
‘Corroless ACO Brush Grades RAL5005 (GB861) and Light Green (GB206)’ (formerly known as 'Acothane Brush Grades Blue & Green'). Site applied, blue or green coloured, two-part polyurethane coatings consisting of an amber coloured, liquid activator and blue or green coloured coating. Mix brush grade and activator in a 3.24:1 weight ratio. Apply as per technical data sheet dated Feb 2020. Cure for 14 days@7°C. For use with water up to 23°C. This material is only approved for the mixing and curing conditions that appear on the approval. If the mix and cure conditions are varied from those specified on the approval then the material is not covered by the scope of the approval.
'Interline 975 White'. Site applied, two-part epoxy coating which can be applied as one coat or three coats. Mix parts A & B in a 2.2:1 and apply as per manufacturer's TDS 'Ref:4236', 'Issue Date: 04/02/2015'. When applied as a single coat, the coating must be cured for 14 days at 10°C. When applied as a three-coat system, the coating must be cured as follows: coat 1 = 24 hours@10 °C, coat 2 = 24 hours@10 °C & coat 3 = 14 days@10 °C. For use with water up to 23°C. This material is only approved for the mixing and curing conditions that appear on the approval. If the mixing and/or curing conditions are varied from those specified on the approval then the material is not covered by the scope of the approval.
'ULTRADUR® B4300 G6 FC AQUA WHITE 25262 & ULTRADUR® B4300 G6 FC AQUA BLACK 15142'. White coloured & black coloured, injection moulded PBT materials. For use with water up to 85°C.
'662016, 662014, 662062 & 662061'. White coloured, PTFE tape manufactured by calendering. For use with water up to 85°C.
'RIAMAXX HR GF40 Xgea14 KTW schwarz'. Black coloured, injection moulded Polyketone material. For use with water up to 85°C.
Range of bottom and side entry BS1212-4 (2016) compact type float operated valves for WC flushing cisterns, delayed or non-delayed fill. The inlet incorporates a strainer. Maximum working pressure - 10 Bar Cold water use only.
Concealed WC dual flushing cistern with a side entry BS 1212-4 (2016) float operated inlet valve providing a Type AG air gap arrangement and a dual flush outlet valve. The flush volume is operated by a two-push button assembly for a 6 or 3 litre flush volume. The cistern is operated by a manual push button and incorporates a servicing valve and flexible hose on the inlet supply. Maximum working pressure – 10.0 bar, cold water use only.
Page 18 of 24
We use cookies to give you the best possible experience with WRAS. Some are essential to provide website functions and ensure the website is secure. We also use cookies to help us understand how people use the site and to make improvements. Click "Accept All" to enable recommended settings or click "Manage cookies" to adjust your settings. For more details, see our Cookie Policy.